Fanvil Technology I30 IP DoorPhone User Manual

Fanvil Technology Co., LTD. IP DoorPhone

Contents

User manual i20S

[键入文字]             i20S IP DoorPhone User Manual V3.0
[键入文字]           Document VER Firmware VER Explanation Time V1.0 2.0.0.2485 Initial issue 20160830 V2.0 2.1.1.2898 Add FDMS, video linkage function. Changed default in passive mode to the electric-lock. 20170726 V3.0 2.1.1.2898 Change company address and add IP scan tool download address in QIG 20171027
[键入文字]          Safety Notices  1. Please use the specified power adapter. If you need to use the power adapter provided by other manufacturers under special circumstances, please make sure that the voltage and current provided is in accordance with the requirements of this product, meanwhile, please use the safety certificated products, otherwise may cause fire or get an electric shock. 2. When using this product, please do not damage the power cord either by forcefully twist it, stretch pull, banding or put it under heavy pressure or between items, otherwise it may cause damage to the power cord, lead to fire or get an electric shock. 3. Before using, please confirm that the temperature and environment is humidity suitable for the product to work. (Move the product from air conditioning room to natural temperature, which may cause this product surface or internal components produce condense water vapor, please open power use it after waiting for this product is natural drying). 4. Please do not let non-technical staff to remove or repair. Improper repair may cause electric shock, fire, malfunction, etc. It will lead to injury accident or cause damage to your product.   5. Do not use fingers, pins, wire, other metal objects or foreign body into the vents and gaps. It may cause current through the metal or foreign body, which may even cause electric shock or injury accident. If any foreign body or objection falls into the product please stop using. 6. Please do not discard the packing bags or store in places where children could reach, if children trap his head with it, may cause nose and mouth blocked, and even lead to suffocation. 7. Please use this product with normal usage and operating, in bad posture for a long time to use this product may affect your health. 8. Please read the above safety notices before installing or using this phone. They are crucial for the safe and reliable operation of the device.
[键入文字]          FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential  installation.  This  equipment  generates  uses  and  can  radiate  radio  frequency  energy  and,  if  not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:   —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver.   —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   —Consult the dealer or an experienced radio/TV technician for help.     FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  Caution!   Any changes or modifications not expressly approved by the party responsible for compliance could  void the user's authority to operate the equipment.  FCC Radiation Exposure Statement This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules. This equipment must not be co-located or operating in conjunction with  any  other  antenna  or  transmitter.  End-users  and  installers  must  be  provide  with  antenna  installation instructions and consider removing the no-collocation statement.
[键入文字]          Directory I. Product introduction ............................................................................................................................ 6 1. Appearance of the product .............................................................................................................. 6 2. Description ...................................................................................................................................... 6 II. Start Using .......................................................................................................................................... 7 1. Confirm the connection ................................................................................................................... 7 1) Power, Electric Lock, Indoor switch port ........................................................................................ 7 2) Driving mode of electric-lock(Default in passive mode) ................................................................. 7 3) Wiring instructions ....................................................................................................................... 8 2. Quick Setting ................................................................................................................................... 9 III. Basic operation ................................................................................................................................ 10 1. Answer a call ................................................................................................................................. 10 2. Call ................................................................................................................................................ 10 3. End call .......................................................................................................................................... 10 4. Open the door operation ............................................................................................................... 10 IV. Page settings ................................................................................................................................... 11 1. Browser configuration ................................................................................................................... 11 2. Password Configuration ................................................................................................................. 11 3. Configuration via WEB ................................................................................................................... 12 (1) System ...................................................................................................................................... 12 a) Information ............................................................................................................................. 12 b) Account .................................................................................................................................. 13 c) Configurations ......................................................................................................................... 14 d) Upgrade .................................................................................................................................. 14 e) Auto Provision ........................................................................................................................ 15 f) FDMS ...................................................................................................................................... 17 g) Tools ....................................................................................................................................... 17 (2) Network .................................................................................................................................... 19 a) Basic ....................................................................................................................................... 19 b) VPN ........................................................................................................................................ 21 (3) Line ........................................................................................................................................... 22 a) SIP .......................................................................................................................................... 22 b) Basic Settings .......................................................................................................................... 27 c) Dial peer ................................................................................................................................. 28
[键入文字]          (4) EGS Setting ............................................................................................................................... 30 a) Features.................................................................................................................................. 30 b) Audio ...................................................................................................................................... 33 c) Video ...................................................................................................................................... 34 d) MCAST .................................................................................................................................... 35 e) Action URL .............................................................................................................................. 38 f) Time/Date ............................................................................................................................... 38 (5) EGS Access ................................................................................................................................ 40 (6) EGS Logs ................................................................................................................................... 42 (7) Function Key ............................................................................................................................. 43 V. Appendix .......................................................................................................................................... 45 1. Technical parameters ..................................................................................................................... 45 2. Basic functions .............................................................................................................................. 46 3. Schematic diagram ........................................................................................................................ 46 VI. Other instructions ............................................................................................................................ 47 1. Open door modes .......................................................................................................................... 47 2. Management of card ..................................................................................................................... 47
[键入文字]          6 / 51   I. Product introduction i20S voice access is a full digital network door phone, with its core part adopts mature VoIP solution (Broadcom chip), stable and reliable performance, hands-free adopting digital full-duplex mode, voice loud and clear, generous appearance, solid durable, easy for installation, comfortable keypad and low power consumption. i20S voice access supports entrance guard control, voice intercom, ID card and keypad remote to open the door. 1. Appearance of the product  2. Description Buttons and icons Description Function  Numeric keyboard Input password to open the door or to call.  programmable keys Can be set to a variety of functions, in order to meet the needs of different occasions  induction zone RFID induction area  Lock Status Door unlocking: On Door locking: Off  Call/Ring status Standby: Off Calls: On Ringing: Blink with 1s  Network/SIP Registration Network error: Blink with 1s Network running: Off Registration failed: Blink with 3s Registration succeeded: On
[键入文字]          7 / 51   II. Start Using Before you start to use the equipment, please make the following installation.  1. Confirm the connection Confirm whether the equipment of the power cord, network cable, electric lock control line connection and the boot-up is normal. (Check the network state of light) 1) Power, Electric Lock, Indoor switch port   Voice access the power supply ways: 12v/DC or POE.    CN7  1 2 3 4 5 6 7 +12V VSS NC COM NO S_IN S_OUT 12V 1A/DC Electric-lock switch Indoor switch  2) Driving mode of electric-lock(Default in passive mode)      【Note】When the device is in active mode, it can drive 12V/700mA switch output maximum, to which a standard electric-lock or another compatible electrical appliance can be connected.    When using the active mode, it is 12V DC in output.  When using the passive mode, output is short control (normally open mode or normally close mode).        Jumper in passive mode  Jumper in active mode
[键入文字]          8 / 51   3) Wiring instructions  NO: Normally Open Contact.  COM: Common Contact.  NC: Normally Close Contact. Driving Mode Electric lock Jumper port Connections Active Passive No electricity when open When the power to open √      √   √    √ √     √  √    √ √
[键入文字]          9 / 51   2. Quick Setting The product provides a complete function and parameter setting. Users may need to have the network and SIP protocol knowledge to understand the meaning represented by all parameters. In order to let equipment users enjoy the high quality of voice service and low cost advantage brought by the device immediately, here we list some basic but compulsory setting options in this section to let users know how to operate without understanding such complex SIP protocols. In prior to this step, please make sure your broadband Internet online can be normal operated, and complete the connection of the network hardware. The product factory default network mode is DHCP. Thus, only connect equipment with DHCP network environment that network can be automatically connected.  Press and hold “#” key for 3 seconds and the door phone will report the IP address by voice, or use the "iDoorPhoneNetworkScanner.exe" software to find the IP address of the device. (Download address http://download.fanvil.com/tool/iDoorPhoneNetworkScanner.exe )  Note: when power on, 30s waiting is needed for device running.  Log on to the WEB device configuration.  In a Line page configuration service account, user name, parameters that are required for server address register.  You can set DSS key in the Function key page.  You can set Door Phone parameters in the Webpage (EGS Setting-> Features).
[键入文字]          10 / 51   III. Basic operation 1. Answer a call When a call comes in, the device will answer automatically. If you cancel auto answer feature and set auto answer time, you will hear the bell ring at the set time and the device will auto answer after a timeout. 2. Call Configure shortcut key as hot key and setup a number, then press shortcut key can call the configured number. 3. End call Enable Release key hang up to end call. 4. Open the door operation Through the following seven ways to open the door: 1) Input password on the keyboard to open the door. 2) Access to call the owner and the owner enter the remote password to open the door. 3) Owner/other equipment call the access control and enter the access code to open the door. (access code should be included in the list of access configuration, and enable for remote calls to open the door) 4) Swipe the RFID cards to open the door. 5) By means of indoor switch to open the door. 6) Private access code to open the door. Enable for local authentication, and set private access code. Input the access code directly under standby mode to open the door. In this way, the door log will record corresponding card number and user name. 7) Active URL control command to open the door. URL is “http://user:pwd@host/cgi-bin/ConfigManApp.com?key=F_LOCK&code=openCode” a. User and pwd is Web the user name and password. b. “openCode” is the remote control code to open the door. Example: “http://admin:admin@172.18.3.25/cgi-bin/ConfigManApp.com?key=*”  If access code is input correctly, the device will play sirens sound to prompt access control and the remote user, while input error by low-frequency short chirp. Password input successfully followed by high-frequency sirens sound, while input error is followed by
[键入文字]          11 / 51   high-frequency short chirp. When door has been opened, the device will play sirens sound to prompt.  IV. Page settings 1. Browser configuration When the device and your computer are successfully connected to the network, enter the IP address of the device on the browser as http://xxx.xxx.xxx.xxx/ and you can see the login interface of the web page management.   Enter the user name and password and click the [logon] button to enter the settings screen.   2. Password Configuration There are two levels of access: root level and general level. A user with root level access can browse and set all configuration parameters, while a user with general level can set all configuration parameters except server parameters for SIP.  Default user with general level: The default is not set, are free to add.  Default user with root level:  User name: admin  Password: admin
[键入文字]          12 / 51   3. Configuration via WEB (1) System a) Information   Information Field Name Explanation System Information Display  equipment  model,  hardware  version,  software  version,  uptime,  Last uptime and MEMinfo. Network Shows the configuration information for WAN port, including connection mode of WAN port (Static, DHCP, PPPoE), MAC address, IP address of WAN port. SIP Accounts Shows the phone numbers and registration status for the 2 SIP LINES.
[键入文字]          13 / 51   b) Account Through this page, user can add or remove users depends on their needs and can modify existing user permission.   Account Field Name Explanation Change Web Authentication Password You Can modify the login password to the account Add New User You can add new user User Accounts Show the existing user information
[键入文字]          14 / 51   c) Configurations   Configurations Field Name Explanation Export Configurations Save  the equipment configuration to  a  txt  or  xml  file. Please note to Right click on the choice and then choose “Save Link As.” Import Configurations Browse to the config file, and press Update to load it to the equipment.   Reset to factory defaults This will restore factory default and remove all configuration information.  d) Upgrade   Upgrade Field Name Explanation Software upgrade Browse to the firmware, and press Update to load it to the equipment.
[键入文字]          15 / 51   e) Auto Provision  Auto Provision Field Name Explanation Common Settings Current Configuration Version Show the current config file’s version. If the version of configuration downloaded is higher than this, the configuration will be upgraded. If the endpoints confirm the configuration by the Digest method, the configuration will not be upgraded unless it differs from the current configuration General Configuration Version Show the common config file’s version. If the configuration downloaded and this configuration is the same, the auto provision will stop. If the endpoints confirm the configuration by the Digest method, the configuration will not be upgraded unless it differs from the current configuration. CPE Serial Number Serial number of the equipment Authentication Name Username for configuration server. Used for FTP/HTTP/HTTPS. If this is blank the phone will use anonymous Authentication Password Password for configuration server. Used for FTP/HTTP/HTTPS. Configuration File Encryption Key Encryption key for the configuration file General Configuration File Encryption Key Encryption key for common configuration file Save Auto Provision Information Save the auto provision username and password in the phone until the server url changes
[键入文字]          16 / 51   DHCP Option Option Value The equipment supports configuration from Option 43, Option 66, or a Custom DHCP option. It may also be disabled. Custom Option Value Custom option number. Must be from 128 to 254. SIP Plug and Play (PnP) Enable SIP PnP If this is enabled, the equipment will send SIP SUBSCRIBE messages to a multicast address when it boots up. Any SIP server understanding that message will reply with a SIP NOTIFY message containing the Auto Provisioning Server URL where the phones can request their configuration. Server Address PnP Server Address Server Port PnP Server Port Transportation Protocol PnP Transfer protocol – UDP or TCP Update Interval Interval time for querying PnP server. Default is 1 hour. Static Provisioning Server Server Address Set FTP/TFTP/HTTP server IP address for auto update. The address can be an IP address or Domain name with subdirectory. Configuration File Name Specify configuration file name. The equipment will use its MAC ID as the config file name if this is blank. Protocol Type Specify the Protocol type FTP, TFTP or HTTP. Update Interval Specify the update interval time. Default is 1 hour. Update Mode 1. Disable – no update 2. Update after reboot – update only after reboot. 3. Update at time interval – update at periodic update interval TR069 Enable TR069 Enable/Disable TR069 configuration ACS Server Type Select Common or CTC ACS Server Type. ACS Server URL ACS Server URL. ACS User User name for ACS. ACS Password ACS Password. TR069 Auto Login Enable/Disable TR069 Auto Login. INFORM Sending Period Time between transmissions of “Inform” Unit is seconds.
[键入文字]          17 / 51   f) FDMS  FDMS Settings Enable FDMS Enable/Disable FDMS configuration FDMS Interval The time to send sip Subscribe information to the FDMS server on a regular basis. Unit seconds Doorphone Info Settings Community Name The name of the community where the device is installed Building Number The name of the building where the equipment is installed Room Number The name of the room where the equipment is installed   g) Tools
[键入文字]          18 / 51   Syslog is a protocol used to record log messages using a client/server mechanism. The Syslog server receives the messages from clients, and classifies them based on priority and type. Then these messages will be written into a log by rules which the administrator has configured.   There are 8 levels of debug information. Level 0: emergency; System is unusable. This is the highest debug info level.   Level 1: alert; Action must be taken immediately. Level 2: critical; System is probably working incorrectly. Level 3: error; System may not work correctly. Level 4: warning; System may work correctly but needs attention. Level 5: notice; It is the normal but significant condition. Level 6: Informational; It is the normal daily messages. Level 7: debug; Debug messages normally used by system designer. This level can only be displayed via telnet.  Tools Field Name Explanation Syslog Enable Syslog Enable or disable system log. Server Address System log server IP address. Server Port System log server port. APP Log Level Set the level of APP log. SIP Log Level Set the level of SIP log. Network Packets Capture Capture a packet stream from the equipment. This is normally used to troubleshoot problems. Reboot Phone Some configuration modifications require a reboot to become effective. Clicking the Reboot button will lead to reboot immediately. Note: Be sure to save the configuration before rebooting.
[键入文字]          19 / 51   (2) Network a) Basic  Field Name Explanation Network Status IP The current IP address of the equipment Subnet mask The current Subnet Mask Default gateway The current Gateway IP address MAC The MAC address of the equipment MAC Timestamp Get the MAC address of time. Settings Select the appropriate network mode. The equipment supports three network modes: Static IP Network parameters must be entered manually and will not change. All parameters are provided by the ISP. DHCP Network parameters are provided automatically by a DHCP server. PPPoE Account and Password must be input manually. These are provided by your ISP. If Static IP is chosen, the screen below will appear. Enter values provided by the ISP. DNS Server Configured by Select the Configured mode of the DNS Server. Primary DNS Server Enter the server address of the Primary DNS.
[键入文字]          20 / 51   Secondary DNS Server Enter the server address of the Secondary DNS. After entering the new settings, click the APPLY button. The equipment will save the new settings and apply them. If a new IP address was entered for the equipment, it must be used to login to the phone after clicking the APPLY button. Service Port Settings Web Server Type Specify Web Server Type – HTTP or HTTPS HTTP Port Port for web browser access. Default value is 80. To enhance security, change this from the default. Setting this port to 0 will disable HTTP access. Example: The IP address is 192.168.1.70 and the port value is 8090, the accessing address is http://192.168.1.70:8090. HTTPS Port Port for HTTPS access. Before using https, an https authentication certification must be downloaded into the equipment. Default value is 443. To enhance security, change this from the default. Note: 1) Any changes made on this page require a reboot to become active. 2) It is suggested that changes to HTTP Port be values greater than 1024.Values less than 1024 are reserved. 3) If the HTTP port is set to 0, HTTP service will be disabled.
[键入文字]          21 / 51   b) VPN The  device supports remote connection via  VPN. It supports both Layer 2  Tunneling Protocol (L2TP) and OpenVPN protocol. This allows users at remote locations on the public network to make secure connections to local networks.
[键入文字]          22 / 51   Field Name   Explanation   VPN IP Address Shows the current VPN IP address. VPN Mode Enable VPN Enable/Disable VPN. L2TP Select Layer 2 Tunneling Protocol OpenVPN Select OpenVPN Protocol. (Only one protocol may be activated. After the selection is made, the configuration should be saved and the phone be rebooted.) Layer 2 Tunneling Protocol (L2TP) L2TP Server Address Set VPN L2TP Server IP address. Authentication Name Set User Name access to VPN L2TP Server. Authentication Password Set Password access to VPN L2TP Server. Open VPN Files Upload or delete Open VPN Certification Files  (3) Line a) SIP Configure a SIP server on this page.
[键入文字]          23 / 51     SIP Field Name Explanation Basic Settings (Choose the SIP line to configured) Line Status Display the current line status at page loading. To get the up to date line status, user has to refresh the page manually.
[键入文字]          24 / 51   Username Enter the username of the service account. Display name Enter the display name to be sent in a call request. Authentication Name Enter the authentication name of the service account Authentication Password Enter the authentication password of the service account Activate Whether the service of the line should be activated SIP Proxy Server Address Enter the IP or FQDN address of the SIP proxy server SIP Proxy Server Port Enter the SIP proxy server port, default is 5060 Outbound proxy address Enter the IP or FQDN address of outbound proxy server provided by the service provider Outbound proxy port Enter the outbound proxy port, default is 5060 Realm Enter the SIP domain if requested by the service provider Codecs Settings Set the priority and availability of the codecs by adding or remove them from the list. Advanced Settings Call Forward Unconditional Enable unconditional call forward, all incoming calls will be forwarded to the number specified in the next field Call Forward Number for Unconditional Set the number of unconditional call forward Call Forward on Busy Enable call forward on busy, when the phone is busy, any incoming call will be forwarded to the number specified in the next field Call Forward Number for Busy Set the number of call forward on busy Call Forward on No Answer Enable call forward on no answer, when an incoming call is not answered within the configured delay time, the call will be forwarded to the number specified in the next field Call Forward Number for No Answer Set the number of call forward on no answer Call Forward Delay for No Answer Set the delay time of not answered call before being forwarded Hotline Delay Set the delay for hotline before the system automatically dialed it Enable Auto Answering Enable auto-answering, the incoming calls will be answered automatically after the delay time Auto Answering Delay Set  the  delay  for  incoming  call  before  the  system  automatically answered it Subscribe For Voice Message Enable the device to subscribe a voice message waiting notification, if enabled, the device will receive notification from the server if there is voice message waiting on the server Voice Message Number Set the number for retrieving voice message
[键入文字]          25 / 51   Voice Message Subscribe Period Set the interval of voice message notification subscription Enable Hotline Enable hotline configuration, the device will dial to the specific number immediately at audio channel opened by off-hook handset or turn on hands-free speaker or headphone Hotline Number Set the hotline dialing number Enable DND Enable Do-not-disturb, any incoming call to this line will be rejected automatically Blocking Anonymous Call Reject any incoming call without presenting caller ID Use 182 Response for Call waiting Set the device to use 182 response code at call waiting response Anonymous Call Standard Set the standard to be used for anonymous Dial Without Registered Set call out by proxy without registration Click To Talk Set Click To Talk User Agent Set the user agent, the default is Model with Software Version. Use Quote in Display Name Whether to add quote in display name Ring Type Set the ring tone type for the line Conference Type Set the type of call conference, Local=set up call conference by the device itself, maximum supports two remote parties, Server=set up call conference by dialing to a conference room on the server Server Conference Number Set the conference room number when conference type is set to be Server Transfer Timeout Set the timeout of call transfer process Enable Long Contact Allow more parameters in contact field per RFC 3840 Enable Missed Call Log If enabled, the phone will save missed calls into the call history record. Response Single Codec If  setting  enabled,  the  device  will  use  single  codec  in  response  to  an incoming call request Use Feature Code When this setting is enabled, the features in this section will not be handled by the device itself but by the server instead. In order to control the enabling of the features, the device will send feature code to the server by dialing the number specified in each feature code field. Specific Server Type Set the line to collaborate with specific server type Registration Expiration Set the SIP expiration interval Use VPN Set the line to use VPN restrict route Use STUN Set the line to use STUN for NAT traversal Convert URI Convert not digit and alphabet characters to %hh hex code DTMF Type Set the DTMF type to be used for the line
[键入文字]          26 / 51   DTMF SIP INFO Mode Set the SIP INFO mode to send ‘*’ and ‘#’ or ‘10’ and ‘11’ Transportation Protocol Set the line to use TCP or UDP for SIP transmission SIP Version Set the SIP version Caller ID Header Set the Caller ID Header Enable Strict Proxy Enables  the  use  of  strict  routing.  When  the  phone  receives  packets from the server, it will use the source IP address, not the address in via field. Enable user=phone Sets user=phone in SIP messages. Enable SCA Enable/Disable SCA (Shared Call Appearance ) Enable BLF List Enable/Disable BLF List Enable DNS SRV Set the line to use DNS SRV which will resolve the FQDN in proxy server into a service list Keep Alive Type Set  the  line  to  use  dummy  UDP  or  SIP  OPTION  packet  to  keep  NAT pinhole opened Keep Alive Interval Set the keep alive packet transmitting interval Enable Session Timer Set the line to enable call ending by session timer refreshment. The call session  will  be  ended  if  there  is  not  new session  timer  event update received after the timeout period Session Timeout Set the session timer timeout period Enable Rport Set the line to add rport in SIP headers Enable PRACK Set the line to support PRACK SIP message Keep Authentication Keep the authentication parameters from previous authentication Auto TCP Using TCP protocol to guarantee usability of transport for SIP messages above 1500 bytes Enable Feature Sync Feature Sycn with server Enable GRUU Support Globally Routable User-Agent URI (GRUU) BLF Server The  registered  server  will  receive  the  subscription  package  from ordinary application of BLF phone. Please enter the BLF server, if the sever does not support subscription package,  the  registered  server  and  subscription  server  will  be separated. BLF List Number BLF List allows one BLF key to monitor the status of a group. Multiple BLF lists are supported. SIP Encryption Enable SIP encryption such that SIP transmission will be encrypted SIP Encryption Key Set the pass phrase for SIP encryption RTP Encryption Enable RTP encryption such that RTP transmission will be encrypted RTP Encryption Key Set the pass phrase for RTP encryption
[键入文字]          27 / 51   b) Basic Settings STUN – Simple Traversal of UDP through NAT –A STUN server allows a phone in a private network to know  its  public  IP  and  port  as  well  as  the  type  of  NAT  being  used.  The  equipment  can  then  use  this information  to  register  itself  to  a  SIP  server  so  that  it  can  make  and  receive  calls  while  in  a  private network.   Basic Settings Field Name   Explanation   SIP Settings Local SIP Port Set the local SIP port used to send/receive SIP messages. Registration Failure Retry Interval Set the retry interval of SIP REGISTRATION when registration failed.
[键入文字]          28 / 51   Enable Strict UA Match Enable or disable Strict UA Match STUN Settings Server Address STUN Server IP address Server Port STUN Server Port – Default is 3478. Binding Period STUN blinding period – STUN packets are sent at this interval to keep the NAT mapping active. SIP Waiting Time Waiting time for SIP. This will vary depending on the network. TLS Certification File Upload or delete the TLS certification file used for encrypted SIP transmission. Note: the SIP STUN is used to achieve the SIP penetration of NAT, is the realization of a service, when the equipment configuration of the STUN server IP and port (usually the default is 3478), and select the Use Stun SIP server, the use of NAT equipment to achieve penetration.  c) Dial peer  Import Dial peer Table Field Name   Explanation   Select File Select an existing dialing rule file. The file type must be a .CSV Add Dial Peer Number In order to add an outgoing call number, the outgoing call number can be divided into two types: one is the exact match, and after the exact match, if the number is exactly the same as the user dialing the called number, the device will use the IP address of this number mapping or (This is the area code prefix function of the PSTN).  If  the  number  matches  the  N-bit  (prefix  number  length)  of  the  called number, the device uses the IP address or configuration mapped to this number.
[键入文字]          29 / 51   Make  a  call.  Configuration  prefix  matching  needs  to  be  followed  by  a  prefix number to match the exact match number; the longest support of 30 bits; also supports the use of x format and range of numbers. Destination Configure the destination address and, if configured as a point-to-point call, write the peer IP address directly. Can also be set to domain name, by the device DNS server to resolve the specific IP address. If it is not configured, the IP address is 0.0.0.0. This is an optional configuration item Port Configure the signaling port of the other party. This is an optional configuration item. The default is 5060v Alias Configure aliases, this is an optional item: the replacement number used when the prefix is prefixed, and no alias when configured Note: aliases are divided into four types and must be combined with the replacement length: 1) add: xxx, add xxx before the number. This can help users save dialing length; 2) all: xxx, all replaced by xxx; can achieve speed dial, such as user configuration dial-up 1, then by configuring all: number to change the actual call out the number; 3) del, delete the number before the n bit, n by the replacement length set; 4) rep: xxx, the number n before the number is replaced by xxx, n is set by the replacement length. For example, if the user wants to dial the PSTN (010-62281493) through the floor service provided by the VoIP operator, and the actual call should be 010-62281493, then we can configure the called number 9T, then rep: 010, and then delete the length Set to 1. Then all users call the 9 at the beginning of the phone will be replaced with 010 + number sent. To facilitate the user to call the habit of thinking mode; Call Mode Configuration selection of different signaling protocols, SIP / IAX2; Suffix Configure the suffix, this is optional configuration items: that is, after the dial-up number to add this suffix, no configuration shows no suffix; Deleted Length Configure  the  replacement  /  delete  length,  the  number  entered  by  the  user  is replaced / deleted by this length; this is an optional configuration item;
[键入文字]          30 / 51   (4) EGS Setting a) Features    Features Field Name   Explanation   Common Settings Switch Mode Monostable: there is only one fixed action status for door unlocking. Bistable: there are two actions and statuses, door unlocking and door locking. Each action might be triggered and changed to the other status. After changed, the status would be kept. Initial Value is Monostable Switch-On Duration Door unlocking time for Monostable mode only. If the time is up, the door would be locked automatically. Initial Value is 5 seconds.
[键入文字]          31 / 51   Enable Card Reader Enable or disable card reader for RFID cards. Card Reader Working Mode Set ID card stats: Normal: This is the work mode, after the slot card can to open the door.   Card Issuing: This is the issuing mode, after the slot card can to add ID cards. Card Revoking: This is the revoking mode, after the slot card can to delete ID cards. Limit Talk Duration If enabled, calls would be forced ended after talking time is up. Talk Duration The call will be ended automatically when time up. Initial Value is 120 seconds Remote Password Remote door unlocking password. Initial Value is “*”. Local password Local door unlocking password via keypad, the default password length is 4. Initial Value is “6789”. APP Door Open Enable or disable the APP Door Open APP password APP door unlocking password. Initial Value is  “*”. Enable Indoor Open Enable or disable to use indoor switch to unlock the door. Enable Access Table Enable Access Table: enter <Access Code> for opening door during calls. Disable Access Table: enter <Remote Password> for opening door during calls. Default Enable. Description Device description displayed on IP scanning tool software. Initial Value is “i20S IP Door Phone”. Enable Open Log Server Enable or disable to connect with log server Address of Open Log Server Log server address(IP or domain name) Port of Open Log Server Log server port (0-65535) , Initial Value is 514. Door Unlock Indication Indication tone for door unlocked. There are 3 type of tone: silent/short beeps/long beeps. Remote Code Check Length The remote access code length would be restricted with it. If the input access code length is matched with it, system would check it immediately. Initial Value is 4. Basic Settings Enable DND DND might be disabled phone for all SIP lines, or line for SIP individually. But the outgoing calls will not be affected Ban Outgoing If enabled, no outgoing calls can be made. Enable Intercom Mute If enabled, mutes incoming calls during an intercom call.
[键入文字]          32 / 51   Enable Intercom Ringing If enabled, plays intercom ring tone to alert to an intercom call. Enable Auto Dial Out Enable Auto Dial Out Auto Dial Out Time Set Auto Dial Out Time Enable Auto Answer Enable Auto Answer function Auto Answer Timeout Set Auto Answer Timeout No Answer Auto Hangup Enable automatically hang up when no answer Auto Hangup Timeout Configuration in a set time, automatically hang up when no answer Dial Fixed Length to Send Enable or disable dial fixed length to send. Send length The number will be sent to the server after the specified numbers of digits are dialed. Dial Number Voice Play Configuration Open / Close Dial Number Voice Play Voice Play Language Set language of the voice prompt Enable Delay Start Enable or disable the start delay Delay Start Time Set start delay time Voice Read IP Enable or disable voice broadcast IP address Press "*" to Send Enable or disable the Press "*" to Send, Initial Value is enable Block Out Settings Add or delete blocked numbers – enter the prefix of numbers which should not be dialed by the phone. For example, if 001 is entered, the phone would not dial any number beginning with 001. X and x are wildcards which match single digit. For example, if 4xxx or 4XXX is entered, the phone would not dial any 4 digits numbers beginning with 4. It would dial numbers beginning with 4 which are longer or shorter than 4 digits.
[键入文字]          33 / 51   b) Audio This page configures audio parameters such as voice codec, speak volume, mic volume and ringer volume.   Audio Setting Field Name   Explanation   First Codec The first codec choice: G.711A/U, G.722, G.723.1, G.726-32, G.729AB Second Codec The second codec choice: G.711A/U, G.722, G.723.1, G.726-32, G.729AB, None Third Codec The third codec choice: G.711A/U, G.722, G.723.1, G.726-32, G.729AB, None Fourth Codec The forth codec choice: G.711A/U, G.722, G.723.1, G.726-32, G.729AB, None DTMF Payload Type The RTP Payload type that indicates DTMF. Default is 101 Default Ring Type Ring Sound – There are 9 standard types and 3 User types. G.729AB Payload Length G.729AB Payload Length – Adjusts from 10 – 60 mSec. Tone Standard Configure tone standard area. G.722 Timestamps Choices are 160/20ms or 320/20ms. G.723.1 Bit Rate Choices are 5.3kb/s or 6.3kb/s. Speakerphone Volume Set the speaker calls the volume level. MIC Input Volume Set the MIC calls the volume level.
[键入文字]          34 / 51   Broadcast Output Volume Set the broadcast the output volume level. Signal Tone Volume Set the audio signal the output volume level. Enable VAD Enable or disable Voice Activity Detection (VAD). If VAD is enabled, G729 Payload length cannot be set greater than 20 mSec.  c) Video   Connection mode Select external, click [Apply], restart the device IP Camera Settings(External Mode) Field Name Explanation User name External camera login required account Password External camera login password required Camera type Select the camera manufacturers IP address IP address of the camera, please use the camera matching scan tool to obtain the IP address Port Camera port number RTSP information Click [Apply], the connection automatically shows the camera does not show the reverse Preview Copy and paste the main stream or sub-stream Url into the VLC player, or click [Preview] to display the current camera video
[键入文字]          35 / 51   d) MCAST  It is easy and convenient to use multicast function to send notice to each member of the multicast via setting  the  multicast  key  on  the  device  and  sending  multicast  RTP  stream  to  pre-configured  multicast address.  By  configuring monitoring  multicast address  on  the  device,  monitor  and  play  the  RTP stream which sent by the multicast address.  MCAST Settings Equipment  can  be  set  up  to  monitor  up  to  10  different  multicast  addresses,  used  to  receive  the multicast RTP stream sent by the multicast address. Here are the ways to change equipment receiving multicast RTP stream processing mode in the Web interface: set the ordinary priority and enable page priority.  Priority: In the drop-down box to choose priority of ordinary calls the priority, if the priority of the incoming flows of multicast RTP, lower precedence than the current common calls, device will automatically ignore the  group RTP  stream.  If  the priority  of the incoming flow of  multicast  RTP  is  higher than  the  current common  calls  priority,  device  will  automatically  receive  the  group  RTP  stream,  and  keep  the  current common  calls  in  state.  You  can  also  choose  to  disable  in  the  receiving  threshold  drop-down  box,  the device will automatically ignore all local network multicast RTP stream.   The options are as follows:  1-10: To definite the priority of the common calls, 1 is the top level while 10 is the lowest  Disable: ignore all incoming multicast RTP stream    Enable the page priority: Page priority determines the device how to deal with the new receiving multicast RTP stream
[键入文字]          36 / 51   when  it  is  in  multicast  session  currently.  When  Page  priority  switch  is  enabled,  the  device  will automatically ignore the low priority multicast RTP stream but receive top-level priority multicast RTP stream,  and  keep  the  current  multicast  session  in  state;  If  it  is  not  enabled,  the  device  will automatically ignore all receiving multicast RTP stream.  Web Settings:  The multicast SS priority is higher than that of EE, which is the highest priority. Note: when pressing the multicast key for multicast session, both multicast sender and receiver will beep. Listener configuration   Blue part (name)     "Group 1","Group 2" and "Group 3" are your setting monitoring multicast name.The group name will be displayed on the screen when you answer the multicast. If you have not set, the screen will display the IP: port directly.  Purple part (host: port)     It is a set of addresses and ports to listen, separated by a colon.  Pink part (index / priority) Multicast is a sign of listening, but also the monitoring multicast priority. The smaller number refers to higher priority.  Red part (priority)    It is the general call, non multicast call priority. The smaller number refers to high priority. The followings will explain how to use this option:  The purpose of setting monitoring multicast "Group 1" or "Group 2" or "Group 3" launched a multicast call.
[键入文字]          37 / 51    All equipment has one or more common non multicast communication.  When you set the Priority for the disable, multicast any level will not answer, multicast call is rejected.  when you set the Priority to a value, only higher than the priority of multicast can come in, if you set the Priority is 3, group 2 and group 3 for priority level equal to 3 and less than 3 were rejected, 1 priority is 2 higher than ordinary call priority device can answer the multicast message at the same time, keep the hold the other call.  Green part (Enable Page priority) Set whether to open more priority is the priority of multicast, multicast is pink part number. Explain how to use:  The purpose of setting monitoring multicast "group 1" or "3" set up listening "group of 1" or "3" multicast address multicast call.  All equipment has been a path or multi-path multicast phone, such as listening to "multicast information group 2".  If multicast is a new "group of 1", because "the priority group 1" is 2, higher than the current call "priority group 2" 3, so multicast call will can come in.  If multicast is a new "group of 3", because "the priority group 3" is 4, lower than the current call "priority group 2" 3, "1" will listen to the equipment and maintain the "group of 2".  Multicast service  Send: when configured ok, our key press shell on the corresponding equipment, equipment directly into the Talking interface, the premise is to ensure no current multicast call and 3-way of the case, the multicast can be established.  Lmonitor: IP port and priority configuration monitoring device, when the call is initiated and incoming multicast, directly into the Talking interface equipment.
[键入文字]          38 / 51   e) Action URL   Action URL Event Settings URL for various actions performed by the phone. These actions are recorded and sent as xml files to the server. Sample format is http://InternalServer /FileName.xml  f) Time/Date
[键入文字]          39 / 51     Time/Date Field Name   Explanation   Network Time Server Settings Time Synchronized via SNTP Enable time-sync through SNTP protocol Time Synchronized via DHCP Enable time-sync through DHCP protocol Primary Time Server Set primary time server address Secondary Time Server Set secondary time server address, when primary server is not reachable, the device will try to connect to secondary time server to get time synchronization. Time zone Select the time zone Resync Period Time of re-synchronization with time server Date Format Date Format Select the time/date display format Daylight Saving Time Settings Location Select the user's time zone specific area DST Set Type Select automatic DST according to the preset rules of DST, or the manually input rules Offset The DST offset time Month Start The DST start month Week Start The DST start week Weekday Start The DST start weekday Hour Start The DST start hour Month End The DST end month
[键入文字]          40 / 51   Week End The DST end week Weekday End The DST end weekday Hour End The DST end hour Manual Time Settings The time set by hand, need to disable SNTP service first.  (5) EGS Access    EGS Access Field Name   Explanation   Import Access Table Click the <Browse> to choose to import remote access list file (access List.csv) and then clicking <Update> can batch import remote access rule.
[键入文字]          41 / 51   Access Table According to entrance guard access rules have been added, you can choose single or multiple rules on this list to delete operation. Add Access Rule Name(necessary) User name Location Virtual extension number, used to make position call instead of real number. It might be taken with unit number, or room number. ID RFID card number. You can manually fill in the first 10 digits of the card number or select the existing card number Number User phone number   Card State Enable or disable holder's RFID card Fwd Number Call forwarding number when above phone number is unavailable.   Department Card holder's department Access Code 1/ When the door phone answers the call from the corresponding <Phone Num> user, then the <Phone Num> user can input the access code via keypad to unlock the door remotely. 2/ The user’s private password should be input via keypad for local door unlocking. The private password format is Location*Access Code. Position Card holder's position Double Auth When the feature is enabled, private password inputting and RFID reading must be matched simultaneously for door unlocking. Type Host: the door phone would answer all call automatically. Guest: the door phone would ring for incoming call, if the auto answer is disabled. Profile It is valid for user access rules (including RFID, access code, etc) within corresponding time section. If NONE is selected, the feature would be taken effect all day. Profile Setting Profile There are 4 sections for time profile configuration Profile Name The name of profile to help administrator to remember the time definition Status If it is yes, the time profile would be taken effect. Other time sections not included in the profiles would not allow users to open door Start Time The start time of section End Time The end time of section Administrator Table Add Admin Card You should input the top 10 digits of RFID card numbers. for example, 0004111806, selected the type of admin card , click <add>. Type: Issuer and revocation When entrance guard is in normal state, swipe card (issuing card) would make entrance guard into the
[键入文字]          42 / 51   issuing state, and then you can swipe a new card, which the card would be added into the database; when you swipe the issuing card again after cards added done, entrance guard would return to normal state. Delete card operation is the same with issuing card. The device can support up to 10 admin cards, 1000 copies of ordinary cards. Note: in the issuing state, swiping deleted card is invalid. Shows the ID, Issuing Date and Type of admin card Delete Clicking <Delete> would delete the admin card list of the selected ID cards. Delete All Click <Delete All>, to delete all admin card lists.   (6) EGS Logs According to open event log, can record up to 20W open event, after more than cover the old records.    Right click on the links to select save target as the door log can export CSV format.  Field Name   Explanation   Door Open Log Result Show the results of the open the door (Success or Failed) Time Open the door of time. Duration Duration of open the door. Access Name If is the open the door for slot card or remote, will display remote access the name. Access ID 1. If open the door way to brush card shows card number 2. If the door way to open the door for the remote display the phone number of the door. 3. If open the door way to open the door for local, no display information. Type Open type: 1. local, 2. Remote, 3. Brush card (Temporary Card, Valid Card and Illegal Card). Note: there are three kinds of credit card feedback results. 1. Temporary Card (Only add the card number, without adding other rules )   2. Valid Card (Has been added access rules) 3. Illegal Card (Did not add information)
[键入文字]          43 / 51   (7) Function Key    Key Event Set the key type to the Key Event.   Type Subtype Usage   Key Event None No responding Dial Dialing function Release Delete password input, cancel dialing input and end call OK identification key   Hot Key Enter the phone number in the input box, when you press the shortcut key, equipment will dial set telephone number. This button can also be used to set the IP address, press the shortcut key IP direct dial call.
[键入文字]          44 / 51   Type Number Line Subtype Usage  Hot Key  Fill the called party’s SIP account or IP address The SIP account corresponding lines Speed Dial   Using Speed Dial mode together with , can define whether this call is allowed to be hung up by re-pressing the speed dial key. Intercom   In Intercom mode, if the caller’s IP phone supports Intercom feature, the device can automatically answer the Intercom calls   Multicast Multicast function is launched will voice messages sent to set the multicast address, all equipment to monitor  the  group  multicast  address  can  receive  sponsors  speech  information,  etc.  Using  multicast functionality can be simple and convenient to send notice to each member in the multicast. Through the DSS Key configuration multicast calling WEB is as follows:   Type Number Subtype Usage Multicast     Set the host IP address and port number, the middle separated by a colon G.711A Narrowband speech coding (4Khz) G.711U G.722 Wideband speech coding (7Khz) G.723.1 Narrowband speech coding (4Khz) G.726-32 G.729AB   operation mechanism Device through the DSS Key configuration of multicast address and port and started coding; set by WEB to monitor the multicast address and port; device sends a multicast, listens to the address of the device can receive the multicast content.  calling configuration The call is already exists, and three party or initiated multicast communication, so it will not be able to launch a new multicast call.
[键入文字]          45 / 51   V. Appendix 1. Technical parameters Communication protocol SIP 2.0(RFC-3261) Main chipset Broadcom Keys DSS Key 1(Stainless steel) Numeric keyboard Support Audio MIC 1 Speaker 3W/4Ω Volume control Adjustable Full duplex speakerphone Support (AEC) Speech flow Protocols RTP Decoding G.729、G.723、G.711、G.722、G.726 Ports Active Switched Output 12V/700mA DC WAN 10/100BASE-TX s Auto-MDIX, RJ-45 RFID/IC card reader EM4100 (125Khz)   MIFARE One(13.56Mhz)   Power supply mode 12V / 1A DC or PoE PoE PoE 802.3af (Class 3 - 6.49~12.95W) Cables CAT5 or better Shell Material Metal panel, ABS face-piece and back shell Working temperature -10°C to 60°C Working humidity 10% - 90% Storage temperature -40°C to 70°C Installation way Wall-mounting External size 160 x 93 x 35mm Package size 209 x 118 x 64mm Gross weight 420g
[键入文字]          46 / 51   2. Basic functions  2 SIP Lines  PoE Enabled  Full-duplex speakerphone (HF)  Numeric keypad (Dial pad or Password input)  Intelligent DSS Keys (Speed Dial/intercom etc)  Wall-mounting  Integrated RFID Card reader  1 indoor switch interface  1 electric lock relay  External power supply  Door phone: call, password, RFID card, indoor switch  Protection level: IP65,CE/FCC  3. Schematic diagram            MIC Numeric keypad (password or dialing)  DSS key with LED Speaker Lock status Call and Ring status Network and Registration status RFID area
[键入文字]          47 / 51   VI. Other instructions 1. Open door modes  Local control 1) Local Password  Set <Local Password> (the password is "6789" by default) via DOOR PHONE\DOOR PHONE as above.  Input password via keypad and press the "#" key, then the door will be unlocked. 2) Private access code  Set <Add Access Rule\Access Code> and enable local authentication.  Input access code via keypad and press the "#" key, then the door will be unlocked.  Remote control 1) Visitors call the owner  Visitors can call the owner via position speed dial or phone number. (After setting the speed dial key, visitors can press it to call direct.)  The owner answers the call and presses the "*" key to unlock the door for visitors. 2) Owner calls visitors  Owner calls visitors via SIP phone.  SIP door phone answers the call automatically.  Owner inputs corresponding <Access codes> via SIP phone keypad to unlock the door.  Swiping cards  Use pre-assigned RFID cards to unlock the door, by touching RFID area of the device.  Indoor switch  Press indoor switch, which is installed and connected with the device, to unlock the door.   2. Management of card 1) Administrator Table <Issuer> and <Revocation>
[键入文字]          48 / 51     Add Administrator cards Input a card’s ID, selected <Issuer> or <Revocation> in the types and Clicked <Add>, you can add administrator card.   Delete Administrator cards Select the admin card of need to delete, click <Delete>.   2) Add user cards  Method 1: used to add cards for starters typically  In web page < EGS Setting →Features →Card Reader Working Mode > option, select <Card Issuing>.   Click <Apply>, Card Reader would be entered the issuing status.  Use new card to touch card reader induction area, and then you might hear the confirmed indication tone from the device. Repeat step can to add more cards.  In web page < EGS Setting →Features →Card Reader Working Mode > option, select <Normal>.
[键入文字]          49 / 51    Click <Apply>, Card Reader would be back to the Normal status.  The issuing records can be found from the door card table list.   Methods 2: used to add cards for professionals  Use <Issuer admin card> to touch card reader induction area, and it would be entered issuing card status.  Use new card to touch card reader induction area, and you might hear the confirmed indication tone from the device. Repeat step 2 to add more cards.  Use  <Issuer  admin  card>  to  touch  card  reader  induction  area  again,  it  would  be  back  to  normal working status.   Method 3: use to add few cards  Input cards number in <EGS Setting\Add Access Rule\ID> page, and then click <Add>  Note: you can also use the USB card reader connected with PC to get cards ID automatically.   Only need to input the top 10 numbers.
[键入文字]          50 / 51   3) Delete user cards  Method 1: used to batch delete cards for starters.  In web page < EGS Setting →Features →Card Reader Working Mode > option, select <Card Revoking>.   Click <Apply>, Card Reader would be entered the revoking status.  Use card to touch card reader induction area, and you might hear the card reader confirmed indication tone. Repeat step can to delete more cards.  In web page <EGS Setting →Features →Card Reader Working Mode >option, select <Normal>.   Click <Apply>, Card Reader would be back to the Normal status.   Method 2: used to batch add cards for intermediates.  Use < Revocation admin card> to touch card reader induction area, and it would be entered revoking card status.  Use the cards you want to delete from system, to touch card reader induction area, and you might hear the card reader confirmed indication tone. Repeat step 2 to delete cards.  Use <Revocation admin card> to touch card reader induction area, and it would be back to card read only status.   Method 3: use to bulk delete or partially delete card records  In web page<EGS Cards →Door Card Table>select the card ID and then click <Delete>. Note: If you click <Delete All>, system will delete all the ID card records.