Fluke Digital Multimeters
Solutions for every need
ANSI/ISA S82.02
Service
Entrance Meter
Meter
Service
Entrance
Meter
Outbuilding
Outbuilding
Transformer
Underground Service
Underground Service
Service
Entrance
CAT I
Electronic
equipment
Low energy
equipment
with transient
limiting
protection
Any high-
voltage,
low-energy
source derived
from a high-
winding
resistance
transformer
CAT II
Appliances and
portable tools
Outlets and long
branch circuits
Outlets at
more than
10 m (30 ft.)
from CAT III
source
Outlets at
more than
20 m (60 ft.)
from CAT IV
source
CAT IV
Origin of installation: where
low-voltage connection is made
to utility power
Electricity meters, primary
overcurrent protection equipment
Outside and service entrance
Service drop from pole to building
Run between meter and panel
Overhead line to detached
building
Underground line to well pump
CAT III
Equipment in fixed installations:
switchgear and three-phase
motors
Bus and feeder in industrial
plants
Feeders and short branch
circuits
Distribution panel devices
Heavy appliance outlets with
short connections to service
entrance
Large lighting systems
CAT 0 CAT II CAT III CAT IV
How to choose the best
DMM for your job
Choosing the right digital mul-
timeter (DMM) requires thinking
about what you’ll be using it for.
Evaluate your basic measure-
ment needs and job requirements
and then take a look at special
features/functions built into many
multimeters. Think about whether
you need to do basic measure-
ments, or if you need the more
advanced troubleshooting options
offered by special features.
Factors to consider:
Your work environment (voltage
level, types of equipment, types
of measurements, applications)
Specialty features/functions
(capacitance, frequency, tem-
perature, non-contact voltage,
low impedance mode, min-max
record, data logging, trending)
Resolution and accuracy
(6,000, 20,000, or 50,000
count resolution)
Safety
The increased occurrence and
levels of transient overvoltages
in todays power systems have
given rise to more stringent
safety standards for electrical
measurement equipment.
Transients that ride on top of
power sources (mains, feeder
or branch circuits) can trigger
a sequence of events that
may lead to serious injury. Test
equipment must be designed
to protect people working in
this high-voltage, high-current
environment.
Measurement
category
In brief Examples
CAT 0 Electronic (Not directly
connected to mains)
Protected electronic equipment
Equipment connected to (source) circuits in which
measures are taken to limit transient overvoltages to
an appropriately low level
Any high-voltage, low-energy source derived from
a high-winding resistance transformer, such as the
high-voltage section of a copier
CAT II Appliances, PCs,
and TVs
Appliance, portable tools, and other household
and similar loads
Outlet and long branch circuits
Outlets at more than 10 meters (30 feet) from
CAT III source
Outlets more than 20 meters (60 feet) from
CAT IV source
CAT III MC panels, etc. Equipment in fixed installations, such as switchgear
and polyphase motors
Bus and feeder in industrial plants
Feeders and short branch circuits, distribution panel
devices
Lighting systems in larger buildings
Heavy appliance outlets with short connections to
service entrance
CAT IV Three-phase at utility
connection, any
outdoor conductors
Refers to the “origin of installation,” i.e., where low-
voltage connection is made to utility power
Electricity meters, primary overcurrent protection
equipment
Outside and service entrance, service drop from
pole to building, run between meter and panel
Overhead line to detached building, underground
line to well pump
Meters designed for the way you work
Models
Advanced meters Wireless meters General purpose
87 V 289 287 233 3000 FC 179 77 IV
Basic features
Counts 20000 50000 50000 6000 6000 6000 6000
True-rms readings ac ac+dc ac+dc ac ac ac
Basic dc accuracy 0.05
% 0.025
% 0.025
% 0.25
% 0.09
% 0.09
% 0.3
%
Wide bandwidth 20 kHz 100 kHz 100 kHz
Auto/manual ranging /• •/• •/• •/• •/• •/• •/
Digits 4-1/2 4-1/2 4-1/2 3-1/2 3-1/2 3-1/2 3-1/2
ATEX II 2G Eex ia IICT4 safety rating
Zone 1 and Zone 2
Measurements
Voltage ac/dc 1000V 1000V 1000V 1000 V 1000 V 1000 V 1000 V
Current ac/dc 10 A 10 A 10 A 10 A 400 mA 10 A 10 A
Resistance 50 MW500 MW500 MW40 MW50 MW50 MW50 MW
Frequency 200 kHz 1 MHz 1 MHz 50 kHz 100 kHz 100 kHz 100 kHz
Capacitance 10,000 µF 50,000 µF 50,000 µF 10,000 µF 10,000 µF 10,000 µF 10,000 µF
Temperature (+) 1090 °C (+) 1350 °C (+) 1350 °C (+) 400 °C (+) 400 °C
dB 60 dB 60 dB
Conductance 50 nS 50 nS 50 nS
Duty cycle/pulse width /– /• •/
Continuity/diode test •••••••
Motor Drive (ASD) Measurements • •
VoltAlert™, non-contact voltage
detection
VCHEK™
LoZ: low input impedance
Lo Ohms
Microamps •••
Display
Wireless capabilities Removable Wire-
less Display
Remote wireless
readings. Connect
to smart phone.
Dot matrix display • •
Dual display • •
Analog bargraph ••• ••
Backlight Two level Two level Two level ••••
Graphical trend display • •
Diagnostics and data
Min Max recording/with time stamp /– /• •/• •/– /– /– /–
Fast Min Max 250 µs 250 µs 250 µs
Display Hold/Auto (Touch) Hold /• •/• •/• •/• •/• •/• •/
Relative reference •••
Stand alone logging • •
Trend Capture • •
Readings memories 10,000 10,000
USB interface • •
Other features
Automatic selection, ac/dcvolts
Real time clock • •
Overmolded case, integrated holster ••••••
Removable holster
Closed case calibration •••••••
Separate battery/fuse access /– /• •/••••
Completely sealed/ watertight
Automatic power off •••••••
Low battery indication •••••••
Operating temperature range -20 °C, +55 °C -20 °C, +55 °C -20 °C, +55 °C -10 °C, +50 °C -10 °C, +50 °C -10 °C, +50 °C -10 °C, +50 °C
Warranty and electrical safety
Warranty (years) Lifetime Lifetime Lifetime 3 3 Lifetime Lifetime
Input alert •••
Dangerous voltage indication •••••••
IP Rating IP30 IP42 IP42 IP54
EN61010-1 CAT III 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V
EN61010-1 CAT IV 600 V 600 V 600 V 600 V 600 V 600 V 600 V
Models
Compact meters Specialty meters
117 116 115 114 113 28 II 27 II 28IIEX
Basic features
Counts 6000 6000 6000 6000 6000 20000 6000 20000
True-rms readings ac ac ac ac ac ac ac
Basic dc accuracy 0.5
% 0.5
% 0.5
% 0.5
% 0.5
% 0.05
% 0.1
% 0.05
%
Wide bandwidth 20 kHz 30 kHz 20kHz
Auto/manual ranging /• •/• •/• •/• •/• •/• •/• •/
Digits 3-1/2 3-1/2 3-1/2 3-1/2 3-1/2 3-1/2 3-1/2 4-1/2
ATEX II 2G Eex ia IICT4 safety rating
Zone 1 and Zone 2
Measurements
Voltage ac/dc 600 V 600 V 600 V 600 V 600 V 1000 V 1000 V 1000V
Current ac/dc 10 A 600 µA 10 A 10 A 10 A 10 A
Resistance 40 MW40 MW40 MW40 MW60 kW50 MW50 MW50 MW
Frequency 100 kHz 100 kHz 100 kHz 200 kHz 200 kHz 200 kHz
Capacitance 10,000 µF 10,000 µF 10,000 µF 10,000 µF 10,000 µF 10,000 µF 10,000 µF
Temperature (+) 400 °C (+) 1090 °C (+) 1090 °C
dB
Conductance 60 nS 60 nS 60 nS
Duty cycle/pulse width /– /– /–
Continuity/diode test ••••••••
Motor Drive (ASD) Measurements • •
VoltAlert™, non-contact voltage
detection
VCHEK™
LoZ: low input impedance • • • •
Lo Ohms
Microamps • • •
Display
Wireless capabilities
Dot matrix display
Dual display
Analog bargraph ••••••••
Backlight •••••Two level Two level Two level
Graphical trend display
Diagnostics and data
Min Max recording/with time stamp /– /– /– /– /– /– /– /–
Fast Min Max 250 µs 250 µs
Display Hold/Auto (Touch) Hold /– /– /– /– /– /• •/• •/
Relative reference •••
Stand alone logging
Trend Capture
Readings memories
USB interface
Other features
Automatic selection, ac/dcvolts • • • •
Real time clock
Overmolded case, integrated holster
Removable holster ••••••••
Closed case calibration ••••••••
Separate battery/fuse access •••••/·/–
Completely sealed/ watertight •••
Automatic power off ••••••••
Low battery indication ••••••••
Operating temperature range -10 °C, +50 °C -10 °C, +50 °C -10 °C, +50 °C -10 °C, +50 °C -10 °C, +50 °C -40 °C, +55 °C -40 °C, +55 °C -15 °C, +50 °C
Warranty and electrical safety
Warranty (years) 3 3 3 3 3 Lifetime Lifetime 3
Input alert •••
Dangerous voltage indication ••••••••
IP Rating IP42 IP42 IP42 IP42 IP42 IP67 IP67 IP67
EN61010-1 CAT III 600 V 600 V 600 V 600 V 1000 V 1000 V 1000 V
EN61010-1 CAT IV 600 V 600 V 600 V 600 V
Best for Applications Recommended DMM
Advanced meters
Advanced
industrial
troubleshooting,
including
data logging
and graphing
intermittent
problems
Logging: For unattended monitoring of signals over time, to detect intermittent
problems.
289
Graphing: View logged values graphically in the field right on the meter, without a PC.
Working on VSDs: Take accurate voltage, current and frequency measurements on the
output side of the drive at either the drive itself or the motor terminals.
Testing motor windings or contact resistance: Allows testing of resistance up to 50
ohms with one milliohm (0.001 ohm) resolution.
Advanced
electronic
applications,
including
data logging
and graphing
intermittent
problems
Logging: For unattended monitoring of signals over time, characterize device
performance.
287
Graphing: View logged values graphically in the field right on the meter, without a PC.
Monitoring two parameters at the same time: Dual display allows for monitoring of
two selectable parameters.
Performance testing: Testing the frequency response of amplifiers and audio
transmission line.
Industrial
troubleshooting
Working on VSDs: Take accurate voltage, current and frequency measurements on the
output side of the drive at either the drive itself or at the motor terminals.
87V
Industrial troubleshooting: All of the resolution and accuracy you need to solve more
problems on motor drives, in-plant automation, power distribution, and electrome-
chanical equipment.
Checking power quality: Capture glitches and spikes as short as 250 μs. Identify
irregular signals.
Wireless meters
Remote Display
Digital Multimeter
Take measurements in hard to reach places: With its removable display, you have
the flexibility to take measurements in hard to reach places or in areas with restricted
access. You can be in two places at once and reduce the risk of arc flash by separating
yourself from hazardous measurement situations.
233
Work more productively: Now one person can complete a test that would have
required two people using ordinary test tools.
Fluke FC wireless
test tools work
together to help
you troubleshoot
faster
Work faster, safer and easier with FC Wireless Test Tools: The 3000 FC Multimeter
displays the meter measurement, plus readings from up to three wireless modules, connect
to your smart phone to see reading directly on your phone.
3000
FC
Build the system as your needs grow: Start with the multimeter and future proof
your investment.
General purpose meters
Every day use
requiring true-rms,
accurate, rugged
meter
Industrial troubleshooting: Applications requiring exceptional ease-of-use,
ruggedness and reliability.
179
Electrical maintenance and troubleshooting: Variety of commercial electrical
troubleshooting, installation and maintenance.
Temperature measurements: Built-in thermometer conveniently allows you to take
temperature readings without having to carry a separate instrument.
Every day use
requiring average
responding,
accurate, rugged
meter
Industrial troubleshooting: Applications requiring exceptional ease-of-use,
ruggedness and reliability.
77 IV
Electrical maintenance and troubleshooting: Variety of commercial electrical
troubleshooting, installation and maintenance.
Digital Multimeter selection chart
Best for Applications Recommended DMM
Compact meters
Wide variety of electrical
work
Electrical maintenance troubleshooting: When you need to eliminate false or
“ghost” voltages or perform continuity, connection or basic wiring checks.
117
Non-contact voltage detection: Integrated non-contact voltage detection
simplifies many tasks.
HVAC troubleshooting Residential HVAC maintenance: Lower voltage HVAC residential maintenance,
installation and troubleshooting.
116
Temperature and microamp measurements: Troubleshooting problems with
HVAC equipment and flame sensors.
Electronic and field
service applications
Electronic troubleshooting: Troubleshoot a wide variety of measurement
parameters, including frequency and capacitance.
115
Utility applications
involving basic electrical
tests
Revenue meter tests: Involving meter sets and reconnects, capacitor checks,
detection of absence or presence of voltage, and for continuity, connections or
basic wiring checks.
113
Simultaneous voltage and continuity checks: Check LoZ low impedance
function allows users to check voltage and continuity simultaneously.
Specialty meters
Harsh environments
requiring dustproof and
waterproof test equipment
Industrial troubleshooting in indoor and outdoor harsh environments:
Dustproof, waterproof, shockproof multimeter designed to withstand the
toughest environments.
28 II/
27 II
Working on VSDs: Take accurate voltage, current and frequency measurements
on the output side of the drive at either the drive itself or at the motor
terminals. (28 II only)
Industrial troubleshooting
in explosive environments
Safety and compliance: The Fluke 28 II Ex The Model MX57EX TRMS is an
intrinsically safe digital multimeter designed for use in dangerous or explosive
atmospheres. Agency Approvals: IECEx Ex ia IIC T4 Gb, Ex ia IIIC T130 °C Db, I
M1 Ex ia I Ma
87V Ex
Industrial troubleshooting: Completely sealed, IP67 rated case; Withstands
drops up to 10 feet or 3 meters (with holster); Dustproof per IEC60529 IP6x;
Waterproof per IEC60529 IPx7; Meets IEC Overvoltage Electrical Safety
Standard No. 61010-1:2001
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40
2675 200 or Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2008-2014 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 3/2012 3272127C-en
Modification of this document is not permitted
without written permission from Fluke Corporation.
Fluke. Keeping your world up and running.®

Navigation menu