First Act M2A 110 Users Manual

M2A-110 to the manual 3c71232a-0203-4173-b54f-4768b8e4693b

2015-01-23

: First-Act First-Act-M2A-110-Users-Manual-221767 first-act-m2a-110-users-manual-221767 first-act pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadFirst-Act First-Act-M2A-110-Users-Manual-  First-act-m2a-110-users-manual
Open PDF In BrowserView PDF
IMPORTANT SAFETY INSTRUCTIONS

Please read carefully before operating your amplifier:
Follow these basic precautionary measures to ensure a longer life for your amplifier, and to reduce
the risk of electric shock.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. The apparatus should not be exposed to dripping
or splashing. No objects filled with liquids, such as
vases, should be placed on apparatus.
6. Clean only with dry cloth.
7. Do not block any ventilation openings, maintaining
a minimum distance of 10cm around the appartus.
Install in accordance with the manufacturer’s
instructions.
8. Do not install near any heat sources such as
radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. No
naked flame sources such as lighted candles should
be placed on the appartus.
9. Do not defeat the safety purpose of the polarized
or grounding-type plug. A polarized plug has two
blades with one wider than the other. A grounding type has two blades and a third grounding
prong. The wide blade or the third prong are
provided for your safety. If the provided plug does
not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10. Protect the power cord from being walked on or
pinched particularly at plugs, convenience receptacles, and the point where they exit from the
apparatus.

11. Only use attachments/accessories specified by
the manufacturer.
12. Unplug this apparatus during lightning storms
or when unused for long periods of time.
13. Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has
been damaged in any way, such as power-supply
cord or plug is damaged, liquid has been spilled
or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture,
does not operate normally, or has been dropped.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT
REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS
INSIDE, REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

THE LIGHTENIING FLASH WITH ARROWHEAD SYMBOLS, WITH AN EQUILATERAL TRIANGLE
IS INTENDED TO ALERT THE USER TO THE PRESENCE OF UNINSULATED “DANGEROUS
VOLTAGE” WITHIN THE PRODUCT’S ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE TO
CONSISTITUTE A RISK OF ELECTRIC SHOCK TO PERSONS.
THE EXCLAMATION POINT WITHIN AN EQUILATERAL TRIANGLE IS INTENED TO ALERT THE
USER TO THE PRESENCE OF IMPORTANT OPERATING AND MAINTENANCE (SERVICING)
INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THE APPLIANCE.

WARNING: EXCESSIVE SOUND PRESSURE FROM EARPHONES AND HEADPHONES CAN
CAUSE HEARING LOSS.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS
APPARATUS TO RAIN OR MOISTURE.
MAINS PLUG IS USED AS DISCONNECT DEVICE AND IT SHOULD REMAIN READILY OPERABLE DURING INTENTED USE. IN ORDER TO DISCONNECT THE APPARATUS FROM THE
MAINS COMPLETELY, THE MAINS PLUG SHOULD BE DISCONNECTED FROM THE MAINS
SOCKET COMPLETELY.
THE APPARATUS SHALL BE CONNECTED TO MAINS SOCKET OUTLET WITH A PROTECTIVE
EARTHING CONNECTION.

First Act Inc.
745 Boylston Street
Boston, MA 02116 USA
firstact.com
Guitar Case

10 & 20ft Cables

Auto Tuner

Picks

Books

Guitar Strings

Stringwinder

OTHER
FIRST ACT®
PRODUCTS :

M2A-110

AMPLIFIER
INSTRUCTION

MANUAL
Customer Assistance
Phone: 888.551.1115
Email: info@firstact.com
First Act and the First Act logo are
trademarks of First Act Inc.
US Patent No. D487,627
©2008 First Act Inc.
All rights reserved.
M2A110.M.06

FACEPLATE

1

2

3

4

5

6

7

8

BACKPLATE

9

10

11

12

1.	 INPUT JACK
Connect instrument cable here (1/4 inch jack).

7.	 MIDDLE
Adjusts middle frequency output.

2.	 MASTER VOLUME
Controls the total output level of amplifier.

8.	 BASS
Adjusts low frequency output.

3.	 GAIN
Controls the input level. Increasing gain
adds distortion, or an overdriven rock tone;
decreasing gain produces a cleaner sound.
Gain knob is functional when Overdrive
button is engaged.

9.	 POWER
On/off switch.

4.	 OVERDRIVE ON/OFF SWITCH
ON selects the Overdrive (distortion) channel,
OFF selects the Clean channel. The GAIN
knob interacts with the overdrive button,
allowing the user to add the desired amount
of distortion.

11.	 AUDIO IN
Input jack for external audio device such as
CD, MP3, or cassette player (device should
have its own volume control).

5.	 LED
Indicates power on /off.

10.	 PHONES
Connects to stereo headphones, which cancels
speaker output.

12.	 POWER INPUT / FUSE COMPARTMENT
Connection for power cable. Use only the
power cable supplied with this amplifier.
See instructions below for replacing the fuse.

6.	 TREBLE
Adjusts high frequency output.

SPECIFICATIONS
Output Power:
10 watts RMS
Frequency Range:
40 Hz ~ 8 kHz
Speaker:
6.5" / 25W / 8 ohms

Input Sensitivity:
26 mV
Power Supply:
Detachable,
UL-approved
	 power cable

Dimensions: (LxWxH)
12" x 7.4" x 12"
Weight:
12 lbs.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

REPLACING THE FUSE

The fuse compartment contains an active fuse.
The fuse protects against power surges. If your
amplifier does not power up as usual, this fuse
may need to be replaced.
If the fuse fails:
1.	 Turn the amplifier power off.
2.	 Unplug the amplifier.
3.	 Detach the power cord and set aside.
4.	 Carefully insert a flathead screwdriver to
	 open the fuse compartment. Be careful not
	 to break the fuse inside.
5.	 Remove the blown fuse from the inner
	 (active) slot.
6.	 Replace with a 250V, 500mA fuse.
7.	 Close the fuse compartment.
8.	 Discard the blown fuse.

Open the fuse compartment.

Note: If you replace the fuse and the amplifier
still does not power up, have the unit checked by
a qualified repairperson.
ACTIVE FUSE

CAUTION

REPLACE ONLY WITH SAME
TYPE 250V, 500mA FUSE.
USING ANOTHER TYPE IS A POTENTIAL FIRE HAZARD.

Remove the blown fuse from the inner (active)
slot.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c006 1.236519, Wed Jun 14 2006 08:31:24
Create Date                     : 2008:05:28 17:00:48-04:00
Metadata Date                   : 2008:05:28 17:01:13-04:00
Modify Date                     : 2008:05:28 17:01:13-04:00
Creator Tool                    : Adobe InDesign CS3 (5.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 8169 bytes, use -b option to extract)
Instance ID                     : uuid:a9f923a4-ff67-49f5-b810-0d18eefffa07
Document ID                     : adobe:docid:indd:4c8c9d7e-f11a-11dc-8e94-9cd83d121112
Rendition Class                 : proof:pdf
Derived From Instance ID        : 11db8ff6-f8b3-11db-b3e9-bfc4130a1b2a
Derived From Document ID        : adobe:docid:indd:adfb5675-f5a2-11db-8278-8887b7b2c527
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 72.00, 72.00
Manifest Placed Y Resolution    : 300.00, 300.00, 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:AAFAA7392E5E11DDAEC1DABF33E1ED4D, uuid:14FBE74669EB11DBAEBBADA2362898C2, uuid:3F97C8C1F5B111DBAE778418B0F4831E, uuid:3F97C8B9F5B111DBAE778418B0F4831E, uuid:F91AD4586A8311DBB89BD35415E65B4F, uuid:DFB553E16A8311DBB89BD35415E65B4F, uuid:DFB553DD6A8311DBB89BD35415E65B4F, uuid:DFB553D96A8311DBB89BD35415E65B4F, uuid:a1dec100-cfc3-11da-a23e-000d93428820, uuid:798ec7b0-f80d-11dc-8a78-0016cb37b368
Manifest Reference Document ID  : adobe:docid:photoshop:699d423a-ba86-11da-8061-ba8ef7ccad91, adobe:docid:photoshop:be911e04-bb24-11da-9ce9-93f6ef49de10, uuid:77D115A0D1EE11DAAD0BDF679816D4F8, adobe:docid:photoshop:a02e57ab-bf0f-11da-a39d-99472bf7da77, adobe:docid:photoshop:65d9370a-c238-11da-8b59-9b60eb90e7b5, adobe:docid:photoshop:adc29049-bb2c-11da-9ce9-93f6ef49de10, uuid:D869D8CCD06311DAAD0BDF679816D4F8, adobe:docid:photoshop:ccfa9d9d-bb22-11da-9ce9-93f6ef49de10, uuid:E70C1149CE0311DA9B49DE7C284FF3C5, uuid:E70C114BCE0311DA9B49DE7C284FF3C5
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS3 (5.0)
EXIF Metadata provided by EXIF.tools

Navigation menu