Falcon T Series Installation Instructions Electrical 110164
User Manual: Falcon T-Series Installation Instructions - Electrical Installation Instructions
Open the PDF directly: View PDF .
Page Count: 1

© Allegion 2015
Printed in U.S.A.
031476 Rev. 09/15-e
*031476*
031476
Models RU851, RU881, T851, T881
RU-Series and T-Series
Electried Locks
Wiring Instructions
Field Splice
AC/DC Converter
Electric Hinge Transformer
BLACK
BLACK
RED
BLUE
GREEN
BLACK
WHITE
RED
BLUEBLACK
BLUE RED
24VAC
115 VAC
60Hz
Field Splice
Electric Hinge
Power Supply
RED
BLUE + RED
WHITE + BLACK RED
12VDC
Typical Wiring Diagram DC Lock
Typical Wiring Diagram DC Lock With AC/DC Converter
RU851, T851 Storeroom Fail Safe:
Deadlocking latch bolt operated by lever from
either side, except when outer lever is electrically
locked. When outer lever is locked (inoperable),
latch bolt retracted by key in cylinder outside.
Inside lever is always free.
RU881, T881 Storeroom Fail Secure:
Deadlocking latch bolt operated by lever inside
at all times. Outside lever is inoperable until
electrically unlocked, then latch bolt is operable
from either side. When outside lever is inoper-
able, latch bolt retracted by key in cylinder
outside.
12 VDC Configuration Shown
24 VDC Configuration Shown
Electrical Specifications:
Fail Safe/Fail Secure
.65 AMP @ 12 VDC
.32 AMP @ 24 VDC
Wiring Configurations for 12 VDC or 24 VDC input
12 VDC
Wires Connected In Parallel
18.5 OHMS Total
WHITEBLUE
RED BLACK
24 VDC
Wires Connected In Series
74 OHMS Total
RED BLACK BLUE WHITE
T851, T881RU851, RU881