Futaba FRH-SD06TU Low Power Radio Modem User Manual Manual
Futaba Corporation Low Power Radio Modem Manual
Futaba >
Manual
Page i Fcc Notlce Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications, Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense, This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation Any unauthorized changes or modifications to this device not expressly approved by Futaba Corporation of America could void the user‘s authority to operate the device and possibly result in damage to the equipment and/or cause serious or fatal injuries to the operator or nearby personnel. This device is intended to be installed and used in accordance with the instructions contained in this manual Failure to comply With these instructions could vord the user’s authority to operate the device and possibly result in damage to the equipment and/or cause serious or tatal injuries to the operator or nearby personnel, @ luttaba Corporation of Amcntu kw. 990121 01 Page ii FRHSDOGTU Manual Important Safety Information The list of dangers, warnings and cautions in this section contain imponant information that will help ensure safe operation ofthe system. Please read carefully and understand all of these items. All installers, operators and maintenance personnel should read and understand this information before installation, use, or maintenance of the FRH system. The FRH system by itselfis not inherently dangerous. HOWEVERy WHEN THE FRH SYSTEM IS CONNECTED TO OTHER EQUIPMENT FOR THE PURPOSE OF CONTROL, SAFETY AND ALL POSSIBLE ASSOCIATED DANGERS MUST ALWAYS BE GIVEN THE UTMOST CONSIDERATION DURING SYSTEM INTEGRATION, DESIGN, INSTALLATION, AND IEE. The FRH system may be used in vinually unlimited applications. Many of these assocrated systems can, by themselves, pose a mechanical, electrical or other hamrd to operators and other persons or equipment. To address all possible applications and associated safety hazards in this manual would be impossible. The warnings below and throughout this manual give you intorrnation that Will allow you to install and use the FRH system safely in most applications, If you have questions regarding the safety of your specific application, please contact the appropriate people tor help. Your Futaba sales representative, representatives of the equipment you are controlling, and the technical suppon staff at Futaba Corporation of America are among those who can give you assistance with your safety concerns, The following warnings are included in the lists that follow but warrant repetition here: In installations where the FRH system is used to control motion oroperation of potentially dangerous equipment, it is imperative for safety that all operators and installers be thoroughly trained in the normal function of that equipment before attempting to control it remotely with the FRH system. To help ensure safe operation of the equipment, the FRH system must be connected so that it will operate in a fail-safe way. In other words, the equipment being controlled should stop or return to its safest state in the absence ofa control signal or total loss of RF transmission from the FRH modem, Our system uses one of the most reliable methods available to transmit data using radio signals. Many factors can affect a radio signal that may block it or interfere enough to disrupt regular transmission. Because of this, equipment motion or dangerous electrical current, for example, that continues during a loss-of—signal condition could be very dangerous. Futaba Rev. 9901214” Page iii Four symbols are used in the margin of the following section and throughout the manual to indicate the level ofhazard or information listed, The symbols are defined as follows: A NGER Indicates a hazard that will cause severe personal injury, death, or substantial property damage if the warning is ignored, Indicates a hazard that can cause severe personal injury, death, or substantial property damage if the warning is ignored, Indicates a hazard that will or can cause minor personal injury, or property damage if the warning is ignored. Indicates installation, operation, or maintenance information that is important but not hazard»related. Please read the following safety information carefully Some of these notices are duplicated throughout the manual, in areas of associated content, for your benefit General Safety Hazards and Notes Improper installation and/or operation of the FRH system can cause serious or fatal injuries to the operator or nearby persons and cause damage to the FRH system, and any equipment it is used to control, Please read and understand this manual completely and the manual of all equipment being controlled before attempting to operate or install this system. Always keep this manual at a location readily aceesstble to anyone operating the system and related equipment. Ensure that all operators have read and understood this manual, especially all safety and operation procedures contained in it, Please refer to the section in this manual titled How to Obtain Help for the contact that can supply you with additional manuals or for questions not covered in this manual. If this product is passed on to a different user, be sure that this manual accompanies the product. Be certain that the installer of this equipment reads and understands the instruction manual of the equipment that you are connecting to bctore attempting this installation.
Source Exif Data:File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res Creator : Create Date : Freitag, 21. Juli 2000 10:22 Title : Author : Producer : Acrobat PDFWriter 3.02 für Windows Subject : Modify Date : 2000:07:21 10:44:18 Page Count : 8EXIF Metadata provided by EXIF.tools