Farpointe Data P900 RFID Reader User Manual Pyramid Series Reader Installation Guide 1 4

Farpointe Data Inc. RFID Reader Pyramid Series Reader Installation Guide 1 4

User manual

Download: Farpointe Data P900 RFID Reader User Manual Pyramid Series Reader Installation Guide 1 4
Mirror Download [FCC.gov]Farpointe Data P900 RFID Reader User Manual Pyramid Series Reader Installation Guide 1 4
Document ID928294
Application ID2jUwrJkg8wukkKIeGSTYMA==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize62.65kB (783177 bits)
Date Submitted2008-04-15 00:00:00
Date Available2008-04-16 00:00:00
Creation Date2005-11-13 17:18:28
Producing SoftwareAcrobat Distiller 6.0.1 (Windows)
Document Lastmod2008-03-28 16:29:29
Document TitlePyramid-Series-Reader-Installation-Guide_1-4.fm
Document CreatorAdobe Illustrator CS2
Document Author: Greg

Farpointe Data Readers
NOTE: Installation and performance of a Pyramid Series Reader with HID or AWID compatibility (on
operational features) is identical to standard Pyramid Series Readers.
All Farpointe Data Readers are compliant with the following organizations:
FCC compliance Statement: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Installation Guide
This Installation Guide is intended for experienced installing technicians. It is a basic reference to ensure all
connections are properly made. See the appropriate Product Manual for detailed information on installing
Pyramid Series Readers or Cobra Readers (such as the P-300, P-500, P-640, P-700, P-900 or EM-30, EM-50,
EM-64). These documents may be downloaded from the Farpointe Data website found at
www.pyramidseries.com; under Support > Technical Documents.
The user is cautioned that making changes not approved by Farpointe Data may void the user's authority to use this equipment.
Product can be used without license conditions or restrictions in all European Union countries, including Austria, Belgium, Bulgaria, Cyprus,
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands,
Poland, Portugal, Romania, Slovakia, Spain, Sweden, United Kingdom, as well as other non-EU countries, including Iceland, Norway, and
Switzerland.
1.0
Cable Requirements
All readers operate at up to 500 feet (152 m) of cable, using seven-conductor, shielded, stranded cable. Per
the Security Industry Association’s Wiegand specification, AWG 24 (such as Belden 9537) is the minimum
gauge required for data transfer in a 500-foot run length. However, the proper wire gauge to use must be
determined by the current draw requirements of the reader, the length of the cable run, and the voltage
applied to the reader.
2.0
Output Formats
3.0
Grounding
4.0
Power
5.0
Voltage
•
•
Wiegand (industry standard 26-bit Wiegand and custom Wiegand formats)
Magnetic Stripe (ABA Track II, clock and data, with card present)
Shield (drain) continuity must run from the reader to the access panel. Shield (drain) and reader ground
must be tied together at the access panel and connect to an earth ground at one point.
A reader may be powered by the access panel, so the reader is powered on when the access panel is
powered on. However the best case is to power the reader by a separate, linear power supply.
•
Proximity Readers
If the reader is to be operated at 5 VDC, 5 VDC must be available at the reader (long cable runs have a voltage drop due to the resistance in the cable). A larger gauge of wire (having less resistance) or a separate
power supply near the reader may be required to ensure 5 VDC is available at the reader.
Typically 5 to 14 VDC
2177 Leghorn Street
01506-001 - Rev. 1.5
Mountain View, CA 94043-1605
USA
1 of 2
Tel: +1-650-964-2615
Fax: +1-650-988-6687
Web: www.pyramidseries.com
E-mail: sales@pyramidseries.com
Farpointe Data
Installation Guide
6.0
Reader Wiring
Figure 1: Wiring Connections for Wiegand Output
7.0
Troubleshooting the Reader Installation
Problem
The reader does not recognize a card/tag (no beep, no
LED flash)
Proximity Readers
Figure 2: Wiring Connections for Magnetic Stripe Output
The reader has a short read
range.
Possible Cause
C orrective Actio n
1.
One or more of the reader’s wiring connections are incorrect
Power down the reader/access panel and verify the wiring
connection are correct for the reader/access panel combination.
2.
The reader is not receiving
proper power from the access
panel
Verify the voltage supplied to the reader is between 5 and
3.
The reader is mounted too close
to a device that radiates electromagnetic interference
Devices such as computer monitors radiate electromagnetic interference that affects read range. When possible,
relocate either the reader or the device to provide greater
separation between the two.
4.
You are using an incorrect type
of card.
Make sure you are using an access card that is compatible
with the reader.
1.
The reader/access panel is not
properly grounded.
Ensure there is a quality earth ground connection made to
the access panel. Refer to the access panel’s documentation for information regarding the earth ground connection.
2.
The shield wire for the reader’s
cable has opened somewhere
between the reader and the
access panel.
Verify the shield line from the access panel to the reader is
one continuous, connected line. Refer to the access panel’s
documentation and verify the shield line is correctly connected to the access panel.
3.
The reader is mounted too close
to a device that radiates electromagnetic interference.
Devices such as computer monitors radiate electromagnetic interference that affects read range. When possible,
relocate either the reader or the device to provide greater
separation between the two.
4.
The power supply is generating
electromagnetic interference
The power supply on the access panel must be a regulated, linear supply. Do not use switching supplies as they
are often sources of electromagnetic interference.
14 VDC.a
a. A supply voltage of 12 VDC at the reader is recommended for best operation.
NOTE: The user is cautioned that making changes not approved by Farpointe Data may void the user's authority to use this equipment.
Products covered by patent number 6,611,198, 6,411,199 and D417,443. Other patents pending may apply.
2177 Leghorn Street
01506-001 - Rev. 1.5
Mountain View, CA 94043-1605
USA
2 of 2
Tel: +1-650-964-2615
Fax: +1-650-988-6687
Email: sales@pyramidseries.com
web: www.farpointedata.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Tagged PDF                      : Yes
Page Mode                       : UseOutlines
XMP Toolkit                     : 3.1.1-111
About                           : uuid:0c47ed9d-9d7a-497f-a89f-e1a3d0fd2e94
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Create Date                     : 2005:11:13 17:18:28Z
Creator Tool                    : Adobe Illustrator CS2
Modify Date                     : 2008:03:28 16:29:29-07:00
Metadata Date                   : 2008:03:28 16:29:29-07:00
Thumbnail Width                 : 188
Thumbnail Height                : 256
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 22311 bytes, use -b option to extract)
Document ID                     : uuid:13432f41-397d-49a8-9c49-8405f6166184
Instance ID                     : uuid:a055a0b4-c1e6-4fa5-9d37-2200187a200c
Format                          : application/pdf
Creator                         : Greg
Title                           : Pyramid-Series-Reader-Installation-Guide_1-4.fm
Page Count                      : 2
For                             : Francisco Alcala, Farpointe Data, Inc.
Bounding Box                    : 50 27 581 761
Container Version               : 9
Creator Version                 : 12
Author                          : Greg
Image Height                    : 734
Image Width                     : 531
Image Size                      : 531x734
Megapixels                      : 0.390
EXIF Metadata provided by EXIF.tools
FCC ID Filing: T8I-P900

Navigation menu