Feig Electronic TSTFSAMK Wireless Safety System for industrial doors User Manual

Feig Electronic GmbH Wireless Safety System for industrial doors

Contents

User Manual

Download: Feig Electronic TSTFSAMK Wireless Safety System for industrial doors User Manual
Mirror Download [FCC.gov]Feig Electronic TSTFSAMK Wireless Safety System for industrial doors User Manual
Document ID2513709
Application IDA3NLgCvYnTCvyYjuRJM0+A==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize15.49kB (193653 bits)
Date Submitted2015-01-26 00:00:00
Date Available2015-01-26 00:00:00
Creation Date2012-10-02 08:35:29
Producing SoftwareAcrobat Distiller 6.0.1 (Windows)
Document Lastmod2012-10-02 12:54:13
Document TitleMicrosoft Word - FSAM-250_Inbetriebnahme_Eng-120814.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: heinze

Wireless Safety System for industrial
doors ‐ Mobile Unit
2. Installation of the mobile device:
6,5
TST FSAM 250 KBit
39
TST FSAM 250 KBit
TST FSAM 250 KBit
1. Pin connections:
Input 1 and 2 are normally open contacts with 8,2kΩ parallel resistor.
Input 3 is normally closed contact.
Remarks:
‐
Get note of the assembling position. The marked direction of transmission must show
to the stationary antenna.
‐
To fixing of the mobile device in the cover can be done with M4 plastic screws or it can
be sticked. But then you have to look about glue in antenna area. The plastic material
of the cover must not have transmission loss at 2.4GHz (e.g. ABS, PC or Teflon without
incorporation of conductive material for coloring).
‐
The battery can be installed in the gate profile. Take care that the battery is isolated
completely in order to prevent Isolation damages because of for doors typical
vibrations or that the battery cover will not be damaged by hard mechanical strikes.
‐
The electrical connection of the battery and the three Inputs must be isolated against
the gate profile.
Remark:
‐
Supply voltage of 3,6V with Thionyl Chloride Lithium battery e.g. XENO XL‐205F/19Ah.
‐
The battery is not part of the delivery .
FEIG ELECTRONIC GmbH ‹ Lange Str. 4 ‹ D‐35781 Weilburg, Germany ‹ Tel.: +49 (0) 6471 / 3109‐0 ‹ Fax: +49 (0) 6471 / 3109‐99 ‹ www.feig.de ‹ Email: info@feig.de
The content of the door controller manual and particularly the safety instructions must get
note. The rules for Disposal of electronic parts and of the battery, insert by customer, must
get note.
19,5
22
! ATTENTION
7,5
Installation‐ and Startup manual
3. Technical data:
5. Startup manual of the gate control:
Connection about plug‐in terminal RM 3.81 mm
Supply voltage:
3.6V (3.2V to 4.0V), typical 8.5mA active / 0.5mA
inactive.
Inputs:
Temperature range:
Three configure able inputs with following standard
configuration:
‐
inputs 1 and 2: safety edge input (N.O.) with 8.2kΩ
tested terminal resistor.
‐
Input 3: break away input (N.C.)
operating range –40°C to +70°C,
store range –40°C to +85°C
Operating frequency:
2400 to 2483.5MHz, 40 channels,
Rated output power 0dBm
Protection class:
IP65 for sealed‐in components on the board,
IP20 for terminals
Weight:
30g
lifetime of the battery:
typical two years by using XENO XL‐205F
Dimension (mm):
( L x B x H ) 68 x 38 x 7.6 +
antenna height 7mm + clamp
4. FCC Statements:
Notice: This device complies with Part 15 of the FCC Rules and with RSS‐210 of Industry Canada.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Notice: Changes or modifications made to this equipment not expressly approved by
FEIG ELECTRONIC may void the FCC authorization to operate this equipment.
Notice: This product has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures :
‐
Reorient or relocate the receiving antenna
‐
Increase the separation between the equipment and receiver
‐
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
‐
Consult the dealer or an experienced radio / TV technician for help
Extract from startup manual:
Configuration parameters for wireless safety edge:
‐ P.46B = 1 Activates the drive on delay of the door until the safety edge is
active and the evaluation works.
‐
P.46C = 1000ms Sets the maximum time in which the wireless edge has to be active for a
flawless drive start of the door.
‐
P.F00 = 1 Activates the wireless edge.
‐
P.F01 = 20ms
Sets the timeout for the wireless edge. If the edge is not answering within
the adjusted time the edge will recognized as released. (Edge 1 and 2).
‐
P.F04 = 0
0 = The mobile device will only wake up if necessary (Energy saving mode).
1 = The digital radio link is always active.
‐
‐
‐
‐
P.F05 = x Choice of radio channel group of mobile device (x = 1 … 10).
P.F06 = x Shows the used radio channel
P.F07 = xxx
Sets the address of the wanted mobile partner of the controller.
P.F08 = 3.0V
Sets the value for the battery voltage under which the error message F.856
will be shown.
5. Error messages:
‐
‐
‐
F.852
No RS485 data traffic between the controller and the stationary device in the TST
PDFSAS device for min. 1 second.
Possible Causes:
‐
Stationary device not connected or no supply voltage.
‐
Stationary radio device inside the encoder defective or disturbed.
‐
Interface cable defective (In this case you can also see F752 in combination).
F.856
Error of the digital radio link. No radio connection between both partners for more
than 10 seconds.
Possible Causes:
‐ No mobile device found
‐ Too low supply voltage of mobile device (Battery empty).
‐ Set address is wrong
‐ Antenna not connected or unfavorable mounted
‐ Strong disturbances on the used frequency range
F.857
This error is shown if the value of the voltage falls under the limit set with P.F08
(Battery monitoring).
FEIG ELECTRONIC GmbH ‹ Lange Str. 4 ‹ D‐35781 Weilburg, Germany ‹ Tel.: +49 (0) 6471 / 3109‐0 ‹ Fax: +49 (0) 6471 / 3109‐99 ‹ www.feig.de ‹ Email: info@feig.de

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Author                          : heinze
Create Date                     : 2012:10:02 08:35:29+02:00
Modify Date                     : 2012:10:02 12:54:13+02:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2012:10:02 12:54:13+02:00
Document ID                     : uuid:953dfd9a-e6f3-4a24-ad4c-bf545ae12d36
Instance ID                     : uuid:49dcd547-7765-4159-9ca0-70284d46c1fe
Format                          : application/pdf
Title                           : Microsoft Word - FSAM-250_Inbetriebnahme_Eng-120814.doc
Creator                         : heinze
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PJMTSTFSAMK

Navigation menu