Fuji Film 01000006 Flat Panel Detector User Manual 897N120339A Z72N3191A 141015

Fuji Film Corporation Flat Panel Detector 897N120339A Z72N3191A 141015

Contents

(Short-Term Confidential) User Manual 1

Download: Fuji Film 01000006 Flat Panel Detector User Manual 897N120339A Z72N3191A 141015
Mirror Download [FCC.gov]Fuji Film 01000006 Flat Panel Detector User Manual 897N120339A Z72N3191A 141015
Document ID2473601
Application ID0STzFv44PtSUxX6ViWjaJg==
Document Description(Short-Term Confidential) User Manual 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize232.87kB (2910863 bits)
Date Submitted2014-12-15 00:00:00
Date Available2015-06-14 00:00:00
Creation Date2014-11-19 11:48:11
Producing SoftwareAcrobat Distiller 10.1.2 (Windows)
Document Lastmod2014-11-19 11:48:11
Document Title897N120339A_Z72N3191A_141015.pdf
Document CreatorAdobe InDesign CS6 (Windows)
Document Author: 14539

For Safe Operation
DIGITAL RADIOGRAPHY
System
&RQÂżJXUDWLRQ
(Product Overview)
(DR-ID 1200)
Operation Manual
Basic Operation
2nd Edition : October 2014
7URXEOHVKRRWLQJ
Daily Inspection and
Maintenance
Appendix
Maintenance and
Inspection
This Operation Manual describes details on how to operate the FDR D-EVO II and
cautions to be observed when operating it. Please read the Operation Manual
thoroughly before actually operating the FDR D-EVO II along with “DR-ID 300CL
Operation Manual” and other manuals for the related products.
After reading this manual, store it nearby the FDR D-EVO II so that you can see
it whenever necessary.
897N120339A
ii
FDR D-EVO II Operation Manual
897N120339A
Introduction
This Operation Manual includes descriptions of matters necessary when using the FDR D-EVO II ,
such as the equipment overview, operation procedures and precautions to observe, as well as daily
inspections and maintenance.
Accompanying documents were originally drafted in the English language.
Installation may only be conducted by authorized service personal.
Indications for use (for U.S.)
The Wired/Wireless FDR D-EVO IIÀDWSDQHOVHQVRUV\VWHPLVLQWHQGHGWRFDSWXUHIRUGLVSOD\
radiographic images of human anatomy. It is intended for use in general projection radiographic
DSSOLFDWLRQVLQFOXGLQJSHGLDWULFDQGQHRQDWDOH[DPVZKHUHYHUFRQYHQWLRQDOÂżOPVFUHHQRU&5
systems may be used. The FDR D-EVO IILVQRWLQWHQGHGIRUPDPPRJUDSK\ÀXRURVFRS\
tomography, and angiography applications.
Intended use (for European Union and other countries.)
The FDR D-EVO IIÀDWSDQHOGHWHFWRUV\VWHPLVLQWHQGHGWRFDSWXUHIRUGLVSOD\UDGLRJUDSKLFLPDJHV
of human anatomy. It is intended for use in general projection radiographic applications wherever
FRQYHQWLRQDOÂżOPVFUHHQRU&5V\VWHPVPD\EHXVHG
Note : The above statements were determined by applicable medical device regulations which vary
throughout the world. These statements are subject to revision when additional clearance or
approval is obtained.
CAUTIONS
1. No part or all of this manual may be reproduced in any form without prior permission.
7KHLQIRUPDWLRQFRQWDLQHGLQWKLVPDQXDOPD\EHVXEMHFWWRFKDQJHZLWKRXWSULRUQRWLFH
)8-,),/0&RUSRUDWLRQVKDOOQRWEHOLDEOHIRUPDOIXQFWLRQVDQGGDPDJHVUHVXOWLQJIURP
LQVWDOODWLRQUHORFDWLRQUHPRGHOLQJPDLQWHQDQFHDQGUHSDLUSHUIRUPHGE\RWKHUWKDQGHDOHUV
VSHFLÂżHGE\)8-,),/0&RUSRUDWLRQ
)8-,),/0&RUSRUDWLRQVKDOOQRWEHOLDEOHIRUPDOIXQFWLRQVDQGGDPDJHVRI)8-,),/0
Corporation products due to products of other manufacturers not supplied by FUJIFILM
Corporation.
)8-,),/0&RUSRUDWLRQVKDOOQRWEHOLDEOHIRUPDOIXQFWLRQVDQGGDPDJHVUHVXOWLQJIURP
UHPRGHOLQJPDLQWHQDQFHDQGUHSDLUXVLQJUHSDLUSDUWVRWKHUWKDQWKRVHVSHFLÂżHGE\
FUJIFILM Corporation.
)8-,),/0&RUSRUDWLRQVKDOOQRWEHOLDEOHIRUPDOIXQFWLRQVDQGGDPDJHVUHVXOWLQJIURP
QHJOLJHQFHRISUHFDXWLRQVDQGRSHUDWLQJPHWKRGVFRQWDLQHGLQWKLVPDQXDO
)8-,),/0&RUSRUDWLRQVKDOOQRWEHOLDEOHIRUPDOIXQFWLRQVDQGGDPDJHVUHVXOWLQJIURPXVH
XQGHUHQYLURQPHQWFRQGLWLRQVRXWVLGHWKHUDQJHRIXVLQJFRQGLWLRQVIRUWKLVSURGXFWVXFKDV
power supply, installation environment, etc. contained in this manual.
)8-,),/0&RUSRUDWLRQVKDOOQRWEHOLDEOHIRUPDOIXQFWLRQVDQGGDPDJHVUHVXOWLQJIURP
QDWXUDOGLVDVWHUVVXFKDV¿UHVHDUWKTXDNHVÀRRGVOLJKWQLQJHWF
7KLVV\VWHPLVFODVVLÂżHGDVDPHGLFDOGHYLFHXQGHU(&'LUHFWLYH((&
Caution : Rx Only in the United States (Federal law restricts this device to sale by or on the order
of a physician.)
FDR D-EVO II Operation Manual
897N120339A
iii
Open-Source Software Contained in This Product
This product contains third party’s software that is made available as open source software or free
software.
7KLVVRIWZDUHLVSURYLGHG³DVLV´ZLWKQRZDUUDQW\RIDQ\NLQGDVWRLWVPHUFKDQWDELOLW\RU¿WQHVVIRU
any particular purpose.
For the information on open source software contained in this product, please see the attached DVD.
Source codes for certain type of open source software used in this product are available at delivery cost.
If you would like to receive such source codes, please contact FUJIFILM dealer or the service
representatives at the agency from which you purchased this product. (Please be noted that any
inquiries concerning the contents of source codes should be directed to original licensors of open
source software.)
Note :)8-,),/0KDVVXFFHVVIXOO\SHUIRUPHGYHULÂżFDWLRQDQGYDOLGDWLRQWHVWLQJRQDOOWKLUGSDUW\
VRIWZDUHDQGKDVFRQÂżUPHGLWVVXLWDELOLW\WREHXVHGLQWKLVV\VWHP
7UDGHPDUNV
All company names and product names described in this manual are the trademarks or registered
trademarks of FUJIFILM Corporation or their respective holders.
Windows is the registered trademark of US Microsoft Corporation in the U.S.A. and other countries.
SDHC Logo is a trademark of SD-3C, LLC.
Copyright Š 2014 FUJIFILM Corporation. All rights reserved.
iv
FDR D-EVO II Operation Manual
897N120339A
FDR D-EVO II System Operation Manuals
DIGITAL RADIOGRAPHY
FDR D-EVO II (DR-ID 1200) Operation Manual
DR-ID 1200PU Operation Manual
DR-ID 1200DU Operation Manual
DR-ID 300CL Operation Manual
The DR-ID 1200MC runs on a commercially available personal computer. However, operations
are not required to use the FDR D-EVO II. For operations of a commercially available personal
computer, see the operation manual provided by the manufacturer.
Manage and store all the Operation Manuals of the devices constituting the system together as a set.
FDR D-EVO II Operation Manual
897N120339A
(When the optional access point is used)
DIGITAL RADIOGRAPHY DR-ID 1200
PANEL UNIT DR-ID 1200PU
DOCKING UNIT DR-ID 1200DU
Flat panel
sensor
Flat panel
sensor
Power supply unit DR-ID 1200MP
Docking stand DR-ID 1200DS
Image processing unit DR-ID 300CL*1, *3
Access point
Battery charger
Hub
Image processing unit of other
digital radiography system DR-ID 300CL
(When an access point installed in the hospital is used)
DIGITAL RADIOGRAPHY DR-ID 1200
PANEL UNIT DR-ID 1200PU
Flat panel
sensor
Power supply unit DR-ID 1200MP
DOCKING UNIT DR-ID 1200DU
Flat panel
sensor
Docking stand DR-ID 1200DS
Image processing unit DR-ID 300CL*3
Battery charger
Control cabinet DR-ID 1200MC*2
Access point
Hub
vi
FDR D-EVO II Operation Manual
897N120339A
Image processing unit of other
digital radiography system DR-ID 300CL
7KHUHDUHIRXUW\SHVRIÀDWSDQHOVHQVRUV'5,'6('5,'6('5,'6(DQG
DR-ID 1212SE (wireless/wired communication mode). Although the contents of this manual are
GHVFULEHGE\WDNLQJWKHH[DPSOHRI'5,'6(WKHVDPHFDQDOVREHDSSOLHGWRRWKHUÀDWSDQHO
VHQVRUV:LWKUHJDUGWRWKHGHVFULSWLRQVSHFL¿FWRDFHUWDLQW\SHRIÀDWSDQHOVHQVRUWKHSURGXFW
name is given in the description.
The panel unit (DR-ID 1200PU) and the docking unit (DR-ID 1200DU) can be used simultaneously.
Up to two power supply units (DR-ID 1200MP) and up to three docking stands (DR-ID 1200DS) can
be used.
To use the digital radiography (DR-ID 1200), either one power supply unit or docking stand is
necessary.
*1 The software for the control cabinet is installed on the image processing unit (DR-ID 300CL).
'HSHQGLQJRQWKHFRQÂżJXUDWLRQWKHFRQWUROFDELQHW '5,'0& PD\QRWEHLQFOXGHGLQWKH
system.
If not included, the software for the control cabinet can be installed on the image processing unit
(DR-ID 300CL).
 )
 RUGHWDLOVSHFLÂżFDWLRQRILPDJHSURFHVVLQJXQLWSOHDVHUHIHUWRÂł'5,'&/2SHUDWLRQ
Manual”.
*3 When the image processing unit (DR-ID 300CL) is used in patient environment, run the notebook
computer on battery power.
FDR D-EVO II Operation Manual
897N120339A
vii
viii
FDR D-EVO II Operation Manual
897N120339A
Contents at a Glance
Chapter
Chapter
Chapter
Chapter
Chapter
Appendix
For Safe Operation
This chapter presents Warnings and Cautions we wish you to observe for safe
operation of the FDR D-EVO II.
6\VWHP&RQÂżJXUDWLRQ 3URGXFW2YHUYLHZ
This chapter gives the various unit names and describes their functions and
features of the FDR D-EVO II.
Basic Operation
This chapter describes start-up, shut-down and other basic operations of the
FDR D-EVO II.
Troubleshooting
This chapter describes how to troubleshoot in the event of an error on the FDR
D-EVO II, and provides explanations about a list of error messages each of
which appears when an error occurs.
Daily Inspection and Maintenance
This chapter describes daily care and maintenance we wish you to perform so
that you can use the FDR D-EVO II optimally.
$SSHQGL[$ 6SHFLÂżFDWLRQV
Appendix Z Precautions for Exposure
Appendix O Use of Optional Items
Maintenance and Inspection
Radio frequency (RF) compliance information
FDR D-EVO II Operation Manual
897N120339A
ix
How to Read This Manual
%DVLFSDJHOD\RXW
3OHDVHKDYHDJRRGJUDVSRIWKHEDVLFSDJHFRQÂżJXUDWLRQRIWKLV2SHUDWLRQ0DQXDODVLOOXVWUDWHG
EHORZIRU\RXWRXVHLWPRUHHIÂżFLHQWO\
Section title
Lead
Shows the title of an operation procedure
described in the section.
Describes information we wish you to know in
advance of your operating the system or information
that may help you to operate it.
3.2 Starting Up and Shutting Down the System
This section explains how to start up and shut down the system. Operations are required on the power
VXSSO\XQLWGRFNLQJVWDQGÀDWSDQHOVHQVRUDQGLPDJHSURFHVVLQJXQLW
The image processing unit in this section is only an example. For details on the image processing unit being used,
see the Operation Manual provided with the personal computer.
Index
3.2.1 Starting Up the System
Operation procedure
Describes an operation
procedure according to
sequential numbers.
(When the DR-ID 1200PU is used)
Make sure that the power cable is connected to the image processing unit.
1
Basic Operation
2
:KHQWKHÀDWSDQHOVHQVRULVXVHGLQZLUHOHVVFRPPXQLFDWLRQPRGHLQVWDOOWKHIXOO\FKDUJHG
EDWWHU\SDFNWRWKHÀDWSDQHOVHQVRU
:KHQLWLVXVHGLQZLUHGFRPPXQLFDWLRQPRGHFRQQHFWWKHÀDWSDQHOVHQVRUDQGWKHSRZHU
VXSSO\XQLWXVLQJWKH6(FDEOH
3UHVVWKH21VLGHRIWKHPDLQVZLWFKRIWKHSRZHUVXSSO\XQLW
Make sure that the power status LED is lit in blue.
3
A caption that
facilitates you to
open a desired
[Chapter] quickly.
:KHQWKHRSWLRQDODFFHVVSRLQWLVXVHGFRQQHFWWKHDFFHVVSRLQWWRWKHLPDJHSURFHVVLQJXQLW
CAUTIONS
8VHWKHRSWLRQDODFFHVVSRLQWE\FRQQHFWLQJLWWRWKHSUHVHWLPDJHSURFHVVLQJXQLWDQGWRWKH86%
FRQQHFWRU'RQRWXVHWKHRSWLRQDODFFHVVSRLQWE\FRQQHFWLQJLWWRRWKHULPDJHSURFHVVLQJXQLWDQG
RU86%FRQQHFWRU
4
3UHVVWKH21VLGHRIWKHPDLQVZLWFKRIWKHSRZHUVXSSO\XQLW
7KHLQLWLDOL]DWLRQSURFHVVVWDUWV
• All cables should be connected properly.
• No media should be inserted into the disk drive of image processing unit.
If the control cabinet is included in the system, the control cabinet starts up automatically.
CAUTIONS
,IWKHSRZHUVWDWXV/('RIWKHFRQWUROFDELQHWGRHVQRWFRPHRQDIWHUWXUQLQJRQWKHLPDJH
SURFHVVLQJXQLWWXUQRQWKHFRQWUROFDELQHW
FDR D-EVO II Operation Manual
897N120339A
3-9
3DJHQXPEHU
Displayed in conjunction with the
chapter number.
FDR D-EVO II Operation Manual
897N120339A
0DUNV
Information items to be observed when you are operating this system and the supplementary
remarks are described in this manual with the respective marks.
For the safe system operation, be sure to observe Warning/Caution.
WARNING
Indicates hazardous situations that may lead to serious injuries or
even death if the precaution is not or cannot be followed.
CAUTIONS
Indicates hazardous situations that may lead to mild or moderate
injury or physical damages if the caution is not or cannot be
followed.
Indicates procedures requiring special attention, instructions that
must be followed, supplementary explanations, etc.
HINT
Shows an item helpful for further effective system operation.
Shows a more detailed operation method or an item that
describes additional information.
Expressions
Messages appear on the display panel and the buttons are shown as below.
Ɣ %XWWRQV H[DPSOH
------------------------------
Select
The button to operate is shown.
FDR D-EVO II Operation Manual
897N120339A
xi
Contents
Introduction ...........................................................................................................................iii
FDR D-EVO II System Operation Manuals .......................................................................... v
Contents at a Glance ............................................................................................................ix
How to Read This Manual .................................................................................................... x
Chapter 1 For Safe Operation
1.1
Precautions Before Operating This Equipment ....................................................... 1-1
1.2
Precautions to be Observed When Using the Electric Medical Equipment ............. 1-2
1.3
Safety ...................................................................................................................... 1-3
1.4
Electromagnetic Compatibility (EMC).................................................................... 1-12
1.4.1
1.5
Precautions in Using the FDR D-EVO II .............................................................. 1-17
1.5.1
1.5.2
1.5.3
1.5.4
1.5.5
1.5.6
1.5.7
1.5.8
1.6
Handling.................................................................................................................1-17
Before Exposure ....................................................................................................1-18
During Exposure ....................................................................................................1-19
During Cleaning .....................................................................................................1-20
Storage ..................................................................................................................1-20
Precautions Related to the Load Applied to the Flat Panel Sensor .......................1-21
Radio Waves .........................................................................................................1-22
Battery Pack Status Indicator ................................................................................1-23
Locations of Labels and Signs .............................................................................. 1-24
1.6.1
1.6.2
1.6.3
1.6.4
1.6.4
1.6.5
1.7
DR-ID 1200 ...................................................................................................................1-12
Locations of Labels ................................................................................................1-24
DR-ID 1200 ............................................................................................................1-26
DR-ID 1200PU .......................................................................................................1-27
DR-ID 1200DU.......................................................................................................1-27
Safety and Other Symbols .....................................................................................1-28
Symboles de sĂŠcuritĂŠ et autres .............................................................................1-29
Installation Conditions ........................................................................................... 1-30

1.7.2
1.7.3
'HÂżQLWLRQRI3DWLHQW(QYLURQPHQW ..........................................................................1-30
Installation Precautions..........................................................................................1-31
Precautions for Installing the Access Point (Optional) ...........................................1-31
Chapter 2 6\VWHP&RQÂżJXUDWLRQ 3URGXFW2YHUYLHZ
2.1
FDR D-EVO II .................................................................................................................................................. 2-1

2.1.2
2.2
Unit Names and the Functions ................................................................................ 2-4
2.2.1
xii
6\VWHP&RQÂżJXUDWLRQ ..............................................................................................2-1
Features of the FDR D-EVO II .................................................................................................... 2-3
DR-ID 1200 ..............................................................................................................2-4

,PDJH3URFHVVLQJ8QLW'LVSOD\&RQÂżJXUDWLRQ ......................................................... 2-9
2.4
Routine Operation Diagram................................................................................... 2-13

:LUHOHVV6SHFLÂżFDWLRQV ......................................................................................... 2-14
FDR D-EVO II Operation Manual
897N120339A
Chapter 3 Basic Operation
3.1
Preparing the Flat Panel Sensor ............................................................................. 3-1
3.1.1
3.1.2
3.1.3
3.1.4
Type of Flat Panel Sensor .......................................................................................3-1
Number of the Connectable Flat Panel Sensors .....................................................3-1
Connecting/Disconnecting the Flat Panel Sensor Connector ..................................3-1
Inserting/Removing the Flat Panel Sensor into/
from the Radiographic Examination Stand ..............................................................3-2
3.1.5 Changing the Direction of the Flat Panel Sensor Connector ...................................3-4
3.1.6 Charging the Battery Pack for the Flat Panel Sensor ..............................................3-5
3.1.7 Charging the Image Processing Unit ..............................................................................3-6
3.1.8 Installing/Removing the Battery Pack for the Flat Panel Sensor .............................3-6
3.1.10 Attaching the Flat Panel Sensor to the Docking Stand ............................................3-8
3.2
Starting Up and Shutting Down the System ...............................................................................3-9
3.2.1
3.2.2
3.3
Routine Operations ....................................................................................................3-13
Step 1
Step 2
Step 3
3.4
Starting Up the System ............................................................................................3-9
Shutting Down the System .................................................................................... 3-11
Entering the Patient Information .............................................................................3-14
Selecting the Anatomical Region and Exposure/Study Menu.................................3-15
X-ray Exposure .......................................................................................................3-17
[1] Positioning the patient ......................................................................................3-17
[2] X-ray exposure/Image displaying .....................................................................3-18
[3] Sleep mode.......................................................................................................3-19
[4] Extended Image Readout .................................................................................3-19
How to Use Memory Exposure Mode........................................................................3-20
3.4.1
3.4.2
3.4.3
3.4.4
How to Start up and Use Memory Exposure Mode ...............................................3-20
How to Load Images ..............................................................................................3-21
List of Error Codes .................................................................................................3-22
How to Terminate Memory Exposure Mode...........................................................3-22
&KDSWHU7URXEOHVKRRWLQJ
4.1
When a Message Appears on the Image Processing Unit .................................................... 4-1
[1] If a warning dialog box appears ......................................................................................4-1
[2] If the message dialogue box MD11001 appears ..............................................................4-1
[3] If an exposed image cannot be acquired .........................................................................4-2
[4] If the dialog box containing the error message numbered 13048 appears ......................4-3
[5] If “Unusable due to error.” appears on the image processing unit................................................4-3
[6] If any other message dialogue box appears ....................................................................4-4
4.2
How to Cope with an Error... ................................................................................... 4-5
[1] When the image processing unit hangs up… ..................................................................4-5
[2] When the image processing unit is turned off due to an electrical outage .......................4-5
[3] If a hard disk of the image processing unit is damaged ...................................................4-6
[4] If a white image is displayed after an exposure ...............................................................4-6
[5] Precautions for operation when the device status is “Initializing” or
“Changing FPD” in the image processing unit’s “Output Device Status window” ............4-6
>@,IWKHÀDWSDQHOVHQVRUFDQQRWEHXVHGLQZLUHOHVVFRPPXQLFDWLRQPRGH ......................4-6
[7] If an error occurs on an output destination device ...........................................................4-7
Chapter 5 Daily Inspection and Maintenance
5.1
Daily User Inspection and Maintenance .................................................................... 5-1
5.1.1
5.1.2
Daily Inspection (DR-ID 1200) .................................................................................5-1
Periodical Inspection................................................................................................5-2
FDR D-EVO II Operation Manual
897N120339A
xiii
$SSHQGL[$6SHFLÂżFDWLRQV
$
6SHFLÂżFDWLRQV ..........................................................................................................A-1
A.1.1
A.1.2
A.1.3
A.1.4
A.1.5
A.2
External View and Weight .......................................................................................A-5
A.2.1
A.3
Processing Capacity (DR-ID 1200)......................................................................... A-1
Image Output (DR-ID 1200).................................................................................... A-1
Reduced Equivalent................................................................................................ A-2
Power Supply Conditions........................................................................................ A-3
Environmental Conditions ....................................................................................... A-3
DR-ID 1200 ............................................................................................................. A-5
Characteristics.........................................................................................................A-9
Appendix Z Precautions for Exposure
Z.1
Precautions for Exposure in AUTO MODE ...........................................................................Z-1
Z.1.1
Z.1.2
Z.1.3
Z.1.4
Radiation Field .........................................................................................................Z-1
Depiction of the Cervical Region .............................................................................Z-2
Depiction of the HIP JOINT AXL – 2 Menu ..............................................................Z-2
EDR Image Data Analysis .......................................................................................Z-3
Z.2
Precautions for Exposure in SEMI-AUTO MODE ...................................................Z-4
Z.3
Precautions for Exposure in SEMI-X MODE ...........................................................Z-5
Z.4
Precautions for Exposure in FIX MODE ......................................................................Z-6
Z.5
Precautions for the Automatic X-ray Detection Function.............................................Z-7
Z.5.1
Z.5.2
Z.6
Z.7
Precautions for Making an Exposure .......................................................................Z-7
Precautions Related to the X-ray Exposure Time ....................................................Z-8
Precautions for Use in Wireless Communication Mode ..............................................Z-9
Other Precautions .................................................................................................Z-10
Z.7.1
Z.7.2
Z.7.3
Z.7.4
Z.7.5
Z.7.6
Z.7.7
Z.7.8
Z.7.9
Z.7.10
Z.7.10
Precautions for Exposure of a Subject in Relatively Large Contrast .....................Z-10
Precautions for Flat Panel Sensor .........................................................................Z-10
Precautions for Assuring the Radiation Field .........................................................Z-10
Images Output When the X-ray Shot Switch is Operated Incorrectly ....................Z-10
Precautions for Urgent Use ...................................................................................Z-11
Precautions Related to Continuous Operation ......................................................Z-11
Precautions Related to Grid...................................................................................Z-11
Precautions during Calibration...............................................................................Z-11
Precautions for Exposing the Flat Panel Sensor to X-ray......................................Z-11
Precautions for Extended Image Readout .............................................................Z-11
Precautions for Using the Access Point ................................................................Z-12
Appendix O Use of Optional Items
O.1
Optional Items ....................................................................................................... O-1
O.2
Using the SE Storage Case ................................................................................... O-2
O.3
Using the Retaining Bracket for MP ....................................................................... O-3
O.4
DS Anchor Fixing Bracket ...................................................................................... O-4
O.5
Wall Fixing Bracket ................................................................................................. O-5
O.6
Access Point........................................................................................................... O-6
Maintenance and Inspection
5DGLRIUHTXHQF\ 5) FRPSOLDQFHLQIRUPDWLRQ
Compliance with 1999/5/EC ................................................................................................. 3
xiv
FDR D-EVO II Operation Manual
897N120339A
Chapter 1
For Safe Operation
 3UHFDXWLRQV%HIRUH2SHUDWLQJ7KLV
(TXLSPHQW
For Safe Operation
Before using this equipment, please read “Precautions Before Operating This Equipment” carefully so
that you can operate it correctly.
Whenever you operate this equipment, be sure to observe those precautions. Failure to do so may
cause you to subject to injuries or property damage to occur.
The institution where the equipment is installed is responsible for its use and
maintenance.
In addition, this equipment should not be used by persons other than doctors or
suitably trained staff.
7KLVV\VWHPLVFODVVLÂżHGDVDPHGLFDOGHYLFHXQGHU(&'LUHFWLYH((&
This equipment has been designed on the assumption that the patient would not
come into direct contact with it or for operation by appropriately trained operator.
Process waste correctly, as stipulated by local law or any regulations that apply.
Part of the components contains harmful substances which may pollute the ambient
environment if disposed carelessly. For details on product disposal, contact our
RIÂżFLDOGHDOHURU)8-,),/05HSUHVHQWDWLYH
FDR D-EVO II Operation Manual
897N120339A
1-1
1.2 Precautions to be Observed When
8VLQJWKH(OHFWULF0HGLFDO(TXLSPHQW
We ask that you observe these usage precautions and use the equipment correctly.
1. This equipment should be used only by people who have the proper skills.
2. Observe the following precautions when installing the equipment.
2-1. Install the equipment where water will not splash it.
2-2. Install the equipment where it will not be adversely affected by air pressure, temperature,
humidity, ventilation, sunlight, dust or the presence of salt, sulfur or like substances in the
atmosphere.
2-3. Make sure the equipment will remain in stable condition on a level surface and not be
subjected to vibration or shock.
2-4. Do not install the equipment in places where chemicals are stored or gases emitted.
2-5. Make sure that the power frequency, voltage and power consumption are appropriate.
2-6. Connect the ground wire correctly.
3. Observe the following precautions before beginning to use the device.
&RQÂżUPWKDWWKHJURXQGZLUHKDVEHHQFRPSOHWHO\FRQQHFWHG
3-2. Make sure that all cords have been connected properly and safely.
3-3. Be aware that correct diagnosis can be hindered and danger can result from using different
pieces of equipment together.
3-4. Make sure that the battery and power supply are installed properly.
4. Observe the following precautions when using the equipment.
4-1. Make sure not to exceed the time and dose required for diagnosis.
4-2. Always monitor the patient and the equipment for abnormalities.
4-3. Take an appropriate action, such as stopping the equipment after ensuring the patient’s
safety, if any abnormalities are found in his/her health or in the equipment.
5. Observe the following precautions after using the equipment.
5-1. Using the established procedure, then turn the power off.
5-2. When unplugging cords, do not pull on the body of the cord itself or apply unnecessary
force.
5-3. Observe the following precautions when storing the equipment.
I Store the equipment where water will not splash it.
II Store the equipment where it will not be adversely affected by air pressure, temperature,
humidity, ventilation, sunlight, dust or the presence of salt, sulfur or like substances in
the atmosphere.
III Make sure the equipment will remain in stable condition on a level surface and not be
subjected to vibration or shock.
IV Do not store the equipment in places where chemicals are stored or gases emitted.
5-4. After using the accessories, recollect them and put them back in order.
5-5. Make sure to clean the equipment for the next use.
 ,IWKHUHLVWURXEOHZLWKWKHHTXLSPHQWGRQRWDWWHPSWWRÂż[LWUDQGRPO\,QVWHDGGRZKDWLV
indicated and entrust repairs to a professional.
7. Do not remodel the equipment.
8. Maintenance and Inspection
8-1. Make inspect the equipment and parts periodically.
8-2. If the equipment has not been used for a long time, make sure that it operates normally and
safely prior to using it again.
9. Other Items
9-1. When subjecting patients (particularly infants and pregnant women) to radiation, make sure
not to exceed the necessary time and dose. Also, ensure that radiation is contained within
WKHH[SRVXUHSODQHRIWKHÀDWSDQHOVHQVRU
9-2. Follow the Operation Manual and operate the equipment correctly.
For Safe Operation
1-2
FDR D-EVO II Operation Manual
897N120339A
1.3 Safety
Before using the FDR D-EVO II, read this section thoroughly to ensure that you use the product
properly.
(OHFWULF6KRFN:DUQLQJVDQG&DXWLRQV
WARNING
For Safe Operation
The power supply to the FDR D-EVO II is AC100 to 240V.
7RDYRLGHOHFWULFVKRFNVXVHUVVKRXOGDOZD\VWDNHWKHIROORZLQJSUHFDXWLRQV
Ɣ 'RQRWRSHQDQ\FRYHUVZKHQLWLVQRWQHFHVVDU\
Ɣ ,QVWDOOWKHHTXLSPHQWLQDORFDWLRQZKHUHLWZLOOQRWEHH[SRVHGWRZDWHU
Ɣ 0DNHVXUHWKDWWKHJURXQGZLUHRIWKHHTXLSPHQWLVFRQQHFWHGFRPSOHWHO\
Ɣ &KHFNWKDWDOORIWKHFDEOHVDUHFRPSOHWHO\DQGVHFXUHO\FRQQHFWHG
Ɣ .HHSWKHFRQWUROFDELQHWRXWRIUHDFKRISDWLHQWV
WARNING
'RQRWWRXFKWKHSDWLHQWÂśVERG\ZKLOHWRXFKLQJWKHFRQWUROFDELQHWDQGWKHLPDJHSURFHVVLQJ
XQLW2WKHUZLVHWKHSDWLHQWPD\UHFHLYHDQHOHFWULFVKRFN
WARNING
'RQRWXVHDPXOWLSOHWDSFRQQHFWRURUH[WHQVLRQFDEOHIRUSRZHULQJWKHGHYLFHVFRQVWLWXWLQJ
WKHV\VWHP2WKHUZLVHÂżUHRUHOHFWULFVKRFNPD\RFFXUGXHWRWKHHOHFWULFDOORDGH[FHHGLQJWKH
allowable limit.
WARNING
2EVHUYHWKHIROORZLQJSUHFDXWLRQVZKHQXVLQJWKHFDEOHV
Ɣ 'RQRWWRXFKWKHSOXJDQGFRQQHFWRUZLWKZHWKDQGV2WKHUZLVHHOHFWULFVKRFNPD\UHVXOW
FDXVLQJGHDWKRUVHYHUHLQMXU\
Ɣ +ROGWKHSOXJRUFRQQHFWRUZKHQUHPRYLQJWKHFDEOH
 3XOOLQJWKHFDEOHRUFDUU\LQJE\KROGLQJLWPD\GDPDJHWKHFDEOHFDXVLQJÂżUHRUHOHFWULFVKRFN
Ɣ 'RQRWGDPDJHRUUHPRGHOWKHFDEOH
 'RQRWSODFHDKHDY\REMHFWRQWKHFDEOHRUOD\LWXQGHUWKHÀDWSDQHOVHQVRU'RQRWVWHSRQ
SXOOIRUFLEO\EHQGRUEXQGOHWKHFDEOH2WKHUZLVHÂżUHRUHOHFWULFVKRFNPD\UHVXOW
WARNING
'RQRWWXUQRQWKHV\VWHPZLWKGHZFRQGHQVDWLRQRQWKHÀDWSDQHOVHQVRU2WKHUZLVH¿UHRU
HOHFWULFVKRFNPD\UHVXOW
WARNING
'RQRWXVHWKHHTXLSPHQWLQDORFDWLRQZKHUHPHWDOSDUWLFOHVFRXOGFRPHLQWRWKHHTXLSPHQW
7KLVPD\FDXVHDQHOHFWULFVKRFN
WARNING
'RQRWGLVDVVHPEOHRUUHPRGHOWKHHTXLSPHQW2WKHUZLVHÂżUHRUHOHFWULFVKRFNPD\UHVXOW
.HHSDZD\IURPWKHSDUWVLQVLGHWKHSURGXFWZKLFKPD\FDXVHHOHFWULFVKRFN,I\RXWRXFK
them accidentally, death or severe injury may result.
FDR D-EVO II Operation Manual
897N120339A
1-3
WARNING
'RQRWKLWRUGURSWKHHTXLSPHQWRUVXEMHFWLWWRVHYHUHVKRFN2WKHUZLVHWKHHTXLSPHQWPD\
EHGDPDJHG,IWKHGDPDJHGHTXLSPHQWLVXVHGÂżUHRUHOHFWULFVKRFNPD\UHVXOW
,QDGGLWLRQGRQRWDSSO\VWURQJSUHVVXUHRQWRWKHÀDWSDQHOVHQVRU
,IDSSOLHGWKHÀDWSDQHOVHQVRUGHIRUPVDQGWKHZDWHUSURRIIXQFWLRQPD\EHFRPSURPLVHG
WARNING/AVERTISSEMENT
For Safe Operation
'RQRWXVHWKHÀDWSDQHOVHQVRUZLWKRXWWKHEDWWHU\SDFNV,IWKHEDWWHU\SDFNVDUHQRW
DWWDFKHGDQHOHFWULFVKRFNPD\UHVXOW
N’utilisez pas le détecteur à panneau plat sans les batteries. Si les batteries ne sont pas
FRQQHFWpHVXQFKRFpOHFWULTXHULVTXHGHVHSURGXLUH
WARNING
0DNHVXUHWRXVHWKHRSWLRQDOSDUWVDQGDFFHVVRULHVUHFRPPHQGHGE\XV)DLOXUHWRXVHWKH
RSWLRQDOSDUWVDQGDFFHVVRULHVUHFRPPHQGHGE\XVPD\UHVXOWLQGDPDJHWRWKHHTXLSPHQW
DQGRUHOHFWULFVKRFNDQGLQMXU\
CAUTIONS
$VWKHFDEOHVRIWKHHTXLSPHQWDUHORQJEHFDUHIXOQRWWRHQWDQJOHWKHFDEOHVGXULQJXVH
Also, be careful not to trip over the cables. Falls could result in injury.
CAUTIONS
)ROORZWKHVSHFL¿HGSURFHGXUHZKHQWXUQLQJRIIWKHHTXLSPHQW2WKHUZLVHWKHÀDWSDQHO
VHQVRUFRXOGEHGDPDJHGE\WKHUPDOVKRFN
CAUTIONS
'RQRWVWRUHPDJQHWLFPHGLDQHDUWKH'5V\VWHPDQGFRQWUROFDELQHW2WKHUZLVHPDJQHWLVP
JHQHUDWHGE\WKHHTXLSPHQWPD\FDXVHWKHGDWDWREHORVW
CAUTIONS
.HHSWKHHTXLSPHQWDZD\IURPSDWLHQW¶VERG\ÀXLGVFKHPLFDOVZDWHUHWF
2WKHUZLVHLWPD\EHFRPHGDPDJHGFDXVLQJÂżUHRUHOHFWULFVKRFN
,IQHFHVVDU\SURWHFWWKHÀDWSDQHOVHQVRUE\FRYHULQJLWZLWKDGLVSRVDEOHEDJ
([SORVLRQ:DUQLQJV
WARNING
%HFDXVHWKLVHTXLSPHQWLVQRWH[SORVLRQSURRIGRQRWXVHFRPEXVWLEOHDQGH[SORVLYHJDVHV
QHDUWKHHTXLSPHQW
WARNING
)ODPPDEOHJDVVHVPD\VWD\LQWKHURRPDIWHUGLVLQIHFWLRQ,I\RXWXUQWKHV\VWHPRQMXVWDIWHU
GLVLQIHFWLRQHQVXUHWKDWWKHURRPLVZHOOYHQWLODWHGEHIRUHSRZHULQJRQWKHV\VWHP
1-4
FDR D-EVO II Operation Manual
897N120339A
:DUQLQJVIRU$EQRUPDOLWLHV
WARNING
,IDQ\RIWKHIROORZLQJRFFXUVLPPHGLDWHO\WXUQRIIWKHSRZHURIHDFKXQLWXQSOXJWKHSRZHU
FDEOHIURPWKHRXWOHWDQGWKHQFRQWDFWRXURIÂżFLDOGHDOHURU)8-,),/05HSUHVHQWDWLYH
Ɣ :KHQVPRNHVWUDQJHRGRURUDEQRUPDOVRXQGLVSUHVHQW
Ɣ :KHQDIRUHLJQREMHFW VXFKDVDPHWDOREMHFW RUOLTXLGHQWHUVWKHSURGXFW
Ɣ :KHQWKHHTXLSPHQWLVGURSSHGRUKLWDQGLVGDPDJHG
For Safe Operation
Avertissements relatifs aux anomalies
AVERTISSEMENT
6LOÂśXQHGHVFRQGLWLRQVUpSHUWRULpHVFLDSUqVVHSURGXLWPHWWH]LPPpGLDWHPHQWFKDTXHXQLWp
hors tension, débranchez le cordon d’alimentation de la prise secteur, puis contactez notre
UHYHQGHXUDJUppRXQRWUHUHSUpVHQWDQW)8-,),/0
Ɣ (QFDVGHSUpVHQFHGHIXPpHG¶XQHRGHXUpWUDQJHRXG¶XQEUXLWDQRUPDO
Ɣ (QFDVGHSpQpWUDWLRQG¶XQFRUSVpWUDQJHU FRPPHXQREMHWPpWDOOLTXH RXG¶XQOLTXLGHGDQV
le produit.
Ɣ (QFDVG¶HQGRPPDJHPHQWGHO¶pTXLSHPHQWVXLWHjXQHFKXWHRXjXQLPSDFW
Installation Precautions
CAUTIONS
'RQRWLQVWDOOWKHV\VWHPLQDORFDWLRQZLWKWKHIROORZLQJFRQGLWLRQV
Ɣ :KHUHWKHWHPSHUDWXUHFKDQJHVVKDUSO\
Ɣ &ORVHWRKHDWVRXUFHVVXFKDVDKHDWHU
Ɣ :KHUHWKHV\VWHPPD\EHH[SRVHGWRZDWHUGXHWRZDWHUOHDNDJHRULQJUHVV
Ɣ :KHUHFRUURVLYHJDVPD\EHJHQHUDWHG
Ɣ :KHUHWKHUHLVH[FHVVLYHGXVW
Ɣ :KHUHWKHV\VWHPLVVXEMHFWWRIUHTXHQWRUH[FHVVLYHYLEUDWLRQVKRFN
Ɣ :KHUHWKHV\VWHPLVH[SRVHGWRGLUHFWVXQOLJKW
Ɣ :KHUHWKHUHLVQRYHQWLODWRU
CAUTIONS
8VHWKHHTXLSPHQWRQDÀDWSODFH,IWKHHTXLSPHQWIDOOVLWPD\FDXVHGDPDJHWRWKHHTXLSPHQW
or personal injury.
CAUTIONS
:KHQ\RXPRYHWKHHTXLSPHQWSODFHLWLQWKHFDVVHWWHVWRUDJHER[RIDPRELOH;UD\XQLWRUKROG
LWE\KDQGWRSUHYHQWLWIURPIDOOLQJ,IWKHFDUWLVXVHGWRPRYHWKHHTXLSPHQWSODFHLWKRUL]RQWDOO\
CAUTIONS
)RUYHWHULQDU\RUPRELOHDSSOLFDWLRQVSOHDVHFRQWDFWRXURIÂżFLDOGHDOHURU)8-,),/0
Representative.
CAUTIONS
:KHQWKHGHYLFHVDUHXVHGRXWGRRUVLQZLUHOHVVFRPPXQLFDWLRQPRGHFRQWDFWRXURIÂżFLDO
dealer or FUJIFILM Representative.
FDR D-EVO II Operation Manual
897N120339A
1-5
CAUTIONS/ATTENTION
Do not place any object in a place where removal of the power cable is prevented.
1HSODFH]DXFXQREMHWjXQHPSODFHPHQWJrQDQWOHGpEUDQFKHPHQWGXFkEOHGÂśDOLPHQWDWLRQ
CAUTIONS
7RHQVXUHRSWLPDOLPDJHTXDOLW\LWLVUHFRPPHQGHGWKDW\RXGRQRWXVHWKHÀDWSDQHOVHQVRU
QHDUGHYLFHV PRWRUWUDQVIRUPHUVZLWFKLQJVXSSO\HWF WKDWJHQHUDWHHOHFWURPDJQHWLFQRLVH
For Safe Operation
CAUTIONS
7RHQVXUHRSWLPDOLPDJHTXDOLW\LWLVUHFRPPHQGHGWKDW\RXGRQRWSODFHWKHFDEOHV SRZHU
FDEOHFRPPXQLFDWLRQFDEOHHWF RIWKHHTXLSPHQWQHDUGHYLFHV PRWRUWUDQVIRUPHUVZLWFKLQJ
VXSSO\HWF WKDWJHQHUDWHHOHFWURPDJQHWLFQRLVHDQGWKHLUFDEOHV
CAUTIONS
Do not install the power supply unit in a place where it may be contacted inadvertently. In
DGGLWLRQWDNHFDUHQRWWRPDNHFRQWDFWZLWKWKHSRZHUVXSSO\XQLWH[FHSWZKHQRSHUDWLQJWKH
main switch. If the fan inside the power supply unit malfunctions, the power supply unit may
EHFRPHKRWFDXVLQJLQMXU\
Connection Instructions
WARNING
0DNHVXUHWKDWWKHGHYLFHVWREHFRQQHFWHGWRWKHHTXLSPHQWDUHDXWKRUL]HGIRUFRQQHFWLRQ
WARNING
&RQQHFWWKHSDQHOXQLW'5,'38DQGWKHGRFNLQJXQLW'5,''8RQO\WRWKHDFFHVV
SRLQWLPDJHSURFHVVLQJXQLWRUWKHFRQWUROFDELQHW
3UHFDXWLRQVRQ([WHUQDO1HWZRUN&RQQHFWLRQ
CAUTIONS
:KHQDVHWWLQJRIWKHQHWZRUNWRZKLFKWKHHTXLSPHQWLVFRQQHFWHGKDVEHHQFKDQJHG
FKHFNWKDWWKHFKDQJHGRHVQRWDIIHFWWKHV\VWHPRSHUDWLRQDQGWDNHPHDVXUHVLIQHFHVVDU\
7KHVHWWLQJFKDQJHPD\LQFOXGHWKHIROORZLQJ
Ɣ &
 KDQJHRIFRQQHFWLRQGHVWLQDWLRQ
Ɣ $
 GGLWLRQRIGHYLFHV
Ɣ 5
 HPRYDORIGHYLFHV
Ɣ 8
 SGDWHRIGHYLFHV
Ɣ 8
 SJUDGHRIGHYLFHV
1-6
FDR D-EVO II Operation Manual
897N120339A
:DUQLQJVDQG&DXWLRQVRQ1HWZRUN
WARNING
0DNHVXUHWRXVHWKHRSWLRQDOSDUWVDFFHVVRULHVDQGQHWZRUNVUHFRPPHQGHGE\XV)DLOXUHWR
XVHWKHRSWLRQDOSDUWVDFFHVVRULHVDQGQHWZRUNVUHFRPPHQGHGE\XVPD\UHVXOWLQGDPDJHWR
WKHHTXLSPHQWDQGRUHOHFWULFVKRFNDQGLQMXU\
CAUTIONS
For Safe Operation
&RQQHFWWRWKH(WKHUQHW1HWZRUNRI%$6(7;RU%$6(7SUHVFULEHGLQWKH,(((VWDQGDUG
'RQRWFRQQHFWWHOHSKRQHOLQHVWR/$1FRQQHFWRU2QO\873W\SHVWUDLJKW/$1FDEOHVRISDLU
&DWHJRU\FDEOH &$7( RUKLJKHUDUHDSSURSULDWHIRUFRQQHFWLRQWRWKLVFRQQHFWRU
CAUTIONS
$IWHUFRQQHFWLQJWKLVV\VWHPWRWKHQHWZRUNZLWKRWKHUV\VWHPVFRQÂżUPWKDWWKHRWKHUV\VWHPV
DUHQRWDIIHFWHG,IWKH\DUHDIIHFWHGWDNHFRXQWHUPHDVXUHVVXFKDVQHWZRUNVHSDUDWLRQ
System Isolation Instructions
WARNING
To ensure complete system isolation, never install any unauthorized accessories or other such
items.
:KHQLWLVQHFHVVDU\WRLQVWDOODXWKRUL]HGDFFHVVRULHVRURSWLRQDOLWHPVFRQWDFWRXURIÂżFLDO
dealer or FUJIFILM Representative.
WARNING
.HHSHTXLSPHQWRWKHUWKDQWKRVHXVHGIRUSDWLHQWVRXWRIWKHLUUHDFKWRHQVXUHDSSURSULDWH
system isolation.
WARNING
,QQRUPDOXVHKDYHDSDWLHQWWDNHDSURSHUSRVLWLRQLQJIRUH[SRVXUH7KHRSHUDWRUVKRXOG
operate the system in a place where safety from radiation is ensured. The operator should
DOVRPDNHVXUHEHIRUHH[SRVXUHWKDWQRRQHEXWWKHSDWLHQWLVLQWKHH[SRVXUHDUHDDQGWKH
RSHUDWLQJDUHDRIWKHV\VWHP
Software Precautions
CAUTIONS
Do not install additional software to the system. Do not uninstall any of the software
preinstalled in the system.
The system is preinstalled with the appropriate software. If other software is installed or if the
H[LVWLQJVRIWZDUHLVXQLQVWDOOHGYDULRXVRSHUDWLRQDOHUURUVPD\UHVXOW
FDR D-EVO II Operation Manual
897N120339A
1-7
Disinfection Instructions
WARNING
&RQÂżUPWKDWWKHUHVSLUDWRU\GHQVLW\RIGLVLQIHFWDQWLQFOXGLQJVROYHQWLVXQGHUOHJDOUHJXODWLRQ
&HUWDLQGLVLQIHFWDQWVPD\GDPDJHKHDOWK:KHQXVLQJDGLVLQIHFWDQWIROORZLQVWUXFWLRQV
supplied by the manufacturers.
WARNING
For Safe Operation
'RQRWXVHWKHIROORZLQJGLVLQIHFWDQWVRUVWHULOL]HUVDWWKHWLPHRIGLVLQIHFWLRQ4XDOLW\
SHUIRUPDQFHDQGVDIHW\RIWKHHTXLSPHQWFDQQRWEHDVVXUHG
Ɣ &KORULFGLVLQIHFWDQWZKLFKLVVWURQJO\FRUURVLYHWRPHWDOVDQGUXEEHUSDUWV
Ɣ 'LVLQIHFWDQWZKRVHXVHVRQPHWDOVSODVWLFVDQGFRDWLQJDUHIRUELGGHQDFFRUGLQJWRWKH
instructions supplied with the disinfectant.
Ɣ )RUPDOLQJDVDQGGLVLQIHFWDQWVSUD\VWKDWPD\JHWLQVLGHWKHHTXLSPHQW
Ɣ 8OWUDYLROHWVWHULOL]HUV
Disinfectant ethanol is recommended for disinfection. Carefully read the instructions and
cautions supplied with the disinfectant before use.
For details on the disinfectant, contact a FUJIFILM dealer or the service representatives at the
DJHQF\IURPZKLFK\RXSXUFKDVHGWKHGLVLQIHFWDQW
CAUTIONS
,IÀDWSDQHOVHQVRULVQRWGLVLQIHFWHGLWPD\OHDGVHFRQGDU\LQIHFWLRQ
Be sure to disinfect with ethanol after use.
CAUTIONS
&OHDQWKHVHQVRUXQLWRIWKHÀDWSDQHOVHQVRUZLWKHWKDQROIRUGLVLQIHFWLRQHWFIRUHDFKSDWLHQW
to prevent infection.
3UHFDXWLRQVIRU&KDUJLQJWKH%DWWHU\3DFN
CAUTIONS
2EVHUYHWKHIROORZLQJSUHFDXWLRQVZKHQFKDUJLQJWKHEDWWHU\SDFN RSWLRQDO XVLQJWKHEDWWHU\
FKDUJHU RSWLRQDO 
Ɣ '
 RQRWXVHWKHEDWWHU\SDFN < RUEDWWHU\FKDUJHULQFRPELQDWLRQZLWKDQ\EDWWHU\
SDFNRUEDWWHU\FKDUJHU LQFOXGLQJWKHSRZHUFDEOH RWKHUWKDQWKRVHUHFRPPHQGHGE\
FUJIFILM Corporation.
Ɣ 'RQRWGLVDVVHPEOHRUFRQYHUWWKHEDWWHU\SDFNRUEDWWHU\FKDUJHU
Ɣ ,IWKHEDWWHU\SDFNRUEDWWHU\FKDUJHUEHFRPHVIDXOW\FRQVXOWRXURI¿FLDOGHDOHURU)8-,),/0
Representative.
Ɣ 'RQRWFRYHUWKHKROHVLQWKHEDWWHU\FKDUJHUZLWKIRUHLJQPDWWHU
Ɣ $YRLGWKHDFFXPXODWLRQRIGXVWRQWKHEDWWHU\FKDUJHU
Ɣ ,QVHUWWKHEDWWHU\SDFNLQWRWKHEDWWHU\FKDUJHUVHFXUHO\
Ɣ ,IWKHLQVHUWLRQGLUHFWLRQRUSRVLWLRQRIWKHEDWWHU\SDFNLVLQFRUUHFWWKHEDWWHU\SDFNLVQRW
FKDUJHGSURSHUO\
Ɣ :
 KHQLQVHUWLQJWKHEDWWHU\SDFNSUHYHQWIRUHLJQPDWWHUIURPJHWWLQJLQWRWKHEDWWHU\FKDUJHU
Ɣ :
 KLOHFKDUJLQJWKHEDWWHU\SDFNGRQRWDOORZWKHEDWWHU\SDFNRUEDWWHU\FKDUJHUJHWZHWRU
dusty.
Ɣ '
 RQRWVWHSRQWKH$&DGDSWHURIWKHEDWWHU\FKDUJHU$OVREHFDUHIXOQRWWRWULSRYHUWKH
power cable.
Ɣ '
 RQRWVXEMHFWWKHEDWWHU\SDFNDQGEDWWHU\FKDUJHUWRVHYHUHVKRFN E\GURSSLQJWKHPHWF 
Ɣ 'RQRWSODFHWKHEDWWHU\FKDUJHUZLWKLQWKHUHDFKRISDWLHQWV
1-8
FDR D-EVO II Operation Manual
897N120339A
Ɣ '
 RQRWFKDUJHWKHEDWWHU\SDFNQHDUÂżUHRUXQGHUVWURQJVXQVKLQH,IWKHEXLOWLQSURWHFWLRQ
PHFKDQLVPVDUHDFWLYDWHGE\DKLJKWHPSHUDWXUHWKHEDWWHU\SDFNFDQQRWEHFKDUJHG$OVR
LIWKHEXLOWLQSURWHFWLRQPHFKDQLVPVDUHGDPDJHGWKHEDWWHU\SDFNPD\EHFKDUJHGZLWK
H[WUHPHO\KLJKFXUUHQWDQGYROWDJHDQGDEQRUPDOFKHPLFDOUHDFWLRQVPD\RFFXULQVLGHWKH
EDWWHU\SDFNFDXVLQJLWWRRYHUKHDWHPLWVPRNHH[SORGHRULJQLWH
Ɣ 7
 RFKDUJHWKHEDWWHU\SDFNEHVXUHWRXVHWKHGHVLJQDWHGEDWWHU\FKDUJHUDQGWRREVHUYH
WKHFKDUJLQJFRQGLWLRQVVSHFLÂżHGE\)8-,),/0&RUSRUDWLRQ,IWKHEDWWHU\SDFNLVFKDUJHGLQ
RWKHUFRQGLWLRQV WHPSHUDWXUHRUYROWDJHFXUUHQWKLJKHUWKDQVSHFLÂżHGUHPRGHOHGEDWWHU\
FKDUJHUHWF WKHEDWWHU\SDFNPD\EHRYHUFKDUJHGRUFKDUJHGZLWKH[WUHPHO\KLJKFXUUHQW
DQGDEQRUPDOFKHPLFDOUHDFWLRQVPD\RFFXULQVLGHWKHEDWWHU\SDFNFDXVLQJLWWRRYHUKHDW
HPLWVPRNHH[SORGHRULJQLWH
Ɣ ,PPHGLDWHO\VWRSFKDUJLQJWKHEDWWHU\SDFNLIFKDUJLQJLVQRWFRPSOHWHGZLWKLQWKHVSHFL¿HG
WLPH2WKHUZLVHWKHEDWWHU\SDFNPD\RYHUKHDWHPLWVPRNHH[SORGHRULJQLWH
Ɣ '
 RQRWXVHWKHÀDWSDQHOVHQVRUQHDUWKHSRZHUFDEOH
Ɣ 'RQRWXVHDIDXOW\RUEURNHQEDWWHU\FKDUJHURU$&DGDSWHU
Ɣ 1
 RWHWKDWWKHÀDWSDQHOVHQVRUFDQQRWEHFKDUJHGE\XVLQJWKH6(FRPPXQLFDWLRQFDEOHWKDW
FRQQHFWVWKHÀDWSDQHOVHQVRUDQGWKHDFFHVVSRLQW RSWLRQDO 
For Safe Operation
%DWWHU\3DFN,QVWUXFWLRQV
WARNING
Ɣ %DWWHU\SDFNUHTXLUHVUHJXODUFKHFNXSDQGUHSODFHPHQW%DWWHU\FDSDFLW\EHJLQVWRZDQH
after a period of time.
Ɣ ,IWKLVHTXLSPHQWLVQRWLQXVHIRUZKLOHVWRUHLWZLWKWKHEDWWHU\SDFNUHPRYHG
1RWUHPRYLQJWKHEDWWHU\SDFNPD\FDXVHPDOIXQFWLRQ
CAUTIONS
2EVHUYHWKHIROORZLQJSUHFDXWLRQVZKHQXVLQJWKHEDWWHU\SDFN RSWLRQDO 
Ɣ 7
 KHEDWWHU\SDFN 1 LVXVHGZLWKWKHÀDWSDQHOVHQVRU'RQRWXVHWKHPLQRWKHU
combinations.
Ɣ &
 KDUJHWKHEDWWHU\SDFNRQO\ZLWKWKHGHVLJQDWHGEDWWHU\FKDUJHU,IWKHEDWWHU\SDFNLV
FKDUJHGXQGHUWKHFKDUJLQJFRQGLWLRQV YROWDJHFXUUHQWDQGFKDUJLQJPHWKRG GLIIHUHQW
IURPWKRVHVSHFLÂżHGE\)8-,),/0&RUSRUDWLRQWKHEDWWHU\SDFNPD\HPLWVPRNHLJQLWH
H[SORGHRUOHDNÀXLG
Ɣ 6
 WRUHWKHEDWWHU\SDFNLQDFRRODQGGDUNSODFH5HFKDUJHWKHVWRUHGEDWWHU\SDFNHYHU\VL[
months or every year. Otherwise a decrease in battery capacity or other problems may result.
Ɣ '
 RQRWOHDYHWKHUHPRYHGEDWWHU\SDFNLQWKHFDURURWKHUSODFHVH[SRVHGWRKLJK
WHPSHUDWXUH,IWKHEDWWHU\SDFNLVXVHGRUVWRUHGLQDSODFHZKHUHLWLVH[SRVHGWRKLJK
WHPSHUDWXUHWKHEDWWHU\SDFNPD\HPLWVPRNHLJQLWHH[SORGHRUOHDNÀXLG
Ɣ 8
 VHRUVWRUHWKHEDWWHU\SDFNRQO\LQWKHHQYLURQPHQWDOFRQGLWLRQVVSHFLÂżHGE\)8-,),/0
&RUSRUDWLRQ,IWKHEDWWHU\SDFNLVXVHGRUVWRUHGLQDSODFHZKHUHLWLVH[SRVHGWRKLJK
WHPSHUDWXUHWKHEDWWHU\SDFNPD\HPLWVPRNHLJQLWHH[SORGHRUOHDNÀXLG
Ɣ :KHQGLVSRVLQJRIWKHEDWWHU\SDFNFRQVXOWRXURI¿FLDOGHDOHURU)8-,),/05HSUHVHQWDWLYH
Ɣ '
 RQRWGLVDVVHPEOHRUUHPRGHOWKHEDWWHU\SDFN7KHEDWWHU\SDFNLVHTXLSSHGZLWKEXLOWLQ
VDIHW\DQGSURWHFWLRQPHFKDQLVPV,IWKH\DUHGDPDJHGWKHEDWWHU\SDFNPD\RYHUKHDWHPLW
VPRNHH[SORGHRULJQLWH
Ɣ %HFDUHIXOQRWWRGURSWKHEDWWHU\SDFN7KHSDWLHQWPD\EHLQMXUHG
Ɣ 'RQRWWRXFKWKHWHUPLQDORIWKHEDWWHU\SDFNGLUHFWO\7KHUHLVDULVNRIHOHFWULFVKRFN
Ɣ '
 RQRWFRQQHFWWKHSRVLWLYH  DQGQHJDWLYH  WHUPLQDOVZLWKDZLUHRUDQ\PHWDOREMHFW
'RQRWFDUU\RUVWRUHWKHEDWWHU\SDFNWRJHWKHUZLWKPHWDOREMHFWVVXFKDVQHFNODFHVRU
KDLUSLQV2WKHUZLVHWKHEDWWHU\SDFNPD\VKRUWFLUFXLWDQGRYHUFXUUHQWPD\ÀRZFDXVLQJ
WKHEDWWHU\SDFNWRRYHUKHDWHPLWVPRNHH[SORGHRULJQLWH0HWDOREMHFWVVXFKDVQHFNODFHV
or hairpins may also become hot.
Ɣ '
 RQRWWKURZWKHEDWWHU\SDFNLQWRÂżUHRUH[SRVHLWWRH[FHVVLYHKHDW2WKHUZLVHLWVLQVXODWRU
PD\PHOWLWVJDVUHOHDVHYHQWRUVDIHW\PHFKDQLVPVPD\EHGDPDJHGDQGRULWVHOHFWURO\WH
PD\FDWFKÂżUHFDXVLQJWKHEDWWHU\SDFNWRRYHUKHDWHPLWVPRNHH[SORGHRULJQLWH
Ɣ '
 RQRWXVHRUOHDYHWKHEDWWHU\SDFNLQDSODFHZKHUHLWLVH[SRVHGWRKLJKWHPSHUDWXUH ƒ&
RUKLJKHU VXFKDVÂżUHRUDKHDWHU,IWKHUHVLQVHSDUDWRULVGDPDJHGGXHWRKHDWWKHEDWWHU\
SDFNPD\VKRUWFLUFXLWFDXVLQJLWWRRYHUKHDWHPLWVPRNHH[SORGHRULJQLWH
FDR D-EVO II Operation Manual
897N120339A
1-9
Ɣ '
 RQRWLPPHUVHWKHEDWWHU\SDFNLQZDWHURUVHDZDWHUDQGGRQRWDOORZLWWREHFRPHZHW
,IWKHEXLOWLQSURWHFWLRQPHFKDQLVPVDUHGDPDJHGWKHEDWWHU\SDFNPD\RYHUKHDWHPLW
VPRNHH[SORGHRULJQLWH
Ɣ '
 RQRWSLHUFHWKHEDWWHU\SDFNZLWKDQDLOKLWLWZLWKDKDPPHURUVWHSRQLW2WKHUZLVHWKH
EDWWHU\SDFNPD\EHGDPDJHGRUGHIRUPHGDQGVKRUWFLUFXLWFDXVLQJLWWRRYHUKHDWHPLW
VPRNHH[SORGHRULJQLWH
Ɣ '
 RQRWVXEMHFWWKHEDWWHU\SDFNWRVWURQJLPSDFWRUWKURZLW,IWKHEXLOWLQSURWHFWLRQ
PHFKDQLVPVDUHGDPDJHGWKHEDWWHU\SDFNPD\EHFKDUJHGZLWKH[WUHPHO\KLJKFXUUHQWDQG
YROWDJHDQGDEQRUPDOFKHPLFDOUHDFWLRQVPD\RFFXULQVLGHWKHEDWWHU\SDFNFDXVLQJLWWR
RYHUKHDWHPLWVPRNHH[SORGHRULJQLWH
Ɣ '
 RQRWXVHDQDSSDUHQWO\GDPDJHGRUGHIRUPHGEDWWHU\SDFN2WKHUZLVHWKHEDWWHU\SDFN
PD\RYHUKHDWHPLWVPRNHH[SORGHRULJQLWH
Ɣ '
 RQRWVROGHUWKHEDWWHU\SDFNGLUHFWO\2WKHUZLVHLWVLQVXODWRUPD\PHOWRULWVJDVUHOHDVH
YHQWRUVDIHW\PHFKDQLVPVPD\EHGDPDJHGFDXVLQJWKHEDWWHU\SDFNWRRYHUKHDWHPLW
VPRNHH[SORGHRULJQLWH
Ɣ '
 RQRWUHYHUVHWKHSRVLWLYH  DQGQHJDWLYH  WHUPLQDOV2WKHUZLVHWKHEDWWHU\SDFNPD\
EHUHYHUVHFKDUJHGGXULQJFKDUJLQJ$VDUHVXOWDEQRUPDOFKHPLFDOUHDFWLRQVPD\RFFXU
LQVLGHWKHEDWWHU\SDFNRUH[WUHPHO\KLJKFXUUHQWPD\ÀRZGXULQJGLVFKDUJLQJFDXVLQJLWWR
RYHUKHDWHPLWVPRNHH[SORGHRULJQLWH
Ɣ 7
 KHEDWWHU\SDFNKDVDSUHGHWHUPLQHGSRODULW\,I\RXFDQQRWFRQQHFWWKHEDWWHU\SDFNWRWKH
EDWWHU\FKDUJHURURWKHUHTXLSPHQWGRQRWFRQQHFWWKHEDWWHU\SDFNIRUFHIXOO\0DNHVXUH
WKDWWKHWHUPLQDOVDUHFRUUHFWO\RULHQWHG,IWKHEDWWHU\SDFNLVFRQQHFWHGLQUHYHUVHLWZLOO
EHUHYHUVHFKDUJHGDQGDEQRUPDOFKHPLFDOUHDFWLRQVPD\RFFXULQVLGHWKHEDWWHU\SDFN
FDXVLQJLWWRRYHUKHDWHPLWVPRNHH[SORGHRULJQLWH
Ɣ '
 RQRWFRQQHFWWKHEDWWHU\SDFNWRDQHOHFWULFDORXWOHWRUFLJDUHWWHOLJKWHUVRFNHWLQDFDU
2YHUFXUUHQWPD\ÀRZWRWKHEDWWHU\SDFNGXHWRKLJKYROWDJHDSSOLHGFDXVLQJWKHEDWWHU\
SDFNWRRYHUKHDWHPLWVPRNHH[SORGHRULJQLWH
Ɣ '
 RQRWXVHWKHEDWWHU\SDFNIRUHTXLSPHQWRWKHUWKDQWKRVHVSHFLÂżHG2WKHUZLVHWKH
JXDUDQWHHGSHUIRUPDQFHZLOOEHUHGXFHGDQGRUWKHVHUYLFHOLIHZLOOEHVKRUWHQHG'HSHQGLQJ
RQWKHHTXLSPHQWWRZKLFKWKHEDWWHU\SDFNLVFRQQHFWHGH[WUHPHO\KLJKFXUUHQWPD\ÀRZ
FDXVLQJWKHEDWWHU\SDFNWREHGDPDJHGRYHUKHDWHPLWVPRNHH[SORGHRULJQLWH
Ɣ ,IWKHHOHFWURO\WHOHDNHGIURPWKHEDWWHU\SDFNHQWHUVWKHH\HVGRQRWUXEWKHP:DVKWKH
eyes immediately with clean water such as tap water, and consult a doctor. Otherwise, eye
injury may result.
Ɣ '
 RQRWXVHWKHEDWWHU\SDFNLQFRPELQDWLRQZLWKDSULPDU\EDWWHU\VXFKDVDGU\EDWWHU\RU
RWKHUEDWWHU\RIDGLIIHUHQWFDSDFLW\W\SHDQGRUEUDQG2WKHUZLVHWKHEDWWHU\SDFNPD\
EHRYHUFKDUJHGGXULQJFKDUJLQJDQGDEQRUPDOFKHPLFDOUHDFWLRQVPD\RFFXULQVLGHWKH
EDWWHU\SDFNFDXVLQJLWWRRYHUKHDWHPLWVPRNHH[SORGHRULJQLWH
Ɣ '
 RQRWSXWWKHEDWWHU\SDFNLQDPLFURZDYHRYHQRUKLJKSUHVVXUHFRQWDLQHU2WKHUZLVHWKH
EDWWHU\SDFNPD\EHUDSLGO\KHDWHGRUGDPDJHGFDXVLQJLWWRRYHUKHDWHPLWVPRNHH[SORGH
RULJQLWH
Ɣ ,IWKHEDWWHU\SDFNOHDNVRUHPLWVDQXQXVXDORGRUUHPRYHLWIURP¿UHLPPHGLDWHO\
2WKHUZLVHWKHOHDNHGHOHFWURO\WHPD\FDWFKÂżUHFDXVLQJWKHEDWWHU\SDFNWRRYHUKHDWHPLW
VPRNHH[SORGHRULJQLWH
Ɣ ,I\RXQRWLFHDQXQXVXDORGRUKHDWGLVFRORUDWLRQGHIRUPDWLRQRUDQ\RWKHUDEQRUPDOLW\GXULQJ
XVHFKDUJLQJRUVWRUDJHUHPRYHWKHEDWWHU\SDFNIURPWKHHTXLSPHQWRUEDWWHU\FKDUJHUDQG
VWRSXVLQJLW2WKHUZLVHWKHEDWWHU\SDFNPD\RYHUKHDWHPLWVPRNHH[SORGHRULJQLWH
Ɣ '
 RQRWXVHWKHEDWWHU\SDFNH[SRVHGWRDVWURQJPDJQHWLFÂżHOGRIDQ05,V\VWHPHWF
Ɣ 'RQRWXVHWKHEDWWHU\SDFNLPPHUVHGLQOLTXLG
For Safe Operation
:DUQLQJVIRU3HGLDWULF8VH
WARNING
Ɣ ,IWKHH[SRVXUHFRQGLWLRQVIRUDYHUDJHVL]HDGXOWVDUHDSSOLHGWRFKLOGUHQLWPD\FDXVH
excessive radiation exposure.
Ɣ 6WXGLHVVKRZWKDWFKLOGUHQDUHPRUHUDGLRVHQVLWLYHWKDQDGXOWV LHFKLOGUHQDUHDWKLJKHU
ULVNRIGHYHORSLQJFDQFHUFRPSDUHGWRDGXOWVH[SRVHGWRWKHVDPHGRVHRILRQL]LQJ
UDGLDWLRQ $FFRUGLQJO\LQSHGLDWULFXVHVSHFLDODWWHQWLRQQHHGVWREHSDLGWRDYRLG
unnecessary exposure.
Ɣ %DVHGRQWKHFOLQLFDODSSOLFDWLRQSDWKRORJLFDOFRQGLWLRQVRIWKHSDWLHQWSDWLHQWVL]HDQG
DQDWRPLFDOLPDJLQJUHJLRQDGMXVWWKHH[SRVXUHFRQGLWLRQVWRXVHWKHPLQLPXPDPRXQWRI
UDGLDWLRQQHFHVVDU\WRREWDLQDSSURSULDWHPHGLFDOLPDJHV
Ɣ $QDGGLWLRQDO¿OWHUFDQDOVREHXVHGIRUFKLOGUHQWRUHGXFHXQQHFHVVDU\H[SRVXUHIXUWKHU
1-10
FDR D-EVO II Operation Manual
897N120339A
Ɣ ,IFKLOGUHQFDQQRWEHH[SRVHGDWDQDSSURSULDWHGRVHZLWKWKH$(&GRQRWXVHWKH$(&
Ɣ $GMXVWWKHH[SRVXUHFRQGLWLRQVWRPLQLPL]HWKH;UD\H[SRVXUHWLPHWRDYRLGUHSHDWHG
exposure due to body movement.
2WKHU:DUQLQJVDQG&DXWLRQV
WARNING
1RPRGLÂżFDWLRQRIWKLVHTXLSPHQWLVDOORZHG
For Safe Operation
CAUTIONS
Install the system in accordance with what is provided by IEC 60601-1-1:2000 and IEC 60601&KDSWHU&RQWDFWRXURIÂżFLDOGHDOHURU)8-,),/05HSUHVHQWDWLYHIRULQVWDOODWLRQ
H[FHSWWKHÀDWSDQHOVHQVRU RIWKHV\VWHP
CAUTIONS
'RQRWKLWRUGURSWKHHTXLSPHQW2WKHUZLVHLQMXU\RUGDPDJHWRLPDJHVHWFPD\UHVXOW
CAUTIONS
Be sure to inspect the system periodically.
7RDVVXUHRSWLPXPSHUIRUPDQFHRIWKHHTXLSPHQWLWLVQHFHVVDU\WRV\VWHPDWLFDOO\SHUIRUP
maintenance and inspection. For information on maintenance and inspection, contact our
RIÂżFLDOGHDOHURU)8-,),/05HSUHVHQWDWLYH
CAUTIONS
'RQRWSHUIRUPPDLQWHQDQFHDQGLQVSHFWLRQZKLOHWKHHTXLSPHQWLVXVHGIRUDSDWLHQW
CAUTIONS
$OWKRXJKWKHÀDWSDQHOVHQVRUFRQIRUPVWR,3;QRZDUUDQW\LVJLYHQDVWRWKHSUHYHQWLRQRI
ZDWHULQWUXVLRQLQWKHÀDWSDQHOVHQVRU,IWKHÀDWSDQHOVHQVRULVVSODVKHGZLWKZDWHUZLSHRII
PRLVWXUHDQGHQVXUHWKDWWKHÀDWSDQHOVHQVRULVFRPSOHWHO\GU\EHIRUHXVH
Contraindications and Prohibitions
No contraindications present.
&ODVVLÂżFDWLRQ
Ɣ $
 FFRUGLQJWRWKHW\SHRISURWHFWLRQDJDLQVWHOHFWULFDOVKRFN
Class 1 equipment
Ɣ $FFRUGLQJWRWKHGHJUHHRISURWHFWLRQDJDLQVWHOHFWULFDOVKRFN
Type B applied part
Ɣ $FFRUGLQJWRWKHGHJUHHRISURWHFWLRQDJDLQVWKDUPIXOLQJUHVVRIZDWHU
 ,3; 7KHÀDWSDQHOVHQVRUFRQIRUPVWR,3;
Ɣ $
 FFRUGLQJWRWKHGHJUHHRIVDIHW\RIDSSOLFDWLRQLQWKHSUHVHQFHRIDÀDPPDEOHDQHVWKHWLFV
mixture with air or with oxygen or nitrous oxide.
 (
 TXLSPHQWQRWVXLWDEOHIRUXVHLQWKHSUHVHQFHRIDÀDPPDEOHDQHVWKHWLFVPL[WXUHZLWKDLURUZLWK
oxygen or nitrous oxide.
Ɣ $FFRUGLQJWRWKHPRGHRIRSHUDWLRQ
CONTINUOUS OPERATION
FDR D-EVO II Operation Manual
897N120339A
1-11
 (OHFWURPDJQHWLF&RPSDWLELOLW\ (0&
Essential performance
(1) DR-ID 1201SE/DR-ID 1202SE/DR-ID 1211SE/DR-ID 1212SE obtains images.
(2) DR-ID 1200MC stores images.
(3) DR-ID 1200MC corrects images.
(4) Image transfer in order from DR-ID 1201SE/DR-ID 1202SE/DR-ID 1211SE/DR-ID 1212SE to the DR-ID 1200MC
or the image processing unit.
(5) Image processing unit stores and displays images after correction.
 ,WVKDOOIXOÂżOODQGPDLQWDLQWKHVDIHW\UHTXLUHPHQWRIWKHVWDQGDUGV
For Safe Operation
DR-ID 1200 is consists of following components and conforms to IEC 60601-1-2 as a result of each component
conforms to following standards.
1.4.1 DR-ID 1200
DR-ID 1200 consists of DR-ID 1200MC, DR-ID 300CL , DR-ID 1200MP , DR-ID 1200DS and DR-ID 1201SE/
DR-ID 1202SE/DR-ID 1211SE/DR-ID 1212SE
This equipment has been tested and found to comply with the limits for medical devices to the IEC
60601-1-2 (EN 60601-1-2), Medical Device Directive 93/42/EEC.
These limits are designed to provide reasonable protection against harmful interference in a typical
medical installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to other devices in the
vicinity.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to other devices, which can be determined by
tuning the equipment off and on, the user is encouraged to try to correct the interference by one or
PRUHRIWKHIROORZLQJPHDVXUHV
• Reorient or relocate the receiving device.
• Increase the separation between the equipment.
• Connect the equipment into an outlet on a circuit different from that to which the other device(s)
are connected.
If the problem cannot be solved with the above measures, stop using this equipment and consult
WKHPDQXIDFWXUHURXURIÂżFLDOGHDOHURU)8-,),/05HSUHVHQWDWLYHIRUKHOS
WARNING
Ɣ 'RQRWSODFHGHYLFHVJHQHUDWLQJHOHFWURPDJQHWLFZDYHQHDUWKLVHTXLSPHQW
Ɣ ,IDGHYLFH V RWKHUWKDQWKRVHVSHFL¿HGLVFRQQHFWHGSUHGHWHUPLQHG(0&SHUIRUPDQFH
FDQQRWEHJXDUDQWHHG
1-12
FDR D-EVO II Operation Manual
897N120339A
Further Information for IEC 60601-1-2 (EN 60601-1-2)
1. Medical electrical equipment needs special precautions regarding EMC and needs to be installed
and put into service according to the EMC information provided in the accompanying documents.
2. Portable and mobile RF communications equipment can affect medical electrical equipment.
3. Information regarding the cable affecting EMC is as follows.
Name
Connected Device
Network Cable
Between the DR-ID 1200PU
and the DR-ID 1200MC
0D[LPXP/HQJWK
20m (65.6 ft)
*HQHUDO6SHFLÂżFDWLRQ
Cat5e or more,
UTP type and straight cable
For Safe Operation
Between the DR-ID 1200DU
and the DR-ID 1200MC
Between the DR-ID 1200MC
and the DR-ID 300CL
Power Cable
DR-ID 1200MC, DR-ID
300CL
Use a hospital grade power cable. (for North America)
A non-hospital grade power cable can be used. (for
other countries)
4. 7KHXVHRIDFFHVVRULHVWUDQVGXFHUVDQGFDEOHVRWKHUWKDQWKRVHVSHFLÂżHGZLWKWKHH[FHSWLRQRI
transducers and cables sold by FUJIFILM Corporation as replacement parts for internal components,
may result in increased emissions or decreased immunity of the DR-ID 1200.
5. The DR-ID 1200 should not be used adjacent to or stacked with other equipment.
If adjacent or stacked use is necessary, the DR-ID 1200 should be observed to verify normal
RSHUDWLRQLQWKHFRQÂżJXUDWLRQLQZKLFKLWZLOOEHXVHG
6. Basic performance of the equipment and the system
$IWHULPDJHGDWDDUHDFTXLUHGIURPWKHÀDWSDQHOVHQVRUGDWDFRUUHFWLRQLVSHUIRUPHGE\WKHFRQWUROFDELQHW
(DR-ID 1200MC), and the image is saved in and displayed on the image processing unit.
7. Test items (Tables 1 to 4)
Table 1
*XLGDQFHDQGPDQXIDFWXUHUÂśVGHFODUDWLRQHOHFWURPDJQHWLFHPLVVLRQV
7KH'5,'LVLQWHQGHGIRUXVHLQWKHHOHFWURPDJQHWLFHQYLURQPHQWVSHFLÂżHGEHORZ
The customer or the user of the DR-ID 1200 should assure that it is used in such an environment.
Emissions test
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-2
9ROWDJHÀXFWXDWLRQV
ÀLFNHUHPLVVLRQV
IEC 61000-3-3
Compliance
Group 1
(OHFWURPDJQHWLFHQYLURQPHQWJXLGDQFH
The DR-ID 1200 uses RF energy only for their internal
function.
Therefore, their RF emissions are very low and are not
likely to cause any interference in nearby electronic
equipment.
Class B
Complies '5,'&ODVV$
Complies
The DR-ID 1200 is suitable for use in all establishments,
including domestic establishments and those directly
connected to the public low-voltage power supply network
that supplies buildings used for domestic purposes.
FDR D-EVO II Operation Manual
897N120339A
1-13
Table 2
*XLGDQFHDQGPDQXIDFWXUHUÂśVGHFODUDWLRQHOHFWURPDJQHWLFLPPXQLW\
7KH'5,'LVLQWHQGHGIRUXVHLQWKHHOHFWURPDJQHWLFHQYLURQPHQWVSHFLÂżHGEHORZ
The customer or the user of the DR-ID 1200 should assure that it is used in such an environment.
Immunity test
IEC 60601-1-2
test level
Compliance level
(OHFWURPDJQHWLFHQYLURQPHQW
JXLGDQFH
Electrostatic
discharge
(ESD)
IEC 61000-4-2
Âą6kV contact
Âą8kV air
Âą6kV contact
Âą8kV air
Floors should be wood, concrete or
FHUDPLFWLOH,IÀRRUVDUHFRYHUHGZLWK
synthetic material, the relative humidity
should be at least 30%.
For Safe Operation
Electrical fast
transient/burst
IEC 61000-4-4
Âą2kV for power supply
lines
Âą1kV for input/output
lines
Âą2kV for power supply
lines
Âą1kV for input/output
lines
Mains power quality should be that
of a typical commercial or hospital
environment.
Surge
IEC 61000-4-5
Âą1kV differential mode
Âą2kV common mode
Âą1kV differential mode
Âą2kV common mode
Mains power quality should be that
of a typical commercial or hospital
environment.
Voltage dips, short
interruptions and
voltage variations on
power supply input
lines
IEC 61000-4-11
<5% UT
(>95% dip in UT)
for 0.5 cycle
40% UT
(60% dip in UT)
for 5 cycles
70% UT
(30% dip in UT)
for 25 cycles
<5% UT
(>95% dip in UT)
for 5 s
<5% UT
(>95% dip in UT)
for 0.5 cycle
40% UT
(60% dip in UT)
for 5 cycles
70% UT
(30% dip in UT)
for 25 cycles
<5% UT
(>95% dip in UT)
for 5 s
Mains power quality should be that
of a typical commercial or hospital
environment. If the user of the DR-ID
1200 requires continued operation
during power mains interruptions, it is
recommended that the DR-ID 1200 be
powered from an uninterruptible power
supply or a battery.
3 A/m
3RZHUIUHTXHQF\PDJQHWLFÂżHOGVVKRXOG
be at levels characteristic of a typical
location in a typical commercial or
hospital environment.
Power frequency
(50/60Hz) magnetic
ÂżHOG
IEC 61000-4-8
3 A/m
127(UT is the a.c. mains voltage prior to application of the test level.
1-14
FDR D-EVO II Operation Manual
897N120339A
Table 3
*XLGDQFHDQGPDQXIDFWXUHUÂśVGHFODUDWLRQHOHFWURPDJQHWLFLPPXQLW\
7KH'5,'LVLQWHQGHGIRUXVHLQWKHHOHFWURPDJQHWLFHQYLURQPHQWVSHFLÂżHGEHORZ
The customer or the user of the DR-ID 1200 should assure that it is used in such an environment.
Immunity test
IEC 60601-1-2
test level
Compliance level
3 Vrms
150 kHz to 80 MHz
3 Vrms
Radiated RF
IEC 61000-4-3
3 V/m
80 MHz to 2.5 GHz
3 V/m
Portable and mobile RF communications equipment
should be used no closer to any part of the DR-ID
1200, including cables, than the recommended
separation distance calculated from the equation
applicable to the frequency of the transmitter.
For Safe Operation
Conducted RF
IEC 61000-4-6
(OHFWURPDJQHWLFHQYLURQPHQWJXLGDQFH
Recommended separation distance
d = 1.2
d = 1.2
80 MHz to 800 MHz
d = 2.3
800 MHz to 2.5 GHz
where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter
manufacturer and d is the recommended separation
distance in metres (m).
)LHOGVWUHQJWKVIURPÂż[HG5)WUDQVPLWWHUVDV
determined by an electromagnetic site survey,a
should be less than the compliance level in each
frequency range.b
Interference may occur in the vicinity of equipment
PDUNHGZLWKWKHIROORZLQJV\PERO
127($W0+]DQG0+]WKHKLJKHUIUHTXHQF\UDQJHDSSOLHV
127(7KHVHJXLGHOLQHVPD\QRWDSSO\LQDOOVLWXDWLRQV(OHFWURPDJQHWLFSURSDJDWLRQLVDIIHFWHGE\DEVRUSWLRQDQG
UHÀHFWLRQIURPVWUXFWXUHVREMHFWVDQGSHRSOH
D )LHOGVWUHQJWKIURPÂż[HGWUDQVPLWWHUVVXFKDVEDVHVWDWLRQVIRUUDGLR FHOOXODUFRUGOHVV WHOHSKRQHVDQGODQG
mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with
DFFXUDF\7RDVVHVVWKHHOHFWURPDJQHWLFHQYLURQPHQWGXHWRÂż[HG5)WUDQVPLWWHUVDQHOHFWURPDJQHWLFVLWHVXUYH\
VKRXOGEHFRQVLGHUHG,IWKHPHDVXUHGÂżHOGVWUHQJWKLQWKHORFDWLRQLQZKLFKWKH'5,'LVXVHGH[FHHGVWKH
applicable RF compliance, the DR-ID 1200 should be observed to verify normal operation. If abnormal performance
is observed, additional measures may be necessary, such as reorienting or relocating the DR-ID 1200.
E 2YHUWKHIUHTXHQF\UDQJHN+]WR0+]ÂżHOGVWUHQJWKVKRXOGEHOHVVWKDQ9P
FDR D-EVO II Operation Manual
897N120339A
1-15
Table 4
Recommended separation distances between
3RUWDEOHDQGPRELOH5)FRPPXQLFDWLRQVHTXLSPHQWDQGWKH'5,'
The DR-ID 1200 is intended for use in the electromagnetic environment in which radiated RF disturbances are
controlled.
The customer or the user of the DR-ID 1200 can help prevent electromagnetic interference by maintaining a
minimum distance between portable and mobile RF communications equipment (transmitters) and the DR-ID 1200 as
recommended below, according to the maximum output power of the communications equipment.
For Safe Operation
Rated maximum output
power of transmitter
0.01
0.1
10
100
6HSDUDWLRQGLVWDQFHDFFRUGLQJWRIUHTXHQF\RIWUDQVPLWWHU
150 kHz to 80 MHz
d = 1.2
0.12
0.38
1.2
3.8
12
80 MHz to 800 MHz
d = 1.2
0.12
0.38
1.2
3.8
12
800 MHz to 2.5 GHz
d = 2.3
0.23
0.73
2.3
7.3
23
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres
(m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output
power rating of the transmitter in watts (W) according to the transmitter manufacturer.
127( $W0+]DQG0+]WKHVHSDUDWLRQGLVWDQFHIRUWKHKLJKHUIUHTXHQF\UDQJHDSSOLHV
127( 7KHVHJXLGHOLQHVPD\QRWDSSO\LQDOOVLWXDWLRQV
(OHFWURPDJQHWLFSURSDJDWLRQLVDIIHFWHGE\DEVRUSWLRQDQGUHÀHFWLRQIURPVWUXFWXUHVREMHFWVDQGSHRSOH
1-16
FDR D-EVO II Operation Manual
897N120339A
1.5 3UHFDXWLRQVLQ8VLQJWKH)'5'(92 II
This section describes the precautions in using the FDR D-EVO II.
 +DQGOLQJ
For Safe Operation
+DQGOHWKHÀDWSDQHOVHQVRUFDUHIXOO\VLQFHWKH\DUH
manufactured with precision.
,IWKHÀDWSDQHOVHQVRURUWKH6(FRPPXQLFDWLRQFDEOHLVKLWRU
dropped or is subjected to severe shock, it may be malfunction.
Be aware of dropping the devices could result in injury or
device breakage also may cause injury.
,IWKHIURQWDQGUHDURIWKHÀDWSDQHOVHQVRUDUHVXEMHFWWR
impact by a projection, it may be damaged.
'RQRWDSSO\VWURQJSUHVVXUHRQWRWKHÀDWSDQHOVHQVRU
,IDSSOLHGWKHÀDWSDQHOVHQVRUGHIRUPVDQGWKHZDWHUSURRI
function may be compromised.
Do not pull the SE communication cable.
$OVRGRQRWSXOOWKHÀDWSDQHOVHQVRUZLWKVRPHWKLQJFDXJKWE\
the cable.
Make sure that the cable is not trapped under the wheels of a
stretcher or wheelchair.
In addition, be careful not to catch the cable when using or
storing it.
2WKHUZLVHWKHFDEOHZLOOEHGDPDJHGFDXVLQJÂżUHHOHFWULF
shock or communication failure.
'RQRWKROGWKHÀDWSDQHOVHQVRULQRQHKDQGZKHQFDUU\LQJLW
Hold it in both the hands or under the arm.
:KHQFDUU\LQJRUVWRULQJWKHÀDWSDQHOVHQVRUUHPRYHWKH
battery pack from it.
If a seal that covers a screw peels from the side surface of the
ÀDWSDQHOVHQVRUFRQWDFWD)8-,),/0GHDOHU,IWKHVHDOLVQRW
attached, artifacts caused by discharge of static electricity may
appear.
To ensure optimal image quality, it is recommended that you do
QRWXVHWKHÀDWSDQHOVHQVRUQHDUGHYLFHV PRWRUWUDQVIRUPHU
switching supply, etc.) that generate electromagnetic noise.
To ensure optimal image quality, it is recommended that you do
not place the cables (power cable, communication cable, etc.)
of the equipment near devices (motor, transformer, switching
supply, etc.) that generate electromagnetic noise and their
cables.
0DNHVXUHWKDWQROLTXLGHQWHUVWKHÀDWSDQHOVHQVRUIURP
around the battery section. In addition, when attaching the
battery pack, make sure that the waterproof packing attached
WRWKHFRQQHFWRUWHUPLQDORIWKHÀDWSDQHOVHQVRULVDOLJQHG
SURSHUO\2WKHUZLVHWKHÀDWSDQHOVHQVRUPD\EHGDPDJHG
FDR D-EVO II Operation Manual
897N120339A
1-17
Do not use a multiple tap connector or extension cable for
powering the devices constituting the system.
8SWR¿YHÀDWSDQHOVHQVRUVFDQEHFRQQHFWHG,I\RXLQWHQG
WRXVHVL[RUPRUHÀDWSDQHOVHQVRUVRQO\WKH¿UVW¿YHWKDW
were connected to the image processing unit can be used.
)RUWKLVUHDVRQZKHQVL[RUPRUHÀDWSDQHOVHQVRUVDUH
registered, be careful not to use a wrong one, as you may
FRQIXVHZKLFKÀDWSDQHOVHQVRULVFRQQHFWHG
%HIRUHPDNLQJDQH[SRVXUHPDNHVXUHWKDWWKHÀDWSDQHO
VHQVRULGHQWL¿FDWLRQODPSRQWKHÀDWSDQHOVHQVRUWREH
used and the panel icon selected on the screen of the image
processing unit are the same color.
For Safe Operation
:KHQDÀDWSDQHOVHQVRULVFRPPXQLFDWLQJZLWKDSRZHU
supply unit, docking stand or access point in a room, if the
ÀDWSDQHOVHQVRULVPRYHGWRDQRWKHUURRPZKHUHWKHUHLV
another power supply unit, docking stand or access point,
FRPPXQLFDWLRQEHWZHHQWKHÀDWSDQHOVHQVRUDQGWKH
GHYLFHLQWKHÂżUVWURRPPD\VWLOOEHHVWDEOLVKHG7RHVWDEOLVK
FRPPXQLFDWLRQEHWZHHQWKHÀDWSDQHOVHQVRUDQGDGHYLFH
LQWKHVHFRQGURRPFRQQHFWWKHÀDWSDQHOVHQVRUWRWKH
device with the cable or insert it into the docking stand. The
ÀDWSDQHOVHQVRULVUHFRJQL]HGDQGZLUHOHVVFRPPXQLFDWLRQ
becomes available.
'RQRWSODFHWKHFDEOHWHUPLQDORQWKHÀRRUDVGRLQJVRPD\
cause infection.
Also, clean the cable and the terminal periodically.
'RQRWLQVHUWWKHÀDWSDQHOVHQVRULQWRD&5UHDGHUXQLW
1.5.2 Before Exposure
The use of an air-conditioner may dramatically changes the temperature of the room where the
system is installed. This may cause dew condensation on the system, resulting in quality problems.
When an air-conditioner is used, change the temperature gradually to avoid temperature variation
in order not to cause dew condensation.
,IDQH[SRVXUHLVPDGHZLWKWKHIURQWDQGUHDURIWKHÀDWSDQHO
sensor facing the other way round, not only the re-exposure
is required but electric parts of inside the equipment may be
damaged.
Exposure plane of the
flat panel sensor
1-18
FDR D-EVO II Operation Manual
897N120339A
 'XULQJ([SRVXUH
Before making an exposure, make sure that exposure conditions most appropriate for this system
are set.
Do not apply an excessive force to the exposure plane.
7KHVHQVRULQVLGHWKHÀDWSDQHOVHQVRUPD\EHGDPDJHG
and it may not be possible to make an exposure properly.
For Safe Operation

(QWLUHVXUIDFHORDG'5,'6('5,'6('5,'6(
DQG'5,'6(
310kg (683.6 lb)
/RFDOORDG'5,'6('5,'6('5,'6(DQG
'5,'6(
160kg (352.8 lb) / ø40mm (1.6 in.)
%DVHGRQ)8-,),/0PHDVXUHPHQWVSHFLÂżFDWLRQV
8VHWKHÀDWSDQHOVHQVRURQDÀDWÀRRURUSODWIRUP
When an excessive force is applied to the unit when it is tilted, the
VHQVRULQVLGHWKHÀDWSDQHOVHQVRUPD\EHGDPDJHG
Do not place a metal plate, etc., which blocks radio waves, before
WKHDQWHQQD2WKHUZLVHGDWDPD\QRWEHVHQWFRUUHFWO\IURPWKHÀDW
panel sensor.
Antenna
Antenna
FDR D-EVO II Operation Manual
897N120339A
1-19
:KHQWKH6(FRPPXQLFDWLRQFDEOHLVFRQQHFWHGWRWKHÀDWSDQHOVHQVRUWRPDNHDQH[SRVXUH
on a bed, follow the precautions below. Otherwise a load may be applied locally to the SE
FRPPXQLFDWLRQFDEOHFRQQHFWRUVFDXVLQJGDPDJHWRWKHÀDWSDQHOVHQVRU
For Safe Operation
Make sure that the connector
does not protrude from the
edge of a bed
Do not place the connector
on a hard surface such as
the edge of a bed
Do not raise the flat
panel sensor by holding
only the connector
 'XULQJ&OHDQLQJ
To clean the outer surfaces, use a cleaning cloth tightly wrung out of commercially available ethanol
(or diluted neutral detergent).
CAUTIONS
  %HVXUHWRWXUQRIIWKHSRZHUEHIRUHFOHDQLQJHDFKSDUWRIWKHGHYLFH
Ɣ
Ɣ 'RQRWXVHDQH[FHVVLYHDPRXQWRIHWKDQRO RUQHXWUDOGHWHUJHQW DVGRLQJVRPD\DOORZWKH
OLTXLGWRHQWHUIURPWKHJDSRQWKHRXWHUVXUIDFHVUHVXOWLQJLQWKHGDPDJHWRWKHÀDWSDQHO
sensor, or cause the labels to come off.
Ɣ 'RQRWXVHDVROYHQWVXFKDVWKLQQHURUEHQ]LQHDVLWFRUURGHVWKHRXWHUVXUIDFHV
Ɣ )RURWKHUDYDLODEOHGLVLQIHFWDQWVFRQVXOWRXURI¿FLDOGHDOHU
 6WRUDJH
:KHQWKHÀDWSDQHOVHQVRUDQGWKHLPDJHSURFHVVLQJXQLWDUHQRWLQXVHVWRUHWKHPLQDSODFH
where they do not fall or drop.
1-20
FDR D-EVO II Operation Manual
897N120339A
1.5.6 Precautions Related to the Load Applied to the Flat
Panel Sensor
,IH[FHVVLYHORDGLVDSSOLHGWRWKHÀDWSDQHOVHQVRUXVHLWRQDÀDWÀRRURUSODWIRUP
When making an exposure for the patient in a wheelchair or adjustable bed or on a stretcher, the
ÀDWSDQHOVHQVRUPD\EHGHIRUPHG VOLJKWO\ZDUSHG 
For Safe Operation
Flat panel sensor
Flat panel sensor
,QFDVHWKDWWKHÀDWSDQHOVHQVRULVGHIRUPHGPDNHVXUHWKDW;UD\LPDJHVDUHQRWDGYHUVHO\
DIIHFWHGEHIRUHFRQWLQXLQJWKHXVHRIWKHÀDWSDQHOVHQVRU
The precautions below must also be observed when making an exposure.
 ‡'RQRWKDYHWKHSDWLHQWVWDQGRQWKHÀDWSDQHOVHQVRU
 ‡'RQRWSODFHWKHKDUGGHYLFHVVXFKDVVSLQHERDUGRQWKHÀDWSDQHOVHQVRU
([FHVVLYHORDGLVDSSOLHGORFDOO\DQGWKHÀDWSDQHOVHQVRUPD\EHGDPDJHG
Spine board
Flat panel sensor
(YHQZKHQWKHÀDWSDQHOVHQVRULVXVHGRQDÀDWÀRRURUSODWIRUPLWPD\EHGDPDJHGLIWKHDSSOLHG
load exceeds the limit.
FDR D-EVO II Operation Manual
897N120339A
1-21
1.5.7 Radio Waves
:LUHOHVVVSHFL¿FDWLRQVIRUWKHÀDWSDQHOVHQVRUDQGDFFHVVSRLQWDUHDVIROORZV
)ODWSDQHOVHQVRU
$FFHVVSRLQW RSWLRQDO
:LUHOHVVVSHFLILFDWLRQ
,(((Q
,(((Q
7UDQVPLWIUHTXHQF\
*+]
*+]
0RGXODWLRQ
OFDM
OFDM
)UHTXHQF\WROHUDQFH
“SSP
“SSP
'DWDWUDQVIHUUDWH
0ESV
0ESV
7UDQVIHUSRZHU
G%PRUOHVV
G%PRUOHVV
For Safe Operation
)RUZLUHOHVVVSHFL¿FDWLRQVRIWKHLPDJHSURFHVVLQJXQLWVHH³'5,'&/2SHUDWLRQ0DQXDO´
CAUTIONS
Ɣ Radio waves available outdoors vary, depending on the country where the system is used.
(For U.S.)
Radio waves in the 5.2GHz frequency band can be used indoors only.
When radio waves in the 5.3GHz and 5.6GHz frequency bands are selected, the DFS function
will operate.
Ɣ When the FDR D-EVO II and any other wireless equipment are operating on the same
frequency channel in a hospital, it may take time to show an image on the image processing
unit monitor.
CAUTIONS
7KHDYDLODEOHVFLHQWLÂżFHYLGHQFHGRHVQRWVKRZWKDWDQ\KHDOWKSUREOHPVDUHDVVRFLDWHGZLWK
using low power wireless devices. There is no proof, however, that these low power wireless
devices are absolutely safe. Low power Wireless devices emit low levels of radio frequency
energy (RF) in the microwave range while being used. Whereas high levels of RF can produce
health effects (by heating tissue), exposure of low-level RF that does not produce heating effects
causes no known adverse health effects. Many studies of low-level RF exposures have not found
any biological effects. Some studies have suggested that some biological effects might occur,
EXWVXFKÂżQGLQJVKDYHQRWEHHQFRQÂżUPHGE\DGGLWLRQDOUHVHDUFK'5,'6('5,'6(
'5,'6('5,'6(KDVEHHQWHVWHGDQGIRXQGWRFRPSO\ZLWK)&&,&UDGLDWLRQH[SRVXUH
OLPLWVVHWIRUWKIRUDQXQFRQWUROOHGHQYLURQPHQWDQGPHHWVWKH)&&UDGLRIUHTXHQF\ 5) ([SRVXUH
*XLGHOLQHVDQG566RIWKH,&UDGLRIUHTXHQF\ 5) ([SRVXUHUXOHV
/HVFRQQDLVVDQFHVVFLHQWLÂżTXHVGRQWQRXVGLVSRVRQVQÂśRQWPLVHQpYLGHQFHDXFXQSUREOqPHGH
VDQWpDVVRFLpjOÂśXVDJHGHVDSSDUHLOVVDQVÂżOjIDLEOHSXLVVDQFH1RXVQHVRPPHVFHSHQGDQWSDV
HQPHVXUHGHSURXYHUTXHFHVDSSDUHLOVVDQVÂżOjIDLEOHSXLVVDQFHVRQWHQWLqUHPHQWVDQVGDQJHU
/HVDSSDUHLOVVDQVÂżOjIDLEOHSXLVVDQFHpPHWWHQWXQHpQHUJLHUDGLRpOHFWULTXH 5) WUqVIDLEOHGDQV
OHVSHFWUHGHVPLFURRQGHVORUVTXÂśLOVVRQWXWLOLVpV$ORUVTXÂśXQHGRVHpOHYpHGH5)SHXWDYRLUGHV
HIIHWVVXUODVDQWp HQFKDXIIDQWOHVWLVVXV OÂśH[SRVLWLRQjGHIDLEOHV5)TXLQHSURGXLVHQWSDVGH
FKDOHXUQÂśDSDVGHPDXYDLVHIIHWVFRQQXVVXUODVDQWp'HQRPEUHXVHVpWXGHVRQWpWpPHQpHV
VXUOHVH[SRVLWLRQVDX[5)IDLEOHVHWQÂśRQWGpFRXYHUWDXFXQHIIHWELRORJLTXH&HUWDLQHVpWXGHV
RQWVXJJpUpTXÂśLOSRXYDLW\DYRLUFHUWDLQVHIIHWVELRORJLTXHVPDLVFHVUpVXOWDWVQÂśRQWSDVpWp
FRQÂżUPpVSDUGHVUHFKHUFKHVVXSSOpPHQWDLUHV'5,'6('5,'6('5,'6('5,'
6(DpWpWHVWpHWMXJpFRQIRUPHDX[OLPLWHVGÂśH[SRVLWLRQDX[UD\RQQHPHQWVpQRQFpHVSRXU
XQHQYLURQQHPHQWQRQFRQWU{OpHWUHVSHFWHOHVUqJOHVOHVUDGLRpOHFWULTXHV 5) GHOD)&&OLJQHV
GLUHFWULFHVGÂśH[SRVLWLRQHWGÂśH[SRVLWLRQDX[IUpTXHQFHVUDGLRpOHFWULTXHV 5) &15GHOÂś,&
1-22
FDR D-EVO II Operation Manual
897N120339A
 %DWWHU\3DFN6WDWXV,QGLFDWRU
7KHVWDWXVDQGRSHUDEOHWLPHRIWKHEDWWHU\SDFNXVHGIRUWKHÀDWSDQHOVHQVRUDUHVKRZQE\WKH
exposure unit battery indicator in the connected devices status at the lower right of the image
processing unit’s display.
The battery pack status indicator shows the remaining capacity of the battery pack. Each icon is
described below.
For details of the connected devices status, see the “Console Advance (DR-ID 300CL) Reference Guide”.
For Safe Operation
5HDG\IRUH[SRVXUH
5HDG\IRUH[SRVXUH
5HDG\IRUH[SRVXUH
(The remaining battery capacity is
low. Charge the battery pack.)
1RWUHDG\IRUH[SRVXUH
&KHFNWKHRSHUDEOHWLPHRQWKHLPDJHSURFHVVLQJXQLW¶VGLVSOD\ZKHQWKHÀDWSDQHOVHQVRULVLQXVH
Note that the displayed time differs, depending on the mode being used.
FDR D-EVO II Operation Manual
897N120339A
1-23
1.6 Locations of Labels and Signs
/RFDWLRQVRIODEHOVDQGVLJQVDIÂż[HGWRWKH)'5'(92IIDQGWKHUHOHYDQWVDIHW\VLJQVDUHVKRZQ
EHORZ
1.6.1 Locations of Labels
)ODWSDQHOVHQVRU '5,'6(
)ODWSDQHOVHQVRU '5,'6(
For Safe Operation
Serial Number Label
Serial Number Label
DR-ID 1201SE
Radio Law Certification Label
DR-ID 1202SE
Radio Law Certification Label
Battery Cover Label
Battery Cover Label
DR-ID 1201SE Identification Label
DR-ID 1202SE Identification Label
([SRVXUHSODQH!
([SRVXUHSODQH!
)ODWSDQHOVHQVRU '5,'6(
)ODWSDQHOVHQVRU '5,'6(
Serial Number Label
Serial Number Label
DR-ID 1211SE
Radio Law Certification Label
DR-ID 1212SE
Radio Law Certification Label
Battery Cover Label
Battery Cover Label
DR-ID 1211SE Identification Label
DR-ID 1212SE Identification Label
([SRVXUHSODQH!
([SRVXUHSODQH!
Main switch/
power status LED
&RQWUROFDELQHW '5,'0&
,IWKHFRQWUROFDELQHWLVQRWLQFOXGHGLQWKHV\VWHPWKH'5,'0&LGHQWLÂżFDWLRQODEHOLVSODFHGRQWKH&'
FDVHRIWKHVRIWZDUHIRUWKHFRQWUROFDELQHW
1-24
FDR D-EVO II Operation Manual
897N120339A
Do Not Step On
This Surface label
For the types of connectable
FDEOHVFRQVXOWRXURIÂżFLDO
dealer or FUJIFILM
Representative
DR-ID 1200MP
Caution Label 1
DR-ID 1200PU
System Label
Pour en savoir plus sur les
types de câbles connectables,
contactez notre revendeur agrĂŠĂŠ
ou notre reprĂŠsentant FUJIFILM.
DR-ID 1200MP
Caution Label 2
DR-ID 1200PU
Rating Label
For Safe Operation
Power supply unit (DR-ID 1200MP)
Do Not Step On This Surface label
DR-ID 1200DU
System Label
DR-ID 1200DS
Caution Label 1
DR-ID 1200DU
Rating Label
DR-ID 1200DS
Caution Label 2
Docking stand (DR-ID 1200DS)
For the types of connectable cables,
FRQVXOWRXURIÂżFLDOGHDOHU
or FUJIFILM Representative
Pour en savoir plus sur les types de câbles
connectables, contactez notre revendeur
agrĂŠĂŠ ou notre reprĂŠsentant FUJIFILM.
Battery Charger Rating Label
Battery pack
Rating Label
AC Adapter Rating Label
Battery Charger (optional)
Access Point
Product Label
Battery pack (optional)
Access Point
Radio Law Certification Label
Access point (optional)
For details on the locations of labels for the image processing unit, see the “Console Advance (DR-ID 300CL)
Operation Manual”.
FDR D-EVO II Operation Manual
897N120339A
1-25
1.6.2 DR-ID 1200
For Safe Operation
DR-ID 1201SE Identification Label
DR-ID 1202SE Identification Label
DR-ID 1211SE Identification Label
DR-ID 1212SE Identification Label
Battery Cover Label
Do Not Step On This Surface label
DR-ID 1201SE/DR-ID 1202SE/
DR-ID 1211SE/DR-ID 1212SE
Radio Law Certification Label
SN
Serial Number Label
DR-ID 1200MC Identification Label
1-26
FDR D-EVO II Operation Manual
897N120339A
DR-ID 1200MC Identification Label
(for the system without the DR-ID 1200MC)
1
Battery Charger Rating Label
Access Point Product Label
(for Europe)
Access Point Product Label
(for North America)
For Safe Operation
Battery Pack Rating Label
AC Adapter (Battery Charger)
Rating Label
Access Point
Radio Law Certification Label
For details on the labels of the image processing unit, see the “Console Advance (DR-ID 300CL) Operation
Manual”.
1.6.3 DR-ID 1200PU
DR-ID 1200MP
Caution Label 1
DR-ID 1200PU System Label
DR-ID 1200PU Rating Label
DR-ID 1200MP
Caution Label 2
1.6.4 DR-ID 1200DU
DR-ID 1200DS
Caution Label 1
DR-ID 1200DU System Label
DR-ID 1200DU Rating Label
DR-ID 1200DS
Caution Label 2
FDR D-EVO II Operation Manual
897N120339A
1-27
1.6.4 Safety and Other Symbols
The following safety symbols are used in the labels or on its body.
Symbol
Description
This symbol indicates compliance of the equipment with Directive 93/42/EEC.
This symbol indicates compliance of the equipment with Directive 93/42/EEC.
7KLVV\PEROLQGLFDWHVWKDWWKHHTXLSPHQWLVFODVVLÂżHGDV&ODVVHTXLSPHQWLQWKH5 77(
Directive.
For Safe Operation
Caution (See “1.6.1 Locations of Labels” (page 1-24).)
OFF (To indicate disconnection from the mains, at least for mains switches or their positions,
and all those cases where safety is involved.)
ON (To indicate connection to the mains, at least for mains switches or their positions, and all
those cases where safety is involved.)
Protective earth (ground)
Alternating current
This symbol indicates that the equipment is a Type B Applied Part.
Ready (To indicate the machine is ready for operation.)
Electric energy
General mandatory action sign
This symbol indicates that this product is not to be disposed of with your household waste,
according to the WEEE Directive (2002/96/EC) and your national law. This product should be
handed over to a designated collection point.
Improper handling of this type of waste could have a possible negative impact on the environment
and human health due to potentially hazardous substances that are generally associated with EEE.
At the same time, your cooperation in the correct disposal of this product will contribute to the
effective usage of natural resources.
)RUPRUHLQIRUPDWLRQDERXWZDVWHSOHDVHFRQWDFWRXURIÂżFLDOGHDOHURU)8-,),/05HSUHVHQWDWLYH
Year of manufacture
Environmentally Friendly Use Period (EFUP)
Caution for local load (See “1.5.3 During Exposure” (page 1-19).) /
'RQRWGURSWKHÀDWSDQHOVHQVRUWRWKHXVHUSDWLHQW
Entire surface load
This symbol includes RF transmitters or indicates equipment that intentionally applies RF
electromagnetic energy for diagnosis or treatment.
Refer to Instruction Manual/Booklet
No stepping on surface
1-28
FDR D-EVO II Operation Manual
897N120339A
1.6.5 Symboles de sĂŠcuritĂŠ et autres
Les symboles de sécurité suivants sont utilisés sur les étiquettes ou sur le corps de l’équipement.
Symbole
Description
Ce symbole indique la conformité de l’équipement à la directive 93/42/CEE.
Ce symbole indique la conformité de l’équipement à la directive 93/42/CEE.
&HV\PEROHLQGLTXHTXHOÂśpTXLSHPHQWDSSDUWLHQWjODFDWpJRULHGHODFODVVLÂżFDWLRQGHOD
GLUHFWLYH5 77(
For Safe Operation
Attention (Voir ÂŤ 1.6.1 Emplacement des ĂŠtiquettes Âť (page 1-24).)
HORS TENSION (Pour indiquer une déconnexion de l’alimentation secteur, au moins au niveau des
interrupteurs secteurs ou leur position, et tous les cas dans lesquels la sĂŠcuritĂŠ est en jeu.)
SOUS TENSION (Pour indiquer une connexion à l’alimentation secteur, au moins au niveau des
interrupteurs secteurs ou leur position, et tous les cas dans lesquels la sĂŠcuritĂŠ est en jeu.)
Protection via mise Ă  la terre (masse)
Courant alternatif
Ce symbole indique que l’équipement est une pièce appliquée de type B.
PrĂŞt (Pour indiquer que la machine est prĂŞte Ă  ĂŞtre utilisĂŠe.)
Énergie électrique
Symbole général d’action obligatoire
Ce symbole indique que ce produit ne doit pas ĂŞtre mis au rebut avec les dĂŠchets mĂŠnagers,
conformĂŠment Ă  la directive DEEE (2002/96/CE) et Ă  la lĂŠgislation nationale en vigueur. Ce produit
doit ĂŞtre remis Ă  un centre de collecte appropriĂŠ.
Une manipulation incorrecte de ce type de déchet peut avoir un impact négatif sur l’environnement
et sur la santĂŠ humaine, en raison des substances potentiellement dangereuses gĂŠnĂŠralement
associĂŠes aux EEE.
Votre coopĂŠration pour la mise au rebut correcte de ce produit contribuera en outre Ă  une utilisation
HIÂżFDFHGHVUHVVRXUFHVQDWXUHOOHV
Pour en savoir plus sur les dĂŠchets, contactez notre revendeur agrĂŠĂŠ ou notre reprĂŠsentant FUJIFILM.
AnnĂŠe de fabrication
Attention relative à une charge placÊe de façon localisÊe /
Ne faites pas tomber le détecteur à panneau plat sur l’utilisateur/le patient
Charge sur l’intégralité de la surface
Ce symbole inclut les ĂŠmetteurs RF ou indique un ĂŠquipement ĂŠmettant intentionnellement de
OÂśpQHUJLHpOHFWURPDJQpWLTXH5)jGHVÂżQVGHGLDJQRVWLFRXGHWUDLWHPHQW
Consultez le mode d’emploi
Ne montez pas sur la surface
FDR D-EVO II Operation Manual
897N120339A
1-29
1.7 Installation Conditions
 'HÂżQLWLRQRI3DWLHQW(QYLURQPHQW
)RUWKHSURGXFWVWKDWFDQEHLQVWDOOHGLQSDWLHQWHQYLURQPHQWVHH³6\VWHP&RQ¿JXUDWLRQ´
(page 2-1).
CAUTIONS
For Safe Operation
,QWKH;UD\URRPGRQRWLQVWDOOWKHSRZHUVXSSO\XQLWFRQWUROFDELQHWGRFNLQJVWDQGDFFHVV
SRLQWLPDJHSURFHVVLQJXQLWDQGEDWWHU\FKDUJHU RSWLRQDO LQDUHDVZKHUHWKHXVHUFRXOG
easily trip over them. Falls could result in injury.
(8 .5m
.2
ft)
Ĺś %HGLQDSDWLHQWURRPRUEHGW\SHUDGLRJUDSKLFH[DPLQDWLRQVWDQG
2.5m
(8.2 ft)
2.5m
(8.2 ft)
2.5m
(8.2 ft)
Ĺś 8SULJKWW\SHUDGLRJUDSKLFH[DPLQDWLRQVWDQG
(8 .5m
.2
ft)
2.5m
(8.2 ft)
2.5m
(8.2 ft)
1-30
FDR D-EVO II Operation Manual
897N120339A
2.5m
(8.2 ft)
1.7.2 Installation Precautions
Ĺś 8VLQJLQDQRSHQVSDFH
,QVWDOOWKHÀDWSDQHOVHQVRUWKHDFFHVVSRLQWDQGWKHLPDJHSURFHVVLQJXQLWDWDGLVWDQFHRIOHVV
than 10m (32.8 ft) from each other. If any distance is over 10m (32.8 ft), a wireless communication
error may occur.
Ĺś 8VLQJLQDQ;UD\URRP
The access point should be installed in the X-ray room.
For Safe Operation
If the access point is not installed properly, wireless communication may become unstable.
If this happens, the messages below may appear.
These messages are only examples.
Example 1
Panel communication error
Example 2
Connection to X-ray unit has been disconnected.
 3UHFDXWLRQVIRU,QVWDOOLQJWKH$FFHVV3RLQW 2SWLRQDO
Install the optional access point in a place where the operation is not hindered.
When the access point is installed onto a personal computer, be sure that the label attached on the
access point does not face the front side.
In addition, install the access point in an appropriate place to prevent it from colliding with a moving mobile X-ray
unit. If any impact is applied to the optional access point, it may be damaged.
FDR D-EVO II Operation Manual
897N120339A
1-31
1
For Safe Operation
1-32
FDR D-EVO II Operation Manual
897N120339A
Chapter 2
 \VWHP&RQILJXUDWLRQ
(Product Overview)
2.1 FDR D-EVO II
 6\VWHP&RQÂżJXUDWLRQ
(When the optional access point is used)
DIGITAL RADIOGRAPHY DR-ID 1200
6\VWHP&RQILJXUDWLRQ 3URGXFW2YHUYLHZ
PANEL UNIT DR-ID 1200PU
DOCKING UNIT DR-ID 1200DU
Flat panel
sensor
Flat panel
sensor
Power supply unit DR-ID 1200MP
Docking stand DR-ID 1200DS
Image processing unit DR-ID 300CL*1, *3
Access point
Battery charger
Hub
Image processing unit of other
digital radiography system DR-ID 300CL
(When an access point installed in the hospital is used)
DIGITAL RADIOGRAPHY DR-ID 1200
PANEL UNIT DR-ID 1200PU
Flat panel
sensor
Power supply unit DR-ID 1200MP
DOCKING UNIT DR-ID 1200DU
Flat panel
sensor
Docking stand DR-ID 1200DS
Image processing unit DR-ID 300CL*3
Battery charger
Control cabinet DR-ID 1200MC*2
Access point
Hub
Image processing unit of other
digital radiography system DR-ID 300CL
FDR D-EVO II Operation Manual
897N120339A
2-1
• The products in
can be installed in patient environment.
However, the image processing unit cannot be installed while it is being charged.
• The FDR D-EVO II consists of the panel unit DR-ID 1200PU or docking unit DR-ID 1200DU, the
control cabinet DR-ID 1200MC and the image processing unit.
‡7KHSDQHOXQLW'5,'38FRQVLVWVRIWKHÀDWSDQHOVHQVRU'5,'6('5,'6(
DR-ID 1211SE and DR-ID 1212SE, and the power supply unit DR-ID 1200MP.
• The panel unit DR-ID 1200PU can be operated in conjunction with the X-ray equipment, and it can
be used for exposures in wired mode.
‡7KHGRFNLQJXQLW'5,''8FRQVLVWVRIWKHÀDWSDQHOVHQVRU'5,'6('5,'6(
DR-ID 1211SE and DR-ID 1212SE, and the docking stand DR-ID 1200DS.
• With the docking unit DR-ID 1200DU, the exposure ready status can be displayed with the lamp
RQWKHGRFNLQJVWDQG,QDGGLWLRQWKHÀDWSDQHOVHQVRUWREHXVHGIRUH[SRVXUHFDQEHLGHQWL¿HG
with the lamp indication on the docking stand.
‡7KHLPDJHSURFHVVLQJXQLW'5,'&/LVFRQ¿JXUHGE\LQVWDOOLQJLPDJHSURFHVVLQJVRIWZDUHRQ
a commercially available personal computer conforming to IEC 60950-1 or equivalent.
‡8SWR¿YHÀDWSDQHOVHQVRUVFDQEHFRQQHFWHG
‡:KHQWKH'5,'38LVXVHGXSWRWZRÀDWSDQHOVHQVRUVFDQEHFRQQHFWHGWRRQHSRZHU
VXSSO\XQLWLQZLUHGFRPPXQLFDWLRQPRGH8SWRWZRSRZHUVXSSO\XQLWFDQEHXVHG:KHQWKHÀDW
panel sensors are used with three to four different techniques, two power supply units are required.
‡:KHQWKH'5,''8LVXVHGRQO\RQHÀDWSDQHOVHQVRUVFDQEHFRQQHFWHGWRRQHGRFNLQJ
stand in wired communication mode. Up to three docking stand can be used.
• When the DR-ID 1200DU and a mobile X-ray unit are used, power to the access point is supplied by
connecting it to the image processing unit DR-ID 300CL.
System Configuration (Product Overview)
*1 The software for the control cabinet is installed on the image processing unit (DR-ID 300CL).
'HSHQGLQJRQWKHFRQÂżJXUDWLRQWKHFRQWUROFDELQHW '5,'0& PD\QRWEHLQFOXGHGLQ
the system. If not included, the software for the control cabinet can be installed on the image
processing unit (DR-ID 300CL).
)RUGHWDLOVSHFLÂżFDWLRQRILPDJHSURFHVVLQJXQLWSOHDVHUHIHUWRÂł'5,'&/2SHUDWLRQ
Manual”.
*3 When the image processing unit (DR-ID 300CL) is used in patient environment, run the notebook
computer on battery power.
2-2
FDR D-EVO II Operation Manual
897N120339A
2.1.2 Features of the FDR D-EVO II
This section describes the main features of the FDR D-EVO II.
 /LJKWZHLJKWWKLQDQGURXQGLVKGHVLJQRIWKHÀDWSDQHOVHQVRUIDFLOLWDWHVOLIWLQJDQG
enhances operability, for example, when it is set under a patient lying on a bed.
2 By utilizing FUJIFILM’s proprietary ISS (Irradiation Side Sampling) method, vapor
deposition technique of CsI scintillator, particle blend technique of GOS scintillator, and also
noise reduction IC, images with high sensitivity and high sharpness are obtained even in
low-density areas.
3 After an X-ray irradiation process is completed, the exposed image appears on the monitor
of the image processing unit in about one second at the shortest. In addition, since images
are compressed with our unique compression technology (CIP) during communication,
H[SRVXUHVFDQEHPDGHHIÂżFLHQWO\DWVKRUWLQWHUYDOV
 7KHÀDWSDQHOVHQVRUKDVVOHHSPRGHDQGH[WUDVOHHSPRGH7KLVSRZHUVDYLQJGHVLJQ
almost eliminates the need of replacing the battery pack. In addition, since a removable
battery pack is adopted, it can be replaced even if the battery runs down.
5 The docking stand and the optional battery charger assist smooth exposure operations.
The system can be used even in an emergency since only 3 minutes of charge time are
required to make about 30 exposures.
 8SWRLPDJHVFDQEHVWRUHGWHPSRUDULO\LQWKHPHPRU\RIWKHÀDWSDQHOVHQVRU
The memory exposure mode can be activated easily by operating the button on the back of
WKHÀDWSDQHOVHQVRU(YHQLIWKHLPDJHSURFHVVLQJXQLWLVQRWDYDLODEOHH[SRVXUHVFDQEH
PDGHRQO\E\XVLQJWKHÀDWSDQHOVHQVRU
7 Extended Image Readout enables a long exposure for up to ten seconds.
 7KHÀDWSDQHOVHQVRUFDQEHXVHGFOHDQO\VLQFHDOOVXUIDFHVKDYHEHHQFRDWHGZLWKDQ
antibacterial agent.
 6LQFHWKHH[WHUQDOGLPHQVLRQVDQGWKLFNQHVVRIWKHÀDWSDQHOVHQVRUDUHWKHVDPHDVWKRVH
RIH[LVWLQJFDVVHWWHIRUJHQHUDOH[SRVXUH FRPSOLDQWZLWK,62 WKHÀDWSDQHOVHQVRU
can be loaded onto the exposure stand that has been used. In addition, since operation on
EDWWHU\SRZHUDQGZLUHOHVVFRPPXQLFDWLRQDUHDYDLODEOHRQHÀDWSDQHOVHQVRUFDQEHXVHG
for multiple devices such as upright type and supine-position type radiography devices.
7KHÀDWSDQHOVHQVRUKDVWKH;UD\DXWRPDWLFGHWHFWLRQIXQFWLRQ 6PDUW6ZLWFK 
 :LWKWKLVIXQFWLRQWKHÀDWSDQHOVHQVRUGHWHFWVHYHQDVPDOODPRXQWRI;UD\SUHFLVHO\WR
start an exposure without connecting it to the X-ray device.
11 By using a notebook computer as the image processing unit, and also by using the optional
access point, the need of carrying cables is eliminated and the system can be used for
rounds.
In addition, exposures can also be made outdoors depending on the frequency band of
radio wave.
8SWRÀDWSDQHOVHQVRUVFDQEHUHJLVWHUHG$PRQJWKHUHJLVWHUHGÀDWSDQHOVHQVRUVXS
WR¿YHÀDWSDQHOVHQVRUVFDQEHXVHG
2QHDFKVLGHRIWKHÀDWSDQHOVHQVRUWKHUHLVDQ/('VKRZLQJWKHFHQWHUSRVLWLRQ7KH
FRORURIWKLV/('FDQEHVHOHFWHGIURPDPRQJÂżYHFRORUV RUDQJHSXUSOHOLPH\HOORZEOXH
DQGSLQN :KHQPXOWLSOHÀDWSDQHOVHQVRUVDUHXVHGWKH\FDQEHLGHQWL¿HGZLWKWKHFRORU
of the LED.
In addition, the battery pack level can always be checked with the indicator LED on the
EDFNRIWKHÀDWSDQHOVHQVRU
6LQFHWKHÀDWSDQHOVHQVRUFDQEHVKDUHGZLWKPXOWLSOHV\VWHPVWKHQXPEHURIÀDWSDQHO
sensors can be optimized.
897N120339A
System Configuration (Product Overview)
FDR D-EVO II Operation Manual
2-3
2.2 Unit Names and the Functions
Unit names and the functions of the FDR D-EVO II are described below.
2.2.1 DR-ID 1200
Ĺś DR-ID 1200PU
* Exposure plane is shown in this figure.
Flat panel sensor identification lamp
Applied part
Sleep release/
memory exposure
mode start button
Battery pack
level indicator
System Configuration (Product Overview)
Sleep lamp
Memory exposure
mode status
Status lamp


Memory exposure mode start button
Flat panel sensor (DR-ID 1201SE, DR-ID 1202SE, DR-ID 1211SE and DR-ID 1212SE)
Power status LED
Main switch
Power supply unit (DR-ID 1200MP)
2-4
FDR D-EVO II Operation Manual
897N120339A
Name
Description
Flat panel sensor
The DR-ID 1201SE and DR-ID 1202SE incorporate a GOS indirect panel.
The DR-ID 1211SE and DR-ID 1212SE incorporate a CsI indirect panel.
Flat panel sensor
LGHQWLÂżFDWLRQODPS
7KHÀDWSDQHOVHQVRUFXUUHQWO\LQXVHLVLGHQWL¿HGE\WKHFRORURIWKLVODPS
The color of this lamp is selected from among lime yellow, blue, purple, orange and
SLQNDWWKHWLPHRILQVWDOODWLRQ,IWKHFRORULVQRWVSHFLÂżHGWKLVODPSLVOLWLQZKLWH
7KLVODPSRQWKHÀDWSDQHOVHQVRUFXUUHQWO\LQXVHLVOLWLQWKHVDPHFRORUDVWKH
panel icon selected on the display of the image processing unit.
Sleep lamp
This LED shows the sleep status.
(Blue)
Off
Sleep off or Sleep state
On
Extra sleep state
Sleep release/memory
exposure mode start button
Releases the extra sleep mode.
Memory exposure mode
start button
When this button is held pressed for 2 seconds while pressing the sleep release/
memory exposure mode start button, the memory exposure mode starts up.
The memory exposure mode can be started up when no exposure menu is
registered and calibration is not being performed.
Battery pack
level indicator
System Configuration (Product Overview)
:KHQWKHÀDWSDQHOVHQVRULVQRWRSHUDWHGIRUPLQXWHVLWLVSODFHGLQWKHVOHHS
mode.
Extra sleep mode, which can further save power, can also be set. To specify or
change the setting of sleep mode or extra sleep mode, contact a FUJIFILM dealer.
Memory exposure mode status
In the memory exposure mode, the number of exposed images or an error during the start-up
of memory exposure mode is displayed.
Name
Status lamp
Description
Indicates the equipment status by LEDs.
READY
READY
POWER
ERROR
LINK
(Green)
On
Blinks for 1.0
second
Off
On
(Blue)
POWER
(The power on/off state of the
Off
ÀDWSDQHOVHQVRULVGLVSOD\HG 
Blinks for 1.0
second
ERROR
(Orange)
Off
On
LINK
(White)
Off
Exposure possible
During exposure sequence
Not ready
Power ON
Power OFF
Error occurred
Normal
Connected
Communication not possible.
* When the battery pack is not attached, all LEDs are off.
Power supply unit
(DR-ID 1200MP)
$GHYLFHVXSSO\LQJSRZHUWRWKHÀDWSDQHOVHQVRUDQGFRQQHFWLQJEHWZHHQWKH
ÀDWSDQHOVHQVRULPDJHSURFHVVLQJXQLWDQGFRQWUROFDELQHW
Main switch
6XSSOLHVWKHSRZHUWRWKHÀDWSDQHOVHQVRUDQGWKHLQVLGHRIWKHSRZHUVXSSO\
unit.
Power status LED
Displays ON/OFF of the power supply unit.
HINT
)RUGHWDLOVRQWKHÀDWSDQHOVHQVRULGHQWL¿FDWLRQODPSDQGEDWWHU\SDFNOHYHOLQGLFDWRUVHH³/DPS,QGLFDWLRQVRQ
the Flat Panel Sensor”.
FDR D-EVO II Operation Manual
897N120339A
2-5
Ĺś DR-ID 1200DU
Flat panel sensor
identification lamp
READY lamp
Status lamps
Mute switch
Main switch

Docking stand (DR-ID 1200DS)
System Configuration (Product Overview)
Name
Description
Docking stand
(DR-ID 1200DS)
6XSSOLHVWKHSRZHUWRWKHÀDWSDQHOVHQVRUDQGFRQQHFWVWKHÀDWSDQHOVHQVRU
and the image processing unit.
Main switch
6XSSOLHVWKHSRZHUWRWKHGRFNLQJVWDQGDQGWKHÀDWSDQHOVHQVRU
Status lamps
POWER
(Blue)
(The power on/off state of the
docking stand is displayed.).
POWER
LINK
LINK
Battery pack level indicator
(White)
Battery pack level indicator
On
Power ON
Off
Power OFF
On
Connected
(This lamp is lit when
communication with the control
cabinet is established after
LQVHUWLQJWKHÀDWSDQHOVHQVRU
Indicates the charge level of the battery pack for
WKHÀDWSDQHOVHQVRULQ\HOORZLVKJUHHQ
Lights in orange when an error occurs.
Mute switch
This switch is used to mute the buzzer that sounds when an exposure is ready,
DÀDWSDQHOVHQVRULVLQVHUWHGRUWKHEDWWHU\SDFNRIDÀDWSDQHOVHQVRULVIXOO\
charged.
Flat panel sensor
LGHQWLÂżFDWLRQODPS
7KLVODPSLVOLWLQWKHVDPHFRORUDVWKHÀDWSDQHOVHQVRULGHQWL¿FDWLRQODPSRQ
WKHÀDWSDQHOVHQVRUFXUUHQWO\LQXVH
READY lamp (Green)
7KLVODPSLVOLWZKHQWKHÀDWSDQHOVHQVRUFXUUHQWO\LQXVHLVUHDG\IRUH[SRVXUH
‡1RWHWKDWWKHÀDWSDQHOVHQVRULQVHUWHGLQWRWKHGRFNLQJVWDQGFDQRQO\EHFKDUJHGRUXVHGIRUFRPPXQLFDWLRQ
It cannot be used for exposures.
• If the battery pack level indicator of the docking stand lights in orange, press the main switch to turn it off and
press the switch again to turn the power back on.
2-6
FDR D-EVO II Operation Manual
897N120339A
Ĺś DR-ID 1200MC
Main switch/
power status LED
Control cabinet (DR-ID 1200MC)
Control cabinet
(DR-ID 1200MC)
System Configuration (Product Overview)
Name
Description
$SHUVRQDOFRPSXWHUXVHGIRUFRQWUROOLQJWKHÀDWSDQHOVHQVRUDQG
performing image processing.
Main switch
Supplies the power to the control cabinet.
Power status LED
Displays ON/OFF of the control cabinet.
'HSHQGLQJRQWKHFRQÂżJXUDWLRQWKHFRQWUROFDELQHW '5,'0& PD\QRWEHLQFOXGHGLQWKHV\VWHP,IQRW
included, the software for the control cabinet can be installed on the image processing unit (DR-ID 300CL).
)RUGHWDLOVSHFL¿FDWLRQRILPDJHSURFHVVLQJXQLWSOHDVHUHIHUWR³'5,'&/2SHUDWLRQ0DQXDO´
Ĺś SE cable
Name
SE cable
Description
$FDEOHWKDWFRQQHFWVWKHÀDWSDQHOVHQVRUDQGWKHSRZHUVXSSO\XQLW
7KLVFDEOHLVXVHGIRUDGGLQJWKHVHFRQGDQGVXEVHTXHQWÀDWSDQHO
VHQVRUVFKDQJLQJRYHUWKHFRQQHFWLRQEHWZHHQWKHÀDWSDQHOVHQVRUVDQG
other usages.
&DEOHOHQJWK$SSUR[P IW $SSUR[P IW
FDR D-EVO II Operation Manual
897N120339A
2-7
Ĺś SE communication cable
Name
Description
SE communication cable
System Configuration (Product Overview)
$FDEOHXVHGIRUFRQQHFWLQJWKHÀDWSDQHOVHQVRUDQGWKHRSWLRQDODFFHVVSRLQW
This cable is used for wired communication if wireless communication is not
available.
,QDGGLWLRQWKLVFDEOHLVXVHGIRUUHJLVWHULQJRUUHFRJQL]LQJWKHÀDWSDQHOVHQVRU
&DEOHOHQJWK$SSUR[P IW
Ĺś %DWWHU\FKDUJHU 2SWLRQDO
Battery charger
Name
Description
Battery charger
&KDUJHVWKHEDWWHU\SDFNIRUWKHÀDWSDQHOVHQVRU7ZRSDFNVFDQEH
charged at the same time.
Charge status indicator LED
Indicates charge status.
Ĺś ,PDJHSURFHVVLQJXQLW
For the unit names and functions of the image processing unit, see the “DR-ID 300CL Operation
Manual”.
2-8
FDR D-EVO II Operation Manual
897N120339A
 ,PDJH3URFHVVLQJ8QLW'LVSOD\
&RQILJXUDWLRQ
When the self-initialization process ends, the Patient Information Input Screen will appear on the image
processing unit display.
For details, see “DR-ID 300CL Operation Manual”.
Ĺś Patient Information Input Screen
Patient information input field
Input patient information.
Tool button
Operates the Patient Information
Database function to input patient
information.
6\VWHP&RQILJXUDWLRQ 3URGXFW2YHUYLHZ
Clears patient information
(except for technologist).
Screen keyboard
Used to input characters in the
patient information input field.
Reserves a study.
Terminates patient information
input, and proceeds to exposure
menu selection.
Displays the “Study List screen”.
Connected devices status
Connected devices status display field. Displays the status of connected devices.
For details, see the next page.
Ĺś Study Screen
Patient information display field
Displays patient information.
Exposure menu list
This list shows exposure
menus selected on the
“Exposure Menu Selection
screen”.
Selected exposure menu
number display field
Exposure unit display field
The Tube, Technique, and
Imaging panels can be uniquely
arranged and displayed.
Technologist display field
Image display field
The read image appears.
Displays the name of loggedin technologist (user).
Shot Ready (exposure ready status indicator)
Exposure (image reading) can be performed when the indicator is lit green.
Exposure (image reading) cannot be performed when the indicator is not lit.
FDR D-EVO II Operation Manual
897N120339A
2-9
Ĺś Connected Devices Status
Details on each icon and its display area are described below.
Other indicator icons display area
Other indicator icons display area
System Configuration (Product Overview)
7KHVWDWXVRIWKHÀDWSDQHOVHQVRUSRZHUVXSSO\XQLWGRFNLQJVWDQGDQGLPDJHSURFHVVLQJXQLW
is shown with an icon. Up to six icons can be displayed. The status of each connected device is
shown in three categories.
Device information displayed in each category is as follows.
Category
Status of exposure unit
Status of the image processing
unit and personal computer
Other (Status of output unit,
hospital LAN, etc.)
Device information
(1) Exposure unit communication indicator
(2) Exposure unit battery indicator
(3) Console event indicator
(4) Console battery indicator
(5) Output status indicator
(6) Hospital wireless communication indicator
The information is displayed in each category as shown below.
Device information of the category
Category
Locations of category information can be customized in the user utility. For details, see “DR-ID
300CL Reference Guide”.
2-10
FDR D-EVO II Operation Manual
897N120339A
(1) Exposure Unit Communication Indicator
7KHIROORZLQJLFRQVGLVSOD\FRPPXQLFDWLRQVWDWXVRIWKHÀDWSDQHOVHQVRUFRUUHVSRQGLQJWRWKH
VHOHFWRUVHOHFWHGLQWKHH[SRVXUHXQLWGLVSOD\¿HOGRIWKH³6WXG\VFUHHQ´
,IWKHÀDWSDQHOVHQVRULVFRQQHFWHGZLWKZLUHGFRPPXQLFDWLRQWKHIROORZLQJLFRQVDUHGLVSOD\HG
&RQQHFWHG
8QNQRZQ
,IWKHÀDWSDQHOVHQVRULVFRQQHFWHGZLUHOHVVO\WKHIROORZLQJLFRQVDUHGLVSOD\HG
&RQQHFWHG'LVSOD\VWKHVLJQDOVWUHQJWKLQIRXUOHYHOV
'LVFRQQHFWHG
6\VWHP&RQILJXUDWLRQ 3URGXFW2YHUYLHZ
8QNQRZQ
CAUTIONS
While
LVGLVSOD\HGUDGLRJUDSK\LVQRWUHFRPPHQGHGVLQFHZLUHOHVVFRPPXQLFDWLRQLVXQVWDEOH
(2) Exposure Unit Battery Indicator
When the exposure unit is connected to the image processing unit, the battery status is indicated
with the following icons.
5HDG\IRUH[SRVXUH EDWWHU\FKDUJHIXOO\FKDUJHG
5HDG\IRUH[SRVXUH H[SRVXUHWLPHDYDLODEOHOHVVWKDQRQHKRXU
5HDG\IRUH[SRVXUH EDWWHU\FKDUJHUHFKDUJHQHHGHG
5HDG\IRUH[SRVXUH FRQQHFWHGWRSRZHUVXSSO\
1RWUHDG\IRUH[SRVXUH
CAUTIONS
:KHQDQH[SRVXUHLVUHDG\WREHPDGH WKH5($'<VWDWXVODPSRQWKHÀDWSDQHOVHQVRULVOLW
JUHHQ WKHSRZHUFRQVXPSWLRQRIWKHÀDWSDQHOVHQVRULQFUHDVHV$OWKRXJKWKHLQGLFDWRULFRQRI
WKHUHPDLQLQJEDWWHU\OHYHOFKDQJHVWRORZDQGWKHYDOXHRIWKHRSHUDEOHWLPHGLVSOD\GHFUHDVHV
temporarily, these are not failures.
(3) Console Event Indicator
The following icons display the status of the image processing unit.
1RUPDO
:DUQLQJOHYHOHYHQWRQJRLQJ
(UURUOHYHOHYHQWRQJRLQJ
FDR D-EVO II Operation Manual
897N120339A
2-11
(4) Console Battery Indicator
The status of the PC battery and of PC connection to the AC adapter are shown by the icons
below.
5HDG\IRUXVH
5HDG\IRUXVH
5HDG\IRUXVH EDWWHU\FKDUJHUHFKDUJHQHHGHG
5HDG\IRUXVH FKDUJLQJRUWKH$&DGDSWHUFRQQHFWHG
1RWUHDG\IRUXVH
(5) Output Status Indicator
The following icons display the output status.
6\VWHP&RQILJXUDWLRQ 3URGXFW2YHUYLHZ
:DLWLQJIRULPDJHRXWSXW
3URFHVVLQJLPDJHRXWSXW
2XWSXWHUURU
(6) Hospital Wireless Communication Indicator
The status of wireless communication between the image processing unit and the hospital LAN is
shown by the icons below.
&RQQHFWHG5DGLRÂżHOGVWUHQJWKLVGLVSOD\HGLQIRXUOHYHOV
6ZLWFKLQJFRQQHFWLRQ
'LVFRQQHFWHG
CAUTIONS
While  LV GLVSOD\HG LPDJH WUDQVIHU WR WKH KRVSLWDO /$1 EHFRPHV XQVWDEOH DOWKRXJK ZLUHOHVV
communication is established.
2-12
FDR D-EVO II Operation Manual
897N120339A
 5RXWLQH2SHUDWLRQ'LDJUDP
7KHV\VWHPFRQÂżJXUDWLRQDQGWKHURXWLQHRSHUDWLRQGLDJUDPIRUWKH)'5'(92II is as follows.
FDR D-EVO2 (DR-ID 1200)
DR-ID 1200PU/DR-ID 1200DU
• X-ray exposure
• Image reading
Image Processing Unit
Image data
• Patient information entry
• Exposure region / study menu selection
DR-ID 1200PU/DR-ID 1200DU
System Configuration (Product Overview)
• Image processing, etc.
Image data
Image data
Imager
• Film output
Image Management Workstation
• DICOM-conformed
open network supported
FDR D-EVO II Operation Manual
897N120339A
2-13
2.5 Wireless Specifications

7HFKQLFDO6SHFLÂżFDWLRQIEEE802.11n (protocol) , 2.4GHz, W52, W53, W56, W58 (frequency)

,QWHQGHGHQYLURQPHQW5RRPVL]HRIP[P[P IW[IW[IW  KHLJKW RU
less (general X-ray room)
(The electric shield does not exist excluding the installation stand or
bed.)

,QVWDOODWLRQ'RQRWSODFHGHYLFHVJHQHUDWLQJHOHFWURPDJQHWLFZDYH &705,GLDWKHUP\
RFID etc.) near this equipment.
We recommend not to use any other wireless devices such as cellular/smart
phones, portable phones, microwave ovens, WAPs, etc. within 2m (6.6 ft) of
the wireless FDR D-EVO II system.
When other wireless devices are used within 2m (6.6 ft), wireless data
communication may be delayed.
(Data will not be lost; if a timeout occurs a retry can be performed after the
cause of interference has been removed)
Do not cover the Flat Panel Sensor (DR-ID 1201SE/DR-ID 1202SE/DR-ID
1211SE/DR-ID 1212SE) with a shield such as a metallic plate as this will
interfere with a wireless communication.

,QIRUPDWLRQEHLQJWUDQVPLWWHG6\VWHP&RQWURO6LJQDO ,PJBUHTB&0'HWF
Image Data of the Flat Panel Sensor
1RWH3DWLHQW,QIRUPDWLRQLVQRWWUDQVPLWWHGE\ZLUHOHVV
interface of Access point

:LUHOHVVUDQJHPD[P IW IURPWKH$FFHVVSRLQWDVWHVWHG$FWXDOUDQJHPD\YDU\

'DWDWUDQVIHUUDWH0ESV '5,'EHWZHHQWKH)ODW3DQHO6HQVRUDQG&RQVROH3&
(This value is FUJIFILM measuring result of wireless module, and
actual data rate may vary.)

7UDQVIHU3RZHUG%PRUOHVV

0RGXODWLRQ2)'0 3URYLGHGE\,(((Q
System Configuration (Product Overview)
:LUHOHVV'DWD6HFXULW\:LUHOHVV)'5'(92II system (DR-ID 1201SE/DR-ID 1202SE/
DR-ID 1211SE/DR-ID 1212SE) will be utilizing the IEEE 802.11n.
The Wireless Access Point (WAP) has a feature that limits the
maximum number of the Flat Panel Sensor per access point to
ensure data integrity. Further the WAP has MAC Address Filtering
(unique IP address) and Wireless LAN Segmentation to ensure
handshaking with only the registered wireless FDR D-EVO II Flat
Panel Sensors (DR-ID 1201SE/DR-ID 1202SE/DR-ID 1211SE/
DR-ID 1212SE).
,QDGGLWLRQWRWKH0$&DGGUHVVÂżOWHULQJWKHZLUHOHVV
communication between DR-ID 1201SE/DR-ID 1202SE/DR-ID
1211SE/DR-ID 1212SE (Flat Panel Sensor) and access point is
secured by WPA2-PSK encryption with AES (Advanced Encryption
Standard). Data security feature will be enabled during installation
E\D)8-,),/0ÂżHOGVHUYLFHHQJLQHHU1RSDWLHQWLQIRUPDWLRQ
is transmitted between DR-ID 1201SE/DR-ID 1202SE/DR-ID
1211SE/DR-ID 1212SE (Flat Panel Sensor) and access point.,
between access point and the console.
 +DQGVKDNLQJ3DLULQJ7KH:LUHOHVV$FFHVV3RLQWDQG'5,'6('5,'6('5
ID 1211SE/DR-ID 1212SE (Flat Panel Sensor) will be paired during
LQVWDOODWLRQE\D)8-,),/0ÂżHOGVHUYLFHHQJLQHHUWRHQVXUHRQHWRRQH
ZLUHOHVVFRQQHFWLRQ)8-,),/0ÂżHOGVHUYLFHHQJLQHHUZLOOPHDVXUH
the wireless transmission condition in the primary area, so the FDR
D-EVO II system can be used stable.
 )UHTXHQF\7ROHUDQFH“SSP

2-14
FDR D-EVO II Operation Manual
897N120339A
Quality of Service (QoS)
Item
Form of electric
wave
Center frequency
DR-ID 1201SE/DR-ID 1202SE/
Unit
DR-ID 1211SE/DR-ID 1212SE
Standard
Remarks
Spectrum diffusion
HT20
5180 - 5825
2412 - 2472
MHz 36ch,40ch,44ch,48ch
W52
HT40
5190 - 5795
2422 - 2462
MHz
Channel interval
IEEE802.11n
20(HT20) / 40(HT40)
Transmission rate
IEEE802.11n
HT20䠖MCS0-15
38ch,46ch
W52
HT40䠖MCS0-15
Output power
Max
Frequency
Tolerance
OFDM
Power
17
dBm
- 20 ~ +20
ppm
Reception
MCS0=-89
dBm
sensitivity
MCS1=-86
dBm
PER :
MCS2=-83
dBm
MCS0=-86
dBm
MCS1=-83
dBm
MCS2=-80
dBm
MCS0=-88
dBm
MCS1=-85
dBm
MCS2=-82
dBm
MCS0=-85
dBm
MCS1=-82
dBm
MCS2=-79
dBm
Packet Error
IEEE 802.11n
(5GHz)
Rate <10%
IEEE 802.11n
(2.4GHz)
System Configuration (Product Overview)
Modulation
MAX
HT20
HT40
HT20
HT40
)RUGHWDLOVRQWKHZLUHOHVVVSHFLÂżFDWLRQRIWKHLPDJHSURFHVVLQJXQLWVHHWKHÂł&RQVROH$GYDQFH '5,'&/ 
Operation Manual”.
FDR D-EVO II Operation Manual
897N120339A
2-15
2
System Configuration (Product Overview)
2-16
FDR D-EVO II Operation Manual
897N120339A
Chapter 3
Basic Operation
 3UHSDULQJWKH)ODW3DQHO6HQVRU
7KLVVHFWLRQGHVFULEHVKRZWRSUHSDUHWKHÀDWSDQHOVHQVRU
3.1.1 Type of Flat Panel Sensor
DR-ID 1201SE, DR-ID 1202SE, DR-ID 1211SE, DR-ID 1212SE
7KHEDWWHU\SDFN RSWLRQDO LVUHTXLUHGZKHQWKHÀDWSDQHOVHQVRULVXVHGLQZLUHOHVVFRPPXQLFDWLRQ
mode.
3.1.2 Number of the Connectable Flat Panel Sensors
Basic Operation
7RHQDEOHWKHÀDWSDQHOVHQVRULWV,'QHHGVWREHUHJLVWHUHGLQDGYDQFHE\RXURI¿FLDOGHDOHURU
FUJIFILM Representative.
8SWRDKXQGUHGÀDWSDQHOVHQVRUVFDQEHUHJLVWHUHG
8SWR¿YHÀDWSDQHOVHQVRUVFDQEHFRQQHFWHG
:KHQWKH'5,'38LVXVHGXSWRWZRÀDWSDQHOVHQVRUVFDQEHFRQQHFWHGWRRQHSRZHU
supply unit in wired communication mode. Up to two power supply unit can be used.
:KHQWKH'5,''8LVXVHGRQO\RQHÀDWSDQHOVHQVRUVFDQEHFRQQHFWHGWRRQHGRFNLQJ
stand in wired communication mode. Up to three docking stand can be used.
'HSHQGLQJRQWKHFRQÂżJXUDWLRQWKHFRQWUROFDELQHW '5,'0& PD\QRWEHLQFOXGHGLQWKHV\VWHP,IQRW
included, the software for the control cabinet can be installed on the image processing unit (DR-ID 300CL).
)RUGHWDLOVSHFL¿FDWLRQRILPDJHSURFHVVLQJXQLWSOHDVHUHIHUWR³'5,'&/2SHUDWLRQ0DQXDO´
 &RQQHFWLQJ'LVFRQQHFWLQJWKH)ODW3DQHO6HQVRU
Connector
Disconnect the connector.
Press the latches on both sides of the connector.
Connect the connector.
Press the connector into the insertion section.
Make sure that the latches on both sides are
properly engaged when connecting the connector.
If the connector is inserted incompletely, the power
may turn off.
 KHQPXOWLSOHÀDWSDQHOVHQVRUVDUHXVHGPDNHVXUHWKDWWKH5($'<ODPSDPRQJWKHVWDWXVODPSVRIWKHÀDW
panel sensor to be used for an exposure is lit.
FDR D-EVO II Operation Manual
897N120339A
3-1
&RQQHFW'LVFRQQHFWWKHFRQQHFWRUVWUDLJKWWRWKHÀDWSDQHOVHQVRU,IFRQQHFWHGGLVFRQQHFWHGDWDQDQJOHWKH
connector may be damaged.
 ,QVHUWLQJ5HPRYLQJWKH)ODW3DQHO6HQVRULQWRIURPWKH
5DGLRJUDSKLF([DPLQDWLRQ6WDQG
 ROORZWKHSURFHGXUHEHORZWRLQVHUWUHPRYHWKHÀDWSDQHOVHQVRULQWRIURPWKHUDGLRJUDSKLF
examination stand.
Basic Operation
For details, see the Operation Manual for the radiographic examination stand.
CAUTIONS
 RUWKHSRVLWLRQLQJDWWKHWLPHRILQVHUWLQJUHPRYLQJWKHÀDWSDQHOVHQVRUVHHWKH2SHUDWLRQ
0DQXDOIRUWKHUDGLRJUDSKLFH[DPLQDWLRQVWDQG
CAUTIONS
0DNHVXUHWKDWWKHÀDWSDQHOVHQVRULVLQVWDOOHGLQWKHUDGLRJUDSKLFH[DPLQDWLRQVWDQGVHFXUHO\
CAUTIONS
 HFDUHIXOQRWWRKDYH\RXU¿QJHUVFDXJKWZKHQLQVHUWLQJUHPRYLQJWKHÀDWSDQHOVHQVRULQWR
IURPWKHUDGLRJUDSKLFH[DPLQDWLRQVWDQG
CAUTIONS
:KHQSXOOLQJRXWSXVKLQJLQWKHWUD\RIWKHUDGLRJUDSKLFH[DPLQDWLRQVWDQGDIWHUVHWWLQJWKHÀDW
SDQHOVHQVRURQLWEHFDUHIXOQRWWRGURSWKHÀDWSDQHOVHQVRURUGDPDJHWKHWUD\
CAUTIONS
%HIRUHLQVHUWLQJUHPRYLQJWKHÀDWSDQHOVHQVRULQWRIURPWKHUDGLRJUDSKLFH[DPLQDWLRQVWDQG
SXOORXWWKHWUD\FRPSOHWHO\2WKHUZLVHWKHÀDWSDQHOVHQVRUPD\EHGDPDJHG
)RUWKHHIIHFWLYHDUHDRIWKHÀDWSDQHOVHQVRUVHHSDJH$
3-2
FDR D-EVO II Operation Manual
897N120339A
>@8SULJKWW\SH
3
6HWWKHÀDWSDQHOVHQVRUWRWKHXSSHUSDUWRI
the tray.
4
3XVKWKHWUD\EDFNLQWRSODFHDIWHUVHWWLQJ
WKHÀDWSDQHOVHQVRU
CAUTIONS
:KHQLQVHUWLQJWKHÀDWSDQHOVHQVRULQWR
WKHUDGLRJUDSKLFH[DPLQDWLRQVWDQGGLUHFW
WKHH[SRVXUHSODQHWRZDUGWKH;UD\WXEH
Pull out the tray.
Tray
,QVHUWWKHÀDWSDQHOVHQVRULQWRWKHFDVVHWWH
UHFHLYHZLWKWKHJUHHQPDUNRIWKHÀDWSDQHO
sensor up, and then move it downwards.
Basic Operation
Green mark
5
5HPRYHWKHÀDWSDQHOVHQVRUDIWHUXVH
Pull out the tray, push the cassette receive
GRZQZDUGVDQGWKHQUHPRYHWKHÀDWSDQHOVHQVRU
Push the tray back into place.
Cassette receive
FDR D-EVO II Operation Manual
897N120339A
3-3
[2] Bed type
Center mark
CAUTIONS
:KHQLQVHUWLQJWKHÀDWSDQHOVHQVRU
WRWKHUDGLRJUDSKLFH[DPLQDWLRQVWDQG
direct the exposure plane upwards.
1
3XOORXWWKHWUD\E\XVLQJWKHKDQGOH
3
3XVKWKHWUD\EDFNLQWRSODFHE\XVLQJWKH
KDQGOHDIWHUVHWWLQJWKHÀDWSDQHOVHQVRU
4
5HPRYHWKHÀDWSDQHOVHQVRUDIWHUXVH
Tray
Basic Operation
2
3XOOWKHFDVVHWWHVWRSSHUDQGVHWWKHÀDW
SDQHOVHQVRUVRWKDWLWVFHQWHUPDUNLV
DOLJQHGZLWKWKHFHQWHURIWKHVWRSSHU
Hold the handle and pull out the tray. Remove the
ÀDWSDQHOVHQVRUZKLOHSXOOLQJWKHFDVVHWWHVWRSSHU
and then push the tray back into place.
Cassette
stopper
 &KDQJLQJWKH'LUHFWLRQRIWKH)ODW3DQHO6HQVRU
Connector
7KHGLUHFWLRQRIWKHFRQQHFWRURIWKHÀDWSDQHOVHQVRUFDQEHFKDQJHGGHSHQGLQJRQKRZLWLV
inserted into the radiographic examination stand.
7RFKDQJHWKHGLUHFWLRQFRQWDFWRXURIÂżFLDOGHDOHURU)8-,),/05HSUHVHQWDWLYH
When shipped
3-4
FDR D-EVO II Operation Manual
897N120339A
After changing the direction
 &KDUJLQJWKH%DWWHU\3DFNIRUWKH)ODW3DQHO6HQVRU
Charge the battery pack (optional) using the battery charger (optional).
CAUTIONS
'RQRWFKDUJHWKHEDWWHU\SDFNRWKHUWKDQWKRVHGHVLJQDWHGE\)8-,),/0&RUSRUDWLRQ,IWKH
EDWWHU\SDFNLVFKDUJHGXQGHUWKHFKDUJLQJFRQGLWLRQV YROWDJHFXUUHQWDQGFKDUJLQJPHWKRG 
GLIIHUHQWIURPWKRVHVSHFLÂżHGE\)8-,),/0&RUSRUDWLRQWKHEDWWHU\SDFNPD\HPLWVPRNH
LJQLWHH[SORGHRUOHDNÀXLG
CAUTIONS
:KHQVHWWLQJWKHEDWWHU\SDFNLQWRWKHEDWWHU\FKDUJHUPDNHVXUHWKDWWKHRULHQWDWLRQRIWKH
EDWWHU\SDFNLVFRUUHFWDVVKRZQLQWKHÂżJXUHLQ6WHS 1 ,IWKHEDWWHU\SDFNLVIRUFLEO\VHWLQ
WKHZURQJRULHQWDWLRQERWKWKHEDWWHU\SDFNDQGWKHEDWWHU\FKDUJHUPD\EHGDPDJHGDQGHPLW
VPRNHLJQLWHOHDNÀXLGRUFDXVHHOHFWULFVKRFN
Basic Operation
:KHQWKHEDWWHU\SDFNLQVWDOOHGLQWKHÀDWSDQHOVHQVRULVIXOO\FKDUJHGLWLVSRVVLEOHWRSHUIRUPH[SRVXUHVIRUD
maximum of approximately 500 images. However, the number varies depending on the usage conditions.
7KHFDSDFLW\RIWKHEDWWHU\SDFNLVGLVSOD\HGRQWKHEDWWHU\SDFNOHYHOLQGLFDWRURIWKHÀDWSDQHOVHQVRUDQGRQWKH
screen of the image processing unit.
:KHQWKHUHPDLQLQJFDSDFLW\RIWKHEDWWHU\SDFNRIWKHÀDWSDQHOVHQVRUEHFRPHVOHVVWKDQDSSUR[PLQXWHV
a pop-up window appears on the image processing unit display, and exposure cannot be performed. If this
happens, replace or charge the battery pack.
:KHQWKHUHPDLQLQJFDSDFLW\RIWKHEDWWHU\SDFNLQVWDOOHGLQWKHÀDWSDQHOVHQVRUEHFRPHVORZWKHEDWWHU\SDFN
OHYHOLQGLFDWRULVOLWLQRUDQJHDQGH[SRVXUHVFDQQRWEHSHUIRUPHG,IWKLVKDSSHQVFRQQHFWWKH6(FDEOHWRWKHÀDW
panel sensor to charge the battery pack.
1
6HWWKHEDWWHU\SDFNLQWKHEDWWHU\FKDUJHU
When the battery pack is set, a buzzer sound is
generated and the charge status indicator LED
lights.
Two battery packs can be charged at the same time.
2
:KHQEDWWHU\FKDUJHLVFRPSOHWHGUHPRYH
WKHEDWWHU\SDFN
When battery charge is completed, the charge status
indicator LED changes from blinking to lighting.
FDR D-EVO II Operation Manual
897N120339A
3-5
3.1.7 &KDUJLQJWKH,PDJH3URFHVVLQJ8QLW
For details, refer to the manual of the personal computer.
 ,QVWDOOLQJ5HPRYLQJWKH%DWWHU\3DFNIRUWKH)ODW3DQHO
Sensor
)ROORZWKHSURFHGXUHEHORZWRLQVWDOOUHPRYHWKHEDWWHU\SDFNIRUWKHÀDWSDQHOVHQVRU
:KHQLQVWDOOLQJUHPRYLQJWKHEDWWHU\SDFNSODFHWKHÀDWSDQHOVHQVRURQDÀDWSODFH
Do not remove the battery pack until a processed image appears in the window of the image processing unit after
the exposure.
Remove the battery cover.
Basic Operation
3ODFHWKHÀDWSDQHOVHQVRUZLWKWKHEDFNVLGHIDFLQJ
XSZDUGSUHVVWKH³Ɣ´SRUWLRQRIWKHORFNOHYHUDQG
then slide it in the direction of the arrow to remove
the battery cover.
Guide marks
Battery pack
• To remove the battery pack, perform the same
procedure as Step 1 (removing the battery cover).
Battery pack
2
,QVWDOOWKHEDWWHU\SDFN
Slide the battery pack along the dent of the battery
VHFWLRQRIWKHÀDWSDQHOVHQVRUWRZDUGWKHFRQQHFWRU
terminal. Align the guide mark of the battery pack
ZLWKWKDWRIWKHÀDWSDQHOVHQVRUDQGSXVKWKH
battery pack in to install it.
Make sure that battery pack is securely installed.
Pushing the battery pack in with the guide marks
misaligned may damage the connector terminal.
When attaching the battery pack, make sure that
the waterproof packing attached to the connector
WHUPLQDORIWKHÀDWSDQHOVHQVRULVDOLJQHGSURSHUO\
:KHQWKHEDWWHU\SDFNLVLQVWDOOHGLQWKHÀDWSDQHO
sensor, the power is automatically turned on.
3-6
FDR D-EVO II Operation Manual
897N120339A
• To install the battery cover, perform the same
procedure as Step 2 (installing the battery pack).

/DPS,QGLFDWLRQVRQWKH)ODW3DQHO6HQVRU
7KLVVHFWLRQH[SODLQVWKHLQGLFDWLRQVRIWKHÀDWSDQHOVHQVRULGHQWL¿FDWLRQODPSDQGWKHEDWWHU\SDFN
level indicator. For other lamp indications, see “2.2.1 DR-ID 1200”.
Ĺś)ODWSDQHOVHQVRULGHQWLÂżFDWLRQODPS
7KHÀDWSDQHOVHQVRULVDFWLYH
%OLQNLQJLQZKLWH
While in sleep/extra sleep mode
%OLQNLQJLQLGHQWLÂżFDWLRQFRORU
While detecting an impact
%OLQNLQJLQUHG
Ĺś %DWWHU\SDFNOHYHOLQGLFDWRU
LED0
LED3 LED2 LED1
(When the battery pack is being charged)
/('/LWLQJUHHQ
$YDLODEOHWLPHPLQXWHVRUPRUH
/('%OLQNLQJLQJUHHQ/('/LWLQJUHHQ
$YDLODEOHWLPHPLQXWHVRUPRUHEXWOHVVWKDQPLQXWHV
/('%OLQNLQJLQJUHHQ/('/LWLQJUHHQ
$YDLODEOHWLPH/HVVWKDQPLQXWHV
/('%OLQNLQJLQJUHHQ
Basic Operation
Fully charged
(When the battery pack is not charged)
$YDLODEOHWLPHPLQXWHVRUPRUH
/('/LWLQJUHHQ
$YDLODEOHWLPHPLQXWHVRUPRUHEXWOHVVWKDQPLQXWHV
/('/LWLQJUHHQ
$YDLODEOHWLPH/HVVWKDQPLQXWHV
/('/LWLQJUHHQ
$YDLODEOHWLPHPLQXWHVRUOHVV
/('/LWLQRUDQJH
FDR D-EVO II Operation Manual
897N120339A
3-7
 $WWDFKLQJWKH)ODW3DQHO6HQVRUWRWKH'RFNLQJ6WDQG
CAUTIONS
Ɣ +
 DQGOHWKHGRFNLQJVWDQGFDUHIXOO\'RQRWKLWRUGURSWKHGRFNLQJVWDQGRUVXEMHFWLWWR
VHYHUHVKRFNWRDYRLGSRVVLEOHGDPDJH
Ɣ ,IDQ\GDPDJHVXFKDVFUDFNLQJFKLSSLQJRUSHHOLQJLVIRXQGRQWKHGRFNLQJVWDQGXVHLW
after repair. Otherwise, personal injury may result. Consult a FUJIFILM dealer for repair.
Ɣ ,IH[FHVVLYHIRUFHLVDSSOLHGWRWKHGRFNLQJVWDQGLWPD\EHGDPDJHG,QDGGLWLRQGRQRW
DSSO\H[FHVVLYHIRUFHWRWKHÀDWSDQHOVHQVRULQVHUWHGLQWKHGRFNLQJVWDQG
Ɣ :
 KHQPRYLQJWKHGRFNLQJVWDQGWKDWKDVDOUHDG\EHHQLQVWDOOHGFRQVXOWRXURIÂżFLDOGHDOHU
or local representative.
Ɣ '
 RQRWSXOOWKHFDEOHIRUFLEO\2WKHUZLVHWKHFDEOHPD\EHEURNHQRUWKHGRFNLQJVWDQGPD\
EHGDPDJHG
1
'LVFRQQHFWWKHFRQQHFWRUIURPWKHÀDW
panel sensor and then attach the adapter for
WKHGRFNLQJVWDQG
HINT
When removing the adapter for the docking stand
IURPWKHÀDWSDQHOVHQVRUVOLGHWKHORFNNH\RQWKH
adapter for the docking stand toward the right side.
Basic Operation
Lock Key
2
,QVHUWWKHÀDWSDQHOVHQVRU
Check the position of the adapter for the docking
VWDQGDOLJQWKHÀDWSDQHOVHQVRUZLWKWKHGRFNLQJ
VWDQGDQGVORZO\LQVHUWWKHÀDWSDQHOVHQVRUVWUDLJKW
into the docking stand until it stops along the right
and left guides of the docking stand.
Adapter for the
docking stand
3-8
FDR D-EVO II Operation Manual
897N120339A
3.2 6WDUWLQJ8SDQG6KXWWLQJ'RZQWKH6\VWHP
This section explains how to start up and shut down the system. Operations are required on the power
VXSSO\XQLWGRFNLQJVWDQGÀDWSDQHOVHQVRUDQGLPDJHSURFHVVLQJXQLW
The image processing unit in this section is only an example. For details on the image processing unit being used,
see the Operation Manual provided with the personal computer.
 6WDUWLQJ8SWKH6\VWHP
(When the DR-ID 1200PU is used)
Make sure that the power cable is connected to the image processing unit.
:KHQWKHÀDWSDQHOVHQVRULVXVHGLQZLUHOHVVFRPPXQLFDWLRQPRGHLQVWDOOWKHIXOO\FKDUJHG
EDWWHU\SDFNWRWKHÀDWSDQHOVHQVRU
:KHQLWLVXVHGLQZLUHGFRPPXQLFDWLRQPRGHFRQQHFWWKHÀDWSDQHOVHQVRUDQGWKHSRZHU
VXSSO\XQLWXVLQJWKH6(FDEOH
Press the ON side of the main switch of the power supply unit.
Basic Operation
1
Make sure that the power status LED is lit in blue.
3
:KHQWKHRSWLRQDODFFHVVSRLQWLVXVHGFRQQHFWWKHDFFHVVSRLQWWRWKHLPDJHSURFHVVLQJXQLW
CAUTIONS
8VHWKHRSWLRQDODFFHVVSRLQWE\FRQQHFWLQJLWWRWKHSUHVHWLPDJHSURFHVVLQJXQLWDQGWRWKH86%
FRQQHFWRU'RQRWXVHWKHRSWLRQDODFFHVVSRLQWE\FRQQHFWLQJLWWRRWKHULPDJHSURFHVVLQJXQLWDQG
or USB connector.
Press the ON side of the main switch of the power supply unit.
The initialization process starts.
• All cables should be connected properly.
• No media should be inserted into the disk drive of image processing unit.
If the control cabinet is included in the system, the control cabinet starts up automatically.
CAUTIONS
,IWKHSRZHUVWDWXV/('RIWKHFRQWUROFDELQHWGRHVQRWFRPHRQDIWHUWXUQLQJRQWKHLPDJH
SURFHVVLQJXQLWWXUQRQWKHFRQWUROFDELQHW
FDR D-EVO II Operation Manual
897N120339A
3-9
5
7KH3DWLHQW,QIRUPDWLRQ,QSXW6FUHHQEHORZDSSHDUVIROORZLQJWKHRSHQLQJVFUHHQRQWKHLPDJH
SURFHVVLQJXQLWPRQLWRU
Patient Information Input Screen
CAUTIONS
Basic Operation
An error occurs if the system is started up immediately after shutdown.
7RUHVWDUWWKHV\VWHPLQFOXGLQJWKHFRQWUROFDELQHWPDNHVXUHWKDWWKHSRZHUVWDWXV/('RIWKH
FRQWUROFDELQHWLVRIIDQGWKHQSUHVVWKHSRZHUVZLWFKIRUWKHLPDJHSURFHVVLQJXQLW
CAUTIONS
Ɣ '
 RQRWFRQQHFWGLVFRQQHFWWKHÀDWSDQHOVHQVRUWRIURPWKHSRZHUVXSSO\XQLWRUWRIURPWKH
GRFNLQJVWDQGZKLOHWKHPHVVDJH³&DOLEUDWLQJ´LVGLVSOD\HGLQWKHFRQQHFWHGGHYLFHVVWDWXV
DIWHUWKHV\VWHPVWDUWXS2WKHUZLVHWKHV\VWHPGRHVQRWVWDUWXSQRUPDOO\UHVXOWLQJLQDQHUURU
Ɣ 
may be displayed in the connected devices status while information on radio wave
VWUHQJWKLVEHLQJDFTXLUHGIURPWKHÀDWSDQHOVHQVRU
(When the DR-ID 1200DU is used)
Make sure that the power cable is connected to the image processing unit.
1
7XUQRQWKHPDLQVZLWFKRQWKHGRFNLQJVWDQG
Make sure that the POWER lamp among the status lamps is lit in blue.
2
,QVWDOOWKHIXOO\FKDUJHGEDWWHU\SDFNWRWKHÀDWSDQHOVHQVRU
3
:KHQWKHRSWLRQDODFFHVVSRLQWLVXVHGFRQQHFWWKHDFFHVVSRLQWWRWKHLPDJHSURFHVVLQJXQLW
CAUTIONS
8VHWKHRSWLRQDODFFHVVSRLQWE\FRQQHFWLQJLWWRWKHSUHVHWLPDJHSURFHVVLQJXQLWDQGWRWKH86%
FRQQHFWRU'RQRWXVHWKHRSWLRQDODFFHVVSRLQWE\FRQQHFWLQJLWWRRWKHULPDJHSURFHVVLQJXQLWDQG
or USB connector.
4
3-10
7XUQRQWKHLPDJHSURFHVVLQJXQLW
FDR D-EVO II Operation Manual
897N120339A
5
7KH3DWLHQW,QIRUPDWLRQ,QSXW6FUHHQDSSHDUVRQWKHLPDJHSURFHVVLQJXQLWPRQLWRUDVVKRZQLQ
Step 5 RQ3DJH
CAUTIONS
Ɣ 'RQRWFRQQHFWGLVFRQQHFWWKHÀDWSDQHOVHQVRUWRIURPWKHSRZHUVXSSO\XQLWRUWRIURPWKH
GRFNLQJVWDQGZKLOHWKHPHVVDJH³&DOLEUDWLQJ´LVGLVSOD\HGLQWKHFRQQHFWHGGHYLFHVVWDWXV
DIWHUWKHV\VWHPVWDUWXS2WKHUZLVHWKHV\VWHPGRHVQRWVWDUWXSQRUPDOO\UHVXOWLQJLQDQHUURU
Ɣ 
may be displayed in the connected devices status while information on radio wave
VWUHQJWKLVEHLQJDFTXLUHGIURPWKHÀDWSDQHOVHQVRU
 6KXWWLQJ'RZQWKH6\VWHP
(When the DR-ID 1200PU is used)
1
&RQÂżUPWKDWWKHHTXLSPHQWLVQRWUXQQLQJ7RXFKWKH EXWWRQDWWKHXSSHUULJKWRIWKHLPDJH
SURFHVVLQJXQLWGLVSOD\DQGWKHQWKH
button from the displayed menu. Touch the
EXWWRQLQWKHGLVSOD\HGFRQÂżUPDWLRQZLQGRZ
7KHLPDJHSURFHVVLQJXQLWZLOOVKXWGRZQLQDIHZPLQXWHV,IWKHFRQWUROFDELQHWLVLQFOXGHGLQWKH
system, the control cabinet will also turn off automatically.
Basic Operation
(1)
(2)
(3)
Turn off the display as necessary.
3
0DNHVXUHWKDWFDOLEUDWLRQRIWKHÀDWSDQHOVHQVRULVFRPSOHWHG
:KHQFRPSOHWHGWKH5($'<ODPSRIWKHÀDWSDQHOVHQVRUWXUQVRII
:KHQWKHRSWLRQDODFFHVVSRLQWLVXVHGUHPRYHWKHDFFHVVSRLQWIURPWKHLPDJHSURFHVVLQJXQLW
FDR D-EVO II Operation Manual
897N120339A
3-11
5
Press the OFF side of the main switch of the power supply unit.
Make sure that the power status LED is off.
6
5HPRYHWKHEDWWHU\SDFNIURPWKHÀDWSDQHOVHQVRU6HWWKHVHEDWWHU\SDFNVLQWKHEDWWHU\
FKDUJHU
Battery pack
CAUTIONS
Basic Operation
If the control cabinet is included in the system, do not turn off the control cabinet with the main
switch. Shutdown operation may not be performed normally.
CAUTIONS
:KHQWKHV\VWHPLVVKXWGRZQLPDJHTXDOLW\DGMXVWPHQWLVSHUIRUPHGIRUREWDLQLQJRSWLPDO
GLDJQRVWLFLPDJHV
'RQRWGLVFRQQHFWWKH6(FDEOHRU6(FRPPXQLFDWLRQFDEOHXQWLOV\VWHPVKXWGRZQZKHQWKHÀDW
panel sensor is used in wired communication mode.
5HPRYHWKHEDWWHU\SDFNDIWHUFRQ¿UPLQJV\VWHPVKXWGRZQZKHQWKHÀDWSDQHOVHQVRULVXVHG
in wireless communication mode.
(When the DR-ID 1200DU is used)
Perform Steps 1 1 and 2 RQ3DJH
2
:KHQWKHRSWLRQDODFFHVVSRLQWLVXVHGUHPRYHWKHDFFHVVSRLQWIURPWKHLPDJHSURFHVVLQJ
unit.
3
0DNHVXUHWKDWFDOLEUDWLRQRIWKHÀDWSDQHOVHQVRULVFRPSOHWHG
:KHQFRPSOHWHGWKH5($'<ODPSRIWKHÀDWSDQHOVHQVRUWXUQVRII
4
7XUQRIIWKHPDLQVZLWFKRQWKHGRFNLQJVWDQG
Make sure that the POWER lamp among the status lamps is off.
5
3-12
5HPRYHWKHEDWWHU\SDFNIURPWKHÀDWSDQHOVHQVRU6HWWKHVHEDWWHU\SDFNVLQWKHEDWWHU\
FKDUJHU
FDR D-EVO II Operation Manual
897N120339A
3.3 Routine Operations
FDR D-EVO II routine operations can be broadly divided into the following three steps.
Step 1
Entering the Patient Information
(See page 3-14.)
Step 2
Selecting the Anatomical Region and Exposure/Study Menu
(See page 3-15.)
Step 3
X-ray Exposure
(See page 3-17.)
HINT
Basic Operation
Operations that are actually performed on the FDR D-EVO II are only those described in “ Step 3 X-ray Exposure”.
Other operations are performed on the image processing unit.
For details, see “DR-ID 300CL Operation Manual”.
FDR D-EVO II Operation Manual
897N120339A
3-13
Step 1
1
(QWHULQJWKH3DWLHQW,QIRUPDWLRQ
7KH3DWLHQW,QIRUPDWLRQ,QSXW6FUHHQEHORZLVGLVSOD\HGRQWKHLPDJHSURFHVVLQJXQLWGLVSOD\
immediately after startup.
Enter patient information items appropriately, and then touch the
button.
Not all the items of patient information need to be input.
Input any one of the items in order to proceed to the next operation.
When the optional card reader is provided, patient information can be input by reading from a magnetic card.
Observe the following when the message “Calibrating...” is displayed in the connected devices status.
‡'RQRWVXEMHFWWKHÀDWSDQHOVHQVRUWRVKRFN
• Do not deliver radiation.
‡'RQRWFRQQHFWGLVFRQQHFWWKHÀDWSDQHOVHQVRUWRIURPWKHSRZHUVXSSO\XQLWRUWRIURPWKHGRFNLQJVWDQG
Basic Operation
Patient information input field
Input patient information.
Tool button
Operates the Patient Information
Database function to input patient
information.
Clears patient information
(except for technologist).
Screen keyboard
Used to input characters in the
patient information input field.
Reserves a study.
Terminates patient information
input, and proceeds to exposure
menu selection.
Displays the “Study List screen”.
Connected devices status
Connected devices status display field.
Displays the status of connected devices.
Patient information includes the following items.
Patient’s Name / Sex / Birth Date / Outpatient/Inpatient / Patient ID / Accession No. / Requesting Department / Contrast Allergies /
Patient comments / Study comments
HINT
You can change patient information input items and their display order in the User Utility settings.
3-14
FDR D-EVO II Operation Manual
897N120339A
Step 2
6HOHFWLQJWKH$QDWRPLFDO5HJLRQDQG([SRVXUH6WXG\
Menu
The Exposure Menu Selection Screen is displayed.
6HOHFWDQDQDWRPLFDOUHJLRQIURPWKHGLVSOD\JURXSOLVWDQGWKHQVHOHFWDQH[SRVXUHPHQXIURP
WKHH[SRVXUHPHQXOLVWUHJLVWHUHGWRWKHGLVSOD\JURXSRQWKHORZHUVLGH 0RUHWKDQRQHPHQX
can be selected.)
7KHVHOHFWHGH[SRVXUHPHQX V LVGLVSOD\HGLQWKHVHOHFWHGH[SRVXUHPHQXOLVWRQWKHULJKWVLGH
of the screen.
Display group list
Selected exposure menu list
Basic Operation
Exposure menu list registered to the display group
Touch
DIWHUVHOHFWLQJH[SRVXUHPHQX V 
(1)
(2)
FDR D-EVO II Operation Manual
897N120339A
3-15
3
The Study Screen is then displayed.
Basic Operation
:KHQUHJLVWHULQJDQH[SRVXUHPHQX V PRYHWKHÀDWSDQHOVHQVRUDQGLPDJHSURFHVVLQJXQLWRUDFFHVVSRLQWFORVH
to each other, so that they are within the range of wireless communication.
If the units are out of the range of wireless communication, the message may appear when an exposure menu(s)
LVUHJLVWHUHG,QWKLVFDVHPRYHWKHÀDWSDQHOVHQVRUDQGLPDJHSURFHVVLQJXQLWRUDFFHVVSRLQWFORVHWRHDFK
other, so that they are within the range of wireless communication, and then follow the displayed message.
For details, see “4.1 When a Message Appears on the Image Processing Unit”.
3-16
FDR D-EVO II Operation Manual
897N120339A
Step 3
;UD\([SRVXUH
When settings on the image processing unit have been completed, you can perform an exposure.
CAUTIONS
Ɣ 0DNHVXUHWRLGHQWLI\DSDWLHQWDJDLQVWWKHQDPHRUELUWKGDWHDQGWKHQKDYHKLP KHU WDNHD
SURSHUSRVLWLRQLQJIRUH[SRVXUH
Ɣ 0DNHVXUHWRFRQ¿UPWKHH[SRVXUHPHQXWREHXVHGDQGWKHQKDYHDSDWLHQWWDNHDSURSHU
SRVLWLRQLQJIRUH[SRVXUH
Ɣ :KHQPXOWLSOHSDQHOVDUHXVHGPDNHVXUHWKDWWKH5($'<ODPSDPRQJWKHVWDWXVODPSV
RIWKHÀDWSDQHOVHQVRULVOLWLQRUGHUWRFRQ¿UPWKDWLWLVWKHFRUUHFWRQHIRUWKHVHOHFWHG
WHFKQLTXH
Ɣ $IWHUVWDUWLQJH[SRVLQJRSHUDWLRQGRQRWGLVFRQQHFWRUFRQQHFWWKHFRQQHFWRU,IWKH
FRQQHFWRULVGLVFRQQHFWHGRUFRQQHFWHGUDGLRJUDSK\PD\EHFRPHLPSRVVLEOHRUQRUPDO
LPDJHVFDQQRWEHREWDLQHG
HINT
0RELOHH[SRVXUHVFDQEHPDGHE\FDUU\LQJWKHÀDWSDQHOVHQVRUQRWHERRNFRPSXWHU LPDJHSURFHVVLQJXQLW DQG
the optional access point.
Basic Operation
>@3RVLWLRQLQJWKHSDWLHQW
Position the patient.
CAUTIONS
 [HUFLVHGXHFDUHVRWKDWDQLQWUDYHQRXVOLQHRUGUDLQWXEHSXWWRDSDWLHQWGRHVQRWKRRNLQWR
WKHHTXLSPHQW
For the exposure position of the upright-type/bed-type radiographic examination stand, see its Operation Manual.
:KHQPDNLQJDQH[SRVXUHGLUHFWO\XVLQJWKHÀDWSDQHOVHQVRU
set the exposure position by reference to the effective area.
Effective area
For details on the effective area, see page A-6.
When the automatic X-ray detection function is used, see “Z.5 Precautions for the Automatic X-ray
Detection Function”.
FDR D-EVO II Operation Manual
897N120339A
3-17
>@;UD\H[SRVXUH,PDJHGLVSOD\LQJ
0DNHDQH[SRVXUHDIWHUFRQÂżUPLQJWKDW6KRW5HDG\ H[SRVXUHUHDG\VWDWXVLQGLFDWRU LVOLWJUHHQLQWKHFRQQHFWHG
GHYLFHVVWDWXVRIWKHLPDJHSURFHVVLQJXQLW:KHQWKHDXWRPDWLF;UD\GHWHFWLRQIXQFWLRQLVXVHGLIWKHÀDWSDQHO
sensor is subjected to X-ray radiation without ShotReady lit in green, no image will be acquired although X-ray
radiation is applied.
$IWHU WKH H[SRVXUH GR QRW PRYH WKH LPDJH SURFHVVLQJ XQLW DQG WKH ÀDW SDQHO VHQVRU XQWLO D SURFHVVHG LPDJH
appears in the window of the image processing unit.
Basic Operation
Touch the
button at the lower right to complete the study.
To prepare for exposures of the next patient, repeat Step 1 through Step 3 .
(1)
The registration of the next new patient should be processed after more than 2 seconds.
3-18
FDR D-EVO II Operation Manual
897N120339A
[3] Sleep mode
When sleep mode is enabled, if no operation is performed for about two minutes without an exposure menu
UHJLVWHUHGWKHÀDWSDQHOVHQVRUZLOOHQWHUVOHHSPRGHDQGWKHSRZHUVWDWHLVFKDQJHGWRWKHSRZHUVDYLQJVWDWH
Once an exposure menu is registered, sleep mode is canceled automatically. In addition, when the SE cable is
FRQQHFWHGWRWKHÀDWSDQHOVHQVRURUZKHQWKHÀDWSDQHOVHQVRULVLQVHUWHGLQWRWKHGRFNLQJVWDQGVOHHSPRGHLV
canceled automatically.
([WUDVOHHSPRGHZKLFKFDQIXUWKHUVDYHSRZHUFDQDOVREHVHW,IDVSHFL¿HGWLPHKDVHODSVHGDIWHUDOOÀDWSDQHO
sensors enter sleep mode, they enter extra sleep mode. When the sleep release/memory exposure mode start
button is pressed, extra sleep mode is canceled.
In sleep mode or extra sleep mode, the operating time of the battery pack becomes longer since the power is saved.
,IWKHÀDWSDQHOVHQVRULVEHLQJFDOLEUDWHGRULILWGHWHFWVDQLPSDFWLWPD\WDNHORQJHUWLPHWRHQWHUVOHHSPRGH
or sleep mode may be canceled temporarily. When the setting of sleep mode or extra sleep mode needs to be
FKDQJHGFRQVXOWRXURIÂżFLDOGHDOHURUORFDOUHSUHVHQWDWLYH
>@([WHQGHG,PDJH5HDGRXW
FDR D-EVO II Operation Manual
897N120339A
Basic Operation
When the Extended Image Readout mode is enabled, a long exposure for up to ten seconds is available. To set the
([WHQGHG,PDJH5HDGRXWPRGHFRQVXOWRXURIÂżFLDOGHDOHURUORFDOUHSUHVHQWDWLYH)RUGHWDLOVRQKRZWRXVHWKH
Extended Image Readout mode, see the “Console Advance (DR-ID 300CL) Reference Guide”.
3-19
3.4 How to Use Memory Exposure Mode
,QWKHPHPRU\H[SRVXUHPRGHDPD[LPXPRIH[SRVXUHVFDQEHPDGHRQO\ZLWKWKHÀDWSDQHO
sensor, without using the image processing unit.
3.4.1 How to Start up and Use Memory Exposure Mode
HINT
Press and hold the memory exposure mode
VWDUWEXWWRQDQGWKHVOHHSUHOHDVHPHPRU\
exposure mode start button at the same
time for 2 seconds.
Memory
exposure
mode status
Sleep release/
memory exposure
mode start button
When the memory exposure mode is started up, the
ÀDWSDQHOVHQVRUHQWHUV;UD\GHWHFWLRQPRGH
For details on X-ray detection mode, see “Z.5
Precautions for the Automatic X-ray Detection
Function”.
2
Status lamp
:KHQWKH5($'<ODPSDPRQJWKHVWDWXV
ODPSVLVDXWRPDWLFDOO\OLWLQJUHHQPDNHDQ
exposure.
Basic Operation
READY
Memory exposure mode start button
:KHQWKHQXPEHURILPDJHVVWRUHGRQWKHÀDWSDQHO
sensor is displayed in the memory exposure mode
status, the start-up process is completed.
3
0DNHVXUHWKDWWKHQXPEHURILPDJHV
displayed in the memory exposure mode
status has increased.
HINT
Before the start-up process is completed, calibration
RIWKHÀDWSDQHOVHQVRUPD\EHSHUIRUPHG
During calibration, “888” blinks in the memory
exposure mode status.
When the READY lamp among the status lamps is
automatically lit in green, the next exposure can be
made.
HINT
When calibration is completed, the number of
LPDJHVVWRUHGRQWKHÀDWSDQHOVHQVRULVGLVSOD\HG
The value displayed as the number of images is
used for managing the images.
For example, when “3” is displayed before an
exposure and then “4” is displayed after the
exposure, the number of the exposed image is “4”.
CAUTIONS
When the memory exposure mode is started
XSZKLOHWKHÀDWSDQHOVHQVRULVLQXVH
DPHVVDJHLVGLVSOD\HGRQWKHVFUHHQRI
WKHLPDJHSURFHVVLQJXQLWLQGLFDWLQJWKDW
communication is disconnected. Since this is
QRWDQHUURUVHOHFW³2.´WRFRQWLQXHRSHUDWLRQ
+RZHYHULIWKHIROORZLQJHUURUFRGHVDUH
GLVSOD\HGWDNHDSSURSULDWHPHDVXUHV
DFFRUGLQJWRWKHLQVWUXFWLRQVGLVSOD\HGRQWKH
VFUHHQ;;; HUURUFRGHVEHJLQQLQJZLWK
³´ RU
3-20
FDR D-EVO II Operation Manual
897N120339A
CAUTIONS
Ɣ 1
 RWHWKDWZKHQWKHÀDWSDQHOVHQVRULV
used in the memory exposure mode, if a
VWURQJLPSDFWLVDSSOLHGWRWKHÀDWSDQHO
VHQVRUDZKLWHLPDJHPD\EHREWDLQHG
LQFUHPHQWLQJWKHQXPEHURILPDJHV
Ɣ 0
 DQDJHWKHUHFRUGVRIH[SRVHGLPDJHVWR
identify the correspondence between the
LPDJHQXPEHUDQGWKHSDWLHQWQDPH
 +RZWR/RDG,PDJHV
1
&RQQHFWLQVHUWWKHÀDWSDQHOVHQVRUWRLQWR
each device.
:KHQFDOLEUDWLRQRIWKHÀDWSDQHOVHQVRULVLQ
progress, an error may occur.
If this happens, wait for a while and then try image
loading again.
(When the DR-ID 1200PU is used)
&RQQHFWWKHÀDWSDQHOVHQVRUWRWKHSRZHUVXSSO\
unit using the SE cable.
Flat panel sensor
3
'LVSOD\WKH³6WXG\VFUHHQ´RIWKHSDWLHQW
FRUUHVSRQGLQJWRWKHORDGHGLPDJHVDQG
VHOHFWWKHH[SRVXUHPHQXWREHOLQNHGZLWK
WKHLPDJHV
4
6HOHFWWKHVHOHFWRURIWKHÀDWSDQHOVHQVRU
LQZKLFKWKHLPDJHLVVWRUHGDQGWKHQVHOHFW
>,PDJH%R[@
Power supply unit
5
2QWKH³,PDJH/LEUDU\VFUHHQ´VHOHFWWKH
LPDJHRIZKLFKWKHQXPEHULVWREHOLQNHG
with the exposure menu and then select
[Import].
Basic Operation
(When the DR-ID 1200DU is used)
,QVHUWWKHÀDWSDQHOVHQVRULQWRWKHGRFNLQJVWDQG
)RUGHWDLOVRQKRZWRLQVHUWWKHÀDWSDQHOVHQVRU
into the docking stand, see “3.1.10 Attaching the
Flat Panel Sensor to the Docking Stand” on Page
3-8.
2
7RORDGLPDJHVVWRUHGRQWKHÀDWSDQHO
VHQVRULQWRWKHLPDJHSURFHVVLQJXQLW
GLVSOD\WKH³,PDJH5HDGHU6WDWXVZLQGRZ´
RQWKHLPDJHSURFHVVLQJXQLWVHOHFWWKHÀDW
SDQHOVHQVRUDQGWKHQ³*HW,PDJH )3'Æ
&6/ ´
HINT
When an image that has not been linked with an
exposure menu is left, if images are acquired from
WKHÀDWSDQHOVHQVRUWKHDFTXLVLWLRQGDWHDQGWLPH
is added to the image No. of the image that was
acquired previously.
For details, see the “Console Advance (DR-ID
300CL) Reference Guide”.
,PDJHVVWRUHGLQWKHÀDWSDQHOVHQVRUDUHORDGHG
onto the image processing unit.
FDR D-EVO II Operation Manual
897N120339A
3-21
3.4.3 List of Error Codes
If an error occurs while starting up or using the memory exposure mode, the corresponding error
code is displayed in the memory exposure mode status. Terminate the memory exposure mode and
then perform the countermeasure against each error. Error codes are listed in the table below.
Error code
Occurrence condition
E01
Countermeasure
Basic Operation
&DOLEUDWLRQRIWKHÀDWSDQHOVHQVRULV
in progress.
Wait for a while and then start up the memory
exposure mode again.
An exposure menu is registered on
the image processing unit.
Terminate or suspend the study on the image
processing unit.
The SE cable or SE communication
FDEOHLVFRQQHFWHGWRWKHÀDWSDQHO
sensor.
Disconnect the SE cable or SE communication
FDEOHIURPWKHÀDWSDQHOVHQVRU
7KHÀDWSDQHOVHQVRULVLQVHUWHGLQWR
the docking stand.
5HPRYHWKHÀDWSDQHOVHQVRUIURPWKHGRFNLQJ
stand.
E03
An X-ray is irradiated when exposure
is not available.
&RQQHFWWKHÀDWSDQHOVHQVRUWRWKHLPDJH
processing unit or remove and attach the
battery pack and then restart the memory
exposure mode.
E04
7KHÀDWSDQHOVHQVRUGHWHFWVDQ
impact.
&RQQHFWWKHÀDWSDQHOVHQVRUWRWKHLPDJH
processing unit.
E05
The remaining capacity of the battery
pack is low.
Replace the battery pack.
E06, E07, E17, E18 7KHWHPSHUDWXUHRIWKHÀDWSDQHO
sensor or battery back is abnormal.
Check if the operating temperature is within
WKHWHPSHUDWXUHUDQJHVSHFLÂżHGLQWKH
environmental operating conditions.
E08, E09, E11 to
E14, E16, E19
$QDEQRUPDOLW\RFFXUUHGRQWKHÀDW
panel sensor.
&RQVXOWRXURIÂżFLDOGHDOHURUORFDO
representative.
E10
Calibration has failed.
Restart the memory exposure mode.
E15
Image storage has failed.
&RQVXOWRXURIÂżFLDOGHDOHURUORFDO
representative.
,IWKHVDPHHUURURFFXUVUHSHDWHGO\FRQVXOWRXURIÂżFLDOGHDOHURUORFDOUHSUHVHQWDWLYH
3.4.4 How to Terminate Memory Exposure Mode
(DR-ID 1200PU)
5HPRYHWKHEDWWHU\SDFNIURPWKHÀDWSDQHOVHQVRU
2UFRQQHFWWKHÀDWSDQHOVHQVRUWRWKHSRZHUVXSSO\XQLWRUWRWKHRSWLRQDODFFHVVSRLQWE\XVLQJ
the SE cable or SE communication cable.
(DR-ID 1200DU)
5HPRYHWKHEDWWHU\SDFNIURPWKHÀDWSDQHOVHQVRU
2ULQVHUWWKHÀDWSDQHOVHQVRULQWRWKHGRFNLQJVWDQG
HINT
,PDJHVH[SRVHGLQWKHPHPRU\H[SRVXUHPRGHDUHQRWORVWHYHQLIWKHEDWWHU\SDFNLVUHPRYHGIURPWKHÀDWSDQHO
sensor.
3-22
FDR D-EVO II Operation Manual
897N120339A
Chapter 4
7URXEOHVKRRWLQJ
4.1 :KHQD0HVVDJH$SSHDUVRQWKH,PDJH
3URFHVVLQJ8QLW
This section describes the warning dialog box and error messages.
,IDQHUURUZKLFKFDQQRWEHKDQGOHGRUWKHVDPHHUURUUHFXUVIUHTXHQWO\FRQWDFWRXURIÂżFLDOGHDOHURU
FUJIFILM Representative.
,IDQHUURURIXQNQRZQFDXVHRFFXUVGRQRWFRQWLQXHWKHRSHUDWLRQDQGFRQWDFWRXURIÂżFLDOGHDOHURU
FUJIFILM Representative.
>@,IDZDUQLQJGLDORJER[DSSHDUV
If a communication error or an unexpected error has occurred, a warning dialog box pops up on
the screen. In such a case, after checking error details and closing the box, take appropriate action
immediately. Be sure not to continue the operation of the image processing unit without taking an
appropriate action.
If any operation is performed while a warning dialog box is displayed, another screen may be
displayed, hiding the dialog box behind. In this case, press the [Enter] key to close the hidden box.
When a warning dialog box that contains an error code beginning with “10” appears, follow the
steps below.
5HDGDPHVVDJHLQWKHZDUQLQJGLDORJER[DQGWKHQFOLFN>2.@LQWKHGLDORJER[
2
'HWDFKWKHEDWWHU\SDFNVIRUDOOÀDWSDQHOVHQVRUV
3
&RQ¿UPWKDWWKHÀDWSDQHOVHQVRUVDUHWXUQHGRII
4
5HDWWDFKWKHEDWWHU\SDFNVWRWKHÀDWSDQHOVHQVRUV7KHQWKHV\VWHPUHVWDUWV
Troubleshooting
1
>@,IWKHPHVVDJHGLDORJXHER[0'DSSHDUV
The following message dialogue box appears not only when the image processing unit starts up but
DOVRZKHQDFRPPXQLFDWLRQHUURURFFXUVLQWKHÀDWSDQHOVHQVRURULPDJHSURFHVVLQJXQLW
&KHFNLIWKHÀDWSDQHOVHQVRULVZLWKLQWKHUHDFKRIUDGLRZDYHV,IWKHXQLWLVRXWRIWKHUDQJHPRYH
WKHLPDJHSURFHVVLQJXQLWDQGWKHÀDWSDQHOVHQVRUFORVHUWRHDFKRWKHU
,QDGGLWLRQFRQÂżUPWKDWWKHUHDUHQRREVWDFOHVZKLFKDUHLQWHUUXSWLQJWKHFRPPXQLFDWLRQ
When the problem is not solved within a short time after the message box is displayed, perform the
following procedure.
FDR D-EVO II Operation Manual
897N120339A
4-1
 KHQ DFTXLULQJ GDWD LV LQWHUUXSWHG WKH LPDJH GDWD LV PDLQWDLQHG LQ WKH ÀDW SDQHO VHQVRU LI UHFRQQHFWLRQ LV
VXFFHVVIXOO\PDGHRUXQWLOSRZHUVXSSO\RIÀDWSDQHOVHQVRULVWXUQHGRIIVRLPDJHGDWDZLOOQRWEHORVW
,QWKHFDVHRIWKHPHPRU\H[SRVXUHPRGHLPDJHVVWRUHGLQWKHÀDWSDQHOVHQVRUDUHQRWORVWHYHQLIWKHÀDWSDQHO
sensor is turned off.
1
6HOHFW>2.@RQWKHPHVVDJHER[
2
&KHFNLIWKHHTXLSPHQWFRQQHFWHGZLWKWKHLPDJHSURFHVVLQJXQLWLVWXUQHGRQ
If any equipment is turned off, turn it on and wait for a while.
3
,IWKHSUREOHPLVQRWVROYHGVKXWGRZQWKHLPDJHSURFHVVLQJXQLW
4
0DNHVXUHWKDWWKHSRZHUVWDWXV/('RIWKHFRQWUROFDELQHWLVRIIDQGWKHQUHVWDUWWKHLPDJH
SURFHVVLQJXQLW
This step is not required if the control cabinet is not included in the system.
If the power status LED of the control cabinet does not turn off even after approximately 10 minutes have passed
following the shutdown of the image processing unit, press and hold the main switch of the control cabinet.
7URXEOHVKRRWLQJ
 KHQWKHLPDJHSURFHVVLQJXQLWLVUHVWDUWHGDQGWKHVDPHHUURUPHVVDJHER[LVGLVSOD\HGFRQWDFWRXURIÂżFLDO
dealer or FUJIFILM Representative.
>@,IDQH[SRVHGLPDJHFDQQRWEHDFTXLUHG
'RQRWUHPRYHWKHEDWWHU\SDFNIURPWKHÀDWSDQHOVHQVRUXQWLODQH[SRVHGLPDJHLVDFTXLUHG,IUHPRYHGWKH
image data and the exposure menu data used for the exposure will be lost.
If an exposed image cannot be acquired, the following error message may be displayed.
1
,IZLUHOHVVFRPPXQLFDWLRQLVGLVFRQQHFWHGGXULQJLPDJHUHDGLQJWKHIROORZLQJPHVVDJHGLDORJ
is displayed.

0RYH WKH ÀDW SDQHO VHQVRU FORVH WR WKH DFFHVV SRLQW FKHFN WKH GLVSOD\HG LFRQ (
) to
make sure that proper wireless communication is established, and then select “Yes”. If the status is
QRWLPSURYHGFRQQHFWWKHÀDWSDQHOVHQVRUDQGWKHDFFHVVSRLQWXVLQJWKH6(FRPPXQLFDWLRQFDEOH
and then select “Yes”. If you select “No”, the image data and the exposure menu data used for the
exposure will be lost.
4-2
FDR D-EVO II Operation Manual
897N120339A
2
If an exposure is made under a condition where wireless communication is unstable, the
IROORZLQJPHVVDJHGLDORJPD\EHGLVSOD\HG6HOHFW³2.´WRDFTXLUHWKHLPDJHDQGWKHQFKHFN
WKHDFTXLUHGLPDJH

>@,IWKHGLDORJER[FRQWDLQLQJWKHHUURUPHVVDJHQXPEHUHG
13048 appears
7KHGLDORJXHER[DSSHDUVZKHQDVHYHUHVKRFNLVDSSOLHGWRWKHÀDWSDQHOVHQVRU0DNHVXUHWKDW
WKHH[WHULRURIWKHÀDWSDQHOVHQVRULVQRWGDPDJHGRUGHIRUPHGDQGWKDWQRDEQRUPDOLW\LVIRXQGLQ
the exposed image.
Troubleshooting
[5] ,I³8QXVDEOHGXHWRHUURU´DSSHDUVRQWKHLPDJHSURFHVVLQJXQLW
Connected devices status
FDR D-EVO II Operation Manual
897N120339A
4-3
If “Unusable due to error.” is displayed on the image processing unit, remove the battery pack from
WKHÀDWSDQHOVHQVRUDQGLQVWDOOLWDJDLQ
Guide marks
Battery pack
>@,IDQ\RWKHUPHVVDJHGLDORJXHER[DSSHDUV
If a message dialogue box other than those [1] – [5] appears on the image processing unit monitor,
read the message carefully and take appropriate action.
Troubleshooting
4-4
FDR D-EVO II Operation Manual
897N120339A
4.2 How to Cope with an Error...
>@:KHQWKHLPDJHSURFHVVLQJXQLWKDQJVXSÂŤ
If an inappropriate processing is performed while this equipment is operating, the screen may freeze
and the system may hang up (processing disabled). In that case, shut down the equipment forcibly
according to the following procedure, and then restart it.
1
3UHVVWKH>&WUO@>$OW@>'HO@NH\VVLPXOWDQHRXVO\
2
³:LQGRZV6HFXULW\´LVGLVSOD\HG
Select [Start Task Manager].
3
³:LQGRZV7DVN0DQDJHU´LVGLVSOD\HG
Select “ProcessManagerMain.exe” in the list in the “Processes” tab, and then click [End Process].
4
7KHPHVVDJHER[LVGLVSOD\HG
Click [End Process] to terminate the image processing unit.
Depending on equipment status, an error message may not be displayed.
Troubleshooting
5
7KHGHVNWRSVFUHHQRIWKHRSHUDWLQJV\VWHPLVGLVSOD\HG
Close the “Windows Task Manager window”, and then select the [Start] button at the lower left of the screen. Select
[Restart] from the displayed menu.
CAUTIONS
Ɣ 0DNHVXUHWRVKXWGRZQWKHV\VWHPIROORZLQJWKHDERYHSURFHGXUHVLQFDVHRIDKDQJXSRI
WKHLPDJHSURFHVVLQJXQLW,IWKHSHUVRQDOFRPSXWHULVWXUQHGRIIZLWKRXWVKXWGRZQDQHUURU
may occur on the computer.
Ɣ 1RWHWKDWIRUFLEOHVKXWGRZQSURFHVVLQJRIWKHHTXLSPHQWLVDQHPHUJHQF\DFWLRQ'RQRWXVH
this action under normal situations.
If the control cabinet is included in the system, press and hold the main switch of the control
cabinet to turn it off.
7
7XUQRIIWKHPDLQVZLWFKRQWKHSRZHUVXSSO\XQLWDQGRQWKHGRFNLQJVWDQG
>@:KHQWKHLPDJHSURFHVVLQJXQLWLVWXUQHGRIIGXHWRDQ
HOHFWULFDORXWDJH
When the image processing unit is turned off due to an electrical outage, etc., take the following
actions according the condition when the power comes back on.
Ĺś ,IWKHSRZHUFRPHVEDFNRQVRRQDIWHUDQHOHFWULFDORXWDJH
Wait until the image processing unit restarts.
When the image processing unit has restarted, shut down the image processing unit by following
the normal procedure.
For details of system shutdown, see the “DR-ID 300CL Operation Manual”.
To restart the image processing unit, follow the procedure for the system startup.
FDR D-EVO II Operation Manual
897N120339A
4-5
>@,IDKDUGGLVNRIWKHLPDJHSURFHVVLQJXQLWLVGDPDJHG
If one of the hard disks is damaged, a window indicating so will appear. In such a case, press the
)NH\DQGFRQWDFWRXURIÂżFLDOGHDOHU
>@,IDZKLWHLPDJHLVGLVSOD\HGDIWHUDQH[SRVXUH
If a white image is displayed, a LAN communication error may have occurred.
&KHFNLIWKH/$1FRPPXQLFDWLRQFRQQHFWRUVDUHSURSHUO\FRQQHFWHGEHWZHHQWKHÀDWSDQHOVHQVRU
and the power supply unit or and between the power supply unit and the control cabinet. Make an
H[SRVXUHDJDLQDIWHUFRQÂżUPDWLRQ
[5] Precautions for operation when the device status is
³,QLWLDOL]LQJ´RU³&KDQJLQJ)3'´LQWKHLPDJHSURFHVVLQJ
XQLWœV³2XWSXW'HYLFH6WDWXVZLQGRZ´
:KHQDÀDWSDQHOVHQVRULVDGGHGRUUHSODFHGRUZKHQWKHEDWWHU\RIDÀDWSDQHOVHQVRULVUHSODFHG
³,QLWLDOL]LQJ´RU³&KDQJLQJ)3'´LVGLVSOD\HGIRUDOOWKHÀDWSDQHOVHQVRUVLQWKHGHYLFHVWDWXV¿HOGRI
the image processing unit’s “Output Device Status window”. While either of the status messages is
displayed, you cannot make an exposure. Wait until the message disappears.
:KHQWKHÀDWSDQHOVHQVRULVWXUQHGRQE\FRQQHFWLQJWKHFDEOHIRUZLUHGFRPPXQLFDWLRQRUE\
attaching the battery pack immediately after the system starts up or an X-ray exposure is made, it
may take time before the next exposure becomes available.
Troubleshooting
(YHQLI³,QLWLDOL]LQJ´RU³&KDQJLQJ)3'´LVGLVSOD\HGIRUDOOWKHÀDWSDQHOVHQVRUVRQO\WKRVHZKLFKDUHDGGHGRU
replaced or those whose battery is replaced will be initialized.
>@,IWKHÀDWSDQHOVHQVRUFDQQRWEHXVHGLQZLUHOHVV
communication mode
,IWKHÀDWSDQHOVHQVRULVQRWUHFRJQL]HGLQDZLUHOHVVFRPPXQLFDWLRQPRGHXVHWKHFDEOHWR
connect the system in wired communication mode.
4-6
FDR D-EVO II Operation Manual
897N120339A
[7] If an error occurs on an output destination device
If an error occurs on an output destination device,
In such a case, operate as follows.
Select
is displayed in the connected devices status.
The “Output Device Status window” is displayed.
Select
after checking the connection status, and then take an appropriate action.
7URXEOHVKRRWLQJ
“Output Device Status window“
FDR D-EVO II Operation Manual
897N120339A
4-7
4
Troubleshooting
4-8
FDR D-EVO II Operation Manual
897N120339A
Chapter 5
Daily Inspection and
Maintenance
5.1 Daily User Inspection and Maintenance
During maintenance and inspection, strictly observe precautions contained in “Chapter 1 For Safe
Operation” in this manual for you to use the FDR D-EVO II under best conditions.
5.1.1 Daily Inspection (DR-ID 1200)
Inspection Before Use
• Make sure that the equipment starts up normally.
• Make sure that the equipment communicates with connected devices normally.
• Make sure that the time displayed is correct.
See “3.2 Starting Up and Shutting Down the System” (page 3-9).
,QVSHFWLRQ'XULQJ8VH
• Make sure that images are output normally.
See “3.3 Routine Operations” (page 3-13).
Daily Inspection and Maintenance
Inspection After Use
• Shut down the equipment.
See “3.2 Starting Up and Shutting Down the System” (page 3-9).
&OHDQLQJLQVWUXFWLRQV
Use a neutral detergent or ethanol to clean the outer surfaces.
CAUTIONS
Ɣ Do not use a solvent such as thinner or benzine, as it corrodes the outer surfaces.
Ɣ 0DNHVXUHQRWWROHWZDWHUGHWHUJHQWDQGHWKDQROJHWLQVLGHWKHHTXLSPHQW
FDR D-EVO II Operation Manual
897N120339A
5-1
5.1.2 Periodical Inspection
Inspection Every Three Months
Once every three months, remove any dirt or dust accumulated in each part of the equipment using
a vacuum cleaner or air duster, clean each part with a slightly moistened soft cloth and then wipe off
any moisture with a dry cloth.
See “2.2 Unit Names and the Functions” (page 2-4).
CAUTIONS
%HVXUHWRWXUQRIIWKHSRZHUEHIRUHFOHDQLQJHDFKSDUWRIWKHGHYLFH
Ĺś DR-ID 1200
DR-ID 1200
NO.
Unit
NO.
Flat panel sensor
Unit
NO.
Power supply unit
Unit
Power supply unit
$LUÂżOWHU 
NO.
$LUÂżOWHU
&OHDQWKHDLUÂżOWHURQWKHUHDURIWKHSRZHU
supply unit with a vacuum cleaner.
Remove the louver while pressing the lever
RQWKHULJKWVLGHDQGWKHQFOHDQWKHDLUÂżOWHU
with a vacuum cleaner after detaching it from
the louver.
Daily Inspection and Maintenance
Unit
NO.
Control cabinet
Unit
Periphery of
devices
Optional
NO.
Unit
NO.
Battery charger
Unit
Battery pack
NO.
Unit
Access Point
CAUTIONS
Ɣ (QVXUHVXI¿FLHQWVSDFHZKHQFOHDQLQJWKHHTXLSPHQWRQDWDEOHHWF
Ɣ ,IWKHLPDJHSURFHVVLQJXQLWLVVHFXUHGLQSODFHXQORFNLWEHIRUHFOHDQLQJ
5-2
FDR D-EVO II Operation Manual
897N120339A
Image processing
unit
Air filter
DR-ID 1200MC
NO.
Unit
Appendix A
Specifications
A.1 Specifications
6SHFLÂżFDWLRQVRIWKH)'5D-EVO II are shown below.
$ 3URFHVVLQJ&DSDFLW\ '5,'
Ĺś 5RXWLQHSURFHVVLQJ ZKHQWKHWZRLPDJHRXWSXWIRUPDWLVXVHGLQ
standard mode)
(1) Exposure interval
The exposure interval of the FDR D-EVO II is at least 9 seconds.
However, the interval varies depending on the region, the load to network communication, etc.
$ ,PDJH2XWSXW '5,'
Ĺś 6WDQGDUGSURFHVVLQJ
(1) Film output
Connection to the Imager makes it possible to obtain hard copies at the image reduction ratios
and in the formats below.
Ɣ)RUVWDQGDUGSL[HOGHQVLW\LPDJHV '5,'6(DQG'5,'6(
Output size
2QHLPDJHRXWSXW
61%
61%
85%
100%
100%
100%
100%
100%
100%
100%
Appendix A Specifications
14” × 17” (35 × 43cm)
14” × 14” (35 × 35cm)
10” ×12”
8” × 10”
18 × 43cm
Reduction ratio
7ZRLPDJHRXWSXW
Ɣ)RUVWDQGDUGSL[HOGHQVLW\LPDJHV '5,'6(DQG'5,'6( 
Output size
17” × 17” (43 × 43cm)
14” × 17” (35 × 43cm)
14” × 14” (35 × 35cm)
10” × 12”
8” × 10”
18 × 43cm
Reduction ratio
7ZRLPDJHRXWSXW
2QHLPDJHRXWSXW
50%
61%
61%
85%
100%
100%
82%
100%
100%
100%
100%
100%
FDR D-EVO II Operation Manual
897N120339A
A-1
[Fig. A.1]
(a) 14” × 17”
one-image output
(b) 17” × 14”
one-image output
(c) 14” × 14”
one-image output
ID information
ID information
Image
Image
Image
(14” × 17” film)
ID information
(14” × 17” film)
(14” × 17” film)
(d) 18 × 43cm
one-image output
(e) 18 × 43cm
two-image output
ID
information
Image
Image
Image
(f) 18 × 43cm
two-image output
ID
information
Image
Image
ID
information
(14” × 17” film)
(26 × 36cm film)
ID
information
(26 × 36cm film)
(g) Two-image output
Image
ID information
(26 × 36cm film)
For one-image output using 17” × 14”, 14” × 17”, 14” × 14” or 18 × 43cm, images are output on 14”
î´¿OP,QRWKHUFDVHVLPDJHVDUHRXWSXWRQîFP¿OP
Appendix A Specifications
Depending on the printer connected or image processing unit software version used, image outputs in the
following formats are available.
‡VL]HRXWSXWRI´î´LPDJHRQ´î´¿OP
‡VL]HRXWSXWRI´î´LPDJHRQ´î´¿OPDVZHOODVUHGXFHGLPDJHRXWSXWRQ¿OPVRIRWKHUVL]HV
‡VL]HRXWSXWRI´î´LPDJHRQ´î´¿OP
$ 5HGXFHG(TXLYDOHQW
3HDNUHGXFHGHTXLYDOHQWRQWKHIURQWSDQHORIWKHÀDWSDQHOVHQVRUPP$O
A-2
FDR D-EVO II Operation Manual
897N120339A
A.1.4 Power Supply Conditions
Ĺś DR-ID 1200PU
 5DWHGYROWDJH9a
 ,QSXWFXUUHQW $
 )UHTXHQF\ +]
Ĺś DR-ID 1200DU
 5DWHGYROWDJH9a
 ,QSXWFXUUHQW $
 )UHTXHQF\ +]
Ĺś DR-ID 1200MC*
 5DWHGYROWDJH9a
 ,QSXWFXUUHQW $
 )UHTXHQF\ +]
* Since the DR-ID 1200MC is general-purpose electrical equipment, the electric rating above is an example.
A.1.5 Environmental Conditions
Ĺś DR-ID 1200PU
 2SHUDWLQJ&RQGLWLRQV
 7HPSHUDWXUH
ƒ& 5+ ƒ& 5+
 +XPLGLW\
5+ ƒ& 5+ ƒ&  QRGHZFRQGHQVDWLRQ
 $WPRVSKHULFSUHVVXUHK3DK3D
 1RQRSHUDWLQJ&RQGLWLRQV
(Environmental conditions under which power can be supplied)
 7HPSHUDWXUH
ƒ&ƒ&
 +XPLGLW\
5+5+ QRGHZFRQGHQVDWLRQ
 $WPRVSKHULFSUHVVXUHK3DK3D
Appendix A Specifications
 6WRUDJH&RQGLWLRQV
 7HPSHUDWXUH
ƒ&ƒ&
 +XPLGLW\
5+5+ QRGHZFRQGHQVDWLRQ
 $WPRVSKHULFSUHVVXUHK3DK3D
Ĺś DR-ID 1200DU
 2SHUDWLQJ&RQGLWLRQV
 7HPSHUDWXUH
ƒ& 5+ ƒ& 5+
 +XPLGLW\
5+ ƒ& 5+ ƒ&  QRGHZFRQGHQVDWLRQ
 $WPRVSKHULFSUHVVXUHK3DK3D
 1RQRSHUDWLQJ&RQGLWLRQV
(Environmental conditions under which power can be supplied)
 7HPSHUDWXUH
ƒ&ƒ&
 +XPLGLW\
5+5+ QRGHZFRQGHQVDWLRQ
 $WPRVSKHULFSUHVVXUHK3DK3D
 6WRUDJH&RQGLWLRQV
 7HPSHUDWXUH
ƒ&ƒ&
 +XPLGLW\
5+5+ QRGHZFRQGHQVDWLRQ
 $WPRVSKHULFSUHVVXUHK3DK3D
FDR D-EVO II Operation Manual
897N120339A
A-3
CAUTIONS
Ɣ :
 KHQWKHÀDWSDQHOVHQVRULVXVHGLQKLJKWHPSHUDWXUHFRQGLWLRQIRUORQJSHULRGRIWLPHLW
PD\FDXVHLPDJHDUWLIDFWVDQGRUIDLOXUHRIWKHGHYLFH
Ɣ :
 KHQXVLQJWKH'5,'6(RU'5,'6(LIWKHWHPSHUDWXUHLVž&DQGWKHKXPLGLW\
LV5+ QRGHZFRQGHQVDWLRQ FRQWLQXRXVXVHRIPLQXWHVRUOHVVLVSRVVLEOH
 8
 VLQJ0DQXDO0RGH HQHUJ\VDYLQJPRGH IURPWKHLPDJHSURFHVVLQJXQLWZKHQWKH
temperature and humidity are the same allows up to 1 hour of continuous use.
Ĺś DR-ID 1200MC
 2SHUDWLQJ&RQGLWLRQV
 7HPSHUDWXUH
ƒ&ƒ&
 +XPLGLW\
5+5+ QRGHZFRQGHQVDWLRQ
 $WPRVSKHULFSUHVVXUHK3DK3D
 1RQRSHUDWLQJ&RQGLWLRQV
(Environmental conditions under which power can be supplied)
 7HPSHUDWXUH
ƒ&ƒ&
 +XPLGLW\
5+5+ QRGHZFRQGHQVDWLRQ
 $WPRVSKHULFSUHVVXUHK3DK3D
For details on the power supply conditions and environmental conditions of the image processing unit, see the
“Console Advance (DR-ID 300CL) Operation Manual”.
Ĺś %DWWHU\FKDUJHU RSWLRQDO
 2SHUDWLQJ&RQGLWLRQV
 7HPSHUDWXUH
ƒ&ƒ&
 +XPLGLW\
5+5+ QRGHZFRQGHQVDWLRQ
Appendix A Specifications
 1RQRSHUDWLQJ&RQGLWLRQV
(Environmental conditions under which power can be supplied)
 7HPSHUDWXUH
ƒ&ƒ&
 +XPLGLW\
5+5+ QRGHZFRQGHQVDWLRQ
CAUTIONS
&KDUJHWKHEDWWHU\SDFNLQWKHRSHUDWLQJHQYLURQPHQW
A-4
FDR D-EVO II Operation Manual
897N120339A
$ ([WHUQDO9LHZDQG:HLJKW
The external view and weight of the FDR D-EVO II are shown below.
6SHFLÂżFDWLRQVGLPHQVLRQVDQGZHLJKWDUHVXEMHFWWRFKDQJHIRULPSURYHPHQWZLWKRXWSULRUQRWLFH
A.2.1 DR-ID 1200
Ĺś '5,'38'5,''8
Width
(mm(in.))
Depth (mm(in.))
+HLJKW
(mm(in.))
:HLJKW
NJ OE
Flat panel sensor (DR-ID 1201SE)
460(18.1)
384(15.1)
15(0.6)
2.6(5.8)*1
Flat panel sensor (DR-ID 1202SE)
460(18.1)
460(18.1)
15(0.6)
3.2(7.1)*1
Flat panel sensor (DR-ID 1211SE)
460(18.1)
384(15.1)
15(0.6)
2.6(5.8)*1
Flat panel sensor (DR-ID 1212SE)
460(18.1)
460(18.1)
15(0.6)
3.2(7.1)*1
Power supply unit
120(4.7)
388(15.3)*2
361(14.2)
8.7(19.2)
Docking stand
579(22.8)
93(3.7)
202(8.0)
5.5(12.1)
*1 The weight of the battery pack is included.
*2 Protrusions are excluded
8QLWPP LQ
459.9(18.1)
15(0.6)
459.9(18.1)
Flat panel sensor (DR-ID 1201SE)
Flat panel sensor (DR-ID 1202SE)
459.9(18.1)
15.5(0.6)
459.9(18.1)
15(0.6)
384(15.1)
460(18.1)
Flat panel sensor (DR-ID 1211SE)
Appendix A Specifications
384(15.1)
460(18.1)
15.5(0.6)
Flat panel sensor (DR-ID 1212SE)
FDR D-EVO II Operation Manual
897N120339A
A-5
8QLWPP LQ
8QLWPP LQ
120(4.7)
388(15.3)
93(3.7)
206.1(8.1)
361(14.2)
581(22.9)
Power supply unit
Docking stand
16.75
(0.66)
Appendix A Specifications
A-6
Effective
area
DR-ID 1201SE/DR-ID 1211SE
FDR D-EVO II Operation Manual
897N120339A
17.55
(0.69)
17.25
(0.68)
17.25
(0.68)
425.4(16.7)
17.25
(0.68)
Effective
area
424.8(16.7)
425.4(16.7)
17.55
(0.69)
17.25
(0.68)
350.4(13.8)
16.75
(0.66)
7KHHIIHFWLYHDUHDRIWKHÀDWSDQHOVHQVRULVDVVKRZQLQWKH¿JXUHEHORZ
DR-ID 1202SE/DR-ID 1212SE
Ĺś DR-ID 1200MC *
Control cabinet
Width
(mm(in.))
Depth
(mm(in.))
+HLJKW
(mm(in.))
:HLJKW
NJ OE
114(4.5)
353(13.9)
399(15.7)
8.3(18.3)
* The exterior, external dimensions and weight are examples since this is a general-purpose electric device.
8QLWPP LQ
353(13.9)
399(15.7)
114(4.5)
Control cabinet
Ĺś %DWWHU\FKDUJHU RSWLRQDO
Depth
(mm(in.))
+HLJKW
(mm(in.))
:HLJKW
NJ OE
Battery charger
92.5(3.6)
259(10.2)
56(2.2)
0.6(1.3)
AC adapter
153(6.0)
67(2.6)
35(1.4)
Approx.0.51(1.1)
Appendix A Specifications
Width
(mm(in.))
8QLWPP LQ
67(2.6)
35(1.4)
153(6.0)
AC adapter
259(10.2)
56(2.2)
92.5 (3.6)
Battery charger
FDR D-EVO II Operation Manual
897N120339A
A-7
Ĺś Access point (optional)
Access point
Width
(mm(in.))
Depth
(mm(in.))
+HLJKW
(mm(in.))
:HLJKW
NJ OE
39(1.5)
95(3.7)
27(1.1)
Less than approx.
0.1(0.2)
8QLWPP LQ
27(1.1)
39(1.5)
95(3.7)
Access point
Appendix A Specifications
A-8
FDR D-EVO II Operation Manual
897N120339A
A.3 Characteristics
(1) Sensitometoric Response Characteristics and Dynamic Range
FDR D-EVO II has a linear response against the exposure range where it can depict the clinical information.
7KHÀDWSDQHOVHQVRUFRYHUVDG\QDPLFUDQJHRIȝ*\DWOHDVWDW54$
(2) Spatial Resolution Properties
A typical MTF value of DR-ID 1201SE/DR-ID 1202SE at 1cyc/mm, RQA5 is 0.75 (high sharpness mode)
and 0.60 (standard sharpness mode).
A typical MTF value of DR-ID 1211SE/DR-ID 1212SE at 1cyc/mm, RQA5 is 0.80.
The level of uncertainty is estimated as less than Âą10%
  '4( 'HWHFWLYH4XDQWXP(IÂżFLHQF\
7\SLFDO'4(YDOXHRI'5,'6('5,'6(DWȝ*\LQF\FPPLV
7\SLFDO'4(YDOXHRI'5,'6('5,'6(DWȝ*\LQF\FPPLV
The level of uncertainty is estimated as less than Âą10%
(4) Display
To deliver the detector characteristics above, it is recommended to use a monitor with the following
VSHFLÂżFDWLRQV
 Ɣ,PDJHPDWUL[VL]H0LQLPXP[SL[HOV '5,'6('5,'6(
 Ɣ,PDJHPDWUL[VL]H0LQLPXP[SL[HOV '5,'6('5,'6(
 Ɣ*UD\VFDOH0LQLPXPELW
 Ɣ',&20FDOLEUDWHG
Appendix A Specifications
(5) Image Quality Evaluation
)XMLÂżOPW\SLFDOO\FRQGXFWVUHDGHUVWXGLHVWKDWFRPSDUHQHZ)'5'(92II detector models to chosen
PDUNHWHGGHYLFHV7KHVHVWXGLHVLQYROYLQJDQDVVHVVPHQWRILPDJHTXDOLW\E\ERDUGFHUWLÂżHGUDGLRORJLVWV
have demonstrated that the images acquired using the FDR D-EVO II detectors are deemed to be of
diagnostic capability. Additionally, reader studies have concluded that, when used in conjunction with
FUJIFILM’s recommended exposure conditions as a reference, both the GOS-based and Csl-based FDR
D-EVO II detectors can provide acceptable diagnostic capability and image quality at reasonably low dose
levels typically used for pediatric use.
(6) Typical Patient Dose
$VZLWKDQ\QHZSURGXFWDSSOLFDWLRQ)XMLÂżOPSURYLGHVDSSOLFDWLRQVWUDLQLQJVXSSRUWWRHDFKFXVWRPHU
to establish the dose levels that meet the image quality standards of the medical facility. As part of this
training, we provide both recommended technique charts as well as guidance for optimizing AEC conditions
for each detector type. When using any FDR D-EVO II detector, typical patient dose levels should not
H[FHHGWKDWRIVFUHHQÂżOPRU&RPSXWHG5DGLRJUDSK\
FDR D-EVO II Operation Manual
897N120339A
A-9
Appendix A Specifications
A-10
FDR D-EVO II Operation Manual
897N120339A
Appendix Z
Precautions for Exposure
Z.1 Precautions for Exposure in AUTO MODE
In AUTO MODE, stable image output can be obtained by means of the following.
 5DGLDWLRQÂżHOG
(2) EDR image data analysis
(3) Detailed depiction of the cervical region
However, problems may arise due to differences in the multiple diaphragms or scattered rays of the
;UD\HTXLSPHQW)RUVXFKSUREOHPVFRQWDFWRXURIÂżFLDOGHDOHURU)8-,),/05HSUHVHQWDWLYHDQGXVH
other recording modes, such as SEMI-AUTO MODE or FIX MODE.
Z.1.1 Radiation Field
1 'RQRWVHWWKHUDGLDWLRQÂżHOGH[WUHPHO\VPDOO%HVXUHWRVXEMHFWRQHWKLUGRUPRUHRIWKHOHQJWKRI
each side of the bucky of the DR system to X-ray exposure.
2 0DNHVXUHWKDWQRQHRIWKHVLGHVRIWKHUDGLDWLRQÂżHOGRYHUODSZLWKWKHFRQWUDVWPHGLXP(UURUVZLOO
result if they overlap.
 $YDLODEOHIRU(DFK$QDWRPLFDO5HJLRQ0HWKRG
Plain
Contrast Medium
7RPRJUDSK\
Head
1HFN
–
Chest
4 (1 for esophagus)
–
Abdomen
4 (1 for stomach and intestines)
–
Pelvis
–
Appendix Z Precautions for Exposure
3 Notes on PRIEF
[PRIEF 4]
Used, with some exceptions, for both plain and contrast medium exposure menus,
from the head to the pelvis.
The diaphragm shape will be any convex polygon, including rectangles, circles,
ellipses, tracks, etc.
[PRIEF 1]
Used with esophagus, stomach and intestines contrast medium menus.
FDR D-EVO II Operation Manual
897N120339A
Z-1
= 'HSLFWLRQRIWKH&HUYLFDO5HJLRQ
1 7KHUDGLDWLRQÂżHOGPXVWQRWLQFOXGHWKHZKROHKHDG%HVXUHWRVHFXUHWUDQVSDUHQWSRUWLRQVRQERWK
sides of the neck.
8VHWKH³+HDG´PHQXWRLQFOXGHWKHZKROHKHDGLQWKHUDGLDWLRQ¿HOG
2 )RUH[SRVXUHRIWKHSKDU\Q[RUODU\Q[EHVXUHWKDWWKHQHFNFRPHVWRWKHFHQWHURIWKHUDGLDWLRQÂżHOG
so that the frontal and lateral orientations can be recognized appropriately.
Image area
Radiation field
3 In pharynx and/or larynx exposure, do not use lead characters in the oblique line section.
Appendix Z Precautions for Exposure
= 'HSLFWLRQRIWKH+,3-2,17$;/Âą0HQX
1 Make sure to position the region of interest within the slanted-line area shown below.
Do not collimate further inside.
2 Positioning should be done so that the condyle and the femur run along the longer edge. (Do not
position them against the shorter edge.)
Condyle side
7/12
Femur side
1/12
1/4
Z-2
FDR D-EVO II Operation Manual
897N120339A
1/4
= ('5,PDJH'DWD$QDO\VLV
1 Image unevenness due to grid misalignment, X-ray beam misalignment, or shadow of clothes may
cause EDR image data analysis problems resulting in unstable density on the image.
2 If the target includes such materials as gypsum, denture, etc., stable density may not be obtained,
EHFDXVHVXFKPDWHULDOVPDNHLWGLIÂżFXOWWRDQDO\]H('5LPDJHGDWD
In such cases, use FIX MODE.
3 The EDR performs processing for the image area trimmed by the DR system.
:KHQXVLQJOHDGFKDUDFWHUVRUPHWDOVIRUPHDVXUHPHQWSODFHWKHPLQVLGHWKHUDGLDWLRQÂżHOGDQG
then make an exposure.
4 Precautions when using AUTO MODE.
Auto mode
Precautions
As this mode is available for extracting information on the skin, secure the positioning so
that the direct X-rays are incident to an area other than the target.
II
No special precautions.
III
Be sure to use a Ba contrast medium.
IV
1 Be sure to secure the positioning so that the X-rays are incident to the area directly
outside the target.
$VWKHUHDGLQJODWLWXGHLVÂż[HGLWLVQHFHVVDU\WRFRQWUROWKHWXEHYROWDJHDFFRUGLQJWRWKH
thickness of the target, as usual.
$VWKHUHDGLQJODWLWXGHLVÂż[HGLWLVQHFHVVDU\WRFRQWUROWKHWXEHYROWDJHDFFRUGLQJWRWKH
thickness of the target, as usual.
VI
No special precautions.
VII
No special precautions.
Appendix Z Precautions for Exposure
FDR D-EVO II Operation Manual
897N120339A
Z-3
Z.2 Precautions for Exposure in SEMIAUTO MODE
These precautions are common to Semi I, II, III and III(**).
1 Position the portion you need to display often in the center areas (10cm × 10cm(3.9 in. × 3.9 in.)
(Semi I), 7cm × 7cm(2.8 in. × 2.8 in.) (Semi II), 5cm × 5cm(2.0 in. × 2.0 in.) (Semi III)) of the images
trimmed by the DR system.
Position the portion you need to display often in each of the 5cm × 5cm(2.0 in. × 2.0 in.) center
areas of the half-split images (both upper and lower halves and right and left halves) and quartersplit image trimmed by the DR system.
2 Never position anything other than the subject in the aforementioned areas. If anything other than
the subject is positioned in such areas, the image density will become lower.
 ,QDGGLWLRQGRQRWSRVLWLRQDQ\PHWDOVRUDUWLÂżFLDOERQHVLQVXFKDUHDV7KHLPDJHGHQVLW\ZLOO
become higher if such objects are positioned in these areas.
3 It is necessary to control tube voltage according to subject thickness, as usual.
The following precautions should be observed for Semi IV.
Appendix Z Precautions for Exposure
Area
Center Coordinate
(x:y) cm(in.)
Size (cm(in.))
(0(0), 0(0))
10 × 10(3.9 × 3.9)
(-5(-2.0), 7(2.8))
6 × 6(2.4 × 2.4)
(5(2.0), 7(2.8))
6 × 6(2.4 × 2.4)
(-5(-2.0), -7(-2.8))
6 × 6(2.4 × 2.4)
(5(2.0), -7(-2.8))
6 × 6(2.4 × 2.4)
 'RQRWSRVLWLRQWUDQVSDUHQWSRUWLRQV DUHDVRWKHUWKDQWKHVXEMHFW LQWKHDIRUHPHQWLRQHGÂżYH
areas.
(2) It is necessary to control tube voltage according to subject thickness, as usual.
For details of the menus preset in SEMI-AUTO MODE, see the “DR-ID 300CL Operation Manual”
and “DR-ID 300CL Reference Guide (Image Processing Parameters)”.
Z-4
FDR D-EVO II Operation Manual
897N120339A
= 3UHFDXWLRQVIRU([SRVXUHLQ6(0,;
MODE
The user will select one of the nine areas of the image trimmed by the DR system, on which SEMIAUTO MODE applies. (See the illustration below.)
The same precautions as for SEMI-AUTO MODE apply.
5cm × 5cm
(2.0 in. × 2.0 in.)
Appendix Z Precautions for Exposure
FDR D-EVO II Operation Manual
897N120339A
Z-5
= 3UHFDXWLRQVIRU([SRVXUHLQ),;02'(
$VUHDGLQJFRQGLWLRQVDUHÂż[HGH[SRVXUHFRQGLWLRQVPXVWEHFRQWUROOHGLQWKHVDPHZD\DVIRU
conventional X-ray exposure.
The reading conditions (sensitivity and latitude) have been preset according to the relevant menu in
FIX MODE. Select the exposure conditions which correspond to that menu accordingly.
Appendix Z Precautions for Exposure
Z-6
FDR D-EVO II Operation Manual
897N120339A
= 3UHFDXWLRQVIRUWKH$XWRPDWLF;UD\
Detection Function
= 3UHFDXWLRQVIRU0DNLQJDQ([SRVXUH
1 7KHÀDWSDQHOVHQVRUFDQQRWGHWHFW;UD\VDXWRPDWLFDOO\XQOHVV6KRW5HDG\ H[SRVXUHUHDG\VWDWXV
LQGLFDWRU RQWKHLPDJHSURFHVVLQJXQLWWKH5($'<ODPSDPRQJWKHVWDWXVODPSVRQWKHÀDWSDQHO
sensor, or the READY lamp on the docking stand is lit green. Even if the indicator is not lit green,
radiation can be delivered but an image will not be output. Make sure that the indicator is lit green
before making an exposure.
2 Check the tube current of the X-ray equipment in advance, and set exposure conditions based
on the tube current by referring to the table below. If the conditions are not met, X-rays cannot be
detected automatically and an image may not be acquired.
Tube current
Tube voltage
Exposure
time
SID
5DGLDWLRQÂżHOG
More than
40 mA
Set the tube voltage
according to the
anatomical region
and body thickness.
More than
1 ms
(*3)
Set the SID according to
the anatomical region.
Do not limit the radiation
ÂżHOGWRWKHERQHUHJLRQ
(*1) only.
More than
20 mA and less
than 40 mA
Set the tube voltage
to more than 50 kV
according to the
anatomical region
and body thickness.
More than
10 mA and less
than 20 mA
Less than
10 mA
Set the SID to 100 cm (39.4 in.) or less and do not
OLPLWWKHUDGLDWLRQÂżHOGWRWKHERQHUHJLRQ  RQO\
Alternatively, set the SID according to the anatomical
region and include the directly exposed area (*2).
100 cm (39.4 in.) or less
Include the directly
exposed area (*2).
The automatic X-ray detection function cannot be used.
Appendix Z Precautions for Exposure
:KHQPDNLQJDQH[SRVXUHIRUH[DPSOHIRUDÂżQJHURUNQHHVHWWKHUDGLDWLRQÂżHOGWRDWOHDVWFPĂŽFP
LQĂŽLQ IRUWKHIRUPHUDQGDWOHDVWFPĂŽFP LQĂŽLQ IRUWKHODWWHUVRWKDWWKHÂżHOGLV
not limited to the bone region only.
7KHDUHDVRIWKHÀDWSDQHOVHQVRUZKLFKDUHGLUHFWO\H[SRVHGWR;UD\VWKDWGRQRWSDVVWKURXJKWKH
subject, must have a width of more than 3 cm (1.2 in.) from the subject.
*3 Depending on the X-ray equipment, the actual exposure time may differ from the set time. Before use,
PDNHVXUHWKDWWKHÀDWSDQHOVHQVRUFDQGHWHFW;UD\VDXWRPDWLFDOO\
3 As illustrated below, if the subject whose thinnest part is at least 40 cm (15.7 in.) in thickness
FRYHUVWKHHQWLUHVXUIDFHRIWKHÀDWSDQHOVHQVRULWFDQQRWGHWHFW;UD\VDXWRPDWLFDOO\DQGDQ
image may not be acquired. In this case, make an exposure for the region including the directly
exposed area or switch to the High Sensitivity Mode. While the high sensitivity mode is being set,
a shock might cause a blank image.
Figure of an exposure for the subject covering the entire surface of the flat panel sensor
FDR D-EVO II Operation Manual
897N120339A
Z-7
4 :KHQDQH[SRVXUHPHQXLVUHJLVWHUHGDQGWKHV\VWHPLVUHDG\IRUDQH[SRVXUHWKHÀDWSDQHO
sensor enters X-ray detection mode. If an exposure is not made for a period of time while an
H[SRVXUHPHQXLVUHJLVWHUHGWKHRSHUDWLQJWLPHRIWKHÀDWSDQHOVHQVRU¶VEDWWHU\SDFNPD\EH
reduced to half. In addition, the battery pack cannot be charged with an exposure menu registered,
HYHQLIWKHÀDWSDQHOVHQVRUKDVDZLUHGFRQQHFWLRQ)RUWKHVHUHDVRQVGRQRWNHHSWKHV\VWHPRQ
standby, unless you make an exposure.
= 3UHFDXWLRQV5HODWHGWRWKH;UD\([SRVXUH7LPH
:KHQGHOLYHULQJUDGLDWLRQGRQRWVHWWKHH[SRVXUHWLPHEH\RQGWKHPD[LPXPOLPLWVSHFLÂżHGIRUWKH
ÀDWSDQHOVHQVRUDWWKHWLPHRILQVWDOODWLRQ2WKHUZLVHYHUWLFDODUWLIDFWVPD\DSSHDULQWKHLPDJH
Appendix Z Precautions for Exposure
Z-8
FDR D-EVO II Operation Manual
897N120339A
Z.6 Precautions for Use in Wireless
Communication Mode
Care should be taken when the devices are used in wireless communication mode. Thoroughly read
the following precautions in order to use the devices properly.
Ĺś,FRQV'LVSOD\HGRQWKH,PDJH3URFHVVLQJ8QLW
An icon indicating the status of wireless communication is displayed in the connected devices status
at the lower right of the image processing unit display. Before an exposure is made, check the
displayed icon to make sure that proper wireless communication is established.
([SRVXUHXQLWGLVSOD\ÂżHOG
* The following display order is an example.
(1)
(2)
Connected devices status
(1) Exposure unit communication indicator
7KHZLUHOHVVFRPPXQLFDWLRQVWDWXVRIWKHÀDWSDQHOVHQVRUDVVLJQHGWRWKHVHOHFWRULVGLVSOD\HG
(2) Hospital wireless communication indicator
Appendix Z Precautions for Exposure
Displays the status of wireless communication between the image processing unit and the inhospital LAN.
Details on the icons regarding wireless communication displayed in the areas (1) and (2) are as follows.
Icon
Description
Display Area
Communication is established. The radio wave strength is displayed
in four levels. While is displayed, wireless communication or
image transfer to the hospital LAN becomes unstable.
(1) and (2)
([SRVXUHLVQRWDYDLODEOH &RPPXQLFDWLRQZLWKWKHÀDWSDQHO
sensor is disconnected.)
(1)
Wireless communication is not available. (Since the radio wave
strength is weak, wireless communication cannot be used. If this
icon is displayed in the area (1), exposures cannot be made.)
(1) and (2)
Information on the radio wave strength is being received.
(1)
The in-hospital LAN connection is being switched.
(2)
For details on other icons, see the “Console Advance (DR-ID 300CL) Reference Guide”.
FDR D-EVO II Operation Manual
897N120339A
Z-9
Z.7 Other Precautions
Z.7.1 Precautions for Exposure of a Subject in Relatively
/DUJH&RQWUDVW
1 Exposures using a contrast medium may cause artifacts around it.
2 When exposing a subject with any metal objects implanted, artifacts may appear around them.
3 For exposures with objects of large X-ray absorption, such as lead characters and metals for
measurement, artifacts may appear around them. Place such objects outside a subject.
Z.7.2 Precautions for Flat Panel Sensor
*HQHUDOO\ZKHQSHUIRUPLQJDKLJKVHQVLWLYLW\H[SRVXUHVKRUWO\DIWHUDQH[SRVXUHWKDWWKHÀDW
panel sensor excessively receives direct X-ray, the output image may contain image lags of the
previous exposure. This phenomenon rarely occurs and does not occur insofar as normal sensitivity
exposures are performed.
Exposures at longer intervals can reduce occurrences of this phenomenon. Also observe
precautions as follows.
• Continuous high sensitivity exposures to vertebral body part (chest/lumbar spine) should be
performed at longer intervals than normal exposures.
‡ $KLJKVHQVLWLYLW\H[SRVXUHVKRUWO\DIWHUDKLJKGRVHH[SRVXUHVKRXOGEHSHUIRUPHGDWVXI¿FLHQWO\
long interval.
‡ :KHQSHUIRUPLQJKLJKGRVHH[SRVXUHVUHSHDWHGO\GRQRWXVHFROOLPDWLRQRIWKHUDGLDWLRQ¿HOG
lead characters or metals for measurement at the same position.
= 3UHFDXWLRQVIRU$VVXULQJWKH5DGLDWLRQ)LHOG
Appendix Z Precautions for Exposure
CAUTIONS
Ɣ ,WLVLPSRUWDQWWRUHDGWKHIROORZLQJEHIRUHXVLQJWKH)'5'(92IIGLJLWDOGHWHFWRUFOLQLFDOO\
Ɣ 'RQRWPDNHWKHUDGLDWLRQ¿HOGODUJHUWKDQWKHVL]HRIWKHÀDWSDQHOVHQVRU(VSHFLDOO\ZKHQ
WKHKLJKWXEHYROWDJHLVVHWWKHUDGLDWLRQÂżHOGVL]HVKRXOGQRWEHODUJHUWKDQWKHVXEMHFW
unless necessary.
The FDR D-EVO II is a digital X-ray detector designed for use both within and outside of a standard
UDGLRJUDSKLFEXFN\5DGLDWLRQ¿HOGFDQEHVHWXSWR´î´ '5,'6('5,'6( RUXS
to 17” × 17” (DR-ID 1202SE/DR-ID1212SE) and this product may be used with the X-ray equipment
LQDQ\VLWXDWLRQZKHUHDÂżOPFDVVHWWHPD\EHXVHG
The collimator will open up to 14”× 17” for DR-ID 1201SE/DR-ID 1211SE and 17”× 17” for DR-ID
1202SE/DR-ID 1212SE, when the FDR D-EVO II cassette is inserted in the bucky tray of the X-ray
equipment with positive beam limitation (PBL).
)ROORZWKH;UD\V\VWHPPDQXIDFWXUHUÂśVLQVWUXFWLRQVWRDVVXUHWKHLQGLFDWHGÂżHOGVL]HPDWFKHVDQG
GRHVQRWH[FHHGWKHDFWXDOUDGLDWLRQÂżHOGVL]HIRUWKHDYDLODEOHUDQJHRI6,'V
= ,PDJHV2XWSXW:KHQWKH;UD\6KRW6ZLWFKLV2SHUDWHG
Incorrectly
In case that you press the X-ray shot switch only momentarily after selecting exposure menus,
VXIÂżFLHQW;UD\GRVHPD\QRWEHDFKLHYHG7KHRXWSXWLPDJHFRQWDLQVLPDJHODJVRIWKHSUHYLRXV
exposure occasionally.
If this happens, select exposure menus again, and then make an exposure.
Z-10
FDR D-EVO II Operation Manual
897N120339A
= 3UHFDXWLRQVIRU8UJHQW8VH
When you start a study before completion of the calibration at the time of startup, the operation will
be in Urgent Use Mode. At this time, “Urgent use is possible” appears in the “Output Device Status
window” of the image processing unit.
• There is no guarantee that the image taken in Urgent Use Mode can be used for diagnostic
purposes. Vertical artifact could appear in the image, if the temperature difference is large from
the previous shutdown of the system. Check the image quality before use.
• Move from the Study Screen to the Patient Information Input Screen immediately after exiting
Urgent Use Mode, so that the calibration will start over automatically.
Z.7.6 Precautions Related to Continuous Operation
If you plan to continuously run the system for over 24 hours, perform post-operation check, and
then restart the system.
Otherwise, calibration will not be performed normally, and image quality cannot be guaranteed as a
result.
Z.7.7 Precautions Related to Grid
Depending on the type of the grid used, its stripes may appear in the image after making an
exposure. To avoid such moire effects, sway the grid from side to side, or use the Grid Pattern
Removal Processing Software in conjunction with the grid with 40 lines.
= 3UHFDXWLRQVGXULQJ&DOLEUDWLRQ
2EVHUYHWKHIROORZLQJZKHQWKH5($'<VWDWXVODPSRQWKHÀDWSDQHOVHQVRULVEOLQNLQJRUZKHQWKH
message “Calibrating...” is displayed on the image processing unit.
Appendix Z Precautions for Exposure
‡ 'RQRWVXEMHFWWKHÀDWSDQHOVHQVRUWRVKRFN
• Do not deliver radiation.
‡ 'RQRWFRQQHFWGLVFRQQHFWWKHÀDWSDQHOVHQVRUWRIURPWKHSRZHUVXSSO\XQLWRUWRIURPWKH
docking stand.
= 3UHFDXWLRQVIRU([SRVLQJWKH)ODW3DQHO6HQVRUWR;UD\
:KHQ\RXH[SRVHWKHÀDWSDQHOVHQVRUWR;UD\DWDQ\RWKHUWLPHH[FHSWGXULQJUDGLRJUDSK\
artifacts could appear in the image. If artifacts appeared in the image due to X-ray irradiation,
perform a test X-ray radiography after waiting for more than 2 minutes and then restart exposure
DIWHUFRQÂżUPLQJWKDWWKHDUWLIDFWVGLVDSSHDU
=3UHFDXWLRQVIRU([WHQGHG,PDJH5HDGRXW
,IDQ\LPSDFWLVDSSOLHGWRWKHÀDWSDQHOVHQVRUZKLOHDQLPDJHLVEHLQJDFTXLUHGZLWK([WHQGHG
,PDJH5HDGRXWDUWLIDFWVPD\DSSHDULQWKHLPDJH%HIRUHUHPRYLQJWKHÀDWSDQHOVHQVRUIURPWKH
radiographic examination stand, be sure to check the acquired image on the image processing unit.
In addition, note that when Extended Image Readout is enabled, the system cannot be used in an
emergency since the system start-up time becomes longer.
FDR D-EVO II Operation Manual
897N120339A
Z-11
=3UHFDXWLRQVIRU8VLQJWKH$FFHVV3RLQW
When making an exposure with the access point, do not remove the USB cable until the image
appears on the image processing unit and ShotReady lights green.
Also, with the supplied Velcro tape and clamp or by other means, secure the USB cable before use
to prevent it from being disconnected accidentally.
Appendix Z Precautions for Exposure
Z-12
FDR D-EVO II Operation Manual
897N120339A
Appendix O
Use of Optional Items
O.1 Optional Items
Name
SE storage case
Description
$FDVHXVHGIRUFDUU\LQJDQGVWRULQJWKHÀDWSDQHOVHQVRU
For the external view and precautions, see “O.2 Using the SE Storage
Case” (page O-2).
Battery pack
$EDWWHU\SDFNIRUWKHÀDWSDQHOVHQVRU
For precautions, charging and installing/removing, see pages 1-8, 1-9, 3-6,
3-7 and 3-8.
Battery charger
A battery charger for the battery pack.
For precautions, external view and charging, see pages 1-8, 1-9, 2-5, 3-6
and 3-7.
Retaining bracket for MP
$VHWRIDQDQFKRUDQGDÂż[WXUHZKLFKLVXVHGIRUVHFXULQJWKHSRZHUVXSSO\
XQLWWRWKHÀRRU
For the external view, see “O.3 Using the Retaining bracket for MP” (page
O-3).
SE cable
$FDEOHWKDWFRQQHFWVWKHÀDWSDQHOVHQVRUDQGWKHSRZHUVXSSO\XQLW
7KLVFDEOHLVXVHGIRUDGGLQJWKHVHFRQGDQGVXEVHTXHQWÀDWSDQHO
VHQVRUVFKDQJLQJRYHUWKHFRQQHFWLRQEHWZHHQWKHÀDWSDQHOVHQVRUVDQG
other usages.
Relay unit for AC bucky
A relay unit consisting of the relay and terminal block for the AC bucky.
)RXUW\SHVDUHDYDLODEOH)RU999DQG9
0DJQHWLFFODPSIRUÀDWSDQHO
sensor cable
$FODPSIRUÂż[LQJWKH6(FDEOHWRWKHUDGLRJUDSKLFH[DPLQDWLRQVWDQGHWF
Adapter for the docking stand
$QDGDSWHUXVHGIRUDWWDFKLQJWKHÀDWSDQHOVHQVRUWRWKHGRFNLQJVWDQG
DS Anchor Fixing Bracket
$QDQFKRUDQG¿[LQJWRROVHWXVHGIRU¿[LQJWKHGRFNLQJVWDQGWRWKHÀRRU
Appendix O Use of Optional Items
For the external view, see “O.4 DS Anchor Fixing Bracket” (page O-4).
Wall Fixing Bracket
$QDQFKRUDQG¿[LQJWRROVHWXVHGIRU¿[LQJWKHGRFNLQJVWDQGWRWKHÀRRU
For the external view, see “O.5 Wall Fixing Bracket” (page O-5).
SE communication cable
$FDEOHXVHGIRUFRQQHFWLQJWKHÀDWSDQHOVHQVRUDQGWKHRSWLRQDODFFHVVSRLQW
This cable is used for wired communication if wireless communication is not
available.
,QDGGLWLRQWKLVFDEOHLVXVHGIRUUHJLVWHULQJRUUHFRJQL]LQJWKHÀDWSDQHOVHQVRU
&DEOHOHQJWK$SSUR[P IW
Access point
$QDFFHVVSRLQWXVHGIRUZLUHOHVVFRPPXQLFDWLRQEHWZHHQWKHÀDWSDQHOVHQVRU
and the image processing unit.
FDR D-EVO II Operation Manual
897N120339A
O-1
28VLQJWKH6(6WRUDJH&DVH
SE storage case for 35
(DR-ID 1201SE/DR-ID 1211SE)
SE storage case for 43
(DR-ID 1202SE/DR-ID 1212SE)
CAUTIONS
Ɣ 'RQRWVWRUHWKH6(VWRUDJHFDVHLQDORFDWLRQZLWKWKHIROORZLQJFRQGLWLRQV
 Ɣ:KHUHWKH6(VWRUDJHFDVHLVH[SRVHGWRGLUHFWVXQOLJKW
 Ɣ:KHUHWKHWHPSHUDWXUHDQGKXPLGLW\FKDQJHGUDPDWLFDOO\
 Ɣ:KHUHWKHUHLVH[FHVVLYHGXVW
 Ɣ:KHUHFKHPLFDOVDUHVWRUHG
 Ɣ:KHUHWKH6(VWRUDJHFDVHPD\EHH[SRVHGWRZDWHUGXHWRZDWHUOHDNDJHRULQJUHVV
Ɣ 6WRUHWKHÀDWSDQHOVHQVRUDQGWKHFDEOHSURSHUO\LQWKH6(VWRUDJHFDVH
 2WKHUZLVHWKH\PD\EHFDXJKWXQGHUWKHFDVHOLGDQGGDPDJHG
Ɣ 'RQRWFRQQHFWWKHÀDWSDQHOVHQVRUWRWKH6(FDEOHRU6(FRPPXQLFDWLRQFDEOHZKLOHLWLV
VWRUHGLQWKH6(VWRUDJHFDVH
Ɣ 'RQRWVWRUHDQ\WKLQJRWKHUWKDQWKHÀDWSDQHOVHQVRULQWKH6(VWRUDJHFDVH
Ɣ &DUHIXOO\FDUU\WKH6(VWRUDJHFDVHZKHQWKHÀDWSDQHOVHQVRULVLQVLGH
Ɣ 7
 KH6(VWRUDJHFDVHDQGRUWKHÀDWSDQHOVHQVRULQVLGHPD\EHGDPDJHGLIWKHFDVHLV
subject to an impact.
Ɣ 'RQRWRSHQFORVHWKH6(VWRUDJHFDVHLQDORFDWLRQZKHUHWKHUHLVH[FHVVLYHGXVWRUGLUW
Ɣ 'RQRWSXWWKH6(VWRUDJHFDVHRQDQXQVWDEOHSODFH,ILWIDOOVRUGURSVSHUVRQDOLQMXU\PD\UHVXOW
Ɣ %HFDUHIXOQRWWRKDYH\RXUKDQGRUDQREMHFWFDXJKWZKHQFORVLQJWKH6(VWRUDJHFDVH
Appendix O Use of Optional Items
:KHQVWRULQJWKHÀDWSDQHOVHQVRULQWKH6(VWRUDJHFDVHSODFHLWZLWKWKHH[SRVXUHSODQHGRZQ
For details, see the illustrations below.
Battery holder
pockets
SE storage case for 35
(DR-ID 1201SE/DR-ID 1211SE)
O-2
FDR D-EVO II Operation Manual
897N120339A
Battery holder
pockets
SE storage case for 43
(DR-ID 1202SE/DR-ID 1212SE)
28VLQJWKH5HWDLQLQJ%UDFNHWIRU03
&RQWDFWD)8-,),/0GHDOHUIRULQVWDOODWLRQRIWKH5HWDLQLQJEUDFNHWIRU03
Appendix O Use of Optional Items
FDR D-EVO II Operation Manual
897N120339A
O-3
2'6$QFKRU)L[LQJ%UDFNHW
&RQWDFWD)8-,),/0GHDOHUIRULQVWDOODWLRQRIWKH'6DQFKRUÂż[LQJEUDFNHW
Appendix O Use of Optional Items
O-4
FDR D-EVO II Operation Manual
897N120339A
2:DOO)L[LQJ%UDFNHW
&RQWDFWD)8-,),/0GHDOHUIRULQVWDOODWLRQRIWKHZDOOÂż[LQJEUDFNHW
Appendix O Use of Optional Items
FDR D-EVO II Operation Manual
897N120339A
O-5
O.6 Access Point
Precautions for Use
CAUTIONS
Appendix O Use of Optional Items
Ɣ7KH$FFHVV3RLQWLQFRUSRUDWHVDZLUHOHVVGHYLFHWKDWFRPSOLHVZLWKWKHWHFKQLFDOVWDQGDUGV
Do not disassemble or modify the Access Point.
In addition, do not remove the name plate attached to this product. If the name plate is not
attached, use of this product is prohibited.
Ɣ8VHRIWKH$FFHVV3RLQWLVDOORZHGLQWKHDUHDRISXUFKDVH
Ɣ0DNHVXUHWKDWWKHUHDUHQRVKLHOGLQJPDWHULDOVEHWZHHQWKH$FFHVV3RLQWDQGWKHFRPPXQLFDWLRQ
device. For example, if there is a metal plate or concrete wall between them, wireless
communication may not be available. In addition, do not cover the plane with the status lamps.
Ɣ'RQRWXVHWKH$FFHVV3RLQWQHDUWKHIROORZLQJGHYLFHV
 ,QGXVWULDOVFLHQWLÂżFDQGPHGLFDOHTXLSPHQWVXFKDVDPLFURZDYHRYHQSDFHPDNHUHWF
- /RFDOSULYDWHUDGLRVWDWLRQVIRUPRELOHREMHFWLGHQWLÂżFDWLRQXVHGLQIDFWRU\SURGXFWLRQOLQHVHWF
UDGLRVWDWLRQVUHTXLULQJDOLFHQVH
 6SHFLÂżHGORZSRZHUUDGLRVWDWLRQV UDGLRVWDWLRQVUHTXLULQJQROLFHQVH
Ɣ'RQRWXVHWKH$FFHVV3RLQWQHDUUDGLRVWHOHYLVLRQVPRELOHSKRQHVRU3+6SKRQHVDVIDUDV
possible. If these devices are placed near the wireless LAN products, audio or video noise may
RFFXUGXHWRHOHFWURPDJQHWLFZDYHVJHQHUDWHGIURPWKHZLUHOHVV/$1SURGXFWVLQFOXGLQJWKH
Access Point.
Ɣ'RQRWXVHWKH$FFHVV3RLQWQHDUDKHDWVRXUFH,QDGGLWLRQGRQRWFRYHUWKHYHQWLODWLRQKROHV
Ɣ'RQRWDOORZWKH$FFHVV3RLQWJHWZHWRUGXVW\
Ɣ7DNHFDUHQRWWRWULSRYHUWKHFDEOH,IWKHFDEOHLVGLVFRQQHFWHGRUDOPRVWGLVFRQQHFWHG
wireless communication may not be established.
Ɣ'RQRWVXEMHFWWKH$FFHVV3RLQWWRVHYHUHVKRFN E\GURSSLQJLWHWF 
Ɣ:KHQXVLQJWKH$FFHVV3RLQWSODFHLWDWOHDVWFP LQ DZD\IURPWKHERG\
Ɣ7RVXSSO\SRZHUWRWKH$FFHVV3RLQWFRQQHFWLWWRWKH)8-,),/0VSHFL¿HGSHUVRQDOFRPSXWHU
VXSSRUWLQJ86%
Ɣ8VHWKH$FFHVV3RLQWE\FRQQHFWLQJLWWRWKHSUHVHWLPDJHSURFHVVLQJXQLWDQGWRWKH86%
connector.
Ɣ'LUHFWO\FRQQHFWWKH$FFHVV3RLQWDQGWKHLPDJHSURFHVVLQJXQLWRQO\ZLWKWKHVXSSOLHG86%
cable. Do not use a hub for connection.
Ɣ'RQRWGHOHWHRUFKDQJHWKH86%GULYHULQVWDOOHGLQWKHLPDJHSURFHVVLQJXQLW
Ɣ'RQRWSODFHWKHVXSSOLHG9HOFURWDSHRYHUWKH$FFHVV3RLQW3URGXFW/DEHODQG$FFHVV3RLQW
5DGLR/DZ&HUWLÂżFDWLRQ/DEHO
O-6
O II Operation Manual
897N120339A
Precautions for LAN Connection
CAUTIONS
Ɣ)RUWKH/$1FRQQHFWLRQXVHWKHGHGLFDWHG/$1FRQYHUVLRQFDEOH,QDGGLWLRQZKHQFRQQHFWLQJ
RUGLVFRQQHFWLQJWKH/$1FRQYHUVLRQFDEOHEHVXUHWRKROGWKHFRQQHFWRUSRUWLRQ
,ILWLVFRQQHFWHGRUGLVFRQQHFWHGZKLOHKROGLQJWKHFDEOHWKHFDEOHPD\EHEURNHQ
Ɣ5DGLRZDYHVDYDLODEOHRXWGRRUVYDU\GHSHQGLQJRQWKHFRXQWU\ZKHUHWKHV\VWHPLVXVHG
(For U.S.)
 5DGLRZDYHVLQWKH*+]IUHTXHQF\EDQGFDQEHXVHGLQGRRUVRQO\
 :
 KHQUDGLRZDYHVLQWKH*+]DQG*+]IUHTXHQF\EDQGVDUHVHOHFWHGWKH')6IXQFWLRQZLOO
operate.
Ɣ:KHQWKH$FFHVV3RLQWDQGDSHUVRQDOFRPSXWHULVFRQQHFWHGXVLQJWKH86%FDEOHGRQRW
connect the Access Point and the personal computer via the LAN connection.
3UHFDXWLRQVIRU8VLQJWKH')6 '\QDPLF)UHTXHQF\6HOHFWLRQ )XQFWLRQ
CAUTIONS
Ɣ7KH$FFHVV3RLQWVXSSRUWVWKH')6IXQFWLRQFRQIRUPLQJWR,(((Q,IDUDGDUZDYHLV
GHWHFWHGZKLOHVHWWLQJDFKDQQHOWKHFKDQQHOPD\EHFKDQJHGDXWRPDWLFDOO\LQRUGHUWRDYRLG
interference to weather radar, etc.
Ɣ'XULQJVWDUWXSWKH$FFHVV3RLQWFKHFNVLIWKHUHDUHDQ\UDGDUZDYHV:KLOHWKHFKHFNLVLQ
SURJUHVVFRPPXQLFDWLRQZLWKWKH$FFHVV3RLQWLVQRWDYDLODEOH
Ɣ,IDUDGDUZDYHLVGHWHFWHGWKHUDGDUZDYHLVPRQLWRUHGIRUDVSHFL¿HGWLPH DERXWPLQXWH 
:KLOHPRQLWRULQJWKHUDGDUZDYHZLUHOHVVFRPPXQLFDWLRQLVQRWDYDLODEOH,QDGGLWLRQDERXW
PLQXWHVDUHUHTXLUHGXQWLOWKHFKDQQHOLQZKLFKDUDGDUZDYHZDVGHWHFWHGEHFRPHVDYDLODEOH
For details of the access point, see “Access point Operation Manual”.
Appendix O Use of Optional Items
FDR D-EVO II Operation Manual
897N120339A
O-7
Appendix O Use of Optional Items
O-8
O II Operation Manual
897N120339A
Maintenance and Inspection
 0DLQWHQDQFHDQG,QVSHFWLRQ,WHPV$VVLJQHGWR6SHFLÂżHG'HDOHU
)RUSHULRGLFDOLQVSHFWLRQRIWKHHTXLSPHQWDQGQHFHVVDU\DUUDQJHPHQWVFRQVXOWRXURIÂżFLDOGHDOHU
or local representative.
Periodical Maintenance
0DNHVXUHWKDWWKHSHULRGLFDOPDLQWHQDQFHDQGLQVSHFWLRQDVVLJQHGWRRXURIÂżFLDOGHDOHURU
)8-,),/05HSUHVHQWDWLYHDUHSHUIRUPHGDVVSHFLÂżHG
0DLQWHQDQFHDQG,QVSHFWLRQ,WHPV$VVLJQHGWR6SHFLÂżHG'HDOHU
Periodical Maintenance and Inspection Items
Period
Checking of the image
Every year
Checking of the operation record by referring to the error log
Every year
Checking of the units
Every 2 years
Main Periodical Replacement Parts
Name of Periodical Replacement Parts
Relay (optional)
Period
Every 1 year
1XPEHURIH[SRVXUHV
* It is recommended that the battery pack be replaced, if the battery storage capacity becomes
lower than 60%.
The battery pack should be replaced when the operable time is less than the following.
 Ɣ'5,'6('5,'6('5,'6('5,'6(PLQXWHV KRXUDQGPLQXWHV
* Refer to the operable time displayed on the image processing unit when the battery pack is fully
charged and no exposure menu is registered.
* Depending on the usage environment, etc., the displayed time is slightly different from the
actual operable time.
(Reference) Time for battery pack replacement
120
Battery storage capacity [%]
100
80
60
40
Time for replacement:
Less than 100 minutes
(1 hour and 40 minutes)
20
30
60
90
120
150
180
210
240
Operable time [Minute]
The cycles of periodical maintenance and inspection and of parts replacement differ depending on
the usage and the daily operation time.
)RUGHWDLOVFRQWDFWRXURIÂżFLDOGHDOHURU)8-,),/05HSUHVHQWDWLYH
FDR D-EVO II Operation Manual
897N120339A
Maintenance and Inspection
Maintenance and Inspection
FDR D-EVO II Operation Manual
897N120339A
5DGLRIUHTXHQF\ 5) FRPSOLDQFHLQIRUPDWLRQ
&RPSOLDQFHZLWK(&
0DQXIDFWXUHUÂśV1DPH 
0DQXIDFWXUHUÂśV$GGUHVV
)8-,),/0&RUSRUDWLRQ
1LVKLD]DEX&KRPH0LQDWR.X7RN\R-$3$1
GHFODUHVWKDWWKHSURGXFW
3URGXFW1DPH
3$1(/81,7
0RGHO1XPEHU
'5,'38
(DR-ID 1200MP, DR-ID 1201SE, DR-ID 1202SE, DR-ID 1211SE and DR-ID 1212SE)
DR-ID 1200DU
(DR-ID 1200DS, DR-ID 1201SE, DR-ID 1202SE, DR-ID 1211SE and DR-ID 1212SE)
7KHSURGXFWFRPSOLHVZLWKWKHUHTXLUHPHQWVRIWKH5 77('LUHFWLYH(&
The formal “Declaration of Conformity” can be obtained in the following-mentioned address.
$GGUHVV0L\DQRGDL.DLVHLPDFKL$VKLJDUDNDPLJXQ.DQDJDZD-$3$1
The shipment schedule country is as follows.
AT
BE
BG
CH
CY
CZ
DE
DK
EE
ES
FI
FR
GB
GR
HR
HU
IE
IS
IT
LI
LT
LU
LV
MK
MT
NL
NO
PL
PT
RO
SE
SI
SK
TR
[BG]
Bulgarian
[CS]
ɋɧɚɫɬɨɹɳɟɬɨ)8-,),/0ɞɟɤɥɚɪɢɪɚɱɟ'5,'38'5,''8
ɟɜɫɴɨɬɜɟɬɫɬɜɢɟɫɴɫɫɴɳɟɫɬɜɟɧɢɬɟɢɡɢɫɤɜɚɧɢɹɢɞɪɭɝɢɬɟɩɪɢɥɨɠɢɦɢ
ɪɚɡɩɨɪɟɞɛɢɧɚȾɢɪɟɤɬɢɜɚ(&
)8-,),/0WtPWRSURKODãXMHåH'5,'38'5,''8VSOĖXMH
]iNODGQtSRåDGDYN\DYãHFKQDSĜtVOXãQiXVWDQRYHQL6PČUQLFH(6
Czech
[DA]
Danish
[DE]
German
[EN]
English
[ES]
Spanish
Undertegnede FUJIFILM erklÌrer herved, at følgende udstyr DR-ID 1200PU,
DR-ID 1200DU overholder de vÌsentlige krav og øvrige relevante krav i
direktiv 1999/5/EF.
Hiermit erklärt FUJIFILM, dass sich das Gerät DR-ID 1200PU, DR-ID 1200DU
in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen
HLQVFKOlJLJHQ%HVWLPPXQJHQGHU5LFKWOLQLH(*EHÂżQGHW
Hereby, FUJIFILM, declares that this DR-ID 1200PU, DR-ID 1200DU is in
compliance with the essential requirements and other relevant provisions of
Directive 1999/5/EC.
Por la presente, FUJIFILM, declara que este DR-ID 1200PU, DR-ID 1200DU
cumple con los requisitos esenciales y otras exigencias relevantes de la
Directiva 1999/5/EC.
FDR D-EVO II Operation Manual
897N120339A
[ET]
Estonian
[FI]
Finish
[FR]
French
[EL]
Greek
[HU]
Hungarian
[HR]
Croatian
[IS]
Icelandic
[IT]
Italian
[LV]
Latvian
[LT]
Käesolevaga kinnitab FUJIFILM seadme DR-ID 1200PU, DR-ID 1200DU
vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist
tulenevatele teistele asjakohastele sätetele.
FUJIFILM vakuuttaa täten että DR-ID 1200PU, DR-ID 1200DU tyyppinen
laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien
direktiivin muiden ehtojen mukainen.
Par la présente, FUJIFILM déclare que l’appareil DR-ID 1200PU, DR-ID 1200DU
est conforme aux exigences essentielles et aux autres dispositions pertinentes de
la directive 1999/5/CE.
ȂǼȉǾȃȆǹȇȅȊȈǹȅȀǹȉǹȈȀǼȊǹȈȉǾȈ)8-,),/0ǻǾȁȍȃǼǿȅȉǿ
'5,'38'5,''8ȈȊȂȂȅȇĭȍȃǼȉǹǿȆȇȅȈȉǿȈȅȊȈǿȍǻǼǿȈ
ǹȆǹǿȉǾȈǼǿȈȀǹǿȉǿȈȁȅǿȆǼȈȈȋǼȉǿȀǼȈǻǿǹȉǹȄǼǿȈȉǾȈȅǻǾīǿǹȈ
ǼȀ
A FUJIFILM ezzennel kijelenti, hogy a DR-ID 1200PU, DR-ID 1200DU
WtSXV~EHUHQGH]pVWHOMHVtWLD]DODSYHWĘN|YHWHOPpQ\HNHWpVPiV(.
irĂĄnyelvben meghatĂĄrozott vonatkozĂł rendelkezĂŠseket.
2YLPH)8-,),/0SRWYUĂżXMHGDMH'5,'38'5,''8X
VXNODGQRVWVDRVQRYQLP]DKWMHYLPDLGUXJLPYDĂĽQLPRGUHGEDPD'LUHNWLYH
1999/5/EC.
+pUPHèOêVLU)8-,),/0\¿UÏYtDè'5,'38'5,''8HUt
VDPU PLYLèJUXQQNU|IXURJDèUDUNU|IXUVHPJHUèDUHUXtWLOVNLSXQ
EC
Con la presente FUJIFILM dichiara che questo DR-ID 1200PU, DR-ID 1200DU
è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite
dalla direttiva 1999/5/CE.
$UãR)8-,),/0GHNODUƝND'5,'38'5,''8DWELOVW
'LUHNWƯYDV(.EnjWLVNDMƗPSUDVƯEƗPXQFLWLHPDUWRVDLVWƯWDMLHP
noteikumiem.
Ĺ iuo FUJIFILM deklaruoja, kad ĹĄis DR-ID 1200PU, DR-ID 1200DU atitinka
esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas
Lithuanian
>ɆɄ@
Macedonian
[MT]
Maltese
[NL]
Dutch
[NO]
Norwegian
[PL]
Polish
[PT]
)8-,),/0ɢɡʁɚɜɭɜɚɞɟɤɚɨɜɨʁ'5,'38'5,''8ɟɜɨ
ɫɨɝɥɚɫɧɨɫɬɫɨɫɭɲɬɢɧɫɤɢɬɟɛɚɪɚʃɚɢɞɪɭɝɢɪɟɥɟɜɚɧɬɧɢɨɞɪɟɞɛɢɧɚ
Ⱦɢɪɟɤɬɢɜɚɬɚ(&
Hawnhekk, FUJIFILM, jiddikjara li dan DR-ID 1200PU, DR-ID 1200DU
MLNNRQIRUPDPDOĆŤWLĆĽLMLHWHVVHQ]MDOLXPDSURYYHGLPHQWLRĆŤUDMQUHOHYDQWLOL
KHPPÂżG'LUUHWWLYD(&
Hierbij verklaart FUJIFILM dat het toestel l DR-ID 1200PU, DR-ID 1200DU
in overeenstemming is met de essentiĂŤle eisen en de andere relevante
bepalin-gen van richtlijn 1999/5/EG.
FUJIFILM erklĂŚrer herved at utstyret DR-ID 1200PU, DR-ID 1200DU er
i samsvar med de grunnleggende krav og øvrige relevante krav i direktiv
1999/5/EF.
1LQLHMV]\P)8-,),/0GHNODUXMHÄŞH'5,'38'5,''8MHVW
]JRGQ\]]DVDGQLF]\PLZ\PDJDQLDPLLLQQ\PLZáDĞFLZ\PLSRVWDQRZLHQLDPL
Dyrektywy 1999/5/EC.
Eu, FUJIFILM, declaro que o DR-ID 1200PU, DR-ID 1200DU cumpre os
requisitos essenciais e outras provisĂľes relevantes da Directiva 1999/5/EC.
Portuguese
FDR D-EVO II Operation Manual
897N120339A
[RO]
Romanian
[SK]
3ULQSUH]HQWD)8-,),/0GHFODUăFăDSDUDWXO'5,'38'5,''8
HVWHvQFRQIRUPLWDWHFXFHULQÄ HOHHVHQÄ LDOHĂşLFXDOWHSUHYHGHULSHUWLQHQWHDOH
Directivei 1999/5/CE.
)8-,),/0WêPWRY\KODVXMHåH'5,'38'5,''8VSĎĖD
]iNODGQpSRĂĽLDGDYN\DYĂŁHWN\SUtVOXĂŁQpXVWDQRYHQLD6PHUQLFH(6
Slovak
[SL]
FUJIFILM izjavlja, da je ta DR-ID 1200PU, DR-ID 1200DU v skladu z
ELVWYHQLPL]DKWHYDPLLQGUXJLPLUHOHYDQWQLPLGRORĂžLOLGLUHNWLYH(6
Slovenian
[SV]
Swedish
[TR]
Turkish
Härmed intygar FUJIFILM, att denna DR-ID 1200PU, DR-ID 1200DU är
I|UHQOLJWPHGGHJUXQGOlJJDQGHNUDYHQRFKDQGUDUHOHYDQWDEHVWlPPHOVHUL
direktivet 1999/5/EG.
øúEXEHOJHLOH)8-,),/0EX'5,'38'5,''8UQQQ
(&VD\ÕOÕ<|QHUJH¶QLQWHPHOúDUWODUÕ\ODYHGL÷HULOJLOLKNPOHUL\OH
X\XPOXROGXáXQXEH\DQHGHU
FDR D-EVO II Operation Manual
897N120339A
FUJIFILM MEDICAL SYSTEMS U.S.A., INC.
:(67$9(18(67$0)25'&786$

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : 14539
Create Date                     : 2014:11:19 11:48:11+09:00
Modify Date                     : 2014:11:19 11:48:11+09:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Instance ID                     : uuid:0e6f0676-8382-476b-b746-e692e5af4a42
Original Document ID            : adobe:docid:indd:b00e80c8-89dd-11e1-8720-8420a54dfcb3
Document ID                     : xmp.id:476C7F181150E411A09A82C810678A03
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:466C7F181150E411A09A82C810678A03
Derived From Document ID        : adobe:docid:indd:b00e80c8-89dd-11e1-8720-8420a54dfcb3
Derived From Original Document ID: adobe:docid:indd:b00e80c8-89dd-11e1-8720-8420a54dfcb3
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2014:10:10 09:05:47+09:00
Metadata Date                   : 2014:10:15 14:12:44+09:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Format                          : application/pdf
Creator                         : 14539
Title                           : 897N120339A_Z72N3191A_141015.pdf
Producer                        : Acrobat Distiller 10.1.2 (Windows)
Trapped                         : False
Page Count                      : 130
EXIF Metadata provided by EXIF.tools
FCC ID Filing: W2Z-01000006

Navigation menu