Fibar Group FGK10X Door/Window Sensor User Manual DoorWindowSensor FGK 101 107 ENG v21 v23 dallas

Fibar Group S.A. Door/Window Sensor DoorWindowSensor FGK 101 107 ENG v21 v23 dallas

User Manual

Download: Fibar Group FGK10X Door/Window Sensor User Manual DoorWindowSensor  FGK 101 107 ENG v21 v23 dallas
Mirror Download [FCC.gov]Fibar Group FGK10X Door/Window Sensor User Manual DoorWindowSensor  FGK 101 107 ENG v21 v23 dallas
Document ID2170705
Application IDjJDTJv5lzPDXJ1joGXuNgw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize127.57kB (1594603 bits)
Date Submitted2014-01-20 00:00:00
Date Available2014-07-19 00:00:00
Creation Date2013-02-06 14:19:35
Producing SoftwareAdobe PDF library 9.90
Document Lastmod2013-11-29 16:56:57
Document TitleDoorWindowSensor FGK-101-107 ENG v21-v23_dallas
Document CreatorAdobe Illustrator CS5

Fibaro is a bidirectional wireless system. This means the signal is
not only sent to the receivers, but also the receivers send feedback
confirming the reception of the signal. This also confirms the
condition of receivers, which allows us to check whether or not a
device has actually been switched on. The safety of transmission of
the Fibaro System is comparable with a wire-linked bus system.
Fibaro operates in the free band for data transmission. The
frequency depends on the radio regulations in each individual
country.
OPERATING MANUAL
DOOR / WINDOW SENSOR
FGK - 101 - 107 v2.1 - v2.3
The Fibaro Door / Window Sensor is a wireless, battery powered,
Z-Wave compatible reed sensor. Each time its two parts, i.e. the
sensor's body and a magnet separate, a radio signal is sent. In
addition the Fibaro Door / Window Sensor supports one DS18B20
temperature sensor and has one potential free input.
The Fibaro Door / Window Sensor is designed for use with scenes in
home automation systems, alarm and surveillance systems and
everywhere else where information related to opening / closing of
doors, windows, garage gates, etc. is needed.
Technical data:
Power supply
single ER14250 (1/2AA) 3,6V
battery
Inputs
single, potential-free
In accordance with EU
standards
EMC 2004/108/EC
R&TTE 199/5/WE
FCC ID
2AA9MFGK10X
Supported temperature
sensors
single, DS18B20
0 - 40 °C
Radio protocol
Z-Wave
Radio frequency
868,4 MHz EU;
908,4 MHz US;
921,4 MHz AU/NZ;
869,2 MHz RU;
Range
up to 30m indoors, depending on
building materials used and the
building structure
Dimensions (L x W x H)
Although the Z-Wave technology is fairly new, it has already been
accepted as an official standard, just like Wi-Fi. Numerous
manufacturers from various fields offer solutions based on Z-Wave
technology, compatible with one another. This makes the system fit
for the future and allows for further development. For more
information go to www.fibaro.com.
GND
• Controlled via. Fibaro System components or any other Z-Wave
compatible controller,
• Door/window opening detected through Sensor's body and a
magnet separation,
• Quick installation - easily mounted on doors, windows, garage
gates, roller blinds, using double sided adhesive tape or screws,
• Compatible with DS18B20 temperature sensors,
• When connecting DS18B20 use single wire lead, no longer than 30
meters.
• May be connected to a switch via potential-free IN input.
HINT
Connections should be made specifically
according to the diagrams presented in this
manual. Incorrect connections may be hazardous
or lead to device damage.
I General Information on the Fibaro System:
Fibaro is a system that does not require any additional conductors;
it is based on the Z-Wave technology. Fibaro offers a wide array of
advantages in comparison to other, similar systems. In general,
radio-based systems establish a direct connection between the
receiver and the transmitter. The radio signal is attenuated by every
obstacle along its path (in the household e.g. walls, furniture, etc).
In the worst case the radio system ceases to function. The
advantage of the Fibaro System is the fact that the devices act not
only as a signal receiver and transmitter, but also as a signal
repeater. If a direct radio link between the transmitter and the
receiver cannot be established, the connection will be carried out
with the use of other devices participating in communication.
TMP
NOTE!
Fibaro Door/Window Sensor has two TMP buttons
- inside and underside the casing.
During normal operation both TMP buttons must be
secure. Do not use the sensor with opened casing.
NOTE!
TMP button, located on the underside of the
device, has two functions:
1. sets a device into the learn mode (Include to /
Exclude from a Z-Wave network),
2. tamper button. After correct installation (fig. 5
and 6), removing the whole sensor from its location
or opening its casing may release the TMP button
and trigger an alarm. If the TMP is to serve as a
tamper button, association for II-nd association
group must be configured (optionally, use the
Parameter 13).
Diagram 1 - General
(TOP VIEW)
DS18B20
TP (VDQ) max 30m
TD (DQ)
GND
TMP
DS18B20
The DS18B20 temperature sensor may be installed
anywhere where very precise temperature readouts
are necessary. If adequately protected, the
DS18B20 sensor may be installed in humid
conditions, under water, sealed in concrete or placed
under the floor.
Diagram 2 - Connection to DS18B20 sensor
(TOP VIEW)
GND
TMP
IN
GLOSSARY OF TERMS:
• INCLUSION - the device sends out a Node Info frame, which
makes it possible to add it to the Fibaro System (Home Center 2),
NOTE!
Do not connect sensors other than DS18B20 to the
1-wire line (TP and TD terminals).
NOTE!
It is prohibited to connect the TP and TD lines to
devices not compatible with the 1-wire protocol.
2) Touch the Sensor's body with a magnet,
3) Insert the battery,
4) Remove the magnet from the Sensor's body,
5) Remove the battery
• ASSOCIATION - controlling other devices included in the Fibaro
System,
6) Re-install the battery,
III Fibaro Sensor Start-up
STEP 1
Install the device observing the Figure 4 for correct positioning of
the Sensor and the magnet. Close the Sensor's casing.
Diagram 3 - Example connection - momentary switch
1) Take off the Sensor's cover and remove battery. Make sure the
TMP button is intact.
• EXCLUSION - remove the device from the Fibaro System,
1.Installation of the Door/Window Sensor
BELL-PUSH
Diagram 6 - Incorrect sensor installation
• Multi Channel Association - controlling other multi-channel
devices included in the Fibaro System
The antenna should be placed above the battery.
Never cut, shorten or bend the antenna. Its length is
suited ideally to the band at which the system
functions.
Metal surfaces in close vicinity (e.g. metal switch
boxes, metal door trims) may impair the reception
capability!
To reset the Fibaro Door/Window Sensor please follow below
instructions:
ANTENNA ARRANGEMENT INSTRUCTIONS:
NOTE!
Every time any changes are made to the
configuration of TP and TD lines (1-wire), i.e. when
DS18B20 sensor is connected/disconnected, it is
necessary to execute the procedure of exclusion
and repeated inclusion of the sensor module to the
Z-Wave network. The system will enter into the
learning mode only after connected DS18B20
sensor has been detected (about 10 s).
There is one way to reset the Fibaro Door/Window Sensor. The
procedure cleans its EPROM memory, including the main controller
and Z-Wave network data.
(VIEW FROM BELOW)
The Fibaro Door/Window Sensor has a one,
potential-free IN input. IN input status may be
modified through the Sensor itself or by sending
GND signal to IN (diagram 3). If the Door/Window
Sensor will be used only as a binary sensor, do not
install the magnet.
USING DS18B20 TEMPERATURE SENSOR:
NOTE!
Door/Window Sensor is equipped with a built-in
LED. LED blinks each time Door/Window Sensor
changes its state. LED blinking slowly = correct
inclusion. LED blinking rapidly = inclusion error.
2. Resetting the Fibaro Door/Window Sensor
1 2 3
1 2 3
USING IN INPUT:
The Fibaro Door/Window Sensor's battery life is up
to 2 years, on default settings.
Current battery level is displayed in the Home
Center 2 configuration interface. If a battery icon
turns red, it means the battery needs replacement.
In order not to trigger an alarm when replacing the
battery, II-nd association group must be deleted
and the Sensor's configuration must be changed to
default, prior to the battery change.
Diagram 5 - Correct sensor installation
TMP - Tamper button. Detects removal, tampering etc. Used also
as a service button, to include/exclude the device to/from the
Z-Wave network,
IN - Potential-free input,
TP – (TEMP_POWER) - Power out for DS18B20 temperature
sensor,
TD – (TEMP_DATA) - Signal terminal for DS18B20 temperature
sensor,
GND – (GROUND) - Ground terminal.
NOTE!
To ensure the most accurate position detecting
always install the magnet in relation to the Sensor's
body, as shown in diagram 4.
BATTERY USE:
(BOTTOM VIEW )
EXPLANATION OF CONDUCTOR MARKINGS:
Diagram 4 - Correct positioning of the Sensor
and the magnet
MAGNETIC
SENSOR
II Sensor Installation:
STEP 5
The Fibaro Door/Window Sensor is added to the network by quickly
pressing the TMP button three times (the button is located on the
underside of the device, inside its casing).
STEP 6
Correct inclusion of the device to the network will be signalled by
the Home Center 2 (see: Home Center 2 controller operation
instructions).
IN
Fibaro establishes a dynamic network structure. From the moment
of start-up, the location data of respective devices of the Fibaro
System is updated automatically, in real time, by confirming their
condition in the working mesh network.
76 x 17 x 19 mm
Technical information:
TD (DQ)
max. 5 mm
3 2 1
Operating temperature
TP (VDQ)
(TOP VIEW)
Each Fibaro network has its own unique network identification
number (home ID), which is why two or more independent systems
may be installed in a single building without any interference.
1.Connect Fibaro Door/Window Sensor according to the
appropriate diagram (if necessary)
2. Place battery inside the Sensor's casing,
3. Include into the Z-Wave network.
4. Install Fibaro Door/Window Sensor observing diagram 4,
STEP 4
Set the Home Center 2 controller to the inclusion or exclusion mode
(see: Home Center 2 controller instructions).
TMP
GND
TD (DQ)
TP (VDQ)
USA
7) Reset will be confirmed by double LED blink.
NOTE!
Resetting the device memory doesn't remove it
from the Z-Wave network's main controller
memory. To be able to re-include the device into the
Z-Wave network please exclude it first. Exclusion
may be performed either before or after the reset
procedure.
[Inclusion/Exclusion] of the Fibaro Door/Window Sensor [to/from]
the Z-Wave network.
3. Controlling the Fibaro Door/Window Sensor with
the Home Center 2 Controller
STEP 2
The Fibaro module must be in range of the Home Center 2
controller, because the procedure of inclusion to the Fibaro System
requires direct communication with the controller.
The Door/Window Sensor is a multichannel device. This means
that it is equipped with an independent input circuit and a 1-wire bus
allowing it to be connected to a DS18B20 temperature sensor. As a
result, each device is represented by an independent icon in the
System.
STEP 3
Locate TMP button, which allows for proper inclusion of device.
i
NOTE!
Any new association order given while any
association commands are already being sent to
devices, cancels previous one.
Parameter no. 9
Deactivating transmission of the alarm cancelling frame or the
control frame deactivating the device (Basic). It allows for disabling
the function of deactivating the device and cancelling alarms for
devices associated with IN input.
NOTE!
Scene activation functionality may shorten the
battery life, even by 25%.
Default value: 0
V Configuration
Fig. 1 - Door / Window Sensor icon
in the Home Center controller
The Door / Window Sensor offers a wide range of advanced
settings. The parameters listed below are available in the
Fibaro configuration interface.
In order to configure the Fibaro Door / Window Sensor (using the
Home Center 2 controller) go to the device options by clicking on
the icon:
Available parameter settings:
0 – for association group no. 1 information is sent
1 – for association group no. 1 information is not sent.
Parameter value: 1 [byte].
NOTE!
The parameter cancels alarms only. Information on
alarm violation or activation commands for devices
from association groups are always sent.
VI Additional Functionality
Alarm Frame Support.
The Fibaro System allows you to set the device’s reaction to alarms
(reaction to SENSOR_ALARM_REPORT frame). The Fibaro
Door/Window Sensor sends alarm frames of different types,
depending on parameter's no. 5 settings. The user should declare
type of alarm frame for each connected sensor. For example, for a
smoke detector connected to IN input the user should declare the
type 1–ALARM SMOKE frame (value of 1 should be entered), to
ensure the remaining Z-Wave network devices recognize the
information on smoke detector alarm correctly.
Next, select the device options tab.
Parameter no. 12
Device parameters:
Parameter no. 1
Input IN alarm cancellation delay.
Additional delay after an alarm from input IN has ceased. The
parameter allows user to specify additional time, after which the
input IN alarm is cancelled once its violation has ceased.
Default value: 0
Available parameter settings: 0 – 65535 s
Fig. 2 - DS18B20 temperature sensor icon
in the Home Center controller
Sensor used without a DS18B20 sensor, or used with a switch
connected to IN input, will be represented by single icon. After the
DS18B20 temperature sensor has been connected, temperature
sensor icon will be displayed.
NOTE!
If a temperature sensor icon is not displayed
despite the fact the sensor itself has been
connected, or if the temperature readings are
incorrect, inspect the connections on the 1-wire
bus, in particular the connection between sensor
outputs and the line, and the total length of the bus
wire which should not exceed 30m.
IV Association
Association allows the Fibaro Door/Window Sensor to directly
control another device in the Z-wave network, e.g. Dimmer, Switch
(On-Off), Roller Shutter or trigger scenes (scene control is only
possible via the Home Center 2 controller).
NOTE!
Association allows for direct transmission of control
commands between devices and takes place without
the participation of the main controller. Owing to this
mechanism the Door/Window Sensor may
communicate with devices even if the main controller
is completely destroyed, e.g. in the event of a fire.
The Fibaro Door/Window Sensor supports three association
groups.
Group I is assigned to input IN1 (and the magnetic sensor).
Sending BASIC SET or ALARM command frames.
Group II is assigned to TMP button. Once the button is released,
ALARM GENERIC frame is sent to associated devices.
Group III reports on the condition of the device, only one device
may be assigned to the group (main controller, by default).
The Fibaro Door/Window Sensor allows for control over 5 regular
devices and 5 multichannel devices per group, out of which 1 field
is reserved for the network controller.
In order to add an association (with the use of the Home Center 2
controller) go to device options by clicking this icon:
Select the device options tab. Next specify which devices will be
associated, and to which association groups. Sending of
configuration commands to associated devices might take up to a
few hours, depending on previous devices settings and the number
of devices within the network.
Parameter value: 2 [byte]
Parameter no. 2
Status change signalled by LED.
Default setting: 1
Available parameter settings:
0 - LED turned Off,
1 - LED turned On.
Parameter value: 1 [byte].
Sensitivity to temperature changes. The maximum acceptable
difference between the last reported temperature and the current
temperature read from the sensor. If the temperatures differ by the
set value or more, a report with the current temperature value is
sent to the device assigned to association group no. 3.
Default value: 8 [0,5oC]
Available parameter settings: 0 – 255 [0oC to 16oC] [32oF –
60,8oF]
Type of IN input.
Default value: 0 – INPUT_NC (Normal Close)
Available parameter settings:
0 – INPUT_NC (Normal Close)
1 – INPUT_NO (Normal Open)
2 – INPUT_MONOSTABLE
3 – INPUT_BISTABLE
Parameter value: 1 [byte].
Parameter no. 5
Type of control frame transmitted for association group 1, activated
via IN input. The parameter allows you to specify the type of an
alarm frame or to force control frames transmission (BASIC_SET)
Default value: 255 – BASIC SET
Available parameter settings:
0 – ALARM GENERIC frame
1 – ALARM SMOKE frame
2 – ALARM CO frame
3 – ALARM CO2 frame
4 – ALARM HEAT frame
5 – ALARM WATER frame
255 – Control frame BASIC_SET
Parameter value: 1 [byte].
Parameter no. 7
Value of the parameter specifying the forced level of dimming/opening roller blinds when “switch on”/”open” commands are sent to
devices from association group no.1.
In case of alarm frames an alarm priority is specified.
Default value: 255
Possible parameter settings: (1 – 99) and 255
Value of 255 makes it possible to activate a device. In case of the
Dimmer module it means activating the device and setting it to the
previously stored condition, e.g. when Dimmer is set to 30%,
deactivated and then reactivated using 255 commend, it will be
automatically set to the previous condition i.e. 30%.
Parameter value: 1 [byte].
The Fibaro Door/Window Sensor may be operated using:
• Any System compatible controller (e.g. Home Center 2)
• Cellular phone (e.g. iPhone or phones from other manufacturers,
with the proper control application)
• PC, with the use of an Internet browser,
• Tablets (e.g. iPad)
• Using the TMP button, located inside the housing.
To set an appropriate parameter value use the following formula:
x = delta T x 16 - for Celsius
x = delta T x 80 / 9 - for Fahrenheit
x = parameter value
delta T – maximum acceptable temperature gradient in Celsius or
Fahrenheit
If the value is set to 0:
- if the wake-up interval is set to 255 seconds, temperature report
will be sent according to the interval,
- if the wake-up interval is set to over 255, temperature report will be
sent each ca. 4 minutes.
Parameter value: 1 [byte].
Parameter no. 3
VII Door / Window Sensor operation
Parameter no. 13
Sending an alarm or control frame (for IN input, depending on
parameter no.5 value), and TMP button alarm frame. The frame is
sent in “broadcast” mode, i.e. to all devices within range information sent in this mode is not repeated by the mesh network.
Default value: 0
Available parameter settings:
0 – IN and TMP Broadcast mode inactive,
1 – IN broadcast mode active, TMP broadcast mode inactive
2 – IN broadcast mode inactive, TMP broadcast mode active
3 – IN and TMP broadcast mode active
Parameter value: 1 [byte].
NOTE!
If the “broadcast” mode of information transmission
is activated for a given channel, then transmission of
information in “singlecast” mode, i.e. to devices
assigned to the association group, for this channel is
deactivated.
Parameter no. 14
Scene activation functionality.
Default value: 0
Available parameter settings:
0 - functionality deactivated
1 - functionality activated
The device offers the possibility of sending commands compatible
with Command class scene activation. Information is sent to
devices assigned to association group no. 3
Controllers such as the Home Center 2 are able to interpret such
commands and based on these commands activate scenes, to
which specific scene IDs have been assigned. The user may
expand the functionality of a button connected to IN input by
distinguishing the sequence of it being pushed. For example:
double click would trigger the “goodnight” scene and triple click
would trigger the “morning” scene. To fully use the possibilities
offered by the parameter no.14 it is recommended to use a
momentary or a toggle switch (parameter no.3).
Scene ID is determined in the following manner:
IN input:
Switch from “off” to “on” ID10
Switch from “on” to “off” ID11
Remaining IDs are recognized correctly if the value of parameter
no.3 was set to 2
Holding down ID12
Releasing ID13
Double click ID14
Triple click ID15
Parameter value: 1 [byte].
VIII Procedure to be followed in case of interference
The Device does not react to a programmed transmitter:
• Make sure the maximum range has not been exceeded and there
are no obstacles along the signal path containing metal surfaces,
e.g. metal cabinets, Ferro concrete ceiling, load bearing walls, etc.
• Make sure the device is not in the learning mode.
• Alternately repeat the programming process.
IX Guarantee
1. The Guarantee is provided by FIBAR GROUP Sp. z o.o.
(hereinafter "Manufacturer"), based in Poznan, ul. Lotnicza 1;
60-421 Poznan, entered in the register of the National Court
Register kept by the District Court in Poznań, VIII Economic
Department of the National Court Register, no. 370151, NIP
7811858097, REGON: 301595664.
2. The Manufacturer is responsible for equipment malfunction
resulting from physical defects (manufacturing or material) of the
Device for 12 months from the date of its purchasing.
3. During the Guarantee period, the Manufacturer shall remove any
defects, free of charge, by repairing or replacing (at the sole
discretion of the Manufacturer) any defective components of the
Device with new or regenerated components, that are free of
defects. When the repair impossible, the Manufacturer reserves the
right to replace the device with a new or regenerated one, which
shall be free of any defects and its condition shall not be worse than
the original device owned by the Customer.
4. In special cases, when the device cannot be replaced with the
device of the same type (e.g. the device is no longer available in the
commercial offer), the Manufacturer may replace it with a different
device having technical parameters similar to the faulty one. Such
activity shall be considered as fulfilling the obligations of the
Manufacturer. The Manufacturer shall not refund money paid for the
device.
5. The holder of a valid guarantee shall submit a guarantee claim
through the guarantee service. Remember: before you submit a
guarantee claim, contact our technical support using telephone or
e-mail. More than 50% of operational problems is resolved
remotely, saving time and money spent to initiating guarantee
procedure. If remote support is insufficient, the Customer shall fill
the guarantee claim form (using our website - www.fibargroup.com)
in order to obtain claim authorization.
When the guarantee claim form is submitted correctly, the
Customer shall receive the claim confirmation with an unique
number (Return Merchandise Authorization -RMA).
6. The claim may be also submitted by telephone. In this case, the
call is recorded and the Customer shall be informed about it by a
consultant before submitting the claim. Immediately after submitting
the claim, the consultant shall provide the Customer with the claim
number (RMA-number).
7. When the guarantee claim form is submitted correctly, a
representative of the Authorised Guarantee Service (hereinafter as
"AGS") shall contact the Customer.
8. Defects revealed within the guarantee period shall be removed
not later than 30 days from the date of delivering the Device to AGS.
The guarantee period shall be extended by the time in which the
Device was kept by AGS.
9. The faulty device shall be provided by the Customer with
complete standard equipment and documents proving its purchase.
10. Parts replaced under the guarantee are the property of the
Manufacturer. The guarantee for all parts replaced in the guarantee
process shall be equal to the guarantee period of the original
device. The guarantee period of the replaced part shall not be
extended.
11. Costs of delivering the faulty device shall be borne by the
Customer. For unjustified service calls, the Service may charge the
Customer with travel expenses and handling costs related to the
case.
FIBARGROUP
FIBARO
12. AGS shall not accept a complaint claim only when:
• the Device was misused or the manual was not observed,
• the Device was provided by the Customer incomplete, without
accessories or nameplate,
• it was determined that the fault was caused by other reasons than
a material or manufacturing defect of the Device
• the guarantee document is not valid there is no proof of purchase,
In case of any technical questions contact customer service centre
in your country.
13. The Manufacturer shall not be liable for damages to property
caused by defective device. The Manufacturer shall not be liable for
indirect, incidental, special, consequential or punitive damages, or
for any damages, including, inter alia, loss of profits, savings, data,
loss of benefits, claims by third parties and any property damage or
personal injuries arising from or related to the use of the Device.
14. The guarantee shall not cover:
• mechanical damages (cracks, fractures, cuts, abrasions, physical
deformations caused by impact, falling or dropping the device or
other object, improper use or not observing the operating manual);
• damages resulting from external causes, e.g.: flood, storm, fire,
lightning, natural disasters, earthquakes, war, civil disturbance,
force majeure, unforeseen accidents, theft, water damage, liquid
leakage, battery spill, weather conditions, sunlight, sand, moisture,
high or low temperature, air pollution;
• damages caused by malfunctioning software, attack of a
computer virus, or by failure to update the software as recommended by the Manufacturer;
• damages resulting from: surges in the power and/or telecommunication network, improper connection to the grid in a manner
inconsistent with the operating manual, or from connecting other
devices not recommended by the Manufacturer.
• damages caused by operating or storing the device in extremely
adverse conditions, i.e. high humidity, dust, too low (freezing) or too
high ambient temperature. Detailed permissible conditions for
operating the Device are defined in the operating manual;
• damages caused by using accessories not recommended by the
Manufacturer
• damages caused by faulty electrical installation of the Customer,
including the use of incorrect fuses;
• damages caused by Customer's failure to provide maintenance
and servicing activities defined in the operating manual;
• damages resulting from the use of spurious spare parts or
accessories improper for given model, repairing and introducing
alterations by unauthorized persons;
• defects caused by operating faulty Device or accessories.
15. The scope of the guarantee repairs shall not include periodic
maintenance and inspections, in particular cleaning, adjustments,
operational checks, correction of errors or parameter programming
and other activities that should be performed by the user (Buyer).
The guarantee shall not cover natural wear and tear of the Device
and its components listed in the operating manual and in technical
documentation as such elements have a defined operational life.
16. If a defect is not covered by the guarantee, the Manufacturer
reserves the right to remove such defect at its sole discretion,
repairing the damaged or destroyed parts or providing components
necessary for repair or replacement.
17. This guarantee shall not exclude, limit or suspend the Customer
rights when the provided product is inconsistent with the purchase
agreement.
This Device may be used with all devices
certified with Z-Wave certificate and should be
compatible with such devices produced by
other manufacturers.
Any device compatible with Z-Wave may be added
to Fibaro system.
FCC ID: 2AA9MFGK10X
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO
OR TV INTERFERENCE CAUSED BY UNAUTHORIZED
MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS
COULD VOID THE USER’S AUTHORITY TO OPERATE THE
EQUIPMENT.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference, and
2.This device must accept any interference received, including
interference that may cause undesired operation. This equipment
has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
www.fibargroup.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.0-c060 61.134777, 2010/02/12-17:32:00
Format                          : application/pdf
Title                           : DoorWindowSensor  FGK-101-107 ENG v21-v23_dallas
Metadata Date                   : 2013:11:29 16:56:57+01:00
Modify Date                     : 2013:11:29 16:56:57+01:00
Create Date                     : 2013:02:06 14:19:35+01:00
Creator Tool                    : Adobe Illustrator CS5
Thumbnail Width                 : 184
Thumbnail Height                : 256
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 23339 bytes, use -b option to extract)
Instance ID                     : uuid:12c3c1b1-9b3b-3946-947e-de2f4c880e37
Document ID                     : xmp.did:0480117407206811871FB45993446AE2
Original Document ID            : uuid:5D20892493BFDB11914A8590D31508C8
Rendition Class                 : proof:pdf
Derived From Instance ID        : uuid:5b5c88fb-19a0-0145-8930-7904249dd90d
Derived From Document ID        : xmp.did:F77F11740720681188C6A584B0A29F1E
Derived From Original Document ID: uuid:5D20892493BFDB11914A8590D31508C8
Derived From Rendition Class    : proof:pdf
History Action                  : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:FB7F117407206811822AAD98C13933C3, xmp.iid:FD7F117407206811822AAD98C13933C3, xmp.iid:FE7F117407206811822AAD98C13933C3, xmp.iid:47517C4897206811822AAD98C13933C3, xmp.iid:F97F1174072068118083D98D789BBA2A, xmp.iid:EF480E79F5206811822A9820AD76697B, xmp.iid:F0480E79F5206811822A9820AD76697B, xmp.iid:F77F117407206811822A904C6285BD82, xmp.iid:F77F1174072068118083B364EBDEDFED, xmp.iid:F77F11740720681180839DBE489E1253, xmp.iid:F77F11740720681188C6A584B0A29F1E, xmp.iid:0480117407206811871FB45993446AE2
History When                    : 2011:09:02 11:02:22+02:00, 2011:09:02 14:45:16+02:00, 2011:09:02 18:53:42+02:00, 2011:09:05 12:24:37+02:00, 2011:09:15 13:30:54+02:00, 2012:01:17 12:36:23+01:00, 2012:01:17 12:55:48+01:00, 2012:05:28 10:54:49+02:00, 2012:11:13 16:27:59+01:00, 2012:11:27 15:25:50+01:00, 2012:12:13 17:07:04+01:00, 2013:02:06 14:19:33+01:00
History Software Agent          : Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5
History Changed                 : /, /, /, /, /, /, /, /, /, /, /, /
Manifest Link Form              : EmbedByReference, EmbedByReference
Manifest Reference File Path    : /Users/sjanicki/Desktop/!PRACA/Opakowania/instrukcje/drzwi_eng.jpg, /Users/sjanicki/Desktop/!PRACA/Opakowania/instrukcje/drzwi_temp_eng.jpg
Startup Profile                 : Print
Has Visible Overprint           : False
Has Visible Transparency        : True
N Pages                         : 1
Max Page Size W                 : 352.999986
Max Page Size H                 : 249.999555
Max Page Size Unit              : Millimeters
Font Name                       : Arial-BoldMT, ArialMT, BellMTBold
Font Family                     : Arial, Arial, BellMTBold
Font Face                       : Bold, Regular
Font Type                       : Open Type, Open Type, Unknown
Font Version                    : Version 5.01.2x, Version 5.01.2x, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168
Font Composite                  : False, False, False
Font File Name                  : Arial Bold.ttf, Arial.ttf, MyriadPro-Regular.otf
Plate Names                     : Cyan, Magenta, Yellow, Black
Swatch Groups Group Name        : Brights
Swatch Groups Group Type        : 1
Swatch Groups Colorants Swatch Name: C=60 M=90 Y=0 K=0
Swatch Groups Colorants Mode    : CMYK
Swatch Groups Colorants Type    : PROCESS
Swatch Groups Colorants Cyan    : 60.000004
Swatch Groups Colorants Magenta : 90.000000
Swatch Groups Colorants Yellow  : 0.003099
Swatch Groups Colorants Black   : 0.003099
Producer                        : Adobe PDF library 9.90
Page Count                      : 2
Creator                         : Adobe Illustrator(R) 15.0
For                             : Marcin Lenartowski,
Bounding Box                    : 0 -1432 1015 0
Container Version               : 9
Creator Version                 : 15
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AA9MFGK10X

Navigation menu