Furuno Fm 8800D 8800S Users Manual
FM-8800D8800S to the manual 40544afb-e88c-4693-b79f-a70d6789e633
2015-02-02
: Furuno Furuno-Fm-8800D-8800S-Users-Manual-429124 furuno-fm-8800d-8800s-users-manual-429124 furuno pdf
Open the PDF directly: View PDF .
Page Count: 69
Download | |
Open PDF In Browser | View PDF |
VHF RADIOTELEPHONE FM-8800D/8800S PRINTED IN JAPAN The paper used in this manual is elemental chlorine free. FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya 662-8580, JAPAN Telephone : 0798-65-2111 Fax 0798-65-4200 : All rights reserved. Printed in Japan FIRST EDITION : SEP. 2004 E Pub. No. IME-56420-E ( TATA ) FM-8800D/S : JUN. 15, 2006 *00014993204* *00014993204* *00014993204* *IME56420E00* *IME56420E00* *IME56420E00* SAFETY INSTRUCTIONS CAUTION WARNING Attach securely protective earth to the ship's body. Hazardous voltage. Can shock, burn or cause serious injury. The protective earth (grounding) is required to the AC/DC power supply unit to prevent electrical shock. Do not work inside the equipment unless totally familiar with electrical circuits. Do not approach the antenna closer than 0.9 m (MPE by FCC) when it is transmitting. Confirm that the power supply voltage is compatible with the voltage rating of the equipment. The antenna emits radio waves which can be harmful to the human body. Connection to the wrong power supply can cause fire or equipment damage. The voltage rating appears on the label at the rear of the display unit. RF power density Description Distance on antenna aperture required by 100 W/m FM-8800S FM-8800D 2 10 W/m 2 W/m 2 100 W/m 2 0.11 m IEC 60945 0.33 m IEC 60945 0.9 m MPE by FCC 0.11 m IEC 60945 10 W/m 2 2 W/m 2 0.33 m IEC 60945 0.9 m MPE by FCC 2 (MPE: Minimum Permissible Exposure) Turn off the power at the mains switchboard before beginning the installation. Post a warning sign near the switchboard to indicate that power should not be applied while the equipment is being installed. Electrical shock, serious injury or fire can result if the power is not turned off or is applied while the equipment is being installed. Observe the compass safe distance to prevent deviation of a magnetic compass. Standard compass Steering compass FM-8800S 1.45 m 0.90 m FM-8800D 1.45 m 0.95 m IF-8810 0.85 m 0.55 m IF-8820 0.75 m 0.50 m HS-2003 1.50 m 0.95 m HS-8800 0.40 m 0.30 m RB-8800 (W/HS-8800) 1.20 m 0.80 m 1.50 m 1.00 m 0.90 m 0.60 m RB-8810 (W/HS-8800) PR-240-CE i TABLE OF CONTENTS SYSTEM CONFIGURATION................................................................................ iii EQUIPMENT LISTS ........................................................................................... iv 1. MOUNTING ................................................................................................... 1-1 2. CONNECTIONS ............................................................................................ 2-1 3. ASSEMBLING CONSOLE KIT ..................................................................... 3-1 PACKING LISTS ............................................................................................... A-1 OUTLINE DRAWINGS ...................................................................................... D-1 INTERCONNECTION DIAGRAMS ....................................................................S-1 ii SYSTEM CONFIGURATION VHF Antenna CH 70 RX Antenna VHF console RC-8800 Wing handset MAX 2 sets T/R AF output for VDR Handset HS-2003 Transceiver Unit Junction Box* IF-8810 IEC61162-1 input DSC information output External alarm Remote station RB-8800/8810 FM-8800D FM-8800S DMC I/F IF-8820 MAX 4 sets RB-8800/8810 Printer IF+UTP-80FK Distress Message Controller DMC-5 Printer PP-510 PP-8800 100-115/200-230 VAC 50/60 Hz, 1φ Radio Battery 24 VDC AC/DC Power Supply Unit PR-240-CE Omit for Russian Version External Speaker SEM-21Q 24 VDC : Standard : Optional Category of units Unit Category Antenna Exposed to weather All other units Protected from weather *: Option for FM-8800S/D-N iii EQUIPMENT LISTS Standard Supply Name 1 Transceiver Unit Type FM-8800D-E-A FM-8800D-E-N FM-8800D-F-A FM-8800D-F-N FM-8800S-E-A FM-8800S-E-N FM-8800S-F-A FM-8800S-F-N FM-8800S-R-A FM-8800S-R-N Qty 1 FP05-05700 2 Accessories* 4 5 Junction Box Installation Materials* Spare Parts* Remarks D: Duplex S: Simplex E: With handset HS-2003 F: With microphone DM-2003-F A: With IF-8810 N: No IF-8810 R: Russian version — 000-054-228 1 FP05-05710 3 Code No. 000-054-156 IF-8810 1 — CP05-09900 1 000-054-227 SP05-05501 1 005-377-820 For E-type Handset HS-2003, Hanger FP05-05510, Others FP05-05511 For F-type Microphone DM-2003-F For A-type Power cable 05S9371, CP05-09901 Standard Supply for VHF Console 1 Name VHF Console Type RC-8800-SN RC-8800-DN RC-8800-SA RC-8800-DA Qty 1 Code No. — 2 Installation Masteries* CP05-10201 1 005-371-850 3 Accessories* FP05-05800 1 000-054-372 5 Spare Parts* SP05-05501 1 005-377-820 Remarks D: Duplex FM-8800D S: Simplex DM-8800S N: No printer A: With printer & I/F board Handset HS-2003 & Handset hanger FP05-05510 *: See lists at the end of this manual. iv EQUIPMENT LISTS Optional Equipment Name Type Code No. Remarks Flush Mount Kit OP05-102 Junction Box IF-8810 — W/ Screw 5x20 4 pcs. DMC Interface IF-8820 RB-8800-15 (W/ 1.5 m Cable) RB-8800-20 (W/ 2 m Cable) RB-8810-15 (W/ 1.5 m Cable) RB-8810-20 (W/ 2 m Cable) HS-8800-15 — No use for Russian version — ·FP05-05701*, ·Handset HS-8800, ·Hanger W/DIST. button HG-8800 — ·FP05-05511*, ·Handset HS-8800, ·Hanger HG-8810 000-054-230 W/ 1.5 m Cable HS-8800-20 000-054-171 W/ 2 m Cable HS-8800-W-35 000-054-287 Waterproof HS-2003-15 000-054-223 W/ Cable 1.5 m HS-2003-20 000-XXX-XXX W/ Cable 2.0 m HS-2003-50S 000-XXX-XXX W/ Straight cable 5.0 m HS-6000FZ11 000-135-072 HG-8800 000-054-229 For HS-8800 HG-8810 000-054-231 For HS-8800 FP05-05510 005-951-790 For HS-2003 AP-102 000-580-019 For HS-6000FZ11 Loudspeaker SEM-21Q 000-144-917 Dynamic Mic. Set OP05-57 000-045-775 Carbon Mic. Set OP05-58 000-045-776 Handset set OP05-42 000-045-778 Mic. Receptacle Box Microphone RBD-VHF (B) 000-056-094 DM-2003-F 005-377-760 Printer PP-510 — Printer Interface IF-8500 — AC-DC Power Supply PR-240-CE — Remote Station Handset Handset Hanger Antenna Material 000-054-120 AP05-00800 000-057-721 AP05-00810 000-057-722 AP05-00900 000-057-739 AP05-01000 000-054-123 Handset HS-6000FZ5, Receptacle RDB-VHF(B), Hanger AP-102 Handset HS-6000FZ6, Receptacle RDB-VHF, Hanger AP-102 Handset HS-6000FZ11, Receptacle RDB-VHF(B), Hanger AP-102 Whip antenna FAB-151D, Mounting plate 4-310071, Coax. Cable 5D-2V 10m, Connector M-P-5 2 PCS Whip antenna RA106, Mounting plate RA115, Coax. Cable 05S9104 5m Whip antenna 396-1, Mounting plate 4187 Whip antenna FAB-151D, Mounting plate 4-310071, Connector M-P-7 2 PCS *: See lists at the end of this manual v EQUIPMENT LISTS Name Antenna Material Signal Cable Twisted Cable VHF Console Kit Type AP05-01100 000-054-224 AP05-01200 000-054-232 AP05-01210 000-054-233 05S0309 *10M* 000-106-043 Whip antenna 150M-W2VN, Coax. Cable 5D-2V 10m, Connector M-P-5 2 PCS Whip antenna FAB-151D, Mounting plate 4-310071, Coax. Cable 5D-2V 10m, Connector M-P-5 & M-P-7 Whip antenna FAB-151D, Mounting plate 4-310071, Coax. Cable 5D-2V 20m, Connector M-P-5 & M-P-7 10m 05S0309 *20M* 000-106-044 20m 05S0309 *30M* 000-106-046 30m 05S0309 *40M* 000-106-047 40m 05S0309 *50M* 000-106-048 50m 000-111-680 5m 000-120-792 10m 000-120-793 15m 000-120-794 20m CO-SPEVV-SB-C 0.2x2P 000-120-214 30m RC-8800-N-75BG 000-054-125 Without Printer RC-8800-A-75BG 000-054-126 With Printer Printer PP-8800 - Emergency lamp EMG-1T 000-138-378 vi Remarks Code No. W/ power cable For rack console, cable attached 1. MOUNTING Transceiver Unit General mounting considerations Determine the mounting location for the transceiver unit considering operator convenience, proximity to the power source and the ground location. Keep these and the following points in mind when selecting a mounting location. • Locate the unit in a place free of water spray and water splash. • Keep the unit out of direct sunlight because of heat that can build up inside the unit. • Leave a little slack in cables to allow a service technician to move the radio from its usual location with the cables connected. This lets him make tuning and other adjustments on a “live” set. • Do not install the unit where flammable gases are stored. • Select a well-ventilated area. • Ensure the mounting location is strong enough to support the weight of the unit (approx. 6 kg) under the condition of continued vibration normally encountered aboard the vessel. If necessary, reinforce the mounting area with a doubling plate or lining block. • Leave sufficient space at the sides and rear of the unit for maintenance and service purposes and to provide for circulation of cooling air. See outlines drawings at the back of this manual. • For flush mounting, select a location where the LCD can be easily viewed. • The transceiver unit will affect a magnetic compass if placed too near the compass. Observe the compass safe distance to prevent deviation of a magnetic compass, referring to page “ i ”. Note: Take great care not to press the DISTRESS switch during the installation. If you accidentally press the switch, immediately turn off the equipment and contact appropriate authority by telephone. 1-1 1. MOUNTING Overview of mounting methods Keep pressed for 4 s in case of DISTRESS. The alert is transmitted with steady lighting. DISTRESS 1 2 4 IntCom GHI ALM STOP CALL Keep pressed for 4 s in case of DISTRESS. The alert is transmitted with steady lighting. DISTRESS 1 2 4 IntCom GHI ALM STOP MSG 7 INTL USA PQRS SHIFT * CANCEL CALL ABC 5 ACK 8 SCAN 0 HI/L0 JKL TUV 3 6 9 # TEST DEF USA SHIFT ABC 5 ACK 8 SCAN 0 HI/L0 JKL TUV 3 6 9 # TEST DEF PRINT MNO DW WXYZ LOG CH16 FILE MENU ENT FILE MNO DW INTL PQRS CH16 PRINT WXYZ MSG 7 * CANCEL MENU LOG ENT Overhead Tabletop Keep pressed for 4 s in case of DISTRESS. The alert is transmitted with steady lighting. DISTRESS 1 2 4 IntCom GHI 7 ALM STOP CALL MSG Flush Mount INTL USA PQRS SHIFT * CANCEL ABC 5 ACK 8 SCAN 0 HI/L0 JKL TUV 3 6 9 # TEST DEF PRINT MNO DW WXYZ LOG CH16 FILE MENU ENT Bulkhead Overview of mounting methods 1-2 1. MOUNTING Mounting procedure for tabletop, overhead and bulkhead mounting 1. Using the hanger as a template, mark fixing holes in the mounting location. 2. Fix the hanger to the mounting location with self-tapping screws and washers (supplied). (For added support, use nuts, bolts and washers instead of self-tapping screws.) 3. Screw the knob bolts with washers into the transceiver unit. 4. Set the transceiver unit to the hanger and tighten knob bolts. 265 251 Keep pressed for 4 s in case of DISTRESS. The alert is transmitted with steady lighting. 1 DISTRESS 110 2 ABC 3 TEST DEF 4 IntCom 5 ACK 6 PRINT INTL 8 SCAN 9 DW 0 HI/L0 # GHI JKL MNO CH16 FILE ALARM CANCEL 7 ALM STOP SQL VOL/PWR CH CALL SHIFT MSG OFF TUV * HANDSET USA PQRS WXYZ LOG MENU ENT PUSH TO ENTER AUTO Keep pressed for 4 s in case of DISTRESS. The alert is transmitted with steady lighting. DISTRESS 1 2 4 IntCom GHI ABC 5 ACK 8 SCAN 0 HI/L0 JKL 3 6 TEST DEF PRINT MNO CH16 FILE ALARM 7 ALM STOP HANDSET SQL VOL/PWR CH CALL MSG OFF AUTO INTL USA PQRS SHIFT * 100 CANCEL TUV 9 # DW WXYZ LOG MENU 100 ENT PUSH TO ENTER • All dimensions in millimeters. • Leave sufficient space at the sides and rear of the unit to provide easy access for maintenance and service. Mounting dimensions for tabletop, overhead and bulkhead mounting 1-3 1. MOUNTING Mounting procedure for flush mount (option) Requires optional flush mount kit OP05-102 (Code No. 000-054-120). Prepare a cutout in the mounting location whose dimensions are as shown in the figure below. Flush mount kit OP05-102 Name 1 Mounting plate 2 Self-tapping screw 3 Hex screw Code No. 100-323-160 000-802-081 000-882-075 Qty 1 4 2 #150 251 260 ± 1 280 ± 1 277 ± 0.5 122 ± 0.5 244 105 ± 1 30 ± 1 20 14 27 Type 05-093-1211 5x20 M8x16 Pilot holes (4 pcs.) Mounting dimensions for flush mount VHF Antenna The antenna requirements Any good quality antenna meeting the requirements shown below may be used. A high-gain antenna is preferable. • Frequency range: 155 to 164 MHz • Impedance: 50 ohms • Polarization: Vertical • Handling power: 30 W/ min • Quality: Able to withstand marine environment Mounting considerations • The antenna should be well separated from nearby antennas, masts, and other interfering objects. • The higher the antenna is mounted above the horizon, the further the communications range. Mounting procedure The basic mounting procedure for antennas supplied by FURUNO is as follows, however consult appropriate outline drawing for details. 1. Fasten the antenna bracket to the stanchion. 2. Set the antenna to the antenna bracket and tighten bolts. 3. Screw the coaxial cable plug into the antenna. 1-4 1. MOUNTING CH70 RX Antenna The antenna should be well separated from nearby antennas, masts, and other interfering objects. The mounting procedure is the same as that for the VHF antenna, however consult appropriate outline drawing for details. Handset Hanger The handset hanger can be mounted at the left side of the transceiver unit. The mounting location should provide easy access to front panel controls while operating the handset. Also, the length of the standard handset cable is 50 cm, so locate the handset hanger within 50 cm of the unit. (Longer cables are available optionally.) Power Supply (option) For Convention vessels, both AC and DC power must be fed to the FM-8800D/8800S, via an AC/DC power supply. When AC input fails, DC power is supplied. FURUNO can supply an AC/DC power supply unit, the PR-240-CE. Mounting considerations When selecting a mounting location, keep in mind the following points. • Select a location which provides adequate ventilation. • The location must be clean and dry. • The mounting location must be able to support the weight of the unit (14.5 kg) under the continued conditions of vibration normally encountered aboard the vessel. If necessary, reinforce the mounting location. • The PR-240-CE will affect a magnetic compass if it is placed to near the compass. Observe the compass safe distance to prevent deviation of a magnetic compass, referring to page “ i ”. Mounting Refer to outline drawing. 1-5 1. MOUNTING Printer (option) Printer PP-510 To mount the printer, refer to the printer outline drawing at the back of this manual. 1. Select a flat surface. 2. Fix the mounting base to the mounting location with four screws (supplied). 3. Lay the printer on the top of the mounting base and fasten it with the mounting fixtures (two at each side and one at rear). Mounting Fixture Mounting Fixture Mounting Dimensions 300 (H) x 396 (W) mm Mounting of Printer PP-510 Printer PP-8800 The printer PP-8800 is flush-mounted in a panel. Refer to the outline drawing at the back of this manual. 1. Make a cutout of 208(w) x 118(h) mm. 2. Set the printer and fix it with four self-tapping screws (4x16). Printer Interface (option) The printer interface IF-8500 is required for the printer PP-510 which is commonly used with the FM-8800D/S and other MF/HF radio communication equipment. To mount the unit, see the outline drawing at the back of this manual. External Loudspeaker (option) The external loudspeaker can be installed on a tabletop, the overhead or a bulkhead. Fasten the loudspeaker to the mounting location with self-tapping screws, or nuts, bolts and washers. For mounting dimensions, see the outline drawing at the back of this manual. 1-6 1. MOUNTING Junction box IF-8810/ DMC interface IF-8820 Note: DMC interface IF-8820 is not used for Russian version. To install the remote box RB-8800/RB-8810, wing handset, etc., the junction box IF-8810 is required. Install the junction box near the transceiver unit. Approx. 3 m cable is preattached to the junction box to connect to the transceiver unit. To connect Furuno’s distress message controller DMC-5, the DMC interface IF-8820 (option) is required. 1. Open the cover. 2. Mount the unit with four self-tapping screws (5x20). 240 100 Note: This plug is not fitted in IF-8820. Fixing holes 5mm dia. Mounting the junction box/DMC interface 1-7 1. MOUNTING Remote station RB-8800/RB-8810 (option) Up to four remote stations can be connected in a daisy chain. Note: For the remote station RB-8800, there are two method of cable entry: bottom-side entry and rear-side entry. For rear-side entry, make one or two holes of more than 12 mm diameter. For last station in the daisy chain, just one cable entry hole is needed. 1. Remove screws on the handset hanger (four for RB-8800, six for RB-8810). 2. Remove upper chassis of the hanger. 3. Mount the base of the hanger to a bulkhead with self-tapping screws 4x20 (four for RB-8800), or 4x16 (two for RB-8810). 4. After connecting cables, assemble the remote station. 5. For RB-8800, attach blind seals on the screws. Cover of handset hanger 63 Handset hanger HG-8800 20 30 33 Screws 4 pcs. Attach blind seal on the screws. 40 Nameplate DISTRESS Cable entry (Rear) 140± 0.5 φ 12 Handset HS-8800 φ 12 Cable entry 77 VOLUME #150 4- φ4.5 Fixing holes 40 ± 0.5 40 ± 0.5 Cable entry (Bottom) Remote station RB-8800 Hanger HG-8810 (77) Handset HS-8800 57 22 145 ± 0.5 208 (208) #150 φ12, Cable entry Nameplate 2- φ4.5 Fixing hole Hanger Hanger mounting base Remote station RB-8810 1-8 42 Cable entry 65 1. MOUNTING Outdoor mounting of RB-8810 Remote station RB-8810 with waterproof-type handset HS-8800-W-35 can be mounted outdoors. The hanger should be coated as directed below with silicone sealant for waterproofness. 1. Fix the mounting base with self-tapping screws. Coat exposed part of these screws with silicone sealant. 2. Attach the cable from the transceiver unit or junction box. Coat cable around cable entrance with silicone sealant 3. Fix the cover of the handset hanger. Coat junction between mounting base and cover with silicone sealant. 2. All around the cable at cable entry Self-tapping screws 3. All around the junction coating parts Note: Confirm that plastic washers are in screw holes before fixing cover. 1-9 1. MOUNTING VHF console Install the rack console where the equipment can be easily operated, checked and serviced. Consult with shipyard personnel and ship's officer-in-charge to determine best location. The location must satisfy the following points: • Select a location where controls can be easily operated. • Select a location where shock and vibration are minimal. • Locate the console away from water splash and rain. • The temperature and humidity of the location should be both stable and moderate. Fixing 1. Ask shipyard personnel to tighten six M5 nuts or six M5 bolts to the fixing holes (on the wall), referring to the outline drawing at the back of this manual. 2. Detach the cover assembly from the console. 3. Hang VHF console on bolts. 4. Screw the console with the bolts or nuts tightly. 5. Attach the cover assembly to the console. Note: When you connect wires as soon as attaching console, refer to paragragh 2-10. 6. Attach the handset hanger with two screws. 7. To attach the optional emergency lamp, connect the cable to the terminal board, and then attach the lamp to the console. Refer to the interconnection diagram and out line drawing. (371) EMG-1T EMERGENCY LAMP 190 ° 75 (371) 330 145 480 (500) 30 298 ± 0.5 1-10 FIXING HOLES TERMINAL BOARD (266) #50 CABLE ENTRY (REAR) 250 30 40 170 ± 0.5 170 ± 0.5 40 HANDSET HANGER 2. CONNECTIONS Overview The figure below shows where to connect various equipment at the rear of the transceiver unit. ANT Connects antenna. Ground terminal. 24VDC Connects power cable. PRINTER Connects printer PP-510. IEC61162-1 (NMEA)/REMOTE Connects junction box IF-8810. EXT SP Connects external loudspeaker. CH70 RX ANT Connects DSC antenna here. FM-8800D/8800S, rear view Connection of Power Supply Convention vessels, 100/220 VAC ship’s mains Convention vessels must supply both AC and DC power to the FM-8800D/8800S, via an AC/DC power supply unit. Both AC and DC are supplied by the AC/DC power supply unit, and when AC input fails DC power is activated. Connect the radio battery to the DC IN terminal on the PR-240-CE. Connect the AC ship’s mains to the AC IN terminal on the PR-240-CE. Radio battery (24 VDC) Attach the connector supplied to the power cable and plug it into the 24VDC connector at the rear of the transceiver unit. Connect the wire ends to the radio battery line. 2-1 2. CONNECTIONS Connection of VHF Antenna The VHF antenna is connected to the transceiver unit with a 50 ohm coaxial cable, type 5D-2V. Be sure to leave some slack in the cable for future service and maintenance. Lay the coaxial cable and attach an M-type plug to the cable (if necessary) as follows. 1. 2. 3. 4. 5. Remove the sheath by 20 mm. Bare 13 mm of the center conductor. Trim braided shield by 5 mm and tin. Slide coupling ring onto cable. Screw the plug assembly on the cable. Solder plug assembly to braided shield through solder holes. Solder contact sleeve to conductor. 6. Screw coupling ring into plug assembly. 7. Screw the plug into the ANT connector at the rear of the transceiver unit. How to attach the M-type plug to the coaxial cable 2-2 2. CONNECTIONS Connection of DSC Antenna The DSC antenna is connected to the transceiver unit with a 50 ohm coaxial cable, type 5D-2V. Attach an M-type plug to the cable (if necessary) as shown an page 2-2. Screw the plug into the CH70 RX ANT connector at the rear of the transceiver unit. Connection of Handset Connect the handset cable to the HANDSET connector on the front panel. Grounding the Transceiver Unit Fasten a ground wire (local supply) between the GND terminal at the rear of the transceiver unit and ship’s hull (or ground bus). Connecting the Junction Box The junction box is required to connect a remote station, wing handset, etc. The cable to be connected with the transceiver unit is prefitted on the junction box at the factory. For connection of other cables, see the interconnection diagram. Cable entry Clamp the cable with U-type cable clamps. Use one of these nuts for ground terminal between JB and ship's body. Cable clamp: Clamp shield part of the cables to ground cables. 2-3 2. CONNECTIONS Connecting the Remote Station without the Junction Box The remote station (or DMC Interface, Mic. Receptacle box, etc) can be connected directly to the transceiver unit, using the D-sub connector supplied as installation materials. Attach the connector to the cable as follows. Shield tape (metal) Fold back the armor, and then wind the shield tape along the edge of cable. Cable clamp Cable Connector XM2A-3701 & Housing case XM2S-3712 Attachment of connector When the handset HS-2003 is not connected to the Transceiver unit When the handset HS-2003 is not connected to the transceiver unit, i.e.,always the remoted handset is used, the following modification is necessary. 1. Dismount the cover of the transceiver unit by removing four screws at the rear panel and two screws at the side. 2. Dismount the bottom cover by removing seven screws. J15 CPU board 05P0773 3. Shorten between #1 and #2 of J15. The handset line of the HANDSET port becomes always “ON HOOK”. 4. Assemble the unit. 2-4 2. CONNECTIONS Connection of AC/DC Power Supply Unit PR-240-CE The power supply PR-240-CE is shipped ready for connection to a 200-230 VAC ship’s mains. If the ship’s mains is 100 VAC – 115 VAC, change the tap connection and terminal board connection as below. Attach label supplied as accessories to the punch mark in the front panel according to the ship’s mains. Ship’s mains Tap connection Terminal board connection #1 & #2 100-115 VAC SEL 115 V b 200-230 VAC SEL 230 V a 100-115 VAC 200-230 VAC 1 White 1 White 2 Black 2 Black 3 3 Punch mark (a) (b) Front SEL 115 V 1 2 3 4 5 6 7 8 SEL 230 V Terminal board connection Heat sink Tap connection (Pull out to disconnect) Top view of AC/DC power supply unit (cover removed) 2-5 2. CONNECTIONS Protective earth Connect IV-2.0sq wire between ship’s superstructure and the ground terminal on the PR-240-CE. CAUTION Attach protective earth securely to the ship's body. The protective earth (grounding) is required for the AC/DC power supply unit to prevent electrical shock. Attach a label here. GND terminal PR-240-CE Front panel 2-6 2. CONNECTIONS Jumper Setting for Termination Note: DMC interface is not used for Russian version. It is necessary, for termination, to change the jumper setting for remote station or DMC interface. Open the unit(s) terminated and change the jumper plugs J2 and J3 to ON position (#2-#3). (Default setting is OFF position.) Transceiver Unit Junction Box Remote Station Remote Station DMC I/F Remote Station Remote Station Remote Station Terminated Unit Note that up to four remote stations can be connected. LINE TERMINATION J3 DISTRESS 1 ON RS-485 TERMINATION J2 3 1 ON 3 J1 Set to ON (#2-3) for termination. 05P0782 TB1 VOLUME TB2 Remote station RB-8800 Cable entry TB1 TB2 J3 3 3 ON OFF 1 J2 RS-485 TERMINATION LINE TERMINATION ON OFF 1 05P0798 2- φ 4.5 Set to ON (#2-3) for termination. J1 Fixing hole Remote station RB-8810 2-7 2. CONNECTIONS Remove four screws to open the unit. Set jumper plug to ON (#1-2). 05P0778 J4 ON RS-485 TERMINATION TB1 DMC Interface IF-8820 2-8 2. CONNECTIONS 2.10 Wire connection of VHF console 1. Remove the cover assembly and printer assembly (or concealing lid) form the console. For the printer assembly, remove the cables connected at the Transceiver Unit and the terminal board. Cover assembly Binding screw F M4X10 8 places Binding screw F M4X10 4 places Printer assembly or Concealing lid Console Terminal board 2. Connect the power cable from the ship to the terminal block 1 (+) and 2 (-). Terminal Board Wiring 1. Wiring conductor 9∼10mm 2. Wiring 1)Insert a screwdriver which blade edge is 3.5 X 0.5mm to the square hole. 2)Press the screwdriver to arrow direction to open the spring in the round hole. 3)Insert the wire to the round hole. 4)Remove the screwdriver. Power cable from the ship 1 2 1 2 3 4 5 6 7 8 - Square hole Round hole Terminal board 3. Connect the ground wire from ship to each ground terminal for the transceiver unit and the junction box. 4. Connect cables from external equipments to the junction box. 5. Fix the printer assembly (or concealing lid) and the cover assembly. 2-9 2. CONNECTIONS This page is intentionally left blank. 2-10 3. ASSEMBLING CONSOLE KIT A VHF console kit is required to mount the Transceiver Unit in the field. There are two types as shown below. VHF console kit Type RC-8800-N-75BG RC-8800-A-75BG Code No. 000-054-125 000-054-126 Remarks Without printer With printer Assembling the Console Kit 1. Remove the cover assembly, the panel assembly and the printer assembly (or concealing lid) from the console. For the printer assembly, remove the cable connected to the terminal board. Cover assembly Binding screw F M4X10 8 places Binding screw F M4X10 4 places Printer assembly (or Concealing lid # # Remove screws( )and detach the panel assembly. Console Panel assembly 3-1 2. Fix the panel assembly to the Transceiver Unit with binding screws (use original binding screws of the Transceiver Unit). Refer to the figure below. 3. Screw in hex bolts M8x16 and flat washers loosely at both sides of the Transceiver Unit. Panel assembly Binding screw M4 2 places (Use the original screws of the Transceiver Unit.) Washer M8 2 places Hex bolt M8X16 2 places (faster loosely) 4. Set the Transceiver Unit to the console, remove the grommets from the console and fix the Transceiver Unit with hex bolts using the holes formerly occupied by the grommets. Hex head screws Mounting of the Transceiver Unit Insert console upside down. Close the hole with grommets lastly. Connecter Connecter Mounting plate Transceiver Unit Flat washer Fix Mounting Plate between washers. 5. Connect connector from the fuse to the power connector derived from the Transceiver Unit. 3-2 6. Replace the cable attached to junction box with the cable (55 cm, 37-pin D sub) supplied with the console kit. Replace the original cable with the cable assembly DSUB37M-PHX3-L550. A Junction box (without cover) PH Connector 10P PH Connector 12P J3 J2 J1 PH Connector 14P 2 3 Crimp-on lug A View 7. Connect the cable (37-pin D sub) attached to the junction box to the Transceiver Unit and then mount the junction box on the console. ±Binding screw F M4X8 4 places Cover ±Screw B M4X10 4 places Mounting plate 3-3 Junction box Grommets 2 places 8. For the console w/printer, connect the printer cable for data transmission to the PRINTER port of the Transceiver Unit and fix the power cable to the terminal board as before. Then, fix the printer assembly to the console. For no printer, fasten the concealing lid to the console. Printer Printer cable W/ Printer J2 Insert the mounting plate for printer to the catch of the console View 9. Fasten the cover assembly. NOTE: If the console assembly is to be mounted on the hull, refer to paragraghs 1-9 and 2-10. 3-4 OUTLINE INSTALLATION MATERIALS ACCESSORIES SPARE PARTS UNIT 005-377-800 000-151-711 CP05-09901 05S9371-0 005-951-920 005-951-790 FP05-05511 000-054-223 FP05-05510 HS-2003 005-377-820 SP05-05501 1 Q'TY 1 1 CP05-09900 1 1 1 FP05-05700 1 SP05-05501 000-054-225 ** FM-8800S/D DESCRIPTION/CODE № (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) DOCUMENT DISTRESS PROCEDURE 遭難通信要領書 OPERATOR'S MANUAL 取扱説明書 INSTALLATION MANUAL 装備要領書 OPERATOR'S GUIDE VHF/MF DISTRESS ALERT FLOW 操作要領書 遭難警報フロVHFMF* 図書 NAME FM-8800S-J/E-N/FM-8800D-J/E-N コ-ド番号末尾の[**]は、選択品の代表型式/コードを表します。 CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL. INSTALLATION MATERIALS 工事材料 CABLE ASSY. ケーブル組品 工事材料 ACCESSORIES 付属品 BRACKET FOR HANDSET ハンドセットハンガー組品 HANDSET ハンドセット 付属品 SPARE PARTS 予備品 予備品 TRANSCEIVER UNIT 送受信機 ユニット NAME PACKING LIST OUTLINE 000-149-935 000-149-930 ** TIC-56420-* 000-149-932 ** OM*-56420-* 000-149-934 ** IM*-56420-* 000-809-270 OS*-56420-* *52-00101-* 1 1 1 1 1 Q'TY 1/1 05EC-X-9851 DESCRIPTION/CODE № 05EC-X-9851 -4 A-1 NAME OUTLINE INSTALLATION MATERIALS ACCESSORIES SPARE PARTS UNIT 005-377-800 CP05-09901 000-054-223 005-951-790 HS-2003 005-951-920 FP05-05510 FP05-05511 005-377-820 SP05-05501 000-054-219 1 1 1 Q'TY 1 CP05-09900 1 1 1 FP05-05700 000-054-166 ** IF-8810 FM-8800S*/D* DESCRIPTION/CODE № (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) DOCUMENT INSTALLATION MANUAL 装備要領書 OPERATOR'S MANUAL 取扱説明書 OPERATOR'S GUIDE 操作要領書 DISTRESS PROCEDURE VHF/MF DISTRESS ALERT FLOW 遭難通信要領書 遭難警報フロVHFMF* 図書 OUTLINE INSTALLATION MATERIALS INSTALLATION MATERIALS 工事材料 工事材料 CABLE ASSY. ケーブル組品 NAME FM-8800S-J/E-A/FM-8800D-J/E-A、FM-8800S-J/E-AHK/FM-8800D-J/E-A-HK コ-ド番号末尾の[**]は、選択品の代表コードを表します。 CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL. INSTALLATION MATERIALS 工事材料 工事材料 HANDSET ハンドセット BRACKET FOR HANDSET ハンドセットハンガー組品 ACCESSORIES 付属品 付属品 SPARE PARTS 予備品 予備品 JUNCTION BOX セツゾクバコ TRANSCEIVER UNIT 送受信機 ユニット PACKING LIST 1/1 1 Q'TY 000-149-932 ** 000-149-930 ** IM*-56420-* 000-149-934 ** OM*-56420-* 1 1 1 1 1 1 CP05-08701 000-149-935 ** OS*-56420-* 000-809-270 TIC-56420-* *52-00101-* 005-949-280 CP05-08701 000-151-711 05S9371-0 DESCRIPTION/CODE № 05EC-X-9856 -3 05EC-X-9856 A-2 DOCUMENT 000-149-932 000-809-270 IM*-56420-* *52-00101-* 005-377-800 000-151-711 CP05-09901 05S9371-0 005-377-760 DM-2003-F 005-377-820 SP05-05501 000-054-225 ** FM-8800S/D 1 1 Q'TY 1 1 1 1 CP05-09900 1 FP05-05710 DESCRIPTION/CODE № (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) DISTRESS PROCEDURE 遭難通信要領書 OPERATOR'S GUIDE 操作要領書 OPERATOR'S MANUAL 取扱説明書 NAME FM-8800S-F-N/FM-8800D-F-N CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL. INSTALLATION MANUAL 装備要領書 VHF/MF DISTRESS ALERT FLOW 遭難警報フロVHFMF* 図書 OUTLINE INSTALLATION MATERIALS ACCESSORIES SPARE PARTS UNIT INSTALLATION MATERIALS 工事材料 CABLE ASSY. ケーブル組品 工事材料 MICROPHONE マイクロフォン箱詰品 付属品 SPARE PARTS 予備品 予備品 TRANSCEIVER UNIT 送受信機 ユニット NAME PACKING LIST OUTLINE 05EC-X-9858 000-149-935 000-149-934 TIC-56420-* 000-149-930 OS*-56420-* OM*-56420-* DESCRIPTION/CODE № 05EC-X-9858 -2 1/1 1 1 1 Q'TY A-3 NAME INSTALLATION MATERIALS 005-949-280 CP05-08701 005-377-800 000-151-711 CP05-09901 05S9371-0 005-377-760 DM-2003-F 005-377-820 SP05-05501 1 1 1 Q'TY 1 1 1 CP05-09900 1 FP05-05710 000-054-225 ** 000-054-219 FM-8800S/D IF-8810 DESCRIPTION/CODE № (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) NAME DOCUMENT DISTRESS PROCEDURE 遭難通信要領書 OPERATOR'S GUIDE 操作要領書 OPERATOR'S MANUAL 取扱説明書 INSTALLATION MANUAL VHF/MF DISTRESS ALERT FLOW 装備要領書 遭難警報フロVHFMF* 図書 FM-8800S-F-A/FM-8800D-F-A CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL. INSTALLATION MATERIALS 工事材料 工事材料 OUTLINE INSTALLATION MATERIALS ACCESSORIES SPARE PARTS UNIT INSTALLATION MATERIALS 工事材料 CABLE ASSY. ケーブル組品 工事材料 MICROPHONE マイクロフォン箱詰品 付属品 SPARE PARTS 予備品 予備品 TRANSCEIVER UNIT 送受信機 JUNCTION BOX セツゾクバコ ユニット PACKING LIST OUTLINE 1/1 000-149-935 000-149-934 TIC-56420-* 000-149-930 OS*-56420-* 000-149-932 OM*-56420-* 000-809-270 IM*-56420-* *52-00101-* 1 1 1 1 1 Q'TY 05EC-X-9859 DESCRIPTION/CODE № 05EC-X-9859 -2 A-4 A-5 PACKING LIST 05EC-X-9857 -1 1/1 DM-2003-F N A M E マイクセット O U T L I N E DESCRIPTION/CODE № Q'TY MICROPHONE SET ZIRXXCDM002 フック 1 HOOK 000-150-017 KON-003 マイクロフォン 1 MICROPHONE 000-150-016 (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 05EC-X-9857 A-6 CODE NO. 005-377-800 TYPE CP05-09901 05EC-X-9401 -2 1/1 工事材料表 INSTALLATION MATERIALS 番 号 NO. 名 称 NAME 型名/規格 DESCRIPTIONS 1 CABLE ASSY. CODE NO. 1 000-145-423 XM2A-3701 コネクタ(XM2) 1 CONNECTOR CODE NO. +トラスタッピンネジ 1種 4 Used only Japan 000-151-748 HOUSING CASE CODE NO. 3 用途/備考 REMARKS XM2S-3712 コネクタフード(XM2) 2 数量 Q'TY L-420 ミニピン組品(1) 1 略 図 OUTLINE 000-145-424 6X20 SUS304 5 SELF-TAPPING SCREW CODE NO. 000-802-084 05EC-X-9401 FURUNO ELECTRIC CO .,LTD. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) A-7 CODE NO. 005-949-280 TYPE CP05-08701 05DY-X-9417 -0 1/1 工事材料表 INSTALLATION MATERIALS 番 号 NO. 名 称 NAME +トラスタッピンネジ 1種 1 略 図 OUTLINE 型名/規格 DESCRIPTIONS 数量 Q'TY 用途/備考 REMARKS 5X20 SUS304 4 SELF-TAPPING SCREW CODE NO. 000-802-081 05DY-X-9417 FURUNO ELECTRIC CO .,LTD. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) A-8 CODE NO. 005-951-920 TYPE FP05-05511 05DZ-X-9502 -0 1/1 付属品表 ACCESSORIES 名 称 NAME 番 号 NO. CODE NO. 2 用途/備考 REMARKS 2 SELF-TAPPING SCREW ポリカワッシャー 数量 Q'TY 4X16 SUS304 1シュ +トラスタッピンネジ 1 型名/規格 DESCRIPTIONS 略 図 OUTLINE 000-802-080 M4 2 WASHER CODE NO. 000-864-937 05DZ-X-9502 FURUNO ELECTRIC CO .,LTD. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) A-9 付属品表 CODE NO. 005-959-720 TYPE FP05-05701 05EC-X-9502 -2 1/1 RB-8800 ACCESSORIES 名 称 NAME 番 号 NO. 4 SELF-TAPPING SCREW CODE NO. 3 000-864-937 4X20 SUS304 +トラスタッピンネジ ブラインドシール 用途/備考 REMARKS 4 WASHER CODE NO. 2 数量 Q'TY M4 ポリカワッシャー 1 型名/規格 DESCRIPTIONS 略 図 OUTLINE 000-805-687 05-086-1102-2 4 SEAL CODE NO. 100-281-282 05EC-X-9502 FURUNO ELECTRIC CO .,LTD. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) A-10 NAME OF PART OUTLINE ヒューズ 1 005-377-820 TYPE SP05-05501 SPARE PARTS LIST FOR SHIP NO. ITEM NO. CODE NO. U DWG. NO. OR TYPE NO. S 05EC-X-9301 -0 1/1 BOX NO. P SETS PER VESSEL E QUANTITY REMARKS/CODE NO. WORKING PER SET PER VES FGBO 15A AC125V SPARE 2 FUSE 000-549-014 MFR'S NAME FURUNO ELECTRIC CO.,LTD. DWG NO. 05EC-X-9301 (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 1/1 DOCUMENT 000-149-932 ** 000-809-270 ** IM*-56420-* *52-00101-* 005-371-850 CP05-10201 000-054-223 005-951-790 HS-2003 FP05-05510 005-377-820 SP05-05501 000-054-240 ** 1 1 Q'TY 1 1 1 1 1 FP05-05800 RC-8800S/D-N-75BG,RC8800S/D-A-75BG DESCRIPTION/CODE № (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) DISTRESS PROCEDURE 遭難通信要領書 OPERATOR'S GUIDE 操作要領書 OPERATOR'S MANUAL 取扱説明書 NAME OUTLINE RC-8800S/D-N-75BG、RC-8800S/D-A-75BG コ-ド番号末尾の[**]は、選択品の代表コードを表します。 CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL. INSTALLATION MANUAL 装備要領書 VHF/MF DISTRESS ALERT FLOW 遭難警報フロVHFMF* 図書 OUTLINE INSTALLATION MATERIALS ACCESSORIES SPARE PARTS UNIT INSTALLATION MATERIALS 工事材料 工事材料 HANDSET ハンドセット BRACKET FOR HANDSET ハンドセットハンガー組品 付属品 SPARE PARTS 予備品 予備品 VHF CONSOLE VHFコンソール ユニット NAME PACKING LIST 05EC-X-9861 000-149-935 000-149-934 ** TIC-56420-* 000-149-930 ** OS*-56420-* OM*-56420-* DESCRIPTION/CODE № 05EC-X-9861 -0 1/1 1 1 1 Q'TY A-11 1 番 号 NO. CABLE ASSY. ミニピン組品(1) 略 図 OUTLINE CODE NO. L-420 000-151-748 型名/規格 DESCRIPTIONS CP05-10201 TYPE 1 数量 Q'TY 1/1 05EC-X-9409 Used only Japan 用途/備考 REMARKS 05EC-X-9409 -0 FURUNO ELECTRIC CO .,LTD. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 名 称 NAME INSTALLATION MATERIALS 工事材料表 005-371-850 CODE NO. A-12 N A M E O U T L I N E INSTALLATION MATERIALS UNIT 005-371-670 CP05-10001 005-371-650 ** RC-8800-N DESCRIPTION/CODE № 05EC-X-9860 -0 (略図の寸法は、参考値です。 05EC-X-9860 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) コ-ド番号末尾の[**]は、選択品の代表コー ドを表します。 CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL. INSTALLATION MATERIALS 工事材料 工事材料 CONSOLE KIT コンソール組品 ユニット RC-8800-N/RC-8800-A PACKING LIST 1 1 Q'TY 1/1 A-13 ⇟ภ 01 %#$.'#55; 㩚㩐㩕㩩㩧⚵ຠ %#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ ⇛ޓޓ࿑ 176.+0' %1&'01 . %1&'01 &57$/2*:. ဳฬ㧛ⷙᩰ &'5%4+26+105 %2 6;2' ᢙ㊂ 3 6; '%: ↪ㅜ㧛⠨ 4'/#4-5 '%: 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 ฬޓޓ⒓ 0#/' +056#..#6+10/#6'4+#.5 Ꮏ᧚ᢱ %1&'01 A-14 0#/' &1%7/'06 %) 8%6(:%/ ,' %2 22 &'5%4+26+10%1&'ͳ '%: 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 '%: A-15 3 6; 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯 176.+0'&4#9+0) ,2'0 ᄖኸ࿑㧔⧷㧕 ࿑ᦠ 176.+0' +056#..#6+10/#6'4+#.5 70+6 219'4%#$.' (14&%/#+05 㔚Ḯ㩃㨺㩖㩨㩣㧰㧯↪ %#$.'#55; 㩃㨺㩖㩨㩣⚵ຠ Ꮏ᧚ᢱ 24+06'470+6 㩖㩩㩢㩧㩊 ࡙࠾࠶࠻ 22 㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀 Y. Hatai D-1 Y. Hatai D-2 Y. Hatai D-3 D-4 Y. Hatai Y. Hatai D-5 Y. Hatai D-6 This page is intentionally left blank. D-7 Y. Hatai D-8 Y. Hatai Mar.11'04 H.Hayashi D-9 D-10 D-11 Feb.02'05 D-12 D-13 Nov.28'03 D-14 D-15 Y. Hatai D-16 Y. Hatai D-17 D-18 Dec.26'03 D-19 Dec.26'03 Y. Hatai D-20 1 2 3 4 *2 *2 A 接続箱 JUNCTION BOX IF-8810 送受信機 TRANSCEIVER UNIT FM-8800D/S T/R用アンテナ ANTENNA FOR T/R IEC61162-1(NMEA)/REMOTE CH70 WR用アンテナ ANTENNA FOR CH70 WR +15VDC 1 +15VDC 2 +15VDC 3 +15VDC 4 N.C 5 N.C 6 TXD(H) 7 TXD(C) 8 RXD(H) 9 RXD(C) 10 *2 M-P-5 D-SUB 37P ANT 1 2 1 2 EXT.ALM_N 0V W-MIC1(H) W-MIC1(C) W-SP1(H) W-SP1(C) W-PTT1_N 0V 0V 0V 0V 0V 11 12 13 14 15 16 17 18 19 20 21 22 VDR AF(H) VDR AF(C) DATA_A DATA_B LINE OUT(H) LINE OUT(C) LINE IN(H) LINE IN(C) W-MIC2(H) W-MIC2(C) W-SP2(H) W-SP2(C) W-PTT2_N 0V F.GND 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 B HANDSET ハンドセット 1 2 3 4 5 6 7 8 HANDSET HS-2003 外部スピーカ EXT. SP S.GND PTT SW_N MIC(H) MIC(C) HS SP(H) HOOK SW_N +5V F.GND SPKR 1 2 2.8 m SP(H) SP(C) SEM-21Q *2 C *1 DPYC-1.5 100-115/ 200-230 VAC AC IN *1 DPYC-2.5 + 24VDC 24 VDC - IN AC/DC電源 AC-DC POWER SUPPLY PR-240-CE *2 DC + OUT - PE 保護アース IV-2sq. *1 24VDC 24 VDC RED BLK D RED 05S9371,3m 注記 *1)造船所手配。 15A *2)オプション。 *3)最大4台まで接続可能。 *4)ケーブルクランプで接地。 *5)終端のユニットでは内部で ジャンパー(J2, J3)をONにする。 *6)P: 撚り対線 *7)ノーマルクローズ、フローティング 最大80mA、耐圧≦50V。 NOTE *1. *2. *3. *4. *5. SHIPYARD SUPPLY OPTION Max. 4 sets GROUND THROUGH CABLE CLAMP. CONNECT JUMPERS (J2 & J3) ON TERMINATED REMOTE STATION. *6. P: TWISTED PAIR CABLE *7. NORMAL CLOSE, FLOATING, MAX80mA, WITHSTAND VOLTAGE ≦50V. BLK 24VDC(+) 24VDC(-) GND PRINTER STROBE_N D0 D1 D2 D3 D4 D5 D6 D7 ACK_N BUSY PE SELECT ALF_N ERROR_N INIT._N SLCT IN_N F.GND 0V F.GND F.GND F.GND F.GND F.GND F.GND P P P P P P P P P P P P P P P P P *2 D-SUB 25P 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 TXD(H) TXD(C) RXD(H) RXD(C) F.GND EXT.ALM_N *7 0V F.GND W-MIC1(H) W-MIC1(C) W-SP1(H) W-SP1(C) J2 W-PTT1_N 1 0V 2 F.GND 3 W-MIC2(H) 4 W-MIC2(C) 5 W-SP2(H) 6 W-SP2(C) 7 W-PTT2_N 8 0V 9 F.GND 10 VDR AF(H) 11 VDR AF(C) 12 NOT USED_1 NOT USED_2 J3 F.GND 1 +15VDC 2 0V 3 DATA_A 4 DATA_B 5 LINE IN(H) 6 LINE IN(C) 7 LINE OUT(H) 8 LINE OUT(C) 9 F.GND 10 N.C 11 +15VDC 12 0V 13 DATA_A 14 DATA_B LINE IN(H) LINE IN(C) LINE OUT(H) LINE OUT(C) F.GND N.C N.C 1 2 3 4 5 6 7 8 9 10 P CH70 RX ANT M-P-5 J1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 航法装置,プロッタ NAVIGATION DEVICE, PLOTTER RXD(H) RXD(C) TXD(H) TXD(C) *2 CO-SPEVV-SB-C *4 0.2X2P,φ10.5 キ YEL P ダイ ORG アカ RED P チャ BRN *1 TTYCS-1 MAX. 20m *4 *4 アカ Pキ クロ Pキ シロ Pキ RED YEL BLK YEL WHT YEL アカ Pキ クロ Pキ シロ Pキ RED YEL BLK YEL WHT YEL 17JE-23250-02,3m プリンタ*2 PRINTER VDR *4 *2 05S0309 P P P P 終端まで最大50m MAX. 50m TO LAST UNIT シロ(太) クロ(太) ミドリ アオ キ ダイ アカ チャ PP-510 *2 *2 Wing Mic マイクレセプタクルボックス MIC RECEPTACLE BOX RBD-VHF(B) ハンドセット HANDSET TB1 1 2 3 4 5 6 7 HS-6000FZ-11 HS-6000FZ-5 外部アラーム Ext. Alarm *1 1 2 3 4 キ シロ アカ キ クロ キ YEL WHT RED YEL BLK YEL 1 2 3 4 5 6 7 8 *4 シロ(太) P クロ(太) ミドリ P アオ キ P ダイ アカ P チャ WHT(BIG) BLK(BIG) GRN BLU YEL ORG RED BRN +15VDC 1 OV 2 DATA_A 3 DATA_B 4 LINE IN(H) 5 LINE IN(C) 6 LINE OUT(H) 7 LINE OUT(C) 8 TB3 WHT(BIG) BLK(BIG) GRN BLU RED BRN YEL ORG TB1 P P *4 アカ RED クロ BLK シロ WHT TB1 *4 11 12 13 14 17 18 15 16 F.GND 19 TXD(H) TXD(C) RXD(H) RXD(C) F.GND IV-1.25sq. *1 20 21 22 23 24 1 2 3 4 5 6 7 8 P P 4 YEL WHT RED YEL BLK YEL P P P ハンドセット *2 HANDSET HS-8800 リモートステーション 4 REMOTE STATION *2 RB-8800/RB-8810 DATA_A 1 *3 DATA_B 2 *5 CONT 3 DIST_SW 4 LINE OUT(H) 5 LINE I/O(C) 6 LINE IN(H) 7 +15V1 8 OV 9 F.GND 10 TB1 TB2 左と同じ Same as left TB3 TB3 TB3 IV-1.25sq. *1 リモートステーション REMOTE STATION *2 RB-8800/RB-8810 *3 *5 1 2 3 4 5 6 7 8 9 F.GND 10 N.C 24VDC リモートステーション 3 REMOTE STATION *2 RB-8800/RB-8810 DATA_A 1 *3 DATA_B 2 CONT 3 DIST_SW 4 LINE OUT(H) 5 LINE I/O(C) 6 LINE IN(H) 7 +15V1 8 OV 9 F.GND 10 TB1 TB2 IV-1.25sq. *1 DMC I/F *2 IF-8820 キ シロ アカ キ クロ キ 1 2 3 ハンドセット *2 HANDSET HS-8800 左と同じ Same as left IV-1.25 *1 MAX. 50m TO LAST UNIT 1 2 3 4 5 6 7 CO-SPEVV-SB-C 0.2x5P,φ13.5 MAX.20m *2 1 2 3 4 5 6 7 8 *2 05S0309 終端まで最大50m マイクレセプタクルボックス MIC RECEPTACLE BOX RBD-VHF(B) HS-6000FZ-11 HS-6000FZ-5 P リモートステーション 2 REMOTE STATION *2 RB-8800/RB-8810 DATA_A 1 *3 DATA_B 2 CONT 3 DIST_SW 4 LINE OUT(H) 5 LINE I/O(C) 6 LINE IN(H) 7 +15V1 8 OV 9 F.GND 10 TB2 TB1 シロ(太) Pクロ(太) ミドリ Pアオ アカ Pチャ キ Pダイ *2 ハンドセット HANDSET ハンドセット *2 HANDSET HS-8800 リモートステーション 1 REMOTE STATION *2 RB-8800/RB-8810 DATA_A 1 *3 DATA_B 2 CONT 3 DIST_SW 4 LINE OUT(H) 5 LINE I/O(C) 6 LINE IN(H) 7 +15V1 8 OV 9 F.GND 10 TB2 TB1 WHT(BIG) BLK(BIG) GRN BLU YEL ORG RED BRN VCTF0.75x3C,5m,φ7 + 1 - 2 GND 3 *2 Wing Mic ハンドセット *2 HANDSET HS-8800 TTYCS-1 MAX. 20m *1 S-1 6 CO-SPEVV-SB-C 0.2x5P,φ13.5 MAX. 20m *2 IV-1.25sq. *1 IV-1.25sq. *1 ハンドセット *2 HANDSET 上に同じ Same as HS-8800 above TB2 +15VDC OV DATA_A DATA_B 上に同じ LINE IN(H) Same as LINE IN(C) above LINE OUT(H) LINE OUT(C) TB3 IV-1.25sq.*1 ダイ ORG キ YEL チャ BRN アカ RED *1 CO-SPEVV-SB-C 0.2x2P(5/10/15/20/30m) 遭難警報装置 *2 DISTRESS MESSAGE CONTROLLER DMC-5 1 2 3 4 6 TB1/TB2 TXD(H) TXD(C) RXD(H) RXD(C) F.GND IV-1.25sq. *1 プリンタ*2 PRINTER VCTF0.75x2C,3m + 1 - 2 シロ WHT クロ BLK PP-8800 *1 IV-2sq. 5 IV-1.25sq. *1 24VDC DRAWN Jun. 9,'06 CHECKED APPROVED SCALE DWG No. E.MIYOSHI TAKAHASHI.T TITLE FM-8800D/S 名称 国際VHF無線電話装置 相互結線図 NAME VHF RADIOTELEPHONE INTERCONNECTION DIAGRAM Y. Hatai MASS C5642-C01- J kg FURUNO ELECTRIC CO., LTD. 3 M-P-5 M-P-5 ハンドセット HANDSET HS-2003 B 外部スピーカ EXT. SPEAKER SEM-21Q *2 1 2 1 2 1 2 3 4 5 6 7 8 φ3.5 2.8m ANT J1 IEC61162-1(NMEA)/REMOTE CH70 RX ANT J2 HANDSET S.GND PTT SW-N MIC-H MIC-C HS SP-H HOOK SW-N +5V F.GND SPKR SP-H SP-C GND C XM2A-3701 +15VDC 1 +15VDC 2 +15VDC 3 +15VDC 4 NC 5 NC 6 TXD-H 7 TXD-C 8 RXD-H 9 RXD-C 10 *1 非常灯 *2 EMERGENCY LAMP TB1 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 19 20 21 22 VDR AF-H VDR AF-C DATA-A DATA-B LINE OUT-H LINE OUT-C LINE IN-H LINE IN-C W_MIC2-H W_MIC2-C W_SP2-H W_SP2-C W_PTT2-N 0V F.GND 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 1 15A RED BLK 2 3 4 5 6 7 8 9 10 11 12 13 14 15 P P P P P W_MIC2-H W_MIC2-C W_SP2-H W_SP2-C W_PTT2-N 0V F.GND 16 17 18 19 20 21 22 VDR AF-H VDR AF-C J3 NOT USED_1 1 NOT USED_2 2 F.GND 3 4 +15VDC 5 0V 6 DATA-A 7 DATA-B 8 LINE IN-H 9 LINE IN-C 10 LINE OUT-H 11 LINE OUT-C 12 F.GND 13 NC 14 23 24 25 26 27 J2 EXT.ALM-N 0V W_MIC1-H W_MIC1-C W_SP1-H W_SP1-C W_PTT1-N 0V 0V 0V 0V 0V PRINTER 24VDC DPYC-2.5 TXD-C RXD-H RXD-C F.GND EXT.ALM-N *7 0V F.GND W_MIC1-H W_MIC1-C W_SP1-H W_SP1-C W_PTT1-N 0V F.GND J1 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 11 12 P P P P P P P P P P P P P D-SUB 25P 24VDC(+) 24VDC(-) 25 S1 1 2 3 1 ~ 36 J3 0V 24V J2 +15VDC 0V DATA-A DATA-B LINE IN-H LINE IN-C LINE OUT-H LINE OUT-C F.GND NC NC 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 TTYCS-4(*1) OR CO-SPEVV-SB-C 0.2x2P,φ10.5(*2) 航法装置/プロッタ NAVIGATOR PLOTTER P P *1 TTYCS-1,MAX.20m *2 CO-SPEVV-SB-C 0.2x5P, *4 φ13.5,MAX.20m アカ RED P キ YEL クロ BLK P キ YEL シロ WHT P キ YEL *2 *4 CO-SPEVV-SB-C 0.2x5P, φ13.5,MAX.20m アカ RED キ YEL クロ BLK キ YEL シロ WHT キ YEL *4 *1 TTYCS-1,MAX.20m *4 外部アラーム *1 EXTERNAL ALARM TB1 マイクレセプタクル 1 ボックス 2 MIC RECEPTACLE 3 BOX 4 RBD-VHF(B) *2 TB1 マイクレセプタクル 1 ボックス 2 MIC RECEPTACLE 3 BOX 4 RBD-VHF(B) *2 VDR *4 *2 05S0309 終端まで最長50m TOTAL 50m OR LESS TO TERMINATE シロ(太) クロ(太) ミドリ アオ アカ チャ キ ダイ P P P P WHT[B] BLK[B] GRN BLU RED BRN YEL ORG 1 2 3 4 5 6 7 8 *4 *2 05S0309 TOTAL 50m OR LESS TO TERMINATE シロ(太) クロ(太) ミドリ アオ アカ チャ キ ダイ P P P WHT[B] BLK[B] GRN BLU RED BRN YEL ORG *4 1 ~ 34 1 ~ 34 1 2 3 4 5 7 HS-6000FZ-11 HS-6000FZ-5 Wing Mic ハンドセット HANDSET *2 1 2 3 4 5 7 HS-6000FZ-11 HS-6000FZ-5 TB2 リモートステーション REMOTE STATION RB-8800/RB-8810*3 LINE IN-H LINE IN-C LINE OUT-H LINE OUT-C 1 2 3 4 5 6 7 8 *1 IV-1.25sq. 終端まで最長50m P Wing Mic ハンドセット HANDSET *2 TB1 1 DMC I/F 2 IF-8820 *2 3 4 5 6 7 8 9 F.GND F.GND 10 NC 11 12 13 14 15 16 17 18 19 TXD-H TXD-C RXD-H RXD-C F.GND 20 21 22 23 24 I/F 05P0541 J1 S-2 6 *6 ハンドセット HANDSET *2 1 2 3 4 5 6 7 8 9 10 A CH70 WR用アンテナ *2 ANTENNA FOR CH70 WR 接続箱 JUNCTION BOX IF-8810 TXD-H 1 送受信機 TRANSCEIVER UNIT FM-8800D/S 5 HS-8800 *2 05S0309 シロ(太) クロ(太) ミドリ アオ アカ チャ キ ダイ *2 05S0309 シロ(太) クロ(太) ミドリ アオ アカ チャ キ ダイ ハンドセット HANDSET *2 HS-8800 DATA-A DATA-B CONT DIST_SW LINE OUT-H LINE I/O-C LINE IN-H +15V1 OV F.GND T/R用アンテナ *2 ANTENNA FOR T/R 4 1 2 3 4 5 6 7 8 9 10 2 DATA-A DATA-B CONT DIST_SW LINE OUT-H LINE I/O-C LINE IN-H +15V1 OV F.GND 1 TB1 WHT[B] BLK[B] GRN BLU RED BRN YEL ORG 1 2 3 4 5 6 7 8 TB2 1 リモートステーション 2 REMOTE STATION RB-8800/RB-8810 3 4 *3 5 6 7 8 *5 リモートステーション REMOTE STATION RB-8800/RB-8810 *1 IV-1.25sq. 1 TB1 2 リモートステーション 3 REMOTE STATION RB-8800/RB-8810 4 *3 5 6 7 8 WHT[B] BLK[B] GRN BLU RED BRN YEL ORG ハンドセット HANDSET *2 HS-8800 *5 リモートステーション REMOTE STATION RB-8800/RB-8810 *1 IV-1.25sq. *2 CO-0.2x2P,5/10/15/20/30m P P *1 IV-1.25sq. 1 2 3 4 5 TB1/TB2 TXD-H TXD-C RXD-H RXD-C F.GND 遭難警報装置 DISTRESS MESSAGE CONTROLLER DMC-5 *1 IV-1.25sq. J2 プリンタ PRINTER UTP-80FK D *6 RACK CONSOLE 注記 *1)造船所手配。 *2)オプション。 *3)最大4台まで接続可能。 *4)ケーブルクランプで接地。 *5)終端ユニットは内部のジャンパー(J2,J3)をONにする。 *6)プリンタ有の場合 *7)ノーマルクローズ、フローティング、最大80mA、耐圧≦50V。 NOTE *1. *2. *3. *4. *5. *6. *7. SHIPYARD SUPPLY OPTION MAX. 4 SETS AVAILABLE GROUND THROUGH CABLE CLAMP. CONNECT JUMPERS (J2 & J3) ON TERMINATED REMOTE STATION. IN CASE OF "W/PRINTER" NORMAL CLOSE, FLOATING, MAX80mA, WITHSTAND VOLTAGE ≦50V. DRAWN Jun.9,'06 CHECKED APPROVED SCALE DWG No. E.MIYOSHI TAKAHASHI.T TITLE RC-8800 (FM-8800) 名称 国際VHF無線電話装置(ラック組込) 相互結線図 NAME VHF RADIOTELEPHONE (RACK CONSOLE) INTERCONNECTION DIAGRAM Y. Hatai MASS C5642-C02- D kg FURUNO ELECTRIC CO., LTD. 1 2 T/R用アンテナ ANTENNA FOR T/R CH70 WR用アンテナ ANTENNA FOR CH70 WR M-P-5 1 2 CH70 RX ANT M-P-5 1 2 B HANDSET ハンドセット 1 2 3 4 5 6 7 8 HANDSET HS-2003 S.GND PTT SW_N MIC(H) MIC(C) HS SP(H) HOOK SW_N +5V F.GND SPKR 1 2 2.8 m SP(H) SP(C) SEM-21Q *2 C 100-115/200-230 VAC 24 VDC *1 DPYC-1.5 *1 DPYC-2.5 + 24 VDC - IN *2 DC + OUT - PE 保護アース IV-2sq. *1 24 VDC 24 VDC 05S9371,3m RED 15A D BLK RED BLK 24 VDC(+) 24 VDC(-) 注記 *1)造船所手配。 *2)オプション。 *3)ケーブルクランプで接地。 *4)コネクタクランプで接地。 *5)ノーマルクローズ、フローティング 最大80mA、耐圧≦50V。 NOTE *1. *2. *3. *4. *5. SHIPYARD SUPPLY OPTION GROUND THROUGH CABLE CLAMP. GROUND THROUGH CONNECTOR CLAMP. NORMAL CLOSE, FLOATING, MAX80mA, WITHSTAND VOLTAGE ≦50V. EXT.ALM_N *5 0V F.GND 11 12 37 W-MIC1(H) W-MIC1(C) W-SP1(H) W-SP1(C) W-PTT1_N 0V F.GND 13 14 15 16 17 18 37 GND P P +15VDC 0V DATA_A DATA_B LINE IN(H) LINE IN(C) LINE OUT(H) LINE OUT(C) F.GND 1 19 25 26 27 28 29 30 37 W-MIC2(H) W-MIC2(C) W-SP2(H) W-SP2(C) W-PTT2_N 0V F.GND 31 32 33 34 35 36 37 STROBE_N D0 D1 D2 D3 D4 D5 D6 D7 ACK_N BUSY PE SELECT ALF_N ERROR_N INIT._N SLCT IN_N F.GND 0V F.GND F.GND F.GND F.GND F.GND F.GND *2 CO-SPEVV-SB-C 0.2X2P,φ10.5 キ YEL ダイ ORG アカ RED チャ BRN *4 P P P アカ キ クロ キ シロ キ *4 *4 P P P P *4 P P P P: 撚り対線 P: TWISTED PAIR CABLE P TB1 YEL WHT RED YEL BLK YEL 1 2 3 4 5 6 7 1 2 3 4 HS-6000FZ-11 HS-6000FZ-5 VDR WHT(BIG) BLK(BIG) GRN BLU YEL ORG RED BRN *2 05S0309 終端まで最大50m DMC I/F *2 IF-8820 MAX. 50m TO LAST UNIT RED YEL BLK YEL WHT YEL 1 2 3 4 5 6 7 8 9 F.GND 10 N.C *3 11 12 13 14 17 18 15 16 F.GND 19 TXD(H) TXD(C) RXD(H) RXD(C) F.GND *4 *2 D-SUB 25P 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 P キ シロ アカ キ クロ キ ハンドセット HANDSET *2 CO-SPEVV-SB-C 0.2x5P,φ13.5 MAX. 20m *2 TTYCS-1 MAX. 20m *1 アカ キ クロ キ シロ キ P 外部アラーム Ext. Alarm *1 RED YEL BLK YEL WHT YEL シロ(太) クロ(太) ミドリ アオ キ ダイ アカ チャ Wing Mic マイクレセプタクルボックス *2 MIC RECEPTACLE BOX RBD-VHF(B) *1 TTYCS-1 MAX. 20m 20 21 22 23 24 遭難警報装置 DISTRESS MESSAGE CONTROLLER DMC-5 P P ダイ ORG キ YEL チャ BRN アカ RED CO-SPEVV-SB-C 0.2x2P(5/10/15/20/30m),φ10.5 1 2 3 4 6 TB1/TB2 TXD(H) TXD(C) RXD(H) RXD(C) F.GND *2 IV-1.25sq. *1 CO-SPEVV-SB-C 0.2x5P,φ13.5 MAX. 20m *2 17JE-23250-02,3m プリンタ*2 PRINTER PP-510 VCTF0.75x3C,5m,φ7 + 1 - 2 GND 3 アカ RED クロ BLK シロ WHT 24VDC P P P VCTF0.75x2C,3m プリンタ*2 PRINTER + 1 - 2 シロ WHT クロ BLK IV-1.25sq. *1 E. MIYOSHI TAKAHASHI.T APPROVED Y. Hatai SCALE MASS DWG No. キ シロ アカ キ クロ キ YEL WHT RED YEL BLK YEL C5642-C03- D kg ハンドセット *2 HANDSET TB1 1 2 3 4 24VDC DRAWN Jun. 9,'06 CHECKED Wing Mic マイクレセプタクルボックス *2 MIC RECEPTACLE BOX RBD-VHF(B) IV-1.25sq. *1 PP-8800 *1 IV-2sq. S-3 6 航法装置,プロッタ NAVIGATION DEVICE, PLOTTER RXD(H) RXD(C) TXD(H) TXD(C) *4 VDR AF(H) 23 VDR AF(C) 24 F.GND 37 PRINTER AC/DC電源 AC-DC POWER SUPPLY PR-240-CE AC IN D-SUB 37P TXD(H) 7 TXD(C) 8 RXD(H) 9 RXD(C) 10 F.GND 37 ANT 5 *2 IEC61162-1(NMEA)/REMOTE *2 外部スピーカ EXT. SP 4 送受信機 TRANSCEIVER UNIT FM-8800D/S *2 A 3 1 2 3 4 5 6 7 HS-6000FZ-11 HS-6000FZ-5 TITLE FM-8800D/S 名称 国際VHF無線電話装置 相互結線図(接続箱無し) NAME VHF RADIOTELEPHONE INTERCONNECTION DIAGRAM(W/O J.B.) FURUNO ELECTRIC CO., LTD.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 69 Page Mode : UseOutlines Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:ca4175aa-caef-4110-b742-23ac21f5302e Producer : Acrobat Distiller 4.05 for Windows Create Date : 2004:03:11 15:10:34Z Modify Date : 2006:06:15 16:09:04+09:00 Metadata Date : 2006:06:15 16:09:04+09:00 Document ID : uuid:88c534af-493a-4181-8015-13f19761a199 Instance ID : uuid:daada42b-1e1a-4502-afe0-47cfae7d3154 Format : application/pdfEXIF Metadata provided by EXIF.tools