IMPORTANT!
PLEASE READ CAREFULLY AND SAVE.
This user’s manual contains important information about your Smoke
Alarm’s operation. If you are installing this Smoke Alarm for use by
others, you must leave this manual—or a copy of it—with the end user.
USER’S MANUAL
Printed in Mexico
M08-0020-002 J1 07/04 Model SA87B, SA97B
SMOKE ALARM WITH
SILENCE FEATURE
SMOKE ALARM WITH
SILENCE FEATURE AND
LONG-LIFE LITHIUM POWER
TABLE OF CONTENTS
Fire Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Before You Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . .1
How To Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . .2
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
If This Smoke Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
What To Do In Case Of Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Using the Silence Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
If You Suspect A Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Recommended Locations For Smoke Alarms . . . . . . . . . . . . . . .4-5
Locations To Avoid For Smoke Alarms . . . . . . . . . . . . . . . . . . . . . .5
About Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . .6
Limitations Of Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
All Rights Reserved. © 2004 BRK Brands, Inc.
BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: (800) 323-9005 www.firstalert.com
FIRE SAFETY TIPS
Follow safety rules and prevent hazardous situations: 1) Use smoking
materials properly. Never smoke in bed. 2) Keep matches or lighters
away from children; 3) Store flammable materials in proper containers;
4) Keep electrical appliances in good condition and dont overload elec-
trical circuits; 5) Keep stoves, barbecue grills, fireplaces and chimneys
grease- and debris-free; 6) Never leave anything cooking on the stove
unattended; 7) Keep portable heaters and open flames, like candles,
away from flammable materials; 8) Dont let rubbish accumulate.
Keep alarms clean, and test them weekly. Replace alarms immediately if
they are not working properly. Smoke Alarms that do not work cannot alert
you to a fire. Keep at least one working fire extinguisher on every floor, and
an additional one in the kitchen. Have fire escape ladders or other reliable
means of escape from an upper floor in case stairs are blocked.
*All First Alert®Smoke Alarms conform to regulatory requirements,
including UL217 and are designed to detect particles of combustion.
Smoke particles of varying number and size are produced in all fires.
Ionization technology is generally more sensitive than photoelectric
technology at detecting small particles, which tend to be produced
in greater amounts by flaming fires, which consume combustible
materials rapidly and spread quickly. Sources of these fires may include
paper burning in a wastebasket, or a grease fire in the kitchen.
Photoelectric technology is generally more sensitive than ionization
technology at detecting large particles, which tend to be produced
in greater amounts by smoldering fires, which may smolder for
hours before bursting into flame. Sources of these fires may include cig-
arettes burning in couches or bedding.
For maximum protection, use both types of Smoke Alarms on each
level and in every bedroom of your home.
1
SMOKE AND FIRE* ALARM
This unit will not alert hearing impaired residents. It is recom-
mended that you install special units which use devices like
flashing strobe lights to alert hearing impaired residents.
Do not connect this unit to any other alarm or auxiliary device. It
is a single-station unit that cannot be linked to other devices.
Connecting anything else to this unit may prevent it from working
properly.
Unit will not operate without battery power. The Smoke Alarm
cannot work until you install the battery in the correct position
(Match + to + and - to -).
This Smoke Alarm has a battery guard which prevents it from
closing unless a battery is installed. This warns you the unit will
not operate without a battery.
Do not install this unit over an electrical junction box. Air cur-
rents around junction boxes can prevent smoke from reaching
the sensing chamber and prevent the unit from alarming. Only
AC powered units are intended for installation over junction
boxes.
Do not stand too close to the unit when the alarm is sounding. It
is loud to wake you in an emergency. Exposure to the horn at
close range may harm your hearing.
Do not paint over the unit. Paint may clog the openings to the
sensing chamber and prevent the unit from operating properly
BEFORE YOU INSTALL THIS SMOKE ALARM
IMPORTANT! Read Recommended Locations for Smoke Alarms and
Locations to Avoid for Smoke Alarms before beginning. This unit
monitors the air, and when smoke reaches its sensing chamber, it
alarms. It can give you more time to escape before fire spreads. This
unit can ONLY give an early warning of developing fires if it is installed,
maintained and located where smoke can reach it, and where all resi-
dents can hear it, as described in this manual. This unit will not sense
gas, heat, or flame. It cannot prevent or extinguish fires.
Understand The Different Type of Smoke Alarms
Battery powered or electrical? Different Smoke Alarms provide
different types of protection. See About Smoke Alarms for details.
Know Where To Install Your Smoke Alarms
Fire Safety Professionals recommend at least one Smoke Alarm on
every level of your home, in every bedroom, and in every bedroom hall-
way or separate sleeping area. See Recommended Locations For
Smoke Alarms and Locations To Avoid For Smoke Alarms for details.
Know What Smoke Alarms Can and Cant Do
A Smoke Alarm can help alert you to fire, giving you precious time to
escape. It can only sound an alarm once smoke reaches the sensor.
See Limitations of Smoke Alarms for details.
Check Your Local Building Codes
This Smoke Alarm is designed to be used in a typical single-family
home. It alone will not meet requirements for boarding houses, apart-
ment buildings, hotels or motels. See Special Compliance
Considerations
for details.
1
2
3
45
67
5
HOW TO INSTALL THIS SMOKE ALARM
THE PARTS OF THIS SMOKE ALARM
FOLLOW THESE SIMPLE STEPS!
1. OPEN HEREtab
2. Cover hinge
3. Test button,
power/alarm indicator
4. Silence button
1. OPEN HEREtab
2. Test button, power/alarm
indicator
3. Silence button
4. Smoke Alarm base
5. Mounting slots
6. DO NOT install any
battery here!
7. Install 9V battery here
This unit is designed to be mounted on the
ceiling, or on the wall if necessary.
Tools you will need:
Pencil
Drill with 3/16 (5 mm) drill bit
Standard/Flathead screwdriver
Hammer
1. Hold base firmly and pull up on cover tab
marked OPEN HERE. This will open the
hinged cover. The cover may unsnap from
the base if it's opened too far. This will not
damage the unitthe cover hinge snaps
back into place easily.
2. Hold the Smoke Alarm base against the
ceiling (or wall) and make a mark at the
center of each of the mounting slots with
a pencil.
3. Put the unit where it wont get covered
with dust when you drill the mounting
holes.
4. Using a 3/16 (5 mm) drill bit, drill a hole
through each pencil mark.
5. Insert the plastic screw anchors (in the
plastic bag with screws) into the holes.
Tap the screw anchors gently with a ham-
mer, if necessary, until they are flush with
the ceiling or wall.
6. Tighten the screws (provided) into the
screw anchors, then loosen them two
turns.
10
11
8
9
6
7
3
5
4
1
2
7. Fit the Smoke Alarm over the screw heads
as shown. Close cover.
8. If the Smoke Alarm cover does not line up
the way you want it, rotate the base and
re-tighten the screws.
9. Activate the battery. With the cover open,
remove and reinstall the battery so the ter-
minals on the battery match the terminals
on the Smoke Alarm. Match + to + and
- to -. Push the battery in until it snaps
in securely and cannot be shaken loose.
If the battery is not snapped in completely,
the unit cannot receive battery power. The
Smoke Alarm may beep briefly when you
install the batterythis is normal.
Once the battery is installed, the power
indicator light (behind the test button) will
flash once a minute to show you the
Smoke Alarm is working.
10. Close the cover all the way.
11. Test the Smoke Alarm. See Weekly
Testing.
2
WEEKLY TESTING
NEVER use an open flame of any kind to test this unit. You
might accidentally damage or set fire to the unit or to your
home. The built-in test switch accurately tests the units opera-
tion as required by Underwriters Laboratories, Inc. (UL). If you
choose to use an aerosol smoke product to test the Smoke
Alarm, be certain to use one that has been Listed to
Underwriters Laboratories, Inc. Safety Standards, and use it
only as directed. Use of non-UL Listed products or improper use
of UL Listed products may affect the Smoke Alarms sensitivity,
and may void your warranty.
If the Alarm ever fails to test properly, replace it immediately.
Products under warranty may be returned to the manufacturer
for replacement. See Limited Warranty for details.
DO NOT stand close to the alarm when the horn is sounding.
Exposure at close range may be harmful to your hearing. When
testing, step away when horn starts sounding.
It is important to test this unit every week to make sure it is work-
ing properly. Using the test button is the recommended way to test this
Smoke Alarm. During testing, you will hear a loud, repeating horn pat-
tern: 3 beeps, pause, 3 beeps, pause.
IF THIS SMOKE ALARM SOUNDS
RESPONDING TO AN ALARM
During an alarm, you will hear a loud, repeating horn pattern:
3 beeps, pause, 3 beeps, pause.
If the unit alarms and you are not testing the unit, it is warning
you of a potentially dangerous situation that requires your
immediate attention. NEVER ignore any alarm. Ignoring the
alarm may result in injury or death.
Never remove the batteries from a battery operated Smoke
Alarm to stop an unwanted alarm (caused by cooking smoke,
etc.). Removing batteries disables the alarm so it cannot sense
smoke, and removes your protection. Instead open a window
or fan the smoke away from the unit. The alarm will reset
automatically.
If the unit alarms get everyone out of the house immediately.
WHAT TO DO IN CASE OF FIRE
Dont panic; stay calm. Follow your family escape plan.
Get out of the house as quickly as possible. Dont stop to get
dressed or collect anything.
Feel doors with the back of your hand before opening them.
If a door is cool, open it slowly. Dont open a hot door. Keep doors
and windows closed, unless you must escape through them.
Cover your nose and mouth with a cloth (preferably damp).
Take short, shallow breaths.
Meet at your planned meeting place outside your home, and do a
head count to make sure everybody got out safely.
Call the Fire Department as soon as possible from outside.
Give your address, then your name.
Never go back inside a burning building for any reason.
Contact your Fire Department for ideas on making your home safer.
Alarms have various limitations. See "Limitations of Smoke Alarms"
for details.
USING THE SILENCE FEATURE
The Silence Feature can temporarily quiet an unwanted alarm for several
minutes. To use this feature, press the Push to Silence button on the
cover. The alarm will chirp about once a minute (for up to 15 minutes)
to remind you the alarm has been silenced. The chirping will stop
when the unit returns to normal operation.
The Silence Feature does not disable the unitit makes it tem-
porarily less sensitive to smoke. For your safety, if smoke around
the unit is dense enough to suggest a potentially dangerous situa-
tion, it will stay in alarm, or may re-alarm quickly. If you do not
know the source of the smoke, do not assume it is an unwanted
alarm. Not responding to an alarm can result in property loss,
injury or death.
3
REGULAR MAINTENANCE
This unit has been designed to be as maintenance free as possible, but
there are a few simple things you must do to keep it working properly.
Use only the replacement batteries listed below. The unit may not
operate properly with other batteries. Never use rechargeable
batteries since they may not provide a constant charge.
Test it at least once a week.
Clean the Smoke Alarm at least once a month; gently vacuum the
outside of the Smoke Alarm using your household vacuums soft
brush attachment. Test the Smoke Alarm. Never use water, cleaners
or solvents since they may damage the unit.
If the Smoke Alarm becomes contaminated by excessive dirt, dust
and/or grime, and cannot be cleaned to avoid unwanted alarms,
replace the unit immediately.
Relocate the unit if it sounds frequent unwanted alarms. See
Locations to Avoid for Smoke Alarms for details.
When the battery becomes weak, the Smoke Alarm unit will chirp
about once a minute (the low battery warning). This low battery
warning should last for 30 days, but you should replace the battery
immediately to continue your protection.
Choosing a replacement battery:
Your Smoke Alarm requires one standard 9V battery. The following bat-
teries are acceptable as replacements: Duracell #MN1604, (Ultra)
#MX1604; Eveready (Energizer) #522. You may also use a Lithium bat-
tery like the Ultralife U9VL-J for longer service life between battery
changes. These batteries are available at many local retail stores.
Actual battery service life depends on the Smoke Alarm and the environ-
ment in which it is installed. All the batteries specified above are accept-
able replacement batteries for this unit. Regardless of the manufacturers
suggested battery life, you MUST replace the battery immediately once
the unit starts chirping (the low battery warning).
Model SA97B Only:
This model was shipped with a 10-Year Extended Life Lithium battery.
When you replace the original battery, you must replace it with a 10-Year
Extended Life Lithium battery for continued long-life power between
battery changes.
LIMITED WARRANTY
BRK Brands, Inc., ("BRK") the maker of First Alert®brand products
warrants that for a period of ten years from the date of purchase, the
Model SA97B will be free from defects in material and workmanship.
In addition, BRK warrants that for a period of five years from the date of
purchase, the Model SA87B will be free from defects in material and
workmanship. BRK, at its option, will repair or replace this product or
any component of the product found to be defective during the warranty
period. Replacement will be made with a new or remanufactured prod-
uct or component. If the product is no longer available, replacement
may be made with a similar product of equal or greater value. This is
your exclusive warranty.
This warranty is valid for the original retail purchaser from the date of
initial retail purchase and is not transferable. Keep the original sales
receipt. Proof of purchase is required to obtain warranty performance.
BRK dealers, service centers, or retail stores selling BRK products do
not have the right to alter, modify or any way change the terms and
conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting
from any of the following: negligent use or misuse of the product, use on
improper voltage or current, use contrary to the operating instructions,
disassembly, repair or alteration by anyone other than BRK or an author-
ized service center. Further, the warranty does not cover Acts of God,
such as fire, flood, hurricanes and tornadoes or any batteries that are
included with this unit.
BRK shall not be liable for any incidental or consequential damages
caused by the breach of any express or implied warranty. Except to the
extent prohibited by applicable law, any implied warranty of mer-
chantability or fitness for a particular purpose is limited in duration to the
duration of the above warranty. Some states, provinces or jurisdictions
do not allow the exclusion or limitation of incidental or consequential
damages or limitations on how long an implied warranty lasts, so the
above limitations or exclusion may not apply to you. This warranty gives
you specific legal rights, and you may also have other rights that vary
from state to state or province to province.
How to Obtain Warranty Service
Service: If service is required, do not return the product to your retailer.
In order to obtain warranty service, contact the Consumer Affairs
Division at 1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time,
Monday through Friday. To assist us in serving you, please have the
model number and date of purchase available when calling.
303 Nelson Avenue, Neosho, MO 64850-8806.
Battery: BRK Brands, Inc. make no warranty, express or implied, written
or oral, including that of merchantability or fitness for any particular
purpose with respect to battery.
IF YOU SUSPECT A PROBLEM
Smoke Alarms may not operate properly because of dead, missing or
weak batteries, a build-up of dirt, dust or grease on the Smoke Alarm
cover, or installation in an improper location. Clean the Smoke Alarm as
described in Regular Maintenance, and install a fresh battery, then test
the Smoke Alarm again. If it fails to test properly when you use the test
button, or if the problem persists, replace the Smoke Alarm immediately.
If you hear a chirp once a minute, replace the battery.
If you experience frequent non-emergency alarms (like those
caused by cooking smoke), try relocating the Smoke Alarm.
If the alarm sounds when no smoke is visible, try cleaning or
relocating the Smoke Alarm. The cover may be dirty.
If the alarm does not sound during testing, try installing a new
battery, and make sure it is snapped in securely.
If the Smoke Alarm is still not operating properly, and it is still under
warranty, please see How to Obtain Warranty Service in the Limited
Warranty below.
Do not try fixing the alarm yourself this will void your warranty!
RECOMMENDED LOCATIONS FOR
SMOKE ALARMS
Installing Smoke Alarms in Single-Family Residences
The National Fire Protection Association (NFPA), recommends one
Smoke Alarm on every floor, in every sleeping area, and in every bed-
room. In new construction, the Smoke Alarms must be AC powered and
interconnected. See Agency Placement Recommendations for details.
For additional coverage, it is recommended that you install a Smoke
Alarm in all rooms, halls, storage areas, finished attics, and basements,
where temperatures normally remain between 40˚F (4˚C) and 100˚F
(38˚C). Make sure no door or other obstruction could keep smoke from
reaching the Smoke Alarms.
More specifically, install Smoke Alarms:
On every level of your home, including finished attics and base-
ments.
Inside every bedroom, especially if people sleep with doors closed.
In the hall near every sleeping area. If your home has multiple sleep-
ing areas, install a unit in each.
If a hall is over 40 feet (12 meters) long, install an alarm at each end.
At the top of the first-to-second floor stairway, and at bottom of
basement stairway.
Specific requirements for Smoke Alarm installation vary from state to
state and from region to region. Check with your local Fire Department
for current requirements in your area. It is recommended AC or AC/DC
units be interconnected for added protection.
4
BEDROOM
BEDROOM HALL
LIVING ROOM KITCHEN
FINISHED BASEMENT
BEDROOM
BEDROOM LIVING ROOM
DINING ROOM
MULTI-STORY RESIDENCE
SINGLE-STORY RESIDENCE, APARTMENT,
MOBILE HOME
EXISTING HOMES
KITCHEN
REQUIRED TO
MEET NFPA
RECOMMENDATIONS
RECOMMENDED
FOR ADDITIONAL
PROTECTION
KEY: SMOKE ALARMS WITH SILENCE
FEATURES RECOMMENDED FOR
ADDITIONAL PROTECTION
INTERCONNECTED
AC OR AC/DC
SMOKE ALARMS
BEDROOM
BEDROOM HALL
LIVING ROOM KITCHEN
FINISHED BASEMENT
REQUIRED TO
MEET NFPA
RECOMMENDATIONS
RECOMMENDED
FOR ADDITIONAL
PROTECTION
BEDROOM
BEDROOM LIVING ROOM
DINING ROOM
MULTI-STORY RESIDENCE
SINGLE-STORY RESIDENCE, APARTMENT,
MOBILE HOME
KEY:
NEW CONSTRUCTION
SMOKE ALARMS
WITH SILENCE
FEATURES
RECOMMENDED
FOR ADDITIONAL
PROTECTION
KITCHEN
INSTALLING SMOKE ALARMS IN MOBILE HOMES & RVS
For minimum security install one Smoke Alarm as close to each sleeping
area as possible. For more security, put one unit in each room. Many
older mobile homes (especially those built before 1978) have little or no
insulation. If your mobile home is not well insulated, or if you are unsure
of the amount of insulation, it is important to install units on inside walls
only. Smoke Alarms should be installed where temperatures normally
remain between 40˚F (4˚C) and 100˚F (38˚C). WARNING: Test units used
in RVs after the vehicle has been in storage, before every trip, and
once a week while in use. Failure to test units used in RVs as
described may remove your protection.
This equipment should be installed in accordance with NFPA (National Fire
Protection Association) 72 and
101. National Fire Protection Association,
One Batterymarch Park, Quincy, MA 02269-9101. Additional local build-
ing and regulatory codes may apply in your area. Always check com-
pliance requirements before beginning any installation.
AGENCY PLACEMENT RECOMMENDATIONS
NFPA 72 (National Fire Code)
Smoke Alarms shall be installed in each separate sleeping room, outside
each sleeping area in the immediate vicinity of the bedrooms and on
each additional story of the family living unit, including basements and
excluding crawl spaces and unfinished attics.
In new construction, Alarms shall be so arranged that operation of any
one Alarm shall cause the operation of all Alarms within the dwelling.
Smoke Detection-Are More Smoke Alarms Desirable? The required
number of Smoke Alarms might not provide reliable early warning pro-
tection for those areas separated by a door from the areas protected by
the required Smoke Alarms. For this reason, it is recommended that the
householder consider the use of additional Smoke Alarms for those
areas for increased protection. The additional areas include the base-
ment, bedrooms, dining room, furnace room, utility room, and hallways
not protected by the required Smoke Alarms. The installation of Smoke
Alarms in kitchens, attics (finished or unfinished), or garages is not nor-
mally recommended, as these locations occasionally experience condi-
tions that can result in improper operation.
California State Fire Marshal (CSFM)
Early warning detection is best achieved by the installation of fire detec-
tion equipment in all rooms and areas of the household as follows: A
Smoke Alarm installed in each separate sleeping area (in the vicinity, but
outside bedrooms), and Heat or Smoke Alarms in the living rooms, din-
ing rooms, bedrooms, kitchens, hallways, finished attics, furnace rooms,
closets, utility and storage rooms, basements, and attached garages.
LOCATIONS TO AVOID FOR SMOKE ALARMS
For best performance, it is recommended you AVOID installing
Smoke Alarms in these areas:
Where combustion particles are produced. Combustion particles
form when something burns. Areas to avoid include poorly ventilated
kitchens, garages, and furnace rooms. Keep units at least 20 feet
(6 meters) from the sources of combustion particles (stove, furnace,
water heater, space heater) if possible.
In areas where a 20-foot
(6-meter) distance is not possible in modular, mobile, or smaller
homes, for example it is recommended the Smoke Alarm be placed
as far from these fuel-burning sources as possible. The placement
recommendations are intended to keep these Alarms at a reasonable
distance from a fuel-burning source, and thus reduce unwanted
alarms. Unwanted alarms can occur if a Smoke Alarm is placed
directly next to a fuel-burning source. Ventilate these areas as much
as possible.
In air streams near kitchens. Air currents can draw cooking smoke
into the sensing chamber of a Smoke Alarm near the kitchen.
In very damp, humid or steamy areas, or directly near bathrooms
with showers. Keep units at least 10 feet (3 meters) away from
showers, saunas, dishwashers, etc.
Where the temperatures are regularly below 40˚ F (4˚ C) or above
100˚ F (38˚C), including unheated buildings, outdoor rooms, porches,
or unfinished attics or basements.
In very dusty, dirty, or greasy areas. Do not install a Smoke Alarm
directly over the stove or range. Keep laundry room Smoke Alarms
free of dust or lint.
Near fresh air vents, ceiling fans, or in very drafty areas. Drafts can
blow smoke away from the unit, preventing it from reaching the
sensing chamber.
In insect infested areas. Insects can clog openings to the sensing
chamber and cause unwanted alarms.
Less than 12 inches (305mm) away from fluorescent lights. Electrical
noise can interfere with the sensor.
In dead air spaces. Dead air spaces may prevent smoke from
reaching the Smoke Alarm.
Avoiding Dead Air Spaces
Dead air spaces may prevent smoke from reaching the Smoke Alarm.
To avoid dead air spaces, follow the installation recommendations
below.
On ceilings, install Smoke Alarms as close to the center of the ceiling
as possible. If this is not possible, install the Smoke Alarm at least 4
inches (102 mm) from the wall or corner.
For wall mounting (if allowed by building codes), the top edge of
Smoke Alarms should be placed between 4 and 12 inches (102 and 305
mm) from the wall/ceiling line, below typical dead air spaces.
On a peaked, gabled, or cathedral ceiling, install the first Smoke
Alarm within 3 feet (0.9 meters) of the peak of the ceiling, measured hor-
izontally. Additional Smoke Alarms may be required depending on the
length, angle, etc. of the ceiling's slope. Refer to NFPA 72 for details on
requirements for sloped or peaked ceilings.
5
ABOUT SMOKE ALARMS
Battery (DC) operated Smoke Alarms: Provide protection even when
electricity fails, provided the batteries are fresh and correctly installed.
Units are easy to install, and do not require professional installation.
AC powered Smoke Alarms: Can be interconnected so if one unit
senses smoke, all units alarm. They do not operate if electricity fails.
AC with battery (DC) back-up: will operate if electricity fails, provided
the batteries are fresh and correctly installed. AC and AC/DC units must
be installed by a qualified electrician.
Smoke Alarms for Solar or Wind Energy users and battery backup
power systems: AC powered Smoke Alarms should only be operated
with true or pure sine wave inverters. Operating this Smoke Alarm with
most battery-powered UPS (uninterruptible power supply) products or
square wave or quasi sine wave inverters will damage the Alarm.
If you are not sure about your inverter or UPS type, please consult with
the manufacturer to verify.
Smoke Alarms for the hearing impaired: Special purpose Smoke
Alarms should be installed for the hearing impaired. They include a visu-
al alarm and an audible alarm horn, and meet the requirements of the
Americans With Disabilities Act. Can be interconnected so if one unit
senses smoke, all units alarm.
All these Smoke Alarms are designed to provide early warning of fires if
located, installed and cared for as described in the users manual, and if
smoke reaches them. If you are unsure which type of Smoke Alarm to
install, refer to Chapter 2 of the National Fire Protection Association
(NFPA) Standard 72 (National Fire Alarm Code) and NFPA 101 (Life
Safety Code). National Fire Protection Association, One Batterymarch
Park, Quincy, MA 02269-9101. Local building codes may also require
specific units in new construction or in different areas of the home.
SPECIAL COMPLIANCE CONSIDERATIONS
This Smoke Alarm alone is not a suitable substitute for complete fire
detection systems in places housing many peoplelike apartment
buildings, condominiums, hotels, motels, dormitories, hospitals, long-
term health care facilities, nursing homes, day care facilities, or group
homes of any kindeven if they were once single-family homes. It is not
a suitable substitute for complete fire detection systems in warehouses,
industrial facilities, commercial buildings, and special-purpose non-resi-
dential buildings which require special fire detection and alarm systems.
Depending on the building codes in your area, this Smoke Alarm may be
used to provide additional protection in these facilities.
The following information applies to all four building types below:
In new construction, most building codes require the use of AC or
AC/DC powered Smoke Alarms only. In existing construction, AC,
AC/DC, or DC powered Smoke Alarms can be used as specified by
local building codes. Refer to NFPA 101 (Life Safety Code) or NFPA 72
(National Fire Alarm Code), local building codes, or consult your Fire
Department for detailed fire protection requirements in buildings not
defined as households.
1. Single-Family Residence:
Single family home, townhouse. It is recommended Smoke Alarms be
installed on every level of the home, in every bedroom, and in each bed-
room hallway.
2. Multi-Family or Mixed Occupant Residence:
Apartment building, condominium. This Smoke Alarm is suitable for use
in individual apartments or condos, provided a primary fire detection
system already exists to meet fire detection requirements in common
areas like lobbies, hallways, or porches. Using this Smoke Alarm in
common areas may not provide sufficient warning to all residents or
meet local fire protection ordinances/regulations.
3. Institutions:
Hospitals, day care facilities, long-term health care facilities. This Smoke
Alarm is suitable for use in individual patient sleeping/resident rooms,
provided a primary fire detection system already exists to meet fire
detection requirements in common areas like lobbies, hallways, or
porches. Using this Smoke Alarm in common areas may not provide
sufficient warning to all residents or meet local fire protection ordi-
nances/regulations.
4. Hotels and Motels:
Also boarding houses and dormitories. This Smoke Alarm is suitable for
use inside individual sleeping/resident rooms, provided a primary fire
detection system already exists to meet fire detection requirements in
common areas like lobbies, hallways, or porches. Using this Smoke
Alarm in common areas may not provide sufficient warning to all resi-
dents or meet local fire protection ordinances/regulations.
First Alert®is a registered trademark of the First Alert Trust.
6
Printed in Mexico M08-0020-002 J1 07/04
LIMITATIONS OF SMOKE ALARMS
Smoke Alarms have played a key role in reducing deaths resulting from
home fires worldwide. However, like any warning device, Smoke Alarms
can only work if they are properly located, installed, and maintained, and
if smoke reaches them. They are not foolproof.
Smoke alarms may not waken all individuals. Practice the escape
plan at least twice a year, making sure that everyone is involved from
kids to grandparents. Allow children to master fire escape planning and
practice before holding a fire drill at night when they are sleeping. If
children or others do not readily waken to the sound of the Smoke
Alarm, or if there are infants or family members with mobility limitations,
make sure that someone is assigned to assist them in fire drill and in the
event of an emergency. It is recommended that you hold a fire drill while
family members are sleeping in order to determine their response to the
sound of the Smoke Alarm while sleeping and to determine whether
they may need assistance in the event of an emergency.
Smoke Alarms cannot work without power. Battery operated units
cannot work if the batteries are missing, disconnected or dead, if the
wrong type of batteries are used, or if the batteries are not installed cor-
rectly. AC units cannot work if the AC power is cut off for any reason
(open fuse or circuit breaker, failure along a power line or at a power sta-
tion, electrical fire that burns the electrical wires, etc.). If you are con-
cerned about the limitations of battery or AC power, install both types of
units.
Smoke Alarms cannot detect fires if the smoke does not reach
them. Smoke from fires in chimneys or walls, on roofs, or on the other
side of closed doors may not reach the sensing chamber and set off the
alarm. That is why one unit should be installed inside each bedroom or
sleeping areaespecially if bedroom or sleeping area doors are closed
at nightand in the hallway between them.
Smoke Alarms may not detect fire on another floor or area of the
home. For example, a stand-alone unit on the second floor may not
detect smoke from a basement fire until the fire spreads. This may not
give you enough time to escape safely. That is why recommended mini-
mum protection is at least one unit in every sleeping area, and every
bedroom on every level of your home. Even with a unit on every floor,
stand-alone units may not provide as much protection as interconnect-
ed units, especially if the fire starts in a remote area. Some safety
experts recommend installing interconnected AC powered units with
battery back-up (see About Smoke Alarms) or professional fire detec-
tion systems, so if one unit senses smoke, all units alarm.
Interconnected units may provide earlier warning than stand-alone units
since all units alarm when one detects smoke.
Smoke Alarms may not be heard. Though the alarm horn in this unit
meets or exceeds current standards, it may not be heard if: 1) the unit is
located outside a closed or partially closed door, 2) residents recently
consumed alcohol or drugs, 3) the alarm is drowned out by noise from
stereo, TV, traffic, air conditioner or other appliances, 4) residents are
hearing impaired or sound sleepers. Special purpose units, like those
with visual and audible alarms, should be installed for hearing impaired
residents.
Smoke Alarms may not have time to alarm before the fire itself
causes damage, injury, or death, since smoke from some fires may
not reach the unit immediately. Examples of this include persons
smoking in bed, children playing with matches, or fires caused by
violent explosions resulting from escaping gas.
Smoke Alarms are not foolproof. Like any electronic device, Smoke
Alarms are made of components that can wear out or fail at any time.
You must test the unit weekly to ensure your continued protection.
Smoke Alarms cannot prevent or extinguish fires. They are not a substi-
tute for property or life insurance.
Smoke Alarms have a limited life. The unit should be replaced imme-
diately if it is not operating properly. You should always replace a Smoke
Alarm after 10 years from date of purchase. Write the purchase date on
the space provided on back of unit.