Feig Electronic EECCOPLUS powerlineECCO+ User Manual

Advanced Panmobil Systems GmbH & Co. KG powerlineECCO+ Users Manual

Users Manual

SCANNDY USER GUIDE Page 1powerlineECCO+ Quick Reference Guide
SCANNDY USER GUIDE Page 2© 2014 by advanced PANMOBIL systems GmbH & Co. KG This manual contains proprietary information of advanced PANMOBIL systems GmbH & Co.  KG.  It  is  intended  solely  for  the  information  and  use  of  parties  operating  and maintaining the equipment described herein. Such proprietary information may not be used, reproduced, or disclosed to any other parties for any other purpose without the expressed written permission of advanced PANMOBIL systems GmbH & Co. KG. Software and product improvement The software is provided strictly on an “as is” basis. The user shall not modify, merge, or corporate any form or portion of a licensed program with other program material, create  a  derivative  work  from  a  licensed  program,  or  use  a  licensed  program  in  a network  without  written  permission  from  PANMOBIL.  The  user  agrees  not  to decompile,  disassemble,  decode,  or  reverse  engineer  any  program  delivered  to  the user  or  any  portion  thereof.  PANMOBIL  reserves  the  right  to  make  changes  to  any software  or  product  to  improve  reliability,  function,  or  design.  PANMOBIL  does  not assume any product liability arising out of, or in connection with, the application or use of  any  product, circuit,  or application  described  herein.  No  license  is  granted,  either expressly  or by  implication, estoppel,  or otherwise under any  PANMOBIL intellectual property rights. An implied license only exists for equipment, circuits, and subsystems contained in PANMOBIL products. Trademarks  PANMOBIL and powerlineECCO+ are registered trademarks. Bluetooth is a registered trademark of Bluetooth SIG. Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation. All other product or service names are the property of their respective owners.  advanced PANMOBIL systems GmbH & Co. KG Hansestraße 91 D-51149 Cologne, Germany Warranty For the complete PANMOBIL hardware product warranty statement, go to: www.PANMOBIL.com
SCANNDY USER GUIDE Page 3PRODUCT REFERENCE powerlineECCO+      Introduction PANMOBIL’s powerlineECCO+ devices capture and store barcode and RFID data for a variety  of  uses,  and  transmit  barcode  and  RFID  data  to  a  host  via  USB  connection, Bluetooth  or  Wi-Fi.  This  document  provides  a  basic  instruction  using  the powerlineECCO+  devices.  For  information  about  settings  and  configurations,  please refer to the product user manual on www.PANMOBIL.com 1 7 8 3 2 4 5 6 8 7 9 12 10 13 11
SCANNDY USER GUIDE Page 4No. Description Function 1 Green  LED  Lights up green when ECCO+ is turned ON. When the battery level is empty, it flashes every 2 sec (Further function can be user defined with the programming interface) 2 Yellow LED Lights up yellow if a barcode or RFID tag was read successfully. Is flashing yellow (500ms) when connected to USB (Further function can be user defined with the programming interface) 3 Red LED  Lights up red if connected to a battery charger (USB or power adapter) Red = Battery charging Off = Battery fully charged 4 Blue LED  Lights up blue when ECCO+ is connected to Bluetooth Is flashing fast (500ms) while Wi-Fi is associated Is flashing blue (3 sec.) when Wi-Fi is connected (Further function can be user defined with the programming interface) 5 Key 1 (Trigger button) Triggers the barcode and/or the RFID reader  (Further function can be user defined by Universal Configurator or with the programming interface) 6 Key 2 (custom) (This function can be configured by using Universal Configurator or with the programming interface) 7 Key  3 (Custom) (This function can be configured by using Universal Configurator or with the programming interface) 8 Key 4 (Custom) Power ON/OFF button (This function can be configured by using Universal Configurator or with the programming interface) Power key to turn the unit ON. Pressing this key for 3 sec. turns the unit OFF 9 Configuration Mode Alternative configuration mode Follow the steps below to set the configuration mode 1. Switch off the device2. Press and hold key 4 and 5 until a beep sound appears (this may take a few seconds)
 SCANNDY USER GUIDE Page 5   3. Connect the device to a computer via USB 4. The device will be mounted as a removable drive “SCANNDY”  5. Open the file “config.ini” or use the Universal Configurator to modify the settings 6. Press button 3 (Trigger) until a beep sound appears  7. The device restarts with the new settings 10 USB protection clip  Mini-USB Interface Rubber clip to protect the Mini USB port  Main communication and battery charging interface 11 RESET Press and hold the keys 5+6+7+8 for 5 seconds to reset the device. !!! Please note !!! By the reset the device loses its timestamp. Before you continue to use it, you must synchronize the time settings by connecting  the device again with the Smart Universal Configurator . The time thereby automatically synchronized with the system time of your PC. Specific configuration settings and data will be not lost by the reset. 12 Scanning window   RFID antenna (option) Protection glass for the barcode and RFID reader. To have the best reading performance, keep the glass clean and free of scratches.  Antenna for RFID reader/writer 13 Clip holder (accessories) Holder to fix the shirt clip, belt clip or neck belt (accessories) 14 Int.  Li-Ion battery Rechargeable Li-Ion battery  1500mAh  CHARGING THE BATTERY  Before the first operation, the main battery should be fully charged by using the included power adapter or through the USB interface of the computer. As long as the battery is charging, the red LED (3) lights solid red. After the battery is fully charged the red LED (3) turns off.
SCANNDY USER GUIDE Page 61. Remove the USB protection clip (9) from the device2. Connect the device to the USB port of a computer or to the USB poweradapter (accessories)3. As long as the battery is charging, the red LED (3) lights solid red4. After the battery is fully charged the red LED (3) turns off.A full recharge of the battery takes approximately 4 to 5 hours when using the included power adapter. Recharging the battery from a USB interface of a computer may take longer. SCANING BARCODE (1D Laser) 1. Aim the scanner on the barcode2. Press the Trigger key (5)3. Ensure that the scanning line is directed straight on the barcode
SCANNDY USER GUIDE Page 7The device beeps and the right LED (2) turns yellow to indicate a successful decode. Take a look at the powerlineECCO+ user guide to see how to define beeps and vibrate alerts by using the Universal Configurator. SCANING BARCODE (1D/2D Imager) 1. Aim the scanner on the barcode2. Press the Trigger button (5)3. The device decodes the barcode closest to the cross center unless youdisable the Pick-List mode (see below) in the 2D cameras.1. Replace the Config.INIPlease download the following file (Right click and "save as"): Config.INI Please copy it to the device and replace the existing .After restart of the device the Pick List Mode is now turned off. 2. Manually change the config file:a. Connect the device to your computerb. Open drive "SCANNDY"c. Open "Config.INI" on the drived. Set Picklist Mode=0e. Save the changesf. Disconnect device from USB and reboot
SCANNDY USER GUIDE Page 8The device beeps and the right LED (2) turns yellow to indicate a successful decode. Take a look at the powerlineECCO+ user guide to see how to define beeps and vibrate alerts by using the Universal Configurator.
 SCANNDY USER GUIDE Page 9   SCANING RFID   1. Aim the scanner on the RFID tag 2. Make sure the tag is within the reader range 3. Press the trigger key (5) to read data of the RFID tag                       The device beeps and the right LED (2) turns yellow to indicate a successful decode. See the powerlineECCO+ user guide to see how to define beeps and vibrate alerts by using the Universal Configurator.
 SCANNDY USER GUIDE Page 10   BLUETOOTH CONNECTION    To pair the  Bluetooth enabled devices to a Bluetooth enabled host  1. Connect the device to the host using the USB port and use the Universal Configurator to set the data output mode to Bluetooth. Select the Bluetooth profile supported by the host or required by the application.  • Serial Port Profile (SPP) - The scanner connects to the host via Bluetooth and emulates a serial connection. The scanner accepts an incoming connection requested by a Bluetooth host.  • Bluetooth Keyboard Emulation (HID) - The scanner connects to the host via Bluetooth and emulates a keyboard. The scanner accepts an incoming connection, requested by a Bluetooth host.  (See the powerlineECCO+ user guide to see how to define beeps and vibrate signals by using the Universal Configurator.)  2. Save the settings and disconnect the device from the computer. On the host computer, launch the third party Bluetooth pairing application and place the application into discover Bluetooth device mode. 3. Select the powerlineECCO+ from the discovered device list. The Bluetooth application may prompt you to scan a passkey it generated, or for you to create one and then scan the pin code. 4. If the Bluetooth application prompts you to generate a pin, enter the configured Bluetooth pin DEFAULT:  1234  5. If the Bluetooth application prompts you to enter the pass key it generated, scan numeric barcodes on page X  and confirm by scanning ENTER 6. The right LED (4) lights constantly blue as long as the device is connected
 SCANNDY USER GUIDE Page 11   NUMMERIC BARCODES FOR BLUETOOTH PAIRING                                                                              6 2  3 4 1 5  7 8  9 0 ENTER
SCANNDY USER GUIDE Page 12Transmitting Barcode and/or RFID data to a host Batch mode All barcodes and RFID data scanned in batch mode are saved in the file “Output.txt” on the removable drive “Scanndy”. Connect the device to the host computer via USB and use the Windows-Explorer to navigate to the device “SCANNDY”. Copy the file “Output.txt” to the host. To delete the data from the device just delete the file “Output.txt”
SCANNDY USER GUIDE Page 13Transmitting data from a Bluetooth or Wi-Fi device When the scanner is paired to a host via Bluetooth, the data transmits to the host after each scanning procedure and is not stored on the scanner unless the scanner moves out of the range of the host. For out of range usage you can configure the device to either store the data in a cache memory or do not allow scanning. If the device was configured to store the out of range captured data, it stores the data in a file Cache.txt. After reconnection, it transmits all cached data to the host. (See the powerlineECCO+ user guide to see how to set the device to cache data by using the Universal Configurator.) Bidirectional communication for Bluetooth and Wi-Fi connected devices For applications that require bidirectional communication between the device and the host. PANMOBIL devices support an embedded communication protocol SCOMP and REMOTE mode. (See the powerlineECCO+ user guide to see how to set the device to use SCOMP protocol and/or REMOTE mode by using the Universal Configurator.) Troubleshooting Problem Possible Solution Device does not turn on Make sure the battery is charged Laser comes on but device does not decode barcode  - Ensure the device is configured to read the type of code being scanned - Ensure the code is not defaced. Try to read another Barcode - Move the device closer to or further from the code. This depends on your Barcode Size The device is ON but does not react on any button  - Press and hold the buttons 5+6+7+8 for 5 seconds to reset the device. !!! Please note !!! By the reset the device loses its timestamp. Before you continue to use it, you must 3
SCANNDY USER GUIDE Page 14synchronize the time settings by connecting - the device again with the Smart Universal Configurator .The time thereby automatically synchronized with the system time of your PC. Specific configuration settings and data will be not lost by the reset. Stored data and configuration are not affected by a reset Bluetooth is not working - Ensure that the device is in the correct       Bluetooth Mode (HID or SPP)  - Ensure that you are paired correct to your host - Renew your pairing at your host system Barcode reading ability has degraded  Please clean your Scan Window with a soft cloth with water. Nothing happens when the Scan Button is pushed - Maybe the scan window has become dirty.  -     Make sure your device is powered on.       (Green LED on the left must be on) - Ensure that your buttons are correctly configured
SCANNDY USER GUIDE Page 15ADVANCED DEVICE CONFIGURATION The powerlineECCO+ config.ini file contains the most common device settings.  For information about the configuration for options like Bluetooth,  UHF RFID as well as Barcode configuration please refer to the document Config_ini.pdf SAFETY AND REGULATORY Interference statement: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Modification statement: The FCC requires the user to be notified that any changes or modifications made to this device and are not explicit approved by advanced PANMOBIL systems GmbH & Co. KG, may void the user’s authority to operate the equipment. Class B digital devices regulatory notice: This equipment has been tested and confirmed to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency, energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. In the case that these devices should disturb your surroundings by their powering on and off, please inform advanced PANMOBIL systems GmbH & Co. KG immediately and the user is encouraged to try to correct the interference by one or more of the following measures: ·Reorient or relocate the receiving antenna·Increase the separation between the equipment and receiver·Connect the equipment into an outlet on a circuit different from that to which thereceiver is connected to ·Consult the dealer or an experienced radio or television technician for help
 SCANNDY USER GUIDE Page 16   Wireless notice  This product emits radio frequency energy, but the radiated output power of this device is far below the FCC radio frequency exposure limits. Nevertheless, the device should be used in such a manner that the potential for human contact with the antenna during normal operation is minimized. The system antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.  EU: This equipment is intended to be commercialized in all the countries of the European Union and there is no commercialization or operational restrictions in any of the countries. Hereby, advanced PANMOBIL systems GmbH & Co. KG declares that this Bluetooth barcode scanner is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC    European countries, where this equipment can be used are : Austria (AT) - Belgium (BE) - Bulgaria (BG) - Switzerland/Liechtenstein (CH) - Cyprus (CY) - Czech Republic (CZ) - Germany (DE) – Denmark (DK) - Estonia (EE) - Finland (FI) - France (FR) - Greece (GR) - Hungary (HU) - Ireland (IE) - Iceland (IS) - Lithuania (LT) – Luxembourg (LU) - Latvia (LV) - Malta (MT) - Netherlands (NL) - Norway (NO) - Portugal (PT) - Romania (RO) - Sweden (SE) - Slovenia (SI) – Slovak Republic (SK) - United Kingdom (UK)-Italy (IT)-Poland (PO)-Spain (SP).  Laser notice Use of controls or adjustments or performance of procedures other than those specified herein may result in exposure to hazardous visible laser light. The laser scanner utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known biological damage, avoid staring into the beam as one would with any very strong light source, such as sunlight. Avoid that the laser beam hits the eye of an observer, even through reflective surfaces like mirrors, etc.  The following information is shown on the laser scanner device class label:
SCANNDY USER GUIDE Page 17Limited Warranty The manufacturer warrants that the product will be free of defects in material and workmanship for 2 years from the date of shipment. The manufacturer will, either repair or replace the defective products. These reparations or replacements the manufacturer accepts completely within the warranty. It is the manufacturers option if the products will be exchanged, repaired or replaced. All other costs associated with shipment, warranty payments, freight, insurance and charge fees are the buyers responsibility. The  manufacturer will pay the freight costs (duties, insurance, customs and any other fees) associated with the return shipment to the buyer. The method of shipment will be at the manufacturers discretion. The reparation or the replacement of any parts or equipment does not extend the period of warranty provided before.   THIS LIMITED WARRANTY APPLIES ONLY TO THE MANUFACTURER'S WARRANTY. THE MANUFACTURER MAKES NO WARRANTY OF MERCHANTABILITY OR THE  PREFORMANCE OF A PARTICULAR USE OF THE PRODUCT.  To take advantage of this warranty, buyer should contact the seller and not the manufacturer. The manufacturer's warranty does not apply if the equipment has been caused damage by an accident, transportation, neglect, misuse, change, modification or attempted improvements to the product. Furthermore damage caused by installations, the contact surfaces, mounting, programs or due to false, erroneous use of the device for which it was not intended. Problems related to battery power, are not included in the warranty.  Declaration of conformity These devices has  been  tested and  found to  comply with  the limits  for  a class B  digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not in-stalled and used in accordance with the instructions, may  cause  harmful  interference  to  radio  communications.  The  appearance  of  disturbance  in particular  installations  is  not  excluded.  In  the  case  that  these  devices  should  disturb  your surroundings by their powering on and off, please inform advanced PANMOBIL systems GmbH & Co. KG immediately. The  user  is  cautioned  that  any  changes  or  modifications  not  expressly  approved  by  advanced PANMOBIL systems GmbH & Co. KG could void the user's authority to operate the equipment.
SCANNDY USER GUIDE Page 18Consumer electronics These devices has been tested and found to comply with the limits for class B digital devices, pursuant to the CE EMC directive. For more information, please contact us at:  advanced PANMOBIL systems GmbH & Co. KG Hansestrasse 91 51149 Cologne E-mail: info@panmobil.com Notice : The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user’s authority to operate the device.This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Navigation menu