Fego Precision Co RF152 Oscillating Fan Remote Control User Manual

Fego Precision Industrial Co Ltd Oscillating Fan Remote Control Users Manual

Users Manual

Download: Fego Precision Co RF152 Oscillating Fan Remote Control User Manual
Mirror Download [FCC.gov]Fego Precision Co RF152 Oscillating Fan Remote Control User Manual
Document ID835439
Application IDlR39CRdNkBR3+nbwLj8RAA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize47.33kB (591590 bits)
Date Submitted2007-08-29 00:00:00
Date Available2007-08-29 00:00:00
Creation Date2007-08-02 15:44:41
Producing SoftwareAcrobat PDFWriter 5.0Windows NT ª©
Document Lastmod2007-08-24 11:48:01
Document TitleE:\FILE_SRV3\產品資料\中山宇森\
Document CreatorAdobe PageMaker 6.5C - [E:\FILE_SRV3\產品資料\中山宇森\RF136觸控上下燈\RF152說明書.p65]
Document Author: duckss

POWER RATING:
BLACK (TO MOTOR L) to wire from fan
IMPORTANT: Follow these steps to insure proper
120V/60Hz
ORANGE (FOR UP LIGHT) to wire from fan.
installation and operation
IMPORTANT SAFETY PRECAUTIONS
LIGHT: 300W MAX
BLUE (FOR DOWN LIGHT) to wire from fan.
Install your ceiling fan by the wiring diagram provided
WARNING: To avoid electrical shock, be sure that
FAN: 85W (MAX)
with the fan without the receiver in place.
electricity has been turned off at the circuit breaker or
Turn on electrical power at the circuit breaker or fuse
fuse box before wiring
PREFER: connect the ceiling to a power switch in
box. Turn wall switch‘’ON’’.
ALL wiring must be in accordance with the National
the power line to get the flip switch control
Set your ceiling fan to HIGH speed with its pull chain
Electrical Code and local electrical codes. A qualified
function.
Control. Do not adjust the ceiling fan pull chain after this
electrician should perform electrical installation.
3. Complete ceiling fan installation and assembly
Step.
according to its provided instruction.
Turn on light kit (if present)
DO NOT use water or detergents to clean the remote
IMPORTANT: When the frequency code is
Turn wall switch ‘’OFF ‘’
transmitting unit. A dry dust cloth will be suitable for
changed a new code needs to be set by sliding
Turn off electrical power at the circuit breaker or Fuse
most cleaning.
the FREOUENCY CODE SWITCH on the receiver.
box.
Connecting the Receiver
ONLY the flip switch and transmitter unit should
1. Disconnect the wires from the ceiling to the fan. TRANSMITTER OPERATION
change the fan speeds.
ON
Install the receiver to the ceiling fan according to SPEED BOTTON to set the fan speeds.
Light on/off: to toggle set the light on/off.
your mounting type (Figure 1). Be sure the
SECURITY CODE
Do not use the pull chain to change fan speeds after
Dimmer: to set the light power rating. This key function
antenna is positioned so it is exposed when
installation, as damage could result to your remote
SWITCH
canopy is attached. Do not modify or damage the is only when the light is ON.And keep the light key.
control or ceiling fan.
antenna wire as control performance may be
reduced.
DO NOT use the reverse switch when the ceiling fan
NOTICE
2. Use the two larger wire nuts supplied to connect
is operating. This could result in damage to your
THE BATTERY OF THE REMOTE THAT USE THE ALthe receiver and house wiring; then use the three
Remotel control or ceiling fan.
KALINE BATTERY IS BETTER.
small wire nuts supplied to connect the receiver
General information:
and ceiling fan wiring. See Wiring Diagram in
INSTALLATION AND WIRING
15.203 - The transmitter shall not be collocated
Figure 2.
with other transmitters or antennas.
BLACK ‘’AC in L‘’to HOT wire in ceiling
WARNING: To avoid electrical shock, be sure that
WHITE ‘’AC in N‘’to NEUTRAL from ceiling
NOTICE
& 2.1093 - To comply with FCC RF
2.1091
SMART REMOTE
exposure
compliance
requirements,
a separa15.21- Any
changes
or modifications
Ant enna
Receiver
Bracket
tion
of at
least 20 cm
not distance
expressly
approved
bymust
the be maintained
between
antenna
of thisvoid
device
grantee
of thisthedevice
could
theand
ACIN_N(WHITE)
ACIN_L(BLACK)
LOW BATTERY
all
persons.
This Transmitter
user's
authority
to operatemust
the not be
collocated
or
operating
in
conjunction
with any
equipment.
other antenna or transmitter.
ANT ANTENNA
Canopy
Figure1.
electricity has been turned off at the circuit breaker or
fuse box before wiring.
Figure 2.
WHITE (TO MOTOR N) to wire from fan.
PRESET FUNCTION (MEMORY):
If you use the wall switch to turn off the fan, the
speed and lighting level that you previously set will
remain in the remote control’s memory. The next time
electricity is turned on, fan operation will resume at the
same speed and lighting level when you press the FAN
and/or LIGHT key on the remote unit. NOTE For
convenient access and safe keeping of your remote
control unit. Mount near a wall switch by using the
bracket provided.
ON
RF152-1

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-701
Create Date                     : 2007:08:02 15:44:41Z
Creator Tool                    : Adobe PageMaker 6.5C - [E:\FILE_SRV3\產品資料\中山宇森\RF136觸控上下燈\RF152說明書.p65]
Modify Date                     : 2007:08:24 11:48:01+08:00
Metadata Date                   : 2007:08:24 11:48:01+08:00
Format                          : application/pdf
Creator                         : duckss
Title                           : E:\FILE_SRV3\產品資料\中山宇森\
Producer                        : Acrobat PDFWriter 5.0Windows NT ª©
Document ID                     : uuid:bf3197df-b44f-46f7-b112-0151514b3582
Instance ID                     : uuid:3f37d1af-6d73-464b-b1f4-842a5b28815e
Has XFA                         : No
Page Count                      : 1
Author                          : duckss
EXIF Metadata provided by EXIF.tools
FCC ID Filing: M8CRF152

Navigation menu