Ewig Macao Commercial Offshore THX201 433 MHz Thermo Hygro Sensor User Manual WSU601 THX201 UserManual

Ewig Industries Macao Commercial Offshore Limited 433 MHz Thermo Hygro Sensor WSU601 THX201 UserManual

Users Manual

Download: Ewig Macao Commercial Offshore THX201 433 MHz Thermo Hygro Sensor User Manual WSU601 THX201 UserManual
Mirror Download [FCC.gov]Ewig Macao Commercial Offshore THX201 433 MHz Thermo Hygro Sensor User Manual WSU601 THX201 UserManual
Document ID976228
Application ID5SBLMbOH2st/o7GKW0Dibw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize12.8kB (159950 bits)
Date Submitted2008-07-25 00:00:00
Date Available2008-07-25 00:00:00
Creation Date2008-07-16 15:43:56
Producing SoftwarepdfFactory v1.57 (Windows XP Chinese)
Document Lastmod0000-00-00 00:00:00
Document TitleMicrosoft Word - WSU601&THX201_UserManual.doc
Document CreatorpdfFactory http://www.pdffactory.com
Document Author: cee3

Weather station with 433MHz thermo-hygro sensor and
radio controlled clock
Model: WSU601+THX201
INSTRUCTION MANUAL
Congratulations on your purchase of this new Weather Station. This unique product is
designed for everyday use for the home or office and is a definite asset of great use. To
fully benefit from all the features and understand the correct operation of this product,
please read this instruction manual thoroughly.
FUNCTIONS OF THE WEATHER STATION
This weather station measures the environment of its surrounding area and receives
weather data transmitting from up to five outdoor thermo-hygrometers for temperature
and humidity.
The data is continuously updated to bring you the latest weather information displayed
on the LCD of the receiving unit. Its wireless 433MHz can transmit data over a distance of
50 meters (165 feet) in open space.
FEATURES: MAIN UNIT
A. Air pressure trend arrows
Indicate the trend of air pressure changes
B. Low battery indicator
Shown to indicate the battery in the main unit is low and all displayed information in LCD is
no longer reliable. The user needs to change the batteries at once
C. Weather forecast window
Show weather forecast in animation with snowfall indicator and storm warning indicator
D. Moon phase
The animated running moon phase will pause for 5 seconds in place of current moon
phase.
E. Outdoor remote sensor indicator
Indicates the current outdoor remote sensor signal received. It can display up to 5
different remote sensors, which are placed in 5 different places and within 50-meter
distance from the main unit.
F. Auto scroll indicator
The animated rolling arrow icon is shown to indicate the auto scroll of 5 different remote
channels.
G. Outdoor maximum/minimum indicator
Indicates the maximum/minimum outdoor temperature or humidity is displayed
H. Remote sensor battery low indicator
Appear when the batteries of the remote sensor are running dry and the temperature or
humidity measured by this sensor is no longer reliable. The user must change the batteries
at once.
I. Indoor indicator
Indicates the indoor temperature and humidity are displayed.
J. Indoor maximum/minimum indicator
Indicates the maximum/minimum indoor temperature is displayed.
K. Barometric pressure chart
Shows the barometric pressure trend chart for the past 24 hours.
L. Clock window
Display Clock-Second (HR-MIN-Sec), Clock-Weekday (HR-MIN-Weekday), calendar or
alarm time.
M. Radio reception signal
Indicates the condition of WWVB radio controlled time reception.
N. Alarm on icon
Appears when alarm is activated.
DESCRIPTION OF BUTTONS
WSU601 has 7 major function buttons on top and both edges.
1. [SNOOZE/LIGHT]
Press once to activate the LCD backlight or snooze function.
2. [-]
Press to decrease the calendar date to view the MOON PHASE status of a specific day in
Day-Month-Year (or Month-Day-Year depends on the date format setting).
Press once to decrease the setting in CLOCK, CALENDAR or ALARM setting mode.
3. [CHANNEL]
Select among channel 1, 2, 3, 4, 5 or to enter auto scroll mode.
Press and hold 2 seconds to activate or deactivate the sensor searching mode.
4. [MEMORY]
Toggle to view the Max/Min reading of the Indoor & Remote Temperature/humidity.
Press & hold 2 seconds to clear Indoor & all Remote temperature/humidity memories.
5. [+]
Press once to increase the date to view the MOON PHASE status of a specific day in
Day-Month-Year (or Month-Day-Year depends on the date format setting).
Press once to increase the setting in CLOCK, CALENDAR or ALARM setting mode.
Press & hold 2 seconds to manually activate or deactivate the radio controlled function.
6. [Alarm]
Press once to switch from clock mode to alarm time display mode.
While in alarm display mode, press once to toggle between arm or disarm the daily alarm.
7. [Clock]
Toggle amongst display for Clock-Sec (HR-MIN-Sec), Clock-day (HR-MIN-Weekday),
Calendar (Date-Month-Year) and repeat…
And 2 buttons inside battery compartment
8. [°C/°F]
Toggle the temperature unit °C <- -> °F
9. [Reset]
To activate system reset to the main unit during abnormal condition which will reset all
settings back to factory values.
GETTING STARTED
This Weather Station was designed for easy set up. For best operation, the following steps
are required to be done in the proper sequence.
1. INSERT BATTERIES FOR MAIN UNIT BEFORE DOING SO FOR THE SENSOR UNITS.
2. RECEIVING UNIT CANNOT BE PROGRAMMED MANUALLY UNTIL THE WIRELESS REMOTE
SENSOR UNIT REGISTRATION PROCEDURE HAS BEEN COMPLETED.
3. POSITION THE REMOTE UNIT AND MAIN UNIT WITHIN EFFECTIVE TRANSMISSION RANGE,
WHICH, IN USUAL CIRCUMSTANCES, IS 165 FEET. Although the remote unit is weather
resistant, it should be placed away from direct sunlight, rain or snow.
BATTERY INSTALLATION FOR MAIN UNIT
1. Remove the battery door;
2. Insert 4 pieces AA size 1.5V alkaline battery as indicate by the polarity;
3. Close the battery door.
Note: Replace the batteries when the low battery indicator appears on the top-right
corner of the LCD.
BATTERY INSTALLATION FOR REMOTE SENSOR UNIT
1. Lift off the bracket stand of the remote sensor unit by releasing the 2 fixing snaps at the
bottom;
2. Use a small Philips type screwdriver to remove the battery cover screws;
3. Insert 2 pieces of AAA size batteries according to the ‘ + ’ and ‘ – ’ polarity marks
shown in the battery compartment and then close the battery door.
WIRELESS REMOTE SENSOR REGISTRATION PROCEDURE
1. Insert x4 AA batteries first to the main unit. The temperature display shows - - . – while
the wave icon will keep blinking for 2 minutes indicate the main unit is in sensor
searching mode.
2. In a second step, insert the x2 AAA batteries into the sensor unit. The LED on the front
panel will start flashing at a rate of one time per around 2 seconds indicates
channel-1 is in use.
3. While the LED is flashing, press once the [CH] button will change the sensor channel
setting to 2. Keep toggle on [CH] button can change channel setting up to 5. The LED
is blinking at a frequency to indicate the channel setting. i.e. continuous blinks 2 times
indicate channel-2 is selected.
Note: If user does not press any key for 10 seconds, it will exit the channel setting mode
and transmit the RF signal. The main unit will register the temperature reading.
(If the transmitter has the LCD display, the °C/°F button will toggle the temperature unit on
the LCD.)
REMOTE CHANNEL AUTO-SCROLLING
This device is equipped with an auto-scroll function. While the auto-scroll function is set,
the unit will automatically cycle to display the temperature of each remote sensor for 6
seconds.
1. To retrieve manually the specific sensor temperature reading, press [CHANNEL] button
until desired channel number is displayed.
2. To enable auto-scroll function, use [CHANNEL] button to toggle channel 1,2,.,. until
auto scroll icon appears on the left hand side of the second line display.
WWVB Radio-Controlled Clock
The atomic clock can receive the WWVB time signal transmitted by the National Institute
of Standards and Technology (NIST), which is regulated by 3 atomic clocks and deviates
less than 1 second without 3,000 years. The NIST broadcasts the time signal continuously
from Fort Collins, Colorado. This signal can be received anywhere in the continental USA
that the signal can cover a distance of over 2,000 miles from the transmitter. Therefore,
your clock receives the signal within the broadcast range anywhere an AM signal can be
received.
However, there are many environment factors may affect the RCC reception, i.e. nearby
computer monitors or other electronic devices, if it is placed on any metal surface,
surrounded by any tall buildings and so on.
The user should place the atomic clock near a window and position it toward the
transmitter in Fort Collins, Colorado. Then, check the RCC strength indicator in the clock
display to see if there is a wave icon above the reception tower. There are 3 wave icons
that flash to indicate 4 levels of signal status:
If there is no wave above the reception tower, this means that the signal is very weak and
the clock cannot be set by the RCC signal. Rotate the unit or position it at another
window to obtain a better RCC reception location. Note that the RCC signal is the
strongest at night. The user can manually set the clock to local time and lea ve it overnight
to receive the RCC signal.
If nothing else works, take the clock outdoors at night, remove and re-install the batteries
and leave it overnight to force it to search for the radio-controlled time signal. If the clock
works outdoors but not indoors, you probably have a local interference problem inside
your house or building.
Once the time signal is received, the wave icon remains on the LCD. The time and
calendar is automatically updated.
Note: Within 10 minutes of time-signal reception, all manual settings are suspended. If
setting is desired, press the [▲] button once to deactivate the reception. You can also
press and hold the same button for 3 seconds to manually activate the reception when in
Normal mode.
SET THE CLOCK, CALENDAR & LANGUAGE
1. Press & hold [CLOCK] button for 2 seconds to enter clock setting mode. Flashing 12
hours will appear.
2. Press [ + ] or [ - ] button to switch between 24 hours and 12 hours format, and then
press [CLOCK] button to confirm.
3. The icon “P” that represents the Pacific Time zone in North America starts to flash. To
select desired time zone: Pacific (P), Mountain (M), Central (C) or Eastern (E), press [ + ]
or [ - ] button. Press [CLOCK] button to confirm.
4. The hour digits will flash. Use the [ + ] button to increase by one hour or [ - ] button to
decrease by one hour to your desired hours. Holding down either button will change
the increment rapidly. Press [CLOCK] button to confirm.
5. The minute digits will flash. Use the [ + ] button or [ - ] button to set your desired minutes.
Holding down either button will change the increment rapidly. Press [CLOCK] button
to confirm.
Note: Every change of minute digit will automatically reset the seconds to zero.
6. The “DS” digits indicate DST setting. To select daylight saving time to ON or
OFF, press [ + ] or [ - ]. Press [CLOCK] button to confirm.
7. The year digit will flash and Yr icon appears. Press [ + ] or [ - ] button to set your desired
year. Press [CLOCK] button to confirm.
Note: Year range is from 2000 to 2099.
8. M and D icons will flash. Press [ + ] or [ - ] button to select M D(Month Date) or D M
(Date Month) format. Press [CLOCK] button to confirm.
9. Month digits will flash. Press [ + ] or [ - ] button to set your desired month. Press [CLOCK]
button to confirm. Do the same to set Date.
Note: The month phase and the weekday will be automatically calculated and
displayed for the date set above.
10. E digit will flash. Press [ + ] or [ - ] button to switch 5 languages display of weekday
(English/German/French/Spanish/Italian. See table 1). Press [CLOCK] button to
confirm and exit setting mode
Note: If no key press during setting mode for 10 seconds, it will automatically keep the
setting and exit to normal display.
To set daily alarm
1. In clock time display mode, press [Alarm] button once to switch to display alarm time
for 10 seconds.
2. Press [Alarm] button again in alarm display mode to arm or disarm the daily alarm.
3. Press and hold [Alarm] button for 2 seconds to enter alarm setting mode.
4. The hour digits will flash, use [ + ] button to increase by one hour or [ - ] button to
decrease by one hour to your desired hours. Holding down the button will change the
increment rapidly. Press [Alarm] button to confirm.
5. The minute digits will flash. Use [ + ] button to increase by one minute or [ - ] button to
decrease by one minute to your desired minutes. Holding down the button will
change the increment rapidly. Press [Alarm] button to confirm and finish the setting.
MOON PHASE
Our weather station is equipped with 8 moon phases display (i.e. from new moon to
waning crescent) on the screen.
• The animated rolling moon phase will pause 5 seconds in the place of the current
month phase calculated by the current calendar date.
• The user also can press [ + ] button or [ - ] button go through the calendar to check the
moon phase for a specific date other than the current date.
WEATHER FORECAST
Our weather station is capable of detecting local barometric pressure changes, and
based on the data collected, predicts the weather forecast for the next 12 to 24 hours.
Note:
1. The accuracy of a general pressure-based weather forecast is about 70 to 75%, and
therefore, we cannot be held responsible for any inconveniences so caused by an
inaccurate one.
2. The weather forecast is meant for the next 12 to 24 hours. It may not necessarily reflect
the current situation.
3. The ‘Sunny’ forecast covering night hours indicates clear weather.
SPECIFICATIONS
Main Unit
Displayed IN temperature range
Proposed operating range
Temperature resolution
: -10°C to +60.0°C (14°F to 140.0°F)
: 0°C to +50.0°C (32.0°F - 122.0°F)
: 0.1°C (0.2°F)
Remote Unit
Displayed range
: -20.0°C to +60.0°C (-4.0°F to 140.0°F)
Proposed operating range
: -10.0°C to +60.0°C (14.0°F to 140.0°F)
Temperature resolution
: 0.1°C (0.2°F)
Displayed Relative Humidity range : 25%RH to 95%RH
RF Transmission Frequency
: 433 MHz
RF Transmission Range
: 30 meters at open area
Statement of FCC compliance
Modifications not authorized by the manufacturer may void users authority to
operate this device.
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
--Consult the dealer or an experienced radio/TV technician for help.
FCC Label Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Title                           : Microsoft Word - WSU601&THX201_UserManual.doc
Author                          : cee3
Creator                         : pdfFactory http://www.pdffactory.com
Producer                        : pdfFactory v1.57 (Windows XP Chinese)
Create Date                     : 2008:07:16 15:43:56
Page Count                      : 8
EXIF Metadata provided by EXIF.tools
FCC ID Filing: N9ZTHX201

Navigation menu