Fibar Group FGBHFS101 Flood Sensor User Manual

Fibar Group S.A. Flood Sensor

User Manual

CONTENTS#1: Description and features  3#2: Powering the accessory  4#3: Pairing the  accessory  5#4: Physical installation  6#5: Reset  7#6: Functionalities  8#7: Congurable parameters  9#8: Specications  10#9: Regulations  11FIBARO FLOOD SENSORFGBHFS-101OPERATINGMANUAL ENv1.0
2 Important safety informationRead this manual before attempting to install the device! Failure to observe recommendations included in this manual may be dangerous or cause a violation of the law. The manufacturer, Fibar Group S.A. will not be held responsible for any loss or damage resulting from not following the instructions of operating manual.!HomeKit technologyApple HomeKit technology provides an easy, secure way to control HomeKit-enabled accessories using Siri on your iPhone, iPad, or iPod touch. After installing your FIBARO Flood Sensor, congure it from a compatible app with just a few simple steps. You can even create your own custom scenes to control your home settings. For example, you can create a scene to automatically turn o the lights, lock your doors, close the garage door, and set the thermostat to the desired temperature in just one step.
3DESCRIPTION AND FEATURESMain features of FIBARO Flood Sensor:•  compatible with Apple HomeKit technology•  Bluetooth® low energy technology for wireless communication•  detects ooding•  detects tampering using accelerometer or when the casing is opened•  easy installation - simply put on a surface prone to ooding•  may be installed anywhere - sensor can be extended using  an external probe•  battery powered•  indicates state using LED diode and buzzerFIBARO Flood Sensor is a HomeKit-enabled water sensor using Bluetooth® low energy technology. Along with detecting ooding, the accessory measures the ambient temperature. Tampering is detected whenever the accessory is moved or casing is opened.Built-in LED indicator and an acoustic alarm signal ooding and tampering. The LED can be also used to identify the accessory.The accessory is designed to be placed on the oor or mounted on a wall (in this case sensor should be extended using an external probe). The accessory is sink-proof, which means it drifts on the water surface and keeps on sending alarm signal in case of substantial inundation of water.#1: Description and featuresNOTESensor external probe is not included.iNOTEControlling this HomeKit-enabled ac-cessory requires an iPhone, iPad, or iPod touch with iOS 9.3 or later. Controlling this HomeKit-enabled ac- cessory away from home requires a third-generation Apple TV with Apple TV software 7.2.1 or later or a fourth generation AppleTV with tvOS 9.2 or later and an iPhone, iPad, or iPod touch with iOS 9.3 or lateri
4POWERING THE ACCESSORY#2: Powering the accessory1.  Turn the cover counter-clockwise and open it.2.  Remove the battery blocker.3.  The accessory will glow red – it is ready to be paired.4.  Close the cover and turn it clockwise.NOTEAfter completing installation it is rec-ommended to test sensor’s operation by placing the entire sen-sor or sensor probe onto a water surface.iNOTEIf the accessory blinks green after powering, it is already paired and has to be reset to pair again.i
5PAIRING THE  ACCESSORY#3: Pairing the  accessory1.  Open the Settings app on your iOS device.2.  Go to the Bluetooth® section, and turn the Bluetooth® on.3.  Place the accessory next to your iOS device.4.  Open a HomeKit app of your choosing on your iOS device.5.  Open pairing window in your HomeKit app to detect available  accessories.6.  Choose Flood Sensor you wish to pair.7.  You can identify it - Flood Sensor will triple blink blue 3 times.8.  Find HomeKit Setup Code on the last page of user manual includ-ed in the box that looks like this:9.  Start pairing with your HomeKit app.10. Point your iOS device’s camera at the Setup Code to scan it or en-ter the Setup Code manually.11. If entered Setup Code is valid, the device will complete the setup process.12. Follow instructions displayed in the application.NOTEUse Fibaro app to ful-ly utilize this product. Other HomeKit com-patible apps might not support all of its features.iXXX-XX-XXXNOTERemember to keep your HomeKit Setup Code in safe place. You  may need it in case of re-pairing.i
6PHYSICAL INSTALLATIONSENS 1SENS 2Extending Flood Sensor contacts with a wired probe:NOTEMounting screws shown in a diagram are not included. Choose a screw type depending on the building material it is being attached to.  iCAUTIONSensor’s contacts are dedicated to ood de-tection only. Do not connect external volt-age!!#4: Physical installationTo install the Flood Sensor simply place it sensor on a surface prone to ooding. Three electrodes underneath the device should evenly touch the sur-face.NOTESensor external probe is not included.iIf you want the accessory to be mounted on a wall or in a distance from ooding source, sensor should be extended using an external probe.NOTEBefore completing the installation it is recommended to test sensor’s operation by placing the entire sen-sor or sensor probe onto water surface.i
7RESETResetting the Flood Sensor to factory defaults: Reset procedure allows to restore the accessory back to its factory settings including HomeKit pairing. We recommend performing re-setting procedure within range of your iOS device’s Bluetooth®.1.  Open the cover.2.  Press the button 3 times then press and hold the button.3.  Wait for the LED indicator to glow yellow.4.  Release the button.5.  Click the button to conrm.6.  After resetting the accessory will glow red - it is ready to be paired again.NOTEIf reset procedure was performed out-side  iOS device’s Bluetooth® range the accessory will not be removed from the HomeKit app and will not respond. In this case remove the de-vice manually from the app. i#5: ResetButton
8FUNCTIONALITIES#6: FunctionalitiesFlooding detection:The Flood Sensor alarms about ooding whenever water connects sensor’s probes and reports it to your iOS device. Until the ooding does not cease, the accessory constantly beeps and blinks red signaling the alarm.Tampering signalization is ignored during the alarm.Tamper detection:The Flood Sensor detects tampering when the accessory is moved  or casing is opened and reports it to your iOS device. Tampering is indicated with an alternate blinking in red, blue and white and one short beep.Temperature measuring:The Flood Sensor measures ambient temperature every 10 min-utes. If the measured temperature diers from previously reported  by at least 1°C (1.8°F), accessory reports it to your iOS device.Battery level measuring:The Flood Sensor measures battery level every 24 hours and reports it to your iOS device. Additionally, if battery level is below 15%, the accessory will report low level battery status to your iOS device.NOTEIf you are using Fibaro app you can adjust sensitivity for tamper detection using pa-rameters.i
9CONFIGURABLE PARAMETERS#7: Congurable parameters1. Tamper – sensor sensitivityThis parameter allows to set sensitivity of tamper detection.The higher the value of this parameter, the higher the sensitivity. If the installation surface is prone to vibrations, setting lower sensitiv-ity is recommended.Available settings: 0 – tamper disabled1 – low sensitivity2 – medium sensitivity3 – high sensitivityDefault setting:  2 (medium sensitivity)
10SPECIFICATIONSPower supply:  Battery type:  EU directives compliance:   Radio protocol:  Radio frequency:  Range:   Operating temperature:  Measured temperature range:  Temperature measuring accuracy:  Dimensions (diameter x height):3.0V DC battery  CR123A  R&TTE 1999/5/EC RoHS 2011/65/EU  Bluetooth® low energy  2.4 GHz  up to 50m (free range) (164 feet)  0-40°C (32-104°F)  0-40°C (32-104°F)   ±0.5°C (±0.9°F)   72 x 28 mm (2.8 x 1.1 inch)#8: Specications
11REGULATIONS#9: RegulationsThis device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions:1. This device may not cause harmful interference2. This device must accept any interference received, including inter-ference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to pro-vide reasonable protection against harmful interference in a residen-tial installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a par-ticular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:•  Reorient or relocate the receiving antenna.•  Increase the separation between the equipment and receiver.•  Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.•  Consult the dealer or an experienced radio/TV technician for help.NoteChanges and modications not expressly approved by the manufac-turer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission’s rules.Industry Canada (IC) Compliance NoticeThis device complies with Industry Canada license-exempt RSSs. Oper-ation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, in-cluding interference that may cause undesired operation of the device.Cet appareil est conforme aux normes d’exemption de licence RSS d’In-dustry Canada. Son fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas causer d’interférence et (2) cet appareil doit accepter toute interférence, notamment les interférences qui peuvent aecter son fonctionnement.Radio frequency (RF) exposure statementThis equipment should be installed and operated keeping the radiator at least 20 cm or more away from person’s body.Cet équipement doit être installé et utilisé en gardant une distance de 20 cm ou plus entre le dispositif rayonnant et le corps.
12REGULATIONSDGT Warning StatementArticle 12 Without permission, any company, rm or user shall not alter the fre-quency,  increase the power, or change the characteristics and func-tions of the original design of the certied lower power frequency elec-tric machinery. Article 14 The application of low power frequency electric machineries shall not aect the navigation safety nor interfere a legal communication, if an interference is found, the service will be suspended until improvement is made and the interference no longer exists. 第十二條經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。 第十四條低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。 前項合法通信,指依電信法規定作業之無線電通信。低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。Legal NoticesAll information, including, but not limited to, information regarding the features, functionality, and/or other product specication are subject to change without notice. Fibaro reserves all rights to revise or update its products, software, or documentation without any obligation to no-tify any individual or entity.FIBARO and Fibar Group logo are trademarks of Fibar Group S.A. The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Fibar Group S.A. is under license. Apple, iPhone, iPad, iPad Air, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. HomeKit is a trademark of Apple Inc.All other brands and product names referred to herein are trademarks of their respective holders.Use of the Works with Apple HomeKit logo means that an electronic accessory has been designed to connect specically to iPod, iPhone, or iPad, respectively, and has been certied by the developer to meet Ap-ple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards.Declaration of conformityHereby, Fibar Group S.A. declares that FIBARO Flood Sensor is in compliance with the essential requirements and oth-er relevant provisions of Directive 1999/5/EC.

Navigation menu