Download: | |
Mirror Download [FCC.gov] | |
Document ID | 3390422 |
Application ID | 8RspHY+2EVSTb0fOGsEdrg== |
Document Description | Users Manual |
Short Term Confidential | No |
Permanent Confidential | No |
Supercede | No |
Document Type | User Manual |
Display Format | Adobe Acrobat PDF - pdf |
Filesize | 193.28kB (2415973 bits) |
Date Submitted | 2017-05-15 00:00:00 |
Date Available | 2017-06-07 00:00:00 |
Creation Date | 2017-10-24 22:20:37 |
Producing Software | GPL Ghostscript 9.18 |
Document Lastmod | 2017-10-24 22:20:37 |
Document Title | Testreport ETS 300 335 |
Document Creator | Microsoft® Word 2016 |
Document Author: | Manfred Dudde |
Test report no. 17010782
EUT: WS100
Page 1 of 1
FCC ID: UF9WS100
FCC Title 47 CFR Part 15 C
Date of issue: 2017-04-28
Annex acc. to FCC Title 47 CFR Part 15
relating to
G. Lufft Mess- und Regeltechnik GmbH
WS100
Annex no. 5
User Manual
Functional Description
Title 47 - Telecommunication
Part 15 - Radio Frequency Devices
Subpart C – Intentional Radiators
ANSI C63.4-2014
ANSI C63.10-2013
Date: 2016-08-19
m. dudde hochfrequenz-technik
Created: P9
Rottland 5a
Controlled: P4
D-51429 Bergisch Gladbach/ Germany
Released: P1
Tel: +49 2207-96890
Vers. no. 2.16
Fax +49 2207-968920
48.7230-WSX-E
Document version V34 (03/2017)
© G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to make technical changes at any time without notice.
Operating Manual
Smart Weather Sensor
Contents
Please Read Before Use .............................................................................................................................................5
1.1
1.2
1.3
1.4
1.5
1.6
Symbols Used .....................................................................................................................................................5
Safety Instructions ...............................................................................................................................................5
Designated Use ...................................................................................................................................................5
Incorrect Use .......................................................................................................................................................5
Warranty ..............................................................................................................................................................5
Brand Names.......................................................................................................................................................5
Scope of Delivery ........................................................................................................................................................6
Order Numbers ............................................................................................................................................................7
3.1
3.2
3.3
Equipment Description .............................................................................................................................................10
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
Air Temperature and Humidity ...........................................................................................................................10
Air Pressure .......................................................................................................................................................11
Precipitation .......................................................................................................................................................11
Wet Bulb Temperature.......................................................................................................................................11
Specific Enthalpy ...............................................................................................................................................11
Air Density .........................................................................................................................................................11
Wind ..................................................................................................................................................................11
Compass ...........................................................................................................................................................11
Heating ..............................................................................................................................................................11
Global Radiation ................................................................................................................................................11
Lightning Sensor ................................................................................................................................................11
External Temperature Sensor............................................................................................................................11
External Rain Gauge .........................................................................................................................................12
(WS100-UMB only: ) Impulse Output for Rain Gauge Simulation ......................................................................12
Sensor Technology (example: WS600-UMB) ....................................................................................................13
Generation of Measurements ...................................................................................................................................14
5.1
5.2
5.3
5.4
Accessories .........................................................................................................................................................9
Spare Parts..........................................................................................................................................................9
Additional Documents and Software ....................................................................................................................9
Current Measurement (act)................................................................................................................................14
Minimum and Maximum Values (min and max) .................................................................................................14
Average Value (avg) ..........................................................................................................................................14
Vectorial Average Value (vct) ............................................................................................................................14
Measurement Output ................................................................................................................................................15
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
6.9
6.10
6.11
6.12
6.13
6.14
6.15
6.16
6.17
6.18
Air and Dewpoint Temperature ..........................................................................................................................15
Wind Chill Temperature .....................................................................................................................................15
Humidity.............................................................................................................................................................15
Air Pressure .......................................................................................................................................................15
Wet Bulb Temperature.......................................................................................................................................16
Specific Enthalpy ...............................................................................................................................................16
Air Density .........................................................................................................................................................16
Wind Speed .......................................................................................................................................................17
Wind Direction ...................................................................................................................................................17
Wind Measurement Quality ...............................................................................................................................18
Compass ...........................................................................................................................................................18
Precipitation Quantity - Absolute .......................................................................................................................19
Precipitation Quantity - Differential ....................................................................................................................19
Precipitation Intensity.........................................................................................................................................19
Precipitation Type ..............................................................................................................................................20
Heating Temperature .........................................................................................................................................20
Global Radiation ................................................................................................................................................20
Lightning Sensor ................................................................................................................................................21
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
6.19 Service Messages............................................................................................................................................. 21
6.20 Drop Diameter Distribution (WS100 only) ........................................................................................................ 22
Installation ................................................................................................................................................................ 23
7.1
7.2
7.3
Connections.............................................................................................................................................................. 27
8.1
8.2
8.3
8.4
8.5
8.6
Fastening .......................................................................................................................................................... 23
North Alignment ................................................................................................................................................ 24
Selecting the Installation Location..................................................................................................................... 25
Supply Voltage .................................................................................................................................................. 28
RS485 Interface ................................................................................................................................................ 28
Connection to ISOCON-UMB (8160.UISO) ...................................................................................................... 29
Use of Surge Protection (8379.USP) ................................................................................................................ 29
Connection of External Temperature and Precipitation Sensors ...................................................................... 29
(WS100-UMB only: ) Connection of Impulse Output for Rain Gauge Simulation .............................................. 29
Commissioning ........................................................................................................................................................ 30
10 Configuration and Test ............................................................................................................................................ 31
10.1
10.2
10.3
10.4
10.5
Factory Settings ................................................................................................................................................ 32
Configuration with the UMB-Config-Tool........................................................................................................... 32
Function Test with UMB-Config-Tool ................................................................................................................ 39
Operating Modes of the Smart Weather Sensor ............................................................................................... 40
Operating Modes for Equipment Heating .......................................................................................................... 42
11 Firmware Update ...................................................................................................................................................... 44
12 Maintenance.............................................................................................................................................................. 44
12.1 Maintenance of the Rain Gauge ....................................................................................................................... 45
13 Technical Data .......................................................................................................................................................... 46
13.1 Measuring Range / Accuracy ............................................................................................................................ 48
13.2 Drawings ........................................................................................................................................................... 51
14 EC Certificate of Conformity ................................................................................................................................... 63
14.1 WS100 FCC Compliance Statement (US) ........................................................................................................ 64
14.2 WS 100 IC Compliance Statement (CA) ........................................................................................................... 64
15 Fault Description ...................................................................................................................................................... 65
16 Disposal .................................................................................................................................................................... 66
16.1 Within the EC .................................................................................................................................................... 66
16.2 Outside the EC ................................................................................................................................................. 66
17 Repair / Corrective Maintenance ............................................................................................................................. 66
17.1 Technical Support ............................................................................................................................................. 66
18 External Sensor ........................................................................................................................................................ 67
18.1 External Temperature and Precipitation Sensors ............................................................................................. 67
19 Appendix ................................................................................................................................................................... 69
19.1
19.2
19.3
19.4
19.5
19.6
19.7
19.8
Channel List Summary...................................................................................................................................... 69
Channel List Summary per TLS2002 FG3 ........................................................................................................ 71
Communication in Binary Protocol .................................................................................................................... 72
Communication in ASCII Protocol ..................................................................................................................... 75
Communication in Terminal Mode .................................................................................................................... 78
Communication in SDI-12 Mode ....................................................................................................................... 81
Communication in Modbus Mode.................................................................................................................... 124
Communication: XDR Protocol ....................................................................................................................... 136
20 List of Figures......................................................................................................................................................... 148
21 Index ........................................................................................................................................................................ 149
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
Please Read Before Use
This manual is valid for devices of the Lufft WS family with device version 200 or
higher(2015), WS100-UMB with device version 010 (2017) or higher.Some functions or
features specified in this manual may not be available or may not be valid with older
device versions. The device version is indicated as the last number of the serial number,
e.g.: the device with SN: 063.1010.0701.021has the device version 21.
If you are using an older device of the WS family, please refer to the manual for device
versions up to 49 or for versions prior to 30 (www.lufft.com/en/support/downloads).
1.1
Symbols Used
Important information concerning potential hazards to the user
Important information concerning the correct operation of the equipment
1.2
Safety Instructions
Installation and commissioning must be carried out by suitably qualified
specialist personnel only.
Never take measurements on or touch live electrical parts.
Pay attention to the technical data and storage and operating conditions.
1.3
Designated Use
The equipment must only be operated within the range of the specified technical
data.
The equipment must only be used under the conditions and for the purposes for
which it was designed.
The safety and operation of the equipment can no longer be guaranteed if it is
modified or adapted.
1.4
Incorrect Use
If the equipment is installed incorrectly
It may not function.
It may be permanently damaged.
Danger of injury may exist if the equipment is allowed to fall.
If the equipment is not connected correctly
It may not function.
It may be permanently damaged.
The possibility of an electrical shock may exist.
1.5
Warranty
The Warranty period is 12 months from the date of delivery. The warranty is forfeited if the
designated use is violated.
1.6
Brand Names
All brand names referred to are subject without limitation to the valid trademark and
ownership rights of the respective owner.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
Scope of Delivery
Equipment
WS100-UMB
WS200-UMB
WS300-UMB
WS400-UMB
WS500-UMB
WS301-UMB
WS501-UMB
WS401-UMB
WS601-UMB
WS700-UMB
WS800-UMB
WS310-UMB
WS510-UMB
Connection cable 10m
Operating manual
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
WS600-UMB
Operating Manual
Smart Weather Sensor
Order Numbers
WS100-UMB
8367.U03 (Europe, USA, Canada)
Precipitation Radar
8367.U04 (UK)
Impulse Output for Raingauge Simulation
WS200-UMB
8371.U01
Wind Direction
Wind Speed
Compass
WS300-UMB
8372.U01
Air Temperature
Relative Humidity
Air Pressure
WS301-UMB
WS302-UMB
WS303-UMB
WS304-UMB
WS310-UMB
8374.U01
8374.U10
8374.U11
8374.U12
8374.U13
Air Temperature
Relative Humidity
Air Pressure
Global Radiation
WS400-UMB
8369.U01 (Europe, USA, Canada)
Precipitation Radar
8369.U02 (UK)
Air Temperature
Relative Humidity
Air Pressure
WS401-UMB
8377.U01
Precipitation Rain Gauge
Air Temperature
Relative Humidity
Air Pressure
WS500-UMB
8373.U01
Wind Direction
Wind Speed
Air Temperature
Relative Humidity
Air Pressure
Compass
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
WS501-UMB
WS502-UMB
WS503-UMB
WS504-UMB
WS510-UMB
8375.U01
8375.U10
8375.U11
8375.U12
8375.U13
Wind Direction
Wind Speed
Air Temperature
Relative Humidity
Air Pressure
Compass
Global Radiation
WS600-UMB
8370.U01 (Europe, USA, Canada)
Precipitation Radar
8370.U02 (UK)
Wind Direction
Wind Speed
Air Temperature
Relative Humidity
Air Pressure
Compass
WS601-UMB
8376.U01
Precipitation Rain Gauge
Wind Direction
Wind Speed
Air Temperature
Relative Humidity
Air Pressure
Compass
WS700-UMB
8380.U01 (Europe, USA, Canada)
Precipitation Radar
Wind Direction
Wind Speed
Air Temperature
Relative Humidity
Air Pressure
Compass
Global Radiation
WS800-UMB
8381.U01 (Europe, USA, Canada)
Precipitation Radar
Wind Direction
Wind Speed
Air Temperature
Relative Humidity
Air Pressure
Compass
Global Radiation
Lightning Sensor
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
3.1
Accessories
Power supply unit 24V/100VA
ISOCON-UMB
Surge protection
External Rain Gauge WTB100
External Temperature Sensors
Temperature Sensor WT1
Passive Road Surface Temperature Sensor WST1
3.2
Spare Parts
Connection cable 10m
8366.USV1
8160.UISO
8379.USP
8353.10
8160.WT1
8160.WST1
On enquiry
3.3
Additional Documents and Software
You can download the following documents and software via the Internet at www.lufft.com.
Operating Manual
This document
®
UMB-Config-Tool
Windows software for testing, firmware updates and
configuration of UMB devices
UMB Protocol
Communications protocol for UMB devices
Firmware
The current device firmware
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
Equipment Description
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
WS800-UMB
●
●
●
●
WS700-UMB
● ●
● ●
● ●
●*
●
●
●
WS601-UMB
WS401-UMB
●
●
●
●
WS600-UMB
WS400-UMB
●
●
●
WS501-UMB***
WS301-UMB**
●
●
●
WS500-UMB
WS300-UMB
Air temperature
Humidity
Air pressure
Precipitation
Wind direction
Wind speed
Compass
Global Radiation
Lightning Sensor
Temperature (ext)
Rain Gauge (ext)
Power Save 2
WS200-UMB
WS100-UMB
The WS family is a range of low cost smart combination of weather sensors for the
acquisition of a variety of measurement variables, as used for example for environmental
data logging in road traffic management systems. Depending on the model, each device has
a different combination of sensors for the various measurement variables.
●
●
●
●
●
●
●
●
●
●
●*
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
*) WS401-UMB and WS601-UMB use a rain gauge for precipitation measurement
**) is also valid for WS302-UMB, WS303-UMB, WS304-UMB, WS310-UMB
***) is also valid for WS502-UMB, WS503-UMB, WS504-UMB, WS510-UMB
Sensors marked (ext) in the table are additional accessories and not included with the
device. The table shows which external sensors can be connected to the different models.
Note: The external temperature sensor and the external rain gauge use the same input, so
only one of them can be connected simultaneously.
Attention: Please note that, due to the approval of the radar sensor used, there are different
country options on equipment which includes precipitation measurement by radar
technology.
The equipment is connected by way of an 8 pole screw connector and associated
connection cable (length 10m).
The measured values are requested over the RS485 interface in accordance with UMB
protocol.
During commissioning, configuration and measurement polling takes place using the UMB®
Config-Tool (Windows PC software) or the ConfigTool.NET (for WS100-UMB)
4.1
Air Temperature and Humidity
Temperature is measured by way of a highly accurate NTC-resistor while humidity is
measured using a capacitive humidity sensor. In order to keep the effects of external
influences (e.g. solar radiation) as low as possible, these sensors are located in a ventilated
housing with radiation protection. In contrast to conventional non-ventilated sensors, this
allows significantly more accurate measurement during high radiation conditions.
WS100-UMB is not intended for air temperature measurement, so it is not equipped with a
radiation shield. Air temperature values with reduced accuracy are available as service
channels for additional information.
Additional variables such as dewpoint, absolute humidity and mixing ratio are calculated
from air temperature and relative humidity, taking account of air pressure.
10
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
4.2
Air Pressure
Absolute air pressure is measured by way of a built-in sensor (MEMS). The relative air
pressure referenced to sea level is calculated using the barometric formula with the aid of
the local altitude, which is user-configurable on the equipment.
4.3
Precipitation
Tried and tested radar technology from the R2S-UMB sensor is used to measure
precipitation. The precipitation sensor works with a 24GHz Doppler radar, which measures
the drop speed and calculates precipitation quantity and type by correlating drop size and
speed.
WS401-UMB and WS601-UMB are using an unheated rain gauge for precipitation
measurement. This version can be recommended for low power application etc.
4.4
Wet Bulb Temperature
The wet bulb temperature is the temperature of a moist or icy surface exposed to air flow.
4.5
Specific Enthalpy
Parameter of state of the humid air, composed of the specific enthalpies (heat capacity) of
the components of the mixture and related to the mass fraction of the dry air (at 0°C).
4.6
Air Density
The air density indicates how much mass in a given volume of air is contained and it is
calculated from the measured values of air temperature, humidity and air pressure.
4.7
Wind
The wind meter uses 4 ultrasonic sensors which take cyclical measurements in all directions.
The resulting wind speed and direction are calculated from the measured run-time sound
differential. The sensor delivers a quality output signal indicating how many good readings
were taken during the measurement interval.
4.8
Compass
The integrated electronic compass can be used to check the north – south adjustment of the
sensor housing for wind direction measurement. It is also used to calculate the compass
corrected wind direction.
4.9
Heating
The precipitation sensor and wind meter are heated for operation in winter.
4.10 Global Radiation
The global radiation is measured by a pyranometer mounted in the top cover of the Smart
Weather Sensor.
4.11 Lightning Sensor
WS800-UMB includes lightning detection by an integrated sensor analysing the radio wave
emission of lightnings. It delivers a count of recognized lightnings.
The sensor analyses spectrum and wave form of the received signal to suppress the
detection of man made electrical discharges. Nevertheless false detections can not be totally
excluded specially in an environment with high power electrical equipment.
4.12 External Temperature Sensor
Optionally all models may be equipped with an external NTC temperature sensor for the
acquisition from additional measurement points. The type of NTC is the same as used for the
internal air temperature sensor.
External temperature sensor and external rain gauge can not be connected at the same
time.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
11
Operating Manual
Smart Weather Sensor
4.13 External Rain Gauge
Models without integrated precipitation acquisition can be equipped with an external rain
gauge.
External rain gauge and external temperature sensor can not be connected at the same
time.
4.14 (WS100-UMB only: ) Impulse Output for Rain Gauge Simulation
WS100-UMB provides a digital impulse output for simulation of a rain gauge. Depending on
configuration settings the output is pulsed once for each 1.0mm, 0.1mm or 0.01mm (default)
of precipitation.
If the WS100-UMB is configured for impulse output, the serial interface is not available for
communication in UMB or other serial protocols.
12
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
4.15 Sensor Technology (example: WS600-UMB)
Precipitation sensor
(heated)
Wind meter
(heated)
Air pressure sensor in
device
Air temperature and relative
humidity with fan on underside
of device
Connector
Mounting bracket with
springs and self-locking nuts
Notch for attaching
connection cable
Figure 1: Sensor
Technology
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
13
Operating Manual
Smart Weather Sensor
Generation of Measurements
5.1
Current Measurement (act)
In accordance with the specified sampling rate, the value of the last measurement is
transmitted when the current measurement value is requested. Each measurement is stored
in a circular buffer for the subsequent calculation of minimum, maximum and average
values.
5.2
Minimum and Maximum Values (min and max)
When requesting the minimum and maximum values, the corresponding value is calculated via the circular buffer at the interval (1 – 10 minutes) specified in the configuration - and
transmitted.
Note: In the case of wind direction, the minimum / maximum value indicates the direction at
which the minimum / maximum wind speed was measured.
5.3
Average Value (avg)
When requesting the average value, this is calculated - via the circular buffer at the interval
(1 – 10 minutes) specified in the configuration - and transmitted. In this way moving
averages can also be calculated.
For some values the standard deviation is calculated for the same interval. The calculation of
standard deviation will only be activated after the related UMB channel has been requested
for the first time.
5.4
Vectorial Average Value (vct)
In the specific case of wind measurement, measurements are calculated vectorially. To this
end, the average values of the vectors are generated internally. This calculation is performed
with the same configured interval time as that for the minimum, maximum and average
values. Hence the value (wind speed) and angle (wind direction) of the vector are calculated.
Note: On delivery, the interval for the calculation of minimum, maximum and average values
is set at 10 minutes. If necessary, this can be adjusted to the particular requirements (1 – 10
minutes) with the aid of the UMB-Config-Tool (see page 31).
Note: The evaluation of the standard deviation values is deactivated after power on of the
device. The function will be activated with the first request to any of the standard deviation
channels.
To get standard deviation values of the first integration period after power on a dummy
request to any one of the standard deviation channels should be inserted.
14
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
Measurement Output
Measurements are transmitted in accordance with UMB binary protocol (Factory Settings).
You can find an example of a measurement request in different protocols and a complete
summary of the list of channels in the Appendix.
6.1
Air and Dewpoint Temperature
Sampling rate
1 minute
Generation of average value
1 – 10 minutes
Units
°C; °F
Request channels:
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float32)
min
max
unit
100
120
140
160
Air temperature
-50.0
60.0
°C
105
125
145
165
Air temperature
-58.0
140.0
°F
110
130
150
170
Dewpoint temperature
-50.0
60.0
°C
115
135
155
175
Dewpoint temperature
-58.0
140.0
°F
101
External Temperature Sensor
-40.0
80.0
°C
106
External Temperature Sensor
-40.0
176.0
°F
6.2
Wind Chill Temperature
Sampling rate
1 minute, computed on base of the average temperature
and average wind speed
Units
°C; °F
Request channels:
UMB Channel
act
min
max
Measuring Range
avg
Measurement Variable (float32)
min
max
unit
111
Wind chill temperature
-60.0
70.0
°C
116
Wind chill temperature
-76.0
158.0
°F
6.3
Humidity
Sampling rate
Generation of average value
Units
Request channels:
1 minute
1 – 10 minutes
%RH; g/m³; g/kg
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float32)
min
max
200
220
240
260
Relative humidity
0.0
100.0
205
225
245
265
Absolute humidity
0.0
1000.0
g/m³
210
230
250
270
Mixing ratio
0.0
1000.0
g/kg
6.4
Air Pressure
Sampling rate
Generation of average value
Unit
Request channels:
unit
1 minute
1 – 10 minutes
hPa
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float32)
min
max
unit
300
320
340
360
Absolute air pressure
300
1200
hPa
305
325
345
365
Relative air pressure
300
1200
hPa
Note: For the correct calculation of relative air pressure, the altitude of the sensor must be
entered in the device configuration (see Figure 11 on page 34). The factory setting for
altitude is 0m; in this way both measurement variables deliver the same values.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
15
Operating Manual
Smart Weather Sensor
6.5
Wet Bulb Temperature
Sampling rate
1 minute
Units
°C; °F
Request channels:
UMB Channel
Measuring Range
act
Measurement Variable (float32)
min
max
unit
114
Wet Bulb Temperature
-50.0
60.0
°C
119
Wet Bulb Temperature
-58.0
140.0
°F
act
Measurement Variable (float32)
min
max
unit
215
Specific Enthalpy
-100.0
1000.0
kJ/kg
act
Measurement Variable (float32)
min
max
unit
310
Air Density
0.0
3.0
kg/m³
6.6
Specific Enthalpy
Sampling rate
1 minute
Unit
kJ/kg
Request channels:
UMB Channel
6.7
Air Density
Sampling rate
Unit
Request channels:
Measuring Range
1 minute
kg/m³
UMB Channel
16
Measuring Range
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
6.8
Wind Speed
Sampling rate
1 sec / 10 sec (internal sampling frequency 15Hz)
Generation of average value
1 – 10 minutes
Generation of maximum value 1 – 10 minutes based on the internal second
measurements
Units
m/s; km/h; mph; kts
Response threshold
0.3 m/s
Request channels:
UMB Channel
Measuring Range
act
min
max
avg
vct
Measurement Variable (float32)
min
max
unit
400
420
440
460
480
Wind Speed
75.0
m/s
405
425
445
465
485
Wind Speed
270.0
km/h
410
430
450
470
490
Wind Speed
167.8
mph
415
435
455
475
495
Wind Speed
145.8
kts
401
Wind Speed Fast
75.0
m/s
406
Wind Speed Fast
270.0
km/h
411
Wind Speed Fast
167.8
mph
416
Wind Speed Fast
145.8
kts
403
Wind Speed Standard Deviation *
75.0
m/s
413
Wind Speed Standard Deviation *
167.8
mph
Note: The second measurements are averaged over 10 seconds for the output of the current
(act) measurement. The 'fast' channels deliver every second a value.
6.9
Wind Direction
Sampling rate
1 sec / 10 sec (internal sampling frequency 15Hz)
Generation of average value
1 – 10 minutes
Generation of maximum value 1 – 10 minutes based on the internal second
measurements
Unit
°
Response threshold
0.3 m/s
Request channels:
UMB Channel
act
min
max
500
520
540
avg
Measuring Range
vct
Measurement Variable (float32)
min
max
unit
580
Wind Direction
359.9
°
501
Wind Direction Fast
359.9
°
502
Wind Direction Corrected
359.9
°
503
Wind Dir. Standard Deviation *
359.0
°
Note: The second measurements are averaged over 10 seconds for the output of the current
(act) measurement. The 'fast' channels deliver every second a value.
The minimum / maximum wind direction indicates the direction at which the minimum /
maximum wind speed was measured.
The corrected wind direction is calculated from the wind direction measured by the wind
sensor and the heading measured by the compass.
Optionally the compass correction of the wind direction can be activated for all wind direction
values. (Settings by UMB Config Tool)
Note: The correction function is designed for correction of the wind direction of a statically
mounted sensor. If the alignment of the sensor changes during the measurement (i.e. if the
sensor is mounted on a rotating platform or similar) the correction function will not in all
cases work properly, especially not for the vector average.
It is of course possible to use the correction function for mobile measurement units, where
the alignment is changed between measurement periods.
*) Note: The evaluation of the standard deviation values will be activated after the first
request of a standard deviation channel. Please see p. 11.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
17
Operating Manual
Smart Weather Sensor
6.10 Wind Measurement Quality
Sampling rate
10 seconds
Unit
Request channels:
UMB Channel
act
min
max
avg
Measuring Range
vct
Measurement Variable (float32)
min
max
unit
805
Wind Value Quality
100
806
Wind Value Quality (fast)
100
Note: The value is updated every 10 seconds and transmits the minimum wind
measurement quality for the last 10 seconds interval.
The “fast” value indicates the measurement quality of the one second measurement value.
This value allows the user to assess how well the measurement system is functioning in the
respective ambient conditions. In normal circumstances the value is 90 - 100%. Values up to
50% do not represent a general problem. If the value falls towards zero the measuring
system is reaching its limits.
If during critical ambient conditions the system is no longer able to conduct reliable
measurements, error value 55h (85d) is transmitted (device unable to execute valid
measurement due to ambient conditions).
6.11 Compass
(only device version 030 or higher)
Sampling rate:
5 min
Unit
°
Request channels:
UMB Channel
act
min
510
max
avg
Measuring Range
vct
Measurement Variable (float)
min
max
unit
Compass Heading
359
°
Note: Reliable operation of the compass is only possible, if the sensor has been mounted
according to the instructions in this manual, i.e. on top of the pole. Should the sensor be
mounted on a traverse, the distribution of iron masses will be different from the situation
during factory calibration. This may lead to additional deviation of the bearing. This also
applies to lightning rods mounted at the pole top!
Dependent on the location of the installation the local declination of the earth magnetic field
has to be considered. The declination value is entered using the UMB-Config-Tool (see page
34). The declination for the installation location can be found in the Internet, e.g. at
http://www-app3.gfz-potsdam.de/Declinationcalc/declinationcalc.html
http://www.ngdc.noaa.gov/geomagmodels/Declination.jsp
Note: When the fan is not rotating the compass measurement value will be influenced by the
magnetic field of the fan. Normally the compass measurement will be performed with the fan
rotating to compensate this influence. If, starting from device version 037, the fan will not be
switched on in case of low operating voltage (less than 12V) deviations of the compass
measurement value must be accepted.
Note: When the device is operated in Power Saving Mode 1 or 2 the compass measurement
is performed only once after power on. Later changes of the orientation of the device will not
be recognized.
18
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
6.12 Precipitation Quantity - Absolute
Sampling rate
Event-dependent on reaching the response threshold
Response threshold
0.01mm (Radar)
Response threshold
0.2 / 0.5 mm (Rain Gauge)
Units
l/m²; mm; in; mil
Request channels:
UMB Channel
Measurement Variable (float32)
Unit
600
Precipitation Quantity - Absolute
l/m²
620
Precipitation Quantity - Absolute
mm
640
Precipitation Quantity - Absolute
in
660
Precipitation Quantity - Absolute
mil
Note: This measurement indicates the accumulated precipitation quantity since the last
device reboot. The measurement is retained for the duration of a short power failure. To
reset this value, use the corresponding function in the UMB-Config-Tool (see page 37) or
disconnect the device from the power supply for at least one hour.
6.13 Precipitation Quantity - Differential
Sampling rate
Event-dependent on reaching the response threshold
Response threshold
0.01mm (Radar)
Response threshold
0.2 / 0.5 mm (Rain Gauge)
Units
l/m²; mm; in; mil
Request channels:
UMB Chanel
Measurement Variable (float32)
Unit
605
Precipitation Quantity - Differential
l/m²
625
Precipitation Quantity - Differential
mm
645
Precipitation Quantity - Differential
in
665
Precipitation Quantity - Differential
mil
Note: Each request from a differential channel sets the accumulated quantity back to zero. If
the response from the device is lost due to a transmission error (e.g. poor GPRS
connection), the quantity accumulated to date is also lost. The quantity accumulated to date
is also reset each time the equipment is rebooted.
6.14 Precipitation Intensity
Sampling rate
1 minute
Response threshold
0.1 mm/h
Units
l/m²/h; mm/h; in/h; mil/h
Request channels:
UMB Channel
Measurement Variable (float32)
Range
Unit
800
Precipitation Intensity
0 … 200.0
l/m²/h
820
Precipitation Intensity
0 … 200.0
mm/h
840
Precipitation Intensity
0 … 7.874
in/h
860
Precipitation Intensity
0 … 7874
mil/h
Note: The device versions with radar technology (WS100-UMB, WS400-UMB, WS600-UMB,
WS700-UMB, WS800-UMB) calculate the precipitation intensity from the accumulated
precipitation differences of the last 6 minutes before the measurement data request.
The lower resolution of the rain gauge would lead to high fluctuation of the intensity values,
so the rain gauge versions (WS401-UMB and WS601-UMB), as well as the external rain
gauge, use the accumulated precipitation of the last 60 minutes prior to the current
measurement for intensity calculation.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
19
Operating Manual
Smart Weather Sensor
6.15 Precipitation Type
Sampling rate
Event-dependent on reaching the response threshold
Response threshold
0.002mm (Radar)
Response threshold
0.2 / 0.5 mm (Rain Gauge)
Follow-up time
2 minutes
Request channels:
UMB Channel
Measurement Variable (uint8)
Coding
Precipitation Type
0 = No precipitation
60 = Liquid precipitation, e.g. rain
70 = Solid precipitation, e.g. snow
40 = unspecified precipitation
(WS401-UMB, WS601-UMB, external
rain gauge)
WS100-UMB only:
67 = freezing rain
69 = sleet
90 = hail
700
Note: A detected precipitation type remains valid for 2 minutes after the end of the
precipitation event. In order to record precipitation types which only occur for a short period
(e.g. short-term rain), the request interval should be 1 minute or shorter.
Ice, hail and sleet are transmitted as rain (60) by devices other than WS100-UMB.
The versions WS401-UMB and WS601-UMB as well as the external rain gauge do not
include detection of precipitation type, so in this case only type 40 (unspecified precipitation)
is indicated. Due to the function of the rain gauge only liquid or molten precipitation can be
recognized.
6.16 Heating Temperature
Sampling Rate
1 Minute
Units
°C; °F
Request Channels:
UMB Channel
act
min
max
Measuring Range
Measurement Variable (float32)
min
max
Unit
112
avg
Heating Temperature Wind Sensor
-50.0
150.0
°C
113
Heating Temperature Precipitation Sensor
-50.0
150.0
°C
117
Heating Temperature Wind Sensor
-58.0
302.0
°F
118
Heating Temperature Precipitation Sensor
-58.0
302.0
°F
6.17 Global Radiation
Sampling Rate
Generation of average values
Unit
Request Channels:
10 seconds
1 – 10 minutes *)
W/m²
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float32)
900
920
940
960
Global Radiation
*) Until device version .49 / .212 / Firmware v5.6: 1400.0 W/m
min
max
unit
0.0
2000.0 *)
W/m²
*) Note: The average, maximum and minimum values are evaluated from the 1 minute
averages of the 10 second spot value.
When operated in Power Saving Mode 1 (see page 40) the WS700-UMB will measure the
global radiation only once per minute.
20
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
6.18
Lightning Sensor
6.18.1 Lightning Events
Sampling Rate 1 minute
Sum
1 – 30 minutes
Unit
Events
Request Channels:
UMB Channel
act
Measuring Range
sum
617
677
Measurement Variable (uint16)
min
max
unit
Lightning Events
255
Lightning Events (Interval)
7650
6.19 Service Messages
Service channels are available for the surveillance of the operation of the Smart Weather
Sensor.
Request Channels:
UMB Channel
act
min
max
Measuring Range
avg
Measurement Variable (float32)
min
max
unit
10000
Supply Voltage V
0.0
50.0
11000
Rain Drop Volume µ
0.0
500.0
µl
WS100-UMB only: Air temperature (without radiation shield)
Sampling rate
Generation of average value
Units
Request channels:
1 minute
1 – 10 minutes
°C; °F
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float32)
min
max
unit
4100
4120
4140
4160
Air temperature
-50.0
60.0
°C
4105
4125
4145
4165
Air temperature
-58.0
140.0
°F
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
21
Operating Manual
Smart Weather Sensor
6.20
Drop Diameter Distribution (WS100 only)
Drop diameters of precipitation detected by the radar sensor are shown as distribution of
drop diameter classes. Diameters are calculated as volume equivalent ball diameter.
Sampling Rate
Unit
Abfragekanäle:
Event dependent
Number of events
UMB Channel
Measurement Variable (uint32)
Unit
4600
Total precipitation particles
Events
4601
Total drops
Events
UMB Channel
Measurement Variable (uint16)
Unit
4602
Drizzle particles
Events
4603
Snow particles
Events
4604
Hail particles
Events
4620
Cl. 0: Drops < 0.5mm equiv. diameter
Events
4621
Cl 1: Drops 0.5 .. 1.0mm equiv. diameter
Events
4622
Cl 2: Drops 1.0 .. 1.5mm equiv. diameter
Events
4623
Cl 3: Drops 1.5 .. 2.0mm equiv. diameter
Events
4624
Cl 4: Drops 2.0 .. 2.5mm equiv. diameter
Events
4625
Cl 5: Drops 2.5 .. 3.0mm equiv. diameter
Events
4626
Cl 6: Drops 3.0 .. 3.5mm equiv. diameter
Events
4627
Cl 7: Drops 3.5 .. 4.0mm equiv. diameter
Events
4628
Cl 8: Drops 4.0 .. 4.5mm equiv. diameter
Events
4629
Cl 9: Drops 4.5 .. 5.0mm equiv. diameter
Events
4630
Cl 10: Drops 5.0 .. 5.5mm equiv. diameter
Events
4631
Cl 11: Drops > 5.5mm equiv. diameter
Events
Note: Similar to the request of differential precipitation quantity the accumulated sum of
events of each channel will be reset to 0 after transmission!
For consistent results all related channels should be requested in one run.
If the response from the device is lost due to a transmission error (e.g. poor GPRS
connection), the quantity accumulated to date is also lost. The quantity accumulated to date
is also reset each time the equipment is rebooted.
22
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
Installation
The sensor bracket is designed to be installed on the top of a mast with a diameter of 60 –
76mm.
The following tools are required for the installation:
Open-end or ring spanner (SW13)
Compass for aligning the wind meter to the North
7.1
Fastening
Springs
Nuts with washers
Mounting bracket
Mast tube
Figure 2: Fastening to
the Mast
Loosen nuts
Push the sensor onto the top of the mast from above
Tighten the nuts evenly until contact is made with the springs but the sensor can still be
moved easily
Align the sensor to the North (for wind meters)
Tighten both nuts with 3 revolutions
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
23
Operating Manual
Smart Weather Sensor
7.2
North Alignment
In order for the wind direction to display correctly, the
sensor must be aligned to the North. The sensor has a
number of directional arrows for this purpose.
Figure 3: North
Markings
Procedure:
If the sensor is already installed, first loosen both nuts evenly until you can turn the sensor
easily
Using the compass, identify the North and fix a point of reference on the horizon
Position the sensor in such a way that the South and North wind sensors are in alignment
with the fixed point of reference in the North
Tighten both nuts with 3 revolutions
Point of reference in the North
Figure 4: Alignment to
North
24
poor
good
Note: As the magnetic North Pole indicated by the compass differs from the Geographic
North Pole, account must be taken of the declination (variation) at the location when aligning
the sensor.
Depending on the location, the variation can be more than 15° (in North America for
example). In Central Europe the variation can be largely ignored at present (< 3°). You can
find further helpful information on this subject on the Internet.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
7.3
Selecting the Installation Location
In order to guarantee long service life and correct equipment operation, please pay attention
to the following points when selecting the installation location.
7.3.1
General Instructions
Stable subsurface for installing the mast
Free access to the equipment for maintenance works
Reliable power supply for permanent operation
Good network coverage when transmitting over a mobile communications network
Note: The computed measurements specifically apply to the equipment location only. No
conclusions can be drawn with regard to the wider environment or a complete road section.
ATTENTION:
Only approved and tested appliances (conductors, risers etc.) should be used to install the
device on the mast.
All relevant regulations for working at this height must be observed.
The mast must be sized and anchored appropriately.
The mast must be earthed in accordance with regulations.
The corresponding safety regulations for working at road side and in the vicinity of the
road carriageway must be observed.
If the equipment is installed incorrectly
It may not function.
It may be permanently damaged.
Danger of injury may exist if the equipment is allowed to fall.
7.3.2
Sensors with Wind Measurement / Compass
Installation at the top of the mast
Installation height at least 2m above the ground
Free field around the sensor
Note: Buildings, bridges, embankments and trees may corrupt the wind measurement.
Equally, passing traffic may cause gusts which may influence the wind measurement.
Note: for accurate compass readings, an aluminium mast is recommended.
7.3.3
Sensors with Radar Precipitation Measurement
Installation on the top of the mast
Installation height at least 4.5m above the ground
Distance to road carriageway at least 10m
Distance from moving objects (e.g. trees, bushes and even bridges) at least 10m at the
height of the sensor
Note: Falling or moving objects, e.g. falling leaves or leaves blowing in the wind, may cause
false measurements and/or precipitation types.
Note: Strong wind can influence the accuracy of the precipitation measurement.
Note: When selecting the installation location please take care to position the device at a
suitable distance from other systems incorporating a 24GHz radar sensor, such as traffic
counting devices on overhead gantry signs. Otherwise cross effects and system
malfunctions may occur. In the final analysis, the distance to other measuring systems also
depends on their range of coverage and signal strength.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
25
Operating Manual
Smart Weather Sensor
7.3.4
Sensors with Rain Gauge
Installation on the top of the mast or on crossbar with distance to the mast
Mast or crossbar mounting shall be exactly perpendicular, otherwise the precision of the
rain gauge may be influenced.
Note: The location should be selected so that pollution of the rain gauge funnel by falling
leaves etc. can be avoided as far as possible.
7.3.5
Sensors with Global Radiation Measurement
Installation on top of the pole
Shadow free location, if possible 360° free view to the horizon at the height of the
pyranometer
Distance to shadow casting objects (trees, buildings) at least 10 times of the object height
relative to the sensor.
7.3.6
Installation Sketch
Example WS600-UMB:
WS600-UMB
min. 5 m
Tree, bush
etc.
Mast
min. 4.5 m
min. 1 m
Figure 5: Installation
Sketch
26
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Road
carriageway
Operating Manual
Smart Weather Sensor
Connections
There is an 8 pole screw connector on the underside of the equipment. This serves to
connect the supply voltage and interfaces by way of the supplied connection cable.
Equipment connector:
Figure 6: Connections
View on sensor connection
Pin assignment:
White
Supply voltage ground and (SDI12_GND for device version > 41)
Brown
Positive supply voltage (through 2.5A fuse where required)*
Green
RS485_A (+) or (SDI-12 GND for device version < 42)
Yellow
RS485_B (-) or SDI-12 Data Line
Grey
External Sensor a
(WS100-UMB only: impulse output Uout)
Pink
External Sensor b
(WS100-UMB only: not connected)
Blue
Heating voltage ground
Red
Positive heating voltage (through 2.5A fuse where required)*
The cable marking is in accordance with DIN 47100.
*) WS100/400/600/700/800-UMB: Supply voltage and heating voltage shall be protected
by a fuses 2.5A (fast) each.
The cable shielding shall be connected to earth in the electrical cabinet.
Note: The yellow protective cap must be removed before plugging in the equipment.
If the equipment is not connected correctly
- It may not function
- It may be permanently damaged
- The possibility of an electrical shock may exist
The supply voltage and the heating voltage are protected against polarity reversal.
Note: When operating the Smart Weather Sensor in SDI12 mode, line 3 (green) shall be
connected only if the SDI12 logger is DC-isolated from the supply voltage of the device. If
signal ground (SDI-12-GND) of the data logger and power supply ground are identical, only
the SDI12-Data-Line (line 4, yellow) may be connected.
Note for SDI12 operation of devices starting from device version 42 or 51 (WS700): If
data logger and device supply voltage are DC-isolated the signal ground (SDI12_GND) must
be connected to line 1 (white). Line 3 (green) shall not be connected. (see SDI12
connection drawings in chapter 19.6)
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
27
Operating Manual
Smart Weather Sensor
8.1
Supply Voltage
The supply voltage for the Smart Weather Sensor is 12 - 24V DC. The power supply unit
used must be approved for operation with equipment of protection class III (SELV).
Starting with device version 037 the Smart Weather Sensor has an extended supply voltage
range of 4 … 32V DC. Operation with a supply voltage of 24V is recommended. Limitations
apply in case of supply voltages lower than 12V (see below).
8.1.1 Limitations in 12V mode
If the heating is operated on 12V DC, account must be taken of the functional restrictions in
winter operation.
Note: A heating voltage of 24V DC is recommended to guarantee full heating duty.
8.1.2 Limitations in Case of Operation with Supply Voltage Below 12V
When operating a Smart Weather Sensor (device version >= 037) with supply voltages lower
than 12V DC, the fan will be not switched on, independent of the fan operating mode. This
may influence the accuracy of temperature and humidity measurement in case of solar
radiation.
Additionally deviations of the compass measurement values have to be accepted.
When operating the Smart Weather Sensor in Power Save Modes with supply voltages
below 12V the minimal supply voltage depends on the length of the connection cable.
The minimal permitted supply voltage (UBmin)can be approximately evaluated from the
equation:
UBmin = 4V + 0.3V (cable length / m)
The minimal supply voltage for a 10m cable is then UBmin = 6V. The influence of the cable
length on minimal supply voltage can be reduced by using of a cable with larger wire cross
section.
8.2
RS485 Interface
The equipment has an electrically isolated, half-duplex, 2 wire RS485 interface for
configuration, measurement polling and the firmware update.
See page 46 for technical details.
28
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
8.3
Connection to ISOCON-UMB (8160.UISO)
Brown: Positive voltage supply
+24V
White: Supply voltage ground
GND2
Green: RS485
Interface A
Yellow: RS485
Interface B
Figure 7: Connection to
ISOCON-UMB
Warning: The heating voltage (red = positive heating voltage; blue = heating voltage
ground) is not connected to the ISOCON-UMB but wired direct to the power supply unit.
During installation please also refer to the operating manual for the ISOCON-UMB.
8.4
Use of Surge Protection (8379.USP)
When using surge protection (Order No.: 8379.USP), please pay attention to the connection
example in the surge protection operating instructions.
8.5
Connection of External Temperature and Precipitation Sensors
External sensors are to be connected to pins 5 and 6 of the plug connector, i.e. to the gray
and pink wires of the cable delivered with the Smart Weather Sensor.
The temperature sensors as well as the external rain gauge are unipolar, so any connection
sequence can be chosen.
The type of external sensor has to be set using the UMB Config Tool.
For details please refer to Chapter18.
8.6
(WS100-UMB only: ) Connection of Impulse Output for Rain Gauge
Simulation
The digital impulse output is available between pin 7 (gray wire) Uout and pin 1 (white) GND.
In idle state the voltage level at Uout is approximately equal to the supply voltage. Each time
the configured amount of precipitation is reached, Uout is pulsed for about 50ms to GND
level.
Activation of the rain gauge simulation mode and selection of the resolution have to be set
by ConfigTool.NET.
For details please refer to Chapter 10.2.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
29
Operating Manual
Smart Weather Sensor
Commissioning
After the equipment has been installed and connected correctly, the sensor begins
®
autonomously to take measurements. A Windows PC with serial interface, UMB-ConfigTool software and interface cable (SUB-D 9 pole; jack - socket; 1:1) are required for
configuration and test purposes.
Attention must be paid to the following points:
Check for correct equipment operation on site by carrying out a measurement request with
the aid of the UMB-Config-Tool (see page 39).
Configure the local altitude in order to ensure the correct calculation of relative air
pressure (see page 34).
The device must be aligned to the North in order to ensure correct wind measurement
(see page 24), or the automatic compass correction must be activated (see page 34).
In order to get correct compass headings the local declination must be configured (see
page 18and 34).
If several Smart Weather Sensors are operated on a UMB network, a unique device ID
must be assigned to each device (see page 33).
There is no protective cover to remove on the sensor itself.
30
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
10 Configuration and Test
®
Lufft provides Windows PC software (UMB-Config-Tool) for configuration purposes. The
sensor can also be tested and the firmware updated with the aid of this software.
Note: UMB-Config-Tool is not suitable for configuration settings of the WS100-UMB.
ConfigTool.NET shall be used for configuration settings of the WS100-UMB. Please
refer to the ConfigTool.NET manual.
Attempts to modify the settings of the WS100-UMB by UMB-Config-Tool may render the
device inoperative.
The function test of the WS100-UMB (channel selection and measurement polling) can
optionally be done using UMB-Config-Tool.
With regard to contents the following description applies also to WS100-UMB, as far as the
specific instrumentation of this type is concerned.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
31
Operating Manual
Smart Weather Sensor
10.1 Factory Settings
The Smart Weather Sensor is delivered with the following settings:
Class ID:
Device ID:
Baud rate:
RS485 protocol:
Calculation interval:
Local altitude:
7 (cannot be modified)
1 (gives address 7001h = 28673d)
19200
Binary
10 measurements
0m
Note: The device ID must be changed if several Smart Weather Sensors are operated on a
UMB network, as each device requires a unique ID. It makes sense to start from ID 1 and
continue in ascending order.
10.2 Configuration with the UMB-Config-Tool
The operation of the UMB-Config-Tool is described in detail in the operating instructions for
®
the Windows PC software. For this reason only the menus and functions specific to the
Smart Weather Sensor are described here.
10.2.1 Sensor Selection
The Smart Weather Sensor is shown here with sensor selection WSx-UMB (Class ID 7).
Figure 8: Sensor
Selection
Note: You do require the current version of the UMB-Config-Tool to configure the Smart
Weather Sensor.
Note: All other devices which are used in the polling process, e.g. modems, LCOM etc.,
must be disconnected from the UMB network during configuration.
32
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
10.2.2 Configuration
After a configuration has been loaded, all relevant settings and values can be adjusted.
Depending on the device type, only the settings pertinent to the respective available sensors
are relevant.
10.2.3 General Settings
Figure 9: General
Settings
ID:
Device ID (factory setting 1; assign device IDs to additional devices in
ascending order).
Description:
In order to differentiate the devices you can enter a description here, e.g.
the location.
Linespeed:
Transmission speed of the RS485 interface (factory setting 19200; DO NOT
CHANGE for operation with ISOCON-UMB).
Protocol:
Communications protocol of the sensor (UMB-Binary, UMB-ASCII, SDI-12,
Modbus-RTU, Modbus-ASCII, Terminal-Mode, XDR).
Timeout:
In the event of a temporary changeover of the communications protocol, the
system switches back to the configured protocol after this time (in minutes)
Important note: If the baud rate is changed, after saving the configuration on the sensor,
the sensor communicates at the new baud rate. When operating the sensor in a UMB
network with ISOCON-UMB, this baud rate must not be changed; otherwise the sensor is
no longer addressable and can no longer be configured.
10.2.4 Temperature, Humidity and Fan Settings
Figure 10:
Temperature, Humidity
and Fan Settings
Offset:
Absolute offset on the measurement in the unit of the accompanying
channel (for on-site calibration).
Interval:
Time in minutes for the minimum, maximum and average value calculation
interval.
Fan:
to reduce electrical power consumption, the fan can be switched off.
Note: if the fan is switched off, all heaters will also be switched off!
With the fan switched off deviations in temperature and humidity
measurement can occur by solar radiation!
Note: In order to calculate dew point, absolute humidity and mixing ratio, the temperature
and humidity measurement always requires the same interval. For this reason different
intervals cannot be set.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
33
Operating Manual
Smart Weather Sensor
10.2.5 Pressure,
Figure 11: Pressure
Settings
Offset:
Interval:
Altitude:
Absolute offset on the measurement in the unit of the accompanying
channel.
Time in minutes for the minimum, maximum and average value
calculation interval.
Enter the local altitude in meters here for the correct calculation of
relative air pressure (referenced to sea level).
10.2.6 Wind and Compass Settings
Figure 12: Wind
Settings
Offset:
Absolute offset on the measurement in the unit of the accompanying
channel.
Interval:
Time in minutes for the minimum, maximum and average value
calculation interval.
Windspeed min: Approach velocity onto the wind meter with effect from which a
measurement is transmitted, in the unit of the accompanying channel.
Heater mode:
The device can be configured for heating in different operating modes.
Configure as ‘automatic’ in normal operating mode. You can find a
precise description of the operating modes on page 42.
Local declination: Dependent on the location of the installation; the local declination of the
earth magnetic field has to be considered.
Enable Compass for wind-direction correction:
With activated compass correction all wind direction values will be
corrected according to the alignment of the sensor, as evaluated by the
compass.
Note: The offset is not used for the wind meter at present because on-site calibration is not
possible in this case.
34
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
10.2.7 Precipitation Sensor Settings (Radar)
Figure 13: Precipitation
Sensor Settings
(Radar)
Heater mode:
The device can be configured for heating in different operating modes.
Configure as ‘automatic’ in normal operating mode. You can find a precise
description of the operating modes on page 42.
Followup time precipitation type: for this time (in seconds) the detected precipitation type is
shown; to cover all events, this time must be adjusted to the poll rate.
Note: All other parameters, especially those in the ‘Rainfall calibration data’ tab‚ may only be
changed after consultation with the manufacturer, as they have a major influence on the
functioning and accuracy of the sensor.
10.2.8 Precipitation Sensor Settings (Rain Gauge)
The rain gauge module can be operated with resolutions 0.2mm or 0.5mm. The setting of the
resolution is to be done in two steps:
Mechanical setting
Configuration setting
The mechanical setting works by modifying the effective area of the funnel. The sensor is
delivered with a reduction ring, which can be mounted on the funnel to reduce the area.
Funnel with reduction ring
resolution 0.5mm
Funnel without reduction ring
resolution 0.2mm
Then the resolution is set in the sensor configuration using the UMB Config Tool.
Figure 14: Precipitation
Sensor Settings (Rain
Gauge)
Caution: If mechanical setting and configuration setting do not conform, the sensor will
deliver wrong precipitation values!
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
35
Operating Manual
Smart Weather Sensor
10.2.9 Global Radiation Settings
Figure 15: Global
Radiation Settings
Interval:
Time in minutes for minimum, maximum and average value calculation
10.2.10 Lightning Sensor Settings
Figure 16: Lightning
Sensor Settings
Interval:
Time in minutes for minimum, maximum and average value calculation
10.2.11 Energy Management
Figure 17: Energy
Management Settings
By setting the operating and heating mode, the energy consumption of the device can be
adapted to the circumstances of the installation.
The different settings are described in the following chapters:
36
operating modes of Smart Weather Sensor from page 40
operating modes of the heating from page 42
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
10.2.12 Reset Precipitation Quantity
To reset the accumulated absolute precipitation quantity the UMB-Config-Tool offers the
following function:
Options WSx-UMB reset rain
Figure 18: Reset
Precipitation Quantity
Confirm the reset with ‘Yes’
Note: The precipitation quantities are reset in ALL Smart Weather Sensors on the respective
UMB network. The devices reboots after this function has been used.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
37
Operating Manual
Smart Weather Sensor
10.2.13 (WS100-UMB only) Setting of Rain Gauge Simulation
Note: For configuration settings of the WS100-UMB do not use UMB-Config-Tool, but
ConfigTool.NET. For details of operation please refer to the software manual of
ConfigTool.NET.
Note: while the rain gauge simulation is active communication through the serial interface in
UMB or another serial protocol is not possible. To still allow access to the device for
modification of settings etc. UMB protocol will be active during the first 5 sec after power on.
The necessary procedure is described in detail in chapter Fehler! Verweisquelle konnte
nicht gefunden werden..
Rain gauge simulation is selected as a protocol setting.
Abb. 19: Select
operation mode
„Simulated Rain
Gauge“
The resolution of the simulated rain gauge is defined in the field „Sim. RainGauge
Resolution“. Factory setting is 0.01mm, alternatively 1.0mm or 0.1mm may be selected.
Abb. 20: Configure the
resolution of the
simulated rain gauge
38
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
10.3 Function Test with UMB-Config-Tool
The functions of the Smart Weather Sensor can be tested with the UMB-Config-Tool by
polling various channels.
Note: All other devices which are used in the polling process, e.g. modems, LCOM etc.,
must be disconnected from the UMB network during configuration.
10.3.1 Channels for Measurement Polling
You can select the channel for measurement polling by the UMB-Config-Tool by clicking on
the respective channel.
Figure 21 Measurement
Polling Channels
10.3.2 Example of Measurement Polling
Figure 22 Example of
Measurement Polling
Note: The UMB Config Tool is provided for test and configuration purposes only. It is not
suitable for the permanent acquisition of measurement data. We recommend the use of
professional software solutions for this purpose, e.g. Lufft SmartView3.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
39
Operating Manual
Smart Weather Sensor
10.4 Operating Modes of the Smart Weather Sensor
The power consumption of the Smart Weather Sensor can be adjusted to the properties of
the individual installation by setting the operation mode.
The operation of the power save modes however has certain constraints. These have to be
considered when designing the installation.
In normal operation, where all specified properties of the Smart Weather Sensor are fully
available, the power consumption is mostly determined by heating and fan operation.
10.4.1 Power Saving Mode 1
Following measures are active in power saving mode 1:
The ventilation of the temperature / humidity unit is switched off
All heaters are switched off
The radar rain sensor (WS800-UMB, WS700-UMB, WS600-UMB, WS400-UMB, WS100UMB) is not working continuously. The sensor is activated once per minute for one second
(WS100-UMB: 5sec), if precipitation is detected, it remains turned on until the end of the
event, otherwise it is deactivated after this one second again.
Compass measurement is only performed once after power up. The fan, which is
otherwise deactivated, will be switched on shortly for the time of this measurement.
The WS700-UMB / WS800-UMB increases the measuring cycle time for global radiation
from 10 seconds to 1 minute.
Note: This setting has the following restrictions:
With the fan switched off deviations in temperature and humidity measurement can occur
by solar radiation.
Only limited winter operation is possible in this operating mode because any icing might
prevent the correct operation of the rain sensor or wind meter.
The rain detection may be delayed up to 2 minutes. Short events are possibly not
detected. Thus, deviations in the accuracy of the precipitation quantity are possible.
Compared with normal operation the power consumption of a WS600-UMB can be reduced
to 10% even neglecting the heating. (during precipitation events the consumption is slightly
higher, due to the rain sensor then permanently switched on, about 20% compared to normal
operation).
40
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
10.4.2 Power Saving Mode 2
Power saving mode 2 permits another relevant reduction of the power consumption, but
adds on the other hand more severe restrictions.
In this operation mode the device will be almost completely switched off and will wake up
only by the data request for one measurement cycle. During measurement and data
transmission the device will be switched on for about 10 – 15 sec. The total consumption will
be mostly determined by the data request interval.
Note: This operating mode has the following restrictions:
All restrictions of power saving mode 1
Power saving mode 2 is not available for devices with radar rain sensor (WS800-UMB,
WS700-UMB, WS600-UMB, WS400-UMB, WS100-UMB). We recommend devices with
tipping bucket rain gauge for low power applications.
The calculation of average, minimum and maximum as well as precipitation intensity are
not available. Only instantaneous values will be transmitted.
Compass measurement is only performed once after power up. The fan, which is
otherwise deactivated, will be switched on shortly for the time of this measurement.
Communication protocol Modbus is not available
When using the UMB protocol a certain request sequence and timing is required (s. Chap.
19.3.7). The interval length must be at least 15sec to make sure that the measurement
and transmission cycle can be completed. Shorter interval could cause the device to stay
in transmission state without starting a new measurement.
The joint operation with other sensors in an UMB network is possible, but it has to be
considered that each telegram (even when addressed to another device) will cause the
Smart Weather Sensor to wake up for at least several seconds, thus increasing the total
power consumption. The minimum interval length must be hold up under consideration of
the telegrams with other addresses. Mixed operation of devices in power saving mode 2
with devices in normal operation and fast request rates within the same UMB network is
not possible.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
41
Operating Manual
Smart Weather Sensor
10.5 Operating Modes for Equipment Heating
Heating is configured to ‘Automatic’ when the product is delivered. This is the recommended
operating mode for heating the sensor.
You can set the following operating modes:
Heater
Mode
Automatic
Off
Mode 1
Eco-Mode 1
WS100WS600WS200- WS400- WS500- WS501WS601UMB
UMB
UMB
UMB
UMB
UMB *)
UMB
**)
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
*) is also valid for WS502-UMB, WS503-UMB, WS504-UMB, WS510-UMB
**) is also valid for WS700-UMB and WS800-UMB
Note: Model WS30x-UMB and WS401-UMB are not heated.
The rain sensor and wind meter settings must be adjusted in the respective configuration
mask. The examples show the wind meter setting.
10.5.1 Automatic
In this operating mode, the sensor is maintained constantly at the control temperature,
generally in order to prevent the effects of snow and ice.
Figure 23: Operating
Modes for Equipment
Heating
Setpoint Temp.:
The heating controls at this temperature (in °C)
The settings for the other values are not relevant.
10.5.2 Off
In the ‘Off’ operating mode heating is completely disabled. Winter operation is not possible in
this operating mode because any icing might prevent the correct operation of the rain sensor
or wind meter.
The value settings are not relevant.
10.5.3 Mode 1
In ‘Mode 1’ operating mode heating is only enabled when the outside temperature falls below
the HeatingMode1 temperature (in °C). In this mode power consumption can be reduced in
frost-free situations with no great restriction on winter operation.
Setpoint Temp.:
Heating mode1 Temp.:
The heating controls at this temperature (in °C)
Threshold temperature (in °C) with effect from
which air temperature heating is enabled
The ‘Eco Mode1 follow-up time’ setting is not relevant.
42
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
10.5.4 Eco-Mode 1
Eco Mode1 is an advanced energy saving mode.
Heating is only switched on when the following conditions are met:
The outside temperature is below the threshold temperature and precipitation was
detected. Heating then runs at the control temperature for 30 minutes (after the last
precipitation event).
When the outside temperature lies constantly below the threshold temperature and there
was no heating for more than 20h, heating is switched on for 30 minutes as a
precautionary measure in order to thaw any icing.
However, the precautionary 20h-heating only runs if the outside temperature was measured
at below the threshold temperature for the entire period and conditions were constantly
bright for at least 3 hours.
Setpoint Temp.:
Heating mode1 Temp.:
The heating controls at this temperature (in °C)
Threshold temperature (in °C) with effect from
which heating is enabled
Follow-up time (in minutes)
Eco mode1 follow-up time:
Examples:
Outside temperature constantly below 5°C; no precipitation for more than 24h
Outside temperature constantly below 5°C; with precipitation
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
43
Operating Manual
Smart Weather Sensor
11 Firmware Update
To keep the sensor in accordance with the latest state-of-the-art, it is possible to carry out a
firmware update on site with no need to remove the sensor and return it to the manufacturer.
The firmware update is carried out with the aid of the UMB-Config-Tool.
The firmware update of the WS100-UMB is carried out with ConfigTool.NET.
The description of the firmware update can be found in the instructions for the UMB-ConfigTool. Please download the latest firmware and UMB-Config-Tool from our website
®
www.lufft.com and install it on a Windows PC. You can find the instructions here:
Note: When a firmware update takes place, under certain circumstances the absolute
precipitation quantities are reset (channel 600 – 660).
There is one firmware for the entire product family (except WS100-UMB) which supports all
models (WSx_Release_Vxx.mot).
The firmware for WS100-UMB is named WS100_Release_Vxx.bin.
Important Note: please read the included text file in WSx_Release_Vxx.zip; it contains
important information about the update!
12 Maintenance
In principle the equipment is maintenance-free.
However, it is recommended to carry out a functional test on an annual basis. When doing
so, pay attention to the following points:
Visual inspection of the equipment for soiling
Check the sensors by carrying out a measurement request
Check the operation of the fan (not on WS200-UMB)
In addition, an annual calibration check by the manufacturer is recommended for the
humidity sensor (not on WS200-UMB). It is not possible to remove or replace the humidity
sensor. The complete Smart Weather Sensor must be sent to the manufacturer for testing.
Cleaning of the glass dome at regular intervals is suggested for devices with global radiation
measurement. The length of the interval should be adapted to the local degree of pollution.
Devices with precipitation measurement by rain gauge (WS401-UMB, WS601-UMB): The
rain gauge funnel needs to be cleaned at regular intervals (see below). The length of the
interval should be adapted to the local degree of pollution.
44
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
12.1 Maintenance of the Rain Gauge
The function of the rain gauge will be significantly influenced by pollution of the funnel or the
tipping bucket mechanism. Regular check and, if necessary, cleaning is required. The
maintenance interval depends very much on local conditions and also on seasons (leaves,
pollen, etc.) and therefore cannot be exactly defined here (it may be in the range of weeks).
Figure 24: WS601-UMB
with removed funnel
Only clean when obviously polluted
Avoid moving the tipping mechanism (otherwise wrong counts will occur)
Use water, soft cloth and / or a soft brush for cleaning
Unlock funnel by turning it to the left and lift it off
Clean funnel, specially the sieve slots
Check the inside of the rain gauge module for pollution, especially for spider webs
and insects, if necessary, clean it
Check tipping bucket for pollution, if necessary wash carefully with clean water.
Caution: each movement of the bucket generates a counting pulse and thus may
cause faulty precipitation amounts
Check water drain, clean if necessary
Put funnel back in place and lock it by turning it to the right
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
45
Operating Manual
Smart Weather Sensor
13 Technical Data
Power supply:
24VDC +/- 10%
12VDC with restrictions (see page 28)
Device version >= 037:
4 ... 32V DC
Limitations apply in case of supply voltage
less than 12V (see p. 28 f.)
Current consumption – sensor; values for devices prior to version 037 in brackets:
Mode
Supply
WS100-UMB
WS200-UMB
WS300-UMB
WS301-UMB
WS302-UMB
WS303-UMB
WS304-UMB
WS310-UMB
WS400-UMB
WS401-UMB
WS500-UMB
WS501-UMB
WS502-UMB
WS503-UMB
WS504-UMB
WS510-UMB
WS600-UMB
WS700-UMB
WS800-UMB
WS601-UMB
Standard
24VDC
42 mA
16 mA
135 mA
135 mA
12VDC
82 mA
25 mA
70 mA
70 mA
Power Saving Mode 1
24VDC
12VDC
17 mA
33 mA
15 mA
24 mA
7 mA
7 mA
8 mA
8 mA
Power Saving Mode 2
24VDC
12VDC
--1 (4) mA
2 mA
1 (4) mA
2 mA
1 (4) mA
2 mA
160 mA
130 mA
140 mA
145 mA
110 mA
65 mA
85 mA
85 mA
7 mA
6 mA
16 mA
16 mA
7 mA
6 mA
25 mA
25 mA
-1 (4) mA
1 (4) mA
1 (4) mA
-2 mA
2 mA
2 mA
160 mA
130 mA
16 mA
25 mA
--
--
140 mA
85 mA
15 mA
24 mA
1 (4) mA
2 mA
Current consumption and power input - heating:
WS100-UMB
WS200-UMB
WS400-UMB
WS500-UMB, WS501-UMB, WS502-UMB
WS503-UMB, WS504-UMB, WS510-UMB
WS600-UMB, WS700-UMB, WS800-UMB
WS601-UMB
380 mA / 9.1VA at 24VDC
833 mA / 20VA at 24VDC
833 mA / 20VA at 24VDC
833 mA / 20VA at 24VDC
1,7 A / 40VA at 24VDC
833mA / 20VA at 24VDC
Dimensions including mounting bracket:
WS100-UMB
WS200-UMB
WS300-UMB
WS301-UMB
WS302-UMB
WS303-UMB
WS304-UMB
WS310-UMB
WS400-UMB
WS401-UMB
WS500-UMB
WS501-UMB
WS502-UMB
WS503-UMB
WS504-UMB
WS510-UMB
WS600-UMB
WS601-UMB
WS700-UMB
WS800-UMB
Ø 150mm, height 190mm
Ø 150mm, height 194mm
Ø 150mm, height 223mm
Ø 150mm, height 268mm
Ø 150mm, height 253mm
Ø 150mm, height 328mm
Ø 150mm, height 313mm
Ø 150mm, height 311mm
Ø 150mm, height 279mm
Ø 164mm, height 380mm
Ø 150mm, height 287mm
Ø 150mm, height 332mm
Ø 150mm, height 377mm
Ø 150mm, height 392mm
Ø 150mm, height 317mm
Ø 150mm, height 376mm
Ø 150mm, height 343mm
Ø 164mm, height 445mm
Ø 150mm, height 344mm
Ø 150mm, height 344mm
Description of operating modes, see page 35
Factory default, recommended setting
46
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
Weight including mounting bracket, excluding connection cable:
WS100-UMB
WS200-UMB
WS300-UMB
WS400-UMB, WS301-UMB, WS302-UMB,
WS303-UMB, WS304-UMB, WS310-UMB
WS401-UMB
WS500-UMB
WS600-UMB, WS501-UMB, WS502-UMB,
WS503-UMB, WS504-UMB, WS700-UMB
WS510-UMB, WS800-UMB
WS601-UMB
ca. 0.6 kg
ca. 0.8 kg
ca. 1.0 kg
ca. 1.3 kg
ca. 1.5 kg
ca. 1.2 kg
ca. 1.5 kg
ca. 1.7 kg
Fastening:
Stainless steel mast bracket for Ø 60 - 76mm
Protection class:
Protection type:
III (SELV)
IP66
Storage Conditions
Permissible storage temperature:
Permissible relative humidity:
-50°C ... +70°C
0 ... 100% RH
Operating Conditions
Permissible operating temperature:
Permissible relative humidity:
Permissible altitude above sea level:
-50°C ... +60°C
0 ... 100% RH
N/A
RS485 interface, 2 wire, half-duplex
Data bits:
Stop bit:
Parity:
No
(SDI-12 mode: 7)
Housing:
Plastic (PC)
(SDI-12 mode: even, Modbus mode none or
even)
Tri-state:
2 bits after stop bit edge
Adjustable baud rates:
1200, 2400, 4800, 9600, 14400, 19200 , 28800, 57600
(In SDI-12 mode, the interface is changed to meet the requirements of the standard.)
Factory setting; baud rate for operation with ISOCON-UMB and firmware update.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
47
Operating Manual
Smart Weather Sensor
13.1 Measuring Range / Accuracy
13.1.1 Air temperature
Measurement process:
NTC
Measuring range:
-50°C ... +60°C
Resolution:
0.1°C (-20°C...+50°C), otherwise 0.2°C
Sensor accuracy:
+/- 0.2°C (-20°C ... +50°C), otherwise +/-0.5°C (>-30°C)
Sampling rate:
1 minute
Units:
°C; °F
(WS100-UMB: the accuracy of the air temperature service channels is not specified)
13.1.2 Humidity
Measurement process:
Measuring range:
Resolution:
Accuracy:
Sampling rate:
Units:
Capacitive
0 ... 100% RH
0.1% RH
+/- 2% RH
1 minute
% RH; g/m³; g/kg
13.1.3 Dewpoint Temperature
Measurement process:
Measuring range:
Resolution:
Accuracy:
Units:
Passive, calculated from temperature and humidity
-50°C ... +60°C
0.1°C
Computed +/- 0.7°C
°C; °F
13.1.4 Air Pressure
Measurement process:
Measuring range:
Resolution:
Accuracy:
Sampling rate:
Unit:
MEMS sensor - capacitive
300 ... 1200hPa
0.1hPa
+/- 0.5hPa (0 … +40°C)
1 minute
hPa
13.1.5 Wind Speed
Measurement process:
Measuring range:
Resolution:
Accuracy:
Response threshold:
Internal sampling frequency:
Instantaneous value:
Output rate for average and
peak gust values:
Units:
13.1.6 Wind Direction
Measurement process:
Measuring range:
Resolution:
Accuracy:
Response threshold:
Internal sampling frequency:
Instantaneous value:
Output rate for average and
peak gust values:
48
Ultrasonic
0 … 75m/s (WS601-UMB: 0 … 30m/s)
0.1m/s
±0.3 m/s or ±3% (0...35 m/s)
±5% (>35m/s) RMS
0.3 m/s
15Hz
1 sec / 10sec
1min – 10min (peak calculated from 1sec values)
m/s; km/h; mph; kts
Ultrasonic
0 – 359.9°
0.1°
< 3° (> 1m/s) RMSE
0.3 m/s
15Hz
1 sec / 10sec
1min – 10min (peak calculated from 1sec values)
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
13.1.7 Precipitation
13.1.7.1 WS100-UMB / WS400-UMB / WS600-UMB / WS700-UMB /WS800-UMB
Measurement process:
Radar sensor
Measuring range (drop size):
0.3 mm ... 5.0 mm
Liquid precipitation resolution:
0.01 mm
Precipitation types:
Rain, snow
Repeatability:
Typically > 90%
Response threshold:
0.002 mm
Sampling rate:
Event-dependent on reaching response threshold
Precipitation intensity:
0 … 200 mm/h; Sampling rate 1 minute
13.1.7.2 WS401-UMB / WS601-UMB
Measurement process:
Rain Gauge
Liquid precipitation resolution:
0.2 mm / 0.5mm (adjustable by reduction ring)
Precipitation types:
Rain
Accuracy:
2%
Sampling rate:
1 minute
13.1.8 Compass
Measurement process:
Measurement range:
Resolution:
Accuracy:
Sampling rate:
Integrated electronic compass
0 ... 359°
1.0°
+/- 10°
5 minutes
13.1.9 Global Radiation
Measurement Process
Measurement Range
Resolution
Sampling Rate
Thermopile pyranometer
0.0 ... 2000.0 W/m²
< 1W/m²
10 seconds
13.1.9.1 WS301-UMB / WS501-UMB
Response time (95%)
18s
Non-stability(change/year)
<1%
Non-linearity (0 to 1000 W/m²)
<1%
Directional error (at 80° with 1000 W/m²)
<20 W/m²
Temperature dependence of sensitivity
<5% (-10 to +40°C)
Tilt error (at 1000 W/m²)
<1%
Spectral range (50% points)
300 ... 2800nm
13.1.9.2 WS302-UMB / WS502-UMB / WS700-UMB / WS800-UMB
Response time (95%)
<1s
Spectral range (50% points)
300 ... 1100nm
13.1.9.3 WS310-UMB / WS510-UMB
Response time (95%)
5s
Non-stability(change/year)
<0.5%
Non-linearity (0 to 1000 W/m²)
<0.2%
Directional error (at 80° with 1000 W/m²)
<10 W/m²
Temperature dependence of sensitivity
<1% (-10 to +40°C)
Tilt error (at 1000 W/m²)
<0.2%
Spectral range (50% points)
285 ... 2800nm
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
49
Operating Manual
Smart Weather Sensor
13.1.10 External Temperature SensorWT1 / WST1
Measurement process:
NTC
Measuring range:
-40°C ... +80°C
Resolution:
0.25°C
Sensor accuracy:
+/- 1°C (WST1: +/-0.3°C between -10°C ...+10°C)
Sampling rate:
1 minute
Units:
°C; °F
13.1.11 External Rain GaugeWTB100
Measurement process:
Rain Gauge with bounce-free reed contact (normally
closed)
Liquid precipitation resolution:
0.2 mm / 0.5mm (adjustable by reduction ring)
Precipitation types:
Rain
Accuracy:
2%
Sampling rate:
1 minute
In principle, all rain sensors with bounce-free reed contact (normally open or normally
closed) and with a resolution of 0.1 mm, 0.2 mm, 0.5 mm or 1.0 mm can be used.
50
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
13.2 Drawings
Figure 25: WS100-UMB
Figure 26: WS200-UMB
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
51
Operating Manual
Smart Weather Sensor
Figure 27: WS200-UMB
52
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
Figure 28: WS301-UMB
WS302-UMB, WS303-UMB und WS304-UMB are similar.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
53
Operating Manual
Smart Weather Sensor
Figure 29: WS310-UMB
54
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
Figure 30: WS400-UMB
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
55
Operating Manual
Smart Weather Sensor
Figure 31: WS401-UMB
56
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
Figure 32: WS500-UMB
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
57
Operating Manual
Smart Weather Sensor
Figure 33: WS501-UMB
WS502-UMB, WS503-UMB und WS504-UMB are similar.
58
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
Figure 34: WS510-UMB
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
59
Operating Manual
Smart Weather Sensor
Figure 35: WS600-UMB
60
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
Figure 36: WS601-UMB
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
61
Operating Manual
Smart Weather Sensor
Figure 37: WS700UMB, WS800-UMB
62
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
14 EC Certificate of Conformity
Product:
Smart Weather Sensor
Type:
WS100-UMB (Order No.: 8367.U03 / 8367.U04)
WS200-UMB (Order No.: 8371.U01)
WS300-UMB (Order No.: 8372.U01)
WS301-UMB (Order No.: 8374.U01)
WS302-UMB (Order No.: 8374.U10)
WS303-UMB (Order No.: 8374.U11)
WS304-UMB (Order No.: 8374.U12)
WS310-UMB (Order No.: 8374.U13)
WS400-UMB (Order No.: 8369.U01 / 8369.U02)
WS401-UMB (Order No.: 8377.U01)
WS500-UMB (Order No.: 8373.U01)
WS501-UMB (Order No.: 8375.U01)
WS502-UMB (Order No.: 8375.U10)
WS503-UMB (Order No.: 8375.U11)
WS504-UMB (Order No.: 8375.U12)
WS510-UMB (Order No.: 8375.U13)
WS600-UMB (Order No.: 8370.U01 / 8370.U02)
WS601-UMB (Order No.: 8376.U01)
WS700-UMB (Order No.: 8380.U01)
WS800-UMB (Order No.: 8381.U01)
We herewith certify that the above mentioned equipment complies in design and
construction with the Directives of the European Union and specifically the EMC Directive in
accordance with 2004/108/EC, the RoHS Directive 2011/65/EU and, where required,
Directive 2014/53/EU.
The complete Certificate of Conformity is available for download from the Lufft website
www.lufft.com
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
63
Operating Manual
Smart Weather Sensor
14.1 WS100 FCC Compliance Statement (US)
Product:
Smart Weather Sensor
Type:
WS100-UMB (Order No.: 8367.U03 / 8367.U04)
This device contains FCCID: UF9WS100
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Changes and modifications not expressly approved by manufacturer could void the user’s
authority to operate the equipment.
14.2 WS 100 IC Compliance Statement (CA)
Product:
Smart Weather Sensor
Type:
WS100-UMB (Order No.: 8367.U03 / 8367.U04)
This equipment contains equipment certified under ICID: 6650A-WS100
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicable aux appareils
radio exempts de licence. L’exploration est autorisée aux deux conditions suivantes:
(1) l’appareil ne doit pas produire de brouillage, et
(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le
bouillage est susceptible d’en compromettre le fonctionnement.
64
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
15 Fault Description
Error description
Cause - Remedy
Device does not allow polling / does - Check power supply
not respond
- Check interface connection
- Incorrect device ID check ID; devices are
delivered with ID 1.
The device measures precipitation
but it is not raining
Check that the sensor was installed correctly in
accordance with the instructions.
The measured temperature appears Check the operation of the fan on the underside of
too high / measured humidity
the device.
appears too low
Wind direction values are incorrect
Device is not correctly aligned check that the
device is aligned to the North.
Device transmits error value 24h
(36d)
A channel is being polled that is not available on this
device type; e.g. Channel 200 = humidity is being
polled on a WS200-UMB.
Device transmits error value 28h
(40d)
The device is in the initialization phase following
startup the device delivers measurements after
approx. 10 seconds.
Device transmits error value 50h
(80d)
The device is being operated above the limit of the
specified measuring range.
Device transmits error value 51h
(81d)
The device is being operated below the limit of the
specified measuring range.
Device transmits error value 55h
(85d) during wind measurement
The device is unable to execute a valid
measurement due to the ambient conditions.
This may be due to the following reasons:
- The device is being operated well above the limit of
the specified measuring range
- Very strong horizontal rain or snow
- The wind meter sensors are very dirty clean
sensor
- The wind meter sensors are iced over check
heating mode in the configuration and check
heating function / connection
- There are foreign objects within the measuring
section of the wind meter
- One of the wind meter’s sensors is faulty return
device to manufacturer for repair
The quality of the wind
measurement is not always100%
In normal operation the device should always
transmit 90 – 100%. Values up to 50% do not
represent a general problem.
When the error value 55h (85d) is transmitted this
value is 0%.
If the device permanently transmits values below
50% this may mean that there is a fault.
Device transmits an error value not
listed here
This may be due to a number of reasons contact
the manufacturer’s technical support department.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
65
Operating Manual
Smart Weather Sensor
16 Disposal
16.1 Within the EC
The device shall be disposed of in accordance with European Directives 2002/96/EC and
2003/108/EC (waste electrical and electronic equipment).
16.2 Outside the EC
Please comply with the applicable regulations for the proper disposal of waste electrical and
electronic equipment in your respective country.
17 Repair / Corrective Maintenance
Please arrange for any faulty equipment to be checked and, if necessary, repaired by the
manufacturer exclusively. Do not open the equipment and do not under any circumstances
attempt to carry out your own repairs.
In matters of warranty or repair please contact:
G. Lufft Mess- und Regeltechnik GmbH
Gutenbergstraße 20
70736 Fellbach
P.O. Box 4252
70719 Fellbach
Germany
Phone: +49 711 51822-0
Hotline: +49 711 51822-52
Fax: +49 711 51822-41
E-mail: info@lufft.de
or your local distributor.
17.1 Technical Support
Our Hotline is available for technical questions via the following e-mail address:
hotline@lufft.de
You can also consult frequently asked questions at http://www.lufft.com/ (menu header:
SUPPORT / FAQs).
66
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
18 External Sensor
18.1 External Temperature and Precipitation Sensors
18.1.1 Connection of Temperature and Precipitation Sensors
Additional external sensor can cover the requirements of special measurement requirements
or extend the functionality of Smart Weather Sensors.
Currently the accessory list includes external temperature sensors and the precipitation
detection by tipping bucket rain gauge.
One input is available for this extension, so alternatively one temperature sensor or one
precipitation sensor may be used.
The connection uses the standard connector plug of the Smart Weather Sensor, so normally
the external device will be connected at the end of the cable included with the delivery, in the
control cabinet. As this cable is part of the measuring line care shall be taken when
designing the cabling to avoid parasitic coupling etc. The cable should be as short as
possible. In special cases, e.g. when the external sensor is mounted near to the Smart
Weather Sensor while the control cabinet is distant, the installation of an additional
distribution box should be considered.
The external sensor is connected to pins 5 and 6 of the connector plug, i.e. the grey and pink
wires of the standard cable.
All currently available sensors are unipolar, so the connection sequence is not relevant.
The Smart Weather Sensor must be configured for the selected type of external sensor
(temperature or precipitation) to enable the correct evaluation of the measurement data. The
selection of the sensor type is done through the UMB Config Tool.
Figure 38: Setting type
of external sensor
If the data from the channels of the sensor type currently not selected are requested, the
device will respond with “invalid channel”.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
67
Operating Manual
Smart Weather Sensor
18.1.2 External Temperature Sensor
All models of the WS family (except WS100-UMB) can be used with an external temperature
sensor.
For different application various types of NTC sensor are in supply:
WT1
WST1 for mounting in the road surface (road surface temperature)
for temperature acquisition of devices and surfaces
Mounting / installation of the temperature sensors is shown in the sensor manual.
18.1.3 External Rain Gauge
All models of the WS family without integrated precipitation detection can be used with an
external rain gauge. Models WS100-UMB, WS400-UMB, WS600-UMB, WS401-UMB,
WS601-UMB, WS700-UMB, WS800-UMB with R2S sensor resp. integrated tipping bucket
cannot be equipped with an external rain gauge.
The measurement values of the external rain gauge are on the same channels as the data of
the internal precipitation sensors of WS100-UMB, WS400-UMB, WS600-UMB, WS401-UMB,
WS601-UMB, WS700-UMB and WS800-UMB.
The external rain gauge WTB100 uses the same technology as the integrated rain gauge of
models WS401-UMB and WS601-UMB.
The resolution of the rain gauge WTB100 can be modified by the reduction ring delivered
with the sensor from 0.2mm to 0.5mm.
In principle, all rain sensors with bounce-free reed contact (normally open or normally
closed) and with a resolution of 0.1 mm, 0.2 mm, 0.5 mm or 1.0 mm can be used.
Note: To get the correct amount of rain this “mechanical” selection must be also be set in
Smart Weather Sensors configuration.
The setting is done with the UMB Config Tool by the same procedure as with WS401-UMB
and WS601-UMB (s. Chap.10.2.8).
The WS601/401-UMB’s advices for installation (Chap.7.3.4) and maintenance (Chap.12.1)
are as well valid for the external rain gauge.
Example with WS501-UMB and WTB100 without reduction ring:
Figure 39: Example
WS501-UMB and
WTB100
68
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
19 Appendix
19.1 Channel List Summary
The channel assignment applies to online data requests in binary and ASCII protocol.
UMB Channel
act
min
Measuring Range
max
avg
special
Measurement Variable
(float32)
min
max
unit
°C
Temperatures
100
120
140
160
temperature
-50.0
60.0
105
125
145
165
temperature
-58.0
140.0
°F
external temperature
-40.0
80.0
°C
101
106
external temperature
-40.0
176.0
°F
110
130
150
170
dewpoint
-50.0
60.0
°C
115
135
155
175
dewpoint
-58.0
140.0
°F
111
wind chill temperature
-60.0
70.0
°C
116
wind chill temperature
-76.0
158.0
°F
114
wet bulb temperature
-50.0
60.0
°C
119
wet bulb temperature
-58.0
140.0
°F
112
wind heater temp.
-50.0
150.0
°C
113
R2S heater temp.
-50.0
150.0
°C
117
wind heater temp.
-58.0
302.0
°F
118
R2S heater temp.
-58.0
302.0
°F
Humidity
200
220
240
260
relative humidity
0.0
100.0
205
225
245
265
absolute humidity
0.0
1000.0
g/m³
210
230
250
270
mixing ratio
0.0
1000.0
g/kg
specific enthalpy
-100.0
1000.0
kJ/kg
Enthalpy
215
Pressure
300
320
340
360
abs. air pressure
300
1200
hPa
305
325
345
365
rel. air pressure
300
1200
hPa
air density
0.0
3.0
kg/m³
Air Density
310
Wind
vect. avg
400
420
440
460
480
wind speed
75.0
m/s
405
425
445
465
485
wind speed
270.0
km/h
410
430
450
470
490
wind speed
167.8
mph
415
435
455
475
495
wind speed
145.8
kts
401
wind speed fast
75.0
m/s
406
wind speed fast
270.0
km/h
411
wind speed fast
167.8
mph
416
wind speed fast
145.8
kts
403
wind speed standard deviation
75.0
m/s
413
wind speed standard deviation
167.8
mph
500
wind direction
359.9
°
501
520
540
580
wind direction fast
359.9
°
502
wind direction corr.
359,9
°
503
wind direction standard deviation
359.0
°
805
wind value quality
100.0
806
wind value quality (fast)
100.0
compass heading
359
°
Compass
510
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
69
Operating Manual
Smart Weather Sensor
Precipitation Quantity
Range
Unit
600
float32
Precipitation Quantity - Absolute
0 … 100000
liters/m²
620
float32
Precipitation Quantity - Absolute
0 … 100000
mm
640
float32
Precipitation Quantity - Absolute
0 … 3937
inches
660
605
float32
float32
Precipitation Quantity - Absolute
Precipitation Quantity - Differential
0 … 3937008
0 … 100000
mil
liters/m²
625
float32
Precipitation Quantity - Differential
0 … 100000
mm
645
float32
Precipitation Quantity - Differential
0 … 3937
inches
665
float32
Precipitation Quantity - Differential
0 … 3937008
mil
Precipitation Type
0 = No precipitation
40 = unspecified precipitation
60 = Liquid precipitation, e.g. rain
70 = Solid precipitation, e.g. snow
WS100-UMB only:
67 = freezing rain
69 = sleet
90 = hail
Precipitation Type
700
uint7
Precipitation Intensity
Range
unit
800
float32
Precipitation Intensity
0 … 200.0
l/m²/h
820
float32
Precipitation Intensity
0 … 200.0
mm/h
840
float32
Precipitation Intensity
0 … 7.874
in/h
860
float32
Precipitation Intensity
0 … 7874
mil/h
Global Radiation
act
min
max
avg
900
920
940
960
max
avg
special
Measurement Variable (float32)
min
max
unit
Global Radiation
1400
W/m²
Measurement Variable (uint16)
min
max
unit
Lightning event (minute)
255
Lightning event (interval)
7650
10000
Supply Voltage V
0.0
50.0
11000
Rain Drop Volume µl
0.0
500.0
µl
Lightning Detection
act
min
sum
617
677
Service Channels
4100
4120
4140
4160
temperature
-50.0
60.0
°C
4105
4125
4145
4165
temperature
-58.0
140.0
°F
4600
Precipitation: total particles
4294967295
4601
Precipitation: total drops
4294967295
4602
Precipitation: drizzle particles
65535
4603
Precipitation: snow particles
65535
4604
Precipitation: hail particles
65535
4620
Precipitation: Drop class 0
65535
4621
Precipitation: Drop class 1
65535
4622
Precipitation: Drop class 2
65535
4623
Precipitation: Drop class 3
65535
4624
Precipitation: Drop class 4
65535
4625
Precipitation: Drop class 5
65535
4626
Precipitation: Drop class 6
65535
4627
Precipitation: Drop class 7
65535
4628
Precipitation: Drop class 8
65535
4629
Precipitation: Drop class 9
65535
4630
Precipitation: Drop class 10
65535
4631
Precipitation: Drop class 11
65535
Note: Which channels are actually available depends on the WSxxx-UMB type in use.
70
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
19.2 Channel List Summary per TLS2002 FG3
The following channels are available specifically for data requests for further processing in
TLS format. These channels are only available in the UMB-Binary protocol.
DE
Type
UMB
Meaning
Channel
Format Range
Resolution
Coding
48
1048
Result message
Air Temperature
LT
16 bit
-30 ...
+60°C
0.1°C
60.0
0.0
-0.1
-30.0
53
1053
Result message
Precipitation
Intensity NI
16 bit
0 ... 200
mm/h
0.1 mm/h
0.0
200.0
54
1054
Result message
Air Pressure LD
16 bit
800...1200 1 hPa
hPa
800
1200
= 800d = 0320h
= 1200d = 04B0h
55
1055
Result message
Relative Humidity
RLF
8 bit
10% ...
100%
1% RH
10%
100%
= 10d
= 100d
56
1056
Result message
Wind Direction
WR
16 bit
0 ... 359°
1°
0° (N)
= 0d
= 0000h
90° (O)
= 90d = 005Ah
180° (S) = 180d = 00B4h
270° (W) = 270d = 010Eh
FFFFh = not definable
57
1057
Result message
Wind Speed.
(average) WGM
16 bit
0.0 ... 60.0 0.1 m/s
m/s
0.0
60.0
= 0d
= 600d
= 0000h
= 0258h
64
1064
Result message
Wind Speed
(peak) WGS
16 bit
0.0 ... 60.0 0.1 m/s
m/s
0.0
60.0
= 0d
= 600d
= 0000h
= 0258h
66
1066
Result message
16 bit
Dewpoint
Temperature TPT
-30 ...
+60°C
60.0
0.0
-0.1
-30.0
71
1071
Result message
8 bit
Precipitation Type
NS
0.1°C
= 600d
= 0d
= -1d
= -300d
= 0258h
= 0000h
= FFFFh
= FED4h
= 0d
= 0000h
= 2000d = 07D0h
= 0Ah
= 64h
= 600d
= 0d
= -1d
= -300d
= 0258h
= 0000h
= FFFFh
= FED4h
0 = No precipitation
40 = unspecified precipitation
60 = Liquid precipitation, e.g. rain
70 = Solid precipitation, e.g. snow
WS100-UMB only:
67 = freezing rain
69 = sleet
90 = hail
Note: Which channels are actually available depends on the WSxxx-UMB type in use.
The previous channels 1153 and 1253 are no longer supported. Channels 840 and 860 can
be used in their place.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
71
Operating Manual
Smart Weather Sensor
19.3 Communication in Binary Protocol
Only one example of an online data request is described in this operating manual. Please
refer to the current version of the UMB Protocol for all commands and the exact mode of
operation of the protocol (available for download at www.lufft.com).
Note: Communication with the sensor takes place in accordance with the master-slave
principle, i.e. there may only be ONE requesting unit on a network.
19.3.1 Framing
The data frame is constructed as follows:
3-4
5-6
10
SOH STX
11 ... (8 + len)
optional
9 + len
10 + len
11 + len
12 + len
ETX
EOT
SOH
Control character for the start of a frame (01h); 1 byte
Header version number, e.g.: V 1.0 = 10h = 16d; 1 byte
Receiver address; 2 bytes
Sender address; 2 bytes
Number of data bytes between STX and ETX; 1 byte
STX
Control character for the start of payload transmission (02h); 1 byte
Command; 1 byte
Version number of the command; 1 byte
Data bytes; 0 – 210 bytes
ETX
Control character for the end of payload transmission (03h); 1 byte
Check sum, 16 bit CRC; 2 bytes
EOT
Control character for the end of the frame (04h); 1 byte
Control characters: SOH (01h), STX (02h), ETX (03h), EOT (04h).
19.3.2 Addressing with Class and Device ID
Addressing takes place by way of a 16 bit address. This breaks down into a Class ID and a
Device ID.
Address (2 bytes = 16 bit)
Bits 15 – 12 (upper 4 bits)
Class ID (0 to 15)
0 Broadcast
Smart Weather Sensor
(WS200-UMB – WS600-UMB)
Bits 11 – 8
(middle 4 bits)
Reserve
Bits 7 – 0 (lower 8 bits)
Device ID (0 – 255)
Broadcast
1 - 255
Available
15 Master or control devices
ID = 0 is provided as broadcast for classes and devices. Thus it is possible to transmit a
broadcast on a specific class. However this only makes sense if there is only one device of
this class on the bus; or in the case of a command, e.g. reset.
72
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Manual
Smart Weather Sensor
19.3.3 Examples for Creating Addresses
If, for example, you want to address WS400-UMB with the device ID 001, this takes place as
follows:
The class ID for the Smart Weather Sensor is 7d = 7h;
the device ID is e.g. 001d = 001h
Putting the class and device IDs together gives the address 7001h (28673d).
19.3.4 Example of a Binary Protocol Request
If, for example, a Smart Weather Sensor with the device ID 001 is to be polled from a PC for
the current temperature, this takes place as follows:
Sensor:
The class ID for the Smart Weather Sensors 7 = 7h;
The device ID is 001 = 001h
Putting the class and device IDs together gives a target address of 7001h.
PC:
The class ID for the PC (master unit) is 15 = Fh;
the PC ID is e.g. 001d = 01h.
Putting the class and device IDs together gives a sender address of F001h.
The length for the online data request command is 4d = 04h;
The command for the online data request is 23h;
The version number of the command is 1.0 = 10h.
The channel number is in ; as can be seen from the channel list (page 69), the
current temperature in °C in the channel is 100d = 0064h.
The calculated CRC is D961h.
The request to the device:
SOH
STX ETX
EOT
10
11
12
13 14 15
16
01h 10h 01h 70h 01h F0h 04h 02h
23h
10h
64h 00h 03h 61h D9h 04h
The response from the device:
SOH
STX
10
11
12
13
14
01h 10h 01h F0h 01h 70h 0Ah 02h
23h
10h
00h
64h 00h 16h
ETX
EOT
15 16 17 18 19
20 21
22
00h 00h B4h 41h 03h C6h 22h 04h
Interpretation of the response:
= 00h device o.k. (≠ 00h signifies error code; see page 74)
= Data type of the following value; 16h = float (4 bytes, IEEE format)
= 41B40000h as a float value corresponds to 22.5
The temperature is therefore 22.5°C.
The correct data transmission can be checked with the aid of the check sum (22C6h).
Note: Little Endian (Intel, low byte first) applies when transmitting word and float variables of
addresses or the CRC, for example. This means first the LowByte and then the HighByte.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
73
Operating Manual
Smart Weather Sensor
19.3.5 Status and Error Codes in Binary Protocol
If a measurement request delivers the 00h, the sensor is working correctly. You can
find a complete list of additional codes in the description of the UMB protocol.
Extract from list:
Description
00h (0d)
Command successful; no error; all o.k.
10h (16d)
Unknown command; not supported by this device
11h (17d)
Invalid parameter
24h (36d)
Invalid channel
28h (40d)
Device not ready; e.g. initialization / calibration running
50h (80d)
Measurement variable (+offset) is outside the set display range
51h (81d)
52h (82d)
Measurement value (physical) is outside the measuring range (e.g. ADC over range)
53h (83d)
54h (84d)
Error in measurement data or no valid data available
55h ( 85d)
Device / sensor is unable to execute valid measurement due to ambient conditions
19.3.6 CRC Calculation
CRC is calculated according to the following rules:
Norm:
CRC-CCITT
16
12
Polynomial:
1021h = x + x + x + 1 (LSB first mode)
Start value:
FFFFh
You can find further information in the description of a CRC calculation in UMB Protocol.
19.3.7 Data Request in Power Saving Mode 2
When in power saving mode2 the processor of the Smart Weather Sensor will be usually in
sleep state. For the acquisition of measurement data a certain command sequence and a
certain timing is required:
„Wake Up“ bei sending a , any character or any telegram (a telegram will
not be properly detected and get no response, because the UART is just starting)
1000msec pause for the processor start up
Activation of the measurement cycle by (any) valid telegram addressed to this
device
2000msec pause for the execution of the measurement sequence
Request of the measurement results
Example of a Request Sequence:
Command Data Request (0x23), Channel 100
No response
Wait 1 sec
Command Data Request (0x23), Channel 100
Discard data
Wait 2 sec
CommandMultiData Request (0x2F), Ch. 100, 200, 300, 620, 605, 700
Store data
74
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.4 Communication in ASCII Protocol
Note: UMB-ASCII protocol is not recommended for new projects. New features and
sensors will not be implemented for this protocol for devices newer than device
version 223 (WS100-UMB device version 04).
Text-based communication with devices is possible using ASCII protocol.
To do this, in the device configuration, interface settings, the protocol mode must be set to
ASCII (see page 33).
ASCII protocol is network-compatible and serves exclusively for online data requests. The
device will not respond to incomprehensible ASCII commands.
Note: The use of binary protocol is recommended for lengthy transmission routes (e.g.
network, GPRS/UMTS), as ASCII protocol is unable to detect transmission errors (not CRCsecured).
Note: TLS channels are not available in ASCII protocol.
19.4.1 Structure
An ASCII command is introduced by the ‘&’ character and completed by the CR (0Dh) sign.
There is a space character (20h) between the individual blocks in each case; this is
represented by an underscore character ‘_’. Characters that represent an ASCII value are in
ordinary inverted commas.
19.4.2 Summary of ASCII Commands
Command Function
BC
AZ
Online data request
Switches to binary protocol
Triggers software reset
Software reset with delay
Device information
These operating instructions describe the online data request only. You can find the
description of the other commands in the UMB protocol.
19.4.3 Online Data Request (M)
Description: By way of this command, a measurement value is requested from a specific
channel.
Request:
‘&’_ _‘M’_ CR
Response: ‘$’_ _‘M’_ _ CR
Device address (5 decimal places with leading zeros)
Indicates the channel number (5 decimal places with leading zeros)
Measurement value (5 decimal places with leading zeros); a measurement
value standardized to 0 – 65520d. Various error codes are defined from
65521d – 65535d.
Example:
Request:
&_28673_M_00100
By way of this request, channel 100 of the device with address 28673 is interrogated (Smart
Weather Sensor with device ID 001).
Response: $_28673_M_00100_34785
This channel outputs a temperature from –50 to +60°C, which is calculated as follows:
0d
corresponds to -50°C
65520d
corresponds to +60°C
36789d
corresponds to [+60°C – (-50°C)] / 65520 * 34785 +(-50°C) = 8.4°C
Note: TLS channels are not available in ASCII protocol.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
75
Operating Manual
Smart Weather Sensor
19.4.4 Standardization of Measurement Values in ASCII Protocol
The standardization of measurement values from 0d – 65520d corresponds to the measuring
range of the respective measurement variable.
Measurement Variable
Measuring Range
Min
Max
Unit
-50.0
60.0
°C
-58.0
140.0
°F
-40.0
80.0
°C
-40.0
176.0
°F
-60.0
70.0
°C
-76.0
158.0
°F
0.0
100.0
0.0
1000.0
g/m³
g/kg
-100.0
1000.0
kJ/kg
300.0
1200.0
hPa
0.0
3.0
kg/m³
Temperature
Temperature
Dew point
Wet Bulb Temperature
External Temperature
Wind chill temperature
Humidity
Relative humidity
Absolute humidity
Mixing ratio
Specific Enthalpy
Pressure
Relative air pressure
Absolute air pressure
Air Density
air density
Wind
0.0
75.0
m/s
0.0
270.0
km/h
0.0
167.8
mph
0.0
145.8
kts
Wind direction
0.0
359.9
°
wind value quality
0.0
100.0
0.0
6552.0
litres / m²
0.0
6552.0
mm
0.0
257.9
inches
0.0
257952.7
mil
0.0
655.2
litres / m²
0.0
655.2
mm
0.0
25.79
inches
0.0
25795.2
mil
Wind speed
Rain
Quantity
Quantity since last request
Precipitation type
0 = No precipitation
40 = Precipitation
60 = Liquid precipitation, e.g. rain
70 = Solid precipitation, e.g. snow
WS100-UMB only:
67 = freezing rain
69 = sleet
90 = hail
0.0
200.0
l/m²/h
0.0
200.0
mm/h
0.0
7.874
in/h
0.0
7874
mil/h
Global Radiation
until device version .049 / .212
0.0
1400.0
W/m²
Global Radiation
from device version .050 / .213
(software version > v5.6)
0.0
2000.0
W/m²
Precipitation intensity
Global Radiation
Lightning Sensor
76
Lightning events (min)
255
Lightning events (interval)
7650
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.4.5 Error Codes in the ASCII Protocol
Various error codes are defined from 65521d – 65535d in addition to the standardisation for
the transmission of measurement values.
65521d
65523d
65524d
65525d
65526d
65534d
65535d
Description
Invalid Channel
Value Overflow
Value Underflow
Error in measurement data or no valid data available
Device / sensor is unable to execute valid measurement due to ambient conditions
Invalid Calibration
Unknown Error
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
77
Operating Manual
Smart Weather Sensor
19.5 Communication in Terminal Mode
It is possible to communicate with a device in a very simple text-based manner using the
terminal mode.
To do this, in the device configuration, interface settings, the protocol mode must be set to
terminal (see page 33).
Note: In the case of communication in the terminal mode, only one single unit may be
connected to the interface, as this protocol is NOT network-compatible. It is used for very
simple measurement value requests.
Note: The use of binary protocol is recommended for lengthy transmission routes (e.g.
network, GPRS/UMTS), as it is not possible to detect transmission errors in terminal mode
(not CRC-secured).
Note: In the terminal mode, measurement values are not available in all units. Furthermore,
status and error messages are not transmitted.
19.5.1 Structure
A terminal consists of an ASCII character and a numeric character. The command is
completed with the sign. There is no echo on entry.
The individual values in the response are separated by a semi-colon (;). The response is
completed with .
An invalid terminal command is acknowledged with ‘FAILED’. Control commands are
acknowledged with ‘OK’.
The command to which the response relates is given at the beginning of each response.
Note: No response times are specified in the terminal mode.
78
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.5.2 Terminal Commands
The terminal commands transmit the following values or have the following functions:
E0
E1
E2
E3
E4
E5
Temperature in °C
Dew point temperature in °C
Wind chill temperature in °C
Relative humidity in %
Relative air pressure in hPa
Wind speed in m/s
Wind direction in °
Precipitation quantity in mm
Precipitation type
Precipitation intensity in mm/h
Temperature in °F
Dew point temperature in °F
Wind chill temperature in °F
Relative humidity in %
Relative air pressure in hPa
Wind speed in mph
Wind direction in °
Precipitation quantity in inches
Precipitation type
Precipitation intensity in inches/h
Act. wind speed in m/s
Min. wind speed in m/s
Max. wind speed in m/s
Avg. wind speed in m/s
Vct. wind speed in m/s
Act. wind direction in °
Min. wind direction in °
Max. wind direction in °
Vct. wind direction in °
Act. wind speed in mph
Min. wind speed in mph
Max. wind speed in mph
Avg. wind speed in mph
Vct. wind speed in mph
Act. wind direction in °
Min. wind direction in °
Max. wind direction in °
Vectorial wind direction in °
Act. Compass heading in °
Act. Global Radiation in W/m²
Min. Global Radiation in W/m²
Max. Global Radiation in W/m²
Avg. Global Radiation in W/m²
Act. Specific Enthalpy in KJ/Kg
Act. Wet Bulb Temperature in °C
Act. Wet Bulb Temperature in °F
Act. Air Density in kg/m³
reserved
reserved
external temperature (act) °C
external temperature (act) °F
lightning events (min)
lightning events (interval)
Ta
Tp
Tw
Hr
Pa
Sa
Da
Ra
Rt
Ri
Ta
Tp
Tw
Hr
Pa
Sa
Da
Ra
Rt
Ri
Sa
Sn
Sx
Sg
Sv
Da
Dn
Dx
Dv
Sa
Sn
Sx
Sg
Sv
Da
Dn
Dx
Dv
Ca
Ga
Gn
Gx
Gg
Ea
Ba
Ba
Ad
La
Lb
Te
Te
Lm
Li
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
(Channel 100)
(Channel 110)
(Channel 111)
(Channel 200)
(Channel 305)
(Channel 400)
(Channel 500)
(Channel 620)
(Channel 700)
(Channel 820)
(Channel 105)
(Channel 115)
(Channel 116)
(Channel 200)
(Channel 305)
(Channel 410)
(Channel 500)
(Channel 640)
(Channel 700)
(Channel 840)
(Channel 400)
(Channel 420)
(Channel 440)
(Channel 460)
(Channel 480)
(Channel 500)
(Channel 520)
(Channel 540)
(Channel 580)
(Channel 410)
(Channel 430)
(Channel 450)
(Channel 470)
(Channel 490)
(Channel 500)
(Channel 520)
(Channel 540)
(Channel 580)
(Channel 510)
(Channel 900)
(Channel 920)
(Channel 940)
(Channel 960)
(Channel 215)
(Channel 114)
(Channel 119)
(Channel 310)
(Channel 710)
(Channel 711)
(Channel 101)
(Channel 106)
(Channel 617)
(Channel 677)
79
Operating Manual
Smart Weather Sensor
E9*
precipitation total particles
precipitation total drops
precipitation drizzle particles
precipitation snow particles
precipitation hail particles
precipitation drop class 0
precipitation drop class 1
precipitation drop class 2
precipitation drop class 3
precipitation drop class 4
precipitation drop class 5
precipitation drop class 6
precipitation drop class 7
precipitation drop class 8
precipitation drop class 9
precipitation drop class 10
precipitation drop class 11
Mx
I1
Displays the same values as Ex, but without additional information such as the
measurement variable and unit
Serial number; date of manufacture; project number; parts list version;
SPLAN version; hardware version; firmware version; E2 version; device version
Outputs the device description
R0
R1
Executes a device reset
Resets the accumulated rain quantity and executes a device reset
X0
Temporarily switches to UMB binary protocol
I0
Tt
Td
Dr
Sn
Ha
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
(Channel 4600)
(Channel 4601)
(Channel 4602)
(Channel 4603)
(Channel 4604)
(Channel 4620)
(Channel 4621)
(Channel 4622)
(Channel 4623)
(Channel 4624)
(Channel 4625)
(Channel 4626)
(Channel 4627)
(Channel 4628)
(Channel 4629)
(Channel 4630)
(Channel 4631)
*) Command E9/M9 is only supported by WS100-UMB
Examples:
E0
M0
E2
M2
I0
R0
80
E0;Ta+024.9C;Tp+012.2C;Tw+026.8C;Hr+045.0P;Pa+0980.6H;
Sa+005.1M;Da+156.6D;Ra+00042.24M;Rt+060N;Ri+002.6M;
M0;+024.9;+012.2;+026.8;+045.0;+0980.6;
+005.1;+156.6;+00042.24;+060;+002.6;
E2;Sa+005.1M;Sn+001.1M;Sx+007.1M;Sg+005.1M;Sv+005.0M;
Da+156.6D;Dn+166.6D;Dx+176.6D;Dv+156.6D;
M2;+005.1;+001.1;+007.1;+005.1;+005.0;
+156.6;+166.6;+176.6;+156.6;
I0;001;0109;0701;004;005;001;016;011;00002;
R0;OK;
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.6 Communication in SDI-12 Mode
The communication in the SDI-12 mode of the Smart Weather Sensor is conforming to the
standard defined in ‚SDI-12 A Serial-Digital Interface Standard for Microprocessor-Based
Sensors Version 1.3 January 12, 2009‘ . The device may be operated in bus mode together
with other SDI-12 sensors, connected to one SDI master (logger).
19.6.1 Preconditions for SDI-12 Operation
As the interface settings defined in the SDI-12 standard are significantly different from the
UMB default settings the related parameters have to be set properly by the UMB Config Tool
(latest version!).
The protocol mode of the device has to be set to “SDI-12”. This will automatically set the
baud rate to 1200.
Figure 40: Sensor
Configuration SDI-12
Measurement data can be transmitted alternatively in metric or US units. The selection is
done by the UMB Config Tool.
Figure 41: Sensor
Configuration SDI-12
Units
Metric units
US units
Note: Please observe drawings on next page and notes on page 27 when connecting a
SDI12 data logger!
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
81
Operating Manual
Smart Weather Sensor
When operating the device in SDI-12 mode it is basically no more possible to access the
device with the UMB Config Tool, due to the different interface parameter settings. To enable
configuration access nevertheless the interface is operated in standard UMB mode (19200
8N1) for the first 5 seconds(*) after reset / power on. During this time the UMB device ID, if
unequal 1, is set to 200, so access will be possible even if the device ID is unknown. If a
valid UMB telegram is received within this 5 sec, the device will stay in UMB mode for the
configured time out (several minutes) so that the configuration can be modified.
Connect the PC to the Smart Weather Sensor through an RS-485 converter
Start the UMB Config Tool and create a WSxxx-UMB with the address (1 or 200) of
the actual device and activate at least one sensor. Start the measurement (will
report connection error at first)
Reset the device (Power off / on)
When measurement values are received the measurement can be terminated, the
interface is now open for configuration.
(*) Remark: The 5 seconds UMB communication are available from program start. Under
consideration of the operating system start, where no communication is possible, the device
will be ready for SDI12 requests after 7.0 – 7.5 seconds.
This timing only applies in case of cold start after power on or reset. This phase will not
occur after “wake up” in Power Saving Mode 2. In this case the device will respond within the
time defined by the SDI12 standard.
Figure. 42: Connecting
to a logger with
integrated power supply
Figure. 43: Connecting
to a logger and a
separate power supply
up to device version
41
Figure. 44: Connecting
to a logger and a
separate power supply
device version 42 and
newer
82
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.6.2 Command Set
For details of the SDI-12 protocol please refer to the above mentioned standard document.
Following commands are available for devices of the WS family:
Note: The examples in the following sections use italics to print the requests from the logger
(0V!)
Command
Function
?!
Address search (Wildcard request, one device only on bus!)
a!
Request device active?
aI!
Request device identification
aAb!
Address change to b ( 0 … 9, A …Z, a … z)
aM!
Measurement basic minimal data set
aM1!
Measurement temperatures
aM2!
Measurement humidity
aM3!
Measurement air pressure
aM4!
Measurement wind
aM5!
Measurement compass
aM6!
Measurement precipitation
aM7!
Measurement global radiation
aM8!
Measurement external temperature
aMC!
Measurement, basic minimal data set, transmit values with CRC
aMC1! ...
aMC8!
aC!
aC1! ...
aC8!
aCC!
aCC1! ...
aCC8!
Measurement (assignment of values as for aMn! commands),
transmit values with CRC
Concurrent measurement, full basic data set
Concurrent measurement, assignment of values as for aMn!
commands, partly extended data sets
Concurrent measurement, transmit values with CRC
Concurrent measurement, assignment of values as for aMn!
commands, partly extended data sets, transmit values with CRC
aD0!
Data request buffer 0
aD1!
Data request buffer 1
aD2!
Data request buffer 2
aD3!
Data request buffer 3
aD4!
Data request buffer 4
aR0!
Data request from continuous measurement, data set 0
aR1!
Data request from continuous measurement, data set 1
aR2!
Data request from continuous measurement, data set 2
aR3!
Data request from continuous measurement, data set 3
aR4!
Data request from continuous measurement, data set 4
aRC0!
Data request from continuous measurement, data set 0 with CRC
aRC1!
Data request from continuous measurement, data set 1 with CRC
aRC2!
Data request from continuous measurement, data set 2 with CRC
aRC3!
Data request from continuous measurement, data set 3 with CRC
aRC4!
Data request from continuous measurement, data set 4 with CRC
aV!
Command verification: Evaluate sensor status and heating
temperatures, data request with aD0!, aD1!
aXU! Change the unit system for SDI data
aXH+nnnn! Set local altitude of the device for calculation of rel. air pressure
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
83
Operating Manual
Smart Weather Sensor
Command
Function
aXD+nnn.n!
Set local compass deviation
aXL!
Set power saving mode
aXMn!
Set the heating mode of the device
aXA+nn! Integration time for average and min/max evaluation
aXC!
Clear the abs. precipitation amount ( includes a device reset)
aXR!
Device reset
The composition of the minimal and the full basic data set depends on the variant (WS100UMB ... WS800-UMB) of the device in question (see below). The same applies to the
availability of the additional measurement commands (aM1!, aC1! etc.)
Due the applied measurement processes the devices of the WS family will, different from
other sensors described in the SDI-12 document, in normal operation mode always
measure continuously. This causes some special properties while in this mode:
84
The device does not need a “Wakeup” and does not have a sleep mode. So the
reactions to “Break” signals and any related timings are inapplicable. “Break” will be
ignored by WS devices.
Data requested with M- or C- commands are always available immediately. The
device will always respond with a000n resp. a000nn. This means the device will not
send any service request and will ignore measurement abort signals. The logger
should request the data immediately.
M- and C- command only differ in the number of values made available in the buffers
(in both cases the maximum permitted by the standards of 9 resp. 20).
We recommend to use the commands for continuous measurement (R-commands)
to request the data.
When in power saving mode 2 the device will wake up by a „Break“ signal. Other
functions of the „Break“ signal are not implemented.
When in power saving mode 2 the device responds to M or C commands with
a002n resp. a002nn and holds the data available within 2 seconds. It will not send a
service request, signals to abort the measurement are ignored.
For the reduced data set in power saving mode 2 a unified data buffer structure for
all device models has been defined. Depending on the individual model unused
channels will be set to the “invalid” marker 999.9.
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.6.3 Address Configuration
UMB Device-ID and SDI-12 Address are connected, but the different address ranges and the
fact, that UMB ID’s are integer numbers, while SDI-12 addresses are ASCII characters, have
to be considered.
The SDI-12 address is built from the UMB device ID as follows:
UMB Device ID 1 (default) corresponds to SDI-12 Address ‘0’ (SDI-12 default).
Changing the SDI12 address by SDI12 setting command also modifies the UMB device ID
accordingly.
Valid Address Ranges:
UMB (dec)
SDI-12 (ASCII)
to
10
‘0’
to
‘9’
18
to
43
‘A’
to
‘Z’
50
to
75
‘a’
to
‘z’
19.6.4 Data Messages
In the interest of simplified evaluation the assignment of measurement values to data buffers
‘0’ ... ‘9’ has been defined unified for all measurement commands. For this reason the
responses to C-requests have been restricted to 35 characters, not using the 75 characters
permitted for these requests
Currently buffers ‘0’ to ‘4’ are in use.
As with M-requests max. 9 values may be transmitted; the base data set of 9 values has
been assigned to buffers ‘0’ and ‘1’. Buffers ‘2’ to ‘4’ contain further measurement values.
This definition guaranties the compatibility to loggers designed according to older versions of
the SDI-12 standard.
The buffer assignment depends on the device variant (WS100-UMB ... WS800-UMB).
The complete set of measurement values, as defined for the UMB protocol has been made
available also in the SDI-12 environment. They can be accessed using the additional M and
C commands (aM1! ... aM8!, aMC1! ... aMC8!, aC1! ... aC8!, aCC1! ... aCC8!) (see below).
If the measurement value is not available for some reason, e.g. sensor failure, this is
indicated by a value of +999.0. or -999.9 The logger can then evaluate the reason of failure
by a aV! Verification request. The following tables show the measurement values in the
sequence they are arranged in the telegram (see example).
Depending on the configuration of the device the values will be transmitted in metric or US
units.
Note: The configured system of units is not indicated in the data messages. The logger may
request this setting with the I-command and adjust the evaluation of the data messages
accordingly
Example: M Request from a WS600-UMB
0M!
00009
0D0!
0+13.5+85.7+1017.0+2.5+3.7
9 measurement values are available
Air temperature 13.5°C, rel. humidity 85.7%, rel. air pressure 1017hPa
avg. wind speed 2.5m/s, max wind speed 3.7m/s.
0D1!
0+43.7+9.8+60+4.4
Wind direction 43.7° wet bulb temperature 9.8°C,
type of precipitation 60 (rain), precipitation intensity 4.4mm/h
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
85
Operating Manual
Smart Weather Sensor
Example: C Request from a WS600-UMB
0M!
000020
0D0!
0+13.5+85.7+1017+2.5+3.7
20 measurement values are available
air temperature 13.5°C, rel. humidity 85.7%, rel. air pressure 1017hPa
avg. wind speed 2.5m/s, max wind speed 3.7m/s.
0D1!
0+43.7+9.8+60+4.4
wind direction 43.7° wet bulb temperature 9.8°C,
type of precipitation 60 (rain), precipitation intensity 4.4mm/h
0D2!
0+11.2+10.3+1.10
dewpoint 11.2°C, wind chill temperature 10,3°C
diff. precipitation 1.10mm
0D3!
0+3.2+0.0+3.5+100.0
act. wind speed 3,2m/s, min. wind speed 0.0 m/s
vect. avg. wind speed 3.5m/s, quality of wind values 100%
0D4!
0+43.7+41.3+45.7+29.3
act. wind direction 43,7°, min. wind direction 41,3°,
max. wind direction 45,7°, specific enthalpy29,3kJ/kg
86
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.6.4.1 Buffer assignment Basic Data Set WS600-UMB / WS700-UMB / WS800-UMB
Device configured for measurement values in metric units:
Measurement value
UMB
Channel
Min
Max
Unit
Air temperature (act)
100
-50.0
60.0
°C
Rel. Humidity (act)
200
0.0
100.0
Rel. Air Pressure
305
300.0
1200.0
hPa
Wind Speed (avg)
460
0.0
75.0
m/s
Wind Speed (max)
440
0.0
75.0
m/s
Wind Direction (vct)
580
0.0
359.9
°
Wet Bulb Temperature (act)
114
-50.0
60.0
°C
Precipitation Type
700
0, 60, 70
Precipitation Intensity
820
0.0
200.0
mm/h
Dew Point (act)
110
-50.0
60.0
°C
Wind chill Temperature (act)
111
-60.0
70.0
°C
Amount of Precip. difference
625
0.00
100000.00
mm
Buffer ‘0’
Buffer ‘1’
Buffer ‘2’
Buffer ‘3’
Wind Speed (act)
400
0.0
75.0
m/s
Wind Speed (min)
420
0.0
75.0
m/s
Wind Speed (vct)
480
0.0
75.0
m/s
Wind Quality
805
0.0
100.0
Wind Direction (act)
500
0.0
359.9
°
Wind Direction (min)
520
0.0
359.9
°
Wind Direction (max)
540
0.0
359.9
°
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Buffer ‘4’
Example: Request Buffer ‘0’
0D0!
0+13.5+85.7+2.5+3.7
Air Temperature 13.5°C, rel. Humidity 85.7%, average wind speed 2.5m/s, peak wind speed 3.7m/s
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
87
Operating Manual
Smart Weather Sensor
Device configured for measurement values in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Air Temperature (act)
105
-58.0
140.0
°F
Rel. Humidity (act)
200
0.0
100.0
Rel. Air Pressure
305
300.0
1200.0
hPa
Wind Speed (avg)
470
0.0
167.8
mph
Wind Speed (max)
450
0.0
167.8
mph
Wind Direction (vct)
580
0.0
359.9
°
Wet Bulb Temperature (act)
119
-58.0
140.0
°F
Precipitation Type
700
0, 60, 70
Precipitation Intensity
840
0.000
7.874
in/h
Dew Point (act)
115
-58.0
140.0
°F
Wind chill Temperature (act)
116
-76.0
158.0
°F
Amount of Precip. difference
645
0.0000
3937.0000
in
Wind Speed (act)
410
0.0
167.8
mph
Wind Speed (min)
430
0.0
167.8
mph
Wind Speed (vct)
490
0.0
167.8
mph
Wind Quality
805
0.0
100.0
Wind Direction(act)
500
0.0
359.9
°
Wind Direction (min)
520
0.0
359.9
°
Wind Direction (max)
540
0.0
359.9
°
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Buffer ‘0’
Buffer ‘1’
Buffer ‘2’
Buffer ‘3’
Buffer ‘4’
88
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.6.4.2 Buffer Assignment Basic Data Set WS500-UMB
Device configured for measurement values in metric units:
Measurement value
UMB
Channel
Min
Max
Unit
Air temperature (act)
100
-50.0
60.0
°C
Rel. Humidity (act)
200
0.0
100.0
Rel. Air Pressure
305
300.0
1200.0
hPa
Wind Speed (avg)
460
0.0
75.0
m/s
Wind Speed (max)
440
0.0
75.0
m/s
Wind Direction (vct)
580
0.0
359.9
°
Wet Bulb Temperature (act)
114
0.0
359.9
°C
Dew Point (act)
110
-50.0
60.0
°C
Wind chill Temperature (act)
111
-60.0
70.0
°C
Buffer ‘0’
Buffer ‘1’
Buffer ‘2’
Wind Speed (act)
400
0.0
75.0
m/s
Wind Speed (min)
420
0.0
75.0
m/s
Wind Speed (vct)
480
0.0
75.0
m/s
Wind Quality
805
0.0
100.0
Wind Direction (act)
500
0.0
359.9
°
Wind Direction (min)
520
0.0
359.9
°
Wind Direction (max)
540
0.0
359.9
°
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Buffer ‘3’
Example: Request Buffer ‘0’
0D0!
0+13.5+85.7+2.5+3.7
Air Temperature 13.5°C, rel. Humidity 85.7%, average wind speed 2.5m/s, peak wind speed 3.7m/s
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
89
Operating Manual
Smart Weather Sensor
Device configured for measurement values in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Air Temperature (act)
105
-58.0
140.0
°F
Rel. Humidity (act)
200
0.0
100.0
Rel. Air Pressure
305
300.0
1200.0
hPa
Wind Speed (avg)
470
0.0
167.8
mph
Wind Speed (max)
450
0.0
167.8
mph
Wind Direction (vct)
580
0.0
359.9
°
Wet Bulb Temperature (act)
119
-58.0
140.0
°F
Dew Point (act)
115
-58.0
140.0
°F
Wind chill Temperature (act)
116
-76.0
158.0
°F
Wind Speed (act)
410
0.0
167.8
mph
Wind Speed (min)
430
0.0
167.8
mph
Wind Speed (vct)
490
0.0
167.8
mph
Wind Quality
805
0.0
100.0
Wind Direction(act)
500
0.0
359.9
°
Wind Direction (min)
520
0.0
359.9
°
Wind Direction (max)
540
0.0
359.9
°
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Buffer ‘0’
Buffer ‘1’
Buffer ‘2’
Buffer ‘3’
90
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.6.4.3 Buffer Assignment Basic Data Set WS400-UMB
Device configured for measurement in metric units:
Measurement Value
UMB
Channel
Min
Max
Unit
Air Temperature (act)
100
-50.0
60.0
°C
Rel. Humidity (act)
200
0.0
100,0
Dew Point (act)
110
-50.0
60.0
°C
Abs. Air Pressure(act)
300
300.0
1200.0
hPa
Rel. Air Pressure (act)
305
300.0
1200.0
hPa
Precipitation Type
700
0, 60, 70
Precipitation Intensity
820
0.0
200.0
mm/h
mm
Buffer ‘0’
Buffer ‘1’
Amount of Precip. Difference
625
0.00
100000.00
Amount of Precip. Absolute
620
0.0
100000.0
mm
Air Temperature (min)
120
-50.0
60.0
°C
Air Temperature (max)
140
-50.0
60.0
°C
Air Temperature (avg)
160
-50.0
60.0
°C
Rel. Humidity (min)
220
0.0
100.0
Rel. Humidity (max)
240
0.0
100.0
Buffer ‘2’
Buffer ‘3’
Rel. Humidity (avg)
260
0.0
100.0
Rel. Air Pressure(min)
325
300.0
1200.0
hPa
Rel. Rel. Humidity (max)
345
300.0
1200.0
hPa
Rel. Rel. Humidity (avg)
365
300.0
1200.0
hPa
Wet Bulb Temperature (act)
114
-50.0
60.0
°C
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Example: Request Buffer ‘0’
0D0!
0+13.5+85.7+11.2+1017.0+1001.0
Air temperature 13.5°C, rel. humidity 85.7%, dew point 11.2°C, rel. air pressure 1017.0hPa, abs. pressure
1001.0hPa
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
91
Operating Manual
Smart Weather Sensor
Device configured for measurement in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Air Temperature (act)
105
-58.0
140.0
°F
Rel. Humidity (act)
200
0.0
100.0
Dew Point (act)
115
-58.0
14.0
°F
Abs. Air Pressure(act)
300
300.0
1200.0
hPa
Rel. Air Pressure (act)
305
300.0
1200.0
hPa
Precipitation Type
700
0, 60, 70
Precipitation Intensity
840
0.000
7.874
in/h
Amount of Precip. Difference
645
0.0000
3937.0000
in
Amount of Precip. Absolute
640
0.000
3937.000
in
Air Temperature (min)
125
-58.0
140.0
°F
Air Temperature (max)
145
-58.0
140.0
°F
Air Temperature (avg)
165
-58.0
140.0
°F
Rel. Humidity (min)
220
0.0
100.0
Rel. Humidity (max)
240
0.0
100.0
Rel. Humidity (avg)
260
0.0
100.0
Rel. Air Pressure(min)
325
300.0
1200.0
hPa
Rel. Rel. Humidity (max)
345
300.0
1200.0
hPa
Rel. Rel. Humidity (avg)
365
300.0
1200.0
hPa
Wet Bulb Temperature (act)
119
-58.0
140.0
°F
Specific Enthalpy
215
-100.0
1000.0
kJ/kg
Buffer ‘0’
Buffer ‘1’
Buffer ‘2’
Buffer ‘3’
92
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.6.4.4 Buffer Assignment Basic Data Set WS300-UMB
Device configured for measurement in metric units:
Measurement Value
UMB
Channel
Min
Max
Unit
Air Temperature (act)
100
-50.0
60.0
°C
Rel. Humidity (act)
200
0.0
100.0
Dew Point (act)
110
-50.0
60.0
°C
Abs. Air Pressure(act)
300
300.0
1200.0
hPa
Rel. Air Pressure (act)
305
300.0
1200.0
hPa
Air Temperature (min)
120
-50.0
60.0
°C
Air Temperature (max)
140
-50.0
60.0
°C
Air Temperature (avg)
160
-50.0
60.0
°C
Rel. Humidity (avg)
260
0.0
100.0
Rel. Humidity (min)
220
0.0
100,0
Rel. Humidity (max)
240
0.0
100,0
Rel. Air Pressure (min)
325
300.0
1200.0
hPa
Rel. Air Pressure (max)
345
300.0
1200.0
hPa
Rel. Air Pressure (avg)
365
300.0
1200.0
hPa
Buffer ‘0’
Buffer ‘1’
Buffer ‘2’
Buffer ‘3’
Abs. Humidity (min)
225
0.0
1000.0
g/m³
Abs. Humidity (max)
245
0.0
1000.0
g/m³
Abs. Humidity (avg)
265
0.0
1000.0
g/m³
Wet Bulb Temperature (act)
114
-50.0
60.0
°C
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Buffer ‘4’
Example: Request buffer ‘0’
0D0!
0+13.5+85.7+11.2+1017.0+1001.0
Air temperature 13.5°C, rel. humidity 85.7%, dew point 11.2°C, rel. air pressure 1017.0hPa, abs. pressure
1001.0hPa
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
93
Operating Manual
Smart Weather Sensor
Device configured for measurement in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Air Temperature (act)
105
-58.0
140.0
°F
Rel. Humidity (act)
200
0.0
100.0
Dew Point (act)
115
-58.0
140.0
°F
Abs. Air Pressure(act)
300
300.0
1200.0
hPa
Rel. Air Pressure (act)
305
300.0
1200.0
hPa
Air Temperature (min)
125
-58.0
140.0
°F
Air Temperature (max)
145
-58.0
140.0
°F
Air Temperature (avg)
165
-58.0
140.0
°F
Rel. Humidity (avg)
260
0.0
100.0
Rel. Humidity (min)
220
0.0
100,0
Rel. Humidity (max)
240
0.0
100,0
Rel. Air Pressure (min)
325
300.0
1200.0
hPa
Rel. Air Pressure (max)
345
300.0
1200.0
hPa
Rel. Air Pressure (avg)
365
300.0
1200.0
hPa
Abs. Humidity (min)
225
0.0
1000.0
g/m³
Abs. Humidity (max)
245
0.0
1000.0
g/m³
Abs. Humidity (avg)
265
0.0
1000.0
g/m³
Wet Bulb Temperature (act)
119
-58.0
140.0
°F
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Buffer ‘0’
Buffer ‘1’
Buffer ‘2’
Buffer ‘3’
Buffer ‘4’
94
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.6.4.5 Buffer Assignment Basic Data Set WS200-UMB
Device configured for measurement values in metric units:
Measurement Value
UMB
Channel
Min
Max
Unit
Wind Speed (avg)
460
0.0
75.0
m/s
Wind Speed (max)
440
0.0
75.0
m/s
Wind Direction (vct)
580
0.0
359.9
°
Wind Direction (act)
500
0.0
359.9
°
Compass Heading(act)
510
0.0
359.0
°
Wind Speed (act)
400
0.0
75.0
m/s
Wind Speed (min)
420
0.0
75.0
m/s
Wind Speed (vct)
480
0.0
75.0
m/s
Wind Quality
805
0.0
100.0
Wind Direction (min)
520
0.0
359.9
°
Wind Direction (max)
540
0.0
359.9
°
Wind Direction corr. (act)
502
0.0
359.9
°
Buffer ‘0’
Buffer ‘1’
Buffer ‘2’
Example: Request Buffer ‘0’
0D0!
0+2.5+3.7+45.5+37.8+10.3
Avg. wind speed 2.5m/s, peak wind speed 3.7m/s, avg wind direction (vect.) 45.5°, wind direction (act.) 37.8°,
compass heading 10.3°
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
95
Operating Manual
Smart Weather Sensor
Device configured for measurement values in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Wind Speed (avg)
470
0.0
167.8
mph
Wind Speed (max)
450
0.0
167.8
mph
Wind Direction (vct)
580
0.0
359.9
°
Wind Direction (act)
500
0.0
359.9
°
Compass Heading(act)
510
0.0
359.0
°
Wind Speed (act)
410
0.0
167.8
mph
Wind Speed (min)
430
0.0
167.8
mph
Wind Speed (vct)
490
0.0
167.8
mph
Wind Quality
805
0.0
100.0
Wind Direction (min)
520
0.0
359.9
°
Wind Direction (max)
540
0.0
359.9
°
Wind Direction corr. (act)
502
0.0
359.9
°
Buffer ‘0’
Buffer ‘1’
Buffer ‘2’
96
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.6.4.6 Buffer Assignment Basic Data Set WS100-UMB
Device configured for measurement values in metric units
Measurement Value
UMB
Channel
Min
Max
Unit
Amount of Precip. absolute
620
0,0
100000,0
mm
Amount of Precip. difference
625
0,00
100000,00
mm
Precipitation Intensity
820
0,0
200,0
mm/h
Precipitation Type
700
0, 60, 70 (67, 69, 90)*
Buffer ‘0’
)* additional precipitation types: WS100-UMB only
Example: Request Buffer ‘0’
0D0!
0+23.5+0.2+3.2+60
Precipitation abs. 23,5mm, precipitation difference 0,2mm, precipitation intensity 3,2mm/h, precipitation type 60
(rain)
Device configured for measurement values in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Amount of Precip. absolute
640
0,000
3937,000
in
Amount of Precip. difference
645
0,0000
3937,0000
in
Precipitation Intensity
840
0,000
7,874
in/h
Precipitation Type
700
0, 60, 70 (67, 69, 90)*
Buffer ‘0’
)* additional precipitation types: WS100-UMB only
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
97
Operating Manual
Smart Weather Sensor
19.6.4.7 Buffer Assignment Basic Data Set WS501-UMB, WS502-UMB, WS503-UMB,
WS504-UMB, WS510-UMB
Device configured for measurement values in metric units:
Measurement value
UMB
Channel
Min
Max
Unit
Air temperature (act)
100
-50.0
60.0
°C
Rel. Humidity (act)
200
0.0
100.0
Rel. Air Pressure
305
300.0
1200.0
hPa
Wind Speed (avg)
460
0.0
75.0
m/s
Wind Speed (max)
440
0.0
75.0
m/s
Wind Direction (vct)
580
0.0
359.9
°
Global Radiation (act)
900
0.0
2000.0 *)
W/m²
Dew Point (act)
110
-50.0
60.0
°C
Wind Chill Temperature (act)
111
-60.0
70.0
°C
Buffer ‘0’
Buffer ‘1’
Buffer ‘2’
Wind Speed (act)
400
0.0
75.0
m/s
Wind Speed (min)
420
0.0
75.0
m/s
Wind Speed (vct)
480
0.0
75.0
m/s
Wind Quality
805
0.0
100.0
Wind Direction (act)
500
0.0
359.9
°
Wet Bulb Temperature (act)
114
-50.0
60.0
°C
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Global Radiation (min)
920
0.0
2000.0 *)
W/m²
Global Radiation (max)
940
0.0
2000.0 *)
W/m²
Global Radiation (avg)
960
0.0
2000.0 *)
W/m²
Buffer ‘3’
Buffer ‘4’
*) Until device version .49 / .212 / Firmware v5.6: 1400.0 W/m
Example: Request Buffer ‘0’
0D0!
0+13.5+85.7+2.5+3.7
Air Temperature 13.5°C, rel. Humidity 85.7%, average wind speed 2.5m/s, peak wind speed 3.7m/s
98
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
Device configured for measurement values in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Air Temperature (act)
105
-58.0
140.0
°F
Rel. Humidity (act)
200
0.0
100.0
Rel. Air Pressure
305
300.0
1200.0
hPa
Wind Speed (avg)
470
0.0
167.8
mph
Wind Speed (max)
450
0.0
167.8
mph
Wind Direction (vct)
580
0.0
359.9
°
Global Radiation (act)
900
0.0
2000.0 *)
W/m²
Dew Point (act)
115
-58.0
140.0
°F
Windchill Temperature (act)
116
-76.0
158.0
°F
Wind Speed (act)
410
0.0
167.8
mph
Wind Speed (min)
430
0.0
167.8
mph
Wind Speed (vct)
490
0.0
167.8
mph
Wind Quality
805
0.0
100.0
Wind Direction(act)
500
0.0
359.9
°
Wet Bulb Temperature (act)
119
-58.0
140.0
°F
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Buffer ‘0’
Buffer ‘1’
Buffer ‘2’
Buffer ‘3’
Buffer ‘4’
Global Radiation (min)
920
0.0
2000.0 *)
W/m²
Global Radiation (max)
940
0.0
2000.0 *)
W/m²
Global Radiation (avg)
960
0.0
2000.0 *)
W/m²
*) Until device version .49 / .212 / Firmware v5.6: 1400.0 W/m
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
99
Operating Manual
Smart Weather Sensor
19.6.4.8 Buffer Assignment Basic Data Set WS301-UMB, WS302-UMB, WS303-UMB,
WS304-UMB, WS310-UMB
Device configured for measurement in metric units:
Measurement Value
UMB
Channel
Min
Max
Unit
Air Temperature (act)
100
-50.0
60.0
°C
Rel. Humidity (act)
200
0.0
100.0
Dew Point (act)
110
-50.0
60.0
°C
Global Radiation(act)
900
0.0
2000.0 *)
W/m²
Rel. Air Pressure (act)
305
300.0
1200.0
hPa
Air Temperature (min)
120
-50.0
60.0
°C
Air Temperature (max)
140
-50.0
60.0
°C
Air Temperature (avg)
160
-50.0
60.0
°C
Rel. Humidity (avg)
260
0.0
100.0
Rel. Humidity (min)
220
0.0
100,0
Rel. Humidity (max)
240
0.0
100,0
Rel. Air Pressure (min)
325
300.0
1200.0
hPa
Rel. Air Pressure (max)
345
300.0
1200.0
hPa
Rel. Air Pressure (avg)
365
300.0
1200.0
hPa
Buffer ‘0’
Buffer ‘1’
Buffer ‘2’
Buffer ‘3’
Abs. Humidity (act)
205
0.0
1000.0
g/m³
Wet Bulb Temperature (act)
114
-50.0
60.0
°C
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Buffer ‘4’
Global Radiation (min)
920
0.0
2000.0 *)
W/m²
Global Radiation (max)
940
0.0
2000.0 *)
W/m²
Global Radiation (avg)
960
0.0
2000.0 *)
W/m²
*) Until device version .49 / .212 / Firmware v5.6: 1400.0 W/m
Example: Request buffer ‘0’
0D0!
0+13.5+85.7+11.2+1017.0+780.0
Air temperature 13.5°C, rel. humidity 85.7%, dew point 11.2°C, rel. air pressure 1017.0hPa, global radiation
780.0W/m²
100
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
Device configured for measurement in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Air Temperature (act)
105
-58.0
140.0
°F
Rel. Humidity (act)
200
0.0
100.0
Dew Point (act)
115
-58.0
140.0
°F
Global Radiation(act)
900
0.0
2000.0 *)
W/m²
Rel. Air Pressure (act)
305
300.0
1200.0
hPa
Air Temperature (min)
125
-58.0
140.0
°F
Air Temperature (max)
145
-58.0
140.0
°F
Air Temperature (avg)
165
-58.0
140.0
°F
Rel. Humidity (avg)
260
0.0
100.0
Rel. Humidity (min)
220
0.0
100,0
Rel. Humidity (max)
240
0.0
100,0
Rel. Air Pressure (min)
325
300.0
1200.0
hPa
Rel. Air Pressure (max)
345
300.0
1200.0
hPa
Rel. Air Pressure (avg)
365
300.0
1200.0
hPa
Abs. Humidity (act)
205
0.0
1000.0
g/m³
Wet Bulb Temperature (act)
119
-58.0
140.0
°F
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Buffer ‘0’
Buffer ‘1’
Buffer ‘2’
Buffer ‘3’
Buffer ‘4’
Global Radiation (min)
920
0.0
2000.0 *)
W/m²
Global Radiation (max)
940
0.0
2000.0 *)
W/m²
Global Radiation (avg)
960
0.0
2000.0 *)
W/m²
*) Until device version .49 / .212 / Firmware v5.6: 1400.0 W/m
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
101
Operating Manual
Smart Weather Sensor
19.6.4.9 Buffer assignment Basic Data Set WS601-UMB
Device configured for measurement values in metric units:
Measurement value
UMB
Channel
Min
Max
Unit
Air temperature (act)
100
-50.0
60.0
°C
Rel. Humidity (act)
200
0.0
100.0
Rel. Air Pressure
305
300.0
1200.0
hPa
Wind Speed (avg)
460
0.0
75.0
m/s
Wind Speed (max)
440
0.0
75.0
m/s
580
0.0
359.9
°
Precipitation Type
700
0, 40
Precipitation Intensity
820
0.0
200.0
mm/h
Dew Point (act)
110
-50.0
60.0
°C
Wind chill Temperature (act)
111
-60.0
70.0
°C
Amount of Precip. difference
625
0.00
100000.00
mm
Buffer ‘0’
Buffer ‘1’
Wind Direction (vct)
reserved
Buffer ‘2’
Buffer ‘3’
Wind Speed (act)
400
0.0
75.0
m/s
Wind Speed (min)
420
0.0
75.0
m/s
Wind Speed (vct)
480
0.0
75.0
m/s
Wet Bulb Temperature (act)
114
-50.0
60.0
°C
Wind Direction (act)
500
0.0
359.9
°
Wind Direction (min)
520
0.0
359.9
°
Wind Direction (max)
540
0.0
359.9
°
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Buffer ‘4’
Example: Request Buffer ‘0’
0D0!
0+13.5+85.7+2.5+3.7
Air Temperature 13.5°C, rel. Humidity 85.7%, average wind speed 2.5m/s, peak wind speed 3.7m/s
102
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
Device configured for measurement values in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Air Temperature (act)
105
-58.0
140.0
°F
Rel. Humidity (act)
200
0.0
100.0
Rel. Air Pressure
305
300.0
1200.0
hPa
Wind Speed (avg)
470
0.0
167.8
mph
Wind Speed (max)
450
0.0
167.8
mph
580
0.0
359.9
°
Precipitation Type
700
0, 40
Precipitation Intensity
840
0.000
7.874
in/h
Dew Point (act)
115
-58.0
140.0
°F
Wind chill Temperature (act)
116
-76.0
158.0
°F
Amount of Precip. difference
645
0.0000
3937.0000
in
Wind Speed (act)
410
0.0
167.8
mph
Wind Speed (min)
430
0.0
167.8
mph
Wind Speed (vct)
490
0.0
167.8
mph
Wet Bulb Temperature (act)
119
-58.0
140.0
°F
Wind Direction(act)
500
0.0
359.9
°
Wind Direction (min)
520
0.0
359.9
°
Wind Direction (max)
540
0.0
359.9
°
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Buffer ‘0’
Buffer ‘1’
Wind Direction (vct)
reserved
Buffer ‘2’
Buffer ‘3’
Buffer ‘4’
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
103
Operating Manual
Smart Weather Sensor
19.6.4.10 Buffer Assignment Basic Data Set WS401-UMB
Device configured for measurement in metric units:
Measurement Value
UMB
Channel
Min
Max
Unit
Air Temperature (act)
100
-50.0
60.0
°C
Rel. Humidity (act)
200
0.0
100,0
Dew Point (act)
110
-50.0
60.0
°C
305
300.0
1200.0
hPa
Precipitation Type
700
0, 40
Precipitation Intensity
820
0.0
200.0
mm/h
mm
Buffer ‘0’
reserved
Rel. Air Pressure (act)
Buffer ‘1’
Amount of Precip. Difference
625
0.00
100000.00
Amount of Precip. Absolute
620
0.0
100000.0
mm
Air Temperature (min)
120
-50.0
60.0
°C
Air Temperature (max)
140
-50.0
60.0
°C
Air Temperature (avg)
160
-50.0
60.0
°C
Rel. Humidity (min)
220
0.0
100.0
Rel. Humidity (max)
240
0.0
100.0
Buffer ‘2’
Buffer ‘3’
Rel. Humidity (avg)
260
0.0
100.0
Rel. Air Pressure(min)
325
300.0
1200.0
hPa
Rel. Rel. Humidity (max)
345
300.0
1200.0
hPa
Rel. Rel. Humidity (avg)
365
300.0
1200.0
hPa
Wet Bulb Temperature (act)
114
-50.0
60.0
°C
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Example: Request Buffer ‘0’
0D0!
0+13.5+85.7+11.2+1017.0+1001.0
Air temperature 13.5°C, rel. humidity 85.7%, dew point 11.2°C, rel. air pressure 1017.0hPa, abs. pressure
1001.0hPa
104
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
Device configured for measurement in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Air Temperature (act)
105
-58.0
140.0
°F
Rel. Humidity (act)
200
0.0
100.0
Dew Point (act)
115
-58.0
14.0
°F
305
300.0
1200.0
hPa
Precipitation Type
700
0, 40
Precipitation Intensity
840
0.000
7.874
in/h
Amount of Precip. Difference
645
0.0000
3937.0000
in
Amount of Precip. Absolute
640
0.000
3937.000
in
Air Temperature (min)
125
-58.0
140.0
°F
Air Temperature (max)
145
-58.0
140.0
°F
Air Temperature (avg)
165
-58.0
140.0
°F
Rel. Humidity (min)
220
0.0
100.0
Rel. Humidity (max)
240
0.0
100.0
Rel. Humidity (avg)
260
0.0
100.0
Rel. Air Pressure(min)
325
300.0
1200.0
hPa
Rel. Rel. Humidity (max)
345
300.0
1200.0
hPa
Rel. Rel. Humidity (avg)
365
300.0
1200.0
hPa
Wet Bulb Temperature (act)
119
-58.0
140.0
°F
Specific Enthalpy
215
-100.0
1000.0
kJ/kg
Buffer ‘0’
reserved
Rel. Air Pressure (act)
Buffer ‘1’
Buffer ‘2’
Buffer ‘3’
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
105
Operating Manual
Smart Weather Sensor
19.6.4.11 Buffer Assignment Basic Data Set Power Saving Mode 2 (all Models)
Device configured for measurement in metric units:
Measurement Value
UMB
Channel
Min
Max
Unit
Air Temperature (act)
100
-50.0
60.0
°C
Rel. Humidity (act)
200
0.0
100.0
Amount of Precip. Difference
625
0.00
100000.00
mm
Rel. Air Pressure(act)
305
300.0
1200.0
hPa
Wind Speed (act)
400
0.0
75.0
m/s
Wind Direction(act)
500
0.0
359.9
°
Global Radiation
900
0.0
2000.0 *)
W/m
101
-20.0
80.0
°C
Amount of Precip. Absolute
620
0.0
100000.0
mm
Dew point (act)
110
-50.0
60.0
°C
Abs. Humidity (act)
205
0.0
1000.0
g/m³
Mixing Ratio(act)
210
0.0
1000.0
g/kg
Abs. Air Pressure(act)
300
300.0
1200.0
hPa
Buffer ‘0’
Buffer ‘1’
reserved
External Temperature
Buffer ‘2’
Buffer ‘3’
Wet Bulb Temperature (act)
114
-50.0
60.0
°C
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Air Density
310
0.000
3.000
kg/m3
Compass (act)
510
0.0
359.0
°
*) Until device version .49 / .212 / Firmware v5.6: 1400.0 W/m
Example: Request Buffer ‘0’
0D0!
0+13.5+85.7+0.2+1017.0+1.8
Air temperature 13.5°C, rel. humidity 85.7%, precipitation 0.2°C, rel. air pressure 1017.0hPa, wind speed1.8m/s
106
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
Device configured for measurement in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Air Temperature (act)
105
-58.0
140.0
°F
Rel. Humidity (act)
200
0.0
100.0
Amount of Precip. Difference
645
0.0000
3937.0000
in
Rel. Air Pressure(act)
305
300.0
12000
hPa
Wind Speed (act)
410
0.0
167.8
mph
Wind Direction(act)
500
0.0
359.9
°
Global Radiation
900
0.0
2000.0 *)
W/m
106
-4.0
176.0
°F
Amount of Precip. Absolute
640
0.000
3937.000
in
Dew point (act)
115
-58.0
140.0
°F
Abs. Humidity (act)
205
0.0
1000.0
g/m³
Mixing Ratio(act)
210
0.0
1000.0
g/kg
Abs. Air Pressure(act)
300
300.0
1200.0
hPa
Wet Bulb Temperature (act)
119
-58.0
140.0
°F
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Air Density
310
0.000
3.000
kg/m3
Compass (act)
510
0.0
359.0
°
Buffer ‘0’
Buffer ‘1’
reserved
External Temperature
Buffer ‘2’
Buffer ‘3’
*) Until device version .49 / .212 / Firmware v5.6: 1400.0 W/m
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
107
Operating Manual
Smart Weather Sensor
19.6.5 Additional Measurement Commands
With the additional measurement commands
aM1! … aM8!
aMC1! … aMC8!
(M-Command, data transmission with CRC)
aC1! … aC8!
aCC1! … aCC8!
(C- Command, data transmission with CRC)
The complete data sets of the Smart Weather Sensor, as defined for the UMB protocol are
available in a SDI-12 environment as well.
The measurement values are ordered according to sensor types.
Equally to the base data sets max. 9 values can be requested with an additional M
command, while an additional C request allows for up to 20 values.
The buffer assignment as documented in the following paragraphs has consequently been
structured in a way that with each M command the buffers D0 and D1 are used. If the
respective sensor type has more values available the buffers D2 up to D4 will be occupied if
required.
M1 / C1
Temperature
M: 9 Values
C: 9 Values
M2 / C2
Humidity
M: 9 Values
C: 13 Values
M3 / C3
Air Pressure
M: 9 Values
C: 9 Values
M4 / C4
Wind
M: 9 Values
C: 14 Values
M5 / C5
Compass
M: 1 Values
C: 1 Values
M6 / C6
WS401/601:
Others:
Precipitation
Precipitation
M: 9 Values
M: 4 Values
C: 9 Values
C: 4 Values
M7 / C7
WS800-UMB: Global Radiation,
Lightning Sensor
M: 9 Values
WS100-UMB: Drop Diameter Distrib. M: --Others:
Global Radiation
M: 4 Values
C: 10 Values
C: 17 Values
C: 4 Values
M8 / C8
C: 1 Value
Ext. Temperature
M: 1 Value
If the sensor type requested with the measurement command is not available with the actual
variant of the Smart Weather Sensor (WS100-UMB ... WS800-UMB) the device will respond
with
a0000 resp.
a00000
108
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.6.5.1 Buffer Assignment Additional Measurement Commands M1 / C1:
Temperature
Device configured for measurement values in metric units:
Measurement Value
UMB
Channel
Min
Max
Unit
Air Temperature (act)
100
-50.0
60.0
°C
Air Temperature (min)
120
-50.0
60.0
°C
Air Temperature (max)
140
-50.0
60.0
°C
Air Temperature (avg)
160
-50.0
60.0
°C
Dew Point (act)
110
-50.0
60.0
°C
Dew Point (min)
130
-50.0
60.0
°C
Dew Point (max)
150
-50.0
60.0
°C
Dew Point (avg)
170
-50.0
60.0
°C
Wet Bulb Temperature (act)
114
-50.0
60.0
°C
Buffer ‘0’
Buffer ‘1’
Example: Request with M command
0M1!
00009
0D0!
0+12.5+10.7+13.5+11.8+5.3
0D1!
0+4.2+5.9+5.6+9.8
Device configured for measurement values in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Air Temperature (act)
105
-58.0
140.0
°F
Air Temperature (min)
125
-58.0
140.0
°F
Air Temperature (max)
145
-58.0
140.0
°F
Air Temperature (avg)
165
-58.0
140.0
°F
Dew Point (act)
115
-58.0
140.0
°F
Dew Point (min)
135
-58.0
140.0
°F
Dew Point (max)
155
-58.0
140.0
°F
Dew Point (avg)
175
-58.0
140.0
°F
Wet Bulb Temperature (act)
119
-58.0
140.0
°F
Buffer ‘0’
Buffer ‘1’
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
109
Operating Manual
Smart Weather Sensor
19.6.5.2 Buffer Assignment Additional Measurement Commands M2 / C2: Humidity
Device configured for measurement values in metric or US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Rel. Humidity (act)
200
0.0
100.0
Rel. Humidity (min)
220
0.0
100.0
Rel. Humidity (max)
240
0.0
100.0
Rel. Humidity (avg)
260
0.0
100.0
Abs. Humidity (act)
205
0.0
1000.0
g/m³
Abs. Humidity (min)
225
0.0
1000.0
g/m³
Abs. Humidity (max)
245
0.0
1000.0
g/m³
Abs. Humidity (avg)
265
0.0
1000.0
g/m³
Specific Enthalpy (act)
215
-100.0
1000.0
kJ/kg
Mixing Ratio(act)
210
0.0
1000.0
g/kg
Mixing Ratio (min)
230
0.0
1000.0
g/kg
Mixing Ratio (max)
250
0.0
1000.0
g/kg
Mixing Ratio (avg)
270
0.0
1000.0
g/kg
Buffer ‘0’
Buffer ‘1’
Buffer ‘2’
Example: Request with M command
0M2!
00009
0D0!
0+48.5+48.2+48.8+48.5
0D1!
0+5.7+5.5+5.9+5.7+29.3
Example: Request with C command
0C2!
000013
0D0!
0+48.5+48.2+48.8+48.5
0D1!
0+5.7+5.5+5.9+5.7+29.3
0D2!
0+4.6+4.4+5.0+4.6
110
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.6.5.3 Buffer Assignment Additional Measurement Commands M3 / C3: Air
Pressure
Device configured for measurement values in metric or US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Abs. Air Pressure(act)
300
300.0
1200.0
hPa
Abs. Air Pressure (min)
320
300.0
1200.0
hPa
Abs. Air Pressure (max)
340
300.0
1200.0
hPa
Abs. Air Pressure (avg)
360
300.0
1200.0
hPa
Air Density (act)
310
0.000
3.000
kg/m3
Rel. Air Pressure (act)
305
300.0
1200.0
hPa
Rel. Air Pressure (min)
325
300.0
1200.0
hPa
Rel. Air Pressure (max)
345
300.0
1200.0
hPa
Rel. Air Pressure (avg)
365
300.0
1200.0
hPa
Buffer ‘0’
Buffer ‘1’
Example: Request with M command
0M3!
00009
0D0!
0+1001.0+1000.0+1002.0+1001.0+1.119
0D1!
0+1017.0+1016.0+1018.0+1017.0
Example: Request with C command
0C3!
000009
0D0!
0+1001.0+1000.0+1002.0+1001.0+1.119
0D1!
0+1017.0+1016.0+1018.0+1017.0
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
111
Operating Manual
Smart Weather Sensor
19.6.5.4 Buffer Assignment Additional Measurement Commands M4 / C4: Wind
Device configured for measurement values in metric units:
Measurement Value
UMB
Channel
Min
Max
Unit
Wind Speed (act)
400
0.0
75.0
m/s
Wind Speed (min)
420
0.0
75.0
m/s
Wind Speed (max)
440
0.0
75.0
m/s
Wind Speed (avg)
460
0.0
75.0
m/s
Wind Speed (vct)
480
0.0
75.0
m/s
Wind Direction (act)
500
0.0
359.9
°
Wind Direction (min)
520
0.0
359.9
°
Wind Direction (max)
540
0.0
359.9
°
Wind Direction (vct)
580
0.0
359.9
°
Wind Direction corr. (act)
502
0.0
359.9
°
Wind Quality
805
0.0
100.0
Wind Chill Temperature (act)
111
-60.0
70.0
°C
Wind Speed Standard Dev.*
403
0.0
60.0
m/s
Wind Direction Standard Dev.*
503
0.0
359.9
°
Buffer ‘0’
Buffer ‘1’
Buffer ‘2’
Device configured for measurement values in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Wind Speed (act)
410
0.0
167.8
mph
Wind Speed (min)
430
0.0
167.8
mph
Wind Speed (max)
450
0.0
167.8
mph
Wind Speed (avg)
470
0.0
167.8
mph
Wind Speed (vct)
490
0.0
167.8
mph
Wind Direction (act)
500
0.0
359.9
°
Wind Direction (min)
520
0.0
359.9
°
Wind Direction (max)
540
0.0
359.9
°
Wind Direction (vct)
580
0.0
359.9
°
Wind Direction corr. (act)
502
0.0
359.9
°
Wind Quality
805
0.0
100.0
Wind chill Temperature (act)
116
-76.0
158.0
°F
Wind Speed Standard Dev.*
413
0.0
167.8
mph
Wind Direction Standard Dev.*
503
0.0
359.9
°
Buffer ‘0’
Buffer ‘1’
Buffer ‘2’
*) Note: Std.Dev. values will be available after the first request. See p. 11.
112
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.6.5.5 Buffer Assignment Additional Measurement Commands M5 / C5: Compass
Device configured for measurement values in metric or US units:
Measurement Value
UMB
Channel
Min
Max
Unit
510
0.0
359.0
°
Buffer ‘0’
Compass (act)
Example: Request with M command
0M5!
00001
0D0!
0+348.0
Example: Request with C command
0C5!
000001
0D0!
0+348.0
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
113
Operating Manual
Smart Weather Sensor
19.6.5.6 Buffer Assignment Additional Measurement Commands M6 / C6:
Precipitation
Device configured for measurement values in metric units:
Measurement Value
UMB
Channel
Min
Max
Unit
Precip. Amount absolute
620
0.0
100000.0
mm
Precip. Amount difference
625
0.00
100000.00
mm
Precipitation Intensity
820
0.0
200.0
mm/h
Precipitation Type
700
0, 40, 60, 70 (67, 69, 90)*
Buffer ‘0’
Buffer ‘1’ (WS401-UMB, WS601-UMB only)
reserved
reserved
reserved
reserved
reserved
)* additional precipitation types: WS100-UMB only
Example: Request with M command
0M6!
00009
0D0!
0+1324.5+1.10+4.4+60
0D1!
0+603.5+562.4+847.4+623.8+1
Device configured for measurement values in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Precip. Amount absolute
640
0.000
3937.000
In
Precip. Amount difference
645
0.0000
3937.0000
In
Precipitation Intensity
840
0.000
7.874
in/h
Precipitation Type
700
0, 40, 60, 70 (67, 69, 90)*
Buffer ‘0’
Buffer ‘1’ (WS401-UMB, WS601-UMB only)
reserved
reserved
reserved
reserved
reserved
)* additional precipitation types: WS100-UMB only
114
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.6.5.7 Buffer Assignment Additional Measurement Commands M7 / C7: Global
Radiation, Lightning Detection (WS100-UMB: Drop Diameter Distribution)
Assignment for WS30x-UMB, WS50x-UMB, WS700-UMB, WS800-UMB
Device configured for measurement values in metric units:
Measurement Value
UMB
Channel
Min
Max
Unit
Global Radiation (act)
900
0.0
2000.0 *)
W/m²
Global Radiation (min)
920
0.0
2000.0 *)
W/m²
Global Radiation (max)
940
0.0
2000.0 *)
W/m²
Global Radiation (avg)
960
0.0
2000.0 *)
W/m²
Lightning Events (minute)
617
255
Lightning Events (Intervall)
677
999
Buffer ‘0’
Buffer ‘1’ (WS800-UMB only)
reserved
reserved
reserved
Buffer ‘2’ (WS800-UMB only)
reserved
*) Until device version .49 / .212 / Firmware v5.6: 1400.0 W/m
Example: Request with M Command
0M7!
00004
0D0!
0+780.0+135.0+920.0+530.0
Device configured for measurement values in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
Global Radiation (act)
900
0.0
2000.0 *)
W/m²
Global Radiation (min)
920
0.0
2000.0 *)
W/m²
Global Radiation (max)
940
0.0
2000.0 *)
W/m²
Global Radiation (avg)
960
0.0
2000.0 *)
W/m²
Lightning Events (minute)
617
255
Lightning Events (Intervall)
677
999
Buffer ‘0’
Buffer ‘1’ (WS800-UMB only)
reserved
reserved
reserved
Buffer ‘2’ (WS800-UMB only)
reserved
*) Until device version .49 / .212 / Firmware v5.6: 1400.0 W/m
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
115
Operating Manual
Smart Weather Sensor
Assignment for WS100-UMB, C7 Request only
Device configured for measurement values in metric or US units:
Messgröße
UMBKanal
Min
Max
Einheit
Total precipitation particles
4600
9999999
Event
Total drops
4601
9999999
Event
Drizzle particles
4602
65535
Event
Snow particles
4603
65535
Event
Hail particles
4604
65535
Event
Drop class 0
4620
65535
Event
Drop class 1
4621
65535
Event
Drop class 2
4622
65535
Event
Drop class 3
4623
65535
Event
Drop class 4
4624
65535
Event
Drop class 5
4625
65535
Event
Drop class 6
4626
65535
Event
Drop class 7
4627
65535
Event
Drop class 8
4628
65535
Event
Drop class 9
4629
65535
Event
Drop class 10
4630
65535
Event
Drop class 11
4631
65535
Event
Puffer ‘0’
Puffer ‘1’
116
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.6.5.8 Buffer Assignment Additional Measurement Commands M8 / C8: External
Temperature
Device configured for measurement values in metric units:
Measurement Value
UMB
Channel
Min
Max
Unit
101
-40.0
80.0
°C
Buffer ‘0’
External Temperature (act)
Example: Request with M Command
0M8!
00001
0D0!
0+13.5
Device configured for measurement values in US units:
Measurement Value
UMB
Channel
Min
Max
Unit
106
-40.0
176.0
°F
Buffer ‘0’
External Temperature (act)
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
117
Operating Manual
Smart Weather Sensor
19.6.6 Message Device Identification
The device responds to the identification request with following message (example for SDI12 device address ‘0’:
0I!
013Lufft.deWSx00ynnn
x: device type (4, 5, 6, 2, 3 )
y: Metric / US units ( m = metric, u = US )
nnn: Software version
i.e. for a WS600-UMB, configured for US units:
0I!
013Lufft.deWS600u022
19.6.7 Message Verification
The command verification aV! is used to evaluate status information of the device. The
device responds with
a0005
WS700/800-UMB: a0006
to the request, i.e. 5 (6) values are available in the buffers.
The first 3 (4) “measurement values”, transmitted in buffer ‘0’ contain the status information
of the measurement channels.
The status data of the channels are assembled to form “fake measurement values”, where
each digit represents one status. See below for the coding of states. Generally each sensor
has two status values, one for the direct value and another for the measurement value buffer
used for the evaluation of the average, min, and max values.
The last two values, transmitted in buffer ‘1’, show the heating temperatures of wind and
precipitation sensor.
Buffer ‘0’
Status group1: +nnnn
Air temperature, air temperature buffer, dew point, dew point
buffer
Status group1: +nnnnnn
(WS401 / WS601 only)
Air temperature, air temperature buffer, dew point, dew point
buffer, reserved, reserved
Status group 2: +nnnnnn
Rel. Humidity, rel. Humidity buffer, abs. Humidity, abs
humidity buffer, mixing ration, mixing ration buffer
Status group 3: +nnnnnn
Air pressure, air pressure buffer, wind, wind buffer,
compass, precipitation
(WS301/501 transmits the global radiation status instead of
the precipitation status)
Status group 4: +nnnn
(WS700-UMB, WS800-UMB
only)
Global radiation status, global radiation buffer status,
lightning detector status, lightning detector buffer status
Buffer ‘1’, device configured for metric units
Measurement value
UMB
Channel
min
max
Unit
Heating temp. Wind sensor
112
-50
+150
°C
Heating temp. Precip. sensor
113
-50
+150
°C
Buffer ‘1’, device configured for US units
118
Heating temp. Wind sensor
117
-58
+302
°F
Heating temp. Precip. sensor
118
-58
+302
°F
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
Sensor status codes:
Sensor status
Code
OK
UNGLTG_KANAL
E2_CAL_ERROR
E2_CRC_KAL_ERR
FLASH_CRC_ERR
FLASH_WRITE_ERR
FLASH_FLOAT_ERR
MEAS_ERROR
MEAS_UNABLE
INIT_ERROR
VALUE_OVERFLOW
CHANNEL_OVERRANGE
VALUE_UNDERFLOW
CHANNEL_UNDERRANGE
BUSY
other sensor status
Example (WS600-UMB, SDI-12 Address ‘0’, no error):
0V!
00005
0D0!
0+0000+000000+00000
0D1!
0+73.0+65.3
Example (WS600-UMB, SDI-12 Address ‘0’, compass failure):
0V!
00005
0D0!
0+0000+000000+000030
0D1!
0+73.0+65.3
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
119
Operating Manual
Smart Weather Sensor
19.6.8 Message Change of Unit System
The command is used to change the unit system used for the SDI12 data between metric
and US units. It is implemented as manufacturer specific X command.
Command:
aXU!
Response:
u:
m:
aU
US units
metric units
Example: change to metric units, SDI-12 address ‘0’
0XUm!
0Um
19.6.9 Message: Setting of the Averaging Interval Length
The avg, min, max and vct values of the measurement values are evaluated over a floating
interval with a length of 1 to 10 min. The length of this interval can be adjusted separately for
the groups temperature / humidity, air pressure and wind. (The averaging algorithm is not
applied to precipitation and compass).
Command:
aXA+nn!
t:
Temperature and Humidity
p:
Air pressure
w:
Wind
r:
Global radiation
nn:
Interval in minutes, valid range: 1 bis 10
Response:
aXA+nn
The response to the attempt of setting of an invalid interval length is
aXAf
Example: Setting the interval for temperature and humidity to 5 minutes
0XAt+5!
0XAt+5
19.6.10 Message: Setting of the Local Altitude
For the calculation of the relative air pressure the local altitude of the device is required.
Command:
aXH+nnnn!
nnnn: local altitude of the sensor in m
Response:
aXH+nnnn
The response to the attempt of setting of an invalid altitude (-100 < altitude < 5000) is
aXHf
Example: The altitude of the installation location is 135m above sea level
0XH+135!
0XH+135
120
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.6.11 Setting of the Local Magnetic Declination
For exact compass heading the local magnetic declination must be set.
Command:
aXD+nnn.n!
nnn.n: local magnetic declination at installation site in ° *)
Response:
aXD+nnn.n
The response to the attempt of setting of an invalid altitude (-180.0
Example: The declination at the installation location is -5.3°
0XD-5.3!
0XD-5.3
*) The magnetic declination is available from various web sites, e.g.
http://www.ngdc.noaa.gov/geomag-web/#declination
19.6.12 Message: Activation / Deactivation of Compass Correction
The correction of the wind direction by the compass bearing can be activated or deactivated.
Command:
aXW!
c:
wind direction is corrected by the compass bearing
u:
wind direction is not corrected
Response:
aXW
The response to the attempt of setting an invalid option is
aXWf
Example: Compass correction of wind direction is activated
0XWc!
0XWc
19.6.13 Message: Setting the Power Saving Mode
For installations with limited power supply the Smart Weather Sensor may be operated in
power saving mode (see Chap. 40).
Note: Operation in power saving mode has some functional restrictions!
Command:
aXL!
n:
Normal Operation
s:
Power saving mode 1 (Heating/Fan off)
w:
Power saving mode 2 (Sleep mode)
Response:
aXL
The response is followed by the device reset, i.e. the device will be offline for a few seconds.
The response to the selection of an invalid option or of an invalid combination of mode and
device model is
aXLf
Example: The device shall be set to power saving mode 2
0XLw!
0XLw
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
121
Operating Manual
Smart Weather Sensor
19.6.14 Message: Setting the Heating Mode
The heating of the precipitation and the wind sensors can be configured in different operation
modes (see chapter 10.4). Depending on the actual variant of the Smart Weather Sensor
(WS100-UMB ...WS800-UMB) only certain combinations of operating modes are available.
The Smart Weather Sensor evaluates the valid combinations from the device heating mode
requested in the command automatically.
Command:
aXMn!
n:
Heating Operating Mode (0: Automatic, 1: Mode 1, 2: Off, 3: Eco Mode 1)
Response:
aXMnm
n:
Selected Heating Mode Wind Sensor
m:
Selected Heating Mode Precipitation Sensor
The response to the attempt of setting an invalid operation mode is
aXMf
Example: A WS400-UMB shall be set to Mode 1
0XM1!
0XM21
As the WS400-UMB does not have a wind sensor the heating mode wind is automatically set
to 2 (= off).
0XD+633.0
122
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.6.15 Message: Setting of the Rain Gauge Resolution
The resolution of the tipping bucket rain gauge of WS401-UMB and WS601-UMB, as well as
the resolution of an optional external rain gauge connected to a model without internal
precipitation measurement can be mechanically adjusted (see p. 35). The mechanical
resolution must be set in the sensor configuration.
Command:
aXK+n!
n:
resolution of the rain gauge in 1/10mm, valid settings 1, 2, 5, 10
(0.1mm, 0.2mm, 0.5mm, 1.0mm)
Response:
aXK+n
The response to the attempt of setting of an invalid resolution is
aXKf
Example: The mechanical resolution of the rain gauge is 0.2mm
0XK+2!
0XK+2
19.6.16 Message: Clearing the Absolute Precipitation Amount
The command clears the accumulated absolute precipitation amount to 0.0mm. At the same
time a device reset is applied.
Command:
aXC!
Response:
aXCok
The response is followed by the device reset, i.e. the device will be offline for a few seconds.
Example:
0XC!
0XCok
19.6.17 Message: Device Reset
The command initiates a device reset.
Command:
aXR!
Response:
aXRok
The response is followed by the device reset, i.e. the device will be offline for a few seconds.
Example:
0XR!
0XRok
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
123
Operating Manual
Smart Weather Sensor
19.7 Communication in Modbus Mode
For a simpler integration of WS family Smart Weather Sensors into a PLC environment the
Modbus communication protocol has been made available.
Measurement values are mapped to Modbus Input Registers. The range of values available
is basically the same as for the UMB protocol, including different unit systems.
In the interest of simple and safe integration the use of register pairs for floating point values
or 32 bit integers, which is not part of the Modbus standard, has not been applied. All
measurement values are mapped to 16bit integers using suitable scaling factors.
19.7.1 Modbus Communication Parameters
The Smart Weather Sensor can be configured for MODBUS-RTU or for MODBUS-ASCII.
The base configuration has to be done using the UMB Config Tool.
When selecting MODBUS RTU or MODBUS-ASCII with the UMB Config Tool,
communication parameters 19200 Bd, even parity, will be preselected.
Modbus operating modes:
MODBUS-RTU, MODBUS-ASCII
Baud rate:
19200 (9600, 4800 or lower)
Interface Setting
8E1, 8N1, 8N2
NOTE: The Modbus communication has been tested for a poll rate of 1 sec. The proper
function of the Smart Weather Sensor with higher Modbus poll rates has not been tested.
We suggest to set the poll rate to 10 sec or slower, as, with the exception of the channels
„wind speed / wind directions fast“, which are provided for special purposes, the update rate
of the data is >= 10sec. Anyway for most of the weather data significant changes have tob e
expected more in the range of minutes.
19.7.2 Addressing
The Modbus address is deducted from the the UMB device ID (see Chap. 19.3.2).
A device with UMB device ID 1 also has the UMB address 1, etc..
The valid address range of Modbus from 1 to 247 is smaller than that of the UMB device IDs.
If a UMB device ID > 247 has been selected, the Modbus address will be set to 247.
19.7.3 Modbus Functions
The functions of conformance class 0 and 1 have been implemented as far as they are
applicable for the Smart Weather Sensor, i.e. all functions operating on register level.
Conformance Class 0
0x03
Read Holding Registers
Selected configuration settings
0x16
Write Multiple Registers
Selected configuration settings
Conformance Class 1
0x04
Read Input Registers
Measurement values and status information
0x06
Write Single Register
Selected configuration settings
0x07
Read Exception Status
Currently not used
Diagnostics
0x11
124
Report Slave ID
(responds also to broadcast address)
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.7.3.1 Function 0x03 Read Holding Registers
The Holding Registers are used to make a selected set of adjustable parameters available
for Modbus access. As for the measurement values the parameters are mapped to 16bit
integers.
Reg.
No.
Reg.
Addr
Function
Values
Scale
Local Altitude
Altitude in m, for calculation of relative air pressure
Value range -100 … 5000
1.0
Deviation
Local deviation for the correction of compass heading.
10.0
Value range -3599 … 3599
(equalling -359.9° … +359.9°)
Averaging Interval
TFF
Interval for averaging and min/max evaluation in minutes
Averaging Interval
Air Pressure
Interval for averaging and min/max evaluation in minutes
Averaging Interval
Wind
Interval for averaging and min/max evaluation in minutes
Averaging Interval
Global Radiation
Interval for averaging and min/max evaluation in minutes
Heating Mode
High-Byte: Heating Mode Wind
Low-Byte Heating Mode R2S
1.0
Value range 1 … 10
1.0
Value range 1 … 10
1.0
Value range 1 … 10
1.0
Value range 1 … 10
Value range of each byte 0 … 3
(Details s. 10.5)
Reset abs. Rain
(Function only when writing to the register, reading will
give 0 always)
Device reset
(Function only when writing to the register, reading will
give 0 always)
Heating Modes (see 10.5):
Automatic
Mode 1
Off
Eco 1
19.7.3.2 Function 0x06 Write Holding Register, 0x10 Write Multiple Registers
By writing into the holding registers selected parameters of the Smart Weather Sensor can
be adjusted through Modbus.
Register assignment see19.7.3.1
Local altitude, compass deviation and averaging intervals are set by writing the new values
into the related registers. Depending on the selected register the value has to be scaled by
the factor given in the table:
Example: for compass deviation the table shows a scaling factor of 10.0. If the deviation is
4.8° a value of 48 shall be written into register 2 (reg.addr. 1).
The transmitted values will be checked for plausibility. Illegal values will not be accepted and
cause a Modbus exception.
When writing the value 0x3247 (12871d) to register no. 8 (reg. addr. 7) the stored absolute
rain amount will be set to 0. Subsequently a device reset will be initiated.
When writing the value 0x3247 (12871d) to register no. 9 (reg. addr. 8) a device reset will be
initiated.
Setting of the heating mode:
The wind sensor heating mode is coded into the high byte of the 16bit register no. 7, the
precipitation sensor heating mode into the low byte of this register
Example :
Heating mode wind: Mode 1 (Code 1)
Heating mode precipitation: Off (Code 2)
Write to register 7 (reg. addr. 6):
0x0102 (=258d)
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
125
Operating Manual
Smart Weather Sensor
Setting for minimum power consumption, both heatings off (Code 2):
Write to register 7 (reg. addr. 6):
0x0202 (=514d)
The factory setting for a WS600-UMB is automatic mode for both heatings, i.e. 0x0000.
When attempting to set a heating mode not supported by the individual device variant, e.g.
activating the precipitation heating of a device without precipitation sensor, the device will
automatically adjust the value written to the register, so that the value read back from the
register might be different from the written value.
126
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.7.3.3 Function 0x04 Read Input Registers
The input registers are containing the measurement values of the Smart Weather Sensor
and the related status information.
The measurement values are mapped to the 16bit registers using scaling factors (0 … max.
65530 for unsigned values, -32762 … 32762 for signed values).
Values 65535 (0xffff) resp. 32767 are used for the indication of erroneous or not available
measurement values. A more detailed specification of the error can be evaluated from the
status registers.
The assignment of values to the available register addresses (0 … 124) has been arranged
in a way so that the user can read the most frequently used data with few (ideally only one)
register block requests
Following blocks have been defined:
Status information
Frequently used values which are independent of the unit system (met./ imp.) in use
Frequently used values in metric units
Frequently used values in imperial units
Other measurement values
When using the metric unit system the first three blocks can the supply all data usually
required with one request.
There is no difference in the register assignment between the sub types of the WS family. If,
dependent on the type, some value is not available, this will be indicated by setting the
register to the error value.
For detailed information about measurement ranges, units etc. please refer to the related
description of the UMB channels (Chapter 6 and 19.1)
Reg.
No.
Reg.
Addr.
Value (UMB
Channel)
Range
Scaling Factor, Remarks
High Byte: WS-Type (2,3,4,5,6)
Low Byte: Software Version
Type coding, see below
Coding 4 bit per status, see
below
Status Information
Identification
Device Status
Sensor Status 1
Air temperature buffer, air temperature, dew
point buffer, dew point(high byte -> low byte,
see table below)
Sensor Status 2
Rel. humidity buffer, rel. humidity, abs.
Coding 4 bit per status, see
humidity buffer, abs. humidity(high byte -> low below
byte, see table below)
Sensor Status 3
Mixing ratio buffer, mixing ration, air press.
buffer, air press. (high byte -> low byte, see
table below)
Sensor Status 4
Wind buffer, wind, precipitation, compass(high Coding 4 bit per status, see
byte -> low byte, see table below)
below
Sensor Status 5
Global radiation buffer, global radiation,
Coding 4 bit per status, see
reserved, reserved (high byte -> low byte, see below
table below)
Sensor Status 6
External temperature / external rain gauge,
lightning sensor, lightning sensor buffer (see
table below)
Reserve
10
Coding 4 bit per status, see
below
Coding 4 bit per status, see
below
Diagnostic: run time in 10sec steps
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
127
Operating Manual
Smart Weather Sensor
Reg.
No.
Reg.
Addr.
Value (UMB
Channel)
Range
Scaling Factor,
signed/unsigned,
Remarks
Values Independent of the Unit System
128
11
10
200
Relative Humidity (act.)
Factor 10, s
12
11
220
Relative Humidity (min.)
Factor 10, s
13
12
240
Relative Humidity (max.)
Factor 10, s
14
13
260
Relative Humidity (avg.)
Factor 10, s
15
14
305
Rel. Air Pressure (act.)
Factor 10, s
16
15
325
Rel. Air Pressure (min.)
Factor 10, s
17
16
345
Rel. Air Pressure (max.)
Factor 10, s
18
17
365
Rel. Air Pressure (avg.)
Factor 10, s
19
18
500
Wind Direction (act.)
Factor 10, s
20
19
520
Wind Direction (min.)
Factor 10, s
21
20
540
Wind Direction (max.)
Factor 10, s
22
21
580
Wind Direction (vct.)
Factor 10, s
23
22
501
Wind Direction fast
Factor 10, s
24
23
502
Wind Direction compass corr.
Factor 10, s
25
24
510
Compass
Factor 10, s
26
25
700
Precipitation Type
Factor 1, s
27
26
805
Wind Measurement Quality
Factor 1, u
28
27
900
Global Radiation (act.)
Factor 10, s
29
28
920
Global Radiation (min.)
Factor 10, s
30
29
940
Global Radiation (max.)
Factor 10, s
31
30
960
Global Radiation (avg.)
Factor 10, s
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
Reg.
No.
Reg.
Addr.
Value (UMB
Channel)
Range
Scaling Factor,
signed/unsigned Remarks
Values in Metric Units
32
31
100
Air Temperature °C (act.)
Factor 10, s
33
32
120
Air Temperature °C (min.)
Factor 10, s
34
33
140
Air Temperature °C (max.)
Factor 10, s
35
34
160
Air Temperature °C (avg.)
Factor 10, s
36
35
110
Dew Point °C (akt.)
Factor 10, s
37
36
130
Dew Point °C (min.)
Factor 10, s
38
37
150
Dew Point °C (max.)
Factor 10, s
39
38
170
Dew Point °C (avg.)
Factor 10, s
40
39
111
Wind Chill-Temperature °C
Factor 10, s
41
40
112
Heating Temperature Wind °C
Factor 10, s
42
41
113
Heating Temperature R2S °C
Factor 10, s
43
42
400
Wind Speed m/s (akt.)
Factor 10, s
44
43
420
Wind Speed m/s (min.)
Factor 10, s
45
44
440
Wind Speed m/s (max.)
Factor 10, s
46
45
460
Wind Speed m/s (avg.)
Factor 10, s
47
46
480
Wind Speed m/s (vct.)
Factor 10, s
48
47
401
Wind Speed fast m/s
Factor 10, s
49
48
620
Precipitation abs. mm
Factor 100, u, limited to
655.34mm
50
49
625
Precipitation diff. mm
Factor 100, u, limited to
100.00mm
51
50
820
Precipitation intens. mm/h
Factor 100, u, limited to
200.00mm/h
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
129
Operating Manual
Smart Weather Sensor
Reg.
No.
Reg.
Addr.
Value (UMB
Channel)
Range
Scaling Factor,
signed/unsigned Remarks
Values in US Units
130
52
51
105
Air Temperature °F (act.)
Factor 10, s
53
52
125
Air Temperature °F (min.)
Factor 10, s
54
53
145
Air Temperature °F (max.)
Factor 10, s
55
54
165
Air Temperature °F (avg.)
Factor 10, s
56
55
115
Dew Point °F (act.)
Factor 10, s
57
56
135
Dew Point °F (min.)
Factor 10, s
58
57
155
Dew Point °F (max.)
Factor 10, s
59
58
175
Dew Point °F (avg.)
Factor 10, s
60
59
116
Wind Chill-Temperature °F
Factor 10, s
61
60
117
Heating Temperature Wind °F
Factor 10, s
62
61
118
Heating Temperature R2S °F
Factor 10, s
63
62
410
Wind Speed mph (act.)
Factor 10, s
64
63
430
Wind Speed mph (min.)
Factor 10, s
65
64
450
Wind Speed mph (max.)
Factor 10, s
66
65
470
Wind Speed mph (avg.)
Factor 10, s
67
66
490
Wind Speed mph (vct.)
Factor 10, s
68
67
411
Wind Speed fast mph
Factor 10, s
69
68
640
Precipitation abs. In
Factor 1000, u, limited to 25.800
in
70
69
645
Precipitation diff. in
Factor 10000, u, limited to
3.9370in
71
70
840
Precipitation Intens. in/h
Factor 10000, u, limited to
6.5534 in
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
Reg.
No.
Reg.
Addr.
72
71
73
Value (UMB
Channel)
Range
Scaling Factor,
signed/unsigned, Remarks
205
Absolute Humidity (act.)
Factor 10, s
72
225
Absolute Humidity (min.)
Factor 10, s
74
73
245
Absolute Humidity (max.)
Factor 10, s
75
74
265
Absolute Humidity (avg.)
Factor 10, s
76
75
210
Mixing Ratio (act.)
Factor 10, s
77
76
230
Mixing Ratio (min.)
Factor 10, s
78
77
250
Mixing Ratio (max.)
Factor 10, s
79
78
270
Mixing Ratio (avg.)
Factor 10, s
80
79
300
Abs. Air Pressure (act.)
Factor 10, s
81
80
320
Abs. Air Pressure (min.)
Factor 10, s
82
81
340
Abs. Air Pressure (max.)
Factor 10, s
83
82
360
Abs. Air Pressure (avg.)
Factor 10, s
84
83
405
Wind Speed km/h (act.)
Factor 10, s
85
84
425
Wind Speed km/h (min.)
Factor 10, s
86
85
445
Wind Speed km/h (max.)
Factor 10, s
87
86
465
Wind Speed km/h (avg.)
Factor 10, s
88
87
485
Wind Speed km/h (vct.)
Factor 10, s
89
88
415
Wind Speed kts (act.)
Factor 10, s
90
89
435
Wind Speed kts (min.)
Factor 10, s
91
90
455
Wind Speed kts (max.)
Factor 10 , s
92
91
475
Wind Speed kts (avg.)
Factor 10, s
93
92
495
Wind Speed kts (vct.)
Factor 10, s
94
93
406
Wind Speed fast km/h
Factor 10, s
95
94
416
Wind Speed fast kts
Factor 10, s
96
95
403
Wind Speed Std. Dev. m/s *
Factor 100, s
97
96
413
Wind Speed Std. Dev. Mph *
Factor 100, s
98
97
503
Wind Dir. Standard Dev.*
Factor 100, s
99
98
114
Wet Bulb Temp. °C (act)
Factor 10, s
100
99
119
Wet Bulb Temp. °F (act)
Factor 10, s
101
100
215
Specific Enthalpy (act)
Factor 10, s
102
101
310
Air Density (act)
Factor 1000, s
Further Values
*) Note: Standard deviation values are available after the first request. Please see p. 11
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
131
Operating Manual
Smart Weather Sensor
Reg.
No.
Reg.
Addr.
Value (UMB
Channel)
Range
Scaling Factor,
signed/unsigned, Remarks
Further Values
103
102
710
reserved
Factor 1, s
104
103
730
reserved
Factor 1, s
105
104
750
reserved
Factor 1, s
106
105
770
reserved
Factor 1, s
107
106
711
reserved
Factor 1, s
108
107
101
External Temperature °C (act)
Factor 10, s
109
108
109
External Temperature °F (act)
Factor 10, s
110
109
806
Wind Value Quality (fast)
Factor 1, u
111
110
617
Lightning Events (minute)
Factor 1, u
112
111
677
Lightning Events (Intervall)
Factor 1, u
Reserved
Service Channels
Air temperature (WS100-UMB only, no radiation shield)
Reg.
No.
Reg.
Addr.
Value (UMB
Channel)
Range
Scaling Factor,
signed/unsigned Remarks
Values in Metric Units
132
150
149
4100
Air Temperature °C (act.)
Factor 10, s
151
150
4120
Air Temperature °C (min.)
Factor 10, s
152
151
4140
Air Temperature °C (max.)
Factor 10, s
153
152
4160
Air Temperature °C (avg.)
Factor 10, s
154
153
4105
Air Temperature °F (act.)
Factor 10, s
155
154
4125
Air Temperature °F (min.)
Factor 10, s
156
155
4145
Air Temperature °F (max.)
Factor 10, s
157
156
4156
Air Temperature °F (avg.)
Factor 10, s
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
Drop Diameter Distribution (WS100-UMB only)
Reg.
No.
Reg. Value (UMB Channel)
Addr.
Range
Scaling Factor,
signed/unsigned,
Remarks
130
129
4600
Total particles
Faktor 1, u
131
130
4601
Total drops
Faktor 1, u
132
131
4602
Drizzle particles
Faktor 1, u
133
132
4603
Snow particles
Faktor 1, u
134
133
4604
Hail particles
Faktor 1, u
135
134
4620
Drop class 0
Faktor 1, u
136
135
4621
Drop class 1
Faktor 1, u
137
136
4622
Drop class 2
Faktor 1, u
138
137
4623
Drop class 3
Faktor 1, u
139
138
4624
Drop class 4
Faktor 1, u
140
139
4625
Drop class 5
Faktor 1, u
141
140
4626
Drop class 6
Faktor 1, u
142
141
4627
Drop class 7
Faktor 1, u
143
142
4628
Drop class 8
Faktor 1, u
144
143
4629
Drop class 9
Faktor 1, u
145
144
4630
Drop class 10
Faktor 1, u
146
145
4631
Drop class 11
Faktor 1, u
Reserve
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
133
Operating Manual
Smart Weather Sensor
Smart Weather Sensor Type Code
WS100-UMB
WS303-UMB
33
WS200-UMB
WS304-UMB
43
WS300-UMB
WS310-UMB
93
WS400-UMB
WS501-UMB
15
WS500-UMB
WS502-UMB
25
WS600-UMB
WS503-UMB
35
WS700-UMB
WS504-UMB
45
WS800-UMB
WS510-UMB
95
WS301-UMB
13
WS401-UMB
14
WS302-UMB
23
WS601-UMB
16
Sensor Status:
Each register hoIds 4 sensor status coded with 4 bits per status, so that together they build
one 16bit number. The sequence defined in the table above is to understand as from most
significant half byte to least significant half byte. Most of the sensors have two status values,
one for the sensor itself and the current measurement value, another one for the buffer, from
which average, min. And max values are evaluated.
Assignment of Status Information to Status Register
Register
Byte
High
Sensor Status 1
Low
High
Sensor Status 2
Low
High
Sensor Status 3
Low
High
Sensor Status 4
Low
High
Sensor Status 5
Low
High
Sensor Status 6
Low
134
HalfByte
Status
High
Temperature Buffer
Low
Temperature
High
Dewpoint Buffer
Low
Dewpoint
High
Rel. Humidity Buffer
Low
Rel. Humidity
High
Abs. Humidity Buffer
Low
Abs. Humidity
High
Mixing Ratio Buffer
Low
Mixing Ratio
High
Air Pressure Buffer
Low
Air Pressure
High
Wind Buffer
Low
Wind
High
Precipitation
Low
Compass
High
Global Radiation Buffer
Low
Global Radiation
High
reserved
Low
reserved
High
Low
External Temperature
High
Lightning Sensor Buffer
Low
Lightning Sensor
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
Low Byte
High
Low
Temperatur
Dew pointBuffer
Dew point
High Byte
High
Low
Temperatur
e-Buffer
Example Sensor Status 1:
Temperature buffer status, temperature status, dewpoint buffer status, dewpoint status
The example values above (for illustration only, the given combination will not occur in
reality) are combined to the register value 0x5307 = 21255.
The single status are retrieved from the register as integer part of
Status 1
= register / 4096
Status 2
= (register / 256) AND 0x000F
Status 3
= (register / 16) AND 0x000F
Status 4
= register AND 0x000F
Following table shows the status coding:
Coding of Sensor Status:
Sensor State
Code
OK
UNGLTG_KANAL
E2_CAL_ERROR
E2_CRC_KAL_ERR
FLASH_CRC_ERR
FLASH_WRITE_ERR
FLASH_FLOAT_ERR
MEAS_ERROR,
MEAS_UNABLE
INIT_ERROR
VALUE_OVERFLOW
CHANNEL_OVERRANGE
VALUE_UNDERFLOW
CHANNEL_UNDERRANGE
BUSY
Other Sensor State
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
135
Operating Manual
Smart Weather Sensor
19.8 Communication: XDR Protocol
Note: XDR protocol is not available for WS100-UMB.
The XDR protocol allows to transmit a selected data set of the Smart Weather Sensor in a
NMEA compatible format. The data telegram can be transmitted on request, or the Smart
Weather Sensor can be set into auto transmit mode, where the data telegram will be
triggered automatically at an selectable interval.
A set of ASCII configuration messages allows to apply some configuration settings without
leaving the XDR protocol.
For configuration settings exceeding this command set use the UMB Config Tool. To change
into the UMB protocol a UMB message must be addressed to the device within 5 seconds
after power up or reset.
Figure 45: Sensor
Configuration XDR
Protocol
Automatic telegram output
Air pressure mode
Output Interval NMEA
NMEA talker device identifier
136
XDR protocol selected
activate continous mode (automatic result
message transmission)
select absolute or relative air pressure for the
measurement data message (seconds)
Interval for automatic result message transmission
Select the Talker ID part of the NMEA telegram
header
G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Operating Instructions
Smart Weather Sensor
19.8.1 Basic Interface Properties
Baud rate configurable from 1200bps to 57600bps, character format 8 bits, no parity,
1 stop bit (8N1).
Unit ID equal to UMB device ID, but limited to 98. 99 is the broadcast ID
Data output on request or continuously (configurable)
Commands and messages use strictly ASCII text mode
19.8.2 Message Format for Commands and Responses
Byte
'*'
Start Character
1,2
'01'
Destination ID
3,4
'00'
Source ID
5 ... n
n+1, n+2
Command Data (min. 2)
Termination Characters
The command data field always starts with the 2-character command identifier, optionally
followed by a parameter, starting with '='.
Currently implemented commands are
P9
single measurement XDR format
PP
start continuous measurement XDR format
PB
single measurement PWSD format
PC
start continuous measurement PWSD format
GW
option: add MWD sentence (wind data) to XDR format
MI
continuous measurement interval
J3
pressure mode (absolute air pressure / relative air pressure)
JS
pressure sensor elevation
JW
spot or average output of wind data
BR
baud rate
ID
unit ID
NH
message prefix
If the device receives an invalid command (missing start or termination character, invalid ID,
invalid structure etc.), it will not respond.
If a setting command contains an invalid parameter value, the device will not respond.
Setting commands must usually be preceded by the “Write Enable” command EW. This
command does not generate a response, and may be, different from other commands,
transmitted without message terminators (