Fujitsu Aou18Rlxfz Users Manual HFI_Multi_Brochure_1 2013_

2015-01-25

: Fujitsu Fujitsu-Aou18Rlxfz-Users-Manual-218164 fujitsu-aou18rlxfz-users-manual-218164 fujitsu pdf

Open the PDF directly: View PDF PDF.
Page Count: 8

DownloadFujitsu Fujitsu-Aou18Rlxfz-Users-Manual- HFI_Multi_Brochure_1-2013_  Fujitsu-aou18rlxfz-users-manual
Open PDF In BrowserView PDF
Hybrid Flex Inverter System
Dual, Tri and Quad Zone Mix & Match Flexibility
Includes RLS2 Designer Series Indoor Models

!
NEW

Mini-Split Air Conditioners and Heat Pumps
AOU18RLXFZ
AOU24RLXFZ
AOU36RLXFZ

Use mini-splits just about any place that requires comfort!
Older homes l New construction homes l Schools l Places of worship
Hospitals and medical facilities l Restaurants l Computer rooms
Hotels and motels l Car washes l Convenience stores
Fast food chains l Fire houses l Police stations l Oil rigs l Bars
Sunrooms and additions l Warehouses l Nursing homes
ATM vestibules l Small offices...

Hybrid Flex Inverter System
Zoned Mix and Match Flexibility

multi
18, 24, 36,000 BTUs

AOU18RLXFZ, AOU24RLXFZ, AOU36FLXFZ

Contractors can select either an 18, 24
or 36,000 BTU outdoor unit combined
with wall mounted, compact cassette or
compact duct type indoor units. Mix-andmatch flexibility of evaporator type and
capacity allows you to choose the indoor
unit that best fits the application, whether it
be hidden or showcased. These systems
are ideal for nursing homes, doctor's
offices, condominiums, apartments and
residences - any place where individual
cooling or heating is needed.

Features
l

Part of the Halcyon Hybrid Flex Inverter (HFI) Line
As part of the HFI line of components, indoor units
are compatible with other HFI outdoor units, meaning
mix and match capabilities with fewer components.

l

No Branch Boxes or Separation Tube Assemblies
While the 8-zone AOU48RLXFZ1 model requires both
branch boxes and separation tube assembly kits, the
smaller zoned units - AOU18, 24 and 36RLXFZ
do not require them.

l

Pricing Compared to Competition
Additional outdoor units provides better matched BTU 
capacity with indoor units. By better matching the
outdoor unit to the indoor capacity a better system value
is achieved.

l

High Efficiency Systems
Up to 18-SEER in efficiency, these units are 22%
more efficient than 14-SEER competing multi-zone
systems.

l

Why Choose an 18,000 BTU Zoned System?
A lower BTU dual zone is often the perfect solution to a
comfort need. A consumer shouldn’t have to purchase
a higher priced larger unit when only 14 to 18,000 BTU’s
are needed.

l

Connectable Capacity
Our 3 outdoor units provide systems from 14,000 to 39,000 BTU. Some connectable capacity is provided to allow
increased combinations and flexibility. All indoor units can operate at once, how ever if all the evaporators are
calling for cooling or heating at the same time it will decrease the capacity of each evaporator not to exceed the
condenser’s capacity. As zones meet desired set point the system’s other evaporators increase output up to the
evaporator’s rated capacity.

l

A Tri-Zone 24,000 BTU Unit
Fujitsu offers a 2-ton system that provides 2 or 3-zone
flexibility. By using connectable capacity, this system
allows up to three 9,000 BTU units.

For example: The load on a 3-bedroom home with a living room and kitchen downstairs and 3 bedrooms upstairs is
39,000 BTUs (21,000 BTU downstairs and 18,000 BTU upstairs). However the family isn’t upstairs and downstairs at
the same time, therefore not all units will be running simultaneously allowing 100% heating or cooling to occupied
spaces. This can be achieved by our AOU36RLFXZ outdoor unit.

2

!

RLS2 Designer Series Compatibility
Wall Mounted ASU9RLS2, ASU12RLS2, ASU15RLS2
Fujitsu’s indoor RLS2 models are now compatible with outdoor multizone units so contractors can choose between different wall mounted
styles as well as different evaporator styles (wall mounted, compact
cassette or compact duct).
Features:
l Sleek chassis design
l Energy Saving Program (ESP)

Allowable Combinations for AOU18RLXFZ, AOU24RLXFZ, AOU36RLXFZ
52 Combinations Based on BTU
Over 597 Combinations Based on Indoor Type and BTU

ARU9RLF, ARU12RLF,
ARU18RLF, ARU24RLF

ASU7RLF, ASU9RLF,
ASU9RLS2, ASU12RLF,
ASU12RLS2, ASU15RLS2,
ASU18RLF, ASU24RLF

7,000

BTU Capacity
=

9,000

16

7 12

19

9 9

18

9 12

21

7 15

22

9 12
9 15

25
18
21
24

9 18

27

12 12

24

12 15

7 7 18 7 7 24
7 9 12 7 9 15 7 9 18

16
19

9 9 -

7 7 15 -

14

7 12 -

7 18

15,000

18,000

27

7 7 7

21

7 7 9

23

7 7 12

26

7 9 9

25

9 9 9

27

AOU18RLXFZ
AOU24RLXFZ
AOU36RLXFZ

24,000

36

AOU36RLXFZ
12 12 15

39

29

7 7 7 7

28

32

7 7 7 9

30

38

7 7 7 12

33

28

7 7 7 15

36

31

7 7 7 18 **

39

7 7 9 9

32

7 7 9 12

35

34

4 ROOMS

7 9

18*18*

4 ROOMS

2 ROOMS

14

7 9 -

12,000

AOU36RLXFZ

7 7

AOU24RLXFZ
7 7 -

AUU9RLF
AUU12RLF
AUU18RLF

Allowed "Connectable Capacity" combinations between 100 and 130%

AOU18RLXFZ

3 ROOMS

NEW

7 12 12 -

31

7 12 15

34

7 7 9 15

38

7 12 18

37

7 7 12 12

38

9 9 9 -

27

7 9 9 9

34

9 9 12 -

30

7 9 9 12

37

9 9 15

33

9 9 9 9

36

9 9 18

37

9 12 12

33

9 12 15

36

9 12 18

39

12 12 12

36

Remember: These systems
do not require branch boxes
or separation tube assemblies.

*The optional kit “K9FZ1818 (UTP-MU36A2)” is necessary for dual zone system “18+18”. **Wall mounted type ASU18RLF can not be connected in this
combination. “-” represents available circuit for future expansion when connecting this combination.

3

Multi-Zone Outdoor Units 18, 24 and 36,000 BTUs
AOU18RLXFZ, AOU24RLXFZ, AOU36RLXFZ
AOU
AOU
AOU
18RLXFZ 24RLXFZ 36RLXFZ
Connectable Indoor Unit Number
Connectable Unit Capacity Class BTU/h
Rated Capacity Cooling/Heating BTU/h

Clg. Operating Range °F(°C)

AOU36RLXFZ

Htg. Operating Range °F(°C)

AOU18, 24RLXFZ

Compact Size
The compact size of the outdoor
units allows for many installation
opportunities.

24” minimum
clearance
required

Input Power: Clg/Htg Rated kW*
Voltage/Frequency/Phase
Current: Total Max. (A)
Minimum Circuit Ampacity (A)
Recommended Fuse Size (A)
Outdoor Fan Airflow CFM (Clg/Htg)
Fan: Type x Quantity
Sound Pressure Level Cooling dB(A)
Sound Pressure Level Heating dB(A)
Pre-Charge Length Total Ft (m)
Max. Length Total Ft (m)
Max. Length Each Ft (m)
Min. Length Total Ft (m)
Min. Length Each Ft (m)
Max. Pipe Height Difference Between
Outdoor Unit & Farthest Indoor Ft (m)
Max. Pipe Height Difference
Between Indoor Units Ft (m)
Connection Method
Conn. Pipe Diameter Inch
Net Weight lbs. (kg)
Dimensions: Height Inch
mm

DC Twin Rotary
Compressor

Width Inch
mm

Depth Inch

A high performance, low noise,
large capacity
DC twin rotary
compressor is
used.

mm
Refrigerant

AOU
36RLXFZ

Heat Pump

Heat Pump

Heat Pump

18+18 Combo1

ASU9+ASU9

ASU9+ASU7+ASU7

ASU9 x 4

ASU18+ASU18

2
14 to 21,0002
18,000/22,000
14 to 115
(-10 to 46)
5 to 75
(-15 to 24)
1.44/1.87
208-230/60/1
10.0
13
25
1,795/1,619
Propeller x 1
49
49
98 (30)
164 (50)
82 (25)
49 (15)
16 (5)

2 to 3
3 to 4
14 to 27,0002 27 to 39,0002
22,000/24,000 35,200/36,400
14 to 115
32 to 115
(-10 to 46)
(0 to 46)
5 to 75
14 to 75
(-15 to 24)
(-10 to 24)
1.76/1.73
4.00/3.00
208-230/60/1 208-230/60/1
13.7
20.1
17
25
25
30
1,942/1,942
2,119/2,237
Propeller x 1
Propeller x 1
51
53
52
55
98 (30)
164 (50)
164 (50)
230 (70)
82 (25)
82 (25)
49 (15)
66 (20)
16 (5)
16 (5)

21
36,0001
31,600/35,800
50 to 115
(10 to 46)
14 to 75
(-10 to 24)
3.98/3.66
208-230/60/1
20.1
25
30
2,119/2,237
Propeller x 1
53
55
66 (20)
131 (40)
82 (25)
49 (15)
25 (7.5)

49 (15)

49 (15)

49 (15)

49 (15)

33 (10)

33 (10)

33 (10)

33 (10)

Flare

Flare
Liq. 1/4 x 3
Suc. 1/2 x 1,
3/8 x 2
124 (56)
27-9/16
700
35-7/16
900
13
330
R410A

Flare
Liq. 1/4 x 4
Suc. 1/2 x 1,
3/8 x 3
149 (68)
32-11/16
830
35-7/16
900
13
330
R410A

Flare

Liq. 1/4 x 2
Suc. 3/8 x 2
119 (54)
27-9/16
700
35-7/16
900
13
330
R410A

Liq. 3/8 x 2
Suc. 1/2 x 21
149 (68)
32-11/16
830
35-7/16
900
13
330
R410A

1

2

18+18 is the only 2 indoor unit (ASU, ARU or AUU) combination and requires K9FZ1818.
See Design & Technical Manual for allowed combinations within this connectable capacity range.

Nominal Capacities, SEER and HSPF Ratings
Data below is based on AHRI 210/240 non-ducted wall mounted models.
Indoor Unit

Model

AOU18RLXFZ

Type
Non-Ducted
Ducted
Mixed
Specific

AOU24RLXFZ

AOU36RLXFZ

Non-Ducted
Ducted
Mixed
Non-Ducted
Ducted
Mixed

Combination
ASU9+ASU9
ASU7+ASU12 and
ASU9+ASU12
ASU9+ASU7+ASU7
-

Yellow rows represent models that are ENERGY STAR® Qualified.

4

Cooling
Capacity
Btu/h
95◦F
18,000
18,000
18,000

12.50
12.10
12.30

18,000
22,000
22,000
22,000
35,200
33,800
34,400

EER

SEER

Heating Capacity
Btu/h

COP

HSPF

18.0
16.0
17.0

47◦F
22,000
22,000
22,000

17◦F
13,900
13,900
13,900

47◦F
3.44
3.52
3.48

9.3
9.0
9.2

12.50

18.0

22,000

13,900

3.67

9.0

12.50
10.60
11.55
8.80
8.10
8.45

18.0
15.5
16.8
16.0
14.5
15.3

24,000
24,000
24,000
36,400
36,400
36,400

14,100
14,100
14,100
22,000
21,200
21,600

4.04
3.42
3.74
3.56
3.08
3.32

9.5
9.0
9.3
9.4
8.7
9.1

Wall Mounted 7, 9, 12, 18 and 24,000 BTUs
ASU7RLF, ASU9RLF, ASU9RLS2, ASU12RLF, ASU12RLS2, ASU15RLS2,
ASU18RLF, ASU24RLF

ASU7, 9, 12RLF

ASU9, 12, 15RLS2^

ASU18, 24RLF

Designer Series

ASU7RLF ASU9RLF ASU12RLF ASU18RLF ASU24RLF ASU9RLS2 ASU12RLS2 ASU15RLS2
Heat Pump

Heat Pump^

Heat Pump^

Heat Pump^

7,000
9,000
12,000
18,000
24,000
9,000
Nominal Cooling BTU/h*
8,100
10,200
13,500
20,000
27,000
10,200
Nominal Heating BTU/h*
Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1

12,000
13,500
208-230/60/1

14,000
16,300
208-230/60/1

Air Circ. C.F.M. (m3/h): Hi
Medium
Low
Quiet

Heat Pump

Heat Pump

Heat Pump

Heat Pump

Clg 330 (560)
Htg 330 (560)
Clg 294 (500)
Htg 294 (500)
Clg 253 (430)
Htg 253 (430)

Clg 353 (600)
Htg 353 (600)
Clg 306 (520)
Htg 306 (520)
Clg 253 (430)
Htg 253 (430)

Clg 388 (660)
Htg 388 (660)
Clg 330 (560)
Htg 330 (560)
Clg 265 (450)
Htg 277 (470)

Clg 542 (920)
Htg 542 (920)
Clg 436 (740)
Htg 436 (740)
Clg 365 (620)
Htg 365 (620)

Clg 659 (1,120)
Htg 647 (1,100)
Clg 530 (900)
Htg 530 (900)
Clg 436 (740)
Htg 436 (740)

Clg 353 (600)
Htg 353 (600)
Clg 324 (550)
Htg 324 (550)
Clg 277 (470)
Htg 277 (470)

Clg 388 (660)
Htg 388 (660)
Clg 353 (600)
Htg 353 (600)
Clg 312 (530)
Htg 312 (530)

Clg 418 (710)
Htg 418 (710)
Clg 377 (640)
Htg 377 (640)
Clg 336 (570)
Htg 347 (590)

Clg 200 (340)
Htg 206 (350)

Clg 200 (340)
Htg 206 (350)

Clg 200 (340)
Htg 206 (350)

Clg 324 (550)
Htg 324 (550)

Clg 365 (620)
Htg 365 (620)

Clg 194 (330)
Htg 194 (330)

Clg 194 (330)
Htg 194 (330)

Clg 230 (390)
Htg 253 (430)

36/36

37/37

40/40

43/44

49/48

36/36

37/37

41/41

Noise Level
dB(A) (Clg/Htg): Hi

Medium
32/32
33/33
36/36
37/37
42/42
32/32
34/34
36/36
29/29
29/29
30/31
33/33
37/37
28/28
31/31
33/34
Low
Quiet
25/25
25/25
25/25
31/31
33/33
21/21
21/21
25/27
Running Current
0.13
0.15
0.19
0.32
0.53
0.14
0.17
0.20
Rated (A): Cooling
Heating
0.13
0.15
0.19
0.32
0.53
0.14
0.17
0.20
Power Use Rated (w): Clg
15
17
22
41
69
16
19
23
Htg
15
17
22
41
69
16
19
23
Fan Speeds Stage
4+auto
4+auto
4+auto
4+auto
4+auto
4+auto
4+auto
4+auto
Air Direction: Horizontal
Manual
Manual
Manual
Auto
Auto
Manual
Manual
Manual
Vertical
Auto
Auto
Auto
Auto
Auto
Auto
Auto
Auto
Washable
Washable
Washable
Washable
Washable
Washable
Washable
Washable
Primary Air Filter
Disposable
Disposable
Disposable
Disposable
Disposable
Disposable
Disposable
Ion Deodorizing Filter Disposable
Disposable
Disposable
Disposable
Disposable
Disposable
Disposable
Disposable
Apple-Catechin Filter Disposable
Flare
Flare
Flare
Flare
Flare
Flare
Flare
Flare
Connection Method
Conn. Pipe Diameter Inch suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 1/2 dis 1/4 suc 5/8 dis 1/4 suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 1/2 dis 1/4
18 (8)
18 (8)
18 (8)
31 (14)
31 (14)
21 (9.5)
21 (9.5)
21 (9.5)
Net Weight lbs. (kg)
11-1/8 (282)
11-1/8 (282)
11-1/8 (282)
Dims: Height Inch (mm) 11-1/16 (280) 11-1/16 (280) 11-1/16 (280) 12-5/8 (320) 12-5/8 (320)
13-1/4* (337*)
13-1/4* (337*)
13-1/4* (337*)
Width Inch (mm) 31-1/16 (790) 31-1/16 (790) 31-1/16 (790) 39-1/4 (998) 39-1/4 (998) 34-1/4 (870)
34-1/4 (870)
34-1/4 (870)
Depth Inch (mm)
8 (203)
8 (203)
8 (203)
9 (228)
9 (228)
7-1/4 (185)
7-1/4 (185)
7-1/4 (185)
R410A
R410A
R410A
R410A
R410A
R410A
R410A
R410A
Refrigerant
^Not compatible with outdoor unit AOU48RLXFZ.

*Height when front panel is open.

Standard Features

Built In Filtration

l
l
l
l
l
l
l
l

Long-life+ Ion Deodorization Filter
The filter deodorizes by powerfully
decomposing absorbed odors using
the oxidizing and reducing effects of
ions generated by the ultra-fineparticle ceramic.

l
l
l

Wireless Remote Control*
Apple Catechin Filter
Ion Deodorizing Filter
Sleep Timer
24-Hour Timer
Dry Mode
Auto Louver: 4-Way**
Auto Mode
Minimum Heat Mode
Auto Restart/Reset
Power Diffuser**

Apple-Catechin Filter
Dust, mold spores and microorganisms are absorbed onto the
filter by static electricity and growth
is inhibited and deactivated.

+ The filter can be used for approximately 3 years if it is washed with water when dirty to restore it's surface action.

* Features vary by model and therefore standard
wireless remote controls should be used with the
models they are associated with.
**Feature of models ASU18, 24RLF only.

5

Compact Duct 9, 12, 18 and 24,000 BTUs
ARU9RLF, ARU12RLF, ARU18RLF, ARU24RLF
Compact Duct
ARU9, 12RLF

ARU18RLF

Adaptable when ceiling cavity
is small and there is no slope
for drain.

ARU24RLF

ARU9RLF ARU12RLF ARU18RLF ARU24RLF
Nominal Cooling BTU/h
Nominal Heating BTU/h
Voltage/Frequency/Phase
Recommended Static Pressure In. W. C.
Air Circ. C.F.M. (m3/h) Clg/Htg: Hi
Medium
Low
Quiet
Noise Level dB(A) (Clg/Htg): Hi
Medium
Low
Quiet
Running Current Rated (A): Cooling
Heating
Power Use Rated (W): Cooling
Heating
Fan Speeds Stage
Air Filter
Connection Method
Conn. Pipe Diameter Inch
Net Weight lbs. (kg)

Heat Pump

Heat Pump

Heat Pump

Heat Pump

9,000
10,200
208-230/60/1
0 ~ 0.36
353 (600)
324 (550)
294 (500)
265 (450)
28/28
27/26
26/25
25/24
0.30
0.30
49
49
4 + Auto
Washable
Flare
suc 3/8 dis 1/4
41 (19)
7-25/32 (198)
27-9/16 (700)

12,000
13,500
208-230/60/1
0 ~ 0.36
383 (650)
353 (600)
324 (550)
283 (480)
29/29
28/28
27/27
26/24
0.35
0.35
58
58
4 + Auto
Washable
Flare
suc 3/8 dis 1/4
41 (19)
7-25/32 (198)
27-9/16 (700)

18,000
20,000
208-230/60/1
0 ~ 0.36
554 (940)
518 (880)
483 (820)
442 (750)
32/33
31/32
30/31
29/29
0.44
0.44
73
73
4 + Auto
Washable
Flare
suc 1/2 dis 1/4
50 (23)
7-25/32 (198)
35-7/16 (900)

24,000
27,000
208-230/60/1
0 ~ 0.20
783 (1,330)
730 (1,240)
648 (1,100)
607 (1,030)
33/35
32/34
30/32
29/29
0.66
0.66
111
111
4 + Auto
Washable
Flare
suc 5/8 dis 1/4
59 (27)
7-25/32 (198)
43-5/16 (1,100)

24-13/32 (620)

24-13/32 (620)

24-13/32 (620)

5-15/16 (151)

5-15/16 (151)

5-15/16 (151)

25-19/32 (650)
3/4 (19)

33-15/32 (850) 41-11/32 (1,050)
3/4 (19)
3/4 (19)

6-27/32 (174)

6-27/32 (174)

6-27/32 (174)

Dimensions: Height Inch (mm)
Width Inch (mm)
Depth Inch (mm) 24-13/32 (620)
Supply Duct Flange
5-15/16 (151)
Dimensions: Height Inch (mm)
Width Inch (mm) 25-19/32 (650)
Depth Inch (mm)
3/4 (19)
Return Duct Flange
6-27/32 (174)
Dimensions: Height Inch (mm)
Width Inch (mm) 22-19/32 (574)
Depth Inch (mm)
Refrigerant

Traditional
Drain
Pump

13”

Compact Duct

9.4”

Return Air-intake Choices
Bottom

Back

Standard Features
l

Dry Mode
Weekly Timer
Sleep Timer*
24-Hour Timer*
Minimum Heat Mode*
Auto Mode
Quiet Mode
Auto Restart/Reset
Auto Changeover
Condensate Pump
Fresh Air Intake

l
l
l
l
l
l

22-19/32 (574)

30-15/32 (774)

38-11/32 (974)

l
l
l

3/4 (19) (Flat)

3/4 (19) (Flat)

3/4 (19) (Flat)

3/4 (19) (Flat)

l

R410A

R410A

R410A

R410A
*Available only with optional wireless
remote control.

Field Supplied Filters Used With Compact Duct Units

Filters are sized to keep velocities and
static pressure loss low. This will insure
sufficient static pressure is available for
ductwork, fittings and supply and return
grilles. lternative filter sizes with
equivalent face areas can be used.
After deducting filter loss, available
static pressure values are shown.

6

A fiberglass filter is shown in
blue to the left. A MERV pleated
filter is shown in white.

ARU
ARU
ARU
24RLF
18RLF
12RLF
806
547
353
18 x 30
14 x 25
12 x 20
215
225
212
0.20
0.36
0.36
1" Fiberglass Filter
0.04
0.04
0.04
0.16
0.32
0.32
1" MERV 8 Pleated Filter
0.13
0.14
0.12
0.07
0.22
0.24
2" MERV 8 Pleated Filter
0.07
0.08
0.07
0.13
0.28
0.29

CFM
Typical Filter Size
Velocity, FPM
Unit External SP, in. W.C.

ARU
9RLF
353
12 x 20
212
0.36

SP Loss, in. W.C.
Available Static Pressure

0.04
0.32

SP Loss, in. W.C.
Available Static Pressure

0.12
0.24

SP Loss, in. W.C.
Available Static Pressure

0.07
0.29

Compact Duct Units require field supplied filters. They can be installed
at the unit or for more convenient servicing, in filter grilles. The chart
to the right provides guidelines for determining filter sizes.

Compact Cassettes 9, 12, and 18,000 BTUs
AUU9RLF, AUU12RLF, AUU18RLF

Easy Installation
Fits into a standard ceiling tile*.
Compact cassette and compact duct
models can be networked.

AUU9RLF AUU12RLF AUU18RLF
22.5”

22.5”

Nominal Cooling BTU/h

20,000

318 (540)
Clg or Htg
288 (490)
Clg or Htg
259 (440)
Clg or Htg
230 (390)
Clg or Htg

359 (610)
Clg or Htg
312 (530)
Clg or Htg
277 (470)
Clg or Htg
241 (410)
Clg or Htg

441 (750) Clg
471 (800) Htg
359 (610) Clg
418 (710) Htg
306 (520) Clg
353 (600) Htg
241 (410) Clg
265 (450) Htg

Noise Level dB(A) Clg/Htg: Hi

33/34

37/37

42/44

Medium

31/32

33/33

37/40

Low

29/29

31/31

33/37

Quiet

27/27

28/28

29/30

Rated (A): Cooling

0.15

0.19

0.30

Heating

Medium
Low

1-stage
Running Current

l
l
l
l
l
l
l
l
l
l
l
l

Sleep Timer
Dry Mode
Auto Louver: Up/ Down
Quiet Mode
Auto Restart/Reset
Auto Changeover
Remote Temperature Sensor
High Ceiling Mode
Condensate Pump
2-Stage Turbo Fan
Minimum Heat Mode+
Fresh Air Intake**

18,000

208-230/60/1

Quiet

Standard Features

12,000
13,500

2-Stage Turbo Fan

Increased 20%

9,000

208-230/60/1

*Dimensions of outer grille are 27-9/16” x 27-9/16”
and may overlap adjacent tiles.

Heat exchange
efficiency:

Heat Pump

10,200

Air Circ. C.F.M. (m3/h): Hi

2-stage

Heat Pump

208-230/60/1

Nominal Heating BTU/h
Voltage/Frequency/Phase

Air distribution is evenly spread across
the heat exchanger by the new 2 stage
turbo fan which produces two separate
airflow streams.

Heat Pump

Power Use

0.15

0.19

0.30

Rated/Max (W): Clg

18

23

39

Heating

18

23

39

Fan Speeds Stage

4+auto

4+auto

4+auto

Air Direction: Vertical

Automatic

Automatic

Automatic

Air Filter

Washable

Washable

Washable

UTG-CCGF*

UTG-CCGF*

UTG-CCGF*

Front Grille
Connection Method
Conn. Pipe Diameter Inch
Net Weight lbs. (kg)

Flare

Flare

Flare

suc 3/8 dis 1/4

suc 3/8 dis 1/4

suc 1/2 dis 1/4

33 (15)

33 (15)

33 (15)

Chassis Dim: Height Inch (mm)

9-11/16 (245)

9-11/16 (245)

9-11/16 (245)

Width Inch (mm)

22-7/16 (570)

22-7/16 (570)

22-7/16 (570)

Depth Inch (mm)

22-7/16 (570)

22-7/16 (570)

22-7/16 (570)

Grille Dim: Height Inch (mm)

1-15/16 (49)

1-15/16 (49)

1-15/16 (49)

Width Inch (mm)

27-9/16 (700)

27-9/16 (700)

27-9/16 (700)

Depth Inch (mm)

27-9/16 (700)

27-9/16 (700)

27-9/16 (700)

R410A

R410A

R410A

Refrigerant
+ Available only with optional wireless remote control.
**Requires Fujitsu’s Optional Fresh Air Kit part #UTZ-VXAA. Allows for a 4 – inch flex duct connection
and a field supplied duct booster fan. Fresh air maximum is 10% of unit High fan CFM. See
UTZ-VXAA Design and Technical Manual for fan static pressure requirements at Fresh Air Kit. Add
hood, filter and duct losses for fan total static pressure requirements. Will add 4” to the height of the
indoor unit.
* Compact Cassette Grille UTG-CCGF sold separately. Must order one with each compact cassette.

Fresh Air Kit**
UTZ-VXAA
Mixes room air then passes
through the heat exchanger.

7

Optional Accessories
Wired Remote
Controller*

Simple Remote
Controller

Wireless Remote
Controller

UTY-RNNUM^

UTY-RSNUM*

UTY-LNHUM

The wired remote controller with its unique
lock function and sleek design provides full
feature access to property managers,
building owners, and facility maintenance,
as well as providing basic comfort features
to tenants, employees, and teachers.

Suitable when only basic operations
are required for hotels, offices and
other places where there is frequent
arrival and departure of occupants.

For spaces where there is just no place to
mount the wired remote.

Dry Contact Wire Kit*

Interface Kit

Interface Kit

UTY-XWZX / UTY-XWZXZ5

UTY-TWBXF**

UTY-XCBXZ1**

Turns system on or off using a normally
closed circuit, for example in home
automation or BMS integration of only
On/Off operation, occupancy sensor or key
card switch or lead-lag control of other
heating/cooling.

Required to connect the ASU9RLS2,
ASU12RLS2 and ASU15RLS2 to Wired
Remote UTY-RNNUM, Dry Contact Wire
Kit UTY-XWZXZ5, and Simple Remote
Control UTY-RSNUM.

Required to connect ASU7RLF, 9RLF,
12RLF and ASU15RLS to Wired Remote
UTY-RNNUM, Dry Contact Wire Kit
UTY-XWZX, and Simple Remote
Control UTY-RSNUM.

High Humidity
Insulation Kit

Fresh Air
Intake Kit

Air Outlet
Shutter Plate

UTZ-KXGC

UTZ-VXAA

UTR-YDZB

Additional insulation for compact cassette
units, which may be needed when they
are installed in high humidity areas.

Mixes room air then passes it through a
heat exchanger.

Receiver Unit

Remote Sensor

UTY-LRHUM

UTY-XSZX

Includes a wireless remote
control.

Wall mounted temperature
sensor for compact duct
models.

In a 3-way air flow configuration an Air
Outlet Shutter Plate kit is required.

Compact Duct
Connector Kit

18+18 Combo
Fittings Kit

UTD-ECS5A

K9FZ1818

Comes with 5 sets of wires. Can
be used to turn unit on/off, wire
in float switch, AUX heater, turn
on an external device (Fan), or
show if the unit is running.

Allows two 18,000 BTU indoor
units to be used on an outdoor
AOU36RLXFZ. Requires special
piping; limited to only 18,000
BTU models. Total BTU capacity
is limited to 35,800 BTU.

Compatibility:
Small Wall Mount

Designer Wall Mount

Large Wall Mount

Compact Cassette

Compact Duct

7,9,12k BTU / RLF Series

9,12, 15k BTU / RLS2 Series

18, 24k BTU

9, 12, 18k BTU

9, 12, 18, 24k BTU

^ Minimum Heat, Sleep Timer functions will be lost when the wired remote controller is installed.
* Wall mounted ASU7, 9, and 12RLF require accessory interface kit (Part UTY-XCBXZ1) in order to connect this device to them. Wall mounted ASU9, 12,
and 15RLS2 require accessory interface kit (Part UTY-TWBXF) in order to connect this device to them.
** Internal thermosensor function in Wired Remote UTY-RNNUM is disabled when using this interface kit.

The Fujitsu logo is a registered trademark of Fujitsu Limited. The Halcyon HFI logo and name is a
trademark of Fujitsu General America, Inc. Copyright © 2013 Fujitsu General America, Inc. Fujitsu’s
products are subject to continuous improvements.  Fujitsu reserves the right to modify product design,
specifications and information in this brochure without notice and without incurring any obligations.
PLEASE NOTE: Internet sales are strictly prohibited and unauthorized. Any HVAC systems purchased on
the Internet, from an online retailer or any similar e-tailing website, OR where the original factory serial
numbers of the display have been removed, defaced, or replaced in any way WILL NOT BE COVERED BY
WARRANTY.

Fujitsu General America, Inc.
353 Route 46 West
Fairfield, NJ 07004
Toll Free: (888) 888-3424
Local: (973) 575-0380
Fax: (973) 836-0447
Email: hvac@fujitsugeneral.com
www.fujitsugeneral.com
A subsidiary of

Printed in the USA Rev. 3/13
Part #6-26-FG2038

Fujitsu General Limited



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2013:03:12 10:20:13-04:00
Create Date                     : 2013:03:12 10:20:13-04:00
Format                          : application/pdf
Title                           : HFI_Multi_Brochure_1-2013_Layout 1
Creator                         : emezle
Document ID                     : uuid:009ce10e-6898-43d2-b009-1baf96e2d46a
Instance ID                     : uuid:9f13f6b2-6239-4fe8-a130-e625203d948e
Page Count                      : 8
Author                          : emezle
EXIF Metadata provided by EXIF.tools

Navigation menu