Fiplex Communications DHS37-R SINGLE CHANNEL AMPLIFIER User Manual TETRA User s Manual

Fiplex Communications Inc SINGLE CHANNEL AMPLIFIER TETRA User s Manual

User Manual

Download: Fiplex Communications DHS37-R SINGLE CHANNEL AMPLIFIER User Manual TETRA User s Manual
Mirror Download [FCC.gov]Fiplex Communications DHS37-R SINGLE CHANNEL AMPLIFIER User Manual TETRA User s Manual
Document ID3643818
Application IDZP9YNgbeGAb/2xdZvqGFxw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize315.25kB (3940687 bits)
Date Submitted2017-11-17 00:00:00
Date Available2017-11-17 00:00:00
Creation Date2017-10-20 17:24:31
Producing SoftwareMicrosoft® Word 2013
Document Lastmod2017-10-20 17:24:31
Document TitleTETRA User's Manual
Document CreatorMicrosoft® Word 2013
Document Author: gponcedeleon

English
DHSxx – PS800 Digital Fiber DAS
User & Installation Manual
Document History
Description
Revision
Date Issued
Original version
1.0
July 3rd, 2014
General Review
2.0
March 2nd, 2016
General Update
3.0
7 June, 2017
UM-0909
II
About this manual
This manual describes installation, commissioning, operation and maintenance of the Fiplex PS800 Digital Fiber DAS, and
Fiplex Control Software (FCS). The hardware included in this manual corresponds to the Digital Master Unit (DM) DHS00M and Digital Remote Unit (DR) DHS37-R.
The first part of the manual describes the Digital Fiber DAS hardware and the second part describes the software.
Hardware and software mentioned in this manual are subjected to continuous development and improvement. Consequently,
there may be minor discrepancies between the information in the manual and the performance and design of the hardware
and software. Specifications, dimensions and other statements mentioned in this manual are subject to change without notice.
This manual or parts of it may not be reproduced without the written permission of Fiplex Communications Inc.
Infringements will be prosecuted. All rights reserved.
Copyright © Fiplex Communications Inc, Miami, 2017.
UM-0909
III
Abbreviations
AGC
AMPS
ARFCN
BCCH
BS
CDMA
DC
DCS
DL
DPLX
EEPROM
EGSM
ETACS
ETSI
FCS
GSM
HW
LED
LNA
MS
OMS
OL
PA
PCN
PCS
PS
RF
RSSI
SW
TDMA
UL
WEEE
UM-0909
Automatic Gain Control
Advanced Mobile Phone Service
Absolute Radio Frequency Channel Number
Broadcast Control Channel (GSM broadcast channel time slot)
Base Station, BS antenna = towards the base station
Code Division Multiple Access
Direct Current
Digital Communication System (same as PCN)
Downlink signal direction (from base station via repeater to mobile station)
Duplex filter
Electrical Erasable Programmable Read Only Memory
Extended Global System for Mobile communication
Extended Total Access Communication System
European Telecommunications Standard Institute
Fiplex Control Software
Global System for Mobile communication
Hardware
Light Emitting Diode
Low Noise Amplifier, uplink and downlink
Mobile Station, MS antenna = towards the mobile station
Operation and Maintenance System
Overload
Power Amplifier
Personal Communication Network (same as DCS)
Personal Communication System
Power Supply
Radio Frequency
Received Signal Strength Indication
Software
Time Division Multiple Access
Uplink signal direction (from mobile station via repeater to base station)
Waste of Electric and Electronic Equipment
IV
Part 1 HARDWARE
1.
Safety
Caution!
This manual lists a set of rules and warnings to be accomplished when installing, commissioning and
operating a Fiber DAS Master Optical Unit from FIPLEX. Any omission may result in damage and/or
injuries to the System and/or the System Operators or Users.
If an instruction is not clear or you consider is missing, please contact immediately to Fiplex. See
www.fiplex.com for contact information.
Dangerous Voltage Warning
Any personnel involved in installation, operation or service of this equipment must understand and obey
the following:
The power supply unit supplied from the mains contains dangerous voltage level,
which can cause electric shock. Switch the mains off prior to any work in such
equipment. Any local regulations are to be followed when servicing MOUs.
Authorized service personnel only are allowed to service repeaters while the main
is switched on.
R&TTE Compliance Statement
This equipment complies with the appropriate essential requirements of Article 3 of the R&TTE Directive
1999/5/EC.
Station Ground
BTS chassis, MOU, feeders, donor antenna, service antenna/s and auxiliary equipment (splitters, tabs, .etc)
are required to be bonded to protective grounding using the bonding stud or screw provided with each unit.
Electrostatic Discharge
Static electricity means no risk of personal injury but it can severely damage essential parts of the
equipment, if not handled carefully.
Parts on the printed circuit boards as well as other parts in the unit are sensitive to electrostatic discharge.
Never touch printed circuit boards or uninsulated conductor surfaces unless absolutely
necessary.
If you must handle printed circuit boards or uninsulated conductor surfaces, use ESD protective
equipment. Never let your clothes touch printed circuit boards or uninsulated conductor surfaces.
Disposal of Electric and Electronic Waste
Pursuant to the WEEE EU Directive electronic and electrical waste must not be disposed of with unsorted
waste. Please contact your local recycling authority for disposal of this product.
Class 1 Laser.
MOU1x Series is equipped with Class 1 Laser according to EN 60825-1.
Cautions:
Never look directly into the laser beam.
Never point a laser beam at a person.
Do not aim the laser at reflective surfaces.
User Manual– Digital DAS
CLASS 1
LASER
PRODUCT
Fibers carry transmission power in both direction due to the use of WDM
Never view a laser pointer using an optical instrument, such as binocular or a
microscope.
Never handle non-dark fibers.
RF Exposure.
As a part of a Telecommunications System, MOU1x is not intended to radiate signals and meets EMC
directives, but within the System may have cables and antennas that are potential sources of radiating.
Contact the System Design to verify the compliance of the Exposure to Non-Ionising Radiation.
UM-0909
FCC Compliance
This is a 90.219 Class B device.
WARNING: This is a 90.219 Class B device. This is NOT a CONSUMER device. It is designed
for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC
LICENSE or express consent of an FCC Licensee to operate this device. You MUST register
Class B signal boosters (as defined in 47 CFR 90.219) online at www.fcc.gov/signalboosters/registration. Unauthorized use may result in significant forfeiture penalties, including
penalties in excess of $100,000 for each continuing violation. The installation procedure must
result in the signal booster complying with FCC requirements 90.219(d). In order to meet FCC
requirements 90.219(d), it may be necessary for the installer to reduce the UL and/or DL output
power for certain installations.
ATTENTION: This device complies with Part 15 of the FCC rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful interference and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
ATTENTION: FCC regulation mandate that the ERP of type B devices should not
exceed 5W. This device has a maximum programmable composite output power of
5W (+37dBm), therefore the gain of the DL antenna should be of 0dBi or less and
maintain a minimum separation of 45 cm from all persons, and the gain of the UL
antenna should be 13dBi or less and maintain a minimum separation of 45 cm from all
persons.
IC Compliance
As per RSS 131 Issue 2:




Nominal passband gain: 80dB max
Nominal bandwidth: 18MHz maximum for Canada market
Rated mean output power: Up to +37dBm maximum.
Input and Output impedances: 50 ohms
The Manufacturer's rated output power of this equipment is for single carrier operation. For
situations when multiple carrier signals are present, the rating would have to be reduced by 3.5
dB, especially where the output signal is re-radiated and can cause interference to adjacent band
users. This power reduction is to be by means of input power or gain reduction and not by an
attenuator at the output of the device.
RF Exposure Statement for ISED: “This device complies with Health Canada’s Safety Code. The
installer of this device should ensure that RF radiation is not emitted in excess of the Health
Canada’s requirement. Information can be obtained at http://www.hc-sc.gc.ca/ewhsemt/pubs/radiation/radio_guide-lignes_direct/index-eng.php”
UM-0909
The antenna/s used for this transmitter must be installed to provide a separation of at least 45 cm
in DL and 45 cm in UL from all persons and must not be collocated or operating in conjunction
with any other antenna or transmitter. Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to operate the equipment.
Selon RSS 131 Issue 2:
• Gain de bande passante nominal: 80dB max
• Bande passante nominale: 18MHz maximum pour le marché canadien
• Puissance nominale de sortie moyenne: Jusqu'à + 37dBm maximum.
• Impédances d'entrée et de sortie: 50 ohms
La puissance de sortie nominale du fabricant de cet équipement est pour le fonctionnement d'une
seule porteuse. Pour les situations où plusieurs signaux de porteuse sont présents, la cote devrait
être réduite de 3,5 dB, en particulier lorsque le signal de sortie est ré-irradié et peut causer des
interférences aux utilisateurs de bande adjacents. Cette réduction de puissance doit se faire au
moyen d'une puissance d'entrée ou d'une réduction de gain et non pas par un atténuateur à la
sortie du dispositif.
Déclaration d'exposition RF pour ISED: «Cet appareil est conforme au Code de sécurité de Santé
Canada. L'installateur de cet appareil doit s'assurer que les rayonnements RF ne sont pas émis
au-delà de l'exigence de Santé Canada. Vous pouvez obtenir de l'information à l'adresse
http://www.hc-sc.gc.ca/ewh-semt/pubs/radiation/radio_guide-lignes_direct/index-fra.php.
L'antenne utilisée pour cet émetteur doit être installée de manière à assurer une séparation d'au
moins 45 cm dans DL et 45 cm dans UL de toutes les personnes et ne doit pas être collocée ni
fonctionner avec une autre antenne ou émetteur. Les changements ou modifications non
expressément approuvés par la partie responsable de la conformité pourraient annuler
l'autorisation de l'utilisateur d'utiliser l'équipement.
UM-0909
2. Product Description.
The Fiplex PS800 Digital DAS has a modular structure that consists on two different modules, the Digital Master
Unit DHS00-M and the Digital Remote Unit DHS37-R. Each one of the different modules is enclosed in the same
or equivalent case, therefore, product description and installing instruction sections are valid for all of them.
The Fiplex Digital Master is a RF-to-Fiber and Fiber-to-RF conversion system. These conversions are done using
FPGA based Digital Signal Processing. It provides a connection to the Base Station and it centralises all the
connectivity of the DAS. It also provides the possibility to connect up to six Digital Remote Units.
The Digital Remote Unit, also is a RF-to-Fiber and Fiber-to-RF conversion system. These conversions are also
made using FPGA based Digital Signal Processing. It provides amplification to the RF signals needed to provide
signal amplification into the target area.
The Master and Remote Units is where the RF interfaces are located, the Master Unit has the “To Base” interface,
and the Remote Unit has the “To Mobile” interface. The Master and Remote Units have internal duplexers
therefore, the RF interface will have one RF port in each unit, the Master will have a “To Base” RF Port, and the
Remote Units will have “To Mobile” RF Ports.
The advantages of using digital signal transportation over fiber are to avoid the addition of the fiber analog noise
when it is used to transport analog signals. Along with this, the UL squelch of the Digital Remote Unit works not
only per channel but also per time slot, this makes the Fiplex Digital DAS solution unique by its outstanding
management of the UL noise.
The Fiplex Digital Master Unit can be fed with a number of Base Stations or Off the Air. The direct connection to
a base station is done though the Point Of Interconnection (POI) and depending on the configuration and amount
of Base Stations it can be something simple as a directional coupler and a duplexer or something more complex
that can consist on several directional couplers, splitters, duplexers.
The Fiplex Digital Master Unit also provides an access point to monitor and control all the system parameters
not only of the Digital Master Unit but also to each Digital Remote Unit connected on the system. This connection
can be done locally via USB or Web-Browser, or remotely using Ethernet (via SNMP protocol).
The DHS00-M and DHS37-R are NFPA Ready orderable with AC or DC option. As optional it can have remote
control via Ethernet or via wireless modem.
The Digital Master Unit and the Digital Remote Units both have heavy duty IP67/NEMA4X cabinet for outdoor
usage, it is designed to be wall or pole mounted, however, to mount on standard 19” rack, a special mounting kit
can be supplied.
For more details refer to the product datasheet.
UM-0909
2.1 Digital Master Unit Ports
The Digital Master Unit is equipped with internal duplexers, therefore, the enclosure has the “To Base” RF Port.
UM-0909
2.2
Digital Remote Unit Ports
The Digital Remote Unit is equipped with internal duplexers, therefore, the enclosure has the “To Mobile” RF
Port.
UM-0909
2.3
FO Connection
2.3.1 FO Connection in Master Unit
Note: Each fiber connection is performed with simplex fiber and LC-APC connector.
UM-0909
2.3.2
FO Connection in Remote Unit
Note: Each fiber connection is performed with simplex fiber and LC-APC connector.
UM-0909
2.4 Dimensions
2.4.1
UM-0909
Digital Master, Expansion and Remote Unit Cabinet Dimensions
10
3
Installation
Mounting the cabinet
Fiplex Digital DAS is designed for outdoor usage with a weather proof outdoor NEMA4 cabinet that can be
mounted without any kind of shelter from rain, snow or hail.
However, to improve reliability, it is recommended to mount the Digital DAS on a site with shelter from direct
exposure to sun, rain, snow and hailing.
It is not recommended to operate the DAS under bad weather conditions, such as:
- Intense rainfall, snowfall or hail
- Storm or high wind
- Extremely low or high temperature
- High humidity of the air
Mounting
1. Mount the bracket
The cabinet can be mounted on a wall or pole. These mounting cases are shown below in Figure 1 and
Figure 2. The bracket is provided with each cabinet.
Figure 1
Figure 1 shows a bracket attachment to a wall using three fixing screws.
Figure 2
Figure 2 shows a bracket attachment to a pipe using four inox hose clamps (provided with bracket).
UM-0909
11
2. After attaching the bracket hang the cabinet as shown in Figure 3.
Figure 3
UM-0909
12
3. Secure the cabinet to the bracket as shown in Figure 4. To attach the cabinet to the bracket use the
provided four M6 x 1/2” allen screws.
Figure 4
UM-0909
13
Opening and Closing the Cabinet
To open the cabinet, release the 8 door screws indicated in figure 5 using the provided special
allen key.
A - Release cabinet cover.
Figure 5
Use the special allen key N°6
UM-0909
14
B - Open the cabinet cover.
Figure 6
C – Close the cabinet cover.
Figure 7
UM-0909
15
D - Secure cabinet cover.
Figure 8
UM-0909
16
Use of Liquid Tight Conduit
The unit has available a Liquid Tight Conduit Fitting connector. The unit as standard has the
connector installed, so if the user requires to use this connector, if available, the NFPA cables,
Ethernet, DC and AC cables can be routed through this connector.
Figure 9; AC Routing through cable gland or conduit connector
If the is not going to use Liquid Tight Conduits, then the connector should be replaced by the
provided sealing cup as indicated in Figure 10.
A - Remove the conduit connector
UM-0909
17
B – Install the sealing cup
Figure 10; Replacement of Conduit connector to sealing cup
Nema4X considerations
This device is equipped with a Nema4X enclosure, however, to ensure the Nema rating,
the user must have the following considerations:
1. Correct use of the Liquid Tight Conduit. In case this interface is not used, it should
be replaced with the sealing cup.
2. Sealing cups should be installed in the non-used cable glands.
3. The RF Ports should be perfectly mated.
UM-0909
18
4
Commissioning
4.1 Connection step by step
Connect the RF ports, Power, Fibers and Ethernet Cable Glands location, for Master, Expansion and Remote
units following the next steps:
1.
For Master Unit:
a. Connect the signal coupled from the base station to the “To Base” RF port. N type female
connectors are used in the unit. The coupling to Base station can be done with a Donor antenna
or through a POI.
b. Connect fiber cables to internal optical modules. LC-APC connectors are used in the unit.
Connect the remote units on the dedicated ports and the expansion units on the dedicated
ports.
c. Connect USB Cable for local management.
2.
For Remote Unit:
a. Connect service antenna (“RF To Mobile” port) coaxial cable to remote unit. N type female
connectors are used in the unit.
b. Connect fiber cable to internal optical module. LC-APC connector is used in the unit.
3.
Once RF ports of the unit are properly loaded connect the Main Power the AC or DC source depending
on the model.
If using the AC model, electrical installation must provide differential and thermo-magnetic breaker
elements according to electric safety international regulations.
DB
TMB
4.
For NFPA connection in Master and Remote, there is a dedicated cable gland for this purpose (“NFPA”
in figure 11 and 12). A multi-conductor cable can be used to connect the NFPA dry contacts to the Fire
Department Control Box.
NC
NO
VSWR
UM-0909
NC
NO
Repeater
Fail
Status of contacts (Alarms Off)
Pin 1 – 2 = VSWR (normally closed contact)
Pin 2 – 3 = VSWR (normally open contact)
Pin 4 – 5 = Repeater Fail (normally closed contact)
Pin 5 – 6 = Repeater Fail (normally open contact)
19
Figure 11; NFPA Dry Contact connection configuration
Figure 12; NFPA Dry Contact connection location inside the cabinet
5.
Once the unit has been connected to the power source, it takes about 30 seconds to run a booting
routine. After that time unit is ready to be connected via USB cable to the Digital Master to a computer
running Fiplex Control Software (FCS) in order to be properly configured.
Figure 13; USB Port location
UM-0909
20
4.2
Starting Operation
BE SURE THAT “TO MOBILE” AND “TO BASE” PORTS ARE PROPERLY
LOADED EITHER WITH 50 OHMS DUMMY LOADS, OR RADIATING SYSTEM.
1.
Turn on the repeater, connect computer to repeater through USB cable, and run Fiplex Control
Software. Check that all remote units are connected to the master through fiber optic checking link
status.
Link status
2.
UM-0909
Enable channel filtering if needed and setup desired channel frequencies. If Fiplex Digital Fiber DAS is
used as channel selective, user has to know what frequencies are used in base station. Each channel
can be enabled independently. Channels not used can be showed / hidden using the “Show channels”
checkboxes. If remote units are on and connected through optical fiber, the corresponding uplink
frequencies will be automatically set, too.
21
Set number of active channels and frequencies
3.
According to DL RF input levels, program input attenuator to avoid input overflow, and output
attenuator for each remote to obtain desired output level in each remote.
Set Input attenuator
Set Output attenuator
4.
UM-0909
Reciprocally, set UL band gain adjusting output attenuator of master unit. It is recommended that DL
gain and UL gain be equal.
22
Set Output attenuator
Check UL and DL gain for each remote
5.
Set up squelch settings. Controls are independent in UL (for each remote) and DL (master) bands.
Typical values for UL are between -110dBm and -100dBm for squelch threshold. For DL,
recommended value for squelch threshold is minimum level received in any active channel minus
10dB.
DL squelch settings
UL squelch settings
6.
UM-0909
Setup desired filter bandwidth, depending on presence of adjacent channels. In principle,
recommended bandwidth filter is 90KHz due to its low delay, but if adjacent signal is detected, narrow
filters can be used. Fine gain can be set to equalize input signals.
23
Filters and fine gain settings
UM-0909
24
4.3 Status Indicators
There is an indicator panel located at the front panel of the repeater. This led panel works as a
status monitor, in order indicate warning or alarms of repeater
There are four leds, first one the power ON indication led, labelled “PWR”.
A Second led, labelled “STS” summarizes warnings regarding critical operational conditions of
the repeater.
Third and fourth led summarizes operational conditions for uplink “UL” and downlink “DL” chains.
In general, leds has four states: off, slow blinking, fast blinking, on. Table 1 describes alarm and
warning conditions for each led state in the master device and Table 2 is for remote devices.
Table 1
Indicator Panel
LED indication description
Unit is not powered or fail in power supply
Normal state: Unit is powered on
Normal state
HW fail: digital signal processor is not detected
Temperature: very high internal unit temperature
Optical fiber alarm in at least one link
TBS Warning: No signal is detected coming from base station
Normal state
RF input overflow: maximum level at RF input is exceeded
Normal state
Where:
Led OFF
Led slow blinking with period of 2 seconds aprox. WARNING
Led fast blinking with period of 0.5 seconds aprox. ALARM
Led ON
UM-0909
25
Table 2
Indicator Panel
LED indication description
Unit is not powered or fail in power supply
Normal state: Unit is powered on
Normal state
HW fail: digital signal processor is not detected
Temperature: very high internal Unit temperature
Optical fiber alarm in at least one link
Normal state
PA Overflow or excessive temperature alarm.
PA Underflow: PA output level is lower than +25dBm
Normal state
Where:
Led OFF
Led slow blinking with period of 2 seconds aprox. WARNING
Led fast blinking with period of 0.5 seconds aprox. ALARM
Led ON
4.4 Laboratory Measurements
For specific parameters verification and laboratory tests, please contact factory.
Detailed procedures, recommended tests set up, and a knowledge engineering team will bring adequate
support to perform this measurements in a comfortable and safely way.
UM-0909
26
Part 2 SOFTWARE
Introduction
Fiplex Fiber DAS can be fully configured and monitored through USB connection. Digital Master
unit receives through optical links monitoring and configuration data from remotes units. For this
reason, whole system can be fully configured and supervised from digital master unit.
USB Software
6.1 Software description (Digital Master)
If software has been successfully installed and connected to Digital Master (see section 7) status
screen will appear. In this screen, RF configurations parameters (channel frequencies,
bandwidth filter, gains / attenuation) and RF and optical links monitoring (RF input/output levels,
AGC status, optical link status) are shown.
At left side of webpage, configuration menus are shown:
 Content
UM-0909

Status: whole RF configuration and monitoring parameters are shown. These
parameters are described in next section.

Tag: user can set a tag to ease repeater identification. For modifying the TAG, write
a new value in text field and click over Apply Changes link
27
UM-0909

IP: At this page (for units with Ethernet supervision), IP addresses configuration and
addresses of SNMP Managers are shown. User can set addresses of two SNMP
Managers (IP where SNMP agent will send TRAP information). To modify, click over
Apply Changes link after writing new values on text fields. Also router 3G IP address
can be viewed in this screen (if 3G router option is installed)

Downlink Spectrum: in order to know input signal: level of desired channels,
unwanted channel levels, Digital Master provides an spectrum analyzer that shows
input signal in frequency domain.

Date & Time (for units with Ethernet supervision): page to modify real time clock.
When the repeater is not powered, this clock runs with a voltage supply provided by
28
a 3V lithium battery, button type of 20mm (CR2032) with 220mA·h. This suffices for
at least half year. When the repeater is powered, no current is drained from the
battery. So, actual battery life will depend on repeater usage. For battery
replacement, please locate battery holder between USB and Ethernet connectors on
main board. Battery positive side is UP, i.e. on holder clip.
After clicking on “Apply Changes” link, next message will appear, warning the user that
system needs to be rebooted.

Configuration
o Apply Changes: as it is said above, this link is used to load changes to the
repeater, in configuration, tag, IP, password and date and time menus. After
any configuration change, web page will show and icon that allows user to
know if configuration has been successfully applied:

Reload Settings: clicking this link, repeater configuration data is refreshed.
Version: shows hardware, firmware and software versions of repeater and serial
number.
6.2 RF parameters description (Digital Master)
“Status” menu shows whole RF configuration and RF and optical links monitoring data that are
distributed along the webpage.
The first frame called “MASTER” is placed in top of webpage, showing configuration of digital
master unit. Below this, some frames titled “REMOTE 1”, “REMOTE 2”... . There is one for each
remote unit connected to the master, and configuration and status information related to each
remote can be viewed. Next figures show these frames:
UM-0909
29

Digital Master frame. There are five sub-sections inside this frame:
Downlink filtering: this section contains fields to modify channel frequencies,
squelch options and filtering options. Parameters are described in following
table:
Parameter
Range
Frequency
Downlink band
Channel enable
Enabled / disabled
90KHz / 45KHz /
30KHz / 20KHz /
15KHz
Bw Filter
Fine Gain Adjust
-5 to +5dB
Power indicator
---
Squelch enable
control
Enabled / disabled
Squelch threshold
control
-90dBm to 40dBm
Filtering enable
Enabled / disabled
UM-0909
Description
Downlink frequency channels. Frequency
resolution is 3.125KHz
Each of 12 channels can be enabled/disabled
Bandwidth of channels filter can be
independently adjusted (if filtering is enabled)
If filtering is enabled, gain of each channel can
be fine adjusted
Level of each channel, measured according to
its bandwidth filter, is shown in dBm units. Led
indicator shows if levels exceeds squelch
threshold (green) or not (yellow).
Enabling this control, repeater does not transmit
in each channel if RF input power do not exceed
the threshold level configured according to next
row
If squelch is enabled, input levels below this
threshold are not transmitted.
Filtering option can be bypassed. If filtering is
disabled, fine gain adjustments and squelch
options are ignored
Master RF Input parameters. Next table describes information of this frame:
Parameter
Range
Broad band level
---
Description
This indicator shows input level measured along
DL band
30
Overflow
Grey: normal state /
Red: alarm state
Input Attenuator RF IN from TBS
(DL)
0dB to 30dB
Master RF Output parameters. Next table describes information of this frame:
Parameter
UL Output power
Range
---
AGC
Grey: normal state /
Red: alarm state
Output Attenuator
RF OUT to Base
Station (UL)
0dB to 30dB
This indicator shows overflow on input circuitry is
occurring. This condition can be avoided
increasing input attenuator
Input attenuator to accommodate input levels.
This value must be set to avoid overflow
condition. Together with output attenuator of
remotes sets the downlink gain:
G_DL (dB) = 80 – AttINmaster(dB) –
AttOUTremote(dB)
Description
This indicator shows output level in UL band
This indicator shows gain reduction that master
unit is applying at RF output to prevent PA UL
overload
Output attenuator to adjust UL gain. System UL
gain can be computed as:
G_UL (dB) = 80 – AttOUTmaster(dB)
Master Board status: general parameters of master unit are contained in this
frame
Parameter
Temperature
High temperature
alarm
Signal processor
alarm
RESET control
Range
--Grey: normal state /
Red: alarm state
Grey: normal state /
Red: alarm state
---
Description
This indicator shows unit temperature
High temperature alarm condition is indicated
with this led.
Alarm indicates that digital signal processor is
not working properly.
With this control, unit can be restarted

UM-0909
31
o

Optical link status: each indicator shows optical link status between digital
master and each remote unit. Clicking on “REMOTE LINK n” detailed monitoring
data of each optical link can be viewed: voltage, current and temperature of
each optical module, transmitted and received optical power, and alarms related
to digital data recovery system. If Expansion Unit is used to increase number of
remote units a new frame appears with “EXPANSOR LINK n” title, showing link
status (between Digital Master and Expansion Unit). Data of two optical modules
involved in each link are shown: master unit side (or expansion unit side) and
remote unit side.
Remote frame: shows configuration and monitoring information of each remote unit. The
frame is divided in the following sections:
Uplink filtering: this section shows equivalent parameters of downlink filtering of
master unit.
Parameter
Range
Frequency
UL band
Channel enable
Enabled / disabled
90KHz / 45KHz /
30KHz / 20KHz /
15KHz
Bw Filter
UM-0909
Fine Gain Adjust
-5 to +5dB
Power indicator
---
AGC
---
Squelch enable
control
Enabled / disabled
Squelch threshold
control
-110dBm to -70dBm
Description
Uplink frequency channels. These frequencies
are derived automatically from downlink
frequencies, taking into account frequency
separation between DL and UL bands
Each of 12 channels can be enabled/disabled
Bandwidth of channels filter can be
independently adjusted (if filtering is enabled)
If filtering is enabled, gain of each channel can
be fine adjusted
Level of each channel, measured according to
its bandwidth filter, is shown in dBm units. Led
indicator shows if levels exceeds squelch
threshold (green) or not (yellow).
Show gain reduction to prevent overloading in
AGC per channel
Enabling this control, repeater does not transmit
in each channel if RF input power do not exceed
the threshold level configured according to next
row
If squelch is enabled, input levels below this
threshold are not transmitted.
32
Filtering enable
Filtering option can be bypassed. If filtering is
disabled, fine gain adjustments and squelch
options are ignored
Remote RF Input parameters. Next table describes information of this frame:
Parameter
Range
Broad band level
---
Overflow
Grey: normal state /
Red: alarm state
Uplink gain from
remote to master
--
Description
This indicator shows input level measured in UL
band
This indicator shows overflow on input circuitry is
occurring.
Shows system uplink gain for each remote. Can
be calculated as:
G_UL (dB) = 80 – AttOutMaster(dB)
Remote RF Output parameters. Next table describes information of this frame:
Parameter
Output power
level
Range
Description
---
This indicator shows the PA output power
PA Overflow
Grey: normal state /
Red: alarm state
Downlink gain
from master to
remote
---
AGC
---
Indicates that PA is overloaded. Condition is
output power higher than +43dBm
Shows downlink gain for each remote. Can be
calculated as:
G_DL (dB) = 80 – AttInMaster(dB) –
AttOutRemote(dB)
Shows gainr reduction applied in DL band signal
to prevent PA overload
UM-0909
Enabled / disabled
RF on/off control and Board Status:
Parameter
Range
RF on/off
Indicator
Green: RF Enabled
/ Red: RF Disabled
RF Enable Control
On / Off
Description
This indicator shows PA status. Power amplifier
can be automatically disabled if other alarm
conditions occurs:
a) Fail in optical link
b) PA Overflow
With this control RF DL and UL chains can be
disabled
33
Output attenuator
0 to 40dB
Temperature
High temperature
alarm
RESET control
--Grey: normal state /
Red: alarm state
---
This control sets the output attenuation used to
set DL gain together with Master Input
Attenuator
This indicator shows unit temperature
High temperature alarm condition is indicated
with this led.
With this control, unit can be restarted

Optical link status: shows optical link status between master and each remote
unit. Moreover, clicking on “REMOTE LINK n” detailed monitoring data of each
optical link can be viewed: voltage, current and temperature of each optical
module, transmitted and received optical power, and alarms related to digital
data recovery system. The main window shows only general parameters:
Parameter
Range
Frequency Sync
Green: Normal state /
Red: Alarm state
Status
Rx Detect
Green: Normal state
Yellow: Warning state
Red: Alarm state
Green: Normal state
Yellow: Warning state
Red: Alarm state
Error Count
---
Rx Power
---
Description
This indicator shows frequency
synchronization status between master and
remote unit
This indicator summarizes the status of optical
module based in voltage, current, temperature
and optical transmitted power
This indicator summarizes the status of optical
reception based in received optical power and
digital data recovery system
Counter that it is incremented when optical link
fails.
Shows optical received power. For reliable
optical link, RX power must be higher than
-25dBm
6.3 Software description (Remote Unit)
While software connected to digital master allows configuration and monitoring of whole system, if
software is connected to remote unit, only parameters of this unit can be viewed / modified.
Then, status screen of remote unit only shows information regarding this unit:
UM-0909
34
Distribution and meaning of the controls contained in status page are very similar to single remote
frame of master status page, only optical frame is different due to only remote side of optical link is
monitored.
Local Software. Installation and troubleshooting
7.1 Installation
The following section will describe the steps to be followed in order to install and use the Fiplex
Control software with your Fiplex repeater.
1. Before connect USB cable between computer and repeater, run the
FiplexControlSoftware.msi File. Next screen will appear…
UM-0909
35
2.
Choose the default installation path “C:\Program Files (x86)\FiplexControlSoftware”. Note that this
can change according to your system configuration (32bits or 64bits), language and Windows
Version.
3. The installer will start to copy the necessary files.
4. After installation has completed, a shortcut in user desktop will appear.
UM-0909
36
5. Connect USB cable between computer and repeater, keeping the repeater powered off.
Usually, drivers will be automatically installed, but depending on Windows version, screen
asking for drivers of new device can appear. Drivers can be found in application folder:
C:\Program Files (x86)\FiplexControlSoftware\drivers”.
6. Turn on the Repeater
BE SURE THAT “TO MOBILE” AND “TO BASE” PORTS ARE PROPERLY
LOADED EITHER WITH 50 OHMS DUMMY LOADS, OR RADIATING SYSTEM.
7. Execute the Fiplex Control Software. Next window will appear:
UM-0909
37





User interface has the following controls:
Scan Devices Button: refresh the available COM ports and identify Fiplex devices
Connection Button: connect / disconnect software from repeater
List of available devices: below two buttons, is placed a dropdown list that shows all
available COM ports. Available COM ports not related to Fiplex devices will be shown
with its number and “Unknown device” label. COM ports related to Fiplex devices will
show a device description.
Embedded Web browser: graphical area where configuration and monitoring parameters
will be shown.
File menu: contains menus to save repeater configuration to a file and load configuration
from file to repeater.
NOTE: if Fiplex Repeater is not turned on, related COM port will appear as “Unknown
device”
8. Click “Scan Devices”
UM-0909
38
Now, the Fiplex unit is shown in the list of available devices, and connection button is
enabled.
NOTE: Fiplex repeater could not appear in list, if COM port number is higher than
COM16, depending on Windows version. COM port number can be forced to arbitrary
number (below COM16) through Device Administrator. In order to change COM number,
click “Properties” pop-up menu:
Click “Advanced Options”
UM-0909
39
Change COM port number
9. Click “Connect”. Fiplex Control Software window will be automatically maximized, and it
will show the configuration screen described in previous sections.
UM-0909
40
10. Once system is configured, user can disconnect software using connection button, now
labelled “Disconnect”. Initial window will be shown.
If repeater is disconnected or turned off, while Fiplex Control Software is connected to
device, software will go back to initial window. Moreover, if some communication problem
occurs while device is monitored, the software will go back to initial state as well.
11. Remote unit can be controlled through USB port. In this case, Fiplex Control Software will
show that connected device is a remote unit.
After click on “Connect” button, program will show only remote configuration and
monitoring parameters, with same graphical interface described in previous sections:
UM-0909
41
UM-0909
42

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 46
Language                        : es-AR
Tagged PDF                      : Yes
Title                           : TETRA User's Manual
Author                          : gponcedeleon
Creator                         : Microsoft® Word 2013
Create Date                     : 2017:10:20 17:24:31-03:00
Modify Date                     : 2017:10:20 17:24:31-03:00
Producer                        : Microsoft® Word 2013
EXIF Metadata provided by EXIF.tools
FCC ID Filing: P3TDHS37-R

Navigation menu