Flir BelgiumBA LTT Wireless MOB System (tag) User Manual 81275 1

Raymarine UK Ltd. Wireless MOB System (tag) 81275 1

Contents

Operation

Download: Flir BelgiumBA LTT Wireless MOB System (tag) User Manual 81275 1
Mirror Download [FCC.gov]Flir BelgiumBA LTT Wireless MOB System (tag) User Manual 81275 1
Document ID668506
Application IDdKXxobfvngFcc6mL8r3uJQ==
Document DescriptionOperation
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize83.42kB (1042754 bits)
Date Submitted2006-06-14 00:00:00
Date Available2006-06-13 00:00:00
Creation Date2006-04-06 14:35:41
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2006-04-06 14:36:03
Document Title81275_1.book
Document CreatorPScript5.dll Version 5.2.2

81275_1.book Page 1 Thursday, April 6, 2006 2:35 PM
LifeTag System
Operating Guide
ra
tc
op
06
04
/0
Document reference: 81275-1
Date: April 2006
81275_1.book Page 2 Thursday, April 6, 2006 2:35 PM
Important Information
WARNING:LifeTag System
The Raymarine LifeTag system is only an aid to crew safety, and must not be
relied upon as the vessel's main crew safety system. It is the responsibility of the
Captain and all crew members to ensure that all safety instructions and
procedures are in place and obeyed in accordance with local requirements.
Failure to operate this system in accordance with the operating instructions may
result in unreliable or reduced system performance.
WARNING:Lithium Batteries
/0
The LifeTag System Tags use non-rechargeable lithium batteries. Do not attempt
to recharge these batteries. Do not incinerate these batteries. Ensure that these
batteries are replaced with a battery of the same type and check local
regulations when disposing of spent batteries. Incorrectly fitting batteries or
using the wrong battery types may result in un-reliable or reduced system
performance.
04
General Care & Safety
06
The operation of some medical electronic devices, such as hearing aids and pacemakers, may be
affected if a LifeTag or LifeTag Base Station is used next to them. Observe the makers
recommendations for such devices.
op
RF Energy
ra
tc
The LifeTag and Lifetag Base Station are low-power radio transceivers. When on, they
intermittently transmit RF energy (radio waves). The LifeTag and LifeTag Base Station are designed
to comply with the limits for RF energy exposure for the general population set by national
authorities and international health agencies, for example BS EN 50371:2002.
Intended Use
The LifeTag and LifeTag Base Station are intended as an aid to safety on leisure vessels and
small workboats.
Waste Electrical and Electronic (WEEE) Directive
The WEEE Directive requires the recycling of waste electrical and electronic equipment.
Whilst the WEEE Directive does not apply to some of Raymarine's products, we support its policy
and ask you to be aware of how to dispose of this product.
The crossed out wheelie bin symbol, illustrated above, and found on our products signifies that this
product should not be disposed of in general waste or landfill.
Please contact your local dealer, national distributor or Raymarine Technical Services for
information on product disposal.
Raymarine and SeaTalk are trademarks of Raymarine plc
© Handbook contents copyright Raymarine plc
81275_1.book Page 1 Thursday, April 6, 2006 2:35 PM
LifeTag System Operating Guide
The LifeTag system
All Tags communicating
with Base Station
Signal lost from any
Tag
Signal lost
No alarm
Alarm sounds
06
04
/0
SeaTalk alarms
If a LifeTag alarm occurs, a SeaTalk alarm will also be initiated if your LifeTag
Base Station is connected to SeaTalk. For details of how SeaTalk alarms are
indicated, refer to the handbooks for your other SeaTalk products .
a Tag is submerged
a Tag is out of range
(typically 30 ft) of
the Base Unit
a Tag button is held
down for 3 to 5 sec
then released
D8883-1
ra
tc
op
The LifeTag system will sound an alarm if . . .
81275_1.book Page 2 Thursday, April 6, 2006 2:35 PM
LifeTag System Operating Guide
Getting started
1. Apply power to Base Station
Base Station
12 V dc
Check that the Alarm 'chirps'
briefly, as power is applied
2. Ensure Tags are Active
Before issuing Tags to crew members, check each Tag to
ensure the LED indicator briefly flashes GREEN once every
10 seconds. This indicates that the Tag is ACTIVE.
06
04
/0
If a Tag is not active,
press and release the
pushbutton to activate
the Tag.
op
If the indicator shows any other indication, check below to determine what to do.
D884-1
ra
tc
3. Issue Tags to crew
Issue Tags to your crew members, then instruct them how to use the LifeTag system.
What to do if an alarm occurs
How to carry Tags
What will initiate an alarm
How to know if a Tag is active
How to know when a battery needs changing
Tag LED indications
Color
Action
Meaning
GREEN
Brief flash once every 10 seconds
Normal operation. The Tag is ready for use.
GREEN & RED
Continuous alternating flashes
Searching for Base Station. Wait for a few seconds. If
normal operation does not start, check that the Base
Station is switched on.
RED
Two flashes once every 10 seconds
Low battery. Replace the battery as described in this guide.
RED
Continuous half-second flashes
every second
Alarm indication. Carry out the Man Overboard procedure.
RED
Continuous brief flashes
Tag is de-registered.
D8985-1
81275_1.book Page 3 Thursday, April 6, 2006 2:35 PM
LifeTag System Operating Guide
Wearing your Tag
Ensure each crew member carries an active Tag at all times
when on board.
or
or
/0
either
on strap provided
on belt
06
04
in pocket
Use extension
if necessary
D8890-1
ra
tc
op
Using the strap
81275_1.book Page 4 Thursday, April 6, 2006 2:35 PM
LifeTag System Operating Guide
What happens when an alarm occurs?
When an alarm is initiated
The Alarm buzzer sounds
Repeat every 1 s
until alarm
canceled
seconds
On active Tags
The indicator flashes RED continuously, half-second flashes
every second
/0
Optional 12 V output
04
When an alarm condition exists, the Base Station optional, switched output provides 12 V as a switching
voltage, for external equipment.
06
Other SeaTalk products
tc
op
If the LifeTag Base Station is connected to a Seatalk system which includes a SeaTalk chartplotter and GPS,
and a LifeTag alarm occurs, a MOB marker will be displayed on the chartplotter at the location of the MOB
event. In addition, the chartplotter and compatible Seatalk instruments (such as ST60+ and ST290 Graphic
instruments) will display a MOB 999 Waypoint Name, and range / bearing or latitiude/longitude to the MOB
location,plus elapsed time since the MOB event.
ra
This occurs only with compatible products on SeaTalk systems. It does NOT occur on other products
connected via NMEA0183.
To cancel a LifeTag alarm
Hold in a Tag button for 5 seconds
Note: This will NOT cancel alarms on associated SeaTalk
products. Refer to relevant product handbooks for details of
how to cancel these alarms.
D8986-1
Tag low battery warning
If the Base Station detects that a Tag battery voltage is low:
The Alarm 'chirps' briefly, every 10 seconds
If this occurs, all users should check their Tags for a
low battery voltage indication (2 RED flashes every
10 seconds). If necessary, replace the battery.
D8987-1
81275_1.book Page 5 Thursday, April 6, 2006 2:35 PM
LifeTag System Operating Guide
Replacing battery
Do NOT use a sharp
object to open a Tag
1. Open the Tag
Do NOT open a Tag in
wet or dirty conditions
2. Remove spent
battery
3. Discard spent battery in
accordance with local
regulations
CR
23
04
/0
5. Replace the Tag back
and snap shut
op
06
4. Taking care not to disturb other internal
components, insert NEW, lithium,
non-rechargeable CR2 3V battery.
Important!
CR
23
ra
tc
Ensure correct
polarity
ap
Sn
D8284-1
Looking after your LifeTag system
Periodically clean the Base Station and Tags, use a clean damp cloth. Do NOT use chemical or
abrasive cleaning agents.
Periocially clean the strap by washing it in fresh water and combing the velcro sections to
remove dirt, fluff etc.
If you are planning not to use the LifeTag system for an extended period (e.g. over winter),
remove the batteries from the Tags, to increase battery life.
Never open a Tag unless you want to remove or replace the battery.
D8920-1
Store all components in a dry location, out of direct sunlight , when not in use.
81275_1.book Page 6 Thursday, April 6, 2006 2:35 PM
LifeTag System Operating Guide
Troubleshooting
Fault
Possible cause
Action
Base Station indicator lit but buzzer
does not sound
Buzzer connection faulty
Cannot register Tag
Tag not powered up
Tag battery discharged
Ensure buzzer is connected to correct
terminals on Base Station
Check that buzzer ‘chirps’ when power
is first switched on
Ensure Tag battery is correctly installed
Replace battery
Base Station indicator does not
light and buzzer does not sound
Base Station not
powered up
Tag not powered up
Tag battery discharged
Tag out of range
Buzzer 'chirps' briefly every 10 s
Tag battery low
Perform site survey as described in
LifeTag System Installation &
Commissioning Guide. If unsatisfactory,
redeploy system components to improve
signal coverage
D8921--1
tc
op
General information
FCC Information
All users to check for low Tag battery
and replace as necessary
06
04
/0
Alarm sounds when there is no
alarm condition
Check Seatalk cable is correctly connected
and apply power to SeaTalk
Check that the SeaTalk system is
operating correctly
Ensure Tag battery is correctly installed
Replace battery
ra
The LifeTag and LifeTag Base Station comply with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) these devices may not cause harmful interference and (2) these devices must accept
interference received, including interference that may cause undesired operation.
Changes or modifications to these devices not expressly approved in writing by Raymarine could violate
compliance with FCC rules and void the user's authority to operate the equipment.
Declaration of Conformity
Raymarine UK Ltd. hereby declares that the LifeTag and LifeTag Base Stationare in compliance with the essential
requirements and other relevant provisions of the R&TTE Directive 1999/5/EC.
The original Declarations of Conformity may be viewed on the relevant product pages at www.raymarine.com.
EU
USA
Industry Canada
R&TTE Directive 1995/5/EC
FCC Part 15
FCC ID: PJ5-LTB (LifeTag Base Station)
RSP100
ID IC4069B-LTB (LifeTag Base Station)
Raymarine UK Ltd,
Quay Point, Northarbour Road
Portsmouth, Hampshire PO6 3TD,
United Kingdom.
Tel: +44 (0) 23 9269 3611
Fax: +44 (0) 23 9269 4642
www.raymarine.com
Raymarine Inc,
21 Manchester Street, Merrimack,
New Hampshire 03054,
USA.
Tel: +1 603.881.5200
Fax: +1 603.864.4756
www.raymarine.com
PJ5-LTT (LifeTag)
IC4069B-LLT (LifeTag)
D9145--1
Approvals

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2006:04:06 14:36:03+01:00
Create Date                     : 2006:04:06 14:35:41+01:00
Metadata Date                   : 2006:04:06 14:36:03+01:00
Format                          : application/pdf
Title                           : 81275_1.book
Document ID                     : uuid:2834c383-d251-4058-bb86-338a6d481726
Instance ID                     : uuid:90e52edb-9a34-4714-a6c3-d0bd99e527c1
Page Count                      : 8
Creator                         : PScript5.dll Version 5.2.2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PJ5-LTT

Navigation menu