Fortinet Fortianalyzer 4000B Rack And Hardware Install Guide User Manual To The E7a47e2e Fc30 491a 8ab2 8c68f5cd477b
User Manual: Fortinet Fortianalyzer -4000B to the manual
Open the PDF directly: View PDF .
Page Count: 22
Download | |
Open PDF In Browser | View PDF |
FortiAnalyzer-4000B® Rack and Hardware Install Guide Version 4.0 MR2 FortiAnalyzer-4000B Rack and Hardware Install Guide Version 4.0 MR2 28 May 2010 05-420-126194-20100608 © Copyright 2010 Fortinet, Inc. All rights reserved. No part of this publication including text, examples, diagrams or illustrations may be reproduced, transmitted, or translated in any form or by any means, electronic, mechanical, manual, optical or otherwise, for any purpose, without prior written permission of Fortinet, Inc. Trademarks Dynamic Threat Prevention System (DTPS), APSecure, FortiASIC, FortiBIOS, FortiBridge, FortiClient, FortiGate®, FortiGate Unified Threat Management System, FortiGuard®, FortiGuard-Antispam, FortiGuard-Antivirus, FortiGuard-Intrusion, FortiGuard-Web, FortiLog, FortiAnalyzer, FortiManager, Fortinet®, FortiOS, FortiPartner, FortiProtect, FortiReporter, FortiResponse, FortiShield, FortiVoIP, and FortiWiFi are trademarks of Fortinet, Inc. in the United States and/or other countries. The names of actual companies and products mentioned herein may be the trademarks of their respective owners. Regulatory compliance FCC Class A/Class B Part 15 CSA/CUS Caution: Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the Instructions Contents Introduction 1 Registering your Fortinet product. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Customer service and technical support . . . . . . . . . . . . . . . . . . . . . . . . . 1 Fortinet documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Fortinet Tools and Documentation CD . . . . . . . . . . . . . . . . . . . . . . . . 2 Fortinet Knowledge Center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Comments on Fortinet technical documentation . . . . . . . . . . . . . . . . . . 2 Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 IP addresses . . . . . . . . CLI constraints . . . . . . . Notes, Tips and Cautions . Typographical conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rack and Hard Drive Installation Instructions 2 2 2 3 5 Installing Hard Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Removing Hard Drive Trays from the Chassis . . . . . . . . . . . . . . . . . . . . 5 Installing a Hard Drive to the Hard Drive Tray . . . . . . . . . . . . . . . . . . . . 6 Rack Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Overview . . . . . . . . . . . . . . . Unpacking the System . . . . . . . . Preparing for Setup. . . . . . . . . . Choosing a Setup Location. . . . . . Warnings and Precautions!. . . . . . Rack Precautions . . . . . . . . General Server Precautions . . . Rack Mounting Considerations. . . . Ambient Operating Temperature. Reduced Airflow . . . . . . . . . Mechanical Loading . . . . . . . Circuit Overloading. . . . . . . . Reliable Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rack Mounting Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rack Rails Assembly . . . . . . . . . . . Identifying the Inner Rack Rails . . . . . Installing the Inner Rails on the Chassis . Installing the Outer Rails onto a Rack . . Installing the Chassis into a Rack . . . . Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 8 8 8 9 9 9 9 9 9 9 9 10 10 10 10 10 11 12 i Contents ii Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback Introduction Welcome and thank you for selecting Fortinet products for your network protection. Fortinet® ASIC-accelerated multi-threat security systems improve network security, reduce network misuse and abuse, and help you use communications resources more efficiently without compromising the performance of your network. Fortinet systems are ICSAcertified for Antivirus, Firewall, IPSec, SSL-TLS, IPS, Intrusion detection, and AntiSpyware services. Fortinet systems are dedicated, easily managed security devices that deliver a full suite of capabilities including: • Application-level services such as virus protection, intrusion protection, spam filtering, web content filtering, IM, P2P, and VoIP filtering • Network-level services such as firewall, intrusion detection, IPSec and SSL VPN, and traffic shaping • Management services such as user authentication, logging, reporting with FortiAnalyzer, administration profiles, secure web and CLI administrative access, and SNMP. The Fortinet security system uses Fortinet’s Dynamic Threat Prevention System (DTPS™) technology, which leverages breakthroughs in chip design, networking, security and content analysis. The unique ASIC-accelerated architecture analyzes content and behavior in real-time, enabling key applications to be deployed right at the network edge where they are most effective at protecting your networks. This chapter contains the following topics: • Registering your Fortinet product • Customer service and technical support • Fortinet documentation • Conventions Registering your Fortinet product Before you begin, take a moment to register your Fortinet product at the Fortinet Technical Support web site, https://support.fortinet.com. Many Fortinet customer services, such as firmware updates, technical support, and FortiGuard Antivirus and other FortiGuard services, require product registration. For more information, see the Fortinet Knowledge Center article Registration Frequently Asked Questions. Customer service and technical support Fortinet Technical Support provides services designed to make sure that your Fortinet products install quickly, configure easily, and operate reliably in your network. To learn about the technical support services that Fortinet provides, visit the Fortinet Technical Support web site at https://support.fortinet.com. FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback 1 Fortinet documentation Introduction You can dramatically improve the time that it takes to resolve your technical support ticket by providing your configuration file, a network diagram, and other specific information. For a list of required information, see the Fortinet Knowledge Center article What does Fortinet Technical Support require in order to best assist the customer? Fortinet documentation The Fortinet Technical Documentation web site, http://docs.fortinet.com, provides the most up-to-date versions of Fortinet publications, as well as additional technical documentation such as technical notes. In addition to the Fortinet Technical Documentation web site, you can find Fortinet technical documentation on the Fortinet Tools and Documentation CD, and on the Fortinet Knowledge Center. Fortinet Tools and Documentation CD Many Fortinet publications are available on the Fortinet Tools and Documentation CD shipped with your Fortinet product. The documents on this CD are current at shipping time. For current versions of Fortinet documentation, visit the Fortinet Technical Documentation web site, http://docs.fortinet.com. Fortinet Knowledge Center The Fortinet Knowledge Center provides additional Fortinet technical documentation, such as troubleshooting and how-to-articles, examples, FAQs, technical notes, a glossary, and more. Visit the Fortinet Knowledge Center at http://kb.fortinet.com. Comments on Fortinet technical documentation Please send information about any errors or omissions in this or any Fortinet technical document to techdoc@fortinet.com. Conventions Fortinet technical documentation uses the conventions described below. IP addresses To avoid publication of public IP addresses that belong to Fortinet or any other organization, the IP addresses used in Fortinet technical documentation are fictional and follow the documentation guidelines specific to Fortinet. The addresses used are from the private IP address ranges defined in RFC 1918: Address Allocation for Private Internets, available at http://ietf.org/rfc/rfc1918.txt?number-1918. CLI constraints CLI constraints, such as, indicate which data types or string patterns are acceptable input for a given parameter or variable value. CLI constraint conventions are described in the CLI Reference document for each product. Notes, Tips and Cautions Fortinet technical documentation uses the following guidance and styles for notes, tips and cautions. 2 FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback Introduction Conventions Tip: Highlights useful additional information, often tailored to your workplace activity. Note: Also presents useful information, but usually focused on an alternative, optional method, such as a shortcut, to perform a step. Caution: Warns you about commands or procedures that could have unexpected or undesirable results including loss of data or damage to equipment. Typographical conventions Fortinet documentation uses the following typographical conventions: Table 1: Typographical conventions in Fortinet technical documentation Convention Example Button, menu, text box, From Minimum log level, select Notification. field, or check box label CLI input config system dns set primary end CLI output FGT-602803030703 # get system settings comments : (null) opmode : nat Emphasis HTTP connections are not secure and can be intercepted by a third party. File content Firewall Authentication You must authenticate to use this service.
Hyperlink Visit the Fortinet Technical Support web site, https://support.fortinet.com. Keyboard entry Type a name for the remote VPN peer or client, such as Central_Office_1. Navigation Go to VPN > IPSEC > Auto Key (IKE). Publication For details, see the FortiGate Administration Guide. FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback 3 Conventions 4 Introduction FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback Rack and Hard Drive Installation Instructions The FortiAnalyzer-4000B comes with a sliding rail kit. Use the instructions below to install the rails. Caution: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before you begin, review the safety instructions that came with the system. Installing Hard Drives Removing Hard Drive Trays from the Chassis To remove a hard drive tray from the chassis 1 Press the release button on the drive tray. This extends the drive bay handle. 2 Use the handle to pull the drive out of the chassis. Figure 1: Removing the hard drive. 2 1 The drives are mounted in drive trays to simplify their installation and removal from the chassis. These trays also help promote proper airflow for the drive bays. FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback 5 Installing Hard Drives Rack and Hard Drive Installation Instructions Figure 2: Chassis drive tray. Dummy drive Drive tray Note: Except for short periods of time (swapping hard drives), do not operate the server with the hard drives empty. Installing a Hard Drive to the Hard Drive Tray To install a hard drive into the hard drive tray 1 Remove the two screws securing the dummy drive to the drive tray and remove the dummy drive. Place the hard drive tray on a flat surface such as a desk, table or work bench. 6 FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback Rack and Hard Drive Installation Instructions Installing Hard Drives Figure 3: Removing dummy drive from tray. 2 Slide the hard drive into the tray with the printed circuit board side facing down. Figure 4: Installing the hard drive into the tray. SATA hard drive Drive tray 3 Carefully align the mounting holes in both the drive tray and the hard drive. 4 Secure the hard drive to the tray using six screws. FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback 7 Rack Installation Rack and Hard Drive Installation Instructions 5 Replace the drive tray into the chassis. Make sure to close the drive tray handle to lock the drive tray into place. Figure 5: Installing the hard drive in the chassis. Rack Installation Overview This chapter provides a quick setup checklist to get your chassis up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. Unpacking the System You should inspect the box the chassis was shipped in and note if it was damaged in any way. If the chassis itself shows damage you should file a damage claim with the carrier who delivered it. Decide on a suitable location for the rack unit that will hold your chassis. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. You will also need it placed near a grounded power outlet. Be sure to read the Rack and Server Precautions in the next section. Preparing for Setup The box your chassis was shipped in should include two sets of rail assemblies, two rail mounting brackets and the mounting screws you will need to install the system into the rack. Read this section in its entirety before you begin the installation procedure outlined in the sections that follow. Choosing a Setup Location Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches). 8 FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback Rack and Hard Drive Installation Instructions Rack Installation Leave approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing. Warnings and Precautions! This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like). Rack Precautions Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them. In single rack installation, stabilizers should be attached to the rack. In multiple rack installations, the racks should be coupled together. Always make sure the rack is stable before extending a component from the rack. You should extend only one component at a time - extending two or more simultaneously may cause the rack to become unstable. General Server Precautions Review the electrical and general safety precautions that came with the components you are adding to your chassis. Determine the placement of each component in the rack before you install the rails. Install the heaviest server components on the bottom of the rack first, and then work up. Use a regulating uninterruptible power supply (UPS) to protect the server from power surges, voltage spikes and to keep your system operating in case of a power failure. Allow the hot plug hard drives and power supply modules to cool before touching them. Always keep the rack's front door and all panels and components on the servers closed when not servicing to maintain proper cooling. Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra). Reduced Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised. Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading. Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback 9 Rack Mounting Instructions Rack and Hard Drive Installation Instructions Reliable Ground A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.). Rack Mounting Instructions Rack Rails Assembly This section provides information on installing the SC846 chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean that the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using. Note: This rail will fit a rack between 27" and 34.45" deep. Caution: The left and right rails differ from each other. Do not exchange their inner rails. Caution: Keep the ball bearing shuttle locked at the front of the middle rail during installation. Caution: A minimum of two people are required for safe installation of the chassis. To install the unit on the rack 1 Pull the inner rail out of the outer rail until it is fully extended. 10 FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback Rack and Hard Drive Installation Instructions Rack Mounting Instructions Figure 6: Pulling the inner rail out of the outer rail until it is fully extended and pressing the locking tab down. PU LL 2 Press the locking tab down to release the inner rail. See the locking tab in Figure 6. Figure 7: Releasing the inner rail. Outer rail Middle rail Inner rail 3 Place the inner rail firmly against the side of the chassis. Make sure that the hooks straight and aligned with the holes in the inner rail. See Figure 8 (1). 4 Slide the inner rail forward until it clicks into the locked position. See Figure 8 (2) 5 Secure the inner screw (optional). See Figure 8 (3) FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback 11 Rack Mounting Instructions Rack and Hard Drive Installation Instructions Figure 8: Attaching the rails to the chassis. 13 Screw 13 Screw 1 2 Slide the inner rail 6 Press the locking tab and push the middle rail back into the outer rail. Figure 9: Press the locking tab and push the middle rail back into the outer rail. 7 Hang the hooks of the rails on the rack holes and if necessary, secure with screws. 12 FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback Rack and Hard Drive Installation Instructions Rack Mounting Instructions Figure 10: Inserting the hooks on the rails. Optional screws 1 2 8 Repeat Step 7 to mount the four ends, extending the rails as necessary. Figure 11: Installing the rails to the server rack. 9 Pull the middle rail out of the front of the outer rail and make sure that the ball bearing shuttle is locked at the front of the middle rail. 10 Align the inner rails with the middle rails and then push evenly on both sides of the chassis until it clicks into the fully extended position. FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback 13 Rack Mounting Instructions Rack and Hard Drive Installation Instructions Figure 12: Installing the chassis on the rack. Ball bearing shuttle 11 Depress the locking tabs on both sides of the chassis simultaneously and push the chassis all the way into the rear of the rack. 12 If additional security is required, secure the chassis handles to the front of the rack with two screws (optional). 14 FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback Rack and Hard Drive Installation Instructions Rack Mounting Instructions Figure 13: Optional screws to secure chassis to rack. Screw Screw FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback 15 Rack Mounting Instructions 16 Rack and Hard Drive Installation Instructions FortiAnalyzer-4000B Version 4.0 MR2 Rack and Hardware Install Guide 05-420-126194-20100608 http://docs.fortinet.com/ • Feedback www.fortinet.com www.fortinet.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Fortinet Technical Documentation Create Date : 2010:06:29 11:35:08Z Modify Date : 2010:06:29 13:53:37-07:00 Subject : FortiAnalyzer-4000B XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Creator Tool : FrameMaker 8.0 Metadata Date : 2010:06:29 13:53:37-07:00 Producer : Acrobat Distiller 9.2.0 (Windows) Format : application/pdf Title : FortiAnalyzer-4000B Rack and Hardware Install Guide Creator : Fortinet Technical Documentation Description : FortiAnalyzer-4000B Document ID : uuid:96278efb-22fb-499c-95eb-519208bcba15 Instance ID : uuid:b6408f1d-7ace-4ef2-886c-991f5b96e24e Page Mode : UseOutlines Page Count : 22 Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools