GE MDS DS-9810 Spread Spectrum Data Tranceiver User Manual

GE MDS LLC Spread Spectrum Data Tranceiver Users Manual

Users Manual

 Installation and Operation GuideInstallation & Operation Guide MDS 05-3301A01, Rev. CJULY 2004 900 MHz Spread SpectrumData Transceivers Microwave Data Systems Inc. MDS 9810
 QUICK START GUIDE Below are the basic steps for installing the transceiver. Detailed instructions are given in “INSTALLA-TION” on Page 14 of this guide. 1. Install and connect the antenna system to the radio • Use good quality, low-loss coaxial cable. Keep the feedline as short as possible.• Preset directional antennas in the direction of desired transmission. 2. Connect the data equipment to the radio’s INTERFACE connector • Connection to the radio must be made with a DB-25 Male connector. Connections for typical sys-tems are shown below. • Connect only the required pins. Do not use a straight-through RS-232 cable with all pins wired.• Verify the data equipment is configured as DTE. (By default, the radio is configured as DCE.) 3. Apply DC power to the radio • Observe proper polarity. The red wire is the positive lead; the black is negative. 4. Set the radio’s basic configuration with a Hand-Held Terminal (HHT) • Set the baud rate/data interface parameters as follows. Use the  BAUD xxxxx abc  command, where  xxxxx  equals the data speed and  abc  equals the communication parameters as follows: a  = Data bits (7 or 8) b  = Parity (N for None, O for Odd, E for Even c  = Stop bits (1 or 2)(Example:  BAUD 9600 8N1 )  NOTE: 7N1, 8E2 and 8O2 are invalid data parameters. 5. Verify proper operation by observing the LED display • Refer to Table 4 on Page 26 for a description of the status LEDs.• Refine directional antenna headings for best received signal strength using the  RSSI  command. • If difficulties are encountered, please refer to Table 14 on Page 56 for troubleshooting help.DB-25 DB-25232345206DSR DSR6TXDRXDGNDRTSCTSTXDRXDGND4CTS5RTSDB-9 DB-25DB-9 to DB-25 ExampleDB-25 to DB-25 Example114523325207RXDTXDDCDGNDDSRRTSRXDTXDDCDGNDAs required for application51876CTSDSRRTSCTS864577GND GND8 8DCD DCDAs required for applicationRTU(DTE)TRANSCEIVER(DCE)RTU(DTE)TRANSCEIVER(DCE)
 MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide i TABLE OF CONTENTS 1.0   ABOUT THIS MANUAL.........................................................................................................1 2.0   PRODUCT DESCRIPTION................................................................................................... 1 Transceiver Features........................................................................................................................2Model Configuration Codes .............................................................................................................22.1   Spread Spectrum Radios—How Are They Different? ....................................................................32.2   Typical Applications  .......................................................................................................................3Multiple Address Systems (MAS) ....................................................................................................3Simplex “Peer-to-Peer”.....................................................................................................................4Peer-to-Peer with Repeater Assistance ...........................................................................................4Point-to-Point System.......................................................................................................................5Tail-End Link (“MAS Extension”)......................................................................................................5Repeater System—Traditional .........................................................................................................6“Single-Radio” Repeater—Alternative Method.................................................................................62.3   Accessories  ...................................................................................................................................7 3.0   INSTALLATION PLANNING.................................................................................................. 7 3.1   General Requirements  ..................................................................................................................73.2   Site Selection  ................................................................................................................................8Terrain and Signal Strength .............................................................................................................9Conducting a Site Survey ................................................................................................................93.3   A Word About Radio Interference ................................................................................................103.4   Antenna & Feedline Selection  .....................................................................................................11Antennas........................................................................................................................................11Feedlines .......................................................................................................................................123.5   How Much Output Power Can be Used? .....................................................................................13Transmitter Power vs. Antenna System Gain.................................................................................13 4.0   INSTALLATION ................................................................................................................... 14 4.1   Transceiver Installation  ................................................................................................................154.2   Peer-to-Peer Systems  .................................................................................................................19Simplex Peer-to-Peer.....................................................................................................................19Peer-to-Peer with Repeater Assistance .........................................................................................204.3   Tail-End Links  ..............................................................................................................................21Interface Wiring..............................................................................................................................21Programming .................................................................................................................................224.4   Repeaters—Traditional Method ...................................................................................................22Antennas........................................................................................................................................23System Addresses.........................................................................................................................23Interface Wiring..............................................................................................................................23Diagnostic Limitations....................................................................................................................23
 ii MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C4.5   “Single-Radio” Repeater—Alternative Method  ............................................................................24Interface Wiring..............................................................................................................................24Software Programming (TDD Command)......................................................................................24Limitations of Single-Radio Repeaters...........................................................................................254.6   Using the Radio’s Sleep Mode  ....................................................................................................25Sleep Mode Example.....................................................................................................................25 5.0   OPERATION ....................................................................................................................... 26 5.1   Initial Start-up  ..............................................................................................................................265.2   Performance Optimization  ...........................................................................................................26Antenna Aiming..............................................................................................................................27Antenna SWR Check.....................................................................................................................27Data Buffer Setting.........................................................................................................................27Hoptime Setting .............................................................................................................................27Baud Rate Setting..........................................................................................................................28Radio Interference Checks.............................................................................................................28 6.0   PROGRAMMING................................................................................................................ 28 6.1   Hand-Held Terminal Connection & Start-up  ................................................................................286.2   Hand-Held Terminal Setup  ..........................................................................................................296.3   Keyboard Commands ..................................................................................................................30Entering Commands ......................................................................................................................30Error Messages..............................................................................................................................316.4   Detailed Command Descriptions .................................................................................................35ADDR [1...65000]...........................................................................................................................36AMASK [0000 0000–FFFF FFFF]..................................................................................................36ASENSE [HI/LO]............................................................................................................................36BAUD [xxxxx abc] ..........................................................................................................................36BUFF [ON, OFF]............................................................................................................................37CTS [0–255]...................................................................................................................................37CTSHOLD [0-6000]........................................................................................................................38DEVICE [DCE, CTS  KEY].............................................................................................................38DLINK [xxxxx] ................................................................................................................................39DMGAP [xx] ...................................................................................................................................39DTYPE [NODE/ROOT/GATE/PEER] .............................................................................................39HOPTIME [XSHORT, 16, 20, 25, 32, SHORT, NORMAL, LONG] .................................................40INIT ................................................................................................................................................41MODE [M, R, R-M].........................................................................................................................41OWM [xxxxx]..................................................................................................................................42OWN [xxxxx] ..................................................................................................................................42PWR [xx–30]..................................................................................................................................42RSSI...............................................................................................................................................42RTU [ON/OFF/0-80].......................................................................................................................43RX [xxxx]........................................................................................................................................43RXTOT [NONE, 0–1440]................................................................................................................43SEND [n, -n, +n].............................................................................................................................43SETUP...........................................................................................................................................44SHOW [PORT, DC, PWR]..............................................................................................................45SIMPLEX [ON, OFF]......................................................................................................................45
 MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide iiiSKIP [NONE, 1...8] ........................................................................................................................46SKIPSYNC [ON/OFF] ....................................................................................................................46SNR ...............................................................................................................................................46SREV .............................................................................................................................................47STAT...............................................................................................................................................47TDD [ON/OFF]...............................................................................................................................47TEMP.............................................................................................................................................48TX [xxxx] ........................................................................................................................................48UNIT [10000–65000]......................................................................................................................48ZONE DATA ...................................................................................................................................49ZONE CLEAR................................................................................................................................50 7.0   TROUBLESHOOTING ........................................................................................................ 50 7.1   LED Indicators .............................................................................................................................507.2   Alarm Codes ................................................................................................................................51Checking for Alarms—STAT command..........................................................................................51Major Alarms vs. Minor Alarms ......................................................................................................51Alarm Code Definitions ..................................................................................................................527.3   Performing Network-Wide Remote Diagnostics  ..........................................................................53DLINK [xxxxx] ................................................................................................................................55DTYPE [NODE/ROOT/GATE/PEER] .............................................................................................557.4   Troubleshooting Chart  .................................................................................................................56 8.0   TECHNICAL REFERENCE................................................................................................. 56 8.1   Technical Specifications ..............................................................................................................568.2   RSSI Checks with a Voltmeter .....................................................................................................588.3   Data Interface Connections (DB-25)  ...........................................................................................588.4   Bench Testing Setup ....................................................................................................................618.5   Using Radio Configuration Software  ...........................................................................................61Connecting a PC............................................................................................................................62Upgrading the Radio’s Software ....................................................................................................628.6   dBm-Watts-Volts Conversion Chart .............................................................................................63 9.0   GLOSSARY OF TERMS..................................................................................................... 63 Copyright Notice This Installation and Operation Guide and all software described herein are protected by  copy-right: 2004  Microwave Data Systems  Inc. All rights reserved.Microwave Data Systems reserves its right to correct any errors and omissions in this document.  Operational Safety Notice The radio equipment described in this guide emits radio frequency energy. Although the power level is low, the concentrated energy from a directional antenna may pose a health hazard. All antennas used with this transmitter, whether indoor or outdoor mounted, must be installed to pro-vide a separation distance of at least  23 cm  from all persons, and must not be co-located or oper-ating in conjunction with any other antenna or transmitter. In mobile applications (vehicle RFExposure
 iv MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C mounted) the above separation distance must be maintained at all times. More information on RF exposure is available on the Internet at  www.fcc.gov/oet/info/documents/bulletins . This manual is intended to guide a professional installer to install, operate and perform basic system mainte-nance on the described radio.  CSA/ US  Notice This product is available for use in Class I, Division 2, Groups A, B, C & D Hazardous Locations. Such locations are defined in Article 500 of the National Fire Protection Association publication NFPA 70, oth-erwise known as the National Electrical Code. The product has been recognized for use in hazardous locations by the Canadian Standards Association (CSA), which also issues the US mark of approval (CSA/ US ). The CSA Certification is in accordance with CSA STD C22.2 No. 213-M1987. The product has been evaluated in accordance with the following stan-dards:• CSA Std C22.2 No. 142-M1987 - Process Control Equipment• CSA Std C22.2 No. 213-M1987 - Non-Incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations• ANSI/UL Std No. 508 - Industrial Control Equipment• UL Std No. 1604 - Electrical Equipment for Use in Class I and II, Division 2; Class III Hazardous (Clas-sified) Locations ISO 9001 Registration Microwave Data Systems' adherence to this internationally accepted quality system standard pro-vides one of the strongest assurances of product and service quality available. MDS Quality Policy Statement We, the employees of Microwave Data Systems, are committed to achieving total customer satis-faction in everything we do. Total Customer Satisfaction in: • Conception, design, manufacture and marketing of our products.• Services and support we provide to our internal and external customers. Total Customer Satisfaction Achieved Through: • Processes that are well documented and minimize variations.• Partnering with suppliers who are committed to providing quality and service.• Measuring our performance against customer expectations and industry leaders.• Commitment to continuous improvement and employee involvement.
 MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide v FCC Notice, U.S.A. The transceiver complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.This device is specifically designed to be used under Section 15.247 of the FCC Rules and Regu-lations. Any unauthorized modification or changes to this device without the express approval of Microwave Data Systems may void the user’s authority to operate this device.Furthermore, this device is indented to be used only when installed in accordance with the instruc-tions outlined in this manual. Failure to comply with these instructions may also void the user’s authority to operate this device. Manual Revisions/Updates While every reasonable effort has been made to ensure the accuracy of this manual, product improvements may result in minor differences between the manual and the product shipped to you. If you have additional questions or need an exacts specification for a product, please contact our Customer Service Team using the information at the back of this guide. In addition, manual updates can often be found on the MDS Web site at www.microwavedata.com.
 vi MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C
 MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 1 1.0 ABOUT THIS MANUAL This guide presents installation and operating instructions for the MDS 9810 transceiver. Following installation, we suggest keeping this guide near the equipment for future reference. NOTE: Earlier versions of this manual also covered the MDS 24810(2.4 GHz) transceiver, which has been discontinued by MDS.An electronic version of the earlier manual is available for download at www.microwavedata.com. 2.0 PRODUCT DESCRIPTION The transceiver, shown in Figure 1, is a spread spectrum radio designed for license-free operation in the 900 MHz frequency band. Employing microprocessor control and Digital Signal Processing (DSP) tech-nology, the unit is highly reliable for long-distance communications, even in the presence of weak signals or interference.DSP technology also makes it possible to obtain information about radio operation and troubleshoot problems, without going to the remote radio site. Using the appropriate software at the master station, diagnostic data can be obtained on any DSP radio in the system, even while payload data is being transmitted. (See “Performing Network-Wide Remote Diagnostics” on Page 53.)The transceiver is housed in a compact and rugged die-cast aluminum case that need only be protected from direct exposure to the weather. It contains a single printed circuit board with all necessary components for radio operation. No jumper settings or adjustments are required to con-figure the radio for operation. Invisible place holder Figure 1. MDS 9810 TransceiverEXTERNAL INTERFACECONNECTOR(DB-25)DIAGNOSTICS CONNECTOR (RJ-11)13.8 VDC POWER CONNECTORANTENNA CONNECTOR(TYPE “N”)SERIAL NUMBERLABELLED INDICATORS (4)
 2 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C Transceiver Features Listed below are several key features of the transceiver. These are designed to ease the installation and configuration of the radio, while retaining the ability to make changes in the future.• 1,019 frequencies over 902–928 MHz, subdivided into eight frequency zones• Configurable operating zones to omit frequencies with constant interference• 65,000 available network addresses• Network-wide configuration from the master station; eliminates most trips to remote sites• Data transparency–ensures compatibility with virtually all asynchronous SCADA system RTUs• Peak-hold RSSI, averaged over eight hop cycles• Operation at up to 19200 bps continuous data flow;38400 bps non-continuous• Same hardware for all supported data rates:1200, 2400, 4800, 9600, 19200, 38400 bps asynchronous• Same hardware for master or remote configuration• Data latency typically less than 10 ms• Supports EIA-232 (formerly called RS-232) user interface• Low current consumption–30 mA or less average draw in “sleep” mode. Model Configuration Codes The radio model number is printed on the end of the radio enclosure, and provides key information about how the radio was configured when it left the factory. See Figure 2 for an explanation of the model number characters. Invisible place holder Figure 2. Transceiver Model Configuration Codes98PACKAGE1= Transceiver onlyOPERATIONX= Remote/MasterPOWER SETTING1= 10.5 - 30 Vdc*DIAGNOSTICS0= None1= Non-IntrusiveN= N/ASAFETY APPROVALN= N/AMOUNTING BRACKETSA= StandardB= None0XNAGENCY APPROVALF= FCC/ICU= FM/UL/CSA* Units shipped prior to Revision “U” (November 1999) may be configured for 25 Vdc maximum DC input.THIS INFORMATION IS SUBJECT TO CHANGE.DO NOT USE FOR PRODUCT ORDERING.
 MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 3 Invisible place holder 2.1 Spread Spectrum Radios—How Are They Different? The main difference between a traditional (licensed) radio system and the MDS 9810 transceiver is that these units “hop” from channel to channel many times per second using a specific hop pattern applied to all radios in the network. A distinct hopping pattern is provided for each of the 65,000 available network addresses, thereby minimizing the chance of interference with other spread spectrum systems. In the USA, and certain other countries, no license is required to install and operate this type of radio system. 2.2 Typical Applications Multiple Address Systems (MAS) This is the most common application of the transceiver. It consists of a central control station (master) and two or more associated remote units, as shown in Figure 3. An MAS network provides communications between a central host computer and remote terminal units (RTUs) or other data collection devices. The operation of the radio system is trans-parent to the computer equipment. When used in this application, the transceiver provides an excellent alternative to traditional (licensed) MAS radio systems. Invisible place holder Figure 3. Typical MAS NetworkRTURTURTURTURTUMASTER RADIO(MDS 9820 Shown)REMOTE RADIOREMOTE RADIOREMOTE RADIOREMOTE RADIOREMOTE RADIOHOST SYSTEM
 4 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C Simplex “Peer-to-Peer” Peer-to-peer communication is possible using the transceiver’s simplex mode. With this arrangement (Figure 4), two or more remote units can share information by direct communication with each other in addition to communicating with a central master radio. This is possible because the transmit and receive frequencies for each hop channel are the same at each radio when simplex mode is enabled. If adequate transmission paths exist, each radio can communicate with all other units in the net-work. Additional details for peer-to-peer systems are provided in Section 4.2 (Page 19). Invisible place holder Figure 4. Typical simplex “Peer-to-Peer” Network Peer-to-Peer with Repeater Assistance Peer-to-peer communication is also possible using this alternate arrangement (see Figure 5). It overcomes the range limitations of a sim-plex peer-to-peer system by using a repeater to re-transmit the signals of all stations in the network. The repeater consists of two radios—one pro-grammed as a remote using master frequencies ( MODE R-M  command), and the other programmed as a conventional master. Additional details for peer-to-peer systems are given in Section 4.2 (Page 19).RTU RTUPEER-TO-PEER PEER-TO-PEERRTURTUREMOTE RADIOMASTER RADIOHOST SYSTEMPEER-TO-PEERREMOTE RADIO REMOTE RADIOREMOTE RADIO
 MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 5 Invisible place holder Figure 5. Typical Peer-to-Peer Network with Repeater Assistance Point-to-Point System A point-to-point configuration (Figure 6) is a simple arrangement con-sisting of just two radios—a master and a remote. This provides a sim-plex or half-duplex communications link for the transfer of data between two locations. Invisible place holder Figure 6. Typical Point-to-Point Link Tail-End Link (“MAS Extension”) A tail-end link can be used to extend the range of a traditional (licensed) MAS system. This might be required if an outlying site is blocked from the MAS master station by a natural or man-made obstruction. In this arrangement, an MDS 9810 radio links the outlying remote site into the rest of a licensed MAS system by sending data from that site to an asso-ciated MDS 9810 installed at one of the licensed remote sites. (See Figure 7).As the data from the outlying site is received at the licensed remote site, it is transferred to the licensed radio (via a local cable connection) and is then transmitted to the MAS master station in the usual manner. Addi-tional details for tail-end links are given in Section 4.3 (Page 21).RTUREMOTEHOST COMPUTERRTURTUREPEATER STATIONPin 3 Pin 2* Special operating mode.  See Programming section of manual.REMOTEREMOTEREMOTEREMOTE-MASTER*MASTERREMOTE RADIORTUMASTER RADIOHOSTSYSTEM
 6 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C Invisible place holder Figure 7. Typical Tail-End Link Arrangement Repeater System —Traditional Although the range between MDS 9810 radios is typically 10 to15 miles over average terrain, it is possible to extend the range considerably by connecting two units together at one site in a “back-to-back” fashion to form a repeater, as shown in Figure 8. Additional details for repeater systems are given in Section 4.4 (Page 22). Invisible place holder Figure 8. Typical Repeater System Configuration “Single-Radio” Repeater —Alternative Method A repeater may also be established using a  single  MDS x810 Trans-ceiver. This type of repeater cannot operate in full-duplex mode as with the traditional repeater described above. However, if a loss in transmis-sion speed and efficiency can be tolerated, it may be a viable solution in some systems. POINT-TO-POINTSPREAD SPECTRUMLINKREMOTERADIOMASTERSTATIONMAS SYSTEM (LICENSED OR UNLICENSED) MDS 9810/9820 LINK TO AN OUTLYING SITEREPEATERRTUREMOTERADIONull-ModemCableRTURTUMDS 9810 / 9820MASTER  RADIOMDS 9810 / 9820REMOTE  RADIOREMOTERADIORTURTUREPEATER LINKNull-Modem CableRTUMASTERRADIOREMOTE RADIOREMOTE RADIOREMOTE RADIOREMOTE RADIOMASTERRADIOHOST COMPUTERPOINT-TO-POINT LINK
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 7A single-radio repeater works similar to the system shown in Figure 8, but consists of just one transceiver at the repeater site. It works by buff-ering (storing) incoming messages and retransmitting them a short time later. Accordingly, there will be a delay in transmissions through this type of repeater. Additional details for Single-Radio repeater s are given in Section 4.5 (Page 24).2.3 AccessoriesThe transceiver can be used with one or more of the accessories listed in Table 1. Contact the factory for ordering details.3.0 INSTALLATION PLANNINGThe installation of the radio is not difficult, but it does require some planning to ensure station reliability and efficiency. This section pro-vides tips for selecting an appropriate site, choosing an antenna system, and reducing the chance of harmful interference.3.1 General RequirementsThere are three main requirements for installing the radio—adequate and stable primary power, a good antenna system, and the correct inter-face between the transceiver and the data device.Table 1. Accessories  Accessory Description MDS P/NPower Supply Kit For powering the transceiver from an AC source. 01-3682A01Hand-HeldTerminal Kit(HHT)Terminal that plugs into the radio’s RJ-11 DIAG(NOSTICS) connector. Allows radio programming, diagnostics & control. Includes carrying case, cable set and manual.02-1501A01RTU Simulator Test unit that simulates data from a remote terminal unit. Comes with polling software that runs on a PC. Useful for testing radio operation.03-2512A01Radio Configuration SoftwareWindows-based software that allows radio programming and control using a PC. Includes on-line instructions. (See Section 8.5 (Page 61) for PC connection details.)03-3156A01Paging Filter Antenna system filter used to reduce RF interference from paging transmitters operating in the 905-915 MHz band.20-2822A01Paging Filter Antenna system filter used to reduce RF interference from paging transmitters operating in the 902-927 MHz band.20-22822A02EIA-232 to EIA-422ConverterExternal adapter that converts the radio’s DATA INTERFACE connector to EIA-422 compatible signaling. May be required for long cable runs (over 50 feet/15 meters). 03-2358A01
8 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CFigure 9 shows a typical remote station arrangement. At a remote sta-tion, a directional antenna is normally used, and a Remote Terminal Unit (RTU) or other telemetry equipment replaces the host computer nor-mally used in a master station.Invisible place holderFigure 9. Typical Remote Station Arrangement3.2 Site SelectionFor a successful installation, careful thought must be given to selecting proper sites for the master and remote stations. Suitable sites should pro-vide:• Protection from direct weather exposure• A source of adequate and stable primary power• Suitable entrances for antenna, interface or other required cabling• Antenna location that provides an unobstructed transmission path in the direction of the associated station(s)These requirements can be quickly determined in most cases. A possible exception is the last item—verifying that an unobstructed transmission path exists. Radio signals travel primarily by line-of-sight, and obstruc-tions between the sending and receiving stations will affect system per-formance. If you are not familiar with the effects of terrain and other obstructions on radio transmission, the discussion below will provide helpful background.13.8 VDCPOWER CABLE13.8 VDC POWER SUPPLY REMOTE TERMINAL UNIT ANTENNA SYSTEM(Directional Type Normally Used)LOW-LOSS FEEDLINEREMOTE RADIO
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 9Terrain and Signal StrengthWhile the 900 MHz band offers many advantages over VHF and lower UHF frequencies for data transmission, they are also more prone to signal attenuation from obstructions such as terrain, foliage or buildings in the transmission path.A line-of-sight transmission path between the master station and its associated remote site(s) is highly desirable and provides the most reli-able communications link. A line-of-sight path can often be achieved by mounting the station antenna on a tower or other elevated structure that raises it to a level sufficient to clear surrounding terrain and other obstructions.The importance of a clear transmission path relates closely to the dis-tance to be covered by the system. If the system is to cover only a limited geographic area, say up to 3 miles (4.8 km), then some obstructions in the transmission path can usually be tolerated with minimal impact. For longer range systems, any substantial obstruction in the transmission path could compromise the performance of the system, or block trans-mission entirely.Much depends on the minimum signal strength that can be tolerated in a given system. Although the exact figure will differ from one system to another, a Received Signal Strength Indication (RSSI) of –90 dBm or stronger will provide acceptable performance in many systems. While the equipment will work at lower signal strengths, this provides a “fade margin” to account for variations in signal strength which may occur from time-to-time. RSSI can be measured with a Hand-Held Terminal connected to the remote radio’s DIAG(NOSTICS) connector. (See Section 6.0, beginning on Page 28.)Conducting a Site SurveyIf you are in doubt about the suitability of the radio sites in your system, it is best to evaluate them before a permanent installation is begun. This can be done with an on-the-air test (preferred method); or indirectly, using path-study software.An on-the-air test is preferred because it allows you to see firsthand the factors involved at an installation site and to directly observe the quality of system operation. Even if a computer path study was conducted ear-lier, this test should be done to verify the predicted results.The test can be performed by first installing a radio and antenna at the proposed master station site and then visiting each remote site with a transceiver and a hand-held antenna. (An RTU simulator—MDS Part No. 03-2512A01—can be connected to each radio in the network to sim-ulate data during this test.)
10 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CWith the hand-held antenna positioned near the proposed mounting spot, a technician can check for synchronization with the master station (shown by a lit SYNC lamp on the front panel) and measure the reported RSSI value. If adequate signal strength cannot be obtained, it may be necessary to mount the station antennas higher, use higher gain antennas, or select a different site. To prepare the equipment for an on-the-air test, follow the general installation procedures given in this guide and become familiar with the operating instructions given in Sec-tion 5.0, beginning on Page 26.If time is short, and a site survey is impractical, a computer path study is a good alternative. Factors such as terrain, distance, transmitter power, receiver sensitivity, and other conditions are taken into account to predict the performance of a proposed system. Contact MDS for more information on path study services.3.3 A Word About Radio InterferenceThe transceiver shares frequency spectrums with other services and other Part 15 (unlicensed) devices in the USA. As such, near 100% error free communications may not be achieved in a given location, and some level of interference should be expected. However, the radio’s flexible design and hopping techniques should allow adequate performance as long as care is taken in choosing station location, configuration of radio parameters and software/protocol techniques.In general, keep the following points in mind when setting up your com-munications network:1. Systems installed in rural areas are least likely to encounter interference; those in suburban and urban environments are more likely to be affected by other devices operating in the license-free frequency band and by adjacent licensed services.2. If possible, use a directional antenna at remote sites. Although these antennas may be more costly than omnidirectional types, they con-fine the transmission and reception pattern to a comparatively nar-row lobe, which minimizes interference to (and from) stations located outside the pattern. (The use of a directional antenna may not be possible in a simplex peer-to-peer network, where all remotes are designed to communicate with one another.)3. If interference is suspected from a nearby licensed system (such as a paging transmitter), it may be helpful to use horizontal polarization of all antennas in the network. Because most other services use ver-tical polarization in this band, an additional 20 dB of attenuation to interference can be achieved by using horizontal polarization.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 114. Multiple MDS 9810 systems can co-exist in proximity to each other with only very minor interference as long as they are each assigned a unique network address. Each network address has a different hop pattern.5. If constant interference is present in a particular frequency zone, it may be necessary to “lock out” that zone from the radio’s hopping pattern. The radio includes built-in software to help users identify and remove blocked frequency zones from its hopping pattern. Refer to the discussion of ZONE DATA (Page 49) and SKIP (Page 46) com-mands for more information.6. If interference problems persist even after removing blocked zones, try reducing the length of data streams. Groups of short data streams have a better chance of getting through in the presence of interfer-ence than do long streams.7. The power output of all radios in a system should be set for the low-est level necessary for reliable communications. This lessens the chance of causing unnecessary interference to nearby systems.3.4 Antenna & Feedline SelectionAntennasThe equipment can be used with a number of antennas. The exact style used depends on the physical size and layout of a system. Contact your MDS representative for specific recommendations on antenna types and hardware sources.In general, an omnidirectional antenna (Figure 10) is used at the master station site in an MAS system. This provides equal coverage to all of the remote sites.NOTE: Antenna polarization is important. If the wrong polarization isused, a signal reduction of 20 dB or more will result. Mostsystems using a gain-type omnidirectional antenna at themaster station employ vertical polarization of the signal; there-fore, the remote antenna(s) must also be vertically polarized(elements oriented perpendicular to the horizon).When required, horizontally polarized omnidirectionalantennas are also available. Contact your MDS representativefor details.
12 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CInvisible place holderFigure 10. Typical Omnidirectional AntennaAt remote sites and point-to-point systems, a directional antenna, such as a Yagi is generally recommended to minimize interference to and from other users. Antennas are available from a number of manufac-turers.Invisible place holderFigure 11. Typical Yagi Antenna (mounted to mast)FeedlinesThe choice of feedline used with the antenna should be carefully consid-ered. Poor-quality coaxial cables should be avoided, as they will degrade system performance for both transmission and reception. The cable should be kept as short as possible to minimize signal loss.For cable runs of less than 20 feet (6 meters), or for short range trans-mission, an inexpensive type such as Type RG8A/U may be acceptable. Otherwise, we recommend using a low-loss cable type suited for 900 MHz, such as Heliax®.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 13Table 2 lists several types of feedlines and indicates the signal losses (in dB) that result when using various lengths of each cable at 900 MHz. The choice of cable will depend on the required length, cost consider-ations, and the amount of signal loss that can be tolerated. 3.5 How Much Output Power Can be Used?The transceiver is normally supplied from the factory set for a nominal +30 dBm (1 Watt) RF power output setting; this is the maximum trans-mitter output power allowed under FCC/IC rules. The power must be decreased from this level if the antenna system gain exceeds 6 dBm. The allowable level is dependent on the antenna gain, feedline loss, and the transmitter output power setting. Power considerations for various antenna systems are discussed below.NOTE: In some countries, the maximum allowable RF output may belimited to less than 1 watt (e.g., 100 mW /+20 dBm). Be sureto check for and comply with the requirements for your area.Transmitter Power vs. Antenna System GainTo determine the maximum allowable power setting of the radio, follow the steps below. It is imperative that professional system planning include cable loss or attenuators to ensure that the FCC/IC limit of 36 dBm EIRP is not exceeded under any circumstances.1. Determine the antenna system gain by subtracting the feedline loss (in dB) from the antenna gain (in dBi). For example, if the antenna gain is 9.5 dBi, and the feedline loss is 1.5 dB, the antenna system gain would be 8 dB. (If the antenna system gain is 6 dB or less, no power adjustment is required.)2. Subtract the antenna system gain from 36 dBm (the maximum allowable EIRP). The result indicates the maximum transmitter power (in dBm) allowed under the rules. In the example above, this is 28 dBm.Table 2. Length vs. Loss in Coaxial Cables at 900 MHz Cable Type 10 Feet(3.05 Meters) 50 Feet(15.24 Meters) 100 Feet(30.48 Meters) 500 Feet(152.4 Meters)RG-8A/U 0.85 dB 4.27 dB 8.54 dB 42.70 dB1/2 inch HELIAX 0.23 dB 1.15 dB 2.29 dB 11.45 dB7/8 inch HELIAX 0.13 dB 0.64 dB 1.28 dB 6.40 dB1 1/4 inch HELIAX 0.10 dB 0.48 dB 0.95 dB 4.75 dB1 5/8 inch HELIAX 0.08 dB 0.40 dB 0.80 dB 4.00 dBThe maximum EIRP allowed under FCC/IC rules is +36 dBm. Follow this section carefully to ensure compliance.IMPORTANT
14 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C3. If the maximum transmitter power allowed is less than 30 dBm, use the PWR command (described on Page 42) to set the power accord-ingly.For convenience, Table 3 lists several antenna system gains and shows the maximum allowable power setting of the radio. Note that a gain of 6 dB or less entitles you to operate the radio at full power output—30 dBm (1 watt).* Many antenna manufacturers rate antenna gain in dBd in their literature. To convert to dBi, add 2.15 dB.† Feedline loss varies by cable type and length. To determine the loss for common lengths of feedline, see Table 2 on Page 13.4.0 INSTALLATIONFigure 12 shows a typical transceiver product shipment, along with an optional Hand-Held Terminal (HHT). Check the contents against the packing list secured to the outside of the shipping box. Accessories and spare parts kits, if any, are wrapped separately. Inspect all items for signs of damage and save all packing materials for possible re-shipment.Table 3. Antenna System Gain vs. Power Output Setting (USA)Antenna System Gain(Antenna Gain in dBi*minus Feedline Loss in dB†)Maximum PowerSetting(in dBm) EIRP(in dBi6 (or less) 30 36729368283610 26 36
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 15Invisible place holderFigure 12. Typical Transceiver ShipmentBelow are the basic steps for installing the transceiver. In most cases, these steps alone will be sufficient to complete the installation. Should further information be required, contact the factory at the number given on the inside back cover of this manual.If you are installing a peer-to-peer, tail-end link or repeater system, you should also review Sections 4.2 (Page 19) and 4.3 (Page 21) for impor-tant details on antennas, cabling and software settings.NOTE: It is recommended that the master station be installed first. Inthis way, it will be possible to quickly check the operation ofeach associated remote station as it is placed on the air.4.1 Transceiver Installation1. Mount the transceiver to a stable surface using the brackets supplied with the radio. (Fasteners/anchors are not supplied.) Figure 13 shows the dimensions of the transceiver case and its mounting bracket. If possible, choose a mounting location that provides easy access to the connectors on the end of the radio and an unobstructed view of the LED status indicators.INSTALLATION &OPERATION GUIDE13.8 VDCPOWER CABLEHAND-HELDTERMINAL(OPTIONAL)AF1BF2CF3DF4EF5FGH1I2J3KLM4N5O6PQR7S8T9UVWX0Y.ZCTRL ESCBKSP SPACE ENTERSHIFT/(*)–#+,=TRANSCEIVER
16 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CInvisible place holderFigure 13. Transceiver Mounting DimensionsThe screws holding the brackets to the radio are 5⁄16  inch (8 mm). If replacement screws are used for any reason, they must not exceed this length to avoid damage to the radio’s PC board.2. Install the antenna and antenna feedline for the station. Antennas should be mounted in the clear and in accordance with the manufac-turer’s instructions. Additional information on antennas and feedlines is contained in Section 3.4 (Page 11).NOTE: Strong fields near the antenna can interfere with the operationof the low level RTU circuits and change the reported valuesof the data being monitored. For this reason, the antennashould be mounted at least 10 feet (>3 meters) from the radio,RTU, sensors and other components of the system.3. Connect the data equipment to the transceiver’s DATA INTERFACE connector. Use only the required pins for the application—Do not use a fully pinned (25 conductor) cable. Typical applications require the use of Pin 2 (transmit data—TXD), Pin 3 (received data—RXD) 1.75"4.44 CMAlternatePosition2.25"57 mm2.0"50 mm6.63"168 mm8.5"216 mm5.625"143 mm7.25"184 mm2.75"70 mmCAUTIONPOSSIBLEEQUIPMENTDAMAGE
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 17and Pin 7 (signal ground). Figure 14 shows a detailed view of the DATA INTERFACE connector.If hardware flow control is desired, Pin 4 (request to send—RTS) and Pin 5 (Clear-to-Send—CTS) are also required. A detailed chart of pin functions is provided in Table 15 on Page 59.Invisible place holderFigure 14. Transceiver Interface Connector Pins(As viewed from outside the radio)NOTE: The data cabling between the transceiver and the connecteddevice should be kept as short as possible. Cable runs over 50feet (15 meters) may require the use of EIA-422 signaling.Consult the factory for details.4. Measure and install the primary power for the transceiver. It must be within 10.5–30 Vdc* and be capable of furnishing up to 500 mA. Be sure to observe proper polarity. The red wire on the power cable is the positive lead; the black is negative.* Transceivers shipped prior to Revision “U” (November 1999) may be configured for 25 Vdc maximum DC input voltage.NOTE: The radio is designed for use only in negative ground systems.Additionally, the chassis must be bonded to an Earth ground,either directly, through its mounting bracket, or via the antennasystem ground (coaxial shield). The radio may be damaged ifthe chassis is not properly grounded per this recommendation.Radios damaged in this way will not be covered underwarranty.The power supply used with the transceiver should be equipped with overload protection (NEC Class 2 rating), to protect against a short circuit between its output terminals and the transceiver power connector.5. Set the radio’s configuration using a Hand-Held Terminal (HHT). Review Section 6.0, PROGRAMMING (beginning on Page 28), if you are unfamiliar with connecting and using the HHT.UnusedRadio Inhibit (Sleep)Unused13121110987654321Receiver Unsquelched SensorUnusedData Carrier Detect (DCD)Signal Ground*Data Set Ready (DSR)Clear-to-Send Output (CTS)Request-to-Send Input (RTS)Received Data (RXD)*Transmitted Data (TXD)*Protective Ground252423222120191817161514Alarm  OutputAnalog Input PinDiagnostic Channel EnableRSSI Voltage9.9 Vdc Regulated OutputUnregulated DC Input/OutputDigital Output PinUnusedUnusedUnusedPinDescription PinNo. PinNo. PinDescriptionUnused Future use— do not connect* Required in most installations
18 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CThe three essential settings for the transceiver are:Mode—Master or RemoteNetwork Address—a unique number from 1–65000Data Interface Parameters—bps, data bits, parity, stop bitsa. Connect an HHT to the DIAG(NOSTICS) connector (see Figure 15). After the HHT beeps, press   to display the ready “>” prompt.b. Set the Mode—Determine whether the transceiver will be used as a master or remote, and program it accordingly using the MODE M or MODE R command (Page 41). (MODE M = Master, MODE R = Remote.) Press  . The HHT will display PRO-GRAMMED OK.NOTE: Transceivers are normally shipped from the factorypre-configured as remotes. A master must be specificallyprogrammed using the MODE M command.Invisible place holderFigure 15. HHT Connected to Transceiverc. Program the network address—Type ADDR (Page 36) followed by  ,  , and then the desired address number (1–65000). Press .  All radios in a given system must be programmed with the same network address. After programming the address, PROGRAMMED OK will be displayed.NOTE: It is strongly recommended that the last four digits of themaster radio’s serial number be used as the network address.In this way, it is unlikely that two systems will have the sameaddress.ENTERENTERANTENNA13.8 VDC+ –ZCTRLU+–K*F/AF1V,Q#)G(BF2SHIFT ESCW=R7M4H1CF3BKSPX0S8N5I2DF4SPACEYT9O63EF5ENTERJLPSPACE SHIFTENTER
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 19d. Set the data interface parameters to match the connected data device—The default setting is 4800 baud, 8 data bits, no parity, 1 stop bit. If your data equipment requires a different setting, use the BAUD xxxxx abc command (Page 36), where xxxxx equals the baud rate (1200, 2400, 4800, 9600, 19200, or 38400 bps) and abc indicates the control bits as follows:a = Data bits (7 or 8)b = Parity (N for None, O for Odd, E for Even)c = Stop bits (1 or 2)Using this scheme, a sample entry for the BAUD xxxxx abc com-mand would look like this: BAUD 4800 8N1 (A similar example using a five-character baud rate would appear as follows: BAUD 19200 8N1)Press  . After setting the data parameters, PROGRAMMED OK will be displayed.NOTE: 7N1, 8O2, and 8E2 are invalid communication settings and arenot supported by the transceiver.e. Record the Mode, Network Address, and Baud Rate settings on a label and affix it to the transceiver cover.6. Repeat the above steps for each transceiver in the network.This completes the basic installation of the transceiver. Section 5.1, Ini-tial Start-up (beginning on Page 26), contains steps for evaluating radio performance.4.2 Peer-to-Peer SystemsPeer-to-peer systems allow remote radios to communicate with each other as well as with the master station. The paragraphs below describe two types of peer-to-peer systems—simplex and repeater assisted.Simplex Peer-to-PeerA simplex peer-to-peer system is one in which all radios use the same transmit and receive frequencies. This is also known as single-frequency operation. A simplex arrangement is the simplest configuration for peer-to-peer systems, but it usually has limited transmission range because of the need for all stations to use omnidirectional antennas. (If range is a concern, see “Peer-to-Peer with Repeater Assistance” on page 20.)With a simplex peer-to-peer system, there are three key items to remember:Programming To program a system for simplex operation, the master radio must be set to SIMPLEX ON (Page 45). This setting is automatically ENTER
20 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. Capplied to all remote radios as soon as they become synchronized with the master radio.Antennas Omnidirectional antennas are normally required at all stations in a simplex system. The transmission range may be significantly reduced as compared with stations using directional antennas, so it is especially important that sites be chosen to allow sufficient signal strength between all units. A discussion of site selection is provided in Section 3.2.Data “Collision” Avoidance One drawback with peer-to-peer systems is the risk of data “colli-sions” that can occur through self-interference. This problem can be alleviated with data protocols (such as Harris DNP3) which use Carrier Sense Multiple Access (CSMA) to detect a busy channel. In these systems, Pin 10 (Receiver Unsquelched-RUS) on the trans-ceiver should be connected to the RTU’s Data Carrier Detect (DCD) pin.Peer-to-Peer with Repeater AssistanceA shortcoming of a simplex peer-to-peer network is that communication range is often reduced because of the need for all stations to use omni-directional antennas. An alternative peer-to-peer network can be estab-lished using a repeater station to re-transmit the signals of all stations in the network. (See Figure 16.) Because directional antennas (aimed at the repeater site) can be used at all remote sites, the communication range of the system is greatly increased. Like a simplex peer-to-peer system, each remote station can “hear” the transmissions of the others so that data collisions can be avoided.Invisible place holderFigure 16. Peer-to-Peer Network with Repeater AssistanceHere are some specific requirements for peer-to-peer systems with repeater assistance:Repeater Setup The repeater station in a peer-to peer network consists of two co-located transceivers—one programmed as a remote using master MASTERREMOTE-MASTERRTUREMOTEREMOTEHOSTCOMPUTERRTUREMOTERTUREMOTEREPEASTATIONTERPin 3 Pin 2
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 21frequencies (MODE R-M command, Page 41), and the other pro-grammed as a master (MODE M command).Interface Wiring Pin 2 (TXD) of the master radio must be connected to Pin 3 (RXD) of the other radio (the one programmed as MODE R-M) using a local interface cable. This allows the signals received by the MODE R-M radio to be re-transmitted by the master. The signal ground leads (Pin 7) must also be connected to each other.Invisible place holderFigure 17. Data Interface Cable Wiringfor Peer-to-Peer Systems with Repeater AssistanceAntennas Two omnidirectional antennas are required at peer-to-peer repeater stations—one for each radio. It is important to minimize coupling between these antennas. The necessary isolation can be achieved by vertical separation. In this arrangement, one antenna is mounted directly over the other, separated by at least 10 feet (3.2 Meters). This takes advantage of the minimal radiation exhibited by verti-cally polarized antennas directly above and below one another.Full-Duplex Configuration The paragraphs above discuss the requirements for a basic Repeater Assisted Peer-to-Peer system. If a full-duplex system is required (with the SCADA host computer located at the repeater), additional considerations apply. If you are constructing this type of system, contact the factory and request a copy of Application Bulletin 97002. The bulletin can also be found at www.microwavedata.com.4.3 Tail-End LinksA tail-end link is established by connecting the radio “back-to-back” with another radio such as a licensed MDS 2300/4300 series transceiver. This can be used to link an outlying remote site into the rest of an MAS network. Here are some specific requirements for tail-end link systems:Interface WiringThe connection between the two radios in a tail-end link system must be made as shown in Figure 18.DB-25 DB-25Master(Mode M327237Remote Master(Mode R-M)RXDTXDGNDTXDRXDGND
22 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CInvisible place holderFigure 18. Data Interface Cable Wiring for Tail-End LinksProgrammingIn a tail-end link system, the radio’s device behavior must be set to DEVICE CTS KEY (Page 38) using the HHT. This allows one radio to control the keying of another. Also, the CTS delay time must be set (using the CTS xxx command, Page 37) to the time required for the other transceiver to key up. This time is typically 10 ms for MDS 2000/4000 series transceivers.4.4 Repeaters—Traditional MethodTwo MDS 9810 radios (or another MDS spread spectrum radio) may be connected “back-to-back” using a null-modem cable to form a repeater station. This is sometimes required in a network that includes a distant remote station that would otherwise be unable to communicate with the master station due to distance or terrain.A repeater works by re-transmitting data from the outlying remote site to the master station and vice versa. It introduces a small amount of end-to-end transmission delay, but this is not a problem in most systems.The geographic location of a repeater station is especially important. A site must be chosen that allows good communication with both the master and the outlying remote site. This is often on top of a hill, or other elevated terrain from which both sites can be “seen” by the repeater sta-tion antennas. A detailed discussion on the effects of terrain is given in Section 3.2, Site Selection (beginning on Page 8).The following paragraphs contain specific requirements for repeater systems.DB-25 DB-25MDS 2000/4000 Series XCVR(or device requiring keyline)237327MDS Spread Spectrum Remote XCVR (DEVICE CTS KEY)TXDRXDGNDRXDTXDGND54CTS RTSKeylineDCE DCE
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 23AntennasTwo antennas are required at repeater stations—one for each radio. Measures must be taken to minimize the chance of interference between these antennas. One effective technique for limiting interference is to employ vertical separation. In this arrangement, one antenna is mounted directly over the other, separated by at least 10 feet (3 Meters). This takes advantage of the minimal radiation exhibited by most antennas directly above and below their driven elements.Another interference reduction technique is to cross-polarize the repeater antennas. If one antenna is mounted in the vertical plane, and the other in the horizontal plane, an additional 20 dB of attenuation can be achieved. (Remember that the corresponding stations must use the same antenna orientation when cross-polarization is used.)System AddressesThe two radios that are wired together at the repeater site must have dif-ferent system addresses. To set or view the system address, see “ADDR [1...65000]” on page 36.Interface WiringA null-modem cable (Figure 19) is required between the DATA INTER-FACE connectors of the two radios forming a repeater station. This allows them to freely exchange data even though they are both config-ured as DCE devices.Invisible place holderFigure 19. Data Interface Cable Wiring for Null-Modem Cable(used for traditional repeater)Diagnostic LimitationsAs of the date of publication, over-the-air diagnostics is not fully sup-ported in repeater systems. Diagnostic data from these systems may be unavailable or unreliable. This is particularly true if a repeater radio is configured as the “root” in a diagnostics scheme (See “Performing Net-work-Wide Remote Diagnostics” on Page 53.) Better success might be achieved by picking a standard remote to use as the root.DB-25 DB-25Spread Spectrum Master(DCE)237327Spread Spectrum Remote(DCE)TXDRXDGNDRXDTXDGND
24 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C4.5 “Single-Radio” Repeater—Alternative MethodA single MDS x810 transceiver may be used to form a repeater station to extend the range of a system. The general repeater principles dis-cussed in Section 4.4 apply to single-radio repeaters—why repeaters are used, geographic site considerations, etc. However, there are some important differences in single-radio repeater systems:• Only one transceiver is used at the repeater site.• The transceiver’s TXD & RXD pins must be tied together (DB-25).• There may be considerable delay through the repeater, because the radio buffers (stores) incoming data and retransmits it a short time later.The paragraphs that follow contain specific requirements for single-radio repeater systems.Interface WiringA single-radio repeater is formed by connecting TXD (Pin 2) and RXD (Pin 3) on the DATA INTERFACE connector together as shown in Figure 20.Invisible place holderFigure 20. Data Interface Cable Wiring for Single-Radio RepeaterSoftware Programming (TDD Command)As with other repeater systems, the network must be configured for TDD operation by programming the master radio with TDD ON. This places the DATA INTERFACE port in time division duplex (sometimes called “simulated full-duplex”) mode.Although a single radio can never actually transmit and receive RF data at the same time, the TDD ON command enables the radio to simulate full-duplex at the data port, by designating alternate channel hops as transmit or receive hops, and buffering data when transmission is not permitted.DB-25DATA INTERFACECONNECTOR23TXDRXDPins 2 & 3Connected Togetherfor Single-Radio Repeater
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 25Limitations of Single-Radio RepeatersDiagnostics As of the date of publication, over-the-air diagnostics is not fully sup-ported in repeater systems. Diagnostic data from these systems may be unavailable or unreliable. This is particularly true if a repeater radio is configured as the “root” in a diagnostics scheme (See “Performing Net-work-Wide Remote Diagnostics” on Page 53.) Better success might be achieved by picking a standard remote to use as the root.Data Throughput Delay When TDD is set to ON, there will be a significant delay in data throughput and an increase in latency (see Glossary of Terms). In gen-eral, the data throughput will be cut in half, and worst case latency will increased by two hoptimes.4.6 Using the Radio’s Sleep ModeIn some installations, such as at solar-powered sites, it may be necessary to keep the transceiver’s power consumption to an absolute minimum. This can be accomplished using Sleep Mode. In this mode, power con-sumption is reduced to less than 30 milliamperes.Sleep Mode can be enabled under RTU control by asserting a ground (or EIA-232 low) on Pin 12 of the radio’s DATA INTERFACE connector. The radio stays in Sleep Mode until the low is removed, and all normal func-tions are suspended. As a status indication, the radio’s PWR LED flashes once every four seconds to indicate that it is in Sleep Mode.The radio can be “woken up” by your RTU every minute or so to verify synchronization with the master station. When Pin 12 is opened (or an EIA-232 high is asserted), the radio will be ready to receive data within 75 milliseconds.It is important to note that power consumption will increase signifi-cantly as communication from the master station degrades. This is because the radio will spend a greater period of time “awake,” looking for synchronization messages from the master radio.Sleep Mode ExampleThe following example describes Sleep Mode implementation in a typ-ical system. Using this information, you should be able to configure a system that meets your own particular needs.Suppose you need communications to each remote site only once per hour. Program the RTU to raise an EIA-232 line once each hour (DTR for example) and wait for a poll and response before lower-ing it again. Connect this line to Pin 12 of the radio’s DATA INTER-FACE connector. This will allow each RTU to be polled once per hour, with a significant savings in power consumption.
26 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C5.0 OPERATION5.1 Initial Start-upIn-service operation of the transceiver is completely automatic. Once the unit has been properly installed and configured, operator actions are limited to observing the LED status indicators for proper operation.If all parameters are correctly set, operation of the radio can be started by following these steps:1. Apply primary power to the radio.2. Observe the transceiver LED status panel (Figure 21) for the proper indications. Table 4 provides a complete explanation of the LED functions.In a normally operating system, the following LED indications will be seen within 16 seconds of start-up:•PWR lamp lit continuously•SYNC lamp lit continuously• Remote radio(s) transmitting data (TXD) and receiving data (RXD) with the master station Invisible place holderFigure 21. LED Status Indicators5.2 Performance OptimizationAfter the basic operation of the radio has been checked, you may wish to optimize its performance using some of the suggestions given here. The effectiveness of these techniques will vary with the design of your system and the format of the data being sent.PWR SYNC TXD RXDTable 4. LED Status Indicators LED Name DescriptionPWR • Continuous—Power is applied to the radio; no problems detected.• Flashing 5 times per second—Fault indication.See Section 7.0, TROUBLESHOOTING (beginning on Page 50).• Flashing once every 4 seconds—radio is in Sleep mode.SYNC Lights continuously to indicate the radio is receiving/sending synchronization frames. Within 16 seconds of power-up, this LED should be lit continuously.TXD Indicates EIA-232 space (logic high) signal input to the DB-25 connector.RXD Indicates EIA-232 space (logic high) signal output from the DB-25 connector.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 27Complete instructions for using the software commands referenced herein are provided in Section 6.0, PROGRAMMING (beginning on Page 28).Antenna AimingFor optimum performance of directional antennas, they must be accu-rately aimed in the direction of desired transmission. The easiest way to do this is to point the antenna in the approximate direction, then use the remote radio’s built-in Received Signal Strength Indication (RSSI) fea-ture to further refine the heading for maximum received signal strength.RSSI can be read by connecting an HHT to the remote radio’s RJ-11 DIAG(NOSTICS) jack and entering the RSSI command. Instructions on connecting and using an HHT are given in Section 6.0, PROGRAM-MING (beginning on Page 28).In an MAS system, RSSI readings are only meaningful when initiated from a remote station. This is because the master station typically receives signals from several remote sites, and the RSSI would be con-tinually changing as the master receives from each remote in turn.Antenna SWR CheckIt is necessary to briefly key the transmitter for this check by placing the radio in the SETUP mode (Page 44) and using the KEY command on the HHT. (To unkey the radio, enter DKEY; to disable the setup mode and return the radio to normal operation, enter Q or QUIT.)The SWR of the antenna system should be checked before the radio is put into regular service. For accurate readings, a wattmeter suited for 1000 MHz is required. One unit meeting this criteria is the Bird Model 43™ directional wattmeter with an 5J element installed.The reflected power should be less than 10% of the forward power (≈2:1 SWR). Higher readings usually indicate problems with the antenna, feedline or coaxial connectors.Data Buffer SettingThe default setting for the data buffer is ON to accommodate virtually any data format. However, if the system can operate satisfactorily with the buffer OFF, we recommend doing so using the BUFF OFF command (Page 37). This allows the radio to operate with the lowest possible latency and improves channel efficiency.Hoptime SettingThe default hop time setting is HOPTIME NORMAL. If message sizes typi-cally exceed 256 bytes, channel efficiency can be improved by setting this parameter to HOPTIME LONG.
28 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CA detailed explanation of the HOPTIME command, and a table listing the available selections and the channel efficiency associated with each, can be found on Page 40.Baud Rate SettingThe default baud rate setting is 4800 bps to accommodate most systems. If your system will support a higher data rate, you should increase the radio’s transmission speed using the BAUD xxxxx abc command (Page 37). It should be set to the highest speed that can be sent by the data equipment in the system. (The transceiver supports 1200 to 38400 bps)Radio Interference ChecksThe ZONE DATA command (Page 49) can be used to check for interfer-ence in the radio’s eight frequency zones. If interference is found in one or more of these zones, the SKIP command (Page 46) can be used to omit them from the hop pattern. You should also review Section 3.3, A Word About Radio Interference (beginning on Page 10), when dealing with interference problems.6.0 PROGRAMMINGThere are no manual adjustments on the transceiver. Programming and control is performed remotely, using one of these methods:• MDS Hand-Held Terminal (P/N 02-1501A01)• MDS Radio Configuration Software (P/N 03-3156A01)• MDS Network Management SoftwareThis manual describes control of the radio using the Hand-Held Ter-minal (HHT). Instructions for using the other methods are contained in their respective user manuals or on-line documentation.6.1 Hand-Held Terminal Connection & Start-upThis section gives basic information for connecting and using the MDS Hand-Held Terminal for control of the radio. For more information about the terminal, see the instructions supplied with each HHT kit.The steps below assume that the HHT has been configured for use with the transceiver (80 character screen display). If the HHT was previously used with a different model transceiver, or if its default settings have been changed, refer to Section 6.2 for setup details.1. Connect the HHT’s coiled cord to the DIAG(NOSTICS) (RJ-11) jack on the radio as shown in Figure 22. This automatically places the radio into the control and programming mode. As an alternative, the DATA INTERFACE (DB-25) connector may be
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 29used for programming instead of the DIAG(NOSTICS) jack. With this arrangement, Pin 23 of the HHT cable must be grounded to enable the diagnostic channel. (See Table 15 on Page 59.)Invisible place holderFigure 22. Hand-Held Terminal Connected to the Transceiver2. When the HHT is connected, it runs through a brief self-check, end-ing with a beep. After the beep, press   to receive the ready “>” prompt.6.2 Hand-Held Terminal SetupThe following is a set of instructions for re-initializing an HHT for use with the transceiver. These steps may be required if the HHT was previ-ously used with a different radio, or if the HHT default settings have been inadvertently altered.1. Plug the HHT into the DIAG(NOSTICS) connector. Enable the setup mode by pressing the  ,   and   keys in sequence. The display shown in Figure 23 will appear.ANTENNA13.8 VDC+ –ZCTRLU+–K*F/AF1V,Q#)G(BF2SHIFT ESCW=R7M4H1CF3BKSPX0S8N5I2DF4SPACEYT9O63EF5ENTERJLPENTERSHIFTCTRLSPACE
30 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CInvisible place holderFigure 23. HHT setup display2. The first of 15 menu items will be displayed. Settings can be reviewed by pressing the NEXT function (  key). Parameter set-tings can be changed by pressing the ROLL function (  key).3. Set up the HHT as listed in Table 5.4. Exit the HHT setup mode by pressing   for Exit, or by pressing the  (Roll) key after the final menu item has been reviewed.6.3 Keyboard CommandsTable 6 is a reference chart of software commands for the transceiver. See Section 6.4 for detailed command descriptions.Entering CommandsThe proper procedure for entering commands is to type the command, followed by an   keystroke. For programming commands, the command is followed by   and the appropriate information or values, then  .ZEATable 5. HHT Operational Settings  Parameter Setting Parameter SettingRe-init HT NO Scroll On 33rdBaud Rate= 1200 Cursor ONComm bits= 8,1,n CRLF for CR OFFParity Error OFF Self Test SLOWKey Repeat OFF Key Beep ONEcho OFF Screen Size 80Shift Keys  YES Menu Mode LONGCtl Chars PROCSCAENTERSPACEENTER
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 31Here are some additional points to remember when using the HHT:• Use the   key to access numbers; press again to return let-ters.• Flashing square cursor ( ) denotes letter mode.• Flashing superscript rectangular cursor ( ) denotes number mode.• Use   key to edit information or commands being typed into the terminal.Error MessagesBelow are some HHT error messages you may encounter and their prob-able causes:•UNKNOWN COMMAND—Command was not recognized.•INCORRECT ENTRY—Command format or its arguments invalid.•COMMAND FAILED—Command was unable to complete success-fully. Possible software problem.•NOT PROGRAMMED—Software was unable to program the EEPROM or the requested display item was not programmed.•TEXT TOO LONG—Response to OWN or OWM command when too many characters have been entered.•NOT AVAILABLE—The entered command or parameter was valid, but it referred to a currently unavailable choice.•PASSWORD INVALID—The entered password was invalid, and was not accepted.•ACCESS DENIED—Command is invalid for current password level.•EPROM FAILURE—The INIT command cannot write to the radio’s EEPROM.SHIFTESC/BKSP
32 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CTable 6. Command Summary  COMMAND  DESCRIPTION NETWORKCONFIGURATIONThese programming commandscan only be set at the master radio.BUFF [ON, OFF]                          Details Page 37 ON = Seamless data, OFF = Fast byte through-put.HOPTIME [XSHORT, 16, 20, 25, 32, SHORT, NORMAL, LONG]                          Details Page 40Select hop time—XSHORT, 16 ms, 20 ms, 25 ms, 32 ms, SHORT, NORMAL, LONGSEND [n, -n, +n]                          Details Page 43Sets/displays re-send count for data packets. Useful in areas with heavy radio interference.SIMPLEX [ON, OFF]                          Details Page 45 Program simplex/half-duplex selection.ON = simplex, OFF = half-duplexSKIP [NONE, 1...8]                          Details Page 46 Select combination of frequency operating zones to avoid.SKIPSYNC [ON/OFF]                          Details Page 46 May be used to suppress transmission of SYNC messages in skipped zones. (See also SKIP command). Default setting is OFF.TDD [ON/OFF]                          Details Page 47 Sets or displays time-division multiplex status of DATA INTERFACE connector. (Sometimes referred to as “simulated full-duplex” mode.)NETWORK-WIDEDIAGNOSTICSCONFIGURATIONDLINK [xxxxx]                          Details Page 39 Set baud rate of diagnostics linkDTYPE [NODE/ROOT/GATE/PEER]                          Details Page 39Set radio’s operational characteristics for net-work-wide diagnosticsUNIT [10000–65000]                          Details Page 48 Program unit address. Used to set a unique address for network-wide diagnostics.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 33SET/PROGRAM COMMANDSADDR [1...65000]                          Details Page 36 Program network addressAMASK [0000 0000–FFFF FFFF]                          Details Page 36Sets alarm response. Default is FFFF FFFF. ASENSE [HI/LO]                          Details Page 36 Changes the sense of the alarm output. Default sense is HI. BAUD [xxxxx abc]                          Details Page 36 Set data communication parametersCTS [0–255]                          Details Page 37 Program CTS delay in milliseconds.(A value of 0 returns CTS immediately)CTSHOLD [0-6000]                          Details Page 38 Set/display “hold time” that CTS remains present following last character transmission from DD-25 port.DEVICE [DCE, CTS   KEY]                          Details Page 38 Set device behavior; DCE (normal) or CTS Key (Repeater)INIT                          Details Page 41 Initialize parameters to factory default valuesMODE [M, R, R-M]                          Details Page 41 Program operating mode, where M = Master,R = Remote, R-M = Remote-Master (Remote radio programmed to operate on Master fre-quencies)OWM [xxxxx]                          Details Page 42 Program owner’s message(30 characters maximum)OWN [xxxxx]                          Details Page 42 Program owner’s name(30 characters maximum)PWR [xx–30]                          Details Page 42 Program forward power output in dBm.RTU [ON/OFF/0-80]                          Details Page 43 Re-enables or disables the radio’s internal RTU simulator and sets the RTU address.RXTOT [NONE, 0–1440]                          Details Page 43 Specifies max. duration (in minutes) to wait before issuing a time-out alarm. Default is OFF. SEND [n, -n, +n]                          Details Page 43Sets/displays re-send count for data packets. Useful in areas with heavy radio interference.TDD [ON/OFF]                          Details Page 47 Sets or displays time-division multiplex status of DATA INTERFACE connector. (Sometimes referred to as “simulated full-duplex” mode.)UNIT [10000–65000]                          Details Page 48 Program unit address. Used to set a unique address for network-wide diagnostics.ZONE DATA                          Details Page 49 Show zone data statistics. Press “Q” to quitZONE CLEAR                          Details Page 50 Reset zone data statisticsTable 6. Command Summary (Continued)COMMAND  DESCRIPTION
34 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CDISPLAY OPERATING STATUSADDR [1...65000]                          Details Page 36 Network address (1-65000)AMASK [0000 0000–FFFF FFFF]                          Details Page 36Sets alarm mask (response). Default is FFFF FFFF.ASENSE [HI/LO]                          Details Page 36 Changes the sense of the alarm output. Default sense is HI.BAUD [xxxxx abc]                          Details Page 36 Display data communication parameters. Example: BAUD 9600 8N1BUFF [ON, OFF]                          Details Page 37 Data buffering mode: ON = seamless dataOFF = fast byte throughputCTS [0–255]                          Details Page 37 CTS delay in ms (0-255 ms)DUMP Show all settings. Use with PC-based Radio Configuration software (P/N 03-3156A01).DEVICE [DCE, CTS   KEY]                          Details Page 38 Device behavior (DCE, or CTS KEY)HOPTIME [XSHORT, 16, 20, 25, 32, SHORT, NORMAL, LONG]                          Details Page 40Show hop time in milliseconds (ms).HREV Hardware revision levelMODE [M, R, R-M]                          Details Page 41 Show operating mode: M = Master, R = Remote, R-M = Remote-Master (remote oper. on master freqs.)OWM Owner’s message or site nameOWN Owner’s name or system namePWR [xx–30]                          Details Page 42 Forward power output setting in dBmRSSI                          Details Page 42 Received signal strength in dBm (continuously updated). Not available at master radio unless SETUP is enabled.RXTOT [NONE, 0–1440]                          Details Page 43 Specifies amount of time (in seconds) to wait before issuing a time-out alarm. Default is NONE. SEND [n, -n, +n]                          Details Page 43Sets/displays re-send count for data packets. Useful in areas with heavy radio interference.SER Serial number of radioSHOW [PORT, DC, PWR]                          Details Page 45 Show active port, DC voltage or measured RF power (dBm)SIMPLEX [ON, OFF]                          Details Page 45 Simplex/half-duplex selectionON = Simplex, OFF = half-duplexSKIP [NONE, 1...8]                          Details Page 46 Skip a frequency operating zoneSKIPSYNC [ON/OFF]                          Details Page 46 When ON, suppresses transmission of SYNC messages in skipped zones. Default setting is OFF.Display parameters continued...Table 6. Command Summary (Continued)COMMAND  DESCRIPTION
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 356.4 Detailed Command DescriptionsThe essential commands for most applications are Network Address (ADDR), Mode, (MODE) and Baud Rate (BAUD). However, proper use of the additional commands allows you to tailor the transceiver for a spe-cific use, or to conduct basic diagnostics on the radio. This section gives more detailed information for many of the user commands listed in Table 6.Most of the commands below can be used in two ways. First, you can type only the command name (for example, ADDR) to view the currently programmed data. Second, you can set or change the existing data by typing the command, followed by a space, and then the desired entry (for example, ADDR 1234). In the list below, allowable programming variables, if any, are shown in brackets [  ] following the command name.DISPLAY OPERATING STATUS(CONTINUED)SNR                          Details Page 46 Signal-to-noise ratio. Expressed in dB.SREV                          Details Page 47Display transceiver firmware revision levelSTAT                          Details Page 47 Show current alarm statusTDD [ON/OFF]                          Details Page 47 Sets or displays time-division multiplex status of DATA INTERFACE connector. (Sometimes referred to as “simulated full-duplex” mode.)TEMP                          Details Page 48 Transceiver’s internal temperature (°C)UNIT [10000–65000]                          Details Page 48 Show programmed unit address for net-work-wide diagnosticsZONE DATA                          Details Page 49 Show zone data statistics (see text for details). Press “Q” to quit.DIAGNOSTIC/TESTKEY Enables the transmitter. (Radio must be in Setup mode.)DKEY Disables the transmitter. (Radio must be in Setup mode.)DMGAP [xx]                          Details Page 39 Sets the amount of time to wait after the receipt of a character before interpreting the next received character as the start of a new message.TX [xxxx]                          Details Page 48 Set/display transmit test frequency. (Radio must be in Setup mode.)RX [xxxx]                          Details Page 43 Set/display receive test frequency. (Radio must be in Setup mode.)SETUP                          Details Page 44 Enables Setup mode. Times out after 15 min-utes. Press “Q” to quit.Table 6. Command Summary (Continued)COMMAND  DESCRIPTION
36 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CADDR [1...65000]This command sets or displays the radio’s network address. The net-work address can range from 1 to 65000.Network address must be programmed at the time of installation and must be common across each radio in a given network. Radios are typi-cally shipped with the network address unprogrammed. This causes the address to display as NONE. This leaves the system in an invalid state and prevents operation.NOTE: It is recommended that the last four digits of the master radio’sserial number be used for the network address (or chassis serialnumber if the radio is installed in a P-20 redundant chassis).AMASK [0000 0000–FFFF FFFF]This command sets the alarm bits that cause the alarm output signal to be triggered. The PWR LED will still flash for all alarms, but the alarm output signal will only be activated for those alarms that have the corre-sponding mask bit set. The hex value for the mask aligns directly with the hex value for the ALARM command. The default is FFFF FFFF. Through proper use of the AMASK command, it is possible to tailor the alarm response of the radio. Contact the factory for more information on configuring the alarm mask.ASENSE [HI/LO]This command is used to set or display the sense of the alarm output at Pin 25 of the DATA INTERFACE connector. The default for transceivers is active HI.BAUD [xxxxx abc]This command sets or displays the communication attributes for the DATA INTERFACE port. The command has no effect on the RJ-11 DIAG(NOSTICS) port.The first parameter (xxxxx) is baud rate. Baud rate is specified in bits-per-second and must be one of the following speeds: 1200, 2400, 4800, 9600, 19200, or 38400. In the worst case, the radio will always accept a minimum of 500 data bytes in a single continuous data trans-mission. At baud rates of 4800 bps or less, the radio can support unlim-ited continuous data transmission at any hop rate. If hop time is set to NORMAL or LONG, baud rates of up to 19200 bps with continuous unlim-ited data transmission are possible. (See HOPTIME command.)The second parameter of the BAUD command (abc) is a 3-character block indicating how the data is encoded. The following is a breakdown of each character’s meaning:
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 37a = Data bits (7 or 8)b = Parity (N for None, O for Odd, E for Even)c = Stop bits (1 or 2)The factory default setting is 4800 baud, 8 data bits, no parity, 1 stop bit (Example: 4800 8N1).NOTE: 7N1, 8O2, and 8E2 are invalid communication settings and arenot supported by the transceiver.BUFF [ON, OFF]This command sets or displays the received data handling mode of the radio. The command parameter is either ON or OFF. (The default is ON.) The setting of this parameter affects the timing of received data sent out the DATA INTERFACE connector. Data transmitted over the air by the radio is unaffected by the BUFF setting.If data buffering is set to OFF, the radio will operate with the lowest pos-sible average latency. Data bytes are sent out the DATA INTERFACE port as soon as an incoming RF data frame is disassembled. Average and typ-ical latency will both be below 10 ms, but idle character gaps may be introduced into the outgoing data flow.If data buffering is ON, the radio will operate in a seamless mode. That is, data bytes will be sent over the air as quickly as possible, but the receiver will buffer the data until enough bytes have arrived to cover worst case gaps in transmission. The delay introduced by data buffering may range from 25 to 50 ms, but the radio will not create any gaps in the output data stream. This mode of operation is required for protocols such as MODBUS™ that do not allow gaps in their data transmission.Note that seamless mode (BUFF ON) is intended only for applications where the transmitter’s baud rate is greater than or equal to the receiver’s baud rate. Enforcement of this rule is left up to the user.Changes to the BUFF setting may only be made at the master radio. This is because the master radio broadcasts the buffer setting for the entire network. At remote radios, the buffer setting may be read when the radio is in synchronization with the master, but it may not be changed.CTS [0–255]The CTS (clear-to-send) command sets or displays the timer value asso-ciated with the CTS line response. The command parameter ranges from 0 to 255 milliseconds.
38 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CFor DCE operation, the timer specifies how long to wait after the RTS line goes high before asserting the CTS line. A timer value of zero means that the CTS line will always be asserted (unless the radio is attempting to throttle back data as part of normal flow control opera-tion).For CTS Key operation (see the DEVICE command), the timer specifies how long to wait after asserting the CTS line before sending data out the DATA INTERFACE port. A timer value of zero means that data will be sent out the data port without imposing a key-up delay. (Other delays may be in effect from other radio operating parameters.)CTSHOLD [0-6000]Used in DEVICE CTS KEY mode, this command sets the amount of time in milliseconds that CTS remains present following transmission of the last character out the RXD pin of the DATA INTERFACE port. This “hold time” can be used to prevent squelch tail data corruption when inter-working with other radios.The CTSHOLD setting can range from 0 to 6000 (i.e., 6 seconds). The default value is 0, which means that CTS will drop immediately after the last character is transmitted. If the command is entered when the radio is in DEVICE DCE mode, the response CTSHOLD N/A will be displayed.DEVICE [DCE, CTS  KEY]The DEVICE command sets or displays the device behavior of the radio. The command parameter is either DCE or CTS KEY.The default selection is DCE. In this mode, CTS will go high following RTS, subject to the CTS programmable delay time. Keying is stimulated by the input of characters at the data port. Hardware flow control is implemented by dropping the CTS line if data arrives faster than it can be transmitted.If CTS KEY is selected, the radio is assumed to be controlling another radio, such as in a repeater system. The RTS line is ignored and the CTS line is used as a keyline control for the other radio. CTS is asserted immediately after the receipt of RF data, but data will not be sent out the DATA INTERFACE port until after the CTS programmable delay time has expired. (This gives the other radio time to key.)Following transmission of the last byte of data, CTS will remain asserted for the duration specified by the CTSHOLD command. CTSHOLD should be set sufficiently high.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 39DLINK [xxxxx]DLINK followed by the baud rate sets the baud rate (bps) of the diagnos-tics link. The following DLINK baud rates selections are allowed:• 1200• 2400• 4800• 9600• 19200 (default setting)Example: DLINK 4800 sets the RJ-11 DIAG port to operate at 4800 bps. The default is DLINK 19200 and DLINK ON.NOTE: The same baud rate must be entered into the appropriatefield(s) of any Network Management Software, if used.DMGAP [xx]The DMGAP command sets the amount of time in milliseconds to wait after the receipt of a character before interpreting the next received char-acter as the start of a new message. When data port baud rates are slow, the gap between characters within a poll may be so long that the radio interprets the next character as the start of a new poll. When diagnostics is being performed using passive messaging (see Performing Net-work-Wide Remote Diagnostics on page 53), this command may be used to change this behavior.DTYPE [NODE/ROOT/GATE/PEER]The DTYPE command specifies the radio’s operational characteristics for network-wide diagnostics. There are four possible types of nodes in a network-wide diagnostics system.The common types are: •NODE–The most common setting, and the default. This is the basic system radio device-type. Typically, the radio network is comprised of nodes and one root. Intrusive diagnostics can orig-inate from any node. However, non-intrusive diagnostics can only be conducted from the root node.•ROOT–Always one, and only one, per network. The root is the focal point of network-wide diagnostics information. Intrusive diagnostics can originate from any radio, including the root. However, the root is the only radio through which non-intrusive diagnostics can be conducted.The default radio device-type is NODE. Less used are:•GATE•PEER
40 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CThese node types are needed for repeater sub-networks and simplex sub-networks where simplex frequencies are used. See the Net-work-Wide Diagnostics System Handbook (05-3467A01) for an expla-nation of these node types.HOPTIME [XSHORT, 16, 20, 25, 32, SHORT, NORMAL, LONG]The HOPTIME command sets or displays the hop time setting. The com-mand is one of eight keywords whose parameters and related efficien-cies are shown in Table 7.Although the default setting is HOPTIME NORMAL, transmission effi-ciency can usually be improved by using HOPTIME LONG when message sizes typically exceed 256 bytes. This is because there will be less fre-quent channel hops when using this setting, contributing to a smoother flow of transmitted data.Normally, HOPTIME NORMAL and LONG are the only settings required. Other hoptimes can be used to customize performance based on SEND count settings and payload data poll length.The only time shorter settings (SHORT through XSHORT) should be con-sidered is when the message size is very small and strong interference of a persistent nature is occurring on many frequencies. In these cases, a shorter hop time may improve the chances of a message getting through—but at the cost of reduced channel efficiency.Changes to the HOPTIME setting may only be made at the master radio. (This is because the master radio establishes the hop time setting for the entire network.) At remote radios, the hop time setting may be read when the radio is in synchronization with the master, but it may not be changed.Table 7. Hoptime ParametersHop Time KeywordTime per HopMax. Bytesper Hop ChannelEfficiencyXSHORT 10 ms 9 32.1%16 16 ms 21 46.7%20 20 ms 30 53.6%25 25 ms 39 55.7%32 32 ms 57 63.3%SHORT 40 ms 72 64.3%NORMAL 80 ms 162 72.0%LONG 160 ms 336 74.5%
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 41INITThe INIT command is used to reset the radio’s operating parameters to the factory defaults. This may be helpful when trying to resolve configura-tion problems that may have resulted from the entry of one or more improper command settings. If you are unsure of which command set-ting may have caused the problem, this command allows you to get back to a known working state.Use of the INIT command causes the changes shown in Table 8 to be applied.MODE [M, R, R-M]The MODE command sets or displays the operating mode of the radio. A master radio is designated by an M; a remote is designated by an R.Table 8. Factory Default ValuesProduced by INIT Command  Default Setting CorrespondingCommandFor all radiosDevice operation DCE DEVICE DCERF output power 30 dBm (1 watt) PWR 30CTS delay 0(CTS is continuously asserted)CTS 0DATA INTERFACE port 4800 baud8 data bitsno parity1 stop bitBAUD 4800 8N1Remote radiosTransmittertest frequency Per factory default TX xxxReceivertest frequency Per factory default RX xxxMaster radiosTransmittertest frequency Per factory default TX xxxReceivertest frequency Per factory default RX xxxSkipped frequencies None (radio will hop across all 1019 frequencies)SKIP NONEHop time Normal (80 ms per hop) HOPTIME NORMALSimplex/duplexoperation Half-duplex SIMPLEX OFFBuffer mode Seamless data mode enabled BUFF ON
42 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CR-M indicates that the transceiver has been programmed to the special remote-master mode (remote radio operating on master frequencies) This is used in repeater-assisted peer-to-peer systems; see Section 2.2, Typical Applications (beginning on Page 3) for details. The R-M mode denotes a remote radio operating on master frequencies. In all other respects, a remote-master behaves the same as a normal remote.All units default to remotes; other modes must be specifically pro-grammed with the MODE command.OWM [xxxxx]The OWM command sets or displays an optional owner’s message, such as the system name. The entry can contain up to 30 characters.OWN [xxxxx]The OWN command sets or displays an optional owner’s name, such as the site name. The entry can contain up to 30 characters.PWR [xx–30]This command displays or sets the desired RF forward output power set-ting of the radio. The PWR command parameter is specified in dBm and can range from 20 to 30 dBm in 1 dBm steps. The default setting is 30 dBm (1 watt). To read the actual (measured) power output of the radio, use the SHOW PWR command.In the USA and Canada, maximum allowable power is governed by limits on Effective Isotropic Radiated Power output (EIRP). The EIRP limit of +36 dBm means that any user with a net antenna gain greater than 6 dBi must decrease the PWR setting accordingly. Section 3.5, How Much Output Power Can be Used? (beginning on Page 13) contains a detailed discussion of this topic.RSSIThis command displays the radio’s Received Signal Strength Indication in dBm (decibels relative to 1 mW). The output can range from –50 dBm to –110 dBm. Command availability and results depend on the mode of operation (master or remote). The closer to 0 dBm, the stronger the signal, thus a reading of –70 dBm is stronger than –80 dBm.For a remote radio, under normal operation, RSSI is based on the average signal strength of the SYNC message received in each of the eight frequency zones. (RSSI is sampled each time a SYNC message is received—every 1.6 seconds.) When using the RSSI reading to align a directional antenna, it is important to make changes slowly so that the RSSI reading will provide meaningful results. It will take several sec-onds to indicate a change in signal level. The radio stays in RSSI mode until   is pressed.ENTER
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 43For a master radio, under normal operation, entering the RSSI command causes the response NOT AVAILABLE to be returned. This is because a master is normally receiving signals from several remote stations and an RSSI reading would be continually changing. The only exception is when the SETUP command has been asserted. This disables hopping and allows reading a “raw” RSSI signal level in real time from a master or remote radio.NOTE: RSSI Readings are not accurate for incoming signals strongerthan –50 dBm.)RTU [ON/OFF/0-80]This command re-enables or disables the radio’s internal RTU simu-lator, which runs with MDS’ proprietary polling programs (poll.exe and rsim.exe). The internal RTU simulator is available whenever a radio has diagnostics enabled. This command also sets the RTU address that the radio will respond to.The internal RTU can be used for testing system payload data or pseudo bit error rate (BER) testing. It can be helpful in isolating a problem to either the external RTU or the radio.RX [xxxx]This command sets or displays the test receive frequency used in place of hopping whenever the radio is in Setup mode. The test receive fre-quency can be reprogrammed to any value between 927.975 MHz and 902.025 MHz, inclusive. The factory default settings are listed below and have been selected to be non-intrusive to normal operation.RXTOT [NONE, 0–1440]This command sets or displays the amount of time (in minutes) to wait for the next received data packet before issuing a receiver time-out alarm. The default is NONE.SEND [n, -n, +n]The SEND command selects or displays the number of times that a radio will re-transmit data. This command is associated with “robust” or “bul-letproof” operation of the radio and is intended for use in areas with heavy radio interference.Default Receive FrequenciesMaster Remote927.975 MHz 902.025 MHz
44 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CWhen the SEND command is issued without parameters, the cumulative retransmission count is shown. A value of 1 represents the default selec-tion, meaning “normal, non-robust operation.” Values greater than 1 successively improve the chance of successful data delivery in spec-trally harsh environments. (Note that the SEND count for a remote radio is only viewable when the remote is synchronized with its master sta-tion.)There are two formats for entering the SEND command. One format (SEND n) can be used only at the master station, and selects the base transmission count for the entire network. The other format (SEND +n or –n) can be used at any radio in the network, and provides a means to cus-tomize the transmission count locally at each radio, as a delta (amount of change) from the base. For both formats, n represents number between 1 and 10; for the “delta” format a value of zero is also permitted. The net transmission count for a particular radio is determined by adding the local “delta” (+n or –n) to the base transmission count for the network. The net transmission count is automatically bounded to the range 1..10, irrespective of the delta. The combination of the two formats provides a means to highly cus-tomize the retransmission behavior of network.Higher retransmission counts come at the cost of increased latency and reduced data throughput. With BUFF ON, the radio maintains seamless operation based on timing derived from the network SEND value. The use of any tailored SEND values (e.g. SEND +/-x) within the system may disrupt seamless operation. This is because the increased latency makes seamless mode impractical. Table 2 lists the maximum cumulative SEND count for continuous operation, at some typical data rates.SETUPThis command sets up the transceiver for checking antenna SWR or transmitter power with external measuring equipment. Do not use this mode during normal operation.Table 9. Baud Rate vs. Maximum SEND CountBAUD RATE(BPS)XSHORT(max. send count)16 ms(max. send count)20 ms(max. send count)25 ms(max. send count)32 ms(max. send count)SHORT(max. send count)NORMAL(max. send count)LONG(max. send count)1200 3 8 10 10 10 10 10 102400 N/A 4 5 5 5 7 8 84800 N/A 2 2 2 2 3 4 49600 N/A N/A N/A N/A N/A N/A 2 2
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 45When the SETUP command is entered, the HHT prompt changes to SETUP>, and:• Hopping is disabled.• Synthesizer frequencies are reset to the test frequencies speci-fied by the TX and RX commands.• The radio can be keyed using the KEY command. DKEY is used to unkey the radio. (If the radio is left in a keyed state it is auto-matically unkeyed after several minutes.)• The RSSI is sampled in a raw, continuous fashion regardless of whether the unit is a master or a remote.Entering Q or QUIT returns the system to normal operation.A timer keeps the Setup mode from accidentally leaving the system dis-abled. After 10 minutes the system behaves as if Q or QUIT had been entered, returning to normal operation.SHOW [PORT, DC, PWR]The SHOW command displays three types of information based on the command variables. These are:•PORT—Displays which connector port (RJ-11 or DB-25) is cur-rently active for diagnostics and control.•DC—Displays DC input/output voltages.•PWR—Displays the actual (measured) RF power output in dBm. Unlike the PWR command, this command shows the actual level being measured, not the programmed RF power setting.SIMPLEX [ON, OFF]The SIMPLEX command sets or displays the radio’s mode of operation (simplex or half-duplex).By default, the system operates in half-duplex mode (SIMPLEX OFF). In this mode, the transmit frequency of the master is the receive frequency of the remote (and vice-versa). The transceiver uses a transmit/receive frequency split of ±1.6 MHz. The offset varies such that both frequen-cies will always fit within the same zone. (A zone is a 3.2 MHz sub-band—see the ZONE DATA command.)When simplex mode is selected (SIMPLEX ON), the master and remotes always transmit and receive on the same frequency. This setting is required for peer-to-peer simplex networks where remotes must be able to communicate with other remotes. A slight increase in end-to-end delay will occur when using this mode.This command is “read-only” at remote radios. (Remotes must be syn-chronized with the master radio to read the simplex status.)
46 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CSKIP [NONE, 1...8]This command sets or displays which, if any, of the eight 3.2 MHz (128 frequency) zones will be skipped from the radio’s hopping sequence. Skipping zones is one way of dealing with constant interference on one or more frequencies. See Section 3.3 (Page 10) for more information on dealing with interference.Figure 24 shows the frequency range covered by each zone. The com-mand parameter is either the keyword NONE or an undelimited string of up to seven digits where each digit 1...8 represents a corresponding zone to skip. (For zone parameter input, the digits can appear in any order and can be optionally separated by a blank space.) The SKIP command is read-only at remote radios. (Remotes must be synchronized with the master radio to read the skip status.)Figure 24. Frequency Zones for MDS 9810 TransceiverSKIPSYNC [ON/OFF]Selectively suppresses transmission of SYNC messages in skipped zones (see SKIP command above). With SKIPSYNC set to ON, the trans-ceiver will not transmit SYNC messages in skipped frequency zones.This command is only available to transceivers that are set to be a master (MODE M). The default setting for this command is OFF.NOTE: Using SYNCSKIP when many zones are skipped will signifi-cantly lengthen the time it takes a remote to achieve synchro-nization with the master. (This will also manifest itself as veryslow RSSI reading response).SNRThis command displays the signal-to-noise ratio of the received signal expressed in dB. As used in this guide, the definition of signal-to-noise is based upon the signal level following equalization, for valid frames only. (A valid frame is defined as containing no more than one bit error, and belonging to a frame addressed for the receiving radio.) SNR is updated and latched for each valid frame received. A filter in the DSP tempers the effect of any sudden changes in the value.ZONE 1902.200to905.375ZONE 2905.400to908.575ZONE 3908.600to911.775ZONE 4911.800to914.975ZONE 5915.000to918.175ZONE 6918.200to921.375ZONE 7921.400to924.575ZONE 8924.600to927.775
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 47SNR output ranges from 10 dB to 33 dB. A value of 10 dB represents little or no signal. A value of 24 dB represents a very strong signal. For remote radios, a value of 0 is reserved to mean “no signal”; it is dis-played whenever a remote is not in synchronization with the master sta-tion.When the SNR command is used, it causes the DIAG(NOSTIC) port to enter an update mode, and it will provide an updated signal-to-noise ratio every 1.6 seconds. It stays in this mode until the   key is pressed.SREVThis command displays the software version currently loaded into the transceiver.A display of 06-3111A01, 3.5.1 is an example of the software version iden-tifier.STATThis command is used to check alarm status. If no alarms exist, the mes-sage NO ALARMS PRESENT appears at the top of the HHT display.If an alarm does exist, a two-digit event code (00–31) is displayed and the event is identified as a “major” or “minor” alarm. A brief description of the event is also given.If more than one alarm exists, the word MORE appears at the bottom of the screen and additional alarms are viewed by pressing the   key. Detailed descriptions of the alarm codes are provided in Table 12 on Page 52.TDD [ON/OFF]The TDD command selects or displays whether or not the DATA INTER-FACE port is operating in time division duplex (sometimes called “sim-ulated full-duplex”) mode. This command is “read-only” at remote radios.The x810 Transceiver is physically a half-duplex device. The radio can never actually transmit and receive RF data at the same time. However, TDD mode enables the radio to simulate full-duplex at the data port, by designating alternate hops as transmit or receive hops, and buffering (storing) data when transmission is not permitted. Default operation is TDD OFF.ENTERENTER
48 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CNote that when TDD is enabled (TDD ON), there is a significant impact on both data throughput and latency. Data throughput is roughly cut in half. Worst case data latency is increased by two hoptimes. The effect in seamless mode (BUFF ON) is even more pronounced, as shown in Table 10.TEMPThis command displays the internal temperature of the transceiver in degrees Celsius. (Note that the radio is specified to operate in an envi-ronment between –30 C° and +60 C°). This internal reading may be higher than the outside temperature by several degrees.TX [xxxx]This command sets or displays the test transmit frequency used in place of hopping whenever the radio is in Setup mode. The test transmit fre-quency can be reprogrammed to any value between 902.025 MHz and 927.975 MHz, inclusive. The factory default settings are listed below and have been selected to be non-intrusive to normal system operation.UNIT [10000–65000]This command sets the unit addressing for network-wide diagnostics. The unit address is factory programmed to the last four digits of the serial number. If re-programmed in the field, the entry must consist of five digits between 10000 and 65000.Table 10. Hoptime Setting vs. Delay (BUFF ON—”Seamless Mode”)HOP TIME MINIMUM DELAY MAXIMUM DELAYXSHORT 33 ms 66 msec16 39 ms 78 ms20 43 ms 86 ms25 48 ms 96 ms32 55 ms 110 msSHORT 63 ms 126 msecNORMAL 103 ms 206 msecLONG 183 ms 366 msecDefault Transmit Frequencies Master Remote902.025 MHz 927.975 MHz
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 49ZONE DATAThe transceiver divides its frequency operating spectrum into eight con-tiguous 3.2 MHz zones. (These are the same zones referenced by the SKIP command described earlier.) Data frame statistics are maintained for each zone to indicate the transmission quality through the network. This information is useful for identifying zones where significant inter-ference exists.Zone quality information can be accessed using the ZONE DATA com-mand on a connected HHT. For each zone (1–8), it shows you the number of data frames sent, the number received, and the number received with errors. If an excessive number of errors are seen in one or more frequency zones, it may indicate interference, and you should con-sider “skipping” those zones using the SKIP command.The ZONE DATA command displays its information on four lines as shown in Figure 25. If the display seems to “roll off” the screen, verify that your HHT is set for an 80 character screen size. See Section 6.2, Hand-Held Terminal Setup (beginning on Page 29).Invisible place holderFigure 25. HHT Display for ZONE DATA CommandIf ZONE DATA alone is entered, the information for Zone 1 is displayed first. Successive zones can be viewed by pressing the ENTER key, or by entering the zone number of your choice (1...8) at the NEXT ZONE?> prompt.It is also possible to go directly to a specific zone by entering ZONE DATA [1...8], where the number entered equals the desired zone. Data for the specified zone is displayed and then control returns to the command prompt.Entering Q or QUIT causes the program to exit and return to the command prompt.TOTAL SENTTOTAL RECEIVEDTOTAL REC'D WITH ERRORSZONE #DATA FRAME STATISTICS
50 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CA variation on the ZONE DATA command is ZONE DATA! This causes data to be retrieved from all zones. Data is sequentially displayed for each of the 8 zones and then control returns to the command prompt.(Note: If a frequency zone has been skipped, statistics will still be gath-ered for that zone when ZONE DATA is invoked at a remote site, but the numbers will accumulate very slowly since the only data being passed in a skipped zone is the radio’s synchronization signal. When invoked at a master, no polls will be received from a skipped zone.)ZONE CLEARThe ZONE CLEAR command clears the zone data for all zones, resetting the count to 0. (Zone data is also cleared automatically upon reboot, or upon saturation of a zone data counter.)7.0 TROUBLESHOOTINGSuccessful troubleshooting of an MDS transceiver system is not diffi-cult, but requires a logical approach. It is best to begin troubleshooting at the master station, as the rest of the system depends on the master for polling instructions and synchronization data. If the master station has problems, the operation of the entire network will be affected.When communication problems are found, it is good practice to begin by checking the simple things. All radios in the network must meet these basic requirements:• Adequate and stable primary power• An efficient and properly aligned antenna system• Secure connections (RF, data & power)• Proper programming of the radio’s operating parameters, espe-cially Mode selection (MODE), Network Address (ADDR), and interface Baud Rate (BAUD)• The correct interface between the radio and the connected data equipment (proper cable wiring, data format and timing).7.1 LED IndicatorsThe LED status indicators are an important troubleshooting tool and should be checked whenever a problem is suspected. Table 11 describes the function of each status LED.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 517.2 Alarm CodesWhen an alarm condition exists, the transceiver creates an alarm code that can be read on an HHT connected to the radio’s DIAG(NOSTICS) port. These codes can be very helpful in resolving many system difficul-ties.Checking for Alarms—STAT commandTo check for the presence of alarms, enter STAT on the HHT. If no alarms exist, the message NO ALARMS PRESENT appears at the top of the display.If an alarm does exist, a two-digit alarm code (00–31) is displayed, and it is identified as a major or minor alarm. A brief description of the alarm is also given. Alarm codes and their meanings are listed in Table 12.If more than one alarm exists, the word MORE appears at the bottom of the screen; additional alarms can be viewed by pressing  .Major Alarms vs. Minor AlarmsMajor alarms report serious conditions that generally indicate a hard-ware failure, or other abnormal condition that will prevent (or seriously hamper) further operation of the transceiver.With the exception of alarm code 00 (network address not pro-grammed), major alarms generally indicate the need for factory repair. Contact MDS for further assistance.Minor alarms report conditions which, under most circumstances, will not prevent transceiver operation. This includes out-of-tolerance condi-tions, baud rate mismatches, etc. The cause of these alarms should be investigated and corrected to prevent system failure.PWR SYNC TXD RXDTable 11. LED Status Indicators LED Name DescriptionPWR • Continuous—Power is applied to the radio, no problems detected.• Flashing 5 times per second—Fault indication.See Section 7.0, TROUBLESHOOTING (beginning on Page 50).• Flashing once every 4 seconds—Radio is in Sleep Mode.SYNC Lights continuously to indicate the radio is receiving/sending synchronization frames. Within 16 seconds of start-up, this LED should be lit continuously. TXD Indicates EIA-232 space signal (logic high) input to the DB-25 connector.RXD Indicates EIA-232 space signal (logic high) output from the DB-25 connector.ENTER
52 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CAlarm Code DefinitionsTable 12 contains a listing of all event codes that may be reported by the transceiver.Table 12. Alarm Codes  Alarm Code Alarm Type Description00 Major The network address is not programmed.01 Major Improper software detected for this radio model.02, 03 -- Reserved for factory use.04 Major One or more of the programmable synthesizer loops is reporting an out-of-lock condition.05 -- Reserved for factory use.06 Major Analog-to-Digital (A-to-D) fault.07 Major One or more of the radio’s internal voltage regulators is reporting a failure. The radio will not operate.08 Major The system is reporting that it has not been calibrated. Factory calibration is required for proper radio operation.09 -- Reserved for factory use.10 Major The microcontroller unit (MCU) was unable to properly program the system to the appropriate defaults. A hardware problem may exist.11 -- Reserved for factory use.12 Major Receiver time-out alarm.13-15 -- Reserved for factory use.16 Minor The unit address is not programmed.17 Minor A data parity fault has been detected on the DATA INTERFACE connector. This usually indicates a parity setting mismatch between the radio and the RTU.18 Minor A data framing error has been detected on the DATA INTERFACE connector. This may indicate a baud rate mismatch between the radio and the RTU.19–24 -- Reserved for factory use.25 Minor The 6.0 volt power regulator is out-of-tolerance. If the error is excessive, operation may fail.26 Minor The dc input voltage is out-of-tolerance. If the voltage is too far out-of-tolerance, operation may fail.27, 28 -- Reserved for factory use.29 Minor RF output power fault detected. (Power differs by more than 2 dB from set level.) Often caused by high antenna system SWR. Check antenna, feedline and connectors.30 Minor The system is reporting an RSSI reading below –105 dBm. Bit errors are likely to be present in the data.31 Minor The transceiver’s internal temperature is approaching an out-of-tolerance condition. If the temperature drifts outside of the recommended operating range, system operation may fail.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 537.3 Performing Network-Wide Remote DiagnosticsDiagnostics data from a remote radio can be obtained by connecting a laptop or personal computer running MDS Network Management Soft-ware to any radio in the network. Figure 30 shows an example of a setup for performing network-wide remote diagnostics.Invisible place holderFigure 26. Network-Wide Remote Diagnostics SetupIf a PC is connected to any radio in the network, intrusive polling (polling which briefly interrupts payload data transmission) can be per-formed. To perform diagnostics without interrupting payload data trans-mission, connect the PC to a radio defined as the “root” radio. A radio is defined as a root radio using the DTYPE ROOT command locally, at the radio.RTURTU TODIAGNOSTICSPORTTO DATAPORTREPEATERPOLLING REMOTEROOT NODEREMOTE  NODEOPERATIONIntrusive  messaging  only(not  preferred)DIAGNOSTICSCOMPUTERRUNNING InSite TO RJ-11DIAGNOSTICSPORTRTUDTYPEROOTDIAGNOSTICS  DATA(To InSite)HOST COMPUTERPAYLOAD  DATA(To  SCADA  application)ROOT  NODE  OPERATIONActive  messaging  orpassive  messaging  (preferred)
54 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CA complete explanation of remote diagnostics can be found in MDS’ Network-Wide Diagnostics System Handbook (MDS P/N 05-3467A01).1. Program one radio in the network as the root radio by entering the DTYPE ROOT command at the radio.2. At the root radio, use the DLINK ON and DLINK [baud rate] commands to configure the diagnostic link protocol on the RJ-11 port.3. Program all other radios in the network as nodes by entering the DTYPE NODE command at each radio.4. Use the DLINK ON and DLINK [baud rate] commands to configure the diagnostic link protocol on the RJ-11 port of each node radio.5. Connect same-site radios using a null-modem cable at the radios’ diagnostic ports.6. Connect a PC on which MDS Network Management Software is installed to the root radio, or to one of the nodes, at the radio’s diag-nostic port. (This PC may be the PC being used to collect payload data, as shown in Figure 30.)To connect a PC to the radio’s DIAG. port, an RJ-11 to DB-9 adapter (MDS P/N 03-3246A01) is required. If desired, an adapter cable may be constructed from scratch, using the information shown in Figure 27.Invisible place holderFigure 27. RJ-11 to DB-9 Adapter CableTable 13. Network-Wide Diagnostics Radio Setup CommandsCOMMAND DESCRIPTION NETWORK-WIDEDIAGNOSTICSCONFIGURATIONDLINK [xxxxx]                          Details Page 55 Set baud rate of diagnostics linkDTYPE [NODE/ROOT/GATE/PEER]                          Details Page 55Set radio’s operational characteristics for network-wide diagnosticsRXDTXDGND235DB-9 FEMALE(TO COMPUTER)TXDRXDGND456RJ-11 PLUG(TO RADIO)RJ-11 PIN LAYOUT16
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 557. Launch the MDS Network Management application at the PC. (Refer to the software user’s manual for details.)DLINK [xxxxx]DLINK followed by the baud rate sets the baud rate (bps) of the diagnos-tics link. The following DLINK baud rates selections are allowed:• 1200• 2400• 4800• 9600• 19200 (default setting)Example: DLINK 4800 sets the RJ-11 DIAG port to operate at 4800 bps. The default is DLINK 19200 and DLINK ON.NOTE: The same baud rate must be entered into the appropriatefield(s) of any Network Management Software, if used.DTYPE [NODE/ROOT/GATE/PEER]The DTYPE command specifies the radio’s operational characteristics for network-wide diagnostics. There are four possible types of nodes in a network-wide diagnostics system.The common types are:•NODE–The most common setting, and the default. This is the basic system radio device-type. Typically, the radio network is comprised of nodes and one root. Intrusive diagnostics can orig-inate from any node. However, non-intrusive diagnostics can not be facilitated through a node.•ROOT–Always one, and only one, per network. The root is the focal point of network-wide diagnostics information. Intrusive diagnostics can originate from any radio, including the root. However, the root is the only radio enabling non-intrusive diag-nostics.The default radio device-type is NODE. Less used are:•GATE•PEERThese node types are needed for repeater sub-networks and simplex sub-networks where simplex frequencies are used. See the Net-work-Wide Diagnostics System Handbook for an explanation of these node types.
56 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C7.4 Troubleshooting ChartTable 14 provides suggestions for resolving system difficulties that may be experienced in the radio system. If problems persist, contact the fac-tory for further assistance. Refer to the inside back cover of this guide for contact information.8.0 TECHNICAL REFERENCEThe following section contains material that is not essential to using the radio, but may prove helpful in diagnosing performance problems or in gaining a better understanding of the unit’s operation.8.1 Technical SpecificationsGENERALFrequency Hopping Range: Up to 1019 frequencies within:902–928 MHz,configurable in 3.2 MHz zonesHop Pattern: Based on network addressFrequency Stability: ±1.5 ppmSimplex Operation: User selectableHalf-Duplex Operation: ±1.6 MHz TX/RX splitTable 14. Troubleshooting ChartDifficulty Recommended System ChecksUnit isinoperative. a. Check for the proper supply voltage at the power connector.b. The transceiver’s internal resettable fuse may have tripped. To reset it, momentarily remove and re-apply power to the radio.Interference is suspected. a. Verify that the system has a unique network address. Nearby systems with the same address will cause interference.b. Use the ZONE DATA command (Page 49) to check for interference in specific zones. Lock out affected zone(s) using the SKIP command (Page 46).c. If omnidirectional antennas are used on remote stations, consider changing to directional antennas. This will often limit interference to and from other stations.No synchronization with master, or poor overall performance.a. Check for secure interface connections at the radio and the connected device.b. Check the antenna, feedline and connectors. Reflected power should be less than 10% of the forward power reading (SWR ≈2:1 or lower).c. If the remote radio is in synchronization, but performance is poor, check the received signal strength using the RSSI command (Page 42). If RSSI is low, it may indicate antenna problems, or misalignment of directional antenna headings.d. Verify proper programming of system parameters: mode, network address, data interface baud rate, transmitter power, CTS delay, etc. It may be helpful to use the INIT command (Page 41), which resets all parameters to factory defaults.e. Check for alarms using the STAT command (Page 47)
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 57Network Addresses: 65,000Temperature Range: –30°C to +60°CHumidity: 95% at +40°C; non-condensingPrimary Power: 13.8 Vdc (10.5–30 Vdc range)** Transceivers shipped prior to Revision “U” (November 1999) may be configured for 25 Vdc maximum DC input.Supply Current (typical):Transmit: 400 mA @ 13.8 VdcReceive: 125 mA @ 13.8 VdcSleep Mode: <30 mA @ 13.8 VdcSize (excluding mtg. hardware): 2.0" x 5.62" x 7.25"51 x 143 x 184 mmWeight: 2.38 lb/1.08 kgCase: Die-cast aluminumApprovals: • FCC Part 15.247• Industry Canada RSS-210 and RSS-139• CSA/US Class 1, Div. 2; Groups A, B, C and D hazardous locations• Contact MDS for information on availability andgovernmental approvals in other countriesDATA CHARACTERISTICSData Interface: EIA-232 signaling standardInterface Connector: DB-25 femaleData Rate: 1200, 2400, 4800, 9600, 19200, 38400 bpsasynchronousData Latency: <10 ms typical (buffer off)Byte Length: 10 or 11 bitsMaximum Data Transmission: Continuous up to 19200 bps;Non-continuous at 38400 bpsRF CHARACTERISTICSTRANSMITTER:Power Output(at antenna connector): 0.1 to 1.0 watt (+20 dBm to +30 dBm) ±1.0 dB, set by userDuty Cycle: ContinuousModulation Type: Binary CPFSKOutput Impedance: 50 OhmsSpurious: –60 dBcHarmonics: –80 dBcRECEIVERType: Double conversion superheterodyneBit-Error Rate: Less than 1x10-6 at –110 dBmIntermodulation: 59 dB minimum (EIA)
58 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CDesensitization: 75 dBSpurious: 70 dB minimumBandwidth: 25 kHzInterference Ratio(BER degraded by 10-1): Co-channel: –10 dBAdjacent channel: +30 dBTwo channels away: +50 dBThree channels away: +60 dBTime Required to Synchronizewith Master Radio: Less than 13 seconds (typical)8.2 RSSI Checks with a VoltmeterAs an alternative to the HHT method of measuring RSSI (see Antenna Aiming on page 27), a dc voltmeter may be connected to Pin 21 of the transceiver’s DATA INTERFACE connector.Figure 28 shows the relationship between RSSI and the dc voltage at Pin 21.NOTE: RSSI Readings are not accurate for incoming signals strongerthan –50 dBm.)Invisible place holderFigure 28. RSSI vs. Vdc at Pin 21 of DATA INTERFACE Connector8.3 Data Interface Connections (DB-25)The DATA INTERFACE connector is used to connect the radio to an external DTE data terminal that supports the EIA-232 format. The radio supports data rates of 1200, 2400, 4800, 9600, 19200 and 38400 bps (asynchronous data only).The DATA INTERFACE connector mates with a standard DB-25 plug that is available from many electronics parts distributors. Figure 29 shows the layout of the DATA INTERFACE connector.Table 15 lists each pin on the connector and describes its function.22.533.54–110–90–70–50+ DC VOLTS (PIN 21)SIGNAL LEVEL (dBm)4.55.0
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 59Invisible place holderFigure 29. Data Interface Connector (DB-25) Pins(As viewed from outside the radio)UnusedRadio Inhibit (Sleep)Unused13121110987654321Receiver Unsquelched SensorUnusedData Carrier Detect (DCD)Signal Ground*Data Set Ready (DSR)Clear-to-Send Output (CTS)Request-to-Send Input (RTS)Received Data (RXD)*Transmitted Data (TXD)*Protective Ground252423222120191817161514Alarm  OutputAnalog Input PinDiagnostic Channel EnableRSSI Voltage9.9 Vdc Regulated OutputUnregulated DC Input/OutputDigital Output PinUnusedUnusedUnusedPinDescription PinNo. PinNo. PinDescriptionUnused Future use— do not connect* Required in most installationsTable 15. Data Interface Connector (DB-25) Pin Descriptions PinNumber Input/Output Pin Description1--Protective GroundConnects to ground (negative supply potential) on the radio’s PC board and chassis.2INTXD—Transmitted DataAccepts TX data from the connected device.3 OUT RXD—Received DataSupplies received data to the connected device.4INRTS—Request-to-Send Input5 OUT CTS—Clear-to-Send OutputGoes “high” after the programmed CTS delay time has elapsed (DCE), or keys an attached radio when RF data arrives (CTS KEY).6 OUT DSR—Data Set ReadyProvides a +6 Vdc DSR signal through a 2.5 kΩ resistor.7--Signal GroundConnects to ground (negative supply potential) at the radio’s PC board.8 OUT DCD—Data Carrier DetectA “high” indicates hopping synchronization.9 -- Unused.10 OUT RUS—Receiver Unsquelched SensorProvides +8 Vdc through a 1 kΩ resistor whenever the receiver squelch is open, and drops to less than 1 Vdc when the squelch is closed.11 -- Unused.12 IN Sleep ModeA ground on this pin turns off most circuits in the radio, including transmit, receive, modem and diagnostic functions. This allows for greatly reduced power consumption, yet preserves the radio’s ability to be quickly brought on line. See Section 4.6, Using the Radio’s Sleep Mode (beginning on Page 25) for details.13 -- Unused.
60 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. C8.4 Bench Testing SetupFigure 30 shows a sample test setup that can be used to verify the basic operation of MDS radios. This test can be performed with any number of remote radios by using a power divider with the required number of output connections.14 -- Unused.15 -- Do not connect—Factory test point.16 -- Unused.17 -- Digital Output PinOutput value is 3 Vdc for set and 0 Vdc for clear. May be activated via MDS Network Management Software. 18 IN/OUT Accessory PowerUnregulated input/output. Provides a source of power for low-current accessories. The supply voltage may be between 11.0 and 25 volts.19 OUT 9.9 Vdc Regulated OutputProvides a source of regulated voltage at 100 mA for low-power accessories.20 -- Do not connect—Reserved for future use.21 OUT RSSI—Received Signal Strength IndicationA dc voltmeter may be connected to this pin to read the relative strength of the incoming signal. Figure 28 on page 58 compare RSSI to dc voltage.22 -- Unused.23 IN Diagnostic Channel EnableA ground on this pin causes the radio’s microcontroller to open the DB-25 DATA INTERFACE connector for diagnostics and control (in place of the more commonly used RJ-11 DIAG(NOSTICS) connector).24 IN Analog Input PinInput value can range between 0 and 5 volts DC. Voltage must not exceed 5 Vdc or damage may result. Analog input voltage may be monitored via MDS Network Management software, where the 0-5 Vdc range is translated to a value between 0 and 255 (hex address 0xFF).25 OUT Alarm OutputA logic low (less than 0.5 volts) on this pin indicates normal operation. A logic high (greater than 4 volts) indicates that an alarm condition is present. This pin can be used as an alarm output, provided the internal series resistance of 1 kΩ is considered.Table 15. Data Interface Connector (DB-25) Pin PinNumber Input/Output Pin Description
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 61The RTU simulator shown in the test setup (MDS Part No. 03-2512A01) is a microcontroller that emulates a remote terminal unit operating at 1200, 2400, 4800, or 9600 bps. Custom software is supplied with the RTU simulator that allows continuous polling of remote radios. The software reports the number of polls sent, polls received, and the number of errors detected. The software runs on an IBM-compatible personal computer.NOTE: It is very important to use attenuation between all units in thetest setup. The amount of attenuation required will depend onthe number of units being tested and the desired signal strength(RSSI) at each transceiver during the test. In no case should asignal greater than –50 dBm be applied to any transceiver inthe test setup.Invisible place holderFigure 30. Typical Setup for Bench Testing of Radios8.5 Using Radio Configuration Software Windows-based Radio Configuration software (MDS P/N 03-3156A01) is used for upgrading the internal radio software when new features become available from Microwave Data Systems. The software includes on-line user instructions, and an installation booklet is provided with the software package. Contact MDS for ordering information.NOTE: The latest firmware revision for all MDS products may beobtained at www.microwavedata.com.Connecting a PCTo connect a PC to the radio’s DIAG(NOSTICS) port, an RJ-11 to DB-9 adapter cable (MDS P/N 03-3246A01) is required. If desired, this cable may be constructed from scratch using the information shown in Figure 31.ANTENNA13.8VDC+ –ANTENNA13.8VDC+ –ANTENNA13.8VDC+ –POWER ATTENUATORS• Fixed or adjustable• 2W Minimum RatingPOWER DIVIDERNON-RADIATING ATTENUATORS• Install on Unused  Divider Ports (if any)• 2W Minimum RatingRTU SIMULATORSMDS P/N 03-2512A01REMOTEREMOTEREMOTECOMPUTER RUNNINGMDS POLLING SOFTWAREANTENNA13.8VDC+ –MASTER
62 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CUpgrading the Radio’s SoftwareUsing the Radio Configuration software, select RADIO SOFTWARE UPGRADE under the SYSTEM menu. Follow the prompts and on-line instructions to complete the upgrade procedure.Software upgrades are distributed as ASCII files with a .S28 extension. These files use the Motorola S-record format. When the download is activated, the radio’s PWR LED will flash rapidly, confirming that a download is in process. The download takes about two minutes.NOTE: If a download fails, the radio is left unprogrammed and inop-erative. This is indicated by the PWR LED flashing slowly (1second on/1 second off). This condition is only likely to occurif there is a power failure to the computer or radio during thedownloading process. The download can be attempted againwhen the fault has been corrected.Invisible place holderFigure 31. RJ-11 to DB-9 Adapter Cable(for software upgrade using connected PC)RXDTXDGND235DB-9 FEMALE(TO COMPUTER)TXDRXDGND456RJ-11 PLUG(TO RADIO)RJ-11 PIN LAYOUT16
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 638.6 dBm-Watts-Volts Conversion ChartTable 16 is provided as a convenience for determining the equivalent voltage or wattage of an RF power expressed in dBm.Table 16. dBm-Watts-Volts Conversion—for 50 ohm Systems9.0 GLOSSARY OF TERMSIf you are new to spread spectrum radio, some of the terms used in this guide may be unfamiliar. The following glossary explains many of these terms and will prove helpful in understanding the operation of the trans-ceiver.dBm V Po+53 100.0 200W+50 70.7 100W+49 64.0 80W+48 58.0 64W+47 50.0 50W+46 44.5 40W+45 40.0 32W+44 32.5 25W+43 32.0 20W+42 28.0 16W+41 26.2 12.5W+40 22.5 10W+39 20.0 8W+38 18.0 6.4W+37 16.0 5W+36 14.1 4W+35 12.5 3.2W+34 11.5 2.5W+33 10.0 2W+32 9.0 1.6W+31 8.0 1.25W+30 7.10 1.0W+29 6.40 800mW+28 5.80 640mW+27 5.00 500mW+26 4.45 400mW+25 4.00 320mW+24 3.55 250mW+23 3.20 200mW+22 2.80 160mW+21 2.52 125mW+20 2.25 100mW+19 2.00 80mW+18 1.80 64mW+17 1.60 50mW+16 1.41 40mW+15 1.25 32mW+14 1.15 25mW+13 1.00 20mW+12 .90 16mW+11 .80 12.5mW+10 .71 10mW+9 .64 8mW+8 .58 6.4mW+7 .500 5mW+6 .445 4mW+5 .400 3.2mW+4 .355 2.5mW+3 .320 2.0mW+2 .280 1.6mW+1 .252 1.25mWdBm V Po0 .225 1.0mW-1 .200 .80mW-2 .180 .64mW-3 .160 .50mW-4 .141 .40mW-5 .125 .32mW-6 .115 .25mW-7 .100 .20mW-8 .090 .16mW-9 .080 .125mW-10 .071 .10mW-11 .064-12 .058-13 .050-14 .045-15 .040-16 .0355dBm mV Po-17 31.5-18 28.5-19 25.1-20 22.5 .01mW-21 20.0-22 17.9-23 15.9-24 14.1-25 12.8-26 11.5-27 10.0-28 8.9-29 8.0-30 7.1 .001mW-31 6.25-32 5.8-33 5.0-34 4.5-35 4.0-36 3.5-37 3.2-38 2.85-39 2.5-40 2.25 .1µW-41 2.0-42 1.8-43 1.6-44 1.4-45 1.25-46 1.18-47 1.00-48 0.90dBm mV Po-49 0.80-50 0.71 .01µW-51 0.64-52 0.57-53 0.50-54 0.45-55 0.40-56 0.351-57 0.32-58 0.286-59 0.251-60 0.225 .001µW-61 0.200-62 0.180-63 0.160-64 0.141dBm µV Po-65 128-66 115-67 100-68 90-69 80-70 71 .1nW-71 65-72 58-73 50-74 45-75 40-76 35-77 32-78 29-79 25-80 22.5 .01nW-81 20.0-82 18.0-83 16.0-84 11.1-85 12.9-86 11.5-87 10.0-88 9.0-89 8.0-90 7.1 .001nW-91 6.1-92 5.75-93 5.0-94 4.5-95 4.0-96 3.51-97 3.2dBm µV Po-98 2.9-99 2.51-100 2.25 .1pW-101 2.0-102 1.8-103 1.6-104 1.41-105 1.27-106 1.18dBm nV Po-107 1000-108 900-109 800-110 710 .01pW-111 640-112 580-113 500-114 450-115 400-116 355-117 325-118 285-119 251-120 225 .001pW-121 200-122 180-123 160-124 141-125 128-126 117-127 100-128 90-129 80 .1ƒW-130 71-131 61-132 58-133 50-134 45-135 40-136 35-137 33-138 29-139 25-140 23 .01ƒW
64 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CAntenna System Gain—A figure, normally expressed in dB, repre-senting the power increase resulting from the use of a gain-type antenna. System losses (from the feedline and coaxial connectors, for example) are subtracted from this figure to calculate the total antenna system gain.Bit—The smallest unit of digital data, often represented by a one or a zero. Eight bits (plus start, stop, and parity bits) usually comprise a byte.Bits-per-second—See BPS.BPS—Bits-per-second. A measure of the information transfer rate of digital data across a communication channel.Byte—A string of digital data usually made up of eight data bits and start, stop and parity bits.Decibel (dB)—A measure of the ratio between two signal levels. Fre-quently used to express the gain (or loss) of a system.Data Circuit-terminating Equipment—See DCE.Data Communications Equipment—See DCE.Data Terminal Equipment—See DTE.dBi—Decibels referenced to an “ideal” isotropic radiator in free space. Frequently used to express antenna gain.dBm—Decibels referenced to one milliwatt. An absolute unit used to measure signal power, as in transmitter power output, or received signal strength.DCE—Data Circuit-terminating Equipment (or Data Communications Equipment). In data communications terminology, this is the “modem” side of a computer-to-modem connection. By default, MDS transceivers are set as DCE devices.Digital Signal Processing—See DSP.DSP—Digital Signal Processing. In the MDS 9810 transceiver, the DSP circuitry is responsible for the most critical real-time tasks; primarily modulation, demodulation, and servicing of the data port.DTE—Data Terminal Equipment. A device that provides data in the form of digital signals at its output. Connects to the DCE device.Equalization—The process of reducing the effects of amplitude, fre-quency or phase distortion with compensating networks.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide 65Fade Margin—The greatest tolerable reduction in average received signal strength that will be anticipated under most conditions. Provides an allowance for reduced signal strength due to multipath, slight antenna movement or changing atmospheric losses. A fade margin of 20 to 30 dB is usually sufficient in most systems.Frame—A segment of data that adheres to a specific data protocol and contains definite start and end points. It provides a method of synchro-nizing transmissions.Frequency Hopping—The spread spectrum technique used by the MDS 9810 transceiver, where two or more associated radios change their operating frequencies several times per second using a set pattern. Since the pattern appears to jump around, it is said to “hop” from one frequency to another.Frequency Zone—The transceivers use up to 1,019 discrete channels in the 902 to 928 MHz spectrum. A group of 128 channels is referred to as a zone. The transceivers use eight frequency zones. (Five channels are reserved for network control purposes.)Hardware Flow Control—A transceiver feature used to prevent data buffer overruns when handling high-speed data from the RTU or PLC. When the buffer approaches overflow, the radio drops the clear-to-send (CTS) line, which instructs the RTU or PLC to delay further transmis-sion until CTS again returns to the high state.Host Computer—The computer installed at the master station site, which controls the collection of data from one or more remote sites.Latency—The delay (usually expressed in milliseconds) between when data is applied to TXD (Pin 2) at one radio, until it appears at RXD (Pin 3) at the other radio.MAS—Multiple Address System. A radio system where a central master station communicates with several remote stations for the pur-pose of gathering telemetry data. Figure 3 on page 3 shows an example of an MAS system.Master (Station)—The one radio transceiver in a spread spectrum net-work that automatically provides synchronization information to one or more associated remote transceivers. A radio may be programmed for either master or remote mode using software commands. See Section 6.0, PROGRAMMING (beginning on Page 28).MCU—Microcontroller Unit. This is the processor responsible for con-trolling system start-up, synthesizer loading, hop timing, and key-up control.Microcontroller Unit—See MCU.
66 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CMode—This refers to the programmed function of an MDS spread spec-trum radio—master or remote. (See also Remote Station and Master Sta-tion.)Multiple Address System (MAS)—See Point-Multipoint System.Network Address—User-selectable number between 1 and 65000 that is used to identify a group of transceivers that form a communications network. The master and all remotes within a given system must have the same network address.Network-Wide Diagnostics—An advanced method of controlling and interrogating MDS radios in a radio network. It works by interspersing diagnostic data with payload data.Point-Multipoint System—A radio communications network or system designed with a central control station that exchanges data with a number of remote locations equipped with terminal equipment.Poll—A request for data issued from the host computer (or master PLC) to a remote radio.PLC—Programmable Logic Controller. A dedicated microprocessor configured for a specific application with discrete inputs and outputs. It can serve as a host or as an RTU.Remote Radio—A radio in a spread spectrum network that communi-cates with an associated master station. A radio may be programmed for either master or remote mode using software commands. See Section 6.0, PROGRAMMING (beginning on Page 28).Remote Terminal Unit—See RTU.RTU—Remote Terminal Unit. A data collection device installed at a remote radio site.SCADA—Supervisory Control And Data Acquisition. An overall term for the functions commonly provided through an MAS radio system.Standing Wave Ratio—See SWR.SWR—Standing Wave Ratio. A parameter related to the ratio between forward transmitter power and the reflected power from the antenna system. As a general guideline, reflected power should not exceed 10% of the forward power (≈ 2:1 SWR).Zone—See Frequency Zone.
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide I-1INDEXAACCESS DENIED error message 31Accessories (table) 7ADDR command (set/display radio network address) 36Alarmchecking for 51code definitions 52codes 51codes, table 52major vs. minor 51output pin (Pin 25) 60receiver timeout (RXTOT command) 43reset output signal 36set/display output sense (ASENSE command) 36status (STAT command) 47ALARM command (obsolete; see STAT command) 47AMASK command (configure alarm output signal) 36Antennainstallation 16performance optimization 26selection 11SWR check 27system gain vs. power output setting, table 14system gain, defined 64Yagi, illustrated 12ASENSE command (set/display alarm output sense) 36BBAUD command (set/display data interface port attributes) 36Baud ratesetting 28setting for RJ-11 DIAG port (DLINK command) 54Baud rate (diagnostics link) 39, 55Bit, defined 64BPS (bits-per-seond), defined 64BUFF command (set/display received data handling mode) 37Byte, defined 64CCableadapter, for connecting diagnostics PC to radio 54, 62adapter, RJ-11 to DB-9 (illustrated) 54, 62data equipment to DATA INTERFACE connector 16data interface wiring for null-modem 23, 24data interface wiring for peer-to-peer systems with repeater assistance 21data interface wiring for tail-end links 22feedlines 12HHT to radio (coiled cord) 28local interface for repeater system 21maximum length, recommended 17null-modem, for repeater system 22, 23null-modem, for same-site radios 54power (positive/negative leads) 17COMMAND FAILED error message 31CommandsADDR (set/display radio network address) 36AMASK (configure alarm output signal) 36ASENSE (set/display alarm output sense) 36BAUD (set/display data interface port attributes) 36BUFF (set/display received data handling mode) 37CTS (set/display CTS line response timer) 37CTSHOLD (set/display CTS hold timer) 38detailed descriptions 32–50DEVICE (set/display DCE or CTS Key behavior) 38display operating status 34DLINK (set/display baud rate of diagnostics link) 39DMGAP (set time to wait between characters) 39DTYPE (set radio’s diagnopstics type) 39entering on Hand-Held Terminal (HHT) 30Hand-Held Terminal (HHT) 30HOPTIME (set/display hoptime setting) 40how used 35INIT (restore factory default settings) 41MODE (set/display master/remote operation) 41most used 32, 35network configuration 32, 54OWM (set/display optional owner’s message) 42OWN (set/display optional owner’s name) 42PWR (set/display RF forward output power) 42RSSI (display received signal strength) 42RTU (enable/disable internal RTU) 43RX (set/display test receive frequency) 43RXTOT (set/display received data timeout value) 43SEND (set/display number of re-sends) 43set/program 33SETUP (enter testing and setup mode) 44SHOW (display active port, dc volts, measured power output) 45SIMPLEX (set/display simplex/half-duplex operation) 45SKIP (set/display frequency zone to skip) 46SKIPSYNC (set/display status of SYNC messages in skipped zones) 46SNR (display signal-to-noise ratio) 46SREV (display transceiver software version) 47STAT (list alarms) 47summary, table 32TDD (set/display time division multiplex status) 47TEMP (display internal temperature) 48CTS command (set/display CTS line response timer) 37CTSHOLD command (set/display CTS hold timer) 38DData buffer setting 27, 37DATA INTERFACEconnections 58connector pin descriptions, table 59connector pins, illustrated 59connector, RSSI vs. V dc at Pin 21 of (illustrated) 58Data interfacecable wiring for peer-to-peer systems with repeater assistance 21cable wiring for repeater, illustrated 23, 24cable wiring for tail-end links, illustrated 22setting parameters 19
I-2 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. CdBi, defined 64dBm, defined 64DCE, defined 64Decibel (dB), defined 64Default settingsdata interface baud rate 28factory settings reset by INIT command (table) 41re-initializing HHT to 29restoring (INIT command) 41See also individual command descriptionsDEVICE command (set/display DCE or CTS Key behavior) 38Diagnosticsnetwork-wide, performing 53setup mode (SETUP command) 44using InSite software for network-wide 53Displayalarm output sense (ASENSE command) 36alarms (STAT command) 47connector port, diagnostics (SHOW command) 45CTS hold timer value (CTSHOLD command) 38CTS line response timer value (CTS command) 37data interface baud rate (BAUD command) 36dc input/output voltages (SHOW command) 45device behavior (DEVICE command) 38hoptime setting (HOPTIME command) 40master or remote operation (MODE command) 41network address (ADDR command) 36operating status commands 34owner’s message (OWM command) 42owner’s name (OWN command) 42received data handling mode (BUFF command) 37received data timeout value (RXTOT command) 43received signal strength (RSSI command) 42RF forward output power (PWR command) 42RF power output, actual measured (SHOW command) 45signal-to-noise ratio (SNR command) 46simplex or half-duplex operation (SIMPLEX command) 45skipped frequency zones (SKIP command) 46software version, transceiver (SREV command) 47temperature, internal (TEMP command) 48test receive frequency (RX command) 43DKEY command (dekey transmitter) 27, 35, 45DLINK command (set/display baud rate of diagnostics link) 39, 54, 55DMGAP command (set/display time to wait between characters) 39DSP (Digital Signal Processing), defined 64DTE, defined 64DTYPE command (set radio’s diagnostics type) 39, 54, 55EEEPROM FAILURE error message 32Enablediagnostics channel by grounding Pin 23 of HHT cable 29HHT setup mode 29internal RTU (RTU command) 43master/remote operation (MODE command) 41network-wide diagnostics, procedures 54Setup mode (SETUP command) 44simplex/half-duplex operation (SIMPLEX command) 45skipped zone (SKIP command) 46Sleep Mode 25Equalization, defined 64Error messageson Hand-Held Terminal (HHT) 31FFade margin, defined 65Feedlineselection 11, 12Frame, defined 65Frequency hopping, defined 65Frequency zonedefined 65table 46GGate (radio diagnostics type) 39, 55Glossary 63–66HHand-Held Terminal (HHT)command summary, table 32connected to transceiver, illustrated 18, 29connection and start-up 28entering commands 30error messages 31keyboard commands 30operational settings, table 30re-initialization 29setup display, illustrated 30Hardware flow control, defined 65Hopping, defined 65Hoptimeparameters, table 40setting 27HOPTIME command (set/display hoptime setting) 40Host computer, defined 65IIllustrationsantenna, Yagi 12bench test setup 61data interface cable wiring 21data interface cable wiring for repeater 23, 24data interface cable wiring for tail-end links 22DATA INTERFACE connector pins 59HHT connected to transceiver 18, 29HHT setup display 30LED status indicators 26model configuration code 2network-wide diagnostics 53peer-to-peer network with repeater assistance 5, 20point-to-point link 5remote station arrangement 8repeater system configuration 6RJ-11 to DB-9 adapter 62RJ-11 to DB-9 adapter cable 54RSSI vs. V dc at Pin 21 of DATA INTERFACE connector 58simplex peer-to-peer network 4tail-end link 6transceiver 1typical MAS network 3INCORRECT ENTRY error message 31INIT command (restore factory default settings) 41InSite software 53Installation 14–25antenna 16configuring the transceiver 17connecting transceiver to data equipment 16
MDS 05-3301A01, Rev. C MDS 9810 Installation and Operation Guide I-3feedline selection 12peer-to-peer systems 19performance optimization 26primary power 17programming network address 18repeaters 22requirements 7setting data interface parameters 19site selection 8site survey 9tail-end links 21transmission path 8Interferenceabout 10checks 28troubleshooting 56KKeyset to CTS keying (DEVICE command) 38transmitter, for antenna SWR check 27KEY command (key transmitter) 27, 35, 45LLatency, defined 65LED status indicatorsillustrated 26table 26MMaster Stationdefault settings 41defined 65MCU (Microcontroller Unit), defined 65MDS Radio Configuration software 61MODE command (set/display master/remote operation) 41Mode, defined 66Model configuration code, illustrated 2Mounting instructions 15Multiple Address System (MAS)defined 65network, illustrated 3NNetwork addressdefined 66programming 18Network configuration commands 32, 54Network-wide diagnosticsdefined 66illustrated 53procedures 53Node (radio diagnostics type) 39, 55NOT AVAILABLE error message 31NOT PROGRAMMED error message 31OOperation 26–28OWM command (set/display optional owner’s message) 42OWN command (set/display optional owner’s name) 42PPASSWORD INVALID error message 31PCconnecting to radio for software upgrade 62connecting to radio’s diagnostic port 54launching InSite application at 55performing diagnostics using connected 53Peer (radio diagnostics type) 39, 55Peer-to-peer networkinstallation 19with repeater assistance, illustrated 5, 20Performance optimization 26Pins, DATA INTERFACE connector descriptions (table) 59PLC (Programmable Logic Controller), defined 66Point-to-multipoint systemdefined 66power usage 13Point-to-point systemlink, illustrated 5Poll, defined 66Powerhow much can be run 13measuring and installing primary 17set/display RF forward output (PWR command) 42sleep mode 25Proceduresantenna aiming 27antenna and feedline selection 11antenna SWR check 27configuring the transceiver 17connecting data equipment to DATA INTERFACE connector 16connecting PC and radios for network-wide diagnostics 54enabling sleep mode 25entering commands using Hand-Held Terminal (HHT) 30Hand-Held Terminal (HHT) connection and start-up 28Hand-Held Terminal (HHT) set-up 29installation 14–25installation planning 7installing the antenna and feedline 16interference check 28measuring and installing primary power 17mounting the transceiver 15network-wide diagnostics 53performance optimization 26performing network-wide diagnostics 53programming radio for network-wide diagnostics 54programming the radio 28–32reading LED status indicators 26site selection 8troubleshooting 50–56Programming radio 28–50as root or node 54PWR command (set/display RF forward output power) 42RRadiobench test setup, illustrated 61bench testing setup 61checking RSSI with voltmeter 58connecting PC to (for software upgrade) 62inoperative (troubleshooting chart) 56no synchronization with master (troubleshooting chart) 56poor performance (troubleshooting chart) 56Remote radiodefault settings 41defined 66Remote stationtypical arrangement, illustrated 8Repeater
I-4 MDS 9810 Installation and Operation Guide MDS 05-3301A01, Rev. Cdata interface cable wiring for, illustrated 23, 24installation 22installing peer-to-peer with 20system, illustrated 6using single radio for 24Root (radio diagnostics type) 39, 55RSSIchecking with voltmeter 58RSSI command (display received signal strength) 42RTU (Remote Terminal Unit)defined 66simulator (used in test setup) 61RTU command (enable/disable internal RTU) 43RX command (set/display test receive frequency) 43RXTOT command (set/display received data timeout value) 43SSCADA (Supervisory Control and Data Acquisition), defined 66SEND command (set/display number of re-sends) 43Setalarm output sense (ASENSE command) 36alarm output signal (AMASK command) 36CTS hold timer (CTSHOLD command) 38CTS line response timer (CTS command) 37data interface baud rate (BAUD command) 36DCE or CTS Key device behavior (DEVICE command) 38frequency zone to skip (SKIP command) 46hoptime (HOPTIME command) 40master/remote operation (MODE command) 41network address (ADDR command) 36owner’s message (OWM command) 42owner’s name (OWN command) 42received data handling mode (BUFF command) 37received data timeout value (RXTOT command) 43simplex or half-duplex operation (SIMPLEX command) 45test receive frequency (RX command) 43testing mode (SETUP command) 44Set/program commands 33SETUP command (enter testing and setup mode) 44SHOW command (display active port, dc volts, measured power output) 45Simplexinstalling peer-to-peer system 19peer-to-peer network, illustrated 4SIMPLEX command (set/display simplex/half-duplex operation) 45Single-radio repeater 24Site selection 8SKIP command (set/display frequency zone to skip) 46SKIPSYNC (set/display status of SYNC messages in skipped zones) 46Sleep mode 25SNR command (display signal-to-noise ratio) 46Softwarecable connection for upgrade 62radio configuration 61SREV command (display transceiver software version) 47STAT command (list alarms) 47SWR (Standing Wave Ratio)defined 66performance optimization 27TTablesaccessories 7alarm codes 52antenna system gain vs. power output setting 14DATA INTERFACE connector pin descriptions 59frequency zones 46Hand-Held Terminal (HHT) command summary 32HHT operational settings 30hop time parameters 40LED status indicators 26troubleshooting 56Tail-end linkcable wiring for, illustrated 22illustrated 6installation 21TDD (set/display time division multiplex status) 47Technical reference 56–63Technical specifications 56–58TEMP command (display internal temperature) 48Temperature, display internal (TEMP command) 48Testingbench setup 61bench setup, illustrated 61TEXT TOO LONG error message 31Transceiverconfiguring 17connected to HHT, illustrated 18connecting to data equipment 16default settings 41HHT connected to, illustrated 29illustrated 1mounting instructions 15performance optimization 26sleep mode 25Troubleshooting 50–56performing network-wide diagnostics 53table 56UUNKNOWN COMMAND error message 31
IN CASE OF DIFFICULTY...MDS products are designed for long life and trouble-free operation. However, this equipment, as with all electronic equipment, may have an occasional component failure. The following informa-tion will assist you in the event that servicing becomes necessary.TECHNICAL ASSISTANCETechnical assistance for MDS products is available from our Technical Support Department during business hours (8:00 A.M.–5:30 P.M. Eastern Time). When calling, please give the complete model number of the radio, along with a description of the trouble/symptom(s) that you are expe-riencing. In many cases, problems can be resolved over the telephone, without the need for returning the unit to the factory. Please use one of the following means for product assistance:Phone: 585 241-5510  E-Mail: TechSupport@microwavedata.comFAX: 585 242-8369 Web: www.microwavedata.comFACTORY SERVICEComponent level repair of radio equipment is not recommended in the field. Many components are installed using surface mount technology, which requires specialized training and equipment for proper servicing. For this reason, the equipment should be returned to the factory for any PC board repairs. The factory is best equipped to diagnose, repair and align your radio to its proper operating specifications.If return of the equipment is necessary, you will be issued a Service Request Order (SRO) number. The SRO number will help expedite the repair so that the equipment can be repaired and returned to you as quickly as possible. Please be sure to include the SRO number on the outside of the ship-ping box, and on any correspondence relating to the repair. No equipment will be accepted for repair without an SRO number.A statement should accompany the radio describing, in detail, the trouble symptom(s), and a description of any associated equipment normally connected to the radio. It is also important to include the name and telephone number of a person in your organization who can be contacted if additional information is required.The radio must be properly packed for return to the factory. The original shipping container and packaging materials should be used whenever possible. All factory returns should be addressed to:Microwave Data SystemsProduct Services Department(SRO No. XXXX)175 Science ParkwayRochester, NY 14620 USAWhen repairs have been completed, the equipment will be returned to you by the same shipping method used to send it to the factory. Please specify if you wish to make different shipping arrange-ments. To inquire about an in-process repair, you may contact our Product Services Group at 585-241-5540 (FAX: 585-242-8400), or vie e-mail at ProductServices@microwavedata.com.
Microwave Data Systems Inc.Rochester, NY 14620General Business: +1 585 242-9600FAX: +1 585 242-9620Web: www.microwavedata.com175 Science ParkwayA product of Microwave Data Systems Inc.

Navigation menu