Farpointe Data DELTA-A RFID Reader User Manual

Farpointe Data Inc. RFID Reader

User manual

Delta Multi-Technology Readers: Quick Reference Guide                                                                2177 Leghorn Street                                              01609-001 Rev 1.0                                                               Mountain View, CA  94043-1605     USA                                      1 of 2                                                                Tel: +1-650-964-2615     Fax: +1-650-988-6687                                                                 Web: http://www.farpointedata.com    E-mail: sales@pyramidseries.com The Delta multi-technology models include the Delta3, Delta5, Delta5.3, and Delta 6.4.    All Delta multi-technology readers are compliant with the following organizations:           FCC compliance Statement: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  The user is cautioned that making changes not approved by Farpointe Data may void the user's authority to use this equipment.  1.0 Cable Requirements All readers operate at up to 500 feet (152 m) of cable, using nine-conductor, shielded, stranded cable.  Per the Security Industry Association’s Wiegand specification, AWG 24 (such as Belden 9539) is the minimum gauge required for data transfer in a 500-foot run length.  However, the proper wire gauge must be determined by the current draw requirements of the reader, the length of the cable run, and the voltage applied to the reader.  If the reader is to be operated at 5 VDC, 5 VDC must be available at the reader (long cable runs have a voltage drop due to the resistance in the cable).  A larger gauge of wire (having less resistance) or a separate power supply near the reader may be required to ensure 5 VDC is available at the reader.  2.0 Delta Multi-Technology Credential Compatibility Delta multi-technology readers are capable of reading both 13.56 MHz and 125 kHz RFID credentials. Operating at 13.56 MHz the reader can read all ISO 14443 Type A contactless smartcard credentials (some are card serial number (CSN) only) and some ISO 14443 Type B contactless smartcard credentials. These credentials include Mifare 1K/4K (secure sectors or CSN), Mifare Ultralight (CSN only), Mifare DESfire (CSN Only), and both Type A and Type B PIV credentials (FIPS-201 compliant). Operating at 125 kHz Delta multi-technology readers can optionally read Pyramid, HID, and/or AWID 125 kHz proximity credentials. 125 kHz reading capability can be disabled if desired.  3.0 Contactless Smartcard Reader Modes Delta multi-technology readers can be configured to read contactless smartcards in any of the following modes: • Sector Plus CSN Mode: Reader looks for access control data in a secure sector but if none is found the reader outputs the card’s CSN instead.  This is the default mode. • Sector Only Mode: Reader looks for access control data in a secure sector but if no valid data is found the reader outputs nothing.   • CSN Only Mode: Reader does not look for access control data in a secure sector and simply outputs the card’s CSN.  4.0 14443 Type A CSN Output Formats Delta multi-technology readers can be configured to output 14443 Type A CSNs in any of the following ways:   • 32-bit Wiegand:  The reader outputs the 32-bit CSN as Wiegand data starting with the MSB.  This is the default mode. • 26-bit Wiegand:  The reader outputs 26-bit Wiegand data comprised of the 16 lower bits of the 32-bit CSN, fixed 8-bit facility code, and beginning and ending parity bits. Facility code defaults to 001 (Note: cutting off 16 MSBs from CSN can cause card duplication). • 34-bit Wiegand:  The reader outputs 34-bit Wiegand data comprised of the 32-bit CSN MSB first plus beginning and ending parity bits. • 40-bit Wiegand:  The reader outputs 40-bit Wiegand data comprised of the 32-bit CSN followed by an 8-bit check sum. • Magnetic Stripe (ABA Track II, clock and data, with card present): CSN is output in ABA Track II format.  5.0 Secure Sector Access Control Data Output Formats Customer specified access control data programmed onto a secure Mifare 1K or 4K sector can be output in any of the following ways: • Wiegand (industry standard 26-bit Wiegand and custom formats) • Magnetic Stripe (ABA Track II, clock and data, with card present)  6.0 FIPS-201 Output Formats Please see Farpointe Data’s “FIPS-201 Reader Output Selection” document. Default output is 75-bit Wiegand.      Reference Document  Delta Multi-TechnologyReaders
Delta Multi-Technology Readers: Quick Reference Guide                                                                2177 Leghorn Street                                              01609-001 Rev 1.0                                                               Mountain View, CA  94043-1605     USA                                      2 of 2                                                                Tel: +1-650-964-2615     Fax: +1-650-988-6687                                                                 Web: http://www.farpointedata.com    E-mail: sales@pyramidseries.com  7.0 Grounding Shield (drain) continuity must run from the reader to the access panel.  Shield (drain) and reader ground must be tied together at the access panel and connect to an earth ground at one point.  8.0 Power and Voltage Delta multi-technology readers may be powered by the access panel, so the reader is powered on when the access supply is powered on.  However the best case is to power the readers by a separate, linear power supply. Voltage can range from 5 to 14 VDC, 12 VDC is nominal.  9.0 Reader Wiring   10.0 Connections in Detail Wire Color  Line  I/O  Description Red  Reader input voltage  Input  5 to 14 VDC Green  Wiegand data 0/ Magstripe Clock  Output   Wiegand data or ABA Track II clock White  Wiegand data 1/ Magstripe Data  Output   Wiegand data or ABA Track II data Brown  Red LED host control  Input  LED host control.  In single line LED control mode (default mode) pull line low to turn on green LED. In dual line LED mode pull line low to turn on Red LED Orange  Green LED host control  Input  LED host control, only used in dual LED mode.  In dual LED mode pull line low to turn on green LED. Blue  Audio tone host control  Input Beeper host control.  Pull line low for beep. Purple  Read mode control  Input  Read mode host control.  Pull line low for “Sector Only” mode. Yellow  Card Present  Output (can be configured as TTL or open collector) Card present line for ABA Track II magnetic stripe output. Black  Reader Ground  Input  Reader Ground Silver  Cable shield  N/A  Cable shield (drain), must be grounded  Wire ColorFunctionGreenBlueRedPurpleBrownShield (Drain)WhiteYellowBlackSilverData 0BeeperReader PowerRead ModeLED line 1LED line 2Data 1Card PresentReader GroundOrangeFigure 1: Wiring Connections to Access Panel Access Panel      Reference Document  Delta Multi-TechnologyReaders

Navigation menu