Fujitsu Aou18Rlxfz Users Manual HFI_Multi_Brochure_1 2013_
2015-01-25
: Fujitsu Fujitsu-Aou18Rlxfz-Users-Manual-218164 fujitsu-aou18rlxfz-users-manual-218164 fujitsu pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | ![]() |
Open PDF In Browser | View PDF |
Hybrid Flex Inverter System Dual, Tri and Quad Zone Mix & Match Flexibility Includes RLS2 Designer Series Indoor Models ! NEW Mini-Split Air Conditioners and Heat Pumps AOU18RLXFZ AOU24RLXFZ AOU36RLXFZ Use mini-splits just about any place that requires comfort! Older homes l New construction homes l Schools l Places of worship Hospitals and medical facilities l Restaurants l Computer rooms Hotels and motels l Car washes l Convenience stores Fast food chains l Fire houses l Police stations l Oil rigs l Bars Sunrooms and additions l Warehouses l Nursing homes ATM vestibules l Small offices... Hybrid Flex Inverter System Zoned Mix and Match Flexibility multi 18, 24, 36,000 BTUs AOU18RLXFZ, AOU24RLXFZ, AOU36FLXFZ Contractors can select either an 18, 24 or 36,000 BTU outdoor unit combined with wall mounted, compact cassette or compact duct type indoor units. Mix-andmatch flexibility of evaporator type and capacity allows you to choose the indoor unit that best fits the application, whether it be hidden or showcased. These systems are ideal for nursing homes, doctor's offices, condominiums, apartments and residences - any place where individual cooling or heating is needed. Features l Part of the Halcyon Hybrid Flex Inverter (HFI) Line As part of the HFI line of components, indoor units are compatible with other HFI outdoor units, meaning mix and match capabilities with fewer components. l No Branch Boxes or Separation Tube Assemblies While the 8-zone AOU48RLXFZ1 model requires both branch boxes and separation tube assembly kits, the smaller zoned units - AOU18, 24 and 36RLXFZ do not require them. l Pricing Compared to Competition Additional outdoor units provides better matched BTU capacity with indoor units. By better matching the outdoor unit to the indoor capacity a better system value is achieved. l High Efficiency Systems Up to 18-SEER in efficiency, these units are 22% more efficient than 14-SEER competing multi-zone systems. l Why Choose an 18,000 BTU Zoned System? A lower BTU dual zone is often the perfect solution to a comfort need. A consumer shouldn’t have to purchase a higher priced larger unit when only 14 to 18,000 BTU’s are needed. l Connectable Capacity Our 3 outdoor units provide systems from 14,000 to 39,000 BTU. Some connectable capacity is provided to allow increased combinations and flexibility. All indoor units can operate at once, how ever if all the evaporators are calling for cooling or heating at the same time it will decrease the capacity of each evaporator not to exceed the condenser’s capacity. As zones meet desired set point the system’s other evaporators increase output up to the evaporator’s rated capacity. l A Tri-Zone 24,000 BTU Unit Fujitsu offers a 2-ton system that provides 2 or 3-zone flexibility. By using connectable capacity, this system allows up to three 9,000 BTU units. For example: The load on a 3-bedroom home with a living room and kitchen downstairs and 3 bedrooms upstairs is 39,000 BTUs (21,000 BTU downstairs and 18,000 BTU upstairs). However the family isn’t upstairs and downstairs at the same time, therefore not all units will be running simultaneously allowing 100% heating or cooling to occupied spaces. This can be achieved by our AOU36RLFXZ outdoor unit. 2 ! RLS2 Designer Series Compatibility Wall Mounted ASU9RLS2, ASU12RLS2, ASU15RLS2 Fujitsu’s indoor RLS2 models are now compatible with outdoor multizone units so contractors can choose between different wall mounted styles as well as different evaporator styles (wall mounted, compact cassette or compact duct). Features: l Sleek chassis design l Energy Saving Program (ESP) Allowable Combinations for AOU18RLXFZ, AOU24RLXFZ, AOU36RLXFZ 52 Combinations Based on BTU Over 597 Combinations Based on Indoor Type and BTU ARU9RLF, ARU12RLF, ARU18RLF, ARU24RLF ASU7RLF, ASU9RLF, ASU9RLS2, ASU12RLF, ASU12RLS2, ASU15RLS2, ASU18RLF, ASU24RLF 7,000 BTU Capacity = 9,000 16 7 12 19 9 9 18 9 12 21 7 15 22 9 12 9 15 25 18 21 24 9 18 27 12 12 24 12 15 7 7 18 7 7 24 7 9 12 7 9 15 7 9 18 16 19 9 9 - 7 7 15 - 14 7 12 - 7 18 15,000 18,000 27 7 7 7 21 7 7 9 23 7 7 12 26 7 9 9 25 9 9 9 27 AOU18RLXFZ AOU24RLXFZ AOU36RLXFZ 24,000 36 AOU36RLXFZ 12 12 15 39 29 7 7 7 7 28 32 7 7 7 9 30 38 7 7 7 12 33 28 7 7 7 15 36 31 7 7 7 18 ** 39 7 7 9 9 32 7 7 9 12 35 34 4 ROOMS 7 9 18*18* 4 ROOMS 2 ROOMS 14 7 9 - 12,000 AOU36RLXFZ 7 7 AOU24RLXFZ 7 7 - AUU9RLF AUU12RLF AUU18RLF Allowed "Connectable Capacity" combinations between 100 and 130% AOU18RLXFZ 3 ROOMS NEW 7 12 12 - 31 7 12 15 34 7 7 9 15 38 7 12 18 37 7 7 12 12 38 9 9 9 - 27 7 9 9 9 34 9 9 12 - 30 7 9 9 12 37 9 9 15 33 9 9 9 9 36 9 9 18 37 9 12 12 33 9 12 15 36 9 12 18 39 12 12 12 36 Remember: These systems do not require branch boxes or separation tube assemblies. *The optional kit “K9FZ1818 (UTP-MU36A2)” is necessary for dual zone system “18+18”. **Wall mounted type ASU18RLF can not be connected in this combination. “-” represents available circuit for future expansion when connecting this combination. 3 Multi-Zone Outdoor Units 18, 24 and 36,000 BTUs AOU18RLXFZ, AOU24RLXFZ, AOU36RLXFZ AOU AOU AOU 18RLXFZ 24RLXFZ 36RLXFZ Connectable Indoor Unit Number Connectable Unit Capacity Class BTU/h Rated Capacity Cooling/Heating BTU/h Clg. Operating Range °F(°C) AOU36RLXFZ Htg. Operating Range °F(°C) AOU18, 24RLXFZ Compact Size The compact size of the outdoor units allows for many installation opportunities. 24” minimum clearance required Input Power: Clg/Htg Rated kW* Voltage/Frequency/Phase Current: Total Max. (A) Minimum Circuit Ampacity (A) Recommended Fuse Size (A) Outdoor Fan Airflow CFM (Clg/Htg) Fan: Type x Quantity Sound Pressure Level Cooling dB(A) Sound Pressure Level Heating dB(A) Pre-Charge Length Total Ft (m) Max. Length Total Ft (m) Max. Length Each Ft (m) Min. Length Total Ft (m) Min. Length Each Ft (m) Max. Pipe Height Difference Between Outdoor Unit & Farthest Indoor Ft (m) Max. Pipe Height Difference Between Indoor Units Ft (m) Connection Method Conn. Pipe Diameter Inch Net Weight lbs. (kg) Dimensions: Height Inch mm DC Twin Rotary Compressor Width Inch mm Depth Inch A high performance, low noise, large capacity DC twin rotary compressor is used. mm Refrigerant AOU 36RLXFZ Heat Pump Heat Pump Heat Pump 18+18 Combo1 ASU9+ASU9 ASU9+ASU7+ASU7 ASU9 x 4 ASU18+ASU18 2 14 to 21,0002 18,000/22,000 14 to 115 (-10 to 46) 5 to 75 (-15 to 24) 1.44/1.87 208-230/60/1 10.0 13 25 1,795/1,619 Propeller x 1 49 49 98 (30) 164 (50) 82 (25) 49 (15) 16 (5) 2 to 3 3 to 4 14 to 27,0002 27 to 39,0002 22,000/24,000 35,200/36,400 14 to 115 32 to 115 (-10 to 46) (0 to 46) 5 to 75 14 to 75 (-15 to 24) (-10 to 24) 1.76/1.73 4.00/3.00 208-230/60/1 208-230/60/1 13.7 20.1 17 25 25 30 1,942/1,942 2,119/2,237 Propeller x 1 Propeller x 1 51 53 52 55 98 (30) 164 (50) 164 (50) 230 (70) 82 (25) 82 (25) 49 (15) 66 (20) 16 (5) 16 (5) 21 36,0001 31,600/35,800 50 to 115 (10 to 46) 14 to 75 (-10 to 24) 3.98/3.66 208-230/60/1 20.1 25 30 2,119/2,237 Propeller x 1 53 55 66 (20) 131 (40) 82 (25) 49 (15) 25 (7.5) 49 (15) 49 (15) 49 (15) 49 (15) 33 (10) 33 (10) 33 (10) 33 (10) Flare Flare Liq. 1/4 x 3 Suc. 1/2 x 1, 3/8 x 2 124 (56) 27-9/16 700 35-7/16 900 13 330 R410A Flare Liq. 1/4 x 4 Suc. 1/2 x 1, 3/8 x 3 149 (68) 32-11/16 830 35-7/16 900 13 330 R410A Flare Liq. 1/4 x 2 Suc. 3/8 x 2 119 (54) 27-9/16 700 35-7/16 900 13 330 R410A Liq. 3/8 x 2 Suc. 1/2 x 21 149 (68) 32-11/16 830 35-7/16 900 13 330 R410A 1 2 18+18 is the only 2 indoor unit (ASU, ARU or AUU) combination and requires K9FZ1818. See Design & Technical Manual for allowed combinations within this connectable capacity range. Nominal Capacities, SEER and HSPF Ratings Data below is based on AHRI 210/240 non-ducted wall mounted models. Indoor Unit Model AOU18RLXFZ Type Non-Ducted Ducted Mixed Specific AOU24RLXFZ AOU36RLXFZ Non-Ducted Ducted Mixed Non-Ducted Ducted Mixed Combination ASU9+ASU9 ASU7+ASU12 and ASU9+ASU12 ASU9+ASU7+ASU7 - Yellow rows represent models that are ENERGY STAR® Qualified. 4 Cooling Capacity Btu/h 95◦F 18,000 18,000 18,000 12.50 12.10 12.30 18,000 22,000 22,000 22,000 35,200 33,800 34,400 EER SEER Heating Capacity Btu/h COP HSPF 18.0 16.0 17.0 47◦F 22,000 22,000 22,000 17◦F 13,900 13,900 13,900 47◦F 3.44 3.52 3.48 9.3 9.0 9.2 12.50 18.0 22,000 13,900 3.67 9.0 12.50 10.60 11.55 8.80 8.10 8.45 18.0 15.5 16.8 16.0 14.5 15.3 24,000 24,000 24,000 36,400 36,400 36,400 14,100 14,100 14,100 22,000 21,200 21,600 4.04 3.42 3.74 3.56 3.08 3.32 9.5 9.0 9.3 9.4 8.7 9.1 Wall Mounted 7, 9, 12, 18 and 24,000 BTUs ASU7RLF, ASU9RLF, ASU9RLS2, ASU12RLF, ASU12RLS2, ASU15RLS2, ASU18RLF, ASU24RLF ASU7, 9, 12RLF ASU9, 12, 15RLS2^ ASU18, 24RLF Designer Series ASU7RLF ASU9RLF ASU12RLF ASU18RLF ASU24RLF ASU9RLS2 ASU12RLS2 ASU15RLS2 Heat Pump Heat Pump^ Heat Pump^ Heat Pump^ 7,000 9,000 12,000 18,000 24,000 9,000 Nominal Cooling BTU/h* 8,100 10,200 13,500 20,000 27,000 10,200 Nominal Heating BTU/h* Voltage/Frequency/Phase 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 12,000 13,500 208-230/60/1 14,000 16,300 208-230/60/1 Air Circ. C.F.M. (m3/h): Hi Medium Low Quiet Heat Pump Heat Pump Heat Pump Heat Pump Clg 330 (560) Htg 330 (560) Clg 294 (500) Htg 294 (500) Clg 253 (430) Htg 253 (430) Clg 353 (600) Htg 353 (600) Clg 306 (520) Htg 306 (520) Clg 253 (430) Htg 253 (430) Clg 388 (660) Htg 388 (660) Clg 330 (560) Htg 330 (560) Clg 265 (450) Htg 277 (470) Clg 542 (920) Htg 542 (920) Clg 436 (740) Htg 436 (740) Clg 365 (620) Htg 365 (620) Clg 659 (1,120) Htg 647 (1,100) Clg 530 (900) Htg 530 (900) Clg 436 (740) Htg 436 (740) Clg 353 (600) Htg 353 (600) Clg 324 (550) Htg 324 (550) Clg 277 (470) Htg 277 (470) Clg 388 (660) Htg 388 (660) Clg 353 (600) Htg 353 (600) Clg 312 (530) Htg 312 (530) Clg 418 (710) Htg 418 (710) Clg 377 (640) Htg 377 (640) Clg 336 (570) Htg 347 (590) Clg 200 (340) Htg 206 (350) Clg 200 (340) Htg 206 (350) Clg 200 (340) Htg 206 (350) Clg 324 (550) Htg 324 (550) Clg 365 (620) Htg 365 (620) Clg 194 (330) Htg 194 (330) Clg 194 (330) Htg 194 (330) Clg 230 (390) Htg 253 (430) 36/36 37/37 40/40 43/44 49/48 36/36 37/37 41/41 Noise Level dB(A) (Clg/Htg): Hi Medium 32/32 33/33 36/36 37/37 42/42 32/32 34/34 36/36 29/29 29/29 30/31 33/33 37/37 28/28 31/31 33/34 Low Quiet 25/25 25/25 25/25 31/31 33/33 21/21 21/21 25/27 Running Current 0.13 0.15 0.19 0.32 0.53 0.14 0.17 0.20 Rated (A): Cooling Heating 0.13 0.15 0.19 0.32 0.53 0.14 0.17 0.20 Power Use Rated (w): Clg 15 17 22 41 69 16 19 23 Htg 15 17 22 41 69 16 19 23 Fan Speeds Stage 4+auto 4+auto 4+auto 4+auto 4+auto 4+auto 4+auto 4+auto Air Direction: Horizontal Manual Manual Manual Auto Auto Manual Manual Manual Vertical Auto Auto Auto Auto Auto Auto Auto Auto Washable Washable Washable Washable Washable Washable Washable Washable Primary Air Filter Disposable Disposable Disposable Disposable Disposable Disposable Disposable Ion Deodorizing Filter Disposable Disposable Disposable Disposable Disposable Disposable Disposable Disposable Apple-Catechin Filter Disposable Flare Flare Flare Flare Flare Flare Flare Flare Connection Method Conn. Pipe Diameter Inch suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 1/2 dis 1/4 suc 5/8 dis 1/4 suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 1/2 dis 1/4 18 (8) 18 (8) 18 (8) 31 (14) 31 (14) 21 (9.5) 21 (9.5) 21 (9.5) Net Weight lbs. (kg) 11-1/8 (282) 11-1/8 (282) 11-1/8 (282) Dims: Height Inch (mm) 11-1/16 (280) 11-1/16 (280) 11-1/16 (280) 12-5/8 (320) 12-5/8 (320) 13-1/4* (337*) 13-1/4* (337*) 13-1/4* (337*) Width Inch (mm) 31-1/16 (790) 31-1/16 (790) 31-1/16 (790) 39-1/4 (998) 39-1/4 (998) 34-1/4 (870) 34-1/4 (870) 34-1/4 (870) Depth Inch (mm) 8 (203) 8 (203) 8 (203) 9 (228) 9 (228) 7-1/4 (185) 7-1/4 (185) 7-1/4 (185) R410A R410A R410A R410A R410A R410A R410A R410A Refrigerant ^Not compatible with outdoor unit AOU48RLXFZ. *Height when front panel is open. Standard Features Built In Filtration l l l l l l l l Long-life+ Ion Deodorization Filter The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fineparticle ceramic. l l l Wireless Remote Control* Apple Catechin Filter Ion Deodorizing Filter Sleep Timer 24-Hour Timer Dry Mode Auto Louver: 4-Way** Auto Mode Minimum Heat Mode Auto Restart/Reset Power Diffuser** Apple-Catechin Filter Dust, mold spores and microorganisms are absorbed onto the filter by static electricity and growth is inhibited and deactivated. + The filter can be used for approximately 3 years if it is washed with water when dirty to restore it's surface action. * Features vary by model and therefore standard wireless remote controls should be used with the models they are associated with. **Feature of models ASU18, 24RLF only. 5 Compact Duct 9, 12, 18 and 24,000 BTUs ARU9RLF, ARU12RLF, ARU18RLF, ARU24RLF Compact Duct ARU9, 12RLF ARU18RLF Adaptable when ceiling cavity is small and there is no slope for drain. ARU24RLF ARU9RLF ARU12RLF ARU18RLF ARU24RLF Nominal Cooling BTU/h Nominal Heating BTU/h Voltage/Frequency/Phase Recommended Static Pressure In. W. C. Air Circ. C.F.M. (m3/h) Clg/Htg: Hi Medium Low Quiet Noise Level dB(A) (Clg/Htg): Hi Medium Low Quiet Running Current Rated (A): Cooling Heating Power Use Rated (W): Cooling Heating Fan Speeds Stage Air Filter Connection Method Conn. Pipe Diameter Inch Net Weight lbs. (kg) Heat Pump Heat Pump Heat Pump Heat Pump 9,000 10,200 208-230/60/1 0 ~ 0.36 353 (600) 324 (550) 294 (500) 265 (450) 28/28 27/26 26/25 25/24 0.30 0.30 49 49 4 + Auto Washable Flare suc 3/8 dis 1/4 41 (19) 7-25/32 (198) 27-9/16 (700) 12,000 13,500 208-230/60/1 0 ~ 0.36 383 (650) 353 (600) 324 (550) 283 (480) 29/29 28/28 27/27 26/24 0.35 0.35 58 58 4 + Auto Washable Flare suc 3/8 dis 1/4 41 (19) 7-25/32 (198) 27-9/16 (700) 18,000 20,000 208-230/60/1 0 ~ 0.36 554 (940) 518 (880) 483 (820) 442 (750) 32/33 31/32 30/31 29/29 0.44 0.44 73 73 4 + Auto Washable Flare suc 1/2 dis 1/4 50 (23) 7-25/32 (198) 35-7/16 (900) 24,000 27,000 208-230/60/1 0 ~ 0.20 783 (1,330) 730 (1,240) 648 (1,100) 607 (1,030) 33/35 32/34 30/32 29/29 0.66 0.66 111 111 4 + Auto Washable Flare suc 5/8 dis 1/4 59 (27) 7-25/32 (198) 43-5/16 (1,100) 24-13/32 (620) 24-13/32 (620) 24-13/32 (620) 5-15/16 (151) 5-15/16 (151) 5-15/16 (151) 25-19/32 (650) 3/4 (19) 33-15/32 (850) 41-11/32 (1,050) 3/4 (19) 3/4 (19) 6-27/32 (174) 6-27/32 (174) 6-27/32 (174) Dimensions: Height Inch (mm) Width Inch (mm) Depth Inch (mm) 24-13/32 (620) Supply Duct Flange 5-15/16 (151) Dimensions: Height Inch (mm) Width Inch (mm) 25-19/32 (650) Depth Inch (mm) 3/4 (19) Return Duct Flange 6-27/32 (174) Dimensions: Height Inch (mm) Width Inch (mm) 22-19/32 (574) Depth Inch (mm) Refrigerant Traditional Drain Pump 13” Compact Duct 9.4” Return Air-intake Choices Bottom Back Standard Features l Dry Mode Weekly Timer Sleep Timer* 24-Hour Timer* Minimum Heat Mode* Auto Mode Quiet Mode Auto Restart/Reset Auto Changeover Condensate Pump Fresh Air Intake l l l l l l 22-19/32 (574) 30-15/32 (774) 38-11/32 (974) l l l 3/4 (19) (Flat) 3/4 (19) (Flat) 3/4 (19) (Flat) 3/4 (19) (Flat) l R410A R410A R410A R410A *Available only with optional wireless remote control. Field Supplied Filters Used With Compact Duct Units Filters are sized to keep velocities and static pressure loss low. This will insure sufficient static pressure is available for ductwork, fittings and supply and return grilles. lternative filter sizes with equivalent face areas can be used. After deducting filter loss, available static pressure values are shown. 6 A fiberglass filter is shown in blue to the left. A MERV pleated filter is shown in white. ARU ARU ARU 24RLF 18RLF 12RLF 806 547 353 18 x 30 14 x 25 12 x 20 215 225 212 0.20 0.36 0.36 1" Fiberglass Filter 0.04 0.04 0.04 0.16 0.32 0.32 1" MERV 8 Pleated Filter 0.13 0.14 0.12 0.07 0.22 0.24 2" MERV 8 Pleated Filter 0.07 0.08 0.07 0.13 0.28 0.29 CFM Typical Filter Size Velocity, FPM Unit External SP, in. W.C. ARU 9RLF 353 12 x 20 212 0.36 SP Loss, in. W.C. Available Static Pressure 0.04 0.32 SP Loss, in. W.C. Available Static Pressure 0.12 0.24 SP Loss, in. W.C. Available Static Pressure 0.07 0.29 Compact Duct Units require field supplied filters. They can be installed at the unit or for more convenient servicing, in filter grilles. The chart to the right provides guidelines for determining filter sizes. Compact Cassettes 9, 12, and 18,000 BTUs AUU9RLF, AUU12RLF, AUU18RLF Easy Installation Fits into a standard ceiling tile*. Compact cassette and compact duct models can be networked. AUU9RLF AUU12RLF AUU18RLF 22.5” 22.5” Nominal Cooling BTU/h 20,000 318 (540) Clg or Htg 288 (490) Clg or Htg 259 (440) Clg or Htg 230 (390) Clg or Htg 359 (610) Clg or Htg 312 (530) Clg or Htg 277 (470) Clg or Htg 241 (410) Clg or Htg 441 (750) Clg 471 (800) Htg 359 (610) Clg 418 (710) Htg 306 (520) Clg 353 (600) Htg 241 (410) Clg 265 (450) Htg Noise Level dB(A) Clg/Htg: Hi 33/34 37/37 42/44 Medium 31/32 33/33 37/40 Low 29/29 31/31 33/37 Quiet 27/27 28/28 29/30 Rated (A): Cooling 0.15 0.19 0.30 Heating Medium Low 1-stage Running Current l l l l l l l l l l l l Sleep Timer Dry Mode Auto Louver: Up/ Down Quiet Mode Auto Restart/Reset Auto Changeover Remote Temperature Sensor High Ceiling Mode Condensate Pump 2-Stage Turbo Fan Minimum Heat Mode+ Fresh Air Intake** 18,000 208-230/60/1 Quiet Standard Features 12,000 13,500 2-Stage Turbo Fan Increased 20% 9,000 208-230/60/1 *Dimensions of outer grille are 27-9/16” x 27-9/16” and may overlap adjacent tiles. Heat exchange efficiency: Heat Pump 10,200 Air Circ. C.F.M. (m3/h): Hi 2-stage Heat Pump 208-230/60/1 Nominal Heating BTU/h Voltage/Frequency/Phase Air distribution is evenly spread across the heat exchanger by the new 2 stage turbo fan which produces two separate airflow streams. Heat Pump Power Use 0.15 0.19 0.30 Rated/Max (W): Clg 18 23 39 Heating 18 23 39 Fan Speeds Stage 4+auto 4+auto 4+auto Air Direction: Vertical Automatic Automatic Automatic Air Filter Washable Washable Washable UTG-CCGF* UTG-CCGF* UTG-CCGF* Front Grille Connection Method Conn. Pipe Diameter Inch Net Weight lbs. (kg) Flare Flare Flare suc 3/8 dis 1/4 suc 3/8 dis 1/4 suc 1/2 dis 1/4 33 (15) 33 (15) 33 (15) Chassis Dim: Height Inch (mm) 9-11/16 (245) 9-11/16 (245) 9-11/16 (245) Width Inch (mm) 22-7/16 (570) 22-7/16 (570) 22-7/16 (570) Depth Inch (mm) 22-7/16 (570) 22-7/16 (570) 22-7/16 (570) Grille Dim: Height Inch (mm) 1-15/16 (49) 1-15/16 (49) 1-15/16 (49) Width Inch (mm) 27-9/16 (700) 27-9/16 (700) 27-9/16 (700) Depth Inch (mm) 27-9/16 (700) 27-9/16 (700) 27-9/16 (700) R410A R410A R410A Refrigerant + Available only with optional wireless remote control. **Requires Fujitsu’s Optional Fresh Air Kit part #UTZ-VXAA. Allows for a 4 – inch flex duct connection and a field supplied duct booster fan. Fresh air maximum is 10% of unit High fan CFM. See UTZ-VXAA Design and Technical Manual for fan static pressure requirements at Fresh Air Kit. Add hood, filter and duct losses for fan total static pressure requirements. Will add 4” to the height of the indoor unit. * Compact Cassette Grille UTG-CCGF sold separately. Must order one with each compact cassette. Fresh Air Kit** UTZ-VXAA Mixes room air then passes through the heat exchanger. 7 Optional Accessories Wired Remote Controller* Simple Remote Controller Wireless Remote Controller UTY-RNNUM^ UTY-RSNUM* UTY-LNHUM The wired remote controller with its unique lock function and sleek design provides full feature access to property managers, building owners, and facility maintenance, as well as providing basic comfort features to tenants, employees, and teachers. Suitable when only basic operations are required for hotels, offices and other places where there is frequent arrival and departure of occupants. For spaces where there is just no place to mount the wired remote. Dry Contact Wire Kit* Interface Kit Interface Kit UTY-XWZX / UTY-XWZXZ5 UTY-TWBXF** UTY-XCBXZ1** Turns system on or off using a normally closed circuit, for example in home automation or BMS integration of only On/Off operation, occupancy sensor or key card switch or lead-lag control of other heating/cooling. Required to connect the ASU9RLS2, ASU12RLS2 and ASU15RLS2 to Wired Remote UTY-RNNUM, Dry Contact Wire Kit UTY-XWZXZ5, and Simple Remote Control UTY-RSNUM. Required to connect ASU7RLF, 9RLF, 12RLF and ASU15RLS to Wired Remote UTY-RNNUM, Dry Contact Wire Kit UTY-XWZX, and Simple Remote Control UTY-RSNUM. High Humidity Insulation Kit Fresh Air Intake Kit Air Outlet Shutter Plate UTZ-KXGC UTZ-VXAA UTR-YDZB Additional insulation for compact cassette units, which may be needed when they are installed in high humidity areas. Mixes room air then passes it through a heat exchanger. Receiver Unit Remote Sensor UTY-LRHUM UTY-XSZX Includes a wireless remote control. Wall mounted temperature sensor for compact duct models. In a 3-way air flow configuration an Air Outlet Shutter Plate kit is required. Compact Duct Connector Kit 18+18 Combo Fittings Kit UTD-ECS5A K9FZ1818 Comes with 5 sets of wires. Can be used to turn unit on/off, wire in float switch, AUX heater, turn on an external device (Fan), or show if the unit is running. Allows two 18,000 BTU indoor units to be used on an outdoor AOU36RLXFZ. Requires special piping; limited to only 18,000 BTU models. Total BTU capacity is limited to 35,800 BTU. Compatibility: Small Wall Mount Designer Wall Mount Large Wall Mount Compact Cassette Compact Duct 7,9,12k BTU / RLF Series 9,12, 15k BTU / RLS2 Series 18, 24k BTU 9, 12, 18k BTU 9, 12, 18, 24k BTU ^ Minimum Heat, Sleep Timer functions will be lost when the wired remote controller is installed. * Wall mounted ASU7, 9, and 12RLF require accessory interface kit (Part UTY-XCBXZ1) in order to connect this device to them. Wall mounted ASU9, 12, and 15RLS2 require accessory interface kit (Part UTY-TWBXF) in order to connect this device to them. ** Internal thermosensor function in Wired Remote UTY-RNNUM is disabled when using this interface kit. The Fujitsu logo is a registered trademark of Fujitsu Limited. The Halcyon HFI logo and name is a trademark of Fujitsu General America, Inc. Copyright © 2013 Fujitsu General America, Inc. Fujitsu’s products are subject to continuous improvements. Fujitsu reserves the right to modify product design, specifications and information in this brochure without notice and without incurring any obligations. PLEASE NOTE: Internet sales are strictly prohibited and unauthorized. Any HVAC systems purchased on the Internet, from an online retailer or any similar e-tailing website, OR where the original factory serial numbers of the display have been removed, defaced, or replaced in any way WILL NOT BE COVERED BY WARRANTY. Fujitsu General America, Inc. 353 Route 46 West Fairfield, NJ 07004 Toll Free: (888) 888-3424 Local: (973) 575-0380 Fax: (973) 836-0447 Email: hvac@fujitsugeneral.com www.fujitsugeneral.com A subsidiary of Printed in the USA Rev. 3/13 Part #6-26-FG2038 Fujitsu General Limited
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 8.1.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2013:03:12 10:20:13-04:00 Create Date : 2013:03:12 10:20:13-04:00 Format : application/pdf Title : HFI_Multi_Brochure_1-2013_Layout 1 Creator : emezle Document ID : uuid:009ce10e-6898-43d2-b009-1baf96e2d46a Instance ID : uuid:9f13f6b2-6239-4fe8-a130-e625203d948e Page Count : 8 Author : emezleEXIF Metadata provided by EXIF.tools