Furuno USA 9ZWRTR092A Marine Radar User Manual
Furuno USA Inc Marine Radar
users manual
Installation Manual RADAR SENSOR DRS2D/DRS4D/ DRS4A/DRS6A/DRS12A/DRS25A SAFETY INSTRUCTIONS ............................................................................ i SYSTEM CONFIGURATION ....................................................................... ii EQUIPMENT LISTS.................................................................................... iv 1. MOUNTING ............................................................................................ 1 1.1 1.2 1.3 1.4 Mounting Considerations ..............................................................................................1 Mounting Procedure for DRS2D/4D ............................................................................. 2 Mounting Procedure for DRS4A/6A/12A/25A ...............................................................3 Mounting of Power Supply Unit PSU-013 (for DRS25A)/PSU-012 (Option) ................8 2. WIRING .................................................................................................. 9 2.1 2.2 2.3 2.4 Wiring inside DRS2D/4D ............................................................................................12 Wiring inside DRS4A/6A/12A/25A ..............................................................................16 Wiring inside Power Supply Unit PSU-013 (for DRS25A) .......................................... 20 Wiring inside Power Supply Unit PSU-012 (Option)................................................... 21 PACKING LISTS...................................................................................... A-1 OUTLINE DRAWINGS............................................................................. D-1 INTERCONNECTION DIAGRAMS.......................................................... S-1 www.furuno.co.jp SAFETY INSTRUCTIONS WARNING WARNING Do not open the equipment unless totally familiar with electrical circuits and service manual. Radio Frequency Radiation Hazard The radar antenna emits electromagnetic radio frequency (RF) energy which can be harmful, particularly to your eyes. Never look directly into the antenna aperture from a close distance while the radar is in operation or expose yourself to the transmitting antenna at a close distance. Only qualified personnel should work inside the equipment. Wear a safety belt and hard hat when working on the antenna unit. Serious injury or death can result if someone falls from the radar mast. Distances at which RF radiation levels of 100 and 10 W/m2 exist are given in the table below. Construct a suitable service platform from which to install the antenna unit. Note: If the antenna unit is installed at a close distance in front of the wheel house, your administration may require halt of transmission within a certain sector of antenna revolution. This is possible Ask your FURUNO representive or dealer to provide this feature. Serious injury or death can result if the power is left on or is applied while the equipment is being installed. Turn off the power at the mains switch-board before beginning the installation. Model DRS4A DRS6A DRS12A (XN12A) DRS12A (XN13A) DRS25A (XN12A) DRS25A (XN13A) DRS2D DRS4D Fire, electrical shock or serious injury can result if the power is left on or is applied while the equipment is being installed. CAUTION Ground the equipment to prevent electrical shock and mutual interference. Observe the following compass safe distance to prevent deviation of a ma gnetic compass. Model DRS4A DRS6A DRS12A DRS25A DRS2D DRS4D PSU-012 PSU-013 Standard Steering 0.80 m 0.85 m 1.15 m 1.00 m 1.35 m 1.40 m 0.50 m 0.55 m 0.70 m 0.60 m 0.80 m 0.85 m 0.30 m 0.30 m 0.30 m 0.30 m Distance to Distance to 100 W/m2 point 10 W/m2 point 1.20 m Nil 1.20 m Nil 0.20 m 2.40 m 1.90 m 0.20 m 0.50 m 5.30 m 4.40 m 0.40 m 0.40 m Nil 0.10 m 1.40 m SYSTEM CONFIGURATION DRS2D/4D/4A/6A/12A RADAR SENSOR DRS2D/DRS4D RADAR SENSOR DRS4A/DRS6A/DRS12A NMEA 2000 Equipment NMEA 2000 Equipment Power Supply Unit PSU-012* 12-24 VDC OR Multi Function Display BlackBox MFDBB Multi Function Display MFD8/12 : Standard Supply : Optional Supply RECTIFIER RU-1746B 12-24 VDC : Local Supply 100/110/220/230 VAC *The power supply unit PSU-012 is necessary in the combination of radar sensor and MFD. DRS2D/4D DRS4A DRS6A MFD8 NO YES YES YES MFD12 NO NO NO YES MFDBB NO NO NO NO ii DRS12A (future development) DRS25A RADAR SENSOR DRS25A NMEA 2000 Equipment Power Supply Unit PSU-013 12-24 VDC Multi Function Display BlackBox MFDBB OR Multi Function Display MFD8/12 RECTIFIER RU-1746B : Standard Supply : Optional Supply : Local Supply 12-24 VDC iii 100/110/220/230 VAC EQUIPMENT LISTS Standard supply Name Radar Sensor Type XN10A-RSB-118-092 Code No. Qty For DRS4A, w/CP03-32601 For DRS6A, w/CP03-32601 For DRS12A, 1255 mm, w/CP03-32601 For DRS12A, 1795 mm, w/CP03-32601 XN12A-RSB-118-093 XN12A-RSB-118-094 XN13A-RSB-118-094 Remarks XN12A-RSB-118-095 For DRS25A, 1255 mm, w/CP0332601 XN13A-RSB-118-095 For DRS25A, 1795 mm, w/CP0332601 DRS2D Radome, 2 kW, w/CP03-32101 DRS4D Radome, 4 kW, w/CP03-32101 Power Supply Unit PSU-013 For DRS25A, w/SP03-16101 and CP03-32700 Installation Materials CP03-32101 001-025-270 1 set For DRS2D/4D CP03-32601 001-025-780 1 set For DRS4A/6A/12A/25A CP03-32200 000-011-720 CP03-32300 000-011-721 Two-way cable, MOD-ASW0001150+, 15 m, for DRS2D/4D/4A/6A/12A CP03-32400 000-011-722 Two-way cable, MOD-ASW0001200+, 20 m, for DRS2D/4D/4A/6A/12A CP03-32500 000-011-723 Two-way cable, MOD-ASW0001300+, 30 m, for DRS2D/4D/4A/6A/12A CP03-32800 000-011-990 Two-way cable, MOD-ASW0002100+, 10 m, for DRS25A CP03-32810 000-011-991 Two-way cable, MOD-ASW0002150+, 15 m, for DRS25A CP03-32820 000-011-992 Two-way cable, MOD-ASW0002200+, 20 m, for DRS25A CP03-32830 000-011-993 Two-way cable, MOD-ASW0002300+, 30 m, for DRS25A iv Two-way cable, MOD-ASW0001100+, 10 m, for DRS2D/4D/4A/6A/12A Optional supply Name Type Code No. Qty 1 set Remarks Power Supply Unit PSU-012 Gasket OP03-203 001-025-290 OP03-205 001-025-790 For DRS4A/6A, Ď10 NMEA2000 cable OP03-206 001-035-290 For DRS25A, Ď10 NMEA2000 cable Resister Assy OP03-204 001-025-300 For NMEA2000 connection with a unit Joint Box TL-CAT-012 000-167-140-10 For LAN cable extension LAN Cable MOD-Z072-020+ 000-167-175-10 2m MOD-Z072-050+ 000-167-176-10 5m MOD-Z072-100+ 000-167-177-10 10 m M12-05BFFM-010 000-167-965-10 NMEA2000, Ď6, w/connector, 1 m M12-05BFFM-020 000-167-966-10 NMEA2000, Ď6, w/connector, 2 m M12-05BFFM-060 000-167-967-10 NMEA2000, Ď6, w/connector, 6 m CB-05BFFM-010 000-167-971-10 NMEA2000, Ď10, w/connector, 1 m CB-05BFFM-020 000-167-972-10 NMEA2000, Ď10, w/connector, 2 m CB-05BFFM-060 000-167-973-10 NMEA2000, Ď10, w/connector, 6 m Cable Assy For DRS2D/4D, Ď10 NMEA2000 cable 1. MOUNTING 1.1 Mounting Considerations ⢠The radar sensor is generally installed either on top of the wheelhouse or on the radar mast on a suitable platform. Locate the radar sensor where there is a good all-round view. Any obstruction will cause shadow and blind sectors. A mast for instance, with a diameter considerably less than the horizontal beamwidth of the radiator, will cause only a small blind sector, but a horizontal spreader or crosstrees in the same horizontal plane as the radar sensor would be a much more serious obstruction; you would need to place the radar sensor well above or below it. ⢠It is rarely possible to place the radar sensor where a completely clear view in all directions is available. Thus, you should determine the angular width and relative bearing of any shadow sectors for their influence on the radar at the first opportunity after fitting. ⢠A magnetic compass will be affected if the radar sensor is placed too close to it. Observe the compass safe distances mentioned in the SAFETY INSTRUCTIONS to prevent interference to a magnetic compass. ⢠Do not paint the radiator aperture and radome to ensure proper emision of the radar waves. ⢠When this radar sensor is to be installed on large vessels, consider the following points: ⢠The two-way cable run between the radar sensor and MFDBB, MFD8, MFD12 or PSU-012 comes in lengths of 10 m, 15 m, 20 m or 30 m. ⢠Deposits and fumes from a funnel or other exhaust vent can adversely affect the aerial performance and hot gases may distort the radiator portion. The radar sensor must not be mounted where the temperature is more than 55 degrees centigrade. As shown in the figure below, the radar sensor may be installed on a common mast or on the radar mast. (b) Radar mast (a) Common mast For DRS4A/6A/12A Radar sensor Radar sensor Radar sensor Radar sensor For DRS2D/4D 1.2 Mounting Procedure for DRS2D/4D 1. Remove mounting hardware at the bottom of the radar sensor, four each of hex bolts (M10x20), spring washers and flat washers. Save the spring washers and flat washers to use them to fix the radome base to the platform, at step 3. If the thickness of the mounting platform is 5 mm or less, also save the bolts. Screws (two screws on other side) Stern Cable entry Bow Flat washer Spring washer Hex bolt (M10 x 20) 2. Construct a platform (steel or aluminum) 6-10 mm in thickness referring to the outline drawing at the back of this manual. Fasten the platform to the mounting location. Next, position the base so the cable entrance is facing the stern. Note: When drilling holes in the platform, be sure they are parallel with the fore and aft line. 3. Use the hex bolts*, flat washers and spring washers removed at step 1, and fasten the radome base to the platform. The torque should be between 19.6-24.5Nzm. *If the thickness of the platform is 6-10 mm, use M10x25 bolts (supplied). For thicker platform, use locally supplied bolts. Transceiver module Flat washer Spring washer Antenna base assy. 5 mm or under: M10x20 (local supply) 6-10 mm: M10x25 (supplied) over 10 mm: locally supplied bolts As for length, use the bolt the "L" shown in the figure in left becomes 10 to 15 mm. Platform Hex bolt Apply silicone sealant. (M10 x 25 or M10 x 20) 4. Mount the cover tentatively. The cover is opened for wiring at Chapter 2. 1.3 Mounting Procedure for DRS4A/6A/12A/25A Refer to the outline drawing at the back of this manual, and drill five holes in the mounting platform: four holes of 15 mm in diameter for fixing the radar sensor and one hole of 25-30 mm in diameter for the signal cable. The outline drawing shows two cable entrance holes, one on the radar sensor and one on the rubber mat. Use only the one on the rubber mat. 1.3.1 Fastening the radiator to the radiator bracket 1. Remove the radiator cap from the radiator bracket. 2. Coat the surface of the radiator bracket with silicone sealant as shown in the figure below. RADIATOR BRACKET (top view) 10mm (Do not coat.) Coat hatched area with silicone sealant. 3. Coat threaded holes on the antenna radiator with silicone sealant. 4. Grease the O-ring and set it to the radiator bracket. 5. Coat the hex bolts (4 pcs.) with silicone sealant. Fasten the antenna radiator to the radiator bracket with the hex bolts, flat washers and spring washers supplied with the radiator Then, apply silicone sealant around the junction part between the radiator and bracket. 6. Apply silicone sealant to holes to prevent water ingress. Antenna radiator Radiator bracket, bottom view O-ring Radiator bracket Flat washer Spring washer Hex bolt (M8 x 30) 1.3.2 Coat threaded holes with silicone sealant. Coat bolts with silicone sealant. Apply silicone sealant around the joint part with the antenna radiator. (four): Holes where to apply silicone sealant. Mounting the radar sensor The radar sensor can be mounted using the fixing holes on the outside (200 x 200 mm) or inside (140 x 150 mm) the radar sensor. Using outside fixing holes of radar sensor Use the hex bolts (supplied) to mount the radar sensor as below. 1. Lay the corrosion-proof rubber mat (supplied) on the mounting platform. Rubber mat Ground terminal Bow mark 2. Lay the radar sensor on the mounting platform, orienting it as shown below. (The hinges must face toward the stern.) BOW STERN Hinge CAUTION Do not lift the radar sensor by the radiator; lift it by the housing. The radiator may be damaged. 3. Insert four hex bolts (M12 x 60, supplied) and seal washers (Ď30, supplied) from the top of the housing, as shown below. Hex. bolt Seal washer (Face projecting part down.) Flat washer Spring washer Nut 4. Pass flat washers (M12, supplied), spring washers (M12, supplied) and nuts (M12, supplied) onto hex. bolts. Fasten by tightening nuts. Do not fasten by tightening the hex. bolts; seal washers may be damaged. Seal washer Antenna unit Mounting platform Silicone sealant Rubber mat Flat washer 5. Coat flat washers, spring washers, nuts and exposed parts of bolts with anticorrosive sealant. 6. Prepare ground point in mounting platform (within 300 mm of ground terminal on radar sensor) using M6 x 25 bolt, nut and flat washer (supplied). 7. Run the ground wire (RW-4747, 340 mm, supplied) between the ground terminal and ground point. 8. Coat ground terminal and ground point with silicone sealant as shown below. Hex. bolt Flat washer Ground wire Silicone sealant Flat washer Spring washer Hex. nut OR GROUND POINT Hex. nut Spring washer Flat washer Hex. nut Ground wire Weld here. GROUND TERMINAL Silicone sealant Ground wire antenna unit Using inside fixing holes of the sensor housing If this radar is replacing a FURUNO radar whose mounting dimensions are the same as this one (140 x 150 mm), it may be possible to use its mounting platform. This method requires removal of the RF unit from the radar sensor to access inside fixing holes. Use hex bolts, flat washers, spring washers and nuts (local supply) to mount the radar sensor. 1. Unfasten four bolts from the cover to open the radar sensor. 2. Unplug the PCS connector from RF unit. 3. Separate upper chassis from lower chassis by removing two bolts (M8x25). 4. Remove RF unit by unfastening two hex bolts and two fixing bolt. Upper chassis Bolt M8x25, 2 pcs. RF unit PCS connector Hex bolt 2 pcs. Fixing bolt (2 pcs.) Inside fixing holes Lower chassis (Example: DRS4A/6A) For DRS12A/25A, unfasten four hex bolts, not two fixing bolts, to remove the RF unit. 5. Lay the corrosion-proof rubber mat (supplied) on the mounting platform. 6. Fasten the lower chassis to the mounting platform with hex bolts, spring washers, flat washers and nuts (local supply), and then coat flat washers, nuts and exposed parts of bolts with silicone sealant. Cut a slit in the rubber bushing and insert bolt into the bushing. Do not use seal washers. 7. Remount RF unit. 8. Coat outside fixing holes with silicone sealant and then attach caps (supplied) to holes. 9. Do steps 6-8 on page 6. 1.4 Mounting of Power Supply Unit PSU-013 (for DRS25A)/PSU-012 (Option) For combinations shown below, the optional power supply unit PSU-012 (Code No.: 000-011-756) is necessary. The PSU-013 is required for any DRS25A installation. DRS2D/4D DRS4A DRS6A DRS12A MFD8 NO YES YES YES MFD12 NO NO NO YES MFDBB NO NO NO NO Contents of PSU-0012/013 Name Type Power supply unit Code No. PSU-012 PSU-013 Qty Remarks for DRS25A Cable assy VL3P-VV-S2X2C-AA050 000-152-217-10 5m LAN cable MOD-Z072-050+ 000-167-176-10 5 m, standard Self-tapping screw 4x20, SUS304 000-158-850-10 Fuse* FGB0 250V 10A 000-155-839-10 For 24 VDC FGB0 250V 15A 000-157-874-10 For 12 VDC *Note: The power supply unit is shipped with 15A fuse. Replace fuse with 10A when using the unit with 24V shipâs battery. The power supply unit can be installed almost anywhere provided the following conditions are met: ⢠Location is dry, well ventilated. ⢠Sufficient maintenance space is available. ⢠Installated within 2, 5 or 10 m (2 and 10 m: optional supply) from the multi function display. Do not install the power supply unit on the overhead; install it on the deck or bulkhead. Use four tapping screws (4x20, supplied) to fasten the power supply unit. Self-tapping screw (4x20, 4 pcs.) Power supply unit PSU-012/013 2. WIRING The MFDBB, MFD8, MFD12 or PSU-012 connects to the radar sensor with the two-way cable MOD-ASW0001 (MOD-ASW0002 for DRS25A).In order to minimize the chance of picking up electrical interference, avoid where possible routing the two-way cable near other onboard electrical equipment. After passing the cable through the hole in the radar sensor, apply sealing compound around the hole for waterproofing. When connecting to other NMEA2000 equipment, use the optional cable M12-05BFFM (Ď6) or CB-05BFFM (Ď10). NOTICE Before connecting or disconnecting the NMEA2000 cable, turn off the radar sensor. The sensor may become damaged if the power is not turned off. Wiring for DRS2D/4D/4A/6A/12A without PSU-012 RADAR SENSOR DRS2D/DRS4D RADAR SENSOR DRS4A/DRS6A/DRS12A NMEA2000 cable M12-05BFFM (Ď6) or CB-05BFFM (Ď10) Two-way cable MOD-ASW0001 (10/15/20/30 m) NMEA2000 Equipment NMEA2000 Equipment NMEA2000 cable M12-05BFFM (Ď6) or CB-05BFFM (Ď10) : Standard Supply : Optional Supply To Multi Function Display BlackBox MFDBB or Multi Function Display MFD8/12 Wiring for DRS2D/4D/4A/6A/12A with PSU-012 Radar Sensor DRS2D/DRS4D Radar Sensor DRS4A/DRS6A/DRS12A NMEA2000 cable M12-05BFFM (f6) or CB-05BFFM (f10) Two-way cable MOD-ASW0001 (10/15/20/30 m) NMEA2000 Equipment NMEA2000 cable M12-05BFFM (f6) or CB-05BFFM (f10) (LAN) NMEA2000 Equipment (Power) Power Supply Unit PSU-012 12-24 VDC Power cable VL3P-VV-S2X2C-AA050 (supplied with PSU-012) : Standard Supply LAN cable MOD-Z072 -5 m: supplied -2, 10 m: option To ship's ground : Optional Supply : Local Supply Ground wire (Local supply, IV-2sq) To Multi Function Display BlackBox MFDBB or Multi Function Display MFD8/12 Wiring for DRS25A RADAR SENSOR DRS25A NMEA2000 cable M12-05BFFM (f6) or CB-05BFFM (f10) Two-way cable MOD-ASW0002 cable (10/15/20/30 m) NMEA2000 Equipment (POWER) (LAN) Power cable VL3P-VV-S2X2C-AA50 Power Supply Unit PSU-013 12-24 VDC Ground wire (Local supply, IV-2sq) To ship's ground LAN cable MOD-2072-050 : Standard Supply To Multi Function Display BlackBox MFDBB or Multi Function Display MFD8/12 10 : Optional Supply : Local Supply How to terminate of NMEA2000 connection When connecting the radar sensor and an NMEA2000 equipment using the optional cable M1205BFFM (Ď6) or CB-05BFFM (Ď10), attach the terminator (supplied as installation materials) to the NMEA connector in the radar sensor. 1. Twist the lead wire of the resistor assembly to the cable M12-05BFFM (Ď6) or CB-05BFFM (Ď10), and solder them as below. Resistor assembly (120 OHM-1007#24-L150) White Twisting and soldering Blue NMEA2000 cable 2. Connect wires to the NMEA connector consulting the label on the connector. NMEA2000 connector (in the sensor) Note: This fabrication is not necessary when the external terminators are attached as below. NMEA2000 equipment or DRS2D/DRS4D External terminator 1 DRS4A/DRS6A/DRS12A Backbone cable 11 External terminator 2 2.1 Wiring inside DRS2D/4D Two-way cable connection 1. Unfasten three screws at the bottom of the mounting base to remove the fixing plate for the gasket. Fixing plate (for gasket) 2. Remove the gasket, and pass the two-way cable MOD-ASW0001. 3. Fasten the shield of the cable (power) with the cable clamp in the radar sensor, and connect the connector of cable (power) to the power terminal. 4. Connect the RJ-45 connector of the cable (LAN) to the LAN terminal in the radar sensor. LAN terminal Power terminal Fix the cable (LAN) with this locking saddle. Fix the shield cable (power) with this clamp. 5. Push cables of the two-way cable into the slits of the gasket inside the radar sensor. Note: The ends of the gasket are different. Larger end should be up. Large Up Small 12 6. Slide the gasket on cables so that the amount of cable above the gasket is lower than the RF chassis. This height should be lower than the RF unit when installed to the bottom of the sensor. Gasket Cable RF unit Gasket Note: If the two-way cable touches the platform near the mounting base, wind vinyl tape around the cable at the point where it is bent. 7. Confirm that the rubber gasket is properly positioned and that the triangle mark on the cover is aligned with the triangle mark on the mounting base, then tighten the fixing screws for the cover. Triangle marks Cover Mounting base Connecting to NMEA2000 equipment To connect NMEA2000 equipment to the sensor, wire an optional NMEA2000 cable, M12-05BFFM (Ď6) or CB-05BFFM (Ď10), as shown below. Also, the gasket at the bottom of mounting base must be replaced. 1. Do steps 1 to 4 on page 12. 2. Refer to the figure below, and fabricate the cable M12-05BFFM (Ď6) or CB-05BFFM (Ď10). 15 (Area fastened with the cable clamp) M12-05BFFM cable 100 Shield Fabrication of cable M12-05BFFM (Ď6) 13 5 15 Shield CB-05BFFM cable 370 Wind vinyl tape. (supplied) Fasten the cable tie (supplied) within 15 mm from the end of vinyl sheath. CB-05BFFM cable 20 65 15 (Area fastened with the cable clamp) Fabrication of CB-05BFFM cable 3. Insert wires of cable M12-05BFFM (Ď6) or CB-05BFFM (Ď10) to the NMEA connector inside the radar sensor, consulting the label on the connector for location. As for shield, use the cable clamp shown below. Cable Clamp M12-05BFFM (Ď6) CB-05BFFM (Ď10) Use the clamp pre-attached inside the radar Use the clamp supplied with the optional gasket sensor. (Type: OP03-203, Code No.: 001-025-290) Zoom up Location of the cable clamp Attach the cable clamp using this screw for CB05BFFM cable. (Face projecting part down.) Cable clamp 14 4. Push LAN and POWER cables of the two-way cable and cable M12-05BFFM (Ď6) or CB05BFFM (Ď10) into the slits of the gasket inside the mounting base. Depending on the NMEA2000 cable used, replace the gasket as shown below. Cable type Gasket M12-05BFFM (Ď6) CB-05BFFM (Ď10) Use the gasket supplied in the plastic bag inside the radar sensor. Use the optional gasket. (Type: OP03-203, Code No.: 001-025-290) Note: The ends of the gasket are different. Larger end should be up) Large Up Small 5. Slide the gasket on cables so that the amount of cable above the gasket is lower than the RF chassis. This height should be lower than the RF unit when attaching to the bottom of the sensor. Gasket RF unit Cable RF unit Gasket Note: If the two-way cable touches the platform near the radar sensor base, wind vinyl tape around the cable at the point where is bent. 6. Confirm that the rubber gasket is properly positioned and that the triangle mark on the cover is aligned with the triangle mark on the mounting base, then tighten the fixing screws for the cover. 15 2.2 Wiring inside DRS4A/6A/12A/25A Two-way cable connection If you have no NMEA2000 equipment to connect, use the MOD-ASW0001 cable (standard supply). 1. Open the radar sensor cover by loosening four bolts, and fix the stay for safety purpose. 2. Unfasten four bolts to detach the plate, gasket, washer and lid. Discard the lid at the bottom of the hole for the gasket. Plate Gasket Washer Lid Stay 3. Pass the two-way cable MOD-ASW0001 (MOD-ASW0002 for DRS25A) through the bottom of the chassis and washer. 4. Fasten the shield of the power cable of the two-way cable (part of the foil) with the cable clamp in the radar sensor, and then connect the power cable to the power terminal as shown on next page. 16 5. Attach the LAN cable of the two-way cable to the LAN terminal in the radar sensor. Fix the power cable at the foil part with this cable clamp. Power cable White Power terminal Black LAN cable RF unit LAN terminal DRS4A/6A/12A Fix the power cable at the copper foil part with this cable clamp. Gasket LAN cable White Power terminal Blue Red Power cable Black LAN terminal DRS25A 6. Refer to the illustration shown below, and attach the gasket to the two-way cable, inserting the cable into the slits on the gasket. 17 7. Slide the gasket on cables so that the amount of cable above the gasket is lower than the RF chassis. This height should be lower than the RF unit when installed to the bottom of the sensor. Cable RF unit Gasket Gasket Washers 8. Push the gasket and washers into the hole at the bottom of the radar sensor, then fasten four pan head screws to fix the plate to the sensor. 9. Release the stay and close the cover. Note: When closing the cover, set the gaskets to grooves in the bottom chassis, then tighten bolts. BOTTOM CHASSIS GROOVE Torque : 9.8 Âą0.1 N . m GASKET HEX BOLT Connecting to NMEA2000 equipment To connect NMEA2000 equipment to the sensor, use an optional NMEA2000 cable, M12-05BFFM (Ď6) or CB-05BFFM (Ď10). Also, the gasket at the bottom of the antenna sensor must be replaced. 1. Do steps 1 to 5 on pages 16 and 17. 2. Fabricate the cable M12-05BFFM (Ď6) or CB-05BFFM (Ď10) as shown below. 95 Cable M12-05BFFM or CB-05BFFM Drain wire 3. Pass the cable through the bottom of the chassis. 4. Insert wires of the cable M12-05BFFM (Ď6) or CB-05BFFM (Ď10) to the NMEA connector inside the radar sensor, consulting the label on the connector for location. As for drain wire, attach 18 the crimp-on lug (pre-attached at the bottom of the chassis) to the drain wire, and fasten it with the screw shown below. NMEA connector view NMEA connector Crimp-on lug Drain wire Fasten the drain wire with this screw. NMEA cable RF unit 5. Depending on the NMEA2000 used, replace the gasket as shown below. DRS4A/6A/12A Cable type Gasket M12-05BFFM (Ď6) CB-05BFFM (Ď10) Use the gasket supplied in the plastic bag inside the radar sensor. Use the optional gasket. (Type: OP03-205, Code No.: 001-025-790) DRS25A Cable type Gasket M12-05BFFM (Ď6) CB-05BFFM (Ď10) Use the gasket supplied in the plastic bag inside the radar sensor. Use the optional gasket. (Type: OP03-206, Code No.: 001-035-290) 6. Refer to the illustration shown on next page, and attach the gasket to the two-way cable inserting the cable into the slits on the gasket. 7. Slide the gasket on cables so that the amount of cable above the gasket is lower than the RF chassis. This height should be lower than the RF unit when installed to the bottom of the sensor. Cable Gasket RF unit Washer 8. Do steps 8 and 9 on page 18. 19 Gasket 2.3 Wiring of Power Supply Unit PSU-013 (for DRS25A) 1. Detach the body cover by hand. 2. Loosen six pan head screws (M3x8) and slide the shield cover upward to remove it. 3. Unfasten four pan head screws (M14x10) to remove two cable clamps. Body cover Shield cover Pan head screws (M4x10, 4 pcs.) Cable clamps Pan head screws (M3x8, 6 pcs.) 4. Connect the cable VL3P-VV-S2X2C-AA50 and MOD-ASW0002 cables (supplied) to appropriate connectors in the power supply unit as shown below. 1: Red 2: N. C. White Black 1: White 2: Black 3: Blue VL3P-VV-S2X2C-AA50 cable MOD-ASW0002 cable (Power) 5. Remove two cable clamps, shield cover and body cover in that order. 6. Connect other cables. 20 2.4 Wiring inside Power Supply Unit PSU-012 (Option) 1. Detach the body cover by hand. 2. Loosen six pan head screws (M3x8) and slide the shield cover upward to remove it. 3. Unfasten two pan head screws (M4x12) to remove the cable clamp. Body cover Shield cover Pan head screw (M4x12, 2 pcs.) Cable clamp Pan head screw (M3x8, 6 pcs.) 4. Connect the cable VL3P-VV-S2X2C-AA050 (supplied) to the power connector in the PSU012. For white wire For black wire Put the cable VL3P-VV-S2X2C-AA050 here at the shield part. 5. Remount the cable clamp, shield cover and body cover in that order. 6. Connect other cables. 21 *':$1.6 5.166'& *'#& ŕąâˇşăŠăŠ˘ăŠŚăŠ˘ăŠăŠ¨ăŠŁăŠ 524+0)9#5*'4 ăŠăŠ¨ăŠáłă (.#69#5*'4 ăŠăŠăŠ¨ăŠááłă 4'5+5614#55'/$.; ăŠă¨źăŠă¨˝âľŕş ฏâŤŢŢâŹâ 0#/' %1&' 01 /:575 %1&' 01 /575âŤŢ⏠%1&' 01 /575 /575 /575 %1&' 01 1*/. 㧲ă¨ă§žă¨ă§şă§ťâŤŢâŹă§ąă§¸ă§ąă§Żă¨ă§žă§ľă§ŻâŤŢâŹă§Żă§ťâŤŢâŹă§ă§ă§¸ă¨ă§° ă§âŕżßŠá¸á´şßŞâŤŢâŹŕˇłâ ¨ŕŻß˘ßâŤ&ŢŢâŹ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧠*#: áłáźăŠă¨şăŠăŠ¨âภßă§á˛ßŠáวâŤŢâŹŕ¨ á˛ŕ ŕ ŕ¨á˛ßŚŕŞŕ ŕ ăᡰጟຠߢ޽ŕ âŤŢß ßĽŢŢßߚ޿ߥßŕąßßŕ ßߤŢâŹŕş ➰ߪáŕ ŕ ßšß ŕ âŤŢ⏠6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4 241&7%637#.+6;+56*'5#/' âภ01 524+0)9#5*'4 ăŠăŠ¨ăŠáłă *':#)10#.076 ŕąâˇşăŠă¨šăŠăŠă¨ˇ *':#)10*'#&5%4'9 ŕąâˇşăŠăŠ¨ăŠŁăŠă§ŕąăŠăŠăŠ¨ă§ *':#)10#.076 ŕąâˇşăŠă¨šăŠăŠă¨ˇ (.#69#5*'4 ăŠăŠăŠ¨ăŠăŠăŠŁááłă 524+0)9#5*'4 ăŠăŠ¨ăŠáłă 4'5+5614#55'/$.; ăŠă¨źăŠă¨˝âľŕş -01$%#2 ăŠă¨śă¨šăŠăŠŠ %14415+102411( 47$$'4/#6 ăâ˛ŕ §ŕĄ 5'#.9#5*'4 ăŠă¨şăŠŁăŠŚă¨šăŠă¨śă¨ş ฏâŤŢŢâŹâ 0#/' ââŤŢŢâŹŕż 176.+0' 45$ áłŕ¸Źă§âˇáŠ° &'5%4+26+105 %2 %1&'01 /575 %1&'01 /575 %1&'01 /:575 %1&'01 /575 %1&'01 /575 %1&'01 /575 %1&'01 1*/. %1&'01 %1&'01 41*5 %1&'01 41*5 6;2' %1&'01 á˘ă 3 6; âŞă ă§ŕŽťâ ¨ 4'/#4-5 );: A-2 㧲ă¨ă§žă¨ă§şă§ťâŤŢâŹă§ąă§¸ă§ąă§Żă¨ă§žă§ľă§ŻâŤŢâŹă§Żă§ťâŤŢâŹă§ă§ă§¸ă¨ă§° ă§âŕżßŠá¸á´şßŞâŤŢâŹŕˇłâ ¨ŕŻß˘ßâŤ&ŢŢâŹ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧠);: 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 37#.+6;+56*'5#/' áłáźăŠă¨şăŠăŠ¨âภßă§á˛ßŠáวâŤŢâŹŕ¨ á˛ŕ ŕ ŕ¨á˛ßŚŕŞŕ ŕ ăᡰጟຠߢ޽ŕ âŤŢß ßĽŢŢßߚ޿ߥßŕąßßŕ ßߤŢâŹŕş ➰ߪáŕ ŕ ßšßŕ âŤŢ⏠âภ01 +056#..#6+10/#6'4+#.5 âŞă ă§ŕŽťâ ¨ 4'/#4-5 +056#..#6+10/#6'4+#.5 á˘ă 3 6; *#: áżŕŠá§á˘ąâ´Ť áłŕ¸Źă§âˇáŠ° &'5%4+26+105 %2 6;2' áżŕŠá§á˘ąâ´Ť ââŤŢŢâŹŕż 176.+0' %1&'01 A-1 á˘ă 3 6; âŞă ă§ŕŽťâ ¨ 4'/#4-5 %#$.'#55; ăŠă¨şăŠăŠ¨ăŠŁâľŕş %#$.'#55; ăŠă¨şăŠăŠ¨ăŠŁâľŕş %#$.'#55; ăŠă¨şăŠăŠ¨ăŠŁâľŕş %#$.'#55; ăŠă¨şăŠăŠ¨ăŠŁâľŕş ฏâŤŢŢâŹâ 0#/' ââŤŢŢâŹŕż 176.+0' %1&'01 /1; %1&'01 /1; %1&'01 /1; /1; áłŕ¸Źă§âˇáŠ° &'5%4+26+105 %1&'01 ᎥḰߪă¨ß˘Ţ˝ŕ ßá âˇßŚŕ ŕ ăŹáŻŕ¸ 56#0&.'0)6*+5/16*'4.'0)6*5#4'#.51#8#+.#$.' âภ01 &45&&&45### á˘ă 3 6; ăŹáŻâŤŢâŹ61$' 5'.'%6'& ăŹáŻâŤŢâŹ61$' 5'.'%6'& ăŹáŻâŤŢâŹ61$' 5'.'%6'& ăŹáŻâŤŢâŹ61$' 5'.'%6'& âŞă ă§ŕŽťâ ¨ 4'/#4-5 *#: 㧲ă¨ă§žă¨ă§şă§ťâŤŢâŹă§ąă§¸ă§ąă§Żă¨ă§žă§ľă§ŻâŤŢâŹă§Żă§ťâŤŢâŹă§ă§ă§¸ă¨ă§° ă§âŕżßŠá¸á´şßŞâŤŢâŹŕˇłâ ¨ŕŻß˘ßâŤ&ŢŢâŹ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧠);: 㧲ă¨ă§žă¨ă§şă§ťâŤŢâŹă§ąă§¸ă§ąă§Żă¨ă§žă§ľă§ŻâŤŢâŹă§Żă§ťâŤŢâŹă§ă§ă§¸ă¨ă§° ă§âŕżßŠá¸á´şßŞâŤŢâŹŕˇłâ ¨ŕŻß˘ßâŤ&ŢŢâŹ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧠*#: 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 37#.+6;+56*'5#/' %1&'01 49 49 %1&'01 /:575 %1&'01 /575 áłŕ¸Źă§âˇáŠ° &'5%4+26+105 +056#..#6+10/#6'4+#.5 áżŕŠá§á˘ąâ´Ť 4#5'0514 %1&'01 6;2' áłáźăŠă¨şăŠăŠ¨âภßă§á˛ßŠáวâŤŢâŹŕ¨ á˛ŕ ŕ ŕ¨á˛ßŚŕŞŕ ŕ ăᡰጟຠߢ޽ŕ âŤŢß ßĽŢŢßߚ޿ߥßŕąßßŕ ßߤŢâŹŕş ➰ߪáŕ ŕ ßšßŕ âŤŢ⏠ââŤŢŢâŹŕż 176.+0' );: A-4 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 37#.+6;+56*'5#/' %#$.'#55; ăŠă¨şăŠăŠ¨ăŠŁâľŕş *':#)10#.*'#&$1.6 ŕąâˇşăŠăŠ¨ăŠŁăŠ (.#69#5*'4 ăŠăŠăŠ¨ăŠááłă ฏâŤŢŢâŹâ 0#/' %2 6;2' A-3 áłáźăŠă¨şăŠăŠ¨âภßă§á˛ßŠáวâŤŢâŹŕ¨ á˛ŕ ŕ ŕ¨á˛ßŚŕŞŕ ŕ ăᡰጟຠߢ޽ŕ âŤŢß ßĽŢŢßߚ޿ߥßŕąßßŕ ßߤŢâŹŕş ➰ߪáŕ ŕ ßšßŕ âŤŢ⏠âภ01 +056#..#6+10/#6'4+#.5 áżŕŠá§á˘ąâ´Ť 45$ %1&'01 %#$.'#55; ăŠ@ăŠăŠ¨ăŠŁâľŕş %#$.'#55; ăŠă¨şăŠăŠ¨ăŠŁâľŕş %#$.'#55; ăŠă¨şăŠăŠ¨ăŠŁâľŕş %#$.'#55; ăŠă¨şăŠăŠ¨ăŠŁâľŕş ฏâŤŢŢâŹâ 0#/' &45# ââŤŢŢâŹŕż 176.+0' %1&' 01 /1; %1&' 01 /1; %1&' 01 /1; %1&' 01 /1; áłŕ¸Źă§âˇáŠ° &'5%4+26+105 á˘ă 3 6; ăŹáŻâŤŢâŹ61$' 5'.'%6 ăŹáŻâŤŢâŹ61$' 5'.'%6 ăŹáŻâŤŢâŹ61$' 5'.'%6 ăŹáŻâŤŢâŹ61$' 5'.'%6 âŞă ă§ŕŽťâ ¨ 4'/#4-5 *%: 㧲ă¨ă§žă¨ă§şă§ťâŤŢâŹă§ąă§¸ă§ąă§Żă¨ă§žă§ľă§ŻâŤŢâŹă§Żă§ťâŤŢâŹă§ă§ă§¸ă¨ă§° ă§âŕżßŠá¸á´şßŞâŤŢâŹŕˇłâ ¨ŕŻß˘ßâŤ&ŢŢâŹ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧠*%: áłáźăŠă¨şăŠăŠ¨âภßă§á˛ßŠáวâŤŢâŹŕ¨ á˛ŕ ŕ ŕ¨á˛ßŚŕŞŕ ŕ ăᡰጟຠߢ޽ŕ âŤŢß ßĽŢŢßߚ޿ߥßŕąßßŕ ßߤŢâŹŕş ➰ߪáŕ ŕ ßšß ŕ âŤŢ⏠6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4 241&7%637#.+6;+56*'5#/' âภ01 +056#..#6+10/#6'4+#.5 áżŕŠá§á˘ąâ´Ť 4#5'0514 %1&'01 6;2' A-5 21/Aug/09 R.Esumi D-1 22/Mar/08 R.Esumi D-2 Jan.18'08 R.Esumi D-3 D-4 2/Apr/08 R.Esumi D-5 Oct.15'07 R.Esumi C E_TD-P E_TD-N E_RD-P NC NC E_RD-N NC NC +48V GND SHIELD +48V GND SHIELD NOTE 1. SHIPYARD SUPPLY. 2. OPTION. 3. CONNECTOR PLUG FITTED AT FACTORY. ćł¨č¨ ďźďźé čšććé ă ďźďźăŞăăˇă§ăłă ďźďźăłăăŻăżăŻĺˇĽĺ ´ăŤăŚĺäťć¸ăżă MFD8/12 MFDBB(MPU-001) E_RD-P NC NC E_RD-N NC NC Ď7 RJ45 ăˇă WHT ăŻă BLK 12-24VDC VVRx2C *2 *3 MOD-Z072,2/5/10m,Ď6(CROSS) OR RJ45 MOD-WPAS0001,3m *3 MJ-A3SPF *3 RJ45 *2 MOD-WPAS0001,3m *3 MJ-A3SPF *1 DWG.No. SCALE T.TAKENO C3567-C01- B MASS kg REF.No. Ď7 ăˇă WHT ăŻă BLK J207 NETWORK E_TD-P E_TD-N E_RD-P NC NC E_RD-N NC NC DRS2D/4D 03-174-6001-1 J301 POWER 1 48V-H 2 48V-C ăžă㯠OR *3 MOD-ASW0001,Ď6 10/15/20/30m RJ45 Jan.23'08 R.Esumi Jan. 23 '08 CHECKED Jan. 23 '08 APPROVED DRAWN JUNCTION BOX RJ45 TL-CAT-012 *2 ăžă㯠OR *3 ETHERNET HUB RJ45 HUB-101 *2 J301 POWER 1 48V-H 2 48V-C ăŹăźăăź ăťăłăľăź RADAR SENSOR DRS2D/4D T.YAMASAKI J603 NMEA2000 SHIELD NC NET-S NET-C NET-H NET-L B1 RTR-090/091 *3 RJ45 J207 NETWORK 1 E_TD-P 2 E_TD-N 3 E_RD-P 4 NC 5 NC 6 E_RD-N 7 NC 8 NC FMC1.5/6ST *2 M12-05BFFM,1/2/6m CB-05BFFM,1/2/6m ă˘ăŤ RED ăŻă BLK ăˇă WHT ă˘ăŞ BLU ăăŤăăăĄăłăŻăˇă§ăłăăŁăšăăŹă¤ *3 MULTI-FUNCTION DISPLAY RJ45 MOD-ASW0001,10/15/20/30m,Ď6 MFD8/12 E_TD-P 1 MFDBB(MPU-001) E_TD-N 2 čŞćłčŁ 罎ăžăăŻăťăłăľăź NAV.EQUIPMENT OR SENSOR GP-330B SC-30 WS-200 etc. J3 1 (+) 2 (-) NAME ĺ 称 TITLE INTERCONNECTION DIAGRAM RADAR SENSOR ç¸äşçľçˇĺł DRS2D/4D ăŹăźăăźăťăłăľăź S-1 C E_TD-P E_TD-N E_RD-P NC NC E_RD-N NC NC +48V GND SHIELD +48V GND SHIELD *3 MJ-A3SPF *3 RJ45 *3 MJ-A3SPF NOTE 1. SHIPYARD SUPPLY. 2. OPTION. 3. CONNECTOR PLUG FITTED AT FACTORY. ćł¨č¨ ďźďźé čšććé ă ďźďźăŞăăˇă§ăłă ďźďźăłăăŻăżăŻĺˇĽĺ ´ăŤăŚĺäťć¸ăżă MFD8/12 MFDBB(MPU-001) E_RD-P NC NC E_RD-N NC NC ăăŤăăăĄăłăŻăˇă§ăłăăŁăšăăŹă¤ *3 MULTI-FUNCTION DISPLAY RJ45 E_TD-P 1 MFD8/12 MFDBB(MPU-001) E_TD-N 2 ăŻă BLK RJ45 12-24VDC VVRx2C ăăŻăźăľăăŠă¤ăŚăăă *1 1/Apr/08 DWG.No. SCALE T.TAKENO T.YAMASAKI C3569-C01- C MASS kg 2/Apr/08 R.Esumi 1/Apr/08 APPROVED CHECKED DRAWN Ď7 ăˇă WHT ăŻă BLK NETWORK E_TD-P E_TD-N E_RD-P NC NC E_RD-N NC NC REF.No. Ď7 NAME ĺ 称 TITLE NETWORK E_TD-P E_TD-N E_RD-P NC NC E_RD-N NC NC RW-4747,0.3m TB101 POWER 1 48V-H 2 48V-C B2 RTR-092/093 NMEA2000 TB102 SHIELD 犺ä¸çˇé¨ NET-S ANTENNA UNIT NET-C RSB-118 NET-H NET-L INTERCONNECTION DIAGRAM RADAR SENSOR ç¸äşçľçˇĺł DRS4A/6A ăŹăźăăźăťăłăľăź *3 RJ45 ăˇă WHT ăŻă BLK MOD-ASW0001, 10/15/20/30m,Ď6 *2 M12-05BFFM,1/2/6m CB-05BFFM,1/2/6m ă˘ăŤ RED ăŻă BLK ăˇă WHT ă˘ăŞ BLU 03-174-6003-3 POWER 1 48V-H 2 48V-C RSB-118 OR PSU-012 *3 MJ-A3SPF *3 MOD-ASW0001,Ď6 10/15/20/30m RJ45 *1 IV-2sq. *3 RJ45 čŞćłčŁ 罎ăžăăŻăťăłăľăź NAV.EQUIPMENT OR SENSOR GP-330B SC-30 WS-200 etc. J2 POWER SUPPLY UNIT E_TD-P PSU-012 *2 E_TD-N E_RD-P NC NC E_RD-N NC NC J1 1 (+) J11 48V-H 48V-L 3 (-) SHIELD JUNCTION BOX RJ45 TL-CAT-012 *2 ăžă㯠OR *3 ETHERNET HUB RJ45 HUB-101 *2 PSU-012ă使ăăŞăĺ ´ĺ WHEN PSU-012 IS NOT USED *2 *3 MOD-Z072,2/5/10m,Ď6(CROSS) OR RJ45 MOD-WPAS0001,3m *2 MOD-WPAS0001,3m *3 RJ45 VL3P-VVS2x2C,5m ăˇă WHT (2/10m *2) MOD-Z072,5m,Ď6 12-24VDC J3 1 (+) 2 (-) S-2 C *3 NOTE *1: SHIPYARD SUPPLY. *2: OPTION. *3: CONNECTOR PLUG FITTED AT FACTORY. *4: ATTACH A TERMINATOR. ćł¨č¨ ďźďźďźé čšććé ă ďźďźďźăŞăăˇă§ăłă ďźďźďźăłăăŻăżăŻĺˇĽĺ ´ăŤăŚĺäťć¸ăżă ďźďźďźăżăźăăăźăżăćĽçśăăă E_TD-N E_RD-P NC NC E_RD-N NC NC RJ45 MFDBB(MPU-001) MFD8/12 E_TD-P 1 *3 RJ45 J1 1 (+) 3 (-) E_TD-P E_TD-N E_RD-P NC NC E_RD-N NC NC VVRx2C *1 DWG.No. SCALE T.TAKENO T.YAMASAKI C3571-C01- D MASS kg 12/Jun/08 R.Esumi 28/May/08 APPROVED CHECKED DRAWN Ď7 ăˇă WHT ăŻă BLK *3 RJ45 REF.No. 03-174-6003-3 PSU-012 *3 *2 RJ45 J2 MOD-Z072,2/5/10m,Ď6 1 E_TD-P 2 E_TD-N 3 E_RD-P 4 NC P P 5 NC 6 E_RD-N 7 NC 8 NC 28/May/08 *1 IV-2sq. JUNCTION BOX TL-CAT-012 ăžă㯠OR *2 *3 *3 MOD-Z072,2/5/10m,Ď6(CROSS) OR RJ45 ETHERNET HUB RJ45 MOD-WPAS0001,3m HUB-101 P P 12-24VDC *3 RJ45 MOD-ASW0001,10/15/20/30m,Ď6 čŞćłčŁ 罎ăžăăŻăťăłăľăź NAV. EQUIPMENT OR SENSOR GP-330B SC-30 WS-200 etc. *3 MJ-A3SPF J11 48V-H 1 48V-L 2 SHIELD 3 E_TD-P E_TD-N E_RD-P NC NC E_RD-N NC NC ăăŻăźăľăăŠă¤ăŚăăă POWER SUPPLY UNIT PSU-012 *2 J2 J3 PSU-012ă使ăăŞăĺ ´ĺďźMFDBBăŽăżďź WHEN PSU-012 IS NOT USED (FOR MFDBB ONLY) ăŻă BLK VL3P-VVS2x2C,5m ăˇă WHT 12-24VDC *2 MOD-Z072,2/5/10m,Ď6 MOD-WPAS0001,3m *3 MFDBB(MPU-001) ONLY MJ-A3SPF +48V 1 GND 2 SHIELD 3 E_RD-P NC NC E_RD-N NC NC ăăŤăăăĄăłăŻăˇă§ăłăăŁăšăăŹă¤ *3 MULTI-FUNCTION DISPLAY RJ45 MFDBB(MPU-001) E_TD-P 1 MFD8/12 E_TD-N 2 J3 1 (+) 2 (-) J207 NETWORK E_TD-P E_TD-N E_RD-P NC NC E_RD-N NC NC NAME ĺ 称 TITLE INTERCONNECTION DIAGRAM RADAR SENSOR ç¸äşçľçˇĺł DRS12A ăŹăźăăźăťăłăľăź RW-4747,0.3m TB101 POWER 1 48V-H 2 48V-C B2 RTR-094 NMEA2000 TB102 犺ä¸çˇé¨ SHIELD ANTENNA UNIT NET-S RSB-118 NET-C NET-H *4 NET-L S-3 C 12/24VDC *3 RJ45 NOTE 1. SHIPYARD SUPPLY. 2. OPTION. 3. CONNECTOR PLUG FITTED AT FACTORY. 12-24VDC VVRx2C *2 *3 MOD-Z072,2/5/10m,Ď6(CROSS) OR RJ45 MOD-WPAS0001,3m RJ45 ăŻă BLK VL3P-VVS2x2C,5m ăˇă WHT (2/10m *2) MOD-Z072,5m,Ď6 *2 MOD-WPAS0001,3m ćł¨č¨ ďźďźé čšććé ă ďźďźăŞăăˇă§ăłă ďźďźăłăăŻăżăŻĺˇĽĺ ´ăŤăŚĺäťć¸ăżă E_TD-N E_RD-P SW-P SW-N E_RD-N NC NC RJ45 MFDBB(MPU-001) MFD8/12 E_TD-P 1 *3 E_TD-N E_RD-P SW-P SW-N E_RD-N NC NC ăăŤăăăĄăłăŻăˇă§ăłăăŁăšăăŹă¤ MULTI-FUNCTION DISPLAY *3 MFDBB(MPU-001) RJ45 MFD8/12 E_TD-P 1 *1 *2 M12-05BFFM,1/2/6m CB-05BFFM,1/2/6m ă˘ăŤ RED ăŻă BLK ăˇă WHT ă˘ăŞ BLU DWG.No. SCALE *3 RJ45 C3573-C01- A MASS kg Mar.12'08 R.Esumi REF.No. (-) J1 (+) PSU-013 ăˇă WHT ăŻă BLK ă˘ăŞ BLU J2 E_TD-P E_TD-N E_RD-P SW-P SW-N E_RD-N NC NC T.TAKENO ă˘ăŤ RED T.YAMASAKI ăŻă BLK VL3P-VVS2x2C,5m ăˇă WHT Feb. 22 '08 CHECKED Feb. 22 '08 APPROVED DRAWN 12/24VDC RJ45 MOD-ASW0002,10/15/20/30m,Ď6 (2/10m *2) MOD-Z072,5m,Ď6 *1 IV-2sq. E_TD-P E_TD-N E_RD-P SW-P SW-N E_RD-N NC NC J5 TXHV 1 J4 +48V 1 GND 2 GND 3 JUNCTION BOX RJ45 TL-CAT-012 *2 ăžă㯠OR *3 ETHERNET HUB RJ45 HUB-101 *2 J1 1 (+) 3 (-) E_TD-P E_TD-N E_RD-P SW-P SW-N E_RD-N NC NC ăăŻăźăľăăŠă¤ăŚăăă POWER SUPPLY UNIT PSU-013 J2 J3 čŞćłčŁ 罎ăžăăŻăťăłăľăź NAV.EQUIPMENT OR SENSOR GP-330B SC-30 WS-200 etc. J3 1 (+) 2 (-) POWER TB101 1 48V-H 2 48V-C NAME ĺ 称 TITLE RADAR SENSOR ç¸äşçľçˇĺł DRS25A ăŹăźăăźăťăłăľăź INTERCONNECTION DIAGRAM RW-4747,0.3m J207 NETWORK E_TD-P E_TD-N E_RD-P NC NC E_RD-N NC NC J305 1 TXHV 2 NC 3 GND B2 RTR-095 03-174-6003-3 RJ45 NMEA2000 TB102 SHIELD 犺ä¸çˇé¨ NET-S ANTENNA UNIT NET-C RSB-118 NET-H NET-L S-4 The paper used in this manual is elemental chlorine free. ăťFURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN Telephone : +81-(0)798-65-2111 Fax : +81-(0)798-65-4200 All rights reserved. Printed in Japan A : JAN . 2008 B2 : JAN . 06, 2011 Pub. No. IME-35670-B2 (HIMA ) DRS2D/4D/4A-25A *00016745111* *00016745111* * 0 0 0 1 6 7 4 5 1 1 1 *
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2007:12:25 17:44:34+09:00 Modify Date : 2011:01:06 17:13:22+09:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Producer : Acrobat Distiller 7.0 (Windows) Metadata Date : 2011:01:06 17:13:22+09:00 Document ID : uuid:d883d8f6-fb46-495c-8e04-6662ae4f65da Instance ID : uuid:f0816932-b78a-41c9-8d62-1f3a5872d584 Format : application/pdf Title : untitled Page Mode : UseOutlines Page Count : 40EXIF Metadata provided by EXIF.tools