Fingerchip Intelligent Technology E202 Smart lock User Manual 1
Shenzhen Fingerchip Intelligent Technology Co., Ltd. Smart lock 1
User Manual
Information & Safety Warnings Note: Please prepare a Phillips screw driver and 4 AA batteries before Smart Lock User Manual 2. Installation Overview 10 9 8 7 6 11 12 13 14 4 3 2 1 installation. 1. Keep your fingers clean before using this product. 2. In original settings, it can be unlocked with any fingerprint, any card, or password `1234567890` and `#`. 3. If the power is insufficient, there will be an alarm prompt, please replace with 4 new batteries in time. 4. Please don`t use corrodent material to clean the surface. 5. When the password/fingerprint/card/APP can not unlock the door, please use the key to unlock the door. Please keep the emergency key with you or put it in outdoor safe place. 6. The lock is suitable for 40-100mm thick doors. Features 1. The total capacity of system is 300, and Fingerprint capacity is up to 100, and the first three are administrator. 2. Touching button, durable. 3. Support 6-8 password and 20 virtual password. 15 16 3 . Confirm The Direction of The Door This smart lock is suitable for Left Out/Left In/Right Out/Right In) 4 kinds of door opening directions. Left Hand Door Indoor 4. Support low power warning. Name Outdoor Indoor Fingerprint Sensor semiconductor 500 Identify Time 0.3S Unlock Way Fingerprint, Card, Password, Key and APP System Capacity 300 Right Hand Door Indoor Right In Left In Parameter DPI 17 18 19 20 1.Front Panel 2.Connection Column 3.Square Steel 4.Lock Body 5.Connection Line 6.Back Panel 7.`SET` Button 8.Connectiion Column Screws 9.Battery Cover 10.Battery Cover Screw 11.Back Handle 12.Connectiion Column Screws 13.Reverse Lock Knob 14.Back Locking Paddle 15.Latch-bolt 16.Lock Body Screws 17.Connectiion Column 18.Key Hole 19.Emergency Power Port 20.Front Handle Outdoor Indoor Right Out Left Out Outdoor Outdoor 4. Open Hole Please refer to the opening hole drawing, and drill right holes on the door. Supply Voltage 6V Low Voltage Warning 4.8V 5. Install Lock Body Standby Current <=50uA 5.1. Choose the installation direction of the latch-bolt of the lock body by the door opening directions. Installation Left In/ Right Out 1. Installation Instructions Left Out/ Right In a. It is recommended to look for professionals to install, watch the video carefully before installing. b. Please note that the connection line can’t be pressed or folded during installation. c. Before the installation, the lock must be selected correctly according E202 Please read this manual carefully before use Customer Service: (+86)+400 900 5952 http://en.fingercrystal.com to the door opening direction, because the handle can't be adjusted. d. While installing, the door must be in half open state until the commissioning is completed. e. After the installation is completed, when the fingerprint, card, password(1234567890) and #, APP, key unlock, test whether the front handle and back handle unlock/lock normally or not. f . If it does not work properly, please check if there is improper installation or the power cord is loose. 5.2. Change the direction of lock body latch-bolt a. Push the reversing block to the other side. b. Push the latch-bolt into the lock and turn 180 degrees. Reversing block Square Steel Hole c. Put back the reversing block, and the latch-bolt will pop up automatically. Lock Body(5052) 5.3. Put the lock body into the door frame and tighten 2 fixing screws. Using The Lock 6. Choose The Parts Add The Administrator Choose suitable parts according to the following table. Connection Column Connection Column Length Screw Length Door thickness Square Steel Length 1.57-2.16 Inch 3.15 Inch 1.38 Inch 2.17-2.36 Inch 3.15 Inch 1.77 or 2.17 Inch 1.18 and 1.97 Inch 2.76-3.15 Inch 3.94 Inch 1.77 or 2.17 Inch 1.97 and 2.76 Inch 3.55-3.94 Inch 4.72 Inch 1.77 or 2.17 Inch 2.76 and 3.54 Inch >3.94 Inch 5.51 Inch 1.77 or 2.17 Inch 3.54 and 4.33 Inch 1.18 and 1.97 Inch 1. Remove the battery cover, short press `Set`(back panel) or long press `*`, then the voice prompts: `Please add administrator`. 2. Add admin`s fingerprint(the same fingerprint,3 times), card, or password (6-8 numbers) and `#`(the same password, 2 times). 3. The voice prompts: `add successfully`. 4. Then you can continue to add. Notes: 1. The first three are administrator. 2. `*`: Back, Sign out button, `#`: confirm button. Add The User 1. Remove the battery cover, short press `Set`(back panel) or long press `*`, then the voice prompts: `Please verify the administrator`. 2. Verify the administrator. 3. Add user`s fingerprint(the same fingerprint,3 times), card, or password (6-8 numbers) and `#`(the same password, 2 times). 4. The voice prompts: `Add successfully`. 5. Then you can continue to add. 7. Install The Lock 7.1. Install 2 connection columns on the front panel. Delete The User 7.2. Install the front panel. 1. Remove the battery cover, short press `Set`(back panel) or long press `*`, then the voice prompts: `Please verify the administrator`. 2. Verify the administrator. 3. Short press Set(back panel) or long press `*` again. 4. Press `1` to remove all user fingerprints, press `2` to remove all user passwords, press `3` to remove all user cards, press `4` to remove all users. 5. The voice prompts:`successful`. a. Insert the suitable square steel into the Door lock body. b. Pass the connection line through the door hole. hole of the front panel and fix the front panel Reset The Lock on the door, then press the other end of the 1. Remove the battery cover, long press `Set` for 3 seconds. 2. The system restore to the factory default settings. square steel. Notes: 1. After the reset, all the information are removed (including administrator). 2. Administrator password will return to its default `1234567890`. 3. Please add a new administrator immediately. 7.3. Install the back panel. a. Press the front panel, and connect the interface of the back panel, then Insert the excess line into the door hole. b. Insert back locking p addle into the lock body, and you can cut off one or two sections of back locking paddle according to the thickness of the door. Connection Column Screws Hole Door Square Steel Hole c. Align the square steel with the square steel hole of the back panel, and compress Back Locking Paddle the back panel. APP Installation 1. Search `tuyaaoni` in APP store, download and install APP. 2. Registration and login with the mobile phone number. 3. Please refer to the operation prompt to complete the network configuration. Add Network 1. Short press `3`+`#`, Verify the administrator. 2. Network configuration mode: press # to change. a. Normal mode: the LED of `8` fast flash, please add network in APP. b. Compatibility mode: the LED of `8` slow flash, please add network in the Compatibility mode of APP. 3. Add successfully: The voice prompts `add successfully`. 4. Add failure: LED light show `X` and the voice prompts `add failure`. d. Lock 2 connection column screws to fix the back panel. e. Install 4 AA batteries and the battery cover, then lock the battery cover screw. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Note: The administrator can`t be removed by doing this. c. Align the square steel with the square steel connection line with the corresponding FCC STATEMENT : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Self-locking Warranty Card 1. Please fill out the warranty card and keep it well. 2. The warranty period of this product is 18 months. 3. The following belongs to the scope of non warranty: a. The warranty has expired. b. Damage occurred during or in relation to non-routine and/or unauthorized disassembly. c. Failure to provide a valid proof of purchase when requesting service or repair. d. Damage occurred as a result of natural disaster.(including earthquake, fire, flood etc.) e. Damage occurred due to unexpected factors or man-made reasons. (including mis-operation, improper insert or pulling, hauling, bumping, improper voltage input and others) 4. We will charge for the repairing if it is out of warranty. 5. When the product breaks down, ask your local dealer for repair and write out specific information below. Product Name Product Model Product Price Date of Purchase User Name User Phone User Address Seller Name Seller Phone Seller Address If the password is entered wrong for 5 times continuously, the system will be locked for 180 seconds, and the fingerprint or card unlock can remove self-locking. Order Number Low Power Warning Maintenance records(Filled in by the maintenance agency) 8. Install Buckle Plate A nd Buckle Box Tapping Screw Door Frame When the battery power is lower than 4.8V, the lock will prompt `The battery is use up, please replace it`, please replace with 4 new batteries in time. Buckle Plate Virtual Password Enter virtual password before or after the real password, it can be unlocked. Buckle Box Date Fault Result Signature
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Profile CMM Type : Linotronic Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : Hewlett-Packard Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : Hewlett-Packard Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Page Count : 2 Create Date : 2018:08:29 17:02:19+08:00 Modify Date : 2018:08:29 17:02:19+08:00 Producer : Corel PDF Engine Version 16.1.0.843 Author : Administrator Creator : CorelDRAW X6 Title : 未命名 -1EXIF Metadata provided by EXIF.tools