SERVICE DATA SHEET

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
CONTROL SETTING
Type A with Run / Start Capacitor

65°F (18°C) Ambient

90°F (32°C) Ambient

90 to 100%

100%

-5° to 2°F
(-20° to -17°C)

-1° to 3°F
(-18° to -16°C)

34° to 39°F
(1° to 4°C)

34° to 39°F
(1° to 4°C)

-2 to 6 psig
(-14 to 41 kPa)

-2 to 6 psig
(-14 to 41 kPa)

85 to 105 psig
(586 to 724 kPa)

120 to 135 psig
(827 to 931 kPa)

Operating Time
Freezer Temperature
Refrigerator Temperature
Low Side Pressure
High Side Pressure
(last 1/3 cycle)
Wattage (last 1/3 cycle)

30 to 50

50 to 70

Amps (running)

.4 to .8

.7 to .9

Base Voltage

A01544601
ICE & WATER - AUTOMATIC DEFROST

ERROR CODES
Display

DEFROST SPECIFICATIONS
Heater

Cabinet Size:
27’ & 28’ SD, 22’ CD

IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.

	

26.5

39°F
(4°C)

Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.

CONDENSER FAN MOTOR

0.03 Running

F

+ and - / same to deactivate

77

77

٨ and - / Power-on-Reset (POR)

--

SH

Shorted FF Thermistor

Sabbath

Sb

Sb

٧ and - / same to deactivate

Shorted FZ Thermistor

System Diagnostic

No FF or FZ display,
all UI LEDs on.

٨ and ٧/ + to deactivate

UI to Main Control
Board communication
failure; on start up

FFIM Diagnostic

Numerical display of
first test

٨ and ٧ together to activate /
press and hold + to deactivate

UI to Main Control
Board communication
error; after a period
in operation

Notes:
• Always check for pin back-outs, pinched or damaged wires before replacing components.
• Determine whether failure is caused by the component, main control board or wiring.
Contact TID before replacing main control board.
• Refer to Service Manual for additional information.

EF

500

1100 CW
Opposite Shaft

d

Display / Showroom

SY

135°F
(57.2°C)

3.1

Manual Defrost

Open FZ Thermistor

CE

110°F
(43.3°C)

Amps

Open FF Thermistor

--

SY

Cut-out

--

Activate:

115 vac (127 vac max)

Thermostat

Opens at 48°F ( 9°C), Closes at 15° F ( -9°C)

Heater Voltage

115 vac

Deactivate:

52C

LINE

NEUTRAL

POWER

MOTOR

63C

P-4

THERMOSTAT
NO

BLU

BLK

C

MOLD HEATER
165 WATTS

NO

GRN / YEL

P-1

C

MOLD

MOUNTING
PLATE

ICE MAKER

NC

WATER FILL
SWITCH

RED

NC

C

Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.
Test

To activate test:

NC

SHUTOFF
SWITCH

First Screen

--

All LED lights on UI illuminated.

--

Second Screen

--

All segments on UI temperature displays illuminated.

--

Third Screen

--

Blank UI display, no lights illuminated.

28

Dispenser Paddle

Press disp. paddle

“on” on UI when depressed; “off” when released.

46

Humidity Sensor

Activates automatically

“OP” if open, “SH” if short.
AC Heater System: Displays %RH.
DC Heater System: “HI” – heater should be on.
“Lo” – heater should be off.
%RH is displayed when humidity is between “Lo” and “HI” values;
heater could be on or off.

47

Dispenser
Pocket Heater

Press set

AC Heater System: “--” ; test not available.
DC Heater System: heater on when “on”, off when “off”.

2

Freezer Defrost
Heater

Press set

Freezer defrost heater on when “on”; off when “off”.

3*

FF Light
(Incandescent Models)

Press set

FF lights on when “on”; off when “off”

8

Water Valve
(Dispenser)

Press set

FF doors must be closed.
Be prepared to collect water at dispenser.
Water dispenses when “on”; stops when “off”.

9*

FZ Light
(Incandescent Models)

Press set

FZ lights on when “on”, off when “off”.

10

Auger Motor

Press set

FF door must be closed.
Motor running when “on”; motor stopped when “off”.

11

Cube/Crush
Solenoid

Press set

FF door must be closed. Do not leave solenoid in activated state.
Solenoid activated when “on”; deactivated when “off”.

VCC Condenser Fan

Press set

Fan running when “on”; stopped when “off”.

43

Anticondensation
Heater

Press set

Flip mullion heater and dispenser pocket heater on when “on”;
off when “off”

Test

38*

VCC Compressor

Press set

Compressor running when “on”; stopped when “off”.

13*

FF Light (LED Models)

Press set

FF lights on when “on”; off when “off”.

15

Evaporator Fan

Press set

Stopped when “off”. Listen for speed change from “LO” to “HI”.

20*

FZ Light (LED Models)

Press set

FZ lights on when “on”, off when “off”.

22

Damper

Press set

With inspection mirror, observe damper open when “OP”; closed when “CL”.

23

FF Door

Open/close FF door

“CL” on UI when door closed; “OP” when open.

24

FZ Door

Open/close FZ door

“CL” on UI when door closed; “OP” when open.

26

Ice Maker
Defrost Heater

Activates automatically

Relay is activated automatically. If “CL” is shown, defrost limit switch is
closed and heater should be heating up. If “OP” is shown, defrost limit
switch is open and heater will not activate.

29

FF Thermistor

Activates automatically

UI shows temperature sensed by FF thermistor; pass if within 10°F of
temperature measured with gauge at FF thermistor location.
“OP-” if open; “SH-” if short.

30

FZ Thermistor

Activates automatically

UI shows temperature sensed by FZ thermistor; pass if within 10°F of
temperature measured with gauge at FZ thermistor location.
“OP” if open; “SH” if short.

33

Ambient Thermistor
@ Main Board

Activates automatically

UI shows temperature sensed at main board; pass if within +20°F/-10°F
of temperature measured with gauge at main board location.
“OP” if open; “SH” if short.

34*

Ambient
Thermistor @UI

Activates automatically

UI shows temperature sensed at UI; pass if within +20°F/-10°F of temperature measured with gauge at UI location. “OP” if open; “SH” if short.

39

Evaporator
Thermistor

Activates automatically

UI shows temperature sensed by evaporator thermistor; pass if within 10°F
of temperature measured with gauge at evaporator thermistor location.
“OP” if open; “SH” if short.

45

Ice Maker Mold
Thermistor

Activates automatically

UI shows temperature sensed at ice maker; pass if within +20°F/-10°F of
temperature measured with gauge at ice maker mold. “OP” if open; “SH”
if short.

0-

Firmware Parameters

Press set

Displays digit sequence; record.

2-

Main Board Firmware

Press set

Displays digit sequence; record.

4-

UI Firmware

Press set

Displays digit sequence; record.

Passing Result

To activate test
Activates
automatically

FZ display shows temperature sensed by Ice Maker Thermistor.
“OP” if open; “SH” if short

Press Set

Remove ice tray to collect water into a measuring container to measure water
fill. If collecting water into ice tray, first perform test 63C to empty ice tray.

Evaporator Fan (FFIM)

Press Set

“On” on FZ display when fan activated, “OFF” when deactivated.

Ice Level Sensor

Activates
automatically

Remove ice bucket.
Allow bail arm to drop freely. Pass if no alarm when tray returns to “home” position.
Hold bail arm up. Pass if alarm sounds when tray returns to “home” position.
This test runs continuously until another test is selected.

Twist Tray

Press Set

Remove ice bucket.
FZ display shows “1” and “GOOD”.

YELLOW

P-2

Variable Capacity Compressor (VCC) Diagnostics (select models)
If test 38 fails, diagnose as follows:
→

Check at the connector from the power cord
harness into the inverter board, located in
the machine compartment.
(PUR and WHT wires)

CAUTION

FREEZER ICE MAKER INFORMATION

Water Fill
Adjustment

Water Fill Volume: The water fill adjustment screw will change the fill time. One full turn is equal to
20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill
volume must be checked.

→

Check at Main Control Board
(BLK/WHT and RED/BLK wires)

yes

Identify and repair damaged wires or
poor connections between Main Control
Board and Inverter Board.

Motor
Gear

TU

R

Mounting
Plate
Screws

Mounting
Plate
Screw

Remove inverter box from the
compressor and check resistance
across compressor winding pairs as
shown.

Is resistance across all winding
pairs equal?

→

yes

Check connections from Inverter
Board to Compressor

Are connections from Inverter
Board to Compressor intact?

no

Replace Compressor and
Inverter Board.

Is Main Control Board sending
10-15 VAC and 1-5 VDC to
Inverter Board?

N

Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All
components of ice maker should function to complete the cycle.

→

yes

no

Check voltage supply.
Check and repair power
cord harness wiring and
connections.

(Where Applicable)

Check at Inverter Board on
Compressor
(BLK and RED wires)

Is Inverter Board receiving 10-15
VAC and 1-5 VDC from Main
Control Board?

no

•

All electrical parts and wiring must be shielded from torch flame. DO NOT allow
torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F.
Excessive heat will distort the plastic liner.

→

yes

Is Inverter Board receiving 115 VAC
from power supply?

•

Passing result

--

LT. BLUE

NO

WATER VALVE

RED

Press + for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
Note: Silence alarm.

12

58C

RED

HOLD
SWITCH

ICE MAKER

BLK

THERMAL
CUT-OUT

Deactivate:

Press + for up to 10 sec. FFIM Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
NOTE: Silence alarm.

Water Valve

57C

LT. BLUE

ICE MAKER

BRN

BLK

Press ٨ and ٧ temperature pads for up to 10 sec. simultaneously.
Press + or - to move forward or backward through tests.

Ice Maker Thermistor

55C

ICE MAKER
P-3

Evaporator Fan Failure

FRESH FOOD ICE MAKER DIAGNOSTIC MODE

FREEZER ICE MAKER SPECIFICATIONS
Electrical

FF

OP

CF

Ohms

FZ

Activate/Deactivate
(press for up to 10 sec. simultaneously)

--

SY

Watts

Display

Mode

OP

SH

Cut-out

RPM

FF

Defrost
Thermistor
Termination

Cut-in

Watts

FZ

SPECIAL MODES

Interpretation

Press ٨ and ٧ for up to 10 sec. simultaneously.
Press + to advance through tests.

•
•
•
•

BOTTOM FREEZER - R134a

115 vac (127 vac max)

Thermal Cutout

SYSTEM DIAGNOSTIC MODE
Activate:

no

no

Identify and repair damaged
wires or poor connections
between Inverter Board and
Compressor.
yes

Replace Main Control Board.

VCC Resistance Check
Check resistance between terminals 1 and
2, 2 and 3, 3 and 1.
If all resistances are equal,
compressor is operative.

Replace Inverter Board

IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should
not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing
this appliance.
IMPORTANT

Timing
Gear

If any green grounding wires are removed during servicing, they must be returned to their original position
and properly secured.

1
5
2
4
J3
3
6
9
10

DC SIDE

FLAPPER
MOTOR

BLK

USER
INTERFACE
3
2
1

J4

LED LIGHT WIRING

PIN 3
PIN 4
PIN 5

PIN 3
PIN 4
PIN 5

LH2

RH2

WHT

RED

1
2
J9
3
4

AC SIDE

GND

2

FREEZER
SENSOR

AT1

1
2
3
4

1
2
3
4

WHT/BLU
WHT/BLU
WHT/BRN
WHT/BRN

LED

LED

LED

RG-2

RG-6

WHT/BLU

IM FAN
MOTOR

RG-3

RG-4

LED

LED

WHT/BRN

RG-1

RG-7

WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU
WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU

BLK

M

2

PIN 4

PIN 7

1

PIN 1

PIN 8

GRN/BLU

M

BAIL ARM
SWITCH

4
3
2
1

MB1

2

RED 1 DK. BLU

TWIST
MOTOR

4
3
2
1

GRY/WHT

1

TRAY
SENSOR

REFRIGERATOR LEDS

IM1
PIN 2

PIN 4

PIN 1

PIN 8

PIN 2

PIN 3

PIN 1

PIN 7

PIN 5

PIN 2

PIN 4

PIN 6

PIN 6

PIN 5

PIN 3

PIN 1

IM2

MC2

GRY/BLK
GRY/BLK

GRN/BLU
DK. BLU
WHT
RED
BLU
YEL
GREY
GREY

1
8
2
3
J7
4
7
5
6

COMM.

NEUTRAL

+5V DC

CAB. GROUND

+12V DC

WHT/GRN

4
3
2
1

WHT/RED
WHT/BRN

WHT/GRN
WHT/GRN
WHT/RED
WHT/RED

4
WHT/GRN 3
2
WHT/RED 1

WHT/RED

WHT/BRN
WHT/BLU

WHT/BLU

EVAPORATOR
FAN (DC)

FZ-2

LED

LED

FZ-1

4

PIN 2

1

PIN 1

2

PIN 3

YEL/WHT
RED/WHT
BRN/WHT

MB1

FREEZER LEDS

RED

COMPRESSOR
CONTROL SIGNAL
TYPICAL LED CONNECTOR

BLK

RED/BLK

1

BLK/WHT

2

RL5
RL4

+5V DC

RL8

AT1
12V DC
DAMPER
MOTOR

RED/YEL

RED/YEL
BRN/YEL

PIN 5

BRN/YEL
BLK/YEL
WHT/YEL

BLK/YEL

PIN 3

WHT/YEL

PIN 2

YEL/BLK (COM)
YEL/GRY (N/C)

LH LIGHT
SWITCH
(DOOR OPEN)

PURPLE (N/O)
PURPLE (COM)

1 2 4 6

PIN 5
PIN 8

YEL/PNK

FREEZER DOOR
SWITCH
(DOOR OPEN)

YEL/GRY
YEL/GRY

YEL/PNK
BLK/ORN
BLK

MB1
PIN 4
PIN 5

YEL/PNK
YEL/PNK

RIBBED
(NEUTRAL)

LT. BLU

12 VDC

GRN/YEL

BASE PLATE
GROUND

BLK

7
4

J3

U2 (SSR1)
RL9

+12V DC

RL7

REVERSIBLE 12V DC

6
J3 3
5

YEL/RED

11
12

11
J5
7

12
J5
8

RIGHT DOOR
FLANGE
FLIP MULLION COVER
RIGHT HINGE
GROUND

PIN 2

YEL/BLK

PIN 3

LT.BLU/BLK

PIN 9
PIN 6
PIN 1

LT. BLU
BLK

RED

PIN 1

1

PIN 2

3

RH3

SPLICE

PIN 1

RH1

CONDENSER FAN

PIN 4

LT. BLU/BLK

LT. BLU/WHT

RH3

LH1
LH2

RH2

TAN

DISPENSER
WATER VALVE

LT. BLU

SPLICE

+5V DC

MAIN INLET
WATER VALVE

SPLICE
TAN/YEL

SPLICE
SPLICE
DIODE

YEL/BLU

+5V DC

YEL/BLU

LINE

RL1

+12V DC
+12V DC
GND

1
5
J1 4
J2

FREEZER ICEMAKER
WATER VALVE

PIN 1

BLK

BLK

PIN 3

LT. BLU

PIN 2

BRN

BLK/ORN
YEL/PNK

PIN 4

FREEZER
EVAPORATOR
HEATER

MB2

3

RL6

OUT1A

1

J3 2
J2 2

BROWN/BLUE
BLU/WHT

AUGER MOTOR

ICEMAKER
EVAPORATOR
HEATER

BROWN

PIN 7

PIN 1

BLU/WHT

PIN 3

PIN 8

PIN 2

PUR/BLK

PIN 9

DEFROST
BIMETAL

CUBE/CRUSH
SOLENOID
AUGER
MOTOR

PURPLE

PIN 7

J3 1

BEHIND FRONT
LEFT ROLLER

PIN 5

MC1

OUT2A
RL3

GRN/YEL

COIL COVER
GROUND

OUT1B

OUT2B

YEL/BLU

2

IM1
RL2

FREEZER DOOR
SWITCH
(DOOR OPEN)
4

FREEZER
ICE MAKER
(SEE FZ ICE
MAKER DIAGRAM)

ERF2500++ISO
REFRIGERATOR
CONTROL

YEL/PNK

THERMAL
CUT-OUT

PIN 4

RH1

+5V DC
BOARD-MOUNTED
AMBIENT THERMISTOR

SPLICE

PURPLE (COM)
PURPLE (N/O)
YEL/GRY (N/C)
YEL/BLK (COM)
PURPLE (COM)
PUR/BLK (N/O)
YEL/GRY (N/C)
YEL/BLK (COM)

PIN 4

IM1

LT. BLU

LH LIGHT
SWITCH
(DOOR OPEN)

BOARD VIEW

RH LIGHT
SWITCH
(DOOR OPEN)

J9
J10

+5V DC

2 4
J1
1 3

+5V DC

RL2

1

LH2 & RH2

LH1
4

3

1

1

RL3

BACK VIEW

7

1

1

7

6

MC1
MB1

MB2

3

3

6

3

9

9

3

1

7

7

1

MB2

4

8 8

4

1

5 5

1

2

1

1

2

J8
AMBIENT
TEMP
SENSOR

1
J4

1

1

J7
U2 RL4

RL7

J5

1

1

1

MC2

MC1

MC2

LATCH

CATCH

AT1

RL8

2

1

RL9

RH3
5

5

4

12
J6

J3

AT1, IM1, MB1, & RH1

11
RL5

RL6

9

J11

1 4

RL1

1

9

FLAPPER & SUMP
HEATER

LT. BLU

IM2

3

2
1

LH1

TWIST ICEMAKER
WATER VALVE

FRONT INSIDE
VIEW

IM1

MULLION HEATER

PIN 2
YEL

J2
RH1

2

GRN/YEL

SPLICE

LT. BLU/BLK

PIN 6

DIODE

+12V DC

5
6
J5
3
4

GRN/YEL

MC1

MC1

CABINET
WRAPPER

1
J8
2

1 2 4 6

YEL/BLK (COM)
YEL/GRY (N/C)
PUR/BLK (N/O)
PURPLE (COM)

RH LIGHT
SWITCH
(DOOR OPEN)

RH1

J2 3

+5V DC

1
PIN 6

INLINE CONNECTOR ABBREVIATION KEY
ABBR.
EXPLANATION
AT1 9 PIN CONNECTION AT AIR TOWER
9 PIN CONNECTION IN FRESH
IM1
FOOD ICEMAKER COMPARTMENT
6 PIN CONNECTION IN FRESH
IM2
FOOD ICEMAKER COMPARTMENT
6 PIN CONNECTION AT THE LEFT
LH1
DOOR UPPER HINGE
5 PIN CONNECTION AT THE LEFT
LH2
DOOR UPPER HINGE
9 PIN CONNECTION IN THE MAIN
MB1 BOARD HOUSING BEHIND THE TOE
GRILLE
4 PIN CONNECTION IN THE MAIN
MB2 BOARD HOUSING BEHIND THE TOE
GRILLE
9 PIN CONNECTION IN THE
MC1 MACHINE COMPARTMENT TO THE
LEFT OF THE COMPRESSOR
8 PIN CONNECTION IN THE
MC2 MACHINE COMPARTMENT TO THE
LEFT OF THE COMPRESSOR
9 PIN CONNECTION AT THE RIGHT
RH1
DOOR UPPER HINGE
5 PIN CONNECTION AT THE RIGHT
RH2
DOOR UPPER HINGE
2 PIN CONNECTION AT THE RIGHT
RH3
DOOR UPPER HINGE

3
4
5
6
7
J4
8
9

1
J1 2
3

VARIABLE SPEED
COMPRESSOR/ INV.

CONTROL SIGNAL
RED/BLK
BLK/WHT

PIN 5

+5V DC

NEUTRAL
WHT/GRN

LT. BLU

TAN

RG-5

GRY/WHT

7
8
9
J6
10
11
12

BLK
LT. BLU

SPLICE

YEL

WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU

4
3
2
1

4
3
2
1
WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU

4
3
2
1
WHT/BRN
WHT/BRN
WHT/BLU
WHT/BLU

LED

GRY/YEL

1

FRESH FOOD
SENSOR
LED

GRY/YEL

2

POWER

LT. BLU
BLK

LINE
FREEZER
EVAPORATOR
SENSOR

COMPRESSOR
GROUND

PIN 1

REVERSIBLE
12V

DISPENSER
PADDLE
DISPENSER
LIGHT

PIN 4

+12V DC

6 4 2 1

+12V DC

BASE PLATE
GROUND

FLAPPER
POSITION
SWITCH

6 4 2 1

+12V DC

NON-RIBBED
(LINE)

POWER CORD

IM2

2

4

4

2

3

6 6

3

1

3

3

1

1

4

4

1

LED POWER
BOARD

Wire Diagram A01536801



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2014:05:06 14:37:31-04:00
Metadata Date                   : 2014:05:06 14:37:34-04:00
Modify Date                     : 2014:05:06 14:37:34-04:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:e7a53291-3f11-4116-9c27-0e73f00762fd
Original Document ID            : xmp.did:344914B496C2E011953287C3BB646DCE
Document ID                     : xmp.id:4F2ECB7B4DD5E31192DEFCAA7ACB94C4
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:B3DF33154DD5E31192DEFCAA7ACB94C4
Derived From Document ID        : xmp.did:AF79E0375DD4E31192DEFCAA7ACB94C4
Derived From Original Document ID: xmp.did:344914B496C2E011953287C3BB646DCE
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2014:05:06 14:37:31-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu