G4S Technology S874 S874 MiFare Wallplate Card Reader User Manual

G4S Technology Limited S874 MiFare Wallplate Card Reader

user manual

Mount the backplate using countersunk headed screws adjacent to the opening edge of the door and at a convenient height (recommended height is 5' (1.5m) to top of unit).If fixing hole ’A’ is used then the breakout must be removed and the screw must not protrude.Feed the cable from the controller through the backplate.If the wall tamper function is to be used then the small hole in breakout ‘B’ may be used to mark the position of the wall screw before the breakout is removed.  An appropriate wall screw should then be adjusted in height to protrude through the hole to activate the tamper lever.21Mount the BackplateReader ConnectionsThe  S874  is  a reader  can  be  set  to  use  Wiegand  or The S874 reader will read smartMAX encoded MIFARE cards and card serial numbers from most ISO 14443A smart cards which have a 4-byte UID (User Identification).   The  reader  may  be  configured  to  read  other  card  types  by presenting a programming card to the reader during start up.For additional information regarding the installation, configuration and proper use of this product:SMS User Guide, P/N 9600-0429, M2150 Access Control Design Guide, P/N 9600-0420,  M2150  Intrusion  Guide,  P/N  9600-0540  and  M2150  UL1076 Compliance Manual, P/N 9600-0449.contactless  smart-card  reader,  with  LED’s  and  keypad.  The 20mA  current  loop  communications.The securing screw ‘C’ is integral to the backplate and is unscrewed via the small hole in the enclosure so that the screw head  locates in the counterbored holes on the inside of the enclosure.You should find that the backplate has holes for connection to most standard electrical backboxes.CABInstallation and User Instructions for S874 Keypad Readers0VRX+RX-TX+TX-12VController0VTX+TX-RX+RX-+VReader TB120mA current loop0VGreenData 0RedData 112VController0VGRN0+VUse Belden 9537 CableWiegandRED1Reader TB1Connect shield at controller end only.Connect shield at controller end only.Twisted pairs (use Belden 9503 Cables)Note: Use SW1 switch2 to select the communications mode (See Step 3).Note:1). Consult local AHJ (Authority Having Jurisdiction) when installing access control readers and locking mechanisms to any portal in an egress path.2). The use of Fail Closed / secure configuration shall be determined by local building codes and the local AHJ.3). Wiring methods shall be in accordance with NEC (National Electrical Code) ANSI/NFPA 70.4). The Wiegand connections are not allowed under UL1076 unless a separate tamper switch is provided.Slide the ferrite sleeve onto cable before wiring terminal block.  Ferrite to be placed 50mm (2") up cable and held in place with cable ties.Note: The FERRITE must be fitted!
Present the card face-on to the reader until you hear a "bleep". Cards can be presented in rapid succession; there is no need, for example, to wait for "GREEN LED’s" to disappear before presenting another.If the reader has been enabled for user-code mode at the controller, you can gain access by pressing the O key, entering your card number, then pressing the P key.                                     Please refer to M2150 Intrusion Guide, 9600-0540 for IDS Arm / Disarm procedure.9600-0596.  Installation  and  User  Instructions  for  S874  Keypad Readers, Issue 1.0x2 12th March 2012.   G4S Technology, 2012. FCC  Notice:  This  device  complies  with  Part  15  of  the  FCC  Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Any unauthorized modification to this device may void the authority of the user to operate it. All trademarks acknowledged.©LED Status IndicatorGREEN – The lock is released and you may open the door.RED – You do not have access rights to gain entry, or the reader did not read your card properly (in this case, present it again).YELLOW – Enter your PIN. If you make a mistake, the RED LED’s are momentarily displayed, followed by YELLOW LED’s, to prompt you to try again.SpecificationsInput voltage: 9-14Vdc. Input current:  120mA @ nom. 12Vdc.Operating temperature: 14 to 131°F (-10 to 55°C)Operating humidity: 15 to 90%, non-condensing.Maximum read range: 4" (100mm).Approvals:EN302291, EN3014894Using the ReaderSet SW1 switch2 (COM) to W for Wiegand communications, or C for 20mA current loop communications. Set SW1 switch1 F/B - Keypad audio feedback) to 1 for sound on, or 0 for sound off. 3Switch Settings

Navigation menu