GE Healthcare 6960-MON Novii Intrapartum Maternal/Fetal monitor Pod User Manual 107 TF 100 USrev7 Novii Technical Datasheet
GE Healthcare Novii Intrapartum Maternal/Fetal monitor Pod 107 TF 100 USrev7 Novii Technical Datasheet
Contents
107-TF-100-USrev7_Novii Technical Datasheet
Novii Wireless Patch System Part of GE Healthcare The Monica Novii Wireless Patch System (“Novii”) Interface provides the opportunity to empower you and your patients by enhancing patient comfort & optimizing your workflow. It connects with your Corometrics 174 and 259cx series maternal/fetal monitors and the data flows seamlessly to your existing surveillance and archival system. Novii has three constituent parts, the Novii Patch, Novii Pod and Novii Interface. Patch Pod Novii Patch is a single-use, peel-and-stick disposable Novii Interface is a reusable part that translates Bluetooth part, which attaches to the woman’s abdomen using the data transmitted by the Novii Pod into signals of the correct comfortable adhesive foam pads. The patch incorporates ECG format to input your fetal monitor. The Novii Interface is electrode areas which pick up ECG and EMG signals from the connected to the CTG monitor via physical cables which skin surface and then transfer them to the Novii Pod. attach to the transducer inputs of the CTG monitor. The Novii Interface also has a touch screen to allow the user to Novii Pod is a reusable part which magnetically connects to configure the set-up and has two bays incorporated into its the Novii Patch to pick up the fetal and maternal ECG and EMG base for charging and pairing of the Novii Pods. signals and then filters, digitises and processes them in real time to extract the FHR, MHR & UA data. The Pod transmits this data via Bluetooth to the Novii Interface. Performance Specifications Novii Wireless Patch System System Components* Novii Interface 107-PT-001 Novii Interface Power Supply (USA) 107-PT-002-US Novii Interface Power Supply (INT) 107-PT-002 Monica CTG Cables - GE Corometrics DECG round grey connector 105-PT-102 - GE Corometrics MECG round green connector 105-PT-104 - GE Corometrics UA round white connector 105-PT-106 Novii Pods 107-PT-003 Novii Patch 107-PT-004 Novii User Manual 107-PT-005 Novii User Manual (CD) 100-PT-025 Novii Getting Started Guide 107-PT-006 Novii FHR Gaps Troubleshooting Guide 107-PT-008 3M Red Dot 2236 Skin Prep Tape 100-PT-007 Novii Patch Part Number Input Single Patch 107-PT-004 Box (10 patches) 107-PT-004-10 Box (50 patches) 107-PT-004-50 Electrophysiological signals picked up from the skin surface via the 5 ECG Electrode contact areas integrated into the patch Output Electrical signals collected in a central area for input to the Novii Pod. The patch is passive, but converts the electrophysiological signals on the body into electronic signals for the Novii Pod Encryption Microchip containing factory pre-set code (SHA_256 encryption) Weight 12g Dimensions 190mm x 155mm x 12mm (including clip) IP rating IP57 only when mated to the Novii Pod, otherwise IP20 Shelf Life 12 months (from Date of Manufacture) Latex & PVC Free Yes Packaging Individual foil pouches & transportation cards Operating Temperature +10°C to +30°C Storage Temperature +10°C to +30°C *Content and quantity can vary by country Novii Pod Part Number 107-PT-003 Operating Mode Real-Time/ Continuous Use Bluetooth Wireless Output Bluetooth v2.1 + EDR, Class 1.5, to Novii Interface Protocol Modified Series 50 Range 30m (line of sight) User Interface LED FHR Range: 60 -240 BPM Resolution: ¼ BPM, 4 times/ second, rolling 2 sec average Accuracy: Bland Altman vs AN24 predicate 7.08BPM rms [1] Range: 40 -240 BPM Resolution: ¼ BPM, 4 times/ second, rolling 2 sec average Accuracy: Bland Altman vs AN24 predicate 5.32BPM rms [2] Range: 0 – 500 microvolts Resolution: 0 – 255 levels representing 100% of full scale, 4 MHR UA times/ second, rolling 2 second average Accuracy: 97.99% percent agreement (interpretability) 86.05% Positive Percent Agreement (Sensitivity) Power Battery Rechargeable Lithium Polymer 3.7V, 750mAh 80% capacity after 475 charge cycles Battery Life Up to 11 hrs Battery Charging Contactless via the Novii Interface. Charge time for x2 fully discharged Pods – up to 2 hours Weight 40g Dimensions 45mm x 39mm x 20mm (including contact pins) IP rating IP57 only when mated to the Novii Patch, otherwise IP20 Accessories Novii Patch (107-PT-004) Operating Temperature +10°C to +30°C Storage Temperature +10°C to +30°C Type Type BF Equipment (applied part is the Novii patch, which connects to the pod via the spring contact pins at the bottom of the pod) Novii Interface Part Number 107-PT-001 Operating Mode Real-Time/ Continuous Use Data I/O Bluetooth Wireless Input Bluetooth v2.1 + EDR, Class 1.5, from Novii Interface Protocol Modified Series 50 Range 30m (line of sight) Output Real Time to fetal monitor via Novii Interface cables, comprising: User Interfaces Direct fetal ECG pulse (for FHR) MECG pulse (for MHR) Uterine Activity waveform (for UA) Capacitive Touch Screen LCD display Resolution: 800 x 400 (RGB 65K Colors) Viewing Area: 108mm x 65mm Touch Panel Durability: 1 Million (tap test) Alert Buzzer Charging Bays Frequency: 3.4kHz ± 0.5kHz 2x wireless charging bays for Novii Pods (with magnetic location) Charge Time for 2x fully discharged pods - up to 2 hours uses IrDA to facilitate automatic pairing with the Pod Power Supply Input 100 to 240V~, 50Hz to 60Hz, 400mA Output 18 W 5V DC, 2500mA Energy Efficiency VI USA pin out Part Number: 107_PT_002_US EU, UK, AU pin out Part Number: 107_PT_002 Dimensions 152mm x 137mm x 150mm Weight 688g IP rating Accessories Interface Connection Cables for GE Corometrics 174 & 259cx Series monitor: FHR (105-PT-102); MHR (105-PT-104) UA (105-PT-106). Power Supply: 107-PT-002_US Operating Temperature +10°C to +30°C Storage Temperature +10°C to +30°C Intended Use The Monica Novii Pod is an intrapartum maternal fetal The Novii Patch is an accessory to the Novii Pod that monitor that non invasively measures and displays fetal connects directly to the Novii Pod and contains the surface heart rate (FHR), uterine activity (UA) and maternal heart electrodes that attach to the abdomen. rate (MHR). The Novii Pod acquires and displays the FHR tracing from abdominal surface electrodes that pick up the fetal ECG (fECG) signal. Using the same surface electrodes, the Pod also acquires and displays the UA tracing from the uterine electromyography (EMG) signal and the MHR tracing from the maternal ECG signal (mECG). The Pod is indicated for use on women who are at term (>36 The Novii Interface is an accessory to the Novii Pod which provides a means of interfacing the wireless output of the Novii Pod to the transducer inputs of the Fetal monitor. The Novii Interface enables signals collected by the Novii Pod to be printed and displayed on the Fetal Monitor and sent on to a central network, if connected. completed weeks), in labor, with singleton pregnancies, The Novii Pod maternal fetal monitor and its accessories using surface electrodes on the maternal abdomen. are intended for use by healthcare professionals. Approvals & Key Certifications FDA Cleared CE Marked IEC 60601-1:2005 +A1: 2012 incl. Medical Electrical Equipment USA deviations Part 1: General requirements for basic safety and essential performance EN 60601-1-2:2015/IEC 60601-1-2:2014 (edition 4) Medical Electrical Equipment Part 1-2: General Requirements for basic safety and essential performance – Collateral standard: Electromagnetic compatibility – requirements and tests EN ISO14971: 2012 Medical Devices – Application of risk management to medical devices (ISO 14971:2007, Corrected version 2007-10-01) ANSI /AAMI EC12-2000-(R)2015 Disposable ECG electrodes IEC 62133:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications BS EN 10993 Biological evaluation of medical devices FCC CFR 47: Part 15 Subpart C & Part 18 FCC CFR 47 Part 15 Subpart C covering the FCC requirements for ANSI-IEC-60529 Specification for degrees of protection provided by enclosures (IP code) EN 62479:2010 Assessment of the compliance of low power electronic and electrical equipment. (SAR) EN 61000-3 parts 2 & 3 Limits: Emission limits, Immunity limits Intentional Radiators, Part 18 Medical Devices About Monica Healthcare With over 25 years of research, expert knowledge and collaborations with leading hospitals, Monica Healthcare has developed an advanced electrophysiological technology to produce fetal monitors that are beneficial for midwives, L&D nurses and expectant women. The patented technology is based on the acquisition of electro-physiological signals that can be passively detected by electrodes positioned on the maternal abdomen. From these signals a number of parameters, fetal heart rate, maternal heart rate, uterine activity and maternal movements can be extracted, in real time, and over an extended period of time. Monica Healthcare is part of the Maternal Infant Care solutions offered by GE Healthcare. Through GE Healthcare’s global network, the Novii Wireless Patch system will help to improve maternal and infant care worldwide. 0843 Part No: 107-TF-100-USrev7 © 2016 Monica Healthcare Ltd All rights reserved Monica Healthcare reserves the right to make changes to the features shown herein or discontinue the product described at any time without notice or obligation and will not be liable for any consequences resulting from the use of this document. Novii and Monica are registered trademarks of Monica Healthcare in the USA, EU, China and Japan. JB30822US(7) Part of GE Healthcare Monica Healthcare Limited Unit 8, Interchange 25 Business Park, Bostocks Lane, Nottingham, NG10 5QG, UK Tel: +44 115 949 6960 E-mail: novii.info@ge.com www.monicahealthcare.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2016:01:20 13:05:51Z Creator : Adobe InDesign CS6 (Macintosh) Modify Date : 2017:11:28 09:22:54Z Has XFA : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Metadata Date : 2017:11:28 09:22:54Z Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:d26913da-c295-487b-9ea5-46fef7f36107 Original Document ID : xmp.did:15097824082068118083E69CA802BA70 Document ID : xmp.id:BFA342D0282068118083C84472C6D8C6 Rendition Class : proof:pdf History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2016:01:20 13:05:51Z Derived From Instance ID : xmp.iid:BEA342D0282068118083C84472C6D8C6 Derived From Document ID : xmp.did:15097824082068118083E69CA802BA70 Derived From Original Document ID: xmp.did:15097824082068118083E69CA802BA70 Derived From Rendition Class : default Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 6EXIF Metadata provided by EXIF.tools