Feig Electronic MLL02 Inductive Tag Reader User Manual megalock l manual

Feig Electronic GmbH Inductive Tag Reader megalock l manual

Users Manual

INSTALLATIONfinalpublic2004-10-06megalock-l-manual.DOCOBID®Cabinet Lockmegalock-lup from Firmware 4.00 (with real time clock)(1)(2)Fig.  1: megalock-l layout right (layout left = mirror image)(1) Recommended door hole diameter 23 mm(2) max. door thickness 21.5 mm
OBID®megalock-lInstallationFEIG ELECTRONIC GmbH Page 2 of 14 megalock-l-manual.DOCNote Copyright 1998 - 2004 byFEIG ELECTRONIC GmbHLange Strasse 4D-35781 Weilburg-WaldhausenTel.: +49 6471 3109-0http://www.feig.deWith the edition of this document, all previous editions become void. Indications made in this manual may bechanged without previous notice.Copying of this document, and giving it to others and the use or communication of the contentsthereof are forbidden without express authority. Offenders are liable to the payment of damages. Allrights are reserved in the event of the grant of a patent or the registration of a utility model or design.Composition of the information in this document has been done to the best of our knowledge. FEIGELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manualand may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all ourefforts, errors may not be completely avoided, we are always grateful for your useful tips.The instructions given in this manual are based on advantageous boundary conditions. FEIG ELECTRONICGmbH does not give any guarantee promise for perfect function in cross environments.FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this documentand makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not conveyany license under its patent rights nor the rights of others.OBID® is a registered trademark of FEIG ELECTRONIC GmbH.
OBID®megalock-lInstallationFEIG ELECTRONIC GmbH Page 3 of 14 megalock-l-manual.DOCContents1.  Safety and warning notices – read before commissioning ............................................42.  Basic functions of the megalock-l..........................................................................................52.1.  Locking the megalock-l.........................................................................................................52.2.  Unlocking the megalock-l......................................................................................................53.  Installation....................................................................................................................................64.  Start-up procedure ....................................................................................................................64.1.  Function testing with the "TestKey"......................................................................................64.2.  Configuring the megalock-l with the "SetupKey" ...............................................................74.3.  Configuring for standard/daylight saving time "DSTKey"..................................................84.4. . Setting time of day and date "ClockSetKey" .....................................................................85.  Resetting a megalock-l with the "ResetKey"....................................................................106.  Replacing a megalock-l...........................................................................................................107.  Battery.........................................................................................................................................117.1.  Battery replacement.............................................................................................................118.  Service / Maintenance.............................................................................................................11ANNEX A Technical Data ............................................................................................................12ANNEX B:........................................................................................................................................13Europe (CE)..................................................................................................................................13USA (FCC)....................................................................................................................................13ANHANG C: LED Blink-Codes...................................................................................................14
OBID®megalock-lInstallationFEIG ELECTRONIC GmbH Page 4 of 14 megalock-l-manual.DOC1. Safety and warning notices – read before commissioning• The device may only be used for the purpose intended by the manufacturer.• The operating instructions have to be handed out to every user and kept in an easily accessibleplace.• Unacceptable changes as well as the use of spare parts and special features which are notsold or recommended by the manufacturer, may cause fire, electric shocks  and injuries.Therefore, such measures lead to nonliability of the manufacturer and a lapse of all warrantyclaims.• The appliance is subject to the manufacturer’s guarantee regulations in the version valid at thetime of purchase. We cannot be held liable for improper or faulty manual or automatic adjust-ment of parameters resp. improper use of the appliance.• Repair work may only be carried out by the manufacturer.• The user has to make sure that the appliance is installed and operated according to the techni-cal rules of the country of installation as well as other regional regulations.
OBID®megalock-lInstallationFEIG ELECTRONIC GmbH Page 5 of 14 megalock-l-manual.DOC2. Basic functions of the megalock-l(1) Rotary knob:With integrated LED display (red / green) and antenna for exchangebetween megalock-l and megaKey.(2) Battery compartment:Use special screwdriver to open (Type: ID MS.SSD-A).  2.1. Locking the megalock-l1. Push rotary knobmegalock-l is activated for 8 sec. (no indicator)2. Present megaKey:The green LED flashes for a max. of 8 sec. As longas the green LED is flashing, the rotary knob can beturned 90° and the megalock-l locked.3. Rotate knob 90°Turning the knob locks the megalock-l, whichacknowledges this by turning on the green LED forseveral seconds.2.2. Unlocking the megalock-l1. Push rotary knobmegalock-l is activated for 8 sec. (no indicator)2. Present megaKey:As soon as a valid megaKey is recognized by themegalock-l the green LED begins to flash and the rotaryknob turns itself back to „unlocked“ position.
OBID®megalock-lInstallationFEIG ELECTRONIC GmbH Page 6 of 14 megalock-l-manual.DOC3. InstallationInstalling:The electronic cabinet lock megalock-l is attached on the inside of a cabinet door usingfour screws.Start-up:Once the installation work is complete and all the locks tested, they are configured ac-cording the star-up procedure.Applying the reference plate:Stick the user reference plate only to a flat, grease- and dust-free surface.4. Start-up procedureThe following Start-up procedure is recommended.4.1. Function testing with the "TestKey"Lock megalock-l:1. Activate megalock-l  (push rotary knob)2. Hold TestKey directly in front of the rotary knob.3. When the green LED flashes, turn knob 90°.Unlock the megalock-l:1. Activate megalock-l  (push rotary knob)2 Hold TestKey directly in front of the rotary knob.3. megalock-l unlocks itself.NOTE:The TestKey is used to test the function of factory-new or non-configured mega-lock-l. Once the SetupKey has been used to configure the megalock-l for the sys-tem, the megalock-l can no longer be locked or unlocked using the TestKey!
OBID®megalock-lInstallationFEIG ELECTRONIC GmbH Page 7 of 14 megalock-l-manual.DOC4.2. Configuring the megalock-l with the "SetupKey"The SetupKey is used to configure the System-ID, the cabinet number, the operating mode and thegroup number in the megalock-l. Only than can the megalock-l be used in the system.An already configured megalock-l will no longer accept the SetupKey. To change the configurationof a megalock-l, the latter must first have been cleared using a valid ResetKey.CAUTION:Use only a SetupKey having the correct Group No. and System-ID.Operation:1. Set the parameters on megalock Admin or on the megalock Programmer and programthem into the SetupKey.Set the following data:- Next megalock-l number to be programmed (cabinet number)- Operating mode (free cabinet select / fixed cabinet assignment / multi-user mode)- Group No. to which the megalock-l is to be assigned.2. Go to the first megalock-l with the SetupKey, waken up the lock and configure it by pre-senting the SetupKey.The SetupKey must be held in front of the rotary knob until the megalock-l ac-knowledges this by causing the green LED to flash.3. Now the next megalock-l can be configured with a sequential cabinet number.Assigning the megalock number is done according to the same principle.Once the megalock-l has uploaded the num-ber, it increments the number on the Setup-Key by +1.Now the number for the next  megalock-l isstored on the SetupKey, and as many mega-locks as desired can be initialized with a se-quential number without having to first repro-gram the SetupKey.NOTE:If a gap in the sequential numbering of themegalock-ls is desired, such as at the endof a row of cabinets, the new cabinetnumber will have to be programmed intothe SetupKey.
OBID®megalock-lInstallationFEIG ELECTRONIC GmbH Page 8 of 14 megalock-l-manual.DOC4.3. Configuring for standard/daylight saving time "DSTKey"The DSTKey (Daylight Saving Time Key) is used to configure both switchover points for daylightsaving/standard time as well as the type of switchover in the megalock-l. The switchover rule forthe time change is programmed on the DSTKey.By default the time change rule of Central Europe (Begin: last Sunday in March; End: last Sunday inOctober) are programmed on DSTKey.For Changing the time change rule please ask you authorised megalock system partner.Operation:1. Activate megalock (push rotary knob)2. Present DSTKey. The megalock-s stores the changeover points and indicates this byflashing the green LEDNOTE:When starting up the megalock-l, be sure that the time change is configured using theDSTKey before the internal clock is set by the ClockSetKey. Otherwise the time of day maybe changed according to the specified changeover rule after the DSTKey is used.4.4.. Setting time of day and date "ClockSetKey"The ClockSetKey is used to set the real time clock integrated into the megalock-l to the current dateand time of day.NOTE:• The megalock-s only accepts the ClockSetKey if the internal realtime clock was acti-vated when configuring using the SetupKey• After replacing the battery in a megalock-l you must reset its realtime clock if it is active.• After the clock in the megalock-s has been set the megalock-s reaccepts the ClockSet-Key only after an additional 2 minutes have expired.
OBID®megalock-lInstallationFEIG ELECTRONIC GmbH Page 9 of 14 megalock-l-manual.DOCOperation:1. Program the time and date you want to set in the megalock-l on the ClockSetKey.2. When the programmed time of day is reached the megalock-l is "wakened“ and you pres-ent the ClockSetKey.A time 5 seconds later than the actual time of day is written back to the ClockSetKey.After the clock is set the new time of day programmed into the ClockSetKey, the mega-lock-l acknowledges by flashing the green LED.3. 5 seconds after setting the first megalock-l you can waken the next one and set the clockusing the ClockSetKey.This procedure can be repeated on any number of megalock-l as long as the 5 secondrhythm is kept for setting the clocks.If you cannot maintain the 5-second intervals, you must reprogram the ClockSetKey withthe actual time of day (as described in Step 1).
OBID®megalock-lInstallationFEIG ELECTRONIC GmbH Page 10 of 14 megalock-l-manual.DOC5. Resetting a megalock-l with the "ResetKey"Clearing a megalock-l may be necessary for example if a mistake was made in initialising (e.g.wrong cabinet number) or if a megalock-l needs to have a different configuration.NOTEThe ResetKey is only accepted by the megalock-l if it is unlocked!Operation:1. Activate megalock (push rotary knob)2. You have 8 seconds to hold the ResetKey in front of the rotary knob in the sensing zone ofthe megalock-l antenna. Once the parameters in the megalock-l have been cleared, the megalock-l acknowledgesthe process by causing the green LED to come on for a brief time followed by simultane-ous flashing of the green and red LED.3. Now the megalock-l can be reconfigured with a SetupKey(see: 4.2. Configuring the megalock-l with the "SetupKey").6. Replacing a megalock-lIf it becomes necessary to replace a megalock-l, the new megalock-l must first:1. be configured with the megalock number and other parameters using the SetupKey(see: 4.2. Configuring the megalock-l with the "SetupKey") and2. be actuated with a MasterKey to ensure that the new megalock-l accepts only MasterKeyshaving the currently valid MasterKey-Generation.
OBID®megalock-lInstallationFEIG ELECTRONIC GmbH Page 11 of 14 megalock-l-manual.DOC7. BatteryThe battery in the megalock-l is designed for at least 40 actuations daily within a period of 3 years.The time when the battery needs to be replaced will depend however on the self-discharging of thebattery and by climatic effects, especially cold temperatures.To summarize, the time to replace the battery depends on the following factors:1. the number of actuations,2. how long the battery has been installed, and3. the ambient temperature in which the megalock-l is operated.7.1. Battery replacementThe battery compartment integrated into the lock body is only accessible when the cabinet isopened, and can only be opened using a special screwdriver (Type: ID ML.SSD-A).• After opening the battery compartment, disconnect the discharged battery pack at the connectorand plug in the new battery pack.• Once the new battery pack has been installed, the megalock-l is ready for immediate use. Usethe ClockSetKey to set the internal real time clock after the battery was replaced or discon-nected.• The discharged battery pack must be properly disposed of according to prevailing envi-ronmental regulations!NOTE:• The discharged battery pack must be properly disposed of according to prevail-ing environmental regulations!• Use only batteries recommended by the manufacturer (Type: ID ML.BP-A). Theuse of non-approved batteries may cause malfunctions and result in damage tothe megalock-l.8. Service / MaintenanceThe mechanical parts of the  megalock-l are maintenance-free. Under no circumstancesuse mineral oil based lubricants or greases.Clean only using non-sticky, non-residue cleaners and disinfectants. Do not use harsh sol-vents, acids or lye for cleaning.NOTE:Cleaning with water-jet or steam jet could occur irreparable damage!
OBID®megalock-lInstallationFEIG ELECTRONIC GmbH Page 12 of 14 megalock-l-manual.DOCANNEX A Technical DataDimensions (W x H x D): approx. 110 x 119 x 84 mmWeight: approx. 350 g (incl. battery)Protection class IP 43Temperature range OperationStorage 0 °C to 60 °C-25 °C to 60 °CRelative humidity 10 % to 90 %(non-condensing)Battery Battery Pack (4 x Alkali Mignon-Cell (AA))Battery life expectancy 3 years assuming 40 operations daily(43.800 operations)Unlocking is possible for 6 weeks after reachingbattery alarm levelKey-Medium Transponder: OBID® ID DTx.BOperating frequency 125 kHzIndicators: 1 x LED red1 x LED greenReal Time Clock Date function from 01.01.2000 to 28.02.2100auto. Daylight saving time configurableOperation Modes free cabinet selectionfixed cabinet assignmentMulti-user modeMatrix modeReplacement parts / Tools:• Battery: Type: ID ML.BP-AArticle No.: 1152.001.00• Special screwdriver forreplacing battery: Type: ID ML.SSD-AArticle No.: 1153.001.00
OBID®megalock-lInstallationFEIG ELECTRONIC GmbH Page 13 of 14 megalock-l-manual.DOCANNEX B:Europe (CE)When properly used this radio equipment conforms to the basic requirements of Article 3 and theother relevant provisions of the R&TTE Directive 1999/5/EG of March 99.Equipment Classification according ETSI EN 300 330: Class 2USA (FCC)FCC ID: PJMMLL02This device complies with Part 15 of the FCC Rules. Operation is subject to the followingtwo conditions:(1) this device may not cause harmful interference, and(2) this device must accept any interference received, including interference that may causeundesired operation.Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
OBID®megalock-lInstallationFEIG ELECTRONIC GmbH Page 14 of 14 megalock-l-manual.DOCANHANG C: LED Blink-CodesLED Signal Description¥  1 x green(3 Sec) • Reset-Indicator (e.g. first activation after battery replacement)¥  1 x green • OK (Action was successfully completed)¥ 1 x red• Unknown megaKey Type• Action is only allowed on unlocked megalock-l e.g. ResetKey or Setup-Key.• The present free-megaKey has locked another megalock-l.• fixed-megaKey, multi-megaKey or ProgKey is not assigned to this mega-lock-l¥ 2 x red • megalock-l is in new or in reset state (e.g. after using ResetKey)• TestKey or SetupKey was used at an initialised megalock-l¥ 3 x red • megaKey is admitted at another megalock-l System.• megaKey or MasterKey are assigned to another group¥ 4 x red • Time limit or valid period exceeded• The megaKey is in moment not admitted at this megalock-l¥ 5 x red • The Key-Generation stored on the MasterKey or multi-megaKey or Sys-temKey is no longer valid for this megalock-l.¥ 6 x red• Handling error: megalock-l was not locked after a actuation with a validmegaKey• Mismatched type of megaKey and megalock operating mode (e.g. free-megaKey at megalock-l in fixed cabinet assignment or fixed-megaKey atmegalock-l in free cabinet selection, etc. ...).• ProgKey at a megalock-l which doesn't work in Matrix-Mode.• ClockSetKey or DSTKey at megalock-l with disabled real time clock.• Data on megaKey are incorrect or corrupt (e.g. megaKey was to short indetection range of the megalock-l)¥ ... ¥3 x red .. green .... • Battery alarmBefore megalock-l could used again the battery must be replaced.¥ & ¥3 x red & green • megalock-l is blocked after MasterKey I was used. Use MasterKey II tounblock megalock-l for further activation'sl & lconstantred&green• Internal Failure