G4S Technology Limited S874 Smart Card Reader User Guide

User Guide

Mount  the  backplate  using  countersunk  headed  screws adjacent to the opening edge of the door.If fixing hole ’A’ is used then the breakout must be removed and the screw must not protrude.Feed the cable from the controller through the backplate.If the wall tamper function is to be used then the small hole in breakout  ‘B’  may  be  used  to  mark  the  position  of  the  wall screw before the breakout is removed.   An appropriate wall screw should then be adjusted in height to protrude through the hole to activate the tamper lever.The  front  cover  is  secured  to  the  backplate  by UNSCREWING the securing screw ‘C’ via the small hole in the enclosure so  that the  screw  head  locates  in  the counterbored hole on the inside of the enclosure.The screw should not be removed from the backplate.2Mount the BackplateThe S874 is a contactless smart-card reader, with LED’s and keypad. The reader can be set to use Wiegand or The S874 reader will read smartMAX encoded MIFARE cards and card serial numbers from most ISO 14443A smart cards which have a 4-byte UID (User Identification).  The reader may be configured to read other card types by presenting a programming card to the reader during start up.For  additional  information  regarding  the  installation,  configuration  and proper use of this product:SMS User Guide, P/N 9600-0429, M2150 Access Control Design Guide, P/N 9600-0420, 20mA current loop communications.Installation and User Instructions for S874-EX Keypad Readers1Fit The Weather Proofing KitWhen mounting outside, the gasket kit must be fitted:a) Remove the backplate from the reader after screwing the securing screw ‘C’ fully IN.b) Position the gasket between the back plate and the mounting surface.Note: For UL listed applications, use only manufacturer provided gasket, P/N 87X-GASKET. You should find that the backplate has holes for connection to most standard electrical backboxes.CAB
4Reader LinksPresent the card face-on to the reader until you hear a "bleep".  Cards canbe presented in rapid succession; there is no need, for example, to wait for "GREEN LED’s" to disappear before presenting another.If the reader has been enabled for user-code mode at the controller, you can gain access by pressing the O key, entering your card number, then pressing the P key.When faulted, the reader can not accept a card read.  Check wiring for faults or replace reader.                       The reader is now working correctly. 9600-0596. Installation and User Instructions for S874-EX  Keypad Readers, Issue 1.0.125th September 2012.   G4S Technology, 2012. FCC  Notice:  This  device  complies  with  Part  15  of  the  FCC  Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)  this  device  must  accept  any interference received, including interference that may cause undesired operation.Any unauthorized modification to this device may void the authority of the user to operate it. All trademarks acknowledged.©LED Status IndicatorGREEN – The lock is released and you may open the door.RED – You do not have access rights to gain entry, or the reader did not read your card properly (in this case, present it again).YELLOW – Enter your PIN. If you make a mistake, the RED LED’s are momentarily displayed, followed by YELLOW LED’s, to prompt you to try again.SpecificationsInput voltage: 9-14Vdc. Input current:  120mA @ nom. 12Vdc.Operating temperature: -40 to 158°F (-40 to 70°C)Operating humidity: 15 to 90%, non-condensing.Maximum read range: 4" (100mm).Approvals: EN302291, EN3014895Using / Testing the ReaderSet SW1 switch2 (COM) to W for Wiegand communications, or C for 20mA current loop communications. Set SW1 switch1 (USER F/B - audio feedback) to 1 for sound on, or 0 for sound off. 3Reader Connections0VGreenData 0RedData 112VController0VGRN0+VWiegandRED1ReaderTB1Connect shield at controller end only.Note: Use SW1 switch2 to select the communications mode (See Step 5).Multi conductor (Use Belden 9537) or other UL Listed style 2464 (DUZX) cable.Note: The FERRITE must be fitted!Slide the ferrite sleeve onto cable before wiring terminal block.  Ferrite to be placed 50mm (2") up cable and held in place with cable ties.Maximum distance 75m0VRX+RX-TX+TX-12VController0VTX+TX-RX+RX-+VReaderTB120mA current loopConnect shield at controller end only.Twisted pairs (use Belden 9504) cable or other UL Listed style 2464 (DUZX) cable.Maximum distance 150m

Navigation menu