Fine Offset Electronics WH41 Air Quality Sensor User Manual
Fine Offset Electronics Co., Ltd. Air Quality Sensor
User Manual
Instruction Manual Air Quality6HnVor Model: WH Instruction Manual Contents 1. Introduction...........................................................2 2. Get Started........................................................... 2 2.1 Parts List....................................................2 2.2 Air Quality Sensor Set Up........................3 2.3 Display Console Set Up...........................4 2.3.1 Display Console Layout........................7 3. Wireless Sensor Installation..............................8 4. Console Operation.............................................. 9 4.1 °C/°F...........................................................9 4.2 MAX............................................................9 5. Sensor Resynchronization.................................9 6. Best Practices for Wireless Communication. 9 7. Function.............................................................. 10 8. Appendix.............................................................11 9. Specifications.....................................................12 9.1 Wireless Specifications......................... 12 9.2 Measurement Specifications................12 9.3 Power Consumption.............................. 12 10. FCC Statement................................................13 11. Warranty Information...................................... 15 Instruction Manual 1. Introduction Thanks for your purchasing of the WH0290 Wireless Air Quality Monitor with Indoor Temperature and Humidity. To ensure the best product performance, please read this manual and retain it for future reference. 2. Get Started Note: Power up sequence must be performed in the order shown in this section (insert batteries in the Air Quality Monitor first, then Sensor(transmitter). Attention: Do not mix old and new batteries Do not mix Alkaline, Standard, Lithium or Rechargeable batteries Ensure batteries are installed correctly with regard to polarity +/- 2.1 Parts List One Air Quality Monitor (Receiver) One Air Quality Sensor(Wireless PM2.5 Sensor) One USB Cable One User Manual Two LSD( low self discharge) Ni-MH Rechargeable Batteries Instruction Manual 2.2 Air Quality Sensor Set Up 1. Remove the battery door on the base of the air quality sensor as shown in Figure 1 Figure 1 Instruction Manual Solar panel Battery Compartment Cover Red LED Indicator (RF transmission) Blue LED Indicator (charging status) USB Port Battery Compartment 2. Insert two AA battery. 3. After inserting the battery, the remote sensor LED indicator will light for 4 seconds, and then flash once per 60 seconds thereafter. Each time it flashes, the sensor is transmitting data. 4. Close the battery door. 5. Connect the USB cable to a standard USB power adapter and charge battery until blue LED is turned off, indicating batteries are fully charged. 6. When no sufficient solar radiation is possible, a fully charged set battery can last for about 20 days( about 500hours), and battery status monitor on display will reflect the battery power status. When battery is empty, please charge sensor again. 2.3 Display Console Set Up 1. Move the remote about 2 to 3m away from Instruction Manual 2. the display console (if the sensor is too close, it may not be received by the display console). Remove the battery door on the back of the display, as shown in Figure 2. Insert one AA (alkaline, lithium or rechargeable) battery in the back of the display console. Figure 2 1. Integrated Hanging Hole 2. Tabletop Stand 3. °C/°F Button 4. MAX Button 5. Battery Compartment 6. Battery Compartment Cover Instruction Manual All of the LCD segments will light up for a few seconds to verify all segments are operating properly. Full Display Replace the battery door, and fold out the desk stand and place the console in the upright position. The console will instantly display indoor temperature and humidity. The PM 2.5 value will update on the display within a few minutes. While in the search mode, the reception search icon flash. If the remote does not update, please contact our Customer Service for support. 3. 2.3.1 Display Console Layout Instruction Manual Figure 3 1. 2. 3. 4. 5. 6. 7. 8. Current PM 2.5 value Air Quality Level 1h MAX PM 2.5 value Indoor Temperature Indoor Humidity 24h MAX PM 2.5 value History MAX PM 2.5 value Outdoor Reception Icon Instruction Manual 3. Wireless Sensor Installation Outdoor Installation Use four screws to fix the base of the outdoor sensor on a flat surface. Instruction Manual 4. Console Operation Note: The console has two buttons for easy operation:【°C/°F】button (on the left), and【MAX】 button (on the right). 4.1 °C/°F Short press 【 °C/°F 】 button to select the temperature unit: °C/°F 4.2 MAX Press the MAX button for 5s to clear the history max and 24h max PM 2.5 value. 5. Sensor Resynchronization When the remote sensor lost reception, holding the °C/°F and MAX button for 5s, will register new outdoor for 12 minutes. While in the search mode, the reception search icon flash. 6. Best Practices for Wireless Communication Note: To insure proper communication, place the remote sensor on a flat surface. Do not lean or upside down it to avoid any damage. Instruction Manual Keep the console several feet away from computer monitors and TVs. 7. Function 1) 2) 3) 4) 5) Indoor temperature and humidity Every 60 second the unit will measure indoor temperature and humidity. PM 2.5 current and max value for 1h/24h/history. Every 60 second the unit will receive wireless PM 2.5 sensor. Wireless Signal Strength Indicator During the synchronization, it will reduce one signal segment if it have not received the signal once from the transmitter. It will increase one signal segment if it has received the signal once. Lost the signal once Received the signal once 10 Instruction Manual 8. Appendix About the Air Quality Levels AQI Air Pollution Level 0 - 50 Good 51 -100 101-150 151-200 Moderate Mild Unhealthy 201-300 Severe 300+ Hazardous Health Implications Air quality is considered satisfactory, and air pollution poses little or no risk Air quality is acceptable; however, for some pollutants there may be a moderate health concern for a very small number of people who are unusually sensitive to air pollution. Members of sensitive groups may experience health effects. The general public is not likely to be affected. Everyone may begin to experience health effects; members of sensitive groups may experience more serious health effects Health warnings of emergency conditions. The entire population is more likely to be affected. Health alert: everyone may experience more serious health effects 11 Cautionary Statement (for PM2.5) None Active children and adults, and people with respiratory disease, such as asthma, should limit prolonged outdoor exertion. Active children and adults, and people with respiratory disease, such as asthma, should limit prolonged outdoor exertion. Active children and adults, and people with respiratory disease, such as asthma, should avoid prolonged outdoor exertion; everyone else, especially children, should limit prolonged outdoor exertion Active children and adults, and people with respiratory disease, such as asthma, should avoid all outdoor exertion; everyone else, especially children, should limit outdoor exertion. Everyone should avoid all outdoor exertion Instruction Manual 9. Specifications 9.1 Wireless Specifications Line of sight wireless transmission (in open air): 300feet(100meters) Frequency: 433.92 MHz Update Rate: 60 seconds 9.2 Measurement Specifications The following table provides specifications for the measured parameters. Measurement Indoor temperature Indoor Humidity Range 14 to 140 °F Accuracy ± 1 °F Resolution 0.1 °F 1 to 99 % 1% PM 2.5 0~999ug/m3 Accuracy +/- 3% RH (@25°C. , 30%RH to 80%RH). Accuracy +/- 5% RH (@25°C. , 1%RH to29%RH;80%RH to 99%RH) ±5ug/m3 or ±10% 1ug/m3 9.3 Power Consumption Base station (display console) : 1 x AA Alkaline or Lithium batteries (not included) Remote sensor : 2 x AA 1.2V LSD type NI-MH batteries (included) Solar panel for backup power Note: 1. Battery type for charging: 2 x AA 1.2V 12 Instruction Manual NI-MH batteries(battery life: 3 weeks) 2. It's recommended to recharge the outdoor sensor every two week. 3. Charge time: 3h (The blue LED indicator will light when in charge and be off when full charged) 4.Charge Method: USB charge(USB Cable included) 10. FCC Statement Statement according to FCC part 15.19: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Statement according to FCC part 15.21: Any changes or Modifications not expressly approved by this company could void the user's authority to operate the equipment. Statement according to FCC part 15.105: NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 13 Instruction Manual interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. 14 Instruction Manual 11. Warranty Information We disclaim any responsibility for any technical error or printing error, or their consequences. All trademarks and patents are recognized. We provide a 1-year limited warranty on this product against manufacturing defects in materials and workmanship. This limited warranty begins on the original date of purchase, is valid only on products purchased and only to the original purchaser of this product. To receive warranty service, the purchaser must contact us for problem determination and service procedures. This warranty covers only actual defects within the product itself, and does not cover the cost of installation or removal from a fixed installation, normal set-up or adjustments, claims based on misrepresentation by the seller or performance variations resulting from installation-related circumstances. 15
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Author : MX Comments : Company : Create Date : 2018:01:25 14:23:27+06:00 Modify Date : 2018:04:02 11:25:08+08:00 Source Modified : D:20180125142327+06'23' Subject : Trapped : false XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Format : application/pdf Creator : MX Description : Title : Creator Tool : WPS Office Metadata Date : 2018:04:02 11:25:08+08:00 Keywords : Producer : Document ID : uuid:b782cca9-d4e2-4c3a-877e-c5aba7094d3b Instance ID : uuid:1322afc1-0897-4da6-8f3a-d5f008b67dd5 Page Count : 16EXIF Metadata provided by EXIF.tools