GE MDS DS-INETII Wireless IP/Ethernet Transceiver User Manual 2806E 1 iNET Series
GE MDS LLC Wireless IP/Ethernet Transceiver 2806E 1 iNET Series
GE MDS >
Users Manual Revised
User s Guide
MDS 05-2806A01, Rev. E.1
DECEMBER 2005
Wireless IP/Ethernet Transceiver
Firmware Release 4
MDS iNET 900™
Series
Microwave Data Systems Inc.
POWER SUPPLY
13.8 VDC @ 580 mA (Max.)
(10.5–30 Vdc)
Negative Ground Only
DATA TERMINAL
EQUIPMENT OR
LAN/WAN
COMPUTER
W/TERMINAL
EMULATOR
TRANSCEIVER
LOW-LOSS FEEDLINE
QUICK-ST
QUICK-START INSTRUCTIONS
ART INSTRUCTIONS
ANTENNA
SYSTEM
INSTALLATION SUMMARY
Step 1 – Mount the Transceiver
Step 2 – Install the Antenna
Step 3 – Measure & Connect Primary Power (10.5–30 Vdc)
Step 4 – Review the transceiver’s Configuration
Device Mode—Access Point, or Remote (Default)
Network Name—Unique name for each radio network.
Required for Remotes to associate with Access Point.
IP Address—Must be a unique number to allow for IP access
through the Ethernet Port.
NOTE: A unique IP address is essential to access the browser-based
Management System.
RF Output Power—Adjust as necessary for regulatory compliance.
(Default = 1 Watt /+30 dBm)
Password—Used for remote access and some Management System
features. (Default = admin)
Step 5 – Connect the Data Equipment
Connect the data equipment to data port(s):
•LAN—10BaseT Ethernet-compatible equipment:
Ethernet Hub (Straight-Through Cable); Ethernet Node (Crossover)
•COM2—Serial, RS/EIA-232 compatible equipment
•COM1—Management System (Default); Serial (Alternate)
The Management System can be accessed through the COM1 Port using a terminal session on a PC. The basic items listed below,
along with many other parameters & tools can be accessed through this method. HTTP, Telnet access, and changing some parameters
are controlled by password.
BASIC CONFIGURATION DEFAULTS
Step 6 – Check for Normal Operation
•Observe the transceiver LED status panel for the proper indications. In a normally operating system, the following LED indications
will be seen within 30 seconds of power-up:
PWR—Lights continuously LAN—On or blinks intermittently LINK— On or blinks intermittently (Remotes: if associated)
• Use PING command to test basic data link integrity between Access Point and Remotes.
• If the PING command is successful, connect the RTU/data equipment to the data port and verify normal operation.
•If the LINK LED on Remotes is not on after 20 to 30 seconds, the unit has failed to associate with the Access Point. It may be
necessary to reposition or redirect the radio’s antenna for better reception/signal strength.
•Check connected data equipment for normal operation
TYPICAL INSTALLATION
Detailed instructions for setting transceiver parameters are contained in Section 3 of this manual.
VALUES/RANGE
• Remote
•Access Point
•1–8 alphanumeric characters
•Case-sensitive; can be mixed case
• 1–16 alphanumeric characters
• Case-sensitive; can be mixed case
Contact your Network Administrator
20–30 dBm @ 50Ω (0.1–1.0 Watt)
DEFAULT
Remote
admin
(lower case)
"Not Programmed"
192.168.1.1
+30 dBm (1.0 Watt)
ITEM MGT SYSTEM MENU
Device Mode Network Configuration
Unit Password Device Information
Network Name Network Configuration
IP Address Network Configuration
RF Output Power Radio Configuration
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide i
Contents
1
PRODUCT OVERVIEW AND APPLICATIONS ......... 1
1.1 PRODUCT DESCRIPTION............................................................................................. 3
1.1.1 Model Offerings ................................................................................................................... 5
1.2 APPLICATIONS ..............................................................................................................5
1.2.1 Wireless LAN ....................................................................................................................... 5
1.2.2 Point-to-Point LAN Extension .............................................................................................. 6
1.2.3 Backhaul for Serial Radio Networks .................................................................................... 6
1.2.4 Multiple Protocols and/or Services ...................................................................................... 7
1.2.5 Wireless LAN with Mixed Services ...................................................................................... 8
1.2.6 Upgrading Older Wireless Network with Serial Interfaces ................................................... 9
1.2.7 High-Speed Mobile Data ................................................................................................... 10
1.3 NETWORK DESIGN CONSIDERATIONS.................................................................... 10
1.3.1 Extending Network Coverage with Repeaters ................................................................... 10
1.3.2 Protected Network Operation using Multiple Access Points .............................................. 12
1.3.3 Collocating Multiple Radio Networks ................................................................................. 13
1.4 MDS SECURITY SUITE ............................................................................................... 14
1.4.1 Early Warning via SNMP Traps ......................................................................................... 15
1.5 ACCESSORIES ............................................................................................................ 15
2
TABLETOP EVALUATION AND TEST SETUP ....... 17
2.1 OVERVIEW................................................................................................................... 19
2.2 STEP 1—INSTALL THE ANTENNA CABLING............................................................. 19
2.3 STEP 2—MEASURE & CONNECT THE PRIMARY POWER ...................................... 20
2.4 STEP 3—CONNECT PC TO THE TRANSCEIVER ...................................................... 20
2.5 STEP 4—REVIEW TRANSCEIVER CONFIGURATION............................................... 21
2.5.1 Getting Started .................................................................................................................. 21
2.5.2 Procedure .......................................................................................................................... 21
2.5.3 Basic Configuration Defaults ............................................................................................. 21
ii MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
2.6 STEP 5—CONNECT LAN AND/OR SERIAL EQUIPMENT ......................................... 22
2.7 STEP 6—CHECK FOR NORMAL OPERATION........................................................... 23
3
EMBEDDED MANAGEMENT SYSTEM ................... 25
3.1 MS INTRODUCTION .................................................................................................... 27
3.1.1 Differences in the User Interfaces .....................................................................................27
3.2 ACCESSING THE MENU SYSTEM ............................................................................. 29
3.2.1 Methods of Control ............................................................................................................ 30
3.2.2 PC Connection & Log In Procedures ................................................................................ 30
3.2.3 Navigating the Menus ........................................................................................................ 34
3.3 BASIC DEVICE INFORMATION ................................................................................... 36
3.3.1 Starting Information Screen ............................................................................................... 36
3.3.2 Main Menu ......................................................................................................................... 37
3.3.3 Configuring Basic Device Parameters ............................................................................... 38
3.4 CONFIGURING NETWORK PARAMETERS................................................................ 40
3.4.1 Network Configuration Menu ............................................................................................. 40
3.4.2 IP Address Configuration Menu ......................................................................................... 42
3.4.3 Ethernet Port Configuration Menu ..................................................................................... 43
3.4.4 DHCP Server Configuration .............................................................................................. 44
3.4.5 SNMP Agent Configuration ............................................................................................... 46
3.5 RADIO CONFIGURATION............................................................................................ 48
3.5.1 Radio Configuration Menu ............................................................................................... 48
3.5.2 Mobile Data Configuration ................................................................................................. 54
3.6 CONFIGURING THE SERIAL INTERFACES ............................................................... 56
3.6.1 Overview ............................................................................................................................ 56
3.6.2 Serial Data Port Configuration Menu ................................................................................. 59
3.6.3 Configuring for UDP Mode ................................................................................................ 60
3.6.4 Configuring for TCP Mode ................................................................................................. 64
3.6.5 Configuring for PPP Mode ................................................................................................. 66
3.6.6 IP-to-Serial Application Example .......................................................................................67
3.6.7 Point-to-Point Serial-to-Serial Application Example ........................................................... 68
3.6.8 Point-to-Multipoint Serial-to-Serial Application Example ................................................... 69
3.6.9 Mixed Modes ..................................................................................................................... 71
3.7 SECURITY CONFIGURATION ..................................................................................... 73
3.7.1 Approved Remotes/Access Points List Menu .................................................................... 75
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide iii
3.8 PERFORMANCE VERIFICATION ................................................................................ 76
3.8.1 Performance Information Menu ......................................................................................... 76
3.8.2 Network Performance Notes ............................................................................................. 87
3.9 MAINTENANCE............................................................................................................ 91
3.9.1 Reprogramming Menu ....................................................................................................... 92
3.9.2 Configuration Scripts Menu ............................................................................................... 97
3.9.3 Authorization Keys Menu ................................................................................................. 105
3.9.4 Auto-Upgrade/Remote-Reboot Menu .............................................................................. 106
3.9.5 Radio Test Menu .............................................................................................................. 107
3.9.6 Ping Utility Menu .............................................................................................................. 108
3.9.7 Reset to Factory Defaults ................................................................................................ 108
3.9.8 Resetting the Password ................................................................................................... 108
4
TROUBLESHOOTING & RADIO
MEASUREMENTS ...................................................113
4.1 TROUBLESHOOTING ................................................................................................ 113
4.1.1 Interpreting the Front Panel LEDs ................................................................................... 113
4.1.2 Troubleshooting Using the Embedded Management System .......................................... 114
4.1.3 Using Logged Operation Events ...................................................................................... 118
4.1.4 Alarm Conditions ............................................................................................................. 118
4.1.5 Correcting Alarm Conditions ........................................................................................... 120
4.1.6 Logged Events ................................................................................................................. 121
4.2 RADIO (RF) MEASUREMENTS ................................................................................. 123
4.2.1 Antenna System SWR and Transmitter Power Output .................................................... 124
4.2.2 Antenna Aiming ............................................................................................................... 125
5
PLANNING A RADIO NETWORK ......................... 129
5.1 INSTALLATION PLANNING........................................................................................ 129
5.1.1 General Requirements .................................................................................................... 129
5.1.2 Site Selection .................................................................................................................. 131
5.1.3 Terrain and Signal Strength ............................................................................................. 131
5.1.4 Antenna & Feedline Selection ......................................................................................... 132
5.1.5 How Much Output Power Can be Used? ......................................................................... 135
5.1.6 Conducting a Site Survey ................................................................................................ 135
5.1.7 A Word About Radio Interference .................................................................................... 136
5.2 dBm-WATTS-VOLTS CONVERSION CHART ............................................................ 139
iv MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
6
TECHNICAL REFERENCE ................................... 141
6.1 DATA INTERFACE CONNECTORS............................................................................ 143
6.1.1 LAN Port .......................................................................................................................... 143
6.1.2 COM1 Port ....................................................................................................................... 144
6.1.3 COM2 Port ....................................................................................................................... 144
6.2 FUSE REPLACEMENT PROCEDURE....................................................................... 145
6.3 TECHNICAL SPECIFICATIONS ................................................................................. 146
6.4 CHANNEL HOP TABLE .............................................................................................. 149
6.5 SNMP USAGE NOTES............................................................................................... 151
6.5.1 Overview .......................................................................................................................... 151
7
GLOSSARY OF TERMS & ABBREVIATIONS ...... 155
Copyright Notice
This publication is protected by U.S.A. copyright law. Copyright 2005, Microwave Data Systems,
Inc. All rights reserved.
ISO 9001 Registration
Microwave Data Systems adheres to the internationally-accepted ISO 9001 quality system stan-
dard.
To our Customers
We appreciate your patronage. You are our business. We promise to serve and anticipate your
needs. We will strive to give you solutions that are cost effective, innovative, reliable and of the
highest quality possible. We promise to build a relationship that is forthright and ethical, one that
builds confidence and trust.
What Products are Covered in this Manual?
This manual covers two members of the MDS iNET Transceiver Series, both of which are designed
to be operated under the FCC s Part 15 license-free rules. The standard iNET radio is a Frequency
Hopping Spread Spectrum (FHSS) transceiver that operates at data speeds of 256 and 512 kbps.
The iNET II is a similar design, but it does not utilize frequency hopping technology. It operates
under the Digital Transmission System (DTS) provisions of Part 15 and can operate at data speeds
of 512 or 1024 kbps. Operational differences between these two models are identified, as neces-
sary, in this manual.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide v
Other MDS
i
NET 900 Series Documentation
Installation Guide
The associated MDS
i
NET 900 Series Installation Guide, P/N 05-2873A01, is
provided with the transceiver and is limited to essential information needed for installers. The
installation guide assumes some guidance to installers will be provided by the readers of this
manual. This includes such things as antenna selection, radio communication site survey tools and
techniques, and network design.
Related Materials on the Internet
Data sheets, frequently asked questions, case studies, applica-
tion notes, firmware upgrades and other updated information is available on the MDS Web site at
www.microwavedata.com.
About Microwave Data Systems Inc.
Almost two decades ago, MDS began building radios for business-critical applications. Since then,
we ve installed more than 500,000 radios in over 110 countries. To succeed, we overcame impass-
able terrain, brutal operating conditions and disparate, complex network configurations. We also
became experts in wireless communication standards and system applications worldwide. The
result of our efforts is that today, thousands of utilities around the world rely on MDS-based wire-
less networks to manage their most critical assets.
The majority of MDS radios deployed since 1985 are still installed and performing within our cus-
tomers’ wireless networks. That s because we design and manufacture our products in-house,
according to ISO 9001 which allows us to control and meet stringent global quality standards.
Thanks to our durable products and comprehensive solutions, MDS is the wireless leader in indus-
trial automation including oil and gas production and transportation, water/wastewater treat-
ment, supply and transportation, electric transmission and distribution and many other utility
applications. MDS is also at the forefront of wireless communications for private and public infra-
structure and online transaction processing. Now is an exciting time for MDS and our customers
as we look forward to further demonstrating our abilities in new and emerging markets.
As your wireless needs change you can continue to expect more from MDS. We’ll always put the
performance of your network above all. Visit us at www.microwavedata.com for more informa-
tion.
OPERATIONAL & SAFETY NOTICES
UL/CSA Notice
This product is available for use in Class 1, Division 2, Groups A, B, C & D Hazardous Locations. Such locations are
defined in Article 500 of the National Fire Protection Association (NFPA) publication
NFPA 70
, otherwise known as
the National Electrical Code.
The transceiver has been recognized for use in these hazardous locations by two independent agencies Underwriters
Laboratories (UL) and the Canadian Standards Association (CSA). The UL certification for the transceiver is as a Rec-
ognized Component for use in these hazardous locations, in accordance with UL Standard 1604. The CSA Certifica-
tion is in accordance with CSA STD C22.2 No. 213-M1987.
Professional installation required. The radio equipment described in this guide emits radio
frequency energy. Although the power level is low, the concentrated energy from a direc-
tional antenna may pose a health hazard. Do not allow people to come closer than 23 cm
(9 inches) to the antenna when the transmitter is operating in indoor or outdoor environ-
ments. More information on RF exposure is on the Internet at
www.fcc.gov/oet/info/documents/bulletins
.
RF Exposure
vi MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
UL/CSA Conditions of Approval: The transceiver is not acceptable as a stand-alone unit for use in the hazardous
locations described above. It must either be mounted within another piece of equipment which is certified for
hazardous locations, or installed within guidelines, or conditions of approval, as set forth by the approving agencies.
These conditions of approval are as follows:
The transceiver must be mounted within a separate enclosure which is suitable for the intended application.
The antenna feedline, DC power cable and interface cable must be routed through conduit in accordance with the
National Electrical Code.
Installation, operation and maintenance of the transceiver should be in accordance with the transceiver’s installation
manual, and the National Electrical Code.
Tampering or replacement with non-factory components may adversely affect the safe use of the transceiver in haz-
ardous locations, and may void the approval.
A power connector with screw-type retaining screws as supplied by MDS must be used.
Do not disconnect equipment unless power has been switched off or the area is known to
be non-hazardous.
Refer to Articles 500 through 502 of the National Electrical Code (NFPA 70) for further
information on hazardous locations and approved Division 2 wiring methods.
FCC Part 15 Notices
The transceiver series complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation. This device is specifically designed to be used under Section 15.247
of the FCC Rules and Regulations. Any unauthorized modification or changes to this device without the express
approval of Microwave Data Systems may void the user s authority to operate this device. Furthermore, the iNET
Series is intended to be used only when installed in accordance with the instructions outlined in this manual. Failure
to comply with these instructions may also void the user s authority to operate this device.
Part 15 rules also require that the Effective Isotropic Radiated Power (EIRP) from an MDS iNET Series installation
not exceed 36 dBm. Refer to
Antenna & Feedline Selection
on Page 132 for more information.
Industry Canada RSS Notices
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may cause undesired operation of the device.
To reduce potential radio interference to other users, the antenna type and its gain should be chosen so that the Equiv-
alent Isotropic Radiated Power (EIRP) is not more than that permitted for successful communication.
This device as been designed to operate with the antennas listed below, and having a maximum gain of 12 dB.
Antennas not included in this list or having a gain greater than 12 dB are strictly prohibited for use with this device.
The required antenna impedance is 50 ohms. Refer to Table 5-2 on Page 134 for a list of antennas acceptable for use
with this transceiver.
Manual Revision and Accuracy
While every reasonable effort has been made to ensure the accuracy of this manual, product improvements may result
in minor differences between the manual and the product shipped to you. If you have additional questions or need an
exact specification for a product, please contact our Customer Service Team using the information at the back of this
guide. In addition, manual updates can often be found on the MDS Web site at www.microwavedata.com.
Environmental Information
The manufacture of this equipment has required the extraction and use of natural resources. Improper disposal may
contaminate the environment and present a health risk due to hazardous substances contained within. To avoid dissem-
ination of these substances into our environment, and to limit the demand on natural resources, we encourage you to
use the appropriate recycling systems for disposal. These systems will reuse or recycle most of the materials found in
this equipment in a sound way. Please contact MDS or your supplier for more information on the proper disposal of
this equipment.
EXPLOSION
HAZARD!
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 1
1
PRODUCT OVERVIEW
AND APPLICATIONS
1 Chapter Counter Reset Paragraph
Contents
1.1 PRODUCT DESCRIPTION ..................................................... 3
1.1.1 Model Offerings ........................................................................ 5
1.2 APPLICATIONS ....................................................................... 5
1.2.1 Wireless LAN ........................................................................... 5
1.2.2 Point-to-Point LAN Extension ................................................... 6
1.2.3 Backhaul for Serial Radio Networks ......................................... 6
1.2.4 Multiple Protocols and/or Services ........................................... 7
1.2.5 Wireless LAN with Mixed Services ........................................... 8
1.2.6 Upgrading Older Wireless Network with
Serial Interfaces .................................................................................. 9
1.2.7 High-Speed Mobile Data .......................................................... 10
1.3 NETWORK DESIGN CONSIDERATIONS............................... 10
1.3.1 Extending Network Coverage with Repeaters ......................... 10
1.3.2 Protected Network Operation using Multiple Access Points .... 12
1.3.3 Collocating Multiple Radio Networks ........................................ 13
1.4 MDS SECURITY SUITE.......................................................... 14
1.4.1 Early Warning via SNMP Traps ................................................ 15
1.5 ACCESSORIES....................................................................... 15
2 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 3
1.1 PRODUCT DESCRIPTION
The MDS iNET 900 transceiver provides an easy-to-install wireless
solution for local area network (LAN) service with plug-and-play hard-
ware and long range operation. It supports both Ethernet and serial data
interface options at over-the-air data speeds of up to 512 kbps for iNET
and 1024 kbps for iNET II).
NOTE: For information on the MDS iNET 900 ENI, which provides
expanded gateway and protocol conversion capabilities not
found in the MDS iNET 900 (DF1 to EIP, and MODBUS to
MODBUS TCP conversions), refer to the MDS iNET/ENI
Supplement (05-4131A01).
Invisible place holder
Figure 1-1. The MDS iNET 900 Transceiver
Rugged Packaging The transceiver is housed in a compact and rugged cast-aluminum case
that need only be protected from direct exposure to the weather. It con-
tains a single printed circuit board with all necessary components for
radio operation and data communications. The only user-serviceable
component inside the case is a fuse on the DC power input line.
Simple Installation Most installations employ an omni-directional antenna at the Access
Point (AP) location and a directional antenna at each Remote unit. The
antenna is a vital link in the system and must be chosen and installed
correctly. Consult INSTALLATION PLANNING on Page 129 for guid-
ance on choosing suitable installation sites and antennas.
For basic services, simply connect an antenna, connect your Ethernet
LAN to the transceiver’s LAN port, apply primary power, set a few oper-
ating parameters, and you are done. No license is required for operation
in the U.S.A., Canada, and many other countries. Check requirements
for your region before placing the transceiver in service.
Secure Operation Data network security is a vital issue in today's wireless world. The
MDS iNET 900 Series design provides multiple tools to help you build
a network that minimizes the risk of eavesdropping and unauthorized
access. Some are inherent in the radio's operation, such as the use of
spread-spectrum transmissions; others include data encryption, en-
4 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
abling/disabling remote access channels, and password protection.
Remember, security is not a one-step process that can simply be turned
on and forgotten. It must be practiced and enforced at multiple levels,
24 hours-a-day and 7 days-a-week. See “MDS SECURITY SUITE” on
Page 14 for more information about the transceiver’s security tools.
Robust Radio
Operation The transceiver is designed for frequency-hopping spread-spectrum
operation (DTS for iNET II) in the license-free 900 MHz Industrial, Sci-
entific, and Medical (ISM) band. It can provide reliable communica-
tions at distances up to 25 miles (40 km) over favorable terrain, even in
the presence of weak signals or interference.
Flexible Services Users with a mixture of equipment having Ethernet and serial data inter-
faces can choose to use one or two of the user-configurable serial ports
through the use of a Remote Dual Gateway. This flexibility allows the
transceiver to provide services in data networks that are being migrated
from legacy serial/EIA-232-based hardware to the faster and more
easily interfaced Ethernet world.
Flexible
Management Configuration, commissioning, troubleshooting and other maintenance
activities can be done locally or remotely. Four different modes of
access are available: local RS-232 console, local or remote IP access
(via Telnet), web browser, and SNMP (v1/v2/v3). The text-based inter-
face (RS-232 console and Telnet) is implemented in the form of
easy-to-follow menus, and the terminal server configuration includes a
wizard to help you set up the units correctly.
Transceiver
Features The transceiver’s design makes the installation and configuration easy,
while allowing for changes in the future.
• Long Range—Up to 25 miles (40 km) in line-of-sight condi-
tions. Repeater stations may be used to extend the operational
range. (Refer to TECHNICAL SPECIFICATIONS on Page 146
for more detailed information on range.)
• Industrial-Grade Product—Extended temperature range for
trouble-free operation in extreme environments
•Robust Radio Communications—Designed to operate in dense,
high-interference environments
• Robust Network Security—Prevents common attack schemes
and hardware from gaining access or control of network. Com-
mon attack events logged and reported by alarms.
• High Speed—512 kbps is 50-times faster than 9.6 kbps radios
• Plug-and-Play Connectivity—Ethernet bridge configuration
option requires minimal setup
• Serial Ports—Gateway for serial-based equipment to IP/Ether-
net networks with embedded terminal server. Site-to-site con-
figurations are also possible.
• Single hardware package provides configuration as Access
Point or Remote
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 5
1.1.1 Model Offerings
The transceiver comes in two primary models—Access Point and
Remote. Three types of Remote Gateways are available—the Ethernet
Bridge, the Serial Gateway, and the Dual Gateway supporting both
IP/Ethernet and serial services. Table 1-1 summaries the different inter-
face abilities for each type.
A unit can be configured by the owner to operate as an Access Point or
as a Remote with some restrictions. Only the Dual Gateway Remote
units can be reconfigured as an Access Point. Ethernet Bridge and a
Serial Gateway Remotes cannot be reconfigured as Access Point unless
they are first upgraded to Dual Gateway type. This is accomplished with
an “Authorization Key” purchased from the factory. Each one of these
individual software keys is associated with the serial number of the cor-
responding unit.
1.2 APPLICATIONS
The following sections provide illustrations of typical transceiver instal-
lations. This is meant as an overview only. It is recommended that a net-
work manager be involved in all installation planning activities.
1.2.1 Wireless LAN
The wireless LAN is the most common application of the transceiver. It
consists of a central control station (Access Point) and one or more asso-
ciated Remote units, as shown in Figure 1-2 on Page 6. A LAN provides
communications between a central WAN/LAN and remote Ethernet
segments. The operation of the radio system is transparent to the com-
puter equipment connected to the transceiver.
Table 1-1. Transceiver Models and Data Interface Services
Model Type LAN1COM11COM2
Access Point3N/A Yes Yes Yes
Remote… Ethernet
Bridge2
Yes No No
Serial
Gateway2
No Yes Yes
Dual Gateway3Yes Yes Yes
NOTES
1. Provides access to the embedded Management System on all units.
2. Can be upgraded to Dual Gateway with an Authorization Key.
3. Can be configured as an Access Point or Dual Gateway through the
embedded Management System.
4. In addition, the iNET II is available. This model operates at 512/1024
kbps under the FCC DTS rules, which allow wider modulation band-
widths to be employed.
6 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
The Access Point is positioned at a location from which it can commu-
nicate with all of the Remote units in the system. Commonly, this is a
high location on top of a building or communications tower. Messages
are exchanged at the Ethernet level. This includes all types of IP traffic.
A Remote transceiver can only talk over-the-air to an Access Point unit
(AP). Peer-to-peer communications between Remotes can only take
place indirectly via the AP. In the same fashion, an AP can only talk
over-the-air to associated Remote units. Exception: Two APs can com-
municate with each other “off-the-air” through their Ethernet connectors
using a common LAN/WAN.
Invisible place holder
Figure 1-2. Typical Wireless LAN
1.2.2 Point-to-Point LAN Extension
A point-to-point configuration (Figure 1-3) is a simple arrangement
consisting of an Access Point and a Remote unit. This provides a com-
munications link for the transfer of data between two locations.
Invisible place holder
Figure 1-3. Typical Point-to-Point Link
1.2.3 Backhaul for Serial Radio Networks
One of the primary design features of the transceiver is to provide a path
for serial devices to migrate to IP/Ethernet. Many radio networks in
operation today still rely on serial networks at data rates of 9600 bps or
less. These networks can use the transceiver as a means to continue
using the serial service, while allowing the rest of the infrastructure to
migrate to an IP format.
Remote
Remote
Access Point
Remote
Remote LAN
LAN
WAN/LAN
LAN
LAN
LAN/WAN
Access Point Remote
LAN
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 7
A Remote transceiver using one serial port for the data stream, and the
other for network-wide diagnostics can support operational radio net-
works built with earlier MDS radios, such as MDS x790/x710, MDS
x810 and others. In the case of these existing radios, where a single port
is used for data and diagnostics, the capabilities are doubled. The data
streams are delivered to an IP socket in an application, or in serial format
using the Access Point.
Invisible place holder
Figure 1-4. Backhaul Network
1.2.4 Multiple Protocols and/or Services
Prior to the MDS 900 Series, two radios were often used to service two
different types of devices (typically connected to different SCADA
hosts). An iNET 900 radio provides this functionality with a single
remote radio. Each of the two serial ports can be connected via IP to dif-
ferent SCADA hosts, transporting different (or the same) protocols.
Both data streams are completely independent and the transceiver pro-
vides seamless simultaneous operation as shown in Figure 1-5 on
Page 8.
Data
Data
MDS 4790
Master
MDS 9790
Master
MDS 9810
Master
Diagnostics
Data
Diagnostics
Diagnostics
MDS 4710 Remote
NMS Control
Point
SCADA Host
Modbus/IP
HUB Access Point
MDS 4710 Remote
MDS 9710 Remote
MDS 9710 Remote
MDS 9810 Remote
MDS 9810 Remote
Remote Serial
Remote Serial
Remote Serial
NETWORK
ROUTER
ROUTER
Serial
Device
Serial
Device
Serial
Device
Serial
Device
Serial
Device
Serial
Device
8 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Invisible place holder
Figure 1-5. Multiple Protocol Network
By using a single radio, the cost of deployment is cut in half. Beyond
requiring only one radio instead of two, the biggest cost reduction comes
from using half of the required infrastructure at the remote site: one
antenna, one feedline, one lightning protector and ancillary hardware.
Other cost reductions come from the system as a whole, such as reduced
management requirements. And above all, the potential for future appli-
cations that run over Ethernet and IP, such as video for remote surveil-
lance.
1.2.5 Wireless LAN with Mixed Services
The transceiver is an excellent solution for a long-range industrial wire-
less LAN. It offers several advantages over commercial solutions—pri-
marily improved performance over extended distances. The rugged
construction of the radio and its extended temperature range make it an
ideal solution even in harsh locations. In extreme environments, a
simple NEMA enclosure is sufficient to house the unit.
The transceiver trades higher speed for longer range. Commercial
802.11b solutions are designed to provide service to relatively small
areas such as offices, warehouses and homes. They provide high data
rates but have limited range. The iNET 900 transmits at a higher power
level, uses a different frequency band, has higher sensitivity, and a nar-
rower channel to concentrate the radio energy and reach farther dis-
tances. It is designed for industrial operation from the ground up.
IP-based devices that may be used with the transceiver include a new
breed of more powerful Remote Terminal Units (RTUs) and Program-
mable Logic Controllers (PLCs). These, as well as other devices, may
be used in applications ranging from SCADA/telemetry monitoring,
web-based video, security monitoring, and voice over IP. Figure 1-6
shows a typical wireless IP network.
NETview SCADA Host
Total Flow
Access Point
Remote Serial
Remote Serial
SCADA Host
Modbus/IP
Remote Serial
Access Point
RTU
Flow Meter
EIA-232
EIA-232
EIA-232
EIA-232
EIA-232
EIA-232
ROUTER
HUB
Serial
Device
Serial
Device
Serial
Device
Serial
Device
HUB
HUB
HUB
WAN
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 9
Invisible place holder
Figure 1-6. Extended-Range LAN with Mixed Applications
1.2.6 Upgrading Older Wireless Network with
Serial Interfaces
Millions of wireless data products have been sold in the last two decades
for licensed and license-free operation, many of them manufactured by
Microwave Data Systems. There are several ways that these systems can
benefit from incorporating MDS iNET 900 equipment. The chief advan-
tages are interface flexibility (serial and Ethernet in one unit), and higher
data throughput. By taking advantage of its built-in serial and Ethernet
interfaces, the transceiver is well suited to replace leased lines, dial-up
lines, or existing 900 MHz data transceivers.
Replacing Legacy Wireless Products
In most cases, legacy radio transceivers supporting serial-interface
equipment can be replaced with iNET 900 transceivers. Legacy equip-
ment can be connected to the transceiver through the COM1 or COM2
port with a DB-25 to DB-9 cable wired for EIA-232 signaling. The
COM2 port supports all standard EIA-232 signaling and acts as a
data-terminal equipment device (DTE).
NOTE: Several previous MDS-brand products had non-standard
signal lines on their interface connectors (for example, to
control sleep functions and alarm lines). These special func-
tions are not provided nor supported by the iNET transceiver.
Consult equipment manuals for complete pinout information.
Supplement legacy wireless network with IP services
The MDS iNET 900 Dual Gateway model can support up to two serial
devices and one Ethernet connection at the same time. The serial inter-
faces (COM1 and COM2) operate in two different modes: Connection-
less UDP and connection-orientated TCP.
NMS Control
Point
SCADA Host
Modbus/IP
Access Point
Remote Bridge
Printer
Remote Bridge
IP Camera
IP/Ethernet Device
IP/Ethernet Device
IP/Ethernet Device
10 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
In the UDP mode, the transceiver supports point-to-multipoint
serial-port to serial-port connectivity. In the TCP mode, it supports
point-to-point Ethernet/IP to serial port connectivity.
For further details on the transceiver’s Serial Gateway interface modes,
see “CONFIGURING THE SERIAL INTERFACES” on Page 56.
1.2.7 High-Speed Mobile Data
The iNET radios support high-speed data communications in a mobile
environment. Remote radios roam between different access points, pro-
viding seamless transitions and continuous coverage. For additional
information on configuring a mobile network, refer to Mobile Data
Configuration on Page 54.
1.3 NETWORK DESIGN
CONSIDERATIONS
1.3.1 Extending Network Coverage with Repeaters
What is a Repeater System?
A repeater works by re-transmitting data from outlying remote sites to
the Access Point and vice-versa. It introduces some additional
end-to-end transmission delay but provides longer-range connectivity.
In some geographical areas, obstacles can make communications diffi-
cult. These obstacles are commonly large buildings, hills, or dense
foliage. These obstacles can often be overcome with a repeater station.
Option 1—Using two transceivers to form a repeater station
(back-to-back repeater)
Although the range between transceivers can be up to 40 km (25 miles)
over favorable terrain, it is possible to extend the range considerably by
connecting two units together at one site in a “back-to-back” fashion to
form a repeater, as shown in Figure 1-7. This arrangement should be
used whenever the objective is to utilize the maximum range between
stations. In this case, using high-gain Yagi antennas at each location will
provide more reliable communications than their counterparts—omni-
directional antennas.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 11
Invisible place holder
Figure 1-7. Typical LAN with a Repeater Link
Overview Two transceivers may be connected “back-to-back” through the LAN
Ports to form a repeater station. (The cable must be a “cross-over”
Ethernet cable for this to work). This configuration is sometimes
required in a network that includes a distant Remote that would other-
wise be unable to communicate directly with the Access Point station
due to distance or terrain.
The geographic location of a repeater station is especially important. A
site must be chosen that allows good communication with both the
Access Point and the outlying Remote site. This is often on top of a hill,
building, or other elevated terrain from which both sites can be “seen”
by the repeater station antennas. A detailed discussion on the effects of
terrain is given in Section 5.1.2, Site Selection (beginning on Page 131).
The following paragraphs contain specific requirements for repeater
systems.
Antennas Two antennas are required at this type of repeater station—one for each
radio. Measures must be taken to minimize the chance of interference
between these antennas. One effective technique for limiting interfer-
ence is to employ vertical separation. In this arrangement, assuming
both are vertically polarized, one antenna is mounted directly over the
other, separated by at least 10 feet (3 Meters). This takes advantage of
the minimal radiation exhibited by most antennas directly above and
below their driven elements.
Another interference reduction technique is to cross-polarize the
repeater antennas. If one antenna is mounted for polarization in the ver-
tical plane, and the other in the horizontal plane, an additional 20 dB of
attenuation can be achieved. (Remember that the corresponding stations
should use the same antenna orientation when cross-polarization is
used.)
Network Name The two radios that are wired together at the repeater site must have dif-
ferent network names. To set or view the network names, see “STEP 3—
CONNECT PC TO THE TRANSCEIVER” on Page 20 for details.
Access Point
Remote
Remote
Remote
Remote
Access
Point
LAN/WAN
REPEATER
Crossover Cable
LAN
LAN
LAN
Ethernet
POINT-TO-POINT LINK
12 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Option 2—Using the AP as a Store-and-Forward Packet
Repeater
A wireless network can be extended through the use of an alternate
arrangement using the Access Point as a repeater to re-transmit the sig-
nals of all stations in the network. The repeater is a standard transceiver
configured as an Access Point, and operating in Store and Forward
mode. (See Figure 1-8.)
Invisible place holder
Figure 1-8. Typical network with store-and-forward repeater
As with the conventional repeater described in Option 1 above, the loca-
tion of a store and forward repeater is also important. A site must be
chosen that allows good communication with both the Access Point and
the outlying Remote site. This can be on the top of a hill, building, or
other elevated terrain from which all sites can be “seen” by the repeater
station antenna. A detailed discussion on the effects of terrain is given
in Section 5.1.2, Site Selection (beginning on Page 131)
1.3.2 Protected Network Operation using Multiple
Access Points
Although MDS transceivers have a very robust design and have under-
gone intensive testing before being shipped, it is possible for isolated
failures to occur. In mission-critical applications, down time can be vir-
tually eliminated by using some, or all, of the following configurations:
In a point-to-multipoint scenario, the Access Point services multiple
remotes. A problem in the Access Point will have an effect on all
remotes, since none will have access to the network. When operation of
the network does not tolerate any down time, it is possible to set up a
protected configuration for the Access Point to greatly reduce the possi-
bility of this occurrence.
Two or more Access Points can be configured with the same Network
Name and kept active simultaneously, each with its own independent
antenna. In this scenario, Remotes will associate with either one of the
available Access Points. In case of a failure of one of the AP’s the
Remotes will quickly associate with another of the remaining Access
Points re-establishing connectivity to the end devices.
Remote
Remote
Remote
Remote
Access Point
LAN/WAN
REPEATER
LAN
LAN
LAN
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 13
The Access Points are unaware of the existence of the other AP’s.
Because the hopping algorithm uses both the Network Name and the
Wireless MAC address of the AP to generate the hopping pattern, mul-
tiple AP’s can coexist—even if they use the same network name. The
collocated AP’s will be using different hopping patterns and frequencies
the great majority of the time. Although some data collisions will occur,
the wireless-MAC is built to tolerate and recover from such occurrences
with minimal degradation.
1.3.3 Collocating Multiple Radio Networks
Many networks can operate in relatively close physical proximity to one
another provided reasonable measures are taken to assure the radio
signal of one Access Point is not directed at the antenna of the second
Access Point.
The Network Name and the association process
The Network Name is the foundation for building individual radio net-
works. It is part of a beacon signal broadcast by the Access Point (AP)
to any Remote units with the same Network Name. Remotes that join the
network are referred to as being “associated” with the Access Point unit.
Multiple APs with the same Network Name should be avoided unless a
redundant system is being deployed. Using the same Network Name in
multiple APs may result in Remotes associating with undesired APs and
preventing data exchange from occurring.
The use of a different Network Name does not guarantee an interfer-
ence-free system. It does however, assure that only data destined for a
unique network is passed through to that network.
Co-Location for
Multiple Networks It may be desirable to co-locate Access Points at one location to take
advantage of an excellent or premium location that can serve two inde-
pendent networks. Each network should have unique Network Name
and each AP unit’s antenna should be provided as much vertical separa-
tion as is practical to minimize RFI.
NOTE: All transceivers are shipped with the Network Name set to
“Not Programmed.” The Network Name must be programmed
in order to pass data and begin normal operations.
Can radio frequency interference (RFI) disrupt my wireless
network?
When multiple radio networks operate in close physical proximity to
other wireless networks, individual units may not operate reliably under
weak signal conditions and may be influenced by strong radio signals in
adjacent bands. This radio frequency interference cannot be predicted
with certainty, and can only be determined by experimentation. If you
need to co-locate two units, start by using the largest possible vertical
14 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
antenna separation between the two AP antennas on the same support
structure. If that does not work, consult with your factory representative
about other techniques for controlling radio frequency interference
between the radios. (See “A Word About Radio Interference” on
Page 136 for more details.)
1.4 MDS SECURITY SUITE
Today the operation and management of an enterprise is becoming
increasing dependent on electronic information flow. An accompanying
concern becomes the security of the communication infrastructure and
the security of the data itself.
The MDS iNET 900 transceiver is capable of dealing with many
common security issues. Table 1-2 profiles security risks and how the
transceiver provides a solution for minimizing vulnerability.
Table 1-2. Security Risk Management
Security Vulnerability MDS iNET 900 Solution
Unauthorized access to the backbone
network through a foreign remote radio • Approved Remotes List
Only those remotes included in the
AP list will associate
“Rogue” AP, where a foreign AP takes
control of some or all remote radios and
thus remote devices
• Approved AP List
A remote will only associate to those
AP included in its local authorized
list of AP
Dictionary attacks, where a hacker runs a
program that sequentially tries to break a
password.
• Failed-login lockdown
After 3 tries, the transceiver ignores
login requests for 5 minutes. Critical
event reports (traps) are generated
as well.
Denial of service, where Remote radios
could be reconfigured with bad
parameters bringing the network down.
•Remote login
•Local console login
•Disabled HTTP & Telnet to allow
only local management services
Airsnort and other war-driving hackers in
parking lots, etc. •900 MHz FHSS for iNET (DTS for
iNET II) does not talk over the air
with standard 802.11b cards
•The transceiver cannot be put in a
promiscuous mode
•Proprietary data framing
Eavesdropping, intercepting messages •128-bit encryption
Key cracking • Automatic Rotating Key algorithm
Replaying messages •128-bit encryption with rotating keys
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 15
1.4.1 Early Warning via SNMP Traps
In addition to the operative tools and techniques, the transceiver can
send SNMP traps (alarms) to a network management systems when cer-
tain potentially suspicious activities or events occur. The alarms
include:
• Unauthorized AP MAC address detected at Remote
• Unauthorized Remote MAC address detected at AP
• Login attempt limit exceeded
(Accessed via: Telnet, HTTP, or local)
• Successful login/logout
(Accessed via: Telnet, HTTP, or local)
1.5 ACCESSORIES
The transceiver can be used with one or more of the accessories listed in
Table 1-3. Contact the factory for ordering details.
Unprotected access to configuration via
SNMPv1 •Implement SNMPv3 secure
operation
Intrusion detection •Provides early warning via SNMP
through critical event reports
(unauthorized, logging attempts,
etc.)
Table 1-2. Security Risk Management
Security Vulnerability MDS iNET 900 Solution
Table 1-3. Accessories
Accessory Description MDS Part No.
AC Power
Adapter Kit
A small power supply module designed for
continuous service. UL approved. Input:
120/220; Output: 13.8 Vdc @ 2.5 A
01-3682A02
Omni-
Directional
Antennas
Rugged antennas well suited for use at Access
Point installations. Consult with your factory
Sales Representative for details
Call factory
Yagi Antenna
(Directional)
Rugged antennas well suited for use at Remote
installations. Consult with your factory Sales
Representative for details.
Call factory
TNC Male-to-N
Female Adapter
One-piece RF adaptor plug. 97-1677A161
TNC Male-to-N
Female Adapter
Cable
Short length of coaxial cable used to connect
the radio’s TNC antenna connector to a Type N
commonly used on large diameter coaxial
cables.
97-1677A159
(3 ft./1m)
97-1677A160
(6 ft./1.8m)
Ethernet RJ-45
Crossover
Cable (CAT5)
Cable assembly used to cross-connect the
Ethernet ports of two transceivers used in a
repeater configuration.
(Cable length ≈ 3 ft./1M)
97-1870A21
16 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
2-Pin Power
Plug
Mates with power connector on transceiver.
Screw terminals provided for wires, threaded
locking screws to prevent accidental disconnect.
73-1194A39
Ethernet RJ-45
Straight-thru
Cable (CAT5)
Cable assembly used to connect an Ethernet
device to the transceiver. Both ends of the cable
are wired identically.
(Cable length ≈ 3 ft./1M)
97-1870A20
EIA-232
Shielded Data
Cable
Shielded cable terminated with a DB-25 male
connector on one end, and a DB-9 female on the
other end. Two lengths available (see part
numbers at right).
97-3035L06
(6 ft./1.8m)
97-3035L15
(15 ft./4.6m)
EIA-232
Shielded Data
Cable
Shielded cable terminated with a DB-9 male
connector on one end, and a DB-9 female on the
other end, 6 ft./1.8m long.
97-1971A03
Fuse Small, board-mounted fuse used to protect
against over-current conditions.
29-1784A03
Flat-Surface
Mounting
Brackets &
Screws
Brackets: 2˝ x 3˝ plates designed to be screwed
onto the bottom of the unit for surface-mounting
the radio.
82-1753-A01
Screws: 6-32/1/4˝ with locking adhesive.
(Industry Standard MS 51957-26)
70-2620-A01
DIN Rail
Mounting
Bracket
Bracket used to mount the transceiver to
standard 35 mm DIN rails commonly found in
equipment cabinets and panels.
03-4022A02
COM2 Interface
Adapter
DB-25(F) to DB-9(M) shielded cable assembly
(6 ft./1.8 m) for connection of equipment or other
EIA-232 serial devices previously connected to
“legacy” units. (Consult factory for other lengths
and variations.)
97-3035A06
MDS NETview
MS Software
PC-based network management system for
new-generation MDS transceivers. Allows radio
control and diagnostics in a hierarchal map
perspective.
03-3938A01
Bandpass Filter Antenna system filter that helps eliminate
interference from nearby paging transmitters.
20-2822A02
Ethernet Surge
Suppressor
Surge suppressor for protection of Ethernet port
against lightning. 10/100BaseT compatible.
29-4018A01
Table 1-3. Accessories
Accessory Description MDS Part No.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 17
2 TABLETOP EVALUATION
AND TEST SETUP
2 Chapter Counter Reset Paragraph
Contents
2.1 OVERVIEW.............................................................................. 19
2.2 STEP 1—INSTALL THE ANTENNA CABLING........................ 19
2.3 STEP 2—MEASURE & CONNECT THE PRIMARY POWER . 20
2.4 STEP 3—CONNECT PC TO THE TRANSCEIVER................. 20
2.5 STEP 4—REVIEW TRANSCEIVER CONFIGURATION ......... 21
2.5.1 Getting Started ......................................................................... 21
2.5.2 Procedure ................................................................................. 21
2.5.3 Basic Configuration Defaults .................................................... 21
2.6 STEP 5—CONNECT LAN AND/OR SERIAL EQUIPMENT.... 22
2.7 STEP 6—CHECK FOR NORMAL OPERATION ..................... 23
18 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 19
2.1 OVERVIEW
It is best to set up a tabletop network that can be used to verify the basic
operation of the transceivers and give you a chance to experiment with
network designs, configurations or network equipment in a convenient
location. This test can be performed with any number of radios.
When you are satisfied that the network is functioning properly in a
bench setting, field installation can be performed. Complete information
for field installation, including mounting dimensions and antenna selec-
tion, is provided in INSTALLATION PLANNING on Page 129
For the following evaluation, one of the transceivers in the network must
be set to Access Point service (Device Mode = Access Point) for proper
operation.
NOTE: It is important to use a “Network Name” that is different from
any currently in use in your area during the testing period. This
will eliminate unnecessary disruption of traffic on the existing
network while you become familiar with the transceiver or
evaluate variations of unit operating parameters.
To simulate data traffic over the radio network, connect a PC or LAN to
the Ethernet port of the Access Point and PING each transceiver several
times.
2.2 STEP 1—INSTALL THE ANTENNA
CABLING
Figure 2-1 is a drawing of the tabletop arrangement. Connect the
antenna ports of each transceiver as shown. This will provide stable
radio communications between each unit while preventing interference
to nearby electronic equipment from a large number of co-located units.
Invisible place holder
Figure 2-1. Typical setup for tabletop-testing of radios
POWER ATTENUATORS
• Fixed or adjustable
• 1W Minimum Rating
POWER DIVIDER
NON-RADIATING ATTENUATORS
• Install on unused divider ports (if any)
• 1W Minimum Rating
COMPUTER
LAN COM1 COM2 PWR LINK
LAN COM1 COM2 PWR LINK
Remote
Remote
Access Point
Remote
20 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
NOTE: It is very important to use attenuation between all units in the
test setup. The amount of attenuation required will depend on
the number of units being tested and the desired signal strength
(RSSI) at each transceiver during the test. In no case should a
signal greater than –50 dBm be applied to any transceiver in
the test setup. An RF power output level of +20 dBm is recom-
mended. (See “Radio Configuration Menu” on Page 48.)
2.3 STEP 2—MEASURE & CONNECT
THE PRIMARY POWER
The primary power at the transceiver’s power connector must be within
10–30 Vdc and be capable of continuously providing a minimum of 8
Watts (typical power consumptions are: 760 mA @ 10.5 Vdc, 580 mA
@ 13.8 Vdc, and 267 mA @ 30 Vdc).
A power connector with screw-terminals is provided with each unit.
Strip the wire leads to 6 mm (0.25"). Be sure to observe proper polarity
as shown in Figure 2-2 with the positive lead (+) on the left.
NOTE: It will take about 30 seconds for the transceiver to power up
and be ready for operation.
Invisible place holder
Figure 2-2. Power Connector, Polarity: Left +, Right –
The transceiver must only be used with nega-
tive-ground systems. Make sure the polarity of the
power source is correct. The unit is protected from
reverse polarity by an internal diode and fuse.
2.4 STEP 3—CONNECT PC TO THE
TRANSCEIVER
Connect a PC’s Ethernet port to the LAN port using an Ethernet cross-
over cable. The LAN LED should light. Alternately, you can use a serial
cable to connect to the COM1 port. (Figure 2-3 on Page 23)
Wire Ports
Lead
Screws (2)
Binding
CAUTION
POSSIBLE
EQUIPMENT
DAMAGE
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 21
2.5 STEP 4—REVIEW TRANSCEIVER
CONFIGURATION
2.5.1 Getting Started
Start by logging into the Access Point. Set up the Access Point first
because the Remotes are dependent on its beacon signal to achieve the
“associated” state.
NOTE: Transceivers are shipped from the factory set to the “Remote”
mode unless they are marked differently.
Once the Access Point is up and running, move the computer connection
to each of the Remote units, log-in at each unit, review their configura-
tion, set their IP addresses and Network Name and wait for each to
achieve the associated state.
With all units associated, you will be ready to connect and test your data
services.
2.5.2 Procedure
The following is a summary of the configuration procedure that must be
done on each unit in the system. Key parameters are shown on the
Embedded Management System overview (Figure 3-1 on Page 28). A
lists of parameters can found in two tables: Table 4-5 on Page 119 and
Table 4-7 on Page 122. Detailed information on using the Management
System can be found in MS INTRODUCTION on Page 27.
NOTE: The Management System supports the use of “configuration
files” to aid in uniformly configuring multiple units. These are
detailed in Using Configuration Scripts on Page 98.
2.5.3 Basic Configuration Defaults
Table 2-1 provides a selection of key operating parameters, their range,
and default values. All of these are accessible through a terminal emu-
lator connected to the COM1 serial port or through a Web browser con-
nected to the LAN Port. (See Figure 5-1 on Page 129 for hookup.)
NOTE: Access to the transceiver’s Management System and changes
to some parameters, are controlled by password when
accessing by means of a Web browser or Telnet.
22 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
A unique IP address and subnet are required to access the browser-based
Management System either through the LAN port, or remotely
over-the-air.
2.6 STEP 5—CONNECT LAN AND/OR
SERIAL EQUIPMENT
Connect a local area network to the LAN port or serial devices to the
COM1 (DCE) or COM2 (DTE) ports. Make sure your transceivers are
capable of supporting your devices. (See Table 1-1 . Transceiver Models
and Data Interface Services, on page 5 for a summary of model capabil-
ities.) The LAN port will support any Ethernet-compatible equipment.
This includes devices that use the Internet Protocol (IP).
NOTE: If you configure COM1 for payload data service while you are
plugged into it, you will not be able to access the management
system. Alternate methods for accessing the management
system are: use Telnet or the web browser through the Ethernet
port; use Telnet or the web browser through the antenna port
(remote management).
Figure 2-3 on Page 23 shows the default functions and services for the
interface connectors.
Table 2-1. Basic Configuration Defaults
Item Menu Location Default Values/Range
Device Mode1Main Menu>>
Network Configuration>>
Device Mode
Marked on unit’s
ID label
• Access Point
• Dual Remote
• Serial Gateway
• Ethernet Bridge
Network Name Main Menu>>
Network Configuration>>
Network Name
“Not
Programmed”
• 1–15 alphanumeric
characters
• Case-sensitive;
can be mixed case
IP Address Main Menu>>
Network Configuration>>
IP Address
192.168.1.1 Contact your network
administrator
RF Output
Power
Main Menu>>
Radio Configuration>>
RF Output Power
30 dBm (1.0
Watt)
20–30 dBm @ 50Ω
(0.1–1.0 Watts)
Unit Password Main Menu>>
Device Information>>
User Password
admin
(lower case)
• 1–8 alphanumeric
characters
• Case-sensitive;
can be mixed case
1. Ethernet Bridge and Serial Gateway will not be displayed if a superior mode is autho-
rized for this unit.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 23
Invisible place holder
Figure 2-3. Interface Connectors, Functions & Defaults
2.7 STEP 6—CHECK FOR NORMAL
OPERATION
Once the data equipment is connected, you are ready to check the trans-
ceiver for normal operation.
Observe the LEDs on the top cover for the proper indications. In a nor-
mally operating system, the following LED indications will be seen
within 30 seconds of start-up:
•PWR—Lit continuously
•LINK—On, or blinking intermittently to indicate traffic flow
•LAN—On, or blinking intermittently to indicate traffic flow
Table 2-2 provides details on the LED functions.
Table 2-2. Transceiver LED Functions
LED Label Activity Indication
LAN ON LAN detected
Blinking Data TX/RX
OFF LAN not detected, or excessive
traffic present
COM1
(MGT System)
Blinking Data TX/RX
OFF No data activity
COM2 Blinking Data TX/RX
OFF No data activity
PWR ON Primary power (DC) present
Blinking Unit in “Alarmed” state
OFF Primary power (DC) absent
COM2
◆ DTE Serial Data Equip.
◆ 9,600 bps/8N1
◆ Full Handshaking
◆ RS/EIA-232.
LAN
◆ 10BaseT
◆ IP/Ethernet Port
◆IP Address: 192.168.1.1
COM1
◆DCE Console/Terminal
◆ 19,200 bps/8N1
◆No Handshaking
◆ RS/EIA-232
PRIMARY POWER
◆ 13.8 Vdc @ 500 ma
(10.5–30 Vdc)
◆ Negative Ground
◆ + Left – Right
ANTENNA
◆ 50Ω TNC
◆ +30 dBm/1W Out (Max.)
◆ –30 dBm Input (Max.)
24 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
If the radio network seems to be operating properly based on observa-
tion of the unit’s LEDs, you can use the PING command to verify the link
integrity with the Access Point or pointing your browser to another
Remote unit’s IP address in the same network.
LINK
(Access Point)
ON Default state
Blinking Data Tx/Rx
OFF Traffic exceeds the capacity of
the radio network
LINK
(Remote
Gateway)
ON Associated to AP
Blinking Data Tx/Rx
OFF Not associated with AP
Table 2-2. Transceiver LED Functions (Continued)
LED Label Activity Indication
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 25
3EMBEDDED
MANAGEMENT SYSTEM
3 Chapter Counter Reset Paragraph
Contents
3.1 MS INTRODUCTION............................................................... 27
3.1.1 Differences in the User Interfaces ............................................ 27
3.2 ACCESSING THE MENU SYSTEM ........................................ 29
3.2.1 Methods of Control ................................................................... 30
3.2.2 PC Connection & Log In Procedures ....................................... 30
3.2.3 Navigating the Menus .............................................................. 34
3.3 BASIC DEVICE INFORMATION.............................................. 36
3.3.1 Starting Information Screen ..................................................... 36
3.3.2 Main Menu ............................................................................... 37
3.3.3 Configuring Basic Device Parameters ...................................... 38
3.4 CONFIGURING NETWORK PARAMETERS .......................... 40
3.4.1 Network Configuration Menu .................................................... 40
3.4.2 IP Address Configuration Menu ............................................... 42
3.4.3 Ethernet Port Configuration Menu ............................................ 43
3.4.4 DHCP Server Configuration ..................................................... 44
3.4.5 SNMP Agent Configuration ...................................................... 46
3.5 RADIO CONFIGURATION....................................................... 48
3.5.1 Radio Configuration Menu ..................................................... 48
3.5.2 Mobile Data Configuration ........................................................ 54
3.6 CONFIGURING THE SERIAL INTERFACES.......................... 56
3.6.1 Overview .................................................................................. 56
3.6.2 Serial Data Port Configuration Menu ....................................... 59
3.6.3 Configuring for UDP Mode ....................................................... 60
3.6.4 Configuring for TCP Mode ........................................................ 64
3.6.5 Configuring for PPP Mode ....................................................... 66
3.6.6 IP-to-Serial Application Example ............................................. 67
3.6.7 Point-to-Point Serial-to-Serial Application Example ................. 68
3.6.8 Point-to-Multipoint Serial-to-Serial Application Example .......... 69
3.6.9 Mixed Modes ............................................................................ 71
3.7 SECURITY CONFIGURATION................................................ 73
26 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
3.7.1 Approved Remotes/Access Points List Menu .......................... 75
3.8 PERFORMANCE VERIFICATION ........................................... 76
3.8.1 Performance Information Menu ................................................ 76
3.8.2 Network Performance Notes .................................................... 87
3.9 MAINTENANCE....................................................................... 91
3.9.1 Reprogramming Menu ............................................................. 92
3.9.2 Configuration Scripts Menu ...................................................... 97
3.9.3 Authorization Keys Menu ......................................................... 105
3.9.4 Auto-Upgrade/Remote-Reboot Menu ....................................... 106
3.9.5 Radio Test Menu ...................................................................... 107
3.9.6 Ping Utility Menu ...................................................................... 108
3.9.7 Reset to Factory Defaults ......................................................... 108
3.9.8 Resetting the Password ........................................................... 108
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 27
3.1 MS INTRODUCTION
The transceiver’s embedded management system is accessible through
various data interfaces. These include the COM1 (serial) port, LAN
(Ethernet) port, and via SNMP. Essentially the same capabilities are
available through any of these paths.
For SNMP management, the transceiver is compatible with MDS
NETview MS™ software. Refer to MDS publication 05-2973A01 for
more information on this tool. For support of other SNMP software, a
set of MIB files is available for download from the MDS Web site at
www.microwavedata.com. A brief summary of SNMP commands can
be found at SNMP Agent Configuration section on Page 46 of this
manual.
The transceiver’s Management System and its functions are divided into
five functional groups as listed below.
•Section 3.3, BASIC DEVICE INFORMATION (beginning on
Page 36)
•Section 3.4, CONFIGURING NETWORK PARAMETERS
(beginning on Page 40)
•Section 3.5, RADIO CONFIGURATION (beginning on Page
48)
•Section 3.6, CONFIGURING THE SERIAL INTERFACES
(beginning on Page 56)
•Section 3.7, SECURITY CONFIGURATION (beginning on
Page 73)
•Section 3.8, PERFORMANCE VERIFICATION (beginning on
Page 76)
•Section 3.9, MAINTENANCE (beginning on Page 91)
Each of these sections has a focus that is reflected in its heading. The
section you are now reading provides information on connecting to the
Management System, how to navigate through it, how it is structured,
and how to perform top-level configuration tasks. Figure 3-1 on the fol-
lowing page shows a top-level view of the Management System (MS).
3.1.1 Differences in the User Interfaces
There are slight differences in navigation, but for the most part, the con-
tent is the same among different user interfaces. You will find a few dif-
ferences in capabilities as the communications tool is driven by
limitations of the access channel. Below are examples of the Starting
Information Screen seen through a terminal and a Web-browser, respec-
tively.
28 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
• Bolded items indicate a menu selection
•Spacebar used to make some menu selections
•AP = Access Point Only
• RM = Remote Only
Device Mode
Network Name
SNTP Server
Max. Remotes (AP)
Database Timeout (AP)
IP Address Config.
Ethernet Addr. Config.
DHCP Server Config.
SNMP Agent Config.
Mobility Mode
Network
Configuration Radio
Configuration Serial Gateway
Configuration Device
Information Maintenance/Tools
Security
Configuration
Reprogramming
Configuration
Scripts
Authorization Key
MAIN MENU
RF Output
Power
Data Rate (RM)
Compression (AP)
Dwell Time (AP)
Beacon Period (AP)
Performance
Information
NOTES
• Chart shows top-level view only. Details are given on the following pages.
• Not all items are user-configurable
• Some menu items depend on the Device Mode selected
RTS Threshold
RF Hopping
Format (AP)
Skip Zones (AP)
RSSI Threshold
(RMT)
SNR Threshold
(RMT)
Seamless
Inter-Frame Delay
(UDP Point-to-Point
example shown)
Serial Number
Hardware Version
Firmware Version
Console Baud Rate
Uptime
Model Number
Date Format
Time
Date
Device Names
Login Status
Two-way
Authentication
Encryption
Auto Key
Rotation (AP)
HTTP Access
SNMP Mode
Telnet Access
Approved Remotes
List (AP)
Encryption Phrase
Force Key Rotation
HTTP Security Mode
User Password
Serial Mode
Flow Control
RF Power Output
Signal-to-Noise
RSSI
Actual Data Rate
RSSI By Zone
Event Log
Packet Statistics
Remote Listing (AP)
Endpoint Listing (AP)
Remote Perf.
Listing (AP)
Radio Test
Ping Utility
Reset to Factory
Defaults
Configuration
Data Baud Rate
Packet sends
Time to Live
Local IP Port
Multicast IP Port
Multicast IP Addr.
IP Protocol
Status
COM1 & COM2
Serial Data Port
Serial Config.
Wizard
Fragmentation
Threshold
Hop Pattern
Seed (AP)
Auto Data Rate Config.
Figure 3-1. Embedded Management System—Top-level Flowchart
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 29
Figure 3-2. View of MS with a text-based program—
(Terminal Emulator shown—Telnet has similar menu structure)
Invisible place holder
Figure 3-3. View of the MS with a Browser
3.2 ACCESSING THE MENU SYSTEM
The radio has no external controls. All configuration, diagnostics and
control is performed electronically using a connected PC. This section
explains how to connect a PC, log into the unit, and gain access to the
built-in menu screens.
30 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
3.2.1 Methods of Control
The unit’s configuration menus may be accessed in one of several ways:
•Local Console—This is the primary method used for the exam-
ples in this manual. Connect a PC directly to the COM 1 port
using a serial communications cable and launch a terminal com-
munications program such as HyperTerminal. This method pro-
vides text-based access to the unit’s menu screens. Console
control is a hardware-based technique, and is intended for local
use only.
•Telnet*—Connect a PC to the unit’s LAN port, either directly or
via a network, and launch a Telnet session. This method pro-
vides text-based access to the unit’s menu screens in a manner
similar to a Local Console session. Telnet sessions may be run
locally or remotely through an IP connection.
•Web Browser*—Connect a PC to the unit’s LAN port, either
directly or via a network, and launch a web browser session
(i.e., Internet Explorer, Netscape, etc.) This method provides a
graphical representation of each screen, just as you would see
when viewing an Internet website. The appearance of menu
screens differs slightly from other methods of control, but the
content and organization of screen items is similar. Web
browser sessions may be run locally or remotely via the Inter-
net.
* Telnet and Web Browser sessions require the use of a straight-through or
crossover Ethernet cable, depending on the whether the PC-to-radio connection is
made directly, or through a network. For direct connection, a crossover cable is
required; For connection via a network, a straight-through type is needed.
Cable type can be identified as follows: Hold the two cable ends side-by-side and in
the same plug orientation (i.e., both locking tabs up or down). Now look at the
individual wire colors on each plug. If the wires on both plugs are ordered in the
same sequence from left to right, the cable is a straight-through type. If they are not
in the same order, it may be a crossover cable, or it may be wired for some other
application. Refer to DATA INTERFACE CONNECTORS on Page 143 for detailed
pinout information.
3.2.2 PC Connection & Log In Procedures
The following steps describe how to access the radio’s menu system.
These steps require a PC to be connected to the unit’s COM 1 or LAN port
as shown in Figure 3-4.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 31
Invisible place holder
Figure 3-4. PC Configuration Setup
Starting a Local
Console Session
(Recommended for
first-time Users)
1. Connect a serial communications cable between the PC and the
unit’s COM 1 port. If necessary, a cable may be constructed for this
purpose as shown in Figure 3-5.
Invisible place holder
Figure 3-5. Serial Communications Cable (RJ-11 to DB-9)
(Maximum Recommended Cable Length 50 Feet/15 meters)
2. Launch a terminal emulation program such as HyperTerminal and
configure the program with the following settings:
• 19,200 bps data rate
•8 data bits, no parity
• One stop bit, and no flow-control
• Use ANSI or VT100 emulation.
TIP: The HyperTerminal communications program can be accessed on
most PCs by selecting this menu sequence: Start>>Programs>>Accesso-
ries>>Communications>>HyperTerminal.
NOTE: The exact parameters given above must be used for console
terminal communication. Improper settings are a common
cause of difficulty.
NOTE: If the unit is powered-up or rebooted while connected to a
terminal, you will see a series of pages of text information
relating to the booting of the unit’s microcomputer. Wait for
the log-in screen before proceeding.
3. Press the key to receive the login: prompt.
Configuration PC
LAN
USB
COM1 COM2 COM3 PWR
To COM1 or LAN Port
(See Text)
Serial or Ethernet
Crossover Cable
(See Text)
RXD
TXD
GND
2
3
5
DB-9 FEMALE
(TO COMPUTER)
TXD
RXD
GND
4
5
6
RJ-11 PLUG
(TO MDS PRODUCT)
RJ-11 PIN LAYOUT
16
ENTER
32 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
4. Enter the username (default username is admin). Press .
5. Enter your password (default password is admin). (For security, your
password keystrokes do not appear on the screen.) Press .
NOTE: Passwords are case sensitive. Do not use punctuation mark
characters. You may use up to eight alpha-numeric characters.
The unit responds with the Starting Information Screen (Figure 3-6).
From here, you can review basic information about the unit or press G
to proceed to the Main Menu.
Invisible place holder
Figure 3-6. Starting Information Screen—Local Console Session
(Telnet has similar menu structure)
Starting a Telnet
Session NOTE: This method requires that you know the IP address of the unit
beforehand. If you do not know the address, use the Local
Console method (above) and access the Starting Information
Screen. The address is displayed on this screen.
1. Connect a PC to the unit’s LAN port, either directly or via a network.
If connecting directly, use an Ethernet crossover cable; if
connecting via a network, use a straight-through cable. The LAN
LED lights to indicate an active connection.
NOTE: When using a Local Area Network (LAN) to access the unit, it
may be necessary to change your computer’s IP access to the
LAN in order to be compatible with the entraNET (compatible
subnets). You can identify or verify the unit’s IP address by
using a Local Console session to communicate with the
entraNET through its COM 1 Port and viewing the Starting
Information Screen.
ENTER
ENTER
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 33
2. Start the Telnet program on your computer targeting the IP address
of the unit to which you are connected. and press .
TIP: A Telnet session can be started on most PCs by selecting:
Start>>Programs>>Accessories>>Command Prompt. At the command
prompt window, type the word telnet, followed by the unit’s IP
address (e.g., telnet 10.1.1.168). Press to receive the Telnet
log in screen.
NOTE: Never connect multiple units to a network with the same IP
address. Address conflicts will result in improper operation.
3. Enter your username (default username is admin). Press .
Next, the Password: prompt appears. Enter your password (default
password is admin). (For security, your password keystrokes will not
appear on the screen.) Press .
The unit responds with a Starting Information Screen (see
Figure 3-6). From here, you can review basic information about the
unit or press G to proceed to the Main Menu.
NOTE: Passwords are case sensitive. Do not use punctuation mark
characters. You may use up to eight alpha-numeric characters.
Starting a Web
Browser Session NOTE: Web access requires that you know the IP address of the unit
you are connecting to. If you do not know the address, start a
Local Console session (see Starting a Local Console Session
(Recommended for first-time Users) on Page 31) and access
the Starting Information Screen. The IP address is displayed
on this screen.
1. Connect a PC to the unit’s LAN port, either directly or via a network.
If connecting directly, use an Ethernet crossover cable; if
connecting via a network, use a straight-through cable. The LAN
LED lights to indicate an active connection.
2. Launch a Web-browser session on your computer (i.e., Internet
Explorer, Netscape Navigator, etc.).
3. Type in the unit’s IP address and press .
4. A log-in screen is displayed (Figure 3-7) where you enter a user
name and password to access the unit’s menu system. Note that the
default entries are made in lower case. (Default User Name: admin;
Default Password: admin)
ENTER
ENTER
ENTER
ENTER
ENTER
34 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Invisible place holder
Figure 3-7. Log-in Screen when using a Web Browser
NOTE: Passwords are case sensitive. Do not use punctuation mark
characters. You may use up to eight alpha-numeric characters.
5. Click OK. The unit responds with a startup menu screen similar to
that shown in Figure 3-8. From here, you can review basic informa-
tion about the unit or click on one of the menu items at the left side
of the screen.
Invisible place holder
Figure 3-8. Starting Information Screen—Web Browser Example
3.2.3 Navigating the Menus
Via Terminal or Telnet Sessions—Recommended for first-time users
Local Console and Telnet sessions use multi-layered text menu systems
that are nearly identical. To move further down a menu tree, you type
the letter assigned to an item of interest. This takes you to an associated
screen where settings may be viewed, or changed. In most cases,
admin
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 35
pressing the key moves the screen back one level in the menu
tree.
In general, the top portion of menu screens show read-only information
(with no user selection letter). The bottom portion of the screen contains
parameters that can be selected for further information, alteration of
values, or to navigate to other submenus.
When you arrive at a screen with user-controllable parameter fields, you
select the menu item by pressing an associated letter on the keyboard. If
there is a user definable value, the field will clear to the right of the menu
item and you can type in the value you wish to use. Follow this action
by pressing the key to save the changes. If you make a mistake
or change your mind before pressing the key, simply press
to restore the previous value.
In some cases, when you type a letter to select a parameter, you will see
a prompt at the bottom of the screen that says Choose an Option. In these
screens, press the keyboard’s to step through the available
selections. When the desired option appears, press the key to
choose that selection. In some cases, several parameters may be changed
and then saved by a single keystroke. The key can be used to
cancel the action and restore the previous values.
Logging Out Via
Terminal Emulator
or Telnet
From the Main Menu screen, press Q to quit and terminate the session.
Navigating via Web Browser
Navigating with a Web browser is straightforward with a framed
“homepage.” The primary navigation menu is permanently located on
the left-hand side of this page. Simply click on a desired menu item to
bring it to the forefront.
NOTE: To maintain security, it is best to log-out of the menu system
entirely when you are done working with it. If you do not log
out, the session automatically ends after 10 minutes of inac-
tivity.
Logging Out Via
Web Browser Click on Logout in the left-hand frame of the browser window. The
right-hand frame will change to a logout page. Follow the remaining
instructions on this screen.
NOTE: In the menu descriptions that follow, parameter options/range,
and any default values are displayed at the end of the text
between square brackets. Note that the default setting is
always shown after a semicolon: [available settings or range;
default setting]
ESCAPE
ENTER
ENTER
ESCAPE
SPACEBAR
ENTER
ESCAPE
36 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
3.3 BASIC DEVICE INFORMATION
This section contains detailed menu screens and settings that you can
use to specify the behavior of the unit.
3.3.1 Starting Information Screen
Once you have logged into the Management System, you will be pre-
sented with a screen that provides an overview of the transceiver and its
current operating condition. It provides an array of vital information and
operating conditions.
Figure 3-9. Starting Information Screen
•Device Mode—Current operating mode of the unit as it relates to
the radio network.
•Device Name—This is a user-defined parameter that will appear
in the heading of all pages.
(To change it, see Network Configuration Menu on Page 40.)
•Network Name—The name of the radio network in which the unit
is associated.
•IP Address—Unit’s IP address [192.168.1.1]
•Device Status—Condition of the unit’s association with an
Access Point.
At the Access Point:
•Alarmed—A alarm event has been logged and not cleared.
•Operational—Unit operating normally.
At a Remote:
•Scanning—The unit is looking for an Access Point beacon
signal.
•Exp(ecting) Sync(hronization)—The unit has found a valid
beacon signal for its network.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 37
•Hop Sync—The unit has changed its frequency hopping pat-
tern to match that of the Access Point.
•Associated —This unit has successfully synchronized and
associated with an Access Point.
•Alarmed—The unit is has detected one or more alarms that
have not been cleared.
NOTE: If an alarm is present when this screen is displayed, an “A)”
appears to the left of the Device Status field. Pressing the “A”
key on your keyboard takes you directly to the “Current
Alarms” screen.
•Uptime—Elapsed time since the transceiver was powered-up.
•Firmware Version—Version of firmware that is currently active in
the unit.
•Hardware Version— Hardware version of the transceiver’s printed
circuit board.
•Serial Number—Make a record of this number. It must be pro-
vided to purchase Authorization Keys to upgrade unit capabili-
ties. (See “Authorization Keys Menu” on Page 105.)
3.3.2 Main Menu
The next screen, the Main Menu, is the entryway to all user-controllable
features. The transceiver’s Device Name appears at the top of this and all
other screens as a reminder of the unit that is currently being controlled
Figure 3-10. Main Menu
•Starting Information Screen—Select this item to return to the
start-up screen. (See “Starting Information Screen” on
Page 36)
•Network Configuration—Tools to configure the data network layer
of the transceiver. (See “Network Configuration Menu” on
Page 40)
38 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
•Radio Configuration—Tools to configure the wireless (radio)
layer of the transceiver. (See “Radio Configuration Menu” on
Page 48)
•Serial Gateway Configuration—Tools to configure the two serial
ports. (See “Serial Data Port Configuration Menu” on Page 59)
•Security Configuration—Tools to configure the security services
available with the transceiver’s environment. (See “SECURITY
CONFIGURATION” on Page 73)
•Device Information—Top level user-specific and definable param-
eters, such as unit password. (See “Device Information” on
Page 38)
•Performance Information—Tools to measure the radio and data
layer’s performance of the radio network. (See “Performance
Information Menu” on Page 76)
•Maintenance/Tools—Tools to use configuration files, change
firmware and use Authorization Keys to change major unit
capabilities. (See “Authorization Key—Alter the unit’s overall
capabilities by enabling the built-in resources.
(See “Authorization Keys Menu” on Page 105)” on Page 91)
3.3.3 Configuring Basic Device Parameters
Device Information
Below is the menu/screen that displays basic administrative data on the
unit to which you are connected. It also provides access to some user-
specific parameters such as device names.
Figure 3-11. Device Information Menu
•Model Number (Display only)
•Serial Number (Display only)
•Hardware Version (Display only)
•Firmware Version (Display only)—Current firmware installed and
being used by the transceiver.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 39
•Uptime (Display only)—Elapsed time since powering up.
•Device Names Menu—Fields used at user’s discretion for general
administrative purposes. The Device Name field is used by the
transceiver as the “Realm” name for network security and in the
MS screen headings. (See Figure 3-12 on Page 39)
•Date—Current date being used for the transceiver logs. User-set-
able. (Value lost with power failure if SNTP (Simple Network
Time Protocol) server not accessible.)
•Time—Current time of day. User-setable.
Setting: HH:MM:SS
(Value lost with power failure if SNTP server not accessible.)
•Date Format—Select presentation format:
• Generic = dd Mmm yyyy
• European = dd-mm-yyyy
• US = mm-dd-yyyy
Device Names Menu
Figure 3-12. Device Names Menu
•Device Name—Device Name, used by the transceiver as the
“Realm” name for network login (web browser only) and
menu headings.
•Owner—User defined; appears on this screen only.
•Contact—User defined; appears on this screen only.
•Description—User defined; appears on this screen only.
•Location—User defined; appears on this screen only.
40 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
3.4 CONFIGURING NETWORK
PARAMETERS
3.4.1 Network Configuration Menu
The Network Configuration Menu is the home of three parameters that
should be reviewed and changed as necessary before placing a trans-
ceiver in service—Device Mode, IP Address and Network Name.
Screens for both the Access Point and Remote units are shown below.
Figure 3-13. Network Configuration Menu
From Access Point
Figure 3-14. Network Configuration Menu
From Remote Unit
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 41
•Device Mode (User Review Recommended)—Either Access Point or
a variation of a Remote. [Remote]
•Network Name (User Review Required)—Name of the radio network
of which this unit will be a part. Essential for association of
Remotes to the Access Point in the network. [Not Programmed]
TIP: For enhanced security, consider using misspelled words, a combi-
nation of letters and numbers, and a combination of upper and
lower case letters. Also, the Network Name should be at least nine
characters long. This helps protect against sophisticated hackers
who may use a database of common words (for example, dictio-
nary attacks) to determine the Network Name.
•SNTP Server—Address of SNTP server (RFC 2030) from which
the transceiver will automatically get the time-of-day startup
time. Without an SNTP server, the date and time must be man-
ually set. An AP will try to get the time and date from the SNTP
server only if an IP address is configured. It will continue to
retry every minute until it succeeds.
A remote will get the time and date from the SNTP server, if an
IP address is configured. Otherwise it gets it from the AP at
authentication time. The transceivers use UTC (Universal Time
Constant) with a configurable time offset. [0.0.0.0]
•IP Address Configuration Presents a menu for configuring the
local static IP address of the transceiver. Detailed explanations
are provided in the section titled IP Address Configuration
Menu on Page 42
•Ethernet Port Configuration—Presents a menu for defining the sta-
tus of the Ethernet port (enabled or disabled), the Ethernet rate
limit, link hardware watch (enabled/disabled), and the Ethernet
link poll address. Detailed explanations of this menu are con-
tained in Ethernet Port Configuration Menu on Page 43
•DHCP Server Config(uration)—Menu for configuration of DHCP
services by the Access Point unit. DHCP provides “on-the-fly”
IP address assignments to other LAN devices, including MDS
iNET 900 units. [Disabled]
•SNMP Config Menu—SNMP configuration parameters.
•Mobility Mode—Here, you determine whether the transceiver is
enabled or disabled for mobility operation. Note that this selec-
tion may appear on both Access Point and Remote menus, but it
only takes effect when set on Remotes. Additional settings and
information for mobility operation are contained in Mobile
Data Configuration on Page 54. [enabled, disabled; disabled].
•Maximum Remotes (AP Only)—Number of Remotes permitted to
be associated with (served by) this Access Point. [50]
42 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
•Database Timeout (AP Only)—This sets the database “age time”
(Remote Listing Menu (Access Points Only) on Page 84) to
determine when a remote is declared as unavailable. The timer
may be set from 0 to 255 minutes and resets each time a message
is received from a remote. [0–255 minutes; 5 minutes]
•Database Logging (AP Only)—Determines which types of devices
will be reported as “added” or “deleted” from the AP’s database
(See Section 3.8.1, Performance Information Menu (beginning
on Page 76). In the case of deletions, this information is trig-
gered by a timer expiration as described in the item above.
Available selections are: Remote, All (endpoints and remotes), or
Disabled.
•Ethernet Address (Display Only)—Hardware address of this unit’s
Ethernet interface.
•Wireless Address (Display Only)—Hardware address of the unit’s
wireless interface.
3.4.2 IP Address Configuration Menu
The radios use a local IP address to support remote management and
serial device services. The IP address of a radio can be set as a static IP
address or as a dynamic IP address. When static IP addressing is used,
the user must manually configure the IP address and other parameters.
When dynamic addressing is used, the radio uses a DHCP Client process
to obtain an IP address from a DHCP Server, along with other parame-
ters such as a net mask and a default gateway.
Figure 3-15. IP Address Configuration Menu
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 43
CAUTION: Changes to any of the following parameters while
communicating over the network (LAN or over-the-air) may cause
a loss of communication with the unit being configured. Commu-
nication will need to be re-established using the new IP address.
•IP Address Mode—Defines the source of the IP address of this
device. [Static, Dynamic; Static]
•Dynamic Mode—Enabling this option forces the transceiver (AP
or Remote) to obtain an IP address from any DHCP server avail-
able on the LAN. Dynamic Mode is also known as DHCP Client
mode. [Disabled]
•Static IP Address (User Review Recommended)—Essential for con-
nectivity to the transceiver’s MS via the LAN port and to send
Ethernet data over the network. Enter any valid IP address that
will be unique within the network. [192.168.1.1]
This field is unnecessary if DHCP is enabled. [255.255.0.0]
Static IP Netmask—The IPv4 local subnet mask. This field is
unnecessary if DHCP is enabled. [255.255.0.0]
•Static IP Gateway—The IPv4 address of the network gateway
device, typically a router. This field is unnecessary if DHCP is
enabled. [0.0.0.0]
The lower three lines of the screen show the actual addressing
at the transceiver whether it was obtained from static configura-
tion or from a DHCP server.
NOTE: Any change made to the above parameters results in the
Commit Changes option appearing on screen. This allows all IP
settings to be changed at the same time.
3.4.3 Ethernet Port Configuration Menu
The transceiver allows for special control of the Ethernet interface, to
allow traffic awareness and availability of the backhaul network for
redundancy purposes.
NOTE: The iNET 900 network port supports 10BaseT connections,
but does not support 100BaseT connections. This should not
present a problem because most hubs/switches auto-switch
between 10BaseT and 100BaseT connections. Confirm that
your hub/switch is capable of auto-switching data rates.
To prevent Ethernet traffic from degrading iNET 900 perfor-
mance, place the iNET in a segment, or behind routers.
44 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Figure 3-16. Ethernet Port Configuration Menu
•Ethernet port enabled/disabled—Allows remote disabling of
Ethernet traffic for security purposes. [Enabled, Disabled;
Enabled]
•Ethernet Rate Limit—The transceiver will send alarms (SNMP
traps) when the rate reaches 50%, 75%, and 100% to help iden-
tify potential problems with traffic.
•Ethernet Link (H/W) Watch (AP Only)—Detects the lack of an Ether-
net connection to the LAN port at the electrical level (link integ-
rity). The current AP will broadcast a beacon signal indicating
its “NOT AVAILABLE” status so Remotes that hear it do not
try to associate to it. Once the Ethernet connection is restored,
this beacon signal changes to “AVAILABLE” and Remotes are
allowed to join in. [Disabled]
•Ethernet Link Poll Address (AP Only)—When an IP address is pro-
vided, the Access Point pings the remote IP device every 2 min-
utes to test the integrity of the backhaul link. If this link is not
available, the AP will advertise its “NOT AVAILABLE” status
in the beacon signal so Remotes do not try to associate to it.
Once the IP address is reachable, this beacon signal changes to
“AVAILABLE” and Remotes are allowed to join in. 0.0.0.0 dis-
ables this function. Any other valid IP address enables it.
[0.0.0.0]
3.4.4 DHCP Server Configuration
A transceiver can provide automatic IP address assignments to other IP
devices in the network by providing DHCP (Dynamic Host Configura-
tion Protocol) services. This service eliminates setting individual device
IP address on Remotes in the network, but it still requires thoughtful
planning of the IP address range. One drawback to network-wide auto-
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 45
matic IP address assignments is that SNMP services may become inac-
cessible as they are dependent on fixed IP addresses.
The network can be comprised of radios with the DHCP-provided IP
address enabled or with DHCP services disabled. In this way, you can
accommodate locations for which a fixed IP address if desired.
Figure 3-17. DHCP Server Configuration Menu
NOTE: There should be only one DHCP server active in a network
(MDS iNET 900 or other DHCP server). If more than one
DHCP server exists, network devices may randomly get their
IP address from different servers every time they request one.
•Server Status—Enable/Disable responding to DHCP requests to
assign an IP address. [Disabled/Enabled; Disabled]
•DHCP Netmask—IP netmask to be assigned along with the IP
address in response to a DHCP request. [0.0.0.0]
•Starting Address—Lowest IP address of the range of addresses to
be provided by this device. [0.0.0.0]
•Ending Address—Highest IP address in the range of addresses to
be provided by this device. A maximum of 256 addresses is
allowed in this range. [0.0.0.0]
•DNS Address—Domain Name Server address to be provided by
this service.
•WINS Address—Windows Internet Naming Service server
address to be provided by this service.
•Restart DHCP Server—Selecting this option forces the transceiver
to start servicing DHCP requests using the Starting Address.
Payload data will not be interrupted but may experience some
delays as new addresses are distributed.
46 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
3.4.5 SNMP Agent Configuration
The transceiver contains over 100 custom SNMP-manageable objects as
well as the IETF standard RFC1213 for protocol statistics, also known
as MIB II. Off-the-shelf SNMP managers such as Castle Rock Com-
puting SNMPc™ and Hewlett Packard HP OpenView™ may also be
used to access the transceiver’s SNMP Agent’s MIB. The transceiver’s
SNMP agent supports SNMPv3.
The objects are broken up into nine MIB files for use with your SNMP
manager. There are textual conventions, common files and specific files.
This allows the flexibility to change areas of the MIB and not affect
other existing installations or customers.
•msdreg.mib—MDS sub-tree registrations
•mds_comm.mib—MDS Common MIB definitions for objects
and events which are common to the entire product family
•inet_reg.mib—MDS sub-tree registrations
•inettrv1.mib—SNMPv1 enterprise-specific traps
•inettrv2.mib—SNMPv2 enterprise-specific traps
•inet_comm.mib— MIB definitions for objects and events which
are common to the entire iNET Series
•inet_ap.mib—MIB definitions for objects and events for an
Access Point transceiver
•inet_sta.mib—Definitions for objects and events for a Remote
radio
•inet_sec.mib—For security management of the radio system.
SNMPv3 allows read/write operation. SNMPv1/2 allows only
for read-only access.
NOTE: SNMP management requires that the proper IP address,
network and gateway addresses are configured in each trans-
ceiver of the associated network.
In addition, some management systems may require the MIB
files to be compiled in the order shown above.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 47
Invisible place holder
Figure 3-18. SNMP Server Configuration Menu
From Access Point
This menu provides configuration and control of vital SNMP functions.
•Read Community String—SNMP community name with
SNMPv1/SNMPv2c read access. This string can be up to 30
alpha-numeric characters.
•Write Community String—SNMP community name with
SNMPv1/SNMPv2c write access. This string can be up to 30
alpha-numeric characters.
•Trap Community String—SNMP community name with
SNMPv1/SNMPv2c trap access. This string can be up to 30
alpha-numeric characters.
•V3 Authentication Password—Authentication password stored in
flash memory. This is used when the Agent is managing pass-
words locally (or initially for all cases on reboot). This is the
SNMPv3 password used for Authentication (currently, only
MD5 is supported). This string can be up to 30 alpha-numeric
characters.
•V3 Privacy Password Privacy password stored in flash memory.
Used when the SNMP Agent is managing passwords locally (or
initially for all cases on reboot). This is the SNMPv3 password
used for privacy (DES encryption). This string can be between
8 and 30 alpha-numeric characters.
•SNMP Mode—This specifies the mode of operation of the radio’s
SNMP Agent. The choices are: disabled, v1_only, v2_only,
v3_only. v1-v2, and v1-v2-v3. If the mode is disabled, the
Agent does not respond to any SNMP traffic. If the mode is
v1_only, v2_only, or v3_only, the Agent responds only to that
version of SNMP traffic. If the mode is v1-v2, or v1-v2-v3, the
Agent responds to the specified version of SNMP traffic.
[v1-v2-v3]
48 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
•Trap Version—This specifies what version of SNMP will be used
to encode the outgoing traps. The choices are v1_traps,
v2_traps, and v3_traps. When v3_traps are selected, v2-style
traps are sent, but with a v3 header. [v1 Traps, v2 Traps, v3 Traps]
•Auth Traps Status—Indicates whether or not traps will be gener-
ated for login events to the transceiver. [Disabled/Enabled; Dis-
abled]
•SNMP V3 Passwords—Determines whether v3 passwords are
managed locally or via an SNMP Manager. The different behav-
iors of the Agent depending on the mode selected, are described
in SNMP Mode above.
•Trap Manager #1–#4— Table of up to 4 locations on the network
that traps are sent to. [Any standard IP address]
NOTE: The number in the upper right-hand corner of the screen is the
SNMP Agent’s SNMPv3 Engine ID. Some SNMP Managers
may need to know this ID in order interface with the trans-
ceiver’s SNMP Agent. The ID only appears on the screen
when SNMP Mode is either v1-v2-v3 or v3_only.
3.5 RADIO CONFIGURATION
There are two primary data layers in the transceiver network—radio and
data. Since the data layer is dependent on the radio layer working prop-
erly, configuration of the radio items should be reviewed and set before
proceeding. This section explains the Radio Configuration Menu,
(Figure 3-19 for AP, Figure 3-20 for Remote). The Configuration Menu
is followed a secondary menu, the Skip Zone Options.
3.5.1 Radio Configuration Menu
Figure 3-19. Radio Configuration Menu From iNET Access Point
(iNET II data rate selection is 512/1024 kbps)
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 49
Figure 3-20. Radio Configuration Menu
From Remote Unit
•RF Output Power (User Review Recommended)—Sets/displays RF
power output level. Displayed in dBm. Setting should reflect
local regulatory limitations and losses in antenna transmission
line. (See “How Much Output Power Can be Used?” on
Page 135 for information on how to calculate this value.)
[20–30; 20]
•Data Rate (Remote Only. AP fixed is at 256/512 kbps for iNET; 512/1024
kbps for iNET II.)—Shows the over-the-air data rate setting for the
Remote radio. Remotes can operate at one of two data rates
when communicating with an AP; 256 kbps or 512 kbps (512
kbps or 1 Mbps for iNET II). 512 kbps data rates (1 Mbps for
iNET II) are possible with strong RF signal levels, typically
stronger than –77 dBm RSSI including a 15 dB fade margin.
When the data rate is set to AUTO, the remote radio is able to
change speeds based on the signal quality criteria set in the Auto
Data Rate submenu described later in this section (see Page 52).
[256, 512, AUTO; AUTO]
•Compression (AP Only)—Enabling this option uses LZO com-
pression algorithm for over-the-air data. Varying levels of data
reduction are achieved depending on the nature of the informa-
tion. Text files are typically the most compressible, whereas
binary files are the least compressible. On average, a 30%
increase in throughput can be achieved with compression
enabled.
50 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
•Dwell Time (Not applicable to iNET II)—Duration (in millisec-
onds) of one hop on a particular frequency in the hopping pat-
tern. Dwell Time should be set to 32.8 ms. (This field is only
changeable on an Access Point. Remotes get their value from
AP upon association.)
[16.4, 32.8, 65.5, 131.1, 262.1; 32.8]
TIP: If a packet is being transmitted and the dwell time
expires, the packet will be completed before hopping to the next
frequency.
•Beacon Period (Not applicable to iNET II)—Amount of time
between Beacon transmissions (in msec).
Available Intervals: Normal (104 ms), Fast (52 ms), Faster (26
ms), Slow (508 ms), Moderate (208 ms). These values provide rel-
atively quick association times where Fast is very fast (≈ 5 sec)
and the other end, the largest recommended value, the 508 ms
period is slow (≈ 60 sec). [Normal, Fast, Faster, Slow, Moderate; Nor-
mal]
TIP: Increasing the Beacon Period will provide a small
improvement in network data throughput. Shortening it
decreases the time needed for Remotes to associate with
the AP. A short beacon period is usually only a benefit
when there are mobile Remotes in the network.
•Hop Pattern Seed (AP Only; Not applicable to iNET II)—A user-select-
able value to be added to the hop pattern formula. This is done
in the unlikely event that identical hop patterns are used with
two collocated or nearby networks. Changing the seed value
will minimize the potential for RF-signal collisions in these sit-
uations. (This field is only changeable on an Access Point.
Remotes read the AP’s value upon association.) [0 to 255; 1]
•Fragment Threshold—Before transmitting over the air, if a packet
exceeds this number of bytes, the transceiver sends the packet in
multiple fragments that are reassembled before being delivered
over the Ethernet interface at the receiving end. Only even num-
bers are acceptable entries for this parameter. Over-the-air data
fragmentation is not supported on AP units. (See “Network Per-
formance Notes” on Page 87 for additional information.)
[256–1600 bytes; 1600]
TIP: In an interference-free environment this value should be
large to maximize throughput. If interference exists then
the value should be set to smaller values. The smaller the
packet the less chance of it being interfered with at the cost
of slightly reduced throughput.
•RTS Threshold—Number of bytes for the over-the-air RTS/CTS
handshake boundary. (See “Network Performance Notes” on
Page 87.) [0 to 1600 bytes; 500]
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 51
NOTE: While the transceiver accepts RTS Threshold values below
100, the lowest value that works is 100.
TIP: Lower the RTS Threshold as the number of Remotes or
overall over-the-air traffic increases. Using RTS/CTS is a
trade-off, giving up some throughput in order to prevent
collisions in a busy over-the-air network.
The RTS Threshold should be enabled and set with a value
smaller than the Fragmentation Threshold described above.
RTS forces the Remotes to request permission from the
AP before sending a packet. The AP sends a CTS control
packet to grant permission to one Remote. All other
Remotes stop transmitting for the specified amount of
time.
•RSSI Threshold (for alarm)—Level (dBm) below which the
received signal strength is deemed to have degraded, and a crit-
ical event (alarm) is generated and logged. Under these condi-
tions, the PWR lamp flashes, and a trap is sent to the trap
manager if SNMP is enabled and set properly. [0 to -120; -90]
•SNR Threshold (for alarm)—Value (dB) below which the sig-
nal-to-noise ratio is deemed to have degraded and a critical
event is generated and logged. Under these conditions, the PWR
lamp flashes, and a trap is sent to the trap manager if SNMP is
enabled and set properly. [0 to 40; Not Programmed]
•RF Hopping Format—Operation compliant to country-specific
restrictions into the frequency hopping algorithm. This option
must be specified when the order is placed and cannot be mod-
ified in the field by the user. Authorizations at time of publica-
tion:
• Australia: 915–928 MHz band
• Brazil: 902-907.5 and 915-928 MHz bands
• U.S.A. & Canada: 902–928 MHz band
•Chile: 902–928 MHz, selectable hopping, from 1 to 80 chan-
nels
•iNET II: Single-channel selectable from 2 to 79.
NOTE: Other country-specific configurations may be available.
Check with your factory sales representative for new addi-
tions.
•Skip Zones (Editable at AP Only)—Display of current utilization of
zones. Each zone consists of eight RF channels. In some
instances there may be a part of the spectrum used by another
system, that results in “continuous” or “persistent” interference
to your system. To alleviate this form of interference, the trans-
ceiver may be programmed to “block out” affected portions of
the spectrum using the Skip Zones Menu.
52 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Figure 3-21. Skip Zone Options Menu
(“Commit changes” displayed only on Access Point units)
This is a display of current utilization of 10 zones, each of eight
RF operating frequencies. Zones can be toggled between Active
and Skipped at Access Point units by first keying in the letter of
the zone to be changed, and then pressing the spacebar to toggle
between the two options for each zone. Select the Commit
Changes menu item to implement changes. These changes will
be forwarded to all units in the network through the Access
Point’s beacon signal.
A maximum of three zones can be skipped and still be compli-
ant with FCC regulations.
•Auto Data Rate Configuration—This selection brings up a submenu
as shown in Figure 3-22. For the settings in this submenu to
have any effect, the Data Rate menu item(Page 49) must be set
to AUTO.
The Auto Data Rate Configuration submenu is typically for use
in environments where signal quality is variable, and you wish
to maintain the highest possible over-the-air data rate as condi-
tions change. Mobile applications are one example of where
Auto Data Rate might be used.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 53
Invisible place holder
Figure 3-22. Auto Data Rate Menu
NOTE: In the description below, “high speed” refers to 512 kbps for
the iNET radio and 1024 kbps for the iNET II radio.
“Standard speed” refers to 256 kbps for the iNET radio and
512 kbps for the iNET II.
The Auto Data Rate Configuration submenu consists of two threshold
settings, each accompanied by a “delta” (amount of change) setting.
Using the example of Figure 3-22, assume the current RSSI is -87 dBm.
An RSSI reduction of more than 5 dBm (more negative RSSI number)
would cause a data rate change from high speed to standard speed. Once
the data speed has changed to standard speed, an RSSI increase to the
level of -82 dBm would be required for the radio to switch back to high
speed. This provides an operational “window” or hysteresis range over
which the data speed stays constant despite minor changes in signal
strength.
The SNR (signal-to-noise ratio) threshold and delta operate in the same
manner described above, with the exception that the units are expressed
in relative dB instead of dBm. In the example of Figure 3-22, a drop of
2 dB from a level of 26 dB would result in a data rate change from high
speed to standard speed. For the radio to return to high speed, the SNR
would need to increase to 28 dB. (See Glossary for definition of SNR.)
RSSI or SNR figures alone mean little when determining signal quality.
Both parameters must be considered to get a true understanding of signal
quality. For example, a strong, but noisy signal would likely be less
useful than a weak signal with low noise levels. Proper use of the
threshold and delta settings will result in smoother, more reliable perfor-
mance from your wireless link.
54 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Figure 3-22 shows the default values for RSSI and SNR parameters but
these may be changed to optimize performance in your environment. In
properly designed systems, experience has shown that RSSI levels
between -50 dBm and -90 dBm provide reliable operation, provided the
signal-to-noise ratio is 17 dB or above. Tailoring the thresholds with
these baseline values in mind, can provide improved performance in
your system.
The selections on the Auto Data Rate menu are as follows:
•ADR RSSI Threshold—A specified received signal strength value,
which, if exceeded by the range of the RSSI Delta setting, causes
a data rate change in the transceiver. [-50 to -100; -87 dBm]
•ADR RSSI Delta—A user-specified difference from the RSSI
Threshold figure which, if exceeded, causes a data rate change in
the transceiver. [0-10; 5]
•ADR SNR Threshold—A user-specified signal-to-noise ratio,
which, if exceeded by the range of the SNR Delta setting, causes
a data rate change in the transceiver. [10-30; 26]
•ADR SNR Delta—A user-specified difference from the SNR Thresh-
old figure which, if exceeded, causes a data rate change in the
transceiver. [0-10; 2]
3.5.2 Mobile Data Configuration
Because a mobile environment is more demanding than fixed-site oper-
ation, additional considerations must be made at the time of configura-
tion. These key points should be considered for all mobile installations:
• The use of middleware in the mobile laptops is important for the
correct operation of a mobile data system. This software is not pro-
vided by MDS but is available from a number of vendors. Contact
your MDS representative for suggested software.
• Configure the radios for mobile operation at the Remotes
• Set the Remote radios to standard speed (256 kbps for iNET, 512
kbps for iNET II) to optimize coverage
• Deploy Access Points so that they provide overlapping coverage
• Access Points must use the same network name to allow roaming
Enable and disable the mobility function using the Remote radio’s Net-
work Configuration Menu (see Figure 3-23). Although a menu selection
appears in the Access Point’s Network Configuration menu, this setting
may not be changed there. When you enable the Remote radio’s
Mobility Mode option, the radio scans for an alternate AP if the RSSI is
at or below the RSSI threshold defined in the Radio Configuration
screen (see Figure 3-24).
After association is lost with an AP, and scanning for an alternate AP is
started, the former AP is removed from the scan list for one minute, to
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 55
avoid linking back to the same AP. If no alternate AP is found, a link is
eventually made to the same AP as before. This is why it is important to
design a system with sufficient overlapping coverage by multiple APs.
Invisible place holder
Figure 3-23. Enabling Mobility at Remote Radio
Invisible place holder
Figure 3-24. Radio Configuration Screen—Remote
Other parameter settings that should be reviewed for Mobility Mode:
•Compression [AP; disabled]—Data compression is performed by
the middleware running on the mobile laptop PC. Gains in effi-
ciency are made because middleware compresses data at a
higher stack level, and it aggregates multiple data frames and
streams into a single packet. Compression at the radio level,
although highly efficient, works at the individual packet level.
56 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
•Dwell Time [AP; 16.4 milliseconds]—This setting controls the
amount of time that the unit spends on each frequency between
hops. Due to the varying conditions of a mobile environment,
this dwell time setting maximizes the benefits of frequency
diversity. Although overall throughput appears to decrease by
this setting, two benefits are gained: the effects of multipath fad-
ing are minimized through frequency diversity, and the com-
pression described above compensates for the decreased
throughput.
•Beacon Period [AP; Fast]—This parameter defines the interval at
which the Access Point transmits a synchronization beacon to
all remotes. This setting minimizes resynchronization times
when remote radios roam between access points or in highly
interrupted coverage areas (dense buildings, for example).
•Fragmentation Threshold [remote; 256]—This parameter defines
the size of the message packets transmitted over the wireless
media. These fragments are reconstructed into the original
packet before delivery to the external device at the remote end
of the link. In a mobile environment with rapidly changing con-
ditions, setting this value to a minimum value improves the
probability of packets being sent complete on the first try.
•RTS Threshold [AP; 0 -1600 bytes]—This setting is a wireless
equivalent to RTS/CTS flow control in a normal communica-
tions circuit. This mechanism removes packet collisions caused
by the “Hidden Node” scenario, in which remotes can’t hear
each other before transmitting. When this value is set below
100, it is essentially disabled.
•Skip Zone Options—In some instances there may be a part of the
spectrum used by another system, that results in “continuous” or
“persistent” interference to your system. To alleviate this form
of interference, the transceiver may be programmed to “block
out” affected portions of the spectrum using the Skip Zones
Menu. This menu is fully described on Page 51.
•Auto Data Rate—The transceiver’s Auto Data Rate feature can be
very helpful in mobile environments, where signal quality tends
to change rapidly. When signal quality is good, 512 kbps data
speed can be used. If signal quality degrades, the radio automat-
ically switches to 256 kbps. The criteria by which these speed
changes will occur is controlled by the parameter settings in the
Auto Data Rate Configuration submenu described on Page 52.
3.6 CONFIGURING THE SERIAL
INTERFACES
3.6.1 Overview
The transceiver includes an embedded serial device server that provides
transparent encapsulation over IP. In this capacity, it acts as a gateway
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 57
between serial and IP remote devices. Two common scenarios are PC
applications using IP to talk to remote devices, and serial PC applica-
tions talking to remote serial devices over an IP network.
Essentially the same data services are available for both serial ports:
COM1 and COM2. Note that the transceiver’s COM1 port is DCE and
COM2 is DTE. Therefore, if the RTU to be connected is also DTE, then
a null-modem cable will need to be used when connecting to COM2.
NOTE: In the discussion that follows, COM1 and COM2 will be treated
alike unless noted.
Com1 Port–Dual Purpose Capability
The COM1 port is used as a local console connection point and to pass
serial data with an external device. Setting the COM1 port status to Enable
prevents access to the Management System (MS) through this port.
However, the MS can still be accessed via the LAN port using Telnet or
a web browser.
To restore the COM1 port to support Management System services,
connect a terminal to the port, select the proper baud rate (19,200 is
default), and enter an escape sequence (+++) to reset it to the console
mode.
TCP vs. UDP
Both types of IP services are used by the transceiver embedded serial
device server—TCP and UDP. TCP provides a connection-oriented link
with end-to-end acknowledgment of data, but with some added over-
head. UDP provides a connectionless best-effort delivery service with
no acknowledgment.
Most polled protocols will be best served by UDP service as the protocol
itself has built-in error recovery mechanisms. UDP provides the needed
multidrop operation by means of multicast addressing.
On the other hand, TCP services are best suited for applications that do
not have a recovery mechanism (error-correction) and must have the
guaranteed delivery that TCP provides despite the extra overhead. The
IP-to-Serial example shows how to do this. (See “IP-to-Serial Applica-
tion Example” on Page 67.)
Serial Encapsulation
Transparent encapsulation, or IP tunneling, provides a mechanism to
encapsulate serial data into an IP envelope. Basically, all the bytes
received through the serial port are put into the data portion of a TCP or
UDP packet (TCP or UDP are user configurable options). In the same
manner, all data bytes received in a TCP or UDP packet are output
through the serial port.
58 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
When data is received by the radio through the serial port it is buffered
until the packet is received completely. There are two events that signal
an end-of-packet to the radio: a period of time since the last byte was
received, or a number of bytes that exceed the buffer size. Both of these
triggers are user configurable.
One radio can perform serial data encapsulation (IP-to-Serial) and talk
to a PC. Two radios (or one radio and a terminal server) can be used
together to provide a serial-to-serial channel.
TCP Client vs. TCP Server
On a TCP session there is a server side and a client side. The server is
always waiting for requests from clients. The transceiver can be config-
ured to act as either a server or a client.
The client mode attempts to establish a connection to a server (typically
running on a PC) whenever it receives data on the serial port.
There is also a Client/Server mode where a connection is established in
either the client or server modes. An incoming “keep alive” timer and
outgoing counter
UDP Multicast
IP provides a mechanism to do a limited broadcast to a specific group of
devices. This is known as “multicast addressing.” Many IP routers, hubs
and switches support this functionality.
Multicast addressing requires the use of a specific branch of IP
addresses set apart by the Internet Assigned Numbers Authority (IANA)
for this purpose.
UDP multicast is generally used to transport polling protocols typically
used in SCADA applications where multiple remote devices will
receive and process the same poll message.
As part of the Multicast implementation, the radio sends IGMP mem-
bership reports and IGMP queries, and responds to membership queries.
It defaults to V2 membership reports, but responds to both V1 and V2
queries.
You must configure the multicasted serial port as the target for the mul-
ticast data (for example, multipoint-to-multipoint mode, or
point-to-multipoint mode where the inbound data is multicast). This
restriction is because a host that only sends data to a multicast address
(for example, point-to-multipoint mode where the iNET 900 acts as a
point) will not join the group to receive multicast data because the host’s
inbound data is directed unicast data.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 59
The serial-to-serial example which follows shows how to provide mul-
ticast services. (See “Point-to-Multipoint Serial-to-Serial Application
Example” on Page 69.)
PPP
External devices can connect to the transceiver using PPP
(Point-to-Point Protocol). The transceiver works as a server and assigns
an IP address to the device that connects through this interface.
To gain access to the transceiver from a PC even if the network is down,
a modem may be connected to one of the transceiver’s COM ports that
has been configured with PPP.
Data Buffering
Data buffering is always active regardless of the selected mode. When
Seamless mode is selected, a buffer size of 256 bytes is used. When
custom mode is selected, the size options are: 16. 32, 64, 128, and 256
bytes. The Inter-Frame Delay is settable in either Seamless or Custom
modes.
Implementing Configuration Changes
There are several configuration parameters for the Serial Gateway found
under the Serial Configuration Menu of the Management System. After
making changes to the configuration, you must use the menu’s “Commit
Changes” to assert the changes.
If you are connecting EIA-232 serial devices to the transceiver, review
these parameters carefully.
Serial Configuration Wizard
The Serial Configuration Wizard available through the Serial Gateway
Configuration Menu is recommended for configuration of serial ports. The
wizard uses a step-by-step process, will eliminate possible conflicting
settings, and streamline complex configurations.
The wizard can be bypassed by selecting option B) View Current Settings
and adjusting the individual settings of the appropriate parameter
3.6.2 Serial Data Port Configuration Menu
The first two menu items present the identical parameter fields for each
port with one exception—Flow Control. This is available only on
COM2.
60 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Figure 3-25. Serial Configuration Wizard
•Begin Wizard—Tool for configuration of serial ports using a
step-by-step process.
•View Current Settings—Displays all settable options. Depend-
ing on the selected IP protocol.
3.6.3 Configuring for UDP Mode
Invisible place holder
Figure 3-26. UDP Point-to-Multipoint Menu
UDP point-to-multipoint to send a copy of the same packet to multiple
destinations, such as in a polling protocol.
•Status—Enable/Disable the serial data port.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 61
•IP Protocol—Point to Multipoint [TCP, UDP PPP; TCP]. This is
the type of IP port that will be offered by the transceiver’s
serial device server.
•Multicast IP Address (used instead of Local IP Address when
using UDP Point-to-Multipoint.)— Must be configured with
a valid Class D IP address (224.0.0.0–239.255.255.255). IP
packets received with a matching destination address will be
processed by this unit [Any legal IP address; 0.0.0.0].
•Multicast IP Port (used instead of Local IP Port when using UDP
Point-to-Multipoint.)—This port number must match the
number used by the application connecting to local TCP or
UDP socket. [1-64,000; COM1: 30010, COM2: 30011]
•Local IP Port—Receive IP data from this source and pass it
through to the connected serial device. The port number must
be used by the application connecting to local TCP or UDP
socket. [Any valid IP port; COM1: 30010, COM2: 30011]
•Time to Live (TTL)—An IP parameter defining the number of
hops that the packet is allowed to traverse. Every router in the
path will decrement this counter by one.
•Packet Redundancy Mode— For proper operation, all radios’
Serial Packet Redundancy mode must match (Single Packet
mode vs. Packet Repeat mode). This is because a transceiver,
when in Packet Repeat mode, sends 12 extra characters
(sequence numbers, etc.) to control the delivery of the
repeated data. Misconfigurations can result in undesired
operation.
•Data Baud Rate—Data rate (payload) for the COM port in
bits-per-second. [1,200–115,200; 19200]
•Configuration—Formatting of data bytes. Data bits, parity and
stop bits [7N1, 7E1, 7O1, 8N1, 8E1, 8O1, 8N1, 7N2, 7E2, 7O2, 8N2,
8E2, 8O2; 8N1].
•Flow Control [Com2 Only]—RTS/CTS handshaking between
the transceiver and the connected device. [Enable, Disable; Dis-
abled]
•Serial Mode—When seamless mode is selected data bytes will
be sent over the air as quickly as possible, but the receiver
will buffer the data until enough bytes have arrived to cover
worst-case gaps in transmission. The delay introduced by
data buffering may range from 22 to 44 ms, but the radio will
not create any gaps in the output data stream. This permits
operation with protocols such as MODBUS™ that do not
allow gaps in their data transmission. [Seamless, Custom;
Seamless]
•Seamless Inter-Frame Delay— Number of characters that repre-
sent the end of a message (inter-character time-out). UDP
packet sizes are delimited and sent out based on the Seamless
Inter-Frame Delay only when receiving data through the
serial port. MODBUS defines a “3.5-character” parameter.
[1–65,535; 4]
62 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
•Custom Data Buffer Size (Custom Packet Mode only)—Maxi-
mum amount of characters, that the Remote end will buffer
locally before starting to transmit data through the serial port.
[16, 32, 64, 128, 256; 32]
•Commit Changes and Exit Wizard—Save and execute changes
made on this screen (Shown only after changes have been
entered.) Invisible place holder
Figure 3-27. UDP Point-to-Point Menu
Use UDP point-to-point configuration to send information to a single
device.
•Status—Enable/Disable the serial data port.
•IP Protocol—UDP Point-to-Point. This is the type of IP port
that will be offered by the transceiver’s serial device server.
[TCP, UDP, PPP; TCP]
•Remote IP Address—Data received through the serial port is
sent to this IP address. To reach multiple Remotes in the net-
work, use UDP Point-to-Multipoint.
[Any legal IP address; 0.0.0.0]
•Remote IP Port—The destination IP port for data packets
received through the serial port on the transceiver. [1–64,000;
COM1: 30010, COM2: 30011]
•Local IP Port—Port number where data is received and passed
through to the serial port. This port number must be used by
the application connecting to this transceiver. [1–64,000;
COM1: 30010, COM2: 30011]
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 63
•Packet Redundancy Mode— For proper operation, all radios’
Serial Packet Redundancy mode must match (Single Packet
mode vs. Packet Repeat mode). This is because a transceiver,
when in Packet Repeat mode, sends 12 extra characters
(sequence numbers, etc.) to control the delivery of the
repeated data. Misconfigurations can result in undesired
operation.
•Data Baud Rate—Data rate (payload) for the COM port in
bits-per-second. [1,200–115,200; 19200]
•Configuration—Formatting of data bytes. Data bits, parity and
stop bits [7N1, 7E1, 7O1, 8N1, 8E1, 8O1, 8N1, 7N2, 7E2, 7O2, 8N2,
8E2, 8O2; 8N1].
•Flow Control (COM2 only)—RTS/CTS handshaking between
the transceiver and the connected device.
[Enable, Disable; Disabled]
•Serial Mode— When seamless mode is selected, data bytes
will be sent over the air as quickly as possible, but the
receiver will buffer the data until enough bytes have arrived
to cover worst case gaps in transmission. The delay intro-
duced by data buffering may range from 22 to 44 ms, but the
radio will not create any gaps in the output data stream. This
mode of operation is required for protocols such as MOD-
BUS™ that do not allow gaps in their data transmission.
[Seamless, Custom; Seamless]
•Seamless Inter-Frame Delay— Number of characters that repre-
sent the end of a message (inter-character time-out). MOD-
BUS defines a “3.5-character” parameter. [1–65,535; 4]
•Custom Data Buffer Size (Custom Packet Mode only)—Maxi-
mum amount of characters, that the Remote end will buffer
locally before starting to transmit data through the serial port.
[16, 32, 64, 128, 256; 32]
•Commit Changes and Exit Wizard—Save and execute changes
made on this screen (Shown only after changes have been
entered.)
64 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
3.6.4 Configuring for TCP Mode
Invisible place holder
Figure 3-28. TCP Client Menu (Remote)
•Status—Enable/Disable the serial data port.
•IP Protocol—TCP Client. This is the type of IP port that will
be offered by the transceiver’s serial device server. [TCP, UDP,
PPP; TCP]
•Primary Host Address—The IP address to be used as a destina-
tion for data received through the serial port.
[Any legal IP address; 0.0.0.0]
•Primary IP Port—The destination IP port for data packets
received through the serial port on the transceiver.
[Any valid IP port; COM1: 30010, COM2: 30011]
•Secondary Host Address—The IP address to be used as a desti-
nation for data received through the serial port in case the pri-
mary host address is not available.
[Any legal IP address; 0.0.0.0]
•Secondary IP Port—The destination IP port for data packets
received through the serial port on the transceiver used along
with the secondary host address above.
[Any valid IP port; COM1: 30010, COM2: 30011]
•Outgoing Connection’s Inactivity Timeout—Amount of time (in
seconds) that they transceiver will wait for data before termi-
nating the TCP session. [0–600; 600]
•Data Baud Rate—Data rate (payload) for the COM port in
bits-per-second. [1,200–115,200; 19200]
•Configuration—Interface signaling parameters. Data bits, par-
ity and stop bits
[7N1, 7E1, 7O1, 8N1, 8E1, 8O1, 8N1, 7N2, 7E2, 7O2, 8N2, 8E2, 8O2;
8N1].
•Flow Control [Com2 Only]—RTS/CTS handshaking between
the transceiver and the connected device.
[Enable, Disable; Disabled]
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 65
•Serial Mode— If data buffering is Enabled, the radio will oper-
ate in seamless mode. Data bytes will be sent over the air as
quickly as possible, but the receiver will buffer the data until
enough bytes have arrived to cover worst case gaps in trans-
mission. The delay introduced by data buffering may range
from 22 to 44 ms, but the radio will not create any gaps in the
output data stream. This mode of operation is required for
protocols such as MODBUS™ and some variants which do
not allow gaps in their data transmission.
[Seamless, Custom; Seamless]
•Seamless Inter-Frame Delay— Number of characters that repre-
sent the end of a message (inter-character time-out). MOD-
BUS defines a “3.5-character” parameter.
[1–65,535; 4]
•Custom Data Buffer Size (Custom Packet Mode only)—Maxi-
mum amount of characters, that the Remote end will buffer
locally before starting to transmit data through the serial port.
[16, 32, 64, 128, 256; 32]
•Commit Changes and Exit Wizard—Save and execute changes
made on this screen (Shown only after changes have been
entered.) Invisible place holder
Figure 3-29. TCP Server Menu (AP)
•Status—Enable/Disable the serial data port.
•IP Protocol—TCP Server. This is the type of IP port that will
be offered by the transceiver’s serial device server.
[TCP, UDP, PPP; TCP]
•Local Listening IP Port—Receive IP data from this source and
pass it through to the connected serial device. The port num-
ber must be used by the application connecting to local TCP
or UDP socket.
[Any valid IP port; COM1: 30010, COM2: 30011]
66 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
•Data Baud Rate—Data rate (payload) for the COM port in
bits-per-second. [1,200–115,200; 19200]
•Configuration—Interface signaling parameters. Data bits, par-
ity and stop bits
[7N1, 7E1, 7O1, 8N1, 8E1, 8O1, 8N1, 7N2, 7E2, 7O2, 8N2, 8E2, 8O2;
8N1].
•Flow Control (COM2 only)—RTS/CTS handshaking between
the transceiver and the connected device.
[Enable, Disable; Disabled]
•Serial Mode— If data buffering is Enabled, the radio will oper-
ate in seamless mode. Data bytes will be sent over the air as
quickly as possible, but the receiver will buffer the data until
enough bytes have arrived to cover worst case gaps in trans-
mission. The delay introduced by data buffering may range
from 22 to 44 ms, but the radio will not create any gaps in the
output data stream. This mode of operation is required for
protocols such as MODBUS™ and some variants which do
not allow gaps in their data transmission.
[Seamless, Custom; Seamless]
•Seamless Inter-Frame Delay— Number of characters that repre-
sent the end of a message (inter-character time-out). MOD-
BUS defines a “3.5-character” parameter. [1–65,535; 4]
•Custom Data Buffer Size (Custom Packet Mode only)—Maxi-
mum amount of characters, that the Remote end will buffer
locally before starting to transmit data through the serial port.
[16, 32, 64, 128, 256; 32]
•Commit Changes and Exit Wizard—Save and execute changes
made on this screen (Shown only after changes have been
entered.)
3.6.5 Configuring for PPP Mode
Invisible place holder
Figure 3-30. PPP Menu
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 67
•Status—Enable/Disable the serial data port.
•IP Protocol—PPP. This is the type of IP port that will be offered
by the transceiver’s serial device server. [TCP, UDP, PPP; TCP]
•Device IP Address—IP address that will be assigned to the dialing
device once the connection is established. [0.0.0.0]
•Data Baud—The baud rate of the serial port of the transceiver to
which the external device is connected.
[1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200; 19200]
•Configuration—Byte format of the serial port
[7N1, 7E1, 701, 7N2, 7E2, 702, 8N1, 801, 8N2, 8E2, 802; 8N1]
•Flow Control (COM2 only)—RTS/CTS handshaking between the
transceiver and the connected device.
[Enable, Disable; Disabled]
•Serial Mode—When seamless mode is selected, data bytes will be
sent over the air as quickly as possible, but the receiver will
buffer the data until enough bytes have arrived to cover worst
case gaps in transmission. The delay introduced by data buffer-
ing may range from 22 to 44 ms, but the radio will not create any
gaps in the output data stream. This mode of operation is
required for protocols such as MODBUS™ that do not allow
gaps in their data transmission. [Seamless, Custom; Seamless]
•Seamless Inter-Frame Delay— Number of characters that represent
the end of a message (inter-character time-out). MODBUS
defines a “3.5-character” parameter. [1–65,535; 4]
•Custom Data Buffer Size (Custom Packet Mode only)—Maxi-
mum amount of characters, that the Remote end will buffer
locally before starting to transmit data through the serial port.
[16, 32, 64, 128, 256; 32]
•Commit Changes and Exit Wizard—Save and execute changes made
on this screen (Shown only after changes have been entered.)
A PPP session shows the following possible states:
•Sending LCP Requests—The PPP server is querying for any cli-
ents that need to connect.
•Link Established—A successful PPP connection has been negoti-
ated and an IP address is assigned.
•Port not Enabled—The serial port is disabled.
3.6.6 IP-to-Serial Application Example
You have a choice to use UDP or TCP to establish communications.
This will depend on the type of device you are communicating with at
the other end of the IP network. In this example we will use TCP to illus-
trate its use.
In TCP mode, the transceiver remains in a passive mode offering a
socket for connection. Once a request is received, data received at the
serial port will be sent out through the IP socket and vice versa, until the
68 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
connection is closed, or the link is interrupted. In this mode, the trans-
ceiver behaves the same, whether it is an Access Point or a Remote.
(See Figure 3-31 and Table 3-1)
NOTE: The TCP session has a timeout of 10 minutes (600 seconds). If
inactive for that time, it will be closed. The transceiver will
offer the port again for connection after this time expires.
Establishing a
Connection From the PC, establish a TCP connection to the IP address of the
Remote transceiver and to the IP port as configured above (30010—
COM1, 30011—COM2). A Telnet client application can be used to
establish this connection. Data can now be sent between the PC and the
RTU or other connected device.
Invisible place holder
Figure 3-31. IP-to-Serial Application Diagram
3.6.7 Point-to-Point Serial-to-Serial Application
Example
Once the transceivers are configured and the changes have been exe-
cuted, they begin processing any data presented at the COM ports. Data
presented at the Access Point’s COM port will be packetized and sent via
UDP to the Remote. Upon receiving the packet, the Remote strips the
data out of the UDP packet and sends it out its COM port. Likewise, data
presented at the Remote’s COM port is packetized, sent to the Access
Point, stripped, and sent out the Access Point’s COM port. Note, this
configuration does not use multicast addressing.
Ethernet
Crosssover
RTU
EIA-232
Computer
or Network
192.168.0.10 192.168.0.1 192.168.0.2
LA
NCOM
1COM
2PW
RLIN
K
Remote
Access Point
Table 3-1. Serial Port Application Configuration
IP-to-Serial Connection
Transceiver
Location Menu Item Setting
Access Point None is required None is required
Remote Unit IP Address 192.168.0.2
Status Enabled
IP Protocol TCP
Baud Rate 9,600 (Example)
Flow Control None
Local IP Port 30011
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 69
Invisible place holder
Figure 3-32. Point-to-Point Serial-to-Serial Application Diagram
3.6.8 Point-to-Multipoint Serial-to-Serial Application
Example
The operation and data flow for this mode is very similar to
Point-to-Point serial-to-serial application, except that it uses multicast
addressing. The primary difference is that data presented at the Access
Point’s COM port will be packetized and sent via UDP to all of the
Remotes. Upon receiving the packet all of the Remotes strip the data out
of the UDP packet and send it out their COM port. Likewise, data pre-
sented at any of the Remotes’ COM ports is packetized, sent to the
EIA-232
RTU
EIA-232
Terminal
or Computer
192.168.0.10 192.168.0.1 192.168.0.2
Remote
Access Point
LA
NCOM
1COM
2PW
RLIN
K
Table 3-2. Serial Port Application Configuration
Transceiver Location Menu Item Setting
Access Point (COM2)1Status Enabled
Data Baud Rate 9,600 (Example)
Flow Control Hardware (Example)
Serial Mode Seamless
SIFD 4
IP Protocol UDP
Remote IP
Address
192.168.0.2
(IP address of the Remote radio)
Remote IP Port 30011
Local IP Port 30011
Remote Unit (COM2)1Status Enabled
Data Baud Rate 9,600 (Example)
Flow Control X-ON/X-OFF (Example)
Serial Mode Seamless
SIFD 4 (Characters)
IP Protocol UDP
Remote IP
Address
192.168.0.1
(IP address of the AP)
Remote IP Port 30011
Local IP Port 30011
1. Either COM port can be used, but they must be the same ones at both ends
of the link. Both COM ports can be used simultaneously for two independent
data channels.
70 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Access Point, stripped, and sent out the Access Point’s COM port (see
Figure 3-33, Table 3-3, Figure 3-34, and Figure 3-35 on Page 71.
Invisible place holder
Figure 3-33. Point-to-Multipoint Serial-to-Serial Application
Diagram
Invisible place holder
192.168.0.3
192.168.0.4
EIA-232
Terminal
or Computer
RTU
RTU
RTU
EIA-232
EIA-232
EIA-232
192.168.0.10 192.168.0.1
192.168.0.2
Access Point
LA
NCOM
1COM
2PW
RLIN
K
Remote
LA
NCOM
1COM
2PW
RLIN
K
Remote
LA
NCOM
1COM
2PW
RLIN
K
Remote
Table 3-3. Serial Port Application Configuration
Transceiver Location Menu Item Setting
Access Point (COM2)1Status Enabled
Baud Rate 9600 (Example)
Serial Mode Custom
Flow Control Disabled
IP Protocol UDP
Remote IP Address 224.254.1.1—
Multicast Address2
Remote IP Port 30011
Local IP Port 30011
Remote Units (COM2)1Enable Enabled
Baud Rate 2,400 (Example)
Serial Mode Custom
Flow Control Hardware (Example)
IP Protocol UDP
Remote IP Address 192.168.0.1
Remote IP Port 30011
Local IP Port 30011
Local Multicast
Address
224.254.1.1 —
Multicast Address2
1. Either COM port can be used, but they must be the same ones at
both ends of the link. Both COM ports can be used simultaneously for
two independent data channels.
2. This address is an example only. Any Class D IP address
(224.0.0.0–239.255.255.255) will work.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 71
Figure 3-34. Access Point Serial Port Configuration
Figure 3-35. Remote Radio Serial Port Configuration
3.6.9 Mixed Modes
Note that in this example, the TCP mode does not involve the Access
Point. Thus, the transceiver in a single network can run in both modes at
the same time. In other words, some Remotes can be configured for TCP
mode while others can be configured (along with the Access Point) for
UDP mode.
In this configuration, the Host PC can use both data paths to reach the
RTUs. This may be helpful when a mixed collection of RTUs is present
where some RTUs can operate in a broadcast form while others cannot
(see Figure 3-36 on Page 72 and Table 3-4 on Page 72).
72 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Operation and Data Flow
• Communicate with RTU A by Telneting to Remote 1, port 30011.
• Communicate with RTU B by Telneting to Remote 2, port 30011.
• Communicate with RTUs C and D by sending and receiving data
from the Access Point’s COM port.
• All communication paths can be used simultaneously.
Invisible place holder
Figure 3-36. Mixed-Modes Application Diagram
EIA-232
Terminal
or Computer
RTU–C
EIA-232
EIA-232
EIA-232
RTU–D
EIA-232
LA
NCOM
1COM
2PW
RLIN
K
iNET 900
Remote 4
Ethernet
Crosssover
RTU–B
RTU–A
iNET 900
Access Point
LA
NCOM
1COM
2PW
RLIN
K
iNET 900
Remote 1
LA
NCOM
1COM
2PW
RLIN
K
iNET 900
Remote 2
LA
NCOM
1COM
2PW
RLIN
K
iNET 900
Remote 3
Table 3-4. Serial Port Application Configuration
Transceiver Location Menu Item Setting
Access Point Status Enabled
Baud Rate 9,600
Flow Control Disabled
IP Protocol UDP
Send to Address A multicast IP address such as
224.254.1.1
Send to Port 30011
Receive on Port 30011
Receive on Address 0.0.0.0 (Not Used)
Remote Units 1 & 2
(COM2)
Status Enabled
Baud Rate 2,400
Flow Control Disabled
IP Protocol TCP
Receive on Port 30011
Remote Units 3 & 4
(COM2)
Status Enabled
Baud Rate 9,600
Flow Control Disabled
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 73
3.7 SECURITY CONFIGURATION
There are many options to assist you in providing secondary security for
your transceivers and the network. These options start with controlling
remote access to the network via Telnet, Web Browser, and SNMP.
Other areas include multiple levels of encryption and MD5-level secu-
rity for HTTP connections.
Figure 3-37. Security Configuration Menu
(Access Point Version Shown)
•Two-Way Authentication— Enable provisioning at the Remote.
[Enabled/Disabled; Disabled]
Enabling forces the transceiver to check the Approved AP List
before continuing the authorization process. In the case of a
Remote, the AP must be in the Approved Access Points List
before it accepts the beacon as valid. In the case of an AP, a
Remote must be in the Approved Remotes List to be granted
authorization. Before enabling this option, at least one entry
must already exist in the Approved List.
IP Protocol UDP
Send to Address IP address of the AP
Send to Port 30011
Receive on Port 30011
Receive on Address 224.254.1.1
(The multicast IP address used
for the AP’s Send To Address
above)
Table 3-4. Serial Port Application Configuration (Continued)
Transceiver Location Menu Item Setting
74 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
•Encryption— Enable encryption of over-the-air data packets.
[Enabled, Disabled; Disabled]
Enabling forces the transceiver to use 128-bit encryption on all
over-the-air messages. This option requires the Encryption
Phrase to be previously configured.
•Auto Key Rotation—Enable automatic rotation of encryption
keys. [Enabled, Disabled; Disabled]
Enabling forces the transceiver to use the key rotation algorithm
to generate a new encryption key after 500 kilobytes of informa-
tion has been transmitted, or one hour has elapsed. Key rotation
prevents reusing encryption data that could result in key-crack-
ing, unlike standard 802.11b communications that rely on static
encryption keys.
•HTTP Access—Prevents remote access through HTTP (Web
browser) on Port 80 [Enabled/Disabled; Disabled]
•SNMP Access— Prevents remote access through SNMP com-
mands on Port 161 [Enabled, Disabled; Enabled]
•Telnet Access—Prevents remote access through Telnet sessions
on Port 23 [Enabled, Disabled; Enabled]
•Approved Access Points/Remotes List (Menu)—Go to menu pro-
viding the creation and management list of units permitted (pro-
visioned) with which this unit will be permitted to
communicate.
•Encryption Phrase—Phrase (text & numbers) that will be part of
the encryption algorithm.
[Up to 29 alphanumeric characters; Blank]
•Force Key Rotation— It triggers an immediate key rotation of the
encryption keys before the internal counters do it automatically.
•HTTP Security Mode—Select security mode/level of login via
HTTP browser. HTTP Access disabled prevents access through
HTTP. HTTP Security Mode is functional if HTTP Access is
enabled. [Basic Auth, MD5 Digest; Basic Auth]
Basic mode requires a password, but the actual password text is
transmitted in the clear (unencrypted).
•User Password—General administrative password only for this
unit. Used at log-in via COM1 Port, Telnet and Web browser.
[Up to 8-character alphanumeric string without spaces (case-sensitive);
admin]
TIP: For enhanced security, consider using misspelled words, a combi-
nation of letters and numbers, and a combination of upper and
lower case letters. Also, the password should use all eight charac-
ters. This helps protect against sophisticated hackers who may use
a database of common words (for example, dictionary attacks) to
determine a password.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 75
3.7.1 Approved Remotes/Access Points List Menu
This menu is the same for both Access Points and Remotes and the
names change to reflect their mode. Replace “Remotes” with Access
Points” in the following description.
NOTE: The limit for remotes (in an Access Point) is 255.
The limit for Access Points (in a remote) is 104.
Figure 3-38. Approved Remotes List Menu
•Add Remote—Enter MAC address of Remote.
[Any valid 6-digit hexadecimal MAC address; 00:00:00:00:00:00]
•Delete Remote—Enter MAC address of Remote.
For security purposes, you may want to delete a stolen or depro-
visioned radio.
•Add Associated Remotes—Add all currently associated remotes to
the approved remote list. Alternatively, you can enter each
Remote MAC manually.
•Delete All Remotes—Remove (complete purge) of all Remotes
from current list.
•View Approved Remotes—Simple listing of approved Remotes by
MAC address, of radios authorized to join this AP. If a Remote
is not in this list, it will not be able to associate with this AP.
•Save Changes—Save all changes made during this session with
this menu. Changes will be implemented only if they are
“saved” before exiting this menu.
76 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
3.8 PERFORMANCE VERIFICATION
After the basic operation of the radio has been checked, you may wish
to optimize the network’s performance using some of the following sug-
gestions. The effectiveness of these techniques will vary with the design
of your system and the format of the data being sent.
There are two major areas for possible improvement—the radio and the
data network. The following sections will provide you with a variety of
items to check and on many occasions, ways to correct or improve their
performance.
3.8.1 Performance Information Menu
This menu/screen is one of two primary sources of information on the
radio layer and radio network performance.
Figure 3-39. Performance Information Menu
(AP Version Shown)
•RF Output Power (Display only)—Measured power output.
(See “How Much Output Power Can be Used?” on Page 135)
•Signal-to-Noise (Display only)—Current running-average SNR
value all active operating frequencies.
(No value displayed on APs)
•RSSI (Display only)—Current running-average Received Signal
Strength Indication for all active operating frequencies.
(No value displayed on APs.)
•Actual Data Rate (Display only)—Over-the-air transmission rate (as
opposed to selected data rate) for the remote being monitored.
The fastest data rates can generally be achieved with stronger
signal levels.
•RSSI by Zone—Received Signal Strength Indicator by Zone.
(See “RSSI by Zone Menu (Remotes Only)” on Page 77)
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 77
•Event Log—Access the menu for managing the unit’s log of
operational activities.(See “Authorization Key—Alter the
unit’s overall capabilities by enabling the built-in resources.
(See “Authorization Keys Menu” on Page 105)” on Page 91)
•Packet Statistics—Multiple radio and network operating statis-
tics. (See “Packet Statistics Menu” on Page 81)
•Wireless Network Status (Displayed only at Remotes)—Current associ-
ation state and MAC address of the Access Point.
(See “Wireless Network Status (Remotes Only)” on Page 83)
•Remote Listing (AP Display only) —List of basic information for all
Remote units currently associated with this Access Point.
(See “Remote Listing Menu (Access Points Only)” on Page 84)
•Endpoint Listing (AP Display only)—List of units accessible by this
AP through associated Remote ports.
(See “Endpoint Listing Menu (Access Points Only)” on
Page 85)
•Remote Performance Listing (AP Display only)—(See “Remote Per-
formance Listing Menu (Access Points Only)” on Page 86)
RSSI by Zone Menu (Remotes Only)
This screen displays the strength of RF signals received from the cur-
rently associated Access Point.
Network integrity depends in large part on stable radio signal levels
being received at each end of a data link. In general, signal levels
stronger than –80 dBm will provide reliable communication that
includes a 15 dB fade margin.
If you find there is a poor signal level on one zone, check the Packet Sta-
tistics Menu section on Page 81 and record the values. Then, set the
questionable zone to “Skipped” in the Radio Configuration Menu (Page
48) and look for an improvement in the Packet Statistics error rates. If
there is none, return the Zone to “Active.”
RSSI measurements and Wireless Packet Statistics are based on mul-
tiple samples over a period of several seconds. The average of these
measurements will be displayed by the Management System.
78 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Figure 3-40. RSSI by Zone Menu
TIP: Under normal circumstances, the signal levels in each zone should
be within a few decibels of each other. If you see one that is signif-
icantly lower or higher, it may be a sign of radio frequency inter-
ference from another signal source on the 900 MHz band.
See “Network Performance Notes” on Page 87 for further infor-
mation.
Event Log Menu
The transceiver’s microprocessor monitors many operational parame-
ters and logs them. Events are classified into four levels of importance,
which are described in Table 3-5. Some of these events will result from
a condition that prevents the normal of the unit—these are “critical”
events. These will cause the unit to enter an “alarmed” state and the PWR
LED to blink until the condition is corrected. All events are stored in the
Event Log that can hold up to 8,000 entries.
Time and Date The events stored in the Event Log are time-stamped using the time and
date of the locally connected device. Remote units obtain this informa-
tion from the Access Point when they associate with it. The Access Point
obtains the time and date from a Time Server. This server can generally
be provided by a standard Windows PC server SNTP application. In the
absence of the SNTP services, the user must manually enter it at the
Table 3-5. Event Classifications
Level Description/Impact
Informational Normal operating activities
Minor Does not affect unit operation
Major Degraded unit performance but
still capable of operation
Critical Prevents the unit from operating
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 79
Access Point. (See “Device Information” on Page 38 for SNTP server
identification.) The manually set time and date clock is dependent on the
unit’s primary power. A loss of power will reset the clock to January 1,
2002 but will not affect previously stored error events.
Figure 3-41. Event Log Menu
•Current Alarms (Telnet/Terminal only)—View list of root causes that
have placed the Device Status in the alarmed state. (See “Alarm
Conditions” on Page 118)
•View Log—View a list of events stored in the current log. Some
of these events are stored in volatile memory and will be erased
with a loss of power. The events are numbered for easier iden-
tification and navigation.
•Clear Log—Purges the log of all events
TIP: Save your Event Log before choosing to clear it in order
to retain potentially valuable troubleshooting information.
(See “Upgrading the Firmware” on Page 93 for an over-
view on how to transfer files from the transceiver to a com-
puter on the network using TFTP.)
•Send Log (Telnet/Terminal only)—Initiate TFTP transfer of the
unit’s event Event Log in a plain text (ASCII) file to a TFTP
server at the remote location.
•TFTP Host Address (Telnet/Terminal only)—IP address of the com-
puter on which the TFTP server resides. This same IP address is
used in other screens/functions (reprogramming, logging, etc.).
Changing it here also changes it for other screens/functions.
[Any valid IP address; 127.0.0.1]
80 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
•Filename (Telnet/Terminal only)—Name to be given to the Event
Log file sent to the TFTP server for archiving.
[Any 40-char alphanumeric string; Blank]
NOTE: You may want to change the filename to reflect the type
of log you intend to archive and/or its date.
•TFTP Time-out (Telnet/Terminal only)—Time in seconds the TFTP
server will wait for a packet ACK (acknowledgment) from the
transceiver before suspending the file transfer.
[10 to 120 seconds; 10]
•Syslog Server—IP address to which alarms are sent using the sys-
log message format. [Any valid IP address; 0.0.0.0]
View Current Alarms Most events, classified as “critical” will make the PWR LED blink, and
will inhibit normal operation of the transceiver. The LED will remain
blinking until the corrective action has been completed.
An alarm condition is different from a log event in the sense that an
alarm is persistent in nature. That is, an alarm condition remains as an
alarm until it has been cleared by correcting the cause (see Table 4-6 on
Page 120 for corrective action).
Figure 3-42. Current Alarms Screen
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 81
View Event Log See Table 4-4 on Page 118 for event classifications.
Figure 3-43. Sample Event Log Screen
Packet Statistics Menu
Figure 3-44. Sample Packet Statistics Menu
Wireless Packet
Statistics •Packets received—Over-the-air data packets received by this unit
•Packets sent—Over-the-air data packets sent by this Remote.
•Bytes received—Over-the-air data bytes received by this Remote.
•Bytes sent—Over-the-air data bytes sent by this Remote.
•Packets dropped—To-be-transmitted packets dropped as a result
of a lack of buffers in the RF outbound queue.
•Receive errors—Packets that do not pass CRC. This may be due
to transmissions corrupted by RF interference.
82 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
•Retries—Number of requests to re-send a data packet before it is
acknowledged. If the packet was not acknowledged, this
counter is not incremented.
•Retry errors—Packets discarded after exceeding seven retries
over-the-air.
•Clear Wireless stats—Resets the statistics counter.
Ethernet Packet
Statistics •Packets received—Packets received by the transceiver through
the Ethernet port.
•Packets sent—Packets transmitted by the transceiver through the
Ethernet port.
•Bytes received—Data bytes received by this Remote through its
LAN port.
•Bytes sent—Data bytes sent by this Remote.
•Packets dropped—Received packets dropped as a result of a lack
of buffers.
•Receive errors—Packets that do not pass CRC. This may be due
to collisions in the Ethernet LAN.
•Lost carrier detected—A count of the number of packets that the
unit attempted to send out the Ethernet port when the carrier sig-
nal of the Ethernet was not present. (No carrier present could be
due to a loose connection, bad or wrong cable, or equipment
failure at the other end of the Ethernet cable.)
•Clear Ethernet stats—Resets the statistics counter.
Packets Received by
Zone This screen, shown in Figure 3-45, presents a breakdown of wireless
packet statistics by-zone. All zones should report similar numbers. If
one or more zones report lower numbers than the others (2% reduction),
the specific zone is probably experiencing interference. An improve-
ment can be realized by blocking this zone (see Main Menu>>Radio Config-
uration>>Skip Zone Option).
Invisible place holder
Figure 3-45. Packets Received By Zone Menu
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 83
Wireless Network Status
(Remotes Only)
The Wireless Network Status screen provides information on a key
operating process of the transceiver—the association of the Remote with
the Access Point. The following is a description of how this process
takes place and as monitored on the Figure 3-46. Wireless Network
Status Screen" on page 83.
The Transceiver’s
Association Process After the Remote is powered up and finishes its boot cycle, it begins
scanning the 900 MHz band for beacon signals being sent out from AP
units. If the Remote sees a beacon with a Network Name that is the same
as its own, the Remote will stop its scanning and temporarily synchro-
nize its frequency-hopping pattern to match the one encoded on the AP’s
beacon signal. The Remote waits for three identical beacon signals from
the AP and then it toggles into a fully synchronized “associated” state.
If the Remote does not receive three identical beacons from the Access
Point unit within a predetermined time period, it returns to a scanning
mode and continues to search for an AP with a matching network name
in its beacon.
Under normal circumstances, the association process should be com-
pleted within 20 seconds after boot-up. This time can vary depending on
the beacon period setting at the AP. See Beacon Period description in Sec-
tion 3.5.1, Radio Configuration Menu (beginning on Page 48).
Remote units are always monitoring the beacon signal. If an associated
Remote loses the AP’s beacon for more than 20 seconds, the association
process starts again.
The Wireless
Network
Status Screen
(Remote only)
Figure 3-46. Wireless Network Status Screen
•Connection Status—Current state of the wireless network com-
munication.
84 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
•Scanning—The unit is looking for an Access Point beacon
signal.
•Exp(ecting) Sync(hronization)—The unit has found a valid
beacon signal for its network.
•Hop Sync—The unit has changed its frequency hopping pat-
tern to match that of the Access Point.
•Associated —This unit has successfully synchronized and
associated with an Access Point. This is the normal status.
•Alarmed—The unit is has detected one or more alarms that
have not been cleared.
•Current AP Mac Address—Wireless address of Access Point with
which the Remote is associated.
•Current AP IP Address—IP address of Access Point with which
the Remote is associated.
•Association Date—Date of last successful association with an
Access Point.
•Association Time—Time of day association was established on
the association date.
•Latest AP Firmware Version—
•AP Auto Upgrade—
•AP Reboot when Upgraded—
Remote Listing Menu (Access Points Only)
Figure 3-47. Remote Listing Menu
(List of transceivers associated with this AP)
•MAC Address—Hardware address of the Remote transceiver.
•IP Address—IP Address of the Remote transceiver.
•State—Current association state of the Remote transceiver.
•AgeTime—Time, in minutes, remaining before the device (address)
will be deleted from the table.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 85
Each transceiver maintains a table with the addresses of the devices
it communicates with. The age-time countdown is restarted to 5
minutes every time a message to/from that device is detected. If no
traffic is exchanged with that device, it then “ages out” of the table.
When traffic is detected it is included again in the table. This opti-
mizes memory space utilization.
•DataRate—Supported data rate by this unit.
Endpoint Listing Menu
(Access Points Only)
This list shows all of the non-iNET 900 Ethernet devices that are known
to the transceiver and is equivalent to the ARP table of IP devices.
Figure 3-48. Endpoint Listing Menu
(Lists all equipment attached to REMOTE transceivers in the network)
•MAC Address—Hardware address of endpoint device.
•IP Address—IP Address of endpoint device.
•AgeTime—Time, in minutes, remaining before the device (address)
will be deleted from the table.
Each AP maintains a table with the addresses of the remote radios it
communicates with. The age-time countdown is restarted to 5 min-
utes every time a message to/from that remote is detected. If no traf-
fic is exchanged with that remote, it then “ages out” of the table.
When traffic is detected it is included again in the table. This opti-
mizes memory space utilization.
•via Remote—Hardware address of the transceiver connected to this
device.
•RxPkts—Over-the-air data packets received by the transceiver. and
passed on to the endpoint device.
86 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
•TxPkt—Number of packets received from the endpoint device and
passed over-the-air.
Remote Performance Listing Menu
(Access Points Only)
Figure 3-49. Remote Performance Listing Menu for iNET AP
(iNET II will show RxRate as 512 kbps or 1024 kbps)
This screen provides a unit-by-unit summary of all Remote units cur-
rently associated with this Access Point. The parameters are displayed
in a column format with each line corresponding to one Remote.
•RxRate—Over-the-air data rate the radio is currently using. All
transceivers do not need to use the same rate.
•RxPkts—Over-the-air data packets received from this unit.
•TxPkts—Over-the-air data packets sent to this unit.
•RxBCMC—Total number of Broadcast and/or Multicast packets
received over-the-air.
•RxViaEP—Packets received by the transceiver through the Ether-
net port.
•TxViaEP—Packets sent by the transceiver through the Ethernet
port.
•RetryEr—Packets discarded after exceeding five retries
over-the-air.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 87
Serial Data Statistics Menu
This screen provides a summary of port activity for both serial data
ports. These values will be reset to zero after a reboot cycle.
Figure 3-50. Serial Data Statistics Screen
(Both COM1 and COM2 will be shown)
•Bytes in on port—Number of bytes received by the transceiver
through the serial interface
•Bytes out on port—Number of bytes transmitted by the trans-
ceiver through the serial interface
•Bytes in on socket—Number of bytes received by the trans-
ceiver through the IP socket
•Bytes out on socket—Number of bytes transmitted by the trans-
ceiver through the IP socket
In general, the number of bytes Out on Socket should follow
the number of bytes In On Port as all bytes received on the
serial port should be transmitted out to the IP interface. The
same should be true in the opposite direction, bytes Out On
Port should follow bytes In On Socket.
•Clear Com1 Statistics—Resets counter to zero.
•Clear Com2 Statistics—Resets counter to zero.
3.8.2 Network Performance Notes
Principles of Network Operation
The following is a list of points that are useful for dealing with the net-
working aspects of the transceiver.
1. The transceiver serves as a network bridge.
88 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
• The radio goes through a listening and learning period at
start-up before it will send any packets over either of its ports.
This is about 10 seconds after the CPU’s operating system has
finished its boot cycle.
•The bridge code in the transceiver operates and makes decisions
about packet forwarding just like any other bridge. The bridge
code builds a list of source MAC addresses that it has seen on
each of its ports.
There are a few general rules that are followed when a packet is
received on any port:
•If the destination address is a multicast or broadcast address,
forward the packet to all remotes.
•If the destination address is not known, forward the packet to
all remotes.
•If the destination address is known, forward the packet to the
port that the destination is known to be on (usually the RF
port).
• The bridge code uses Spanning Tree Protocol (STP) to pre-
vent loops from being created when connecting bridges in
parallel. For example, connecting two remotes to the same
wired LAN could create a loop if STP was not used. Every
bridge running STP sends out Bridge Protocol Data Units
(BPDUs) at regular intervals so that the spanning tree can be
built and maintained. BPDUs are 60-byte multicast Ethernet
frames.
2. The wireless MAC has two settings that can be adjusted.
•Fragmentation threshold is the threshold in bytes, which causes
the MAC to fragment a packet.
•RTS threshold is the threshold in bytes that causes the MAC to
use RTS/CTS before sending the packet.
3. Because of timers and other components of the protocol, there is a
maximum distance limit of 40 miles for reliable operation. Repeater
stations may be used to extend this range.
4. Throughput calculations must take into account all overhead.
The following is an example of the overhead at each layer for a
100-bytes of data over UDP:
• Data: 100 bytes
• UDP header: 8 bytes
• IP header: 20 bytes
• Ethernet header: 14 bytes
• 802.11 header 24 bytes
• LLC and SNAP header: 8 bytes
• FHSS (iNET) header and FCS: 16 bytes
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 89
Total over-the-air frame size=190 bytes
If the frame is directed (for example: not multicast/broadcast), the
802.11 ACK frame must be accounted for:
• 14 bytes—802.11 ACK
• 30 bytes—Over-the-air ACK frame (added 16 the FHSS PHY)
If the 802.11 encapsulated Ethernet frame (NOT the UDP or Ethernet
frame) exceeds the RTS threshold, then the overhead for RTS/CTS
frames must also be accounted for.
• 20 bytes—802.11 RTS.
• 14 bytes—802.11 CTS.
• 66 bytes—Total Over-the-air bytes for RTS/CTS with PHY
headers.
If the frame is TCP, then there is a 32-byte TCP header instead of the
8-byte UDP header.
•ARP requests, ARP replies and BPDU’s will affect throughput.
• ARP requests are 60-byte Ethernet frames. 142 bytes
over-the-air.
• ARP replies are 60-byte Ethernet frames. 142 bytes
over-the-air.
• BPDUs are 60-byte Ethernet frames. 142 bytes over-the-air.
Note that the overhead to put a single Ethernet frame
over-the-air is 82 bytes. If RTS/CTS is invoked, it is 148 bytes.
Therefore, the overhead for a minimal Ethernet frame
(60 bytes) is 128% and, as such, gives the transceiver a poor
small-packet performance.
If any radio in your network is connected to a large LAN, such as may
be found in a large office complex, there may be undesired multi-
cast/broadcast traffic over the air.
5. Station-to-Station Traffic
•When sending frames from an endpoint connected to one trans-
ceiver to another endpoint with a different transceiver, the
throughput will be halved at best. This is because all frames
must go through the AP and thus are transmitted twice over the
same radio system. Therefore, in the previous 100-byte UDP
example, the number of over-the-air bytes will be 380 bytes
(190 bytes x 2) if the frame has to go station-to-station.
6. Interference has a direct correlation to throughput.
• Interference could be caused by any unnecessary traffic on the
network from unrelated activities, or Radio Frequency Interfer-
ence in the wireless spectrum.
90 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Tips for Optimizing Network Performance
Here are some suggestion on things to try that may maximize
throughput:
1. AP Only: Increment the Dwell Time to the maximum of 262.1 ms.
This lowers the overhead since it will stay longer on a channel. The
down side is that if a particular channel is interfered with it will take
longer to hop to another channel.
(Main Menu>>Radio Configuration>>Dwell Time)
2. AP Only: Change the Beacon Period to Normal (508 ms). This will
also reduce the overhead of beacons sent out. On the down side,
association time may be a little longer.
(Main Menu>>Radio Configuration>>Beacon Period)
3. Change the Fragmentation Threshold to the maximum of 1600. Longer
packets will be sent over the air reducing overhead. On the down
side, if a packet is corrupted it will take longer to be retransmitted.
(Main Menu>>Radio Configuration>>Fragmentation Threshold)
4. Increase the RTS Threshold to 1600. RTS mechanism is used to
reserve a time slot if packets exceed this number. On the down side,
a hidden-node might interfere more often than if RTS is not used.
(Main Menu>>Radio Configuration>>RTS Threshold)
5. Decreasing the RTS Threshold, to the 100 to 200 range, will improve
throughput on a busy network. It will add small packets, but reduce
collisions (and resulting re-tries) of large packets.
(Main Menu>>Radio Configuration>>RTS Threshold)
6. Use the Performance Information Menu to check the packets received by
zone. (Remotes Only: Main Menu>>Performance Information>>Packet
Statistics>>Packets Received by Zone)
Readings should be close in value. A significantly lower value (2%
reduction) probably indicates interference. Performance can be
improved by blocking the affected zones at the Access Point. (Main
Menu>>Radio Configuration>>Skip Zone Option)
7. Use the Performance Information Menu to check for errors, retries and
dropped packets. Do the same with Ethernet traffic.
With weak signals, interference, or hidden nodes, the optimal per-
formance may be lower due to collisions and retries.
Data Latency—TCP versus UDP Mode
The latency of data passing through a network will depend on user data
message length, the overall level of traffic on the network, and the
quality of the radio path.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 91
Under ideal conditions—low traffic and good RF signal path—the
latency for units operating in the TCP mode, will typically be around 5
ms in each direction. However, when UDP multicast traffic is trans-
ported, the outbound packet latency (from AP to remote) is dependent
on the beacon period.
UDP multicast packet latency can be minimized by setting the Beacon
Period to Fast (52 ms). Changing beacon rate to Fast will result in an
average latency of 31 ms, assuming outbound packets wait for a beacon
transmission 50% of the time (26ms) plus the normal packet latency
(5 ms).
Data Compression
Enabling this option uses an LZO compression algorithm for
over-the-air data. Varying levels of data reduction are achieved
depending on the nature of the data. Text files are typically the most
compressible, whereas binary files are the least compressible. On
average, a 30% increase in throughput can be achieved with compres-
sion enabled.
Compression is used on data packets of 100 bytes or more, including
Ethernet, IP, and TCP/UDP headers.
3.9 MAINTENANCE
In the normal course of operating a wireless network, you will want to
take advantage of product improvements, and to read and archive the
configuration of your individual transceivers using the Maintenance
Menu. This section provides detail information on how to take advan-
tage of these services.
The maintenance tasks are:
•Reprogramming— Managing and selecting the unit’s operating
system firmware resources. (See “Reprogramming Menu” on
Page 92)
•Configuration Scripts—Saving and importing data files contain-
ing unit operating parameters/settings. (See “Configuration
Scripts Menu” on Page 97)
•Authorization Key—Alter the unit’s overall capabilities by
enabling the built-in resources. (See “Authorization Keys Menu”
on Page 105)
•Auto-Upgrade/Remote-Reboot—Configure when remotes retrieve
new firmware versions from the associated AP, and whether or
not they reboot to the new firmware after receiving the new
firmware. (See “Auto-Upgrade/Remote-Reboot Menu” on
Page 106)
•Radio Test—A diagnostic tool for testing RF operation.
(See “Radio Test Menu” on Page 107)
92 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
•Ping Utility—Diagnostic tool to test network connectivity.
(See “Ping Utility Menu” on Page 108)
Figure 3-51. Maintenance Menu
3.9.1 Reprogramming Menu
The transceiver has two copies of the firmware (microprocessor code)
used for the operating system and applications. One copy is “active” and
the second one is standing by, ready to be used. You can load new firm-
ware into the inactive position and place it in service whenever you
desire.
Figure 3-52. Reprogramming Menu
(Shown with “Image Copy” Selected)
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 93
•TFTP Host Address—IP address of the host computer from which
to get the file. [Any valid IP address] This same IP address is used
in other screens/functions (reprogramming, logging, etc.).
Changing it here also changes it for other screens/functions.
•Filename—Name of file to be received by the TFTP server.
[Any 40-character alphanumeric string] Verify that this corresponds
to the TFTP directory location. May require sub-directory, for
example: \firmware\inet\inet-4_4_0.ipk.
•TFTP Timeout—Time in seconds the TFTP server will wait for a
packet ACK (acknowledgment) from the transceiver before
suspending the file transfer. [2 to 60 seconds; 10]
•Retrieve File—Initiate the file transfer from the file from TFTP
server. Placed into inactive firmware position in the trans-
ceiver’s non-volatile memory [Y, N]
•Image Verify—Initiate the verification of the integrity of firmware
file held in unit.
•Image Copy—Initiate the copying of the active firmware into the
inactive image.
•Reboot Device—Initiate rebooting the transceiver. This will
interrupt data traffic through this unit, and the network if per-
formed on an Access Point. Intended to be used to toggle
between firmware images.
NOTE: See “Upgrading the Firmware” on Page 93 for details
on setting up the TFTP server.
Upgrading the Firmware
From time-to-time MDS offers upgrades to the transceiver firmware.
One version of the firmware provides core software resources for all
transceiver models. Loading new firmware into the unit will not alter
any privileges provided by Authorization Keys and does not require the
transceiver be taken off-line until you want to operate the unit from the
newly installed firmware image.
You must use the embedded Management System for all firmware activ-
ities, including uploading from a TFTP server.
File transfers can be initiated through any of the three Management
System gateways:
•Terminal-Emulator—Use a terminal emulator program on your
PC, such as HyperTerminal, connected directly to the trans-
ceiver’s COM1 port via a serial cable.
•Telnet—Text-based access to the Management System through
a network connection.
•Web Browser—Connect to the transceiver using a Web browser
on a local PC connected directly to the radio’s LAN port or
associated network.
94 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Firmware images are provided free-of-charge on the MDS Web site at:
www.microwavedata.com/service/technical/support
Installing New
Firmware by TFTP To install firmware by TFTP, you will need:
•A PC with a TFTP server running.
• The IP address of the PC running the TFTP server.
If you do not know your computer’s address on a Windows PC, you can
use the RUN function from the Start menu and enter winipcfg or ipconfig to
determine your local PC’s IP address. The IP address of the radio can be
found under the Management Systems’ Configuration menu.
(See “Network Configuration Menu” on Page 40.)
A TFTP server can be found on the MDS Web site at:
www.microwavedata.com/service/technical/support/downloads.asp
There are several alternatives to connecting the transceiver for firmware
upgrade. Figure 3-53 and Figure 3-54 show two variations. It is essen-
tial all of the equipment be on the same subnet.
Invisible place holder
Figure 3-53. Firmware Upgrade Setup—Option 1
(TFTP Server and Firmware File on Same CPU)
LAN COM1 COM2 PWR LINK
LAN
PORT
LOCAL WINDOWS PC
WITH iNET FILES
IP ADDRESS: 172.0.0.A
IP ADDRESS: 172.0.0.B
TFTP
SERVER
& TELNET
MDS iNET 900
C
R
O
S
S
-
O
V
E
R
C
A
B
L
E
INITIATE UPLOAD
FROM HERE
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 95
Invisible place holder
Figure 3-54. Firmware Upgrade Setup—Option 2
(TFTP Server and Firmware File on Remote Server)
NOTE: The LAN and COM1 ports share a common data channel when
loading firmware over-the-air. Transferring the radio firmware
image file (≈ 3 Mb), may take several minutes depending on
traffic between the TFTP server and the transceiver.
Regardless of your connection to the transceiver, loading firm-
ware/configuration files into the unit’s flash-RAM is much
slower than loading software onto a PC hard drive or RAM.
Upgrade Procedure To load a new firmware file (filename.ipk) into the transceiver, use the
following procedure:
1. Launch a TFTP server on a PC connected either directly or via a
LAN to the Ethernet port (LAN) of the radio. Point the server
towards the directory containing the firmware image file.
2. Connect to the Management System by whichever means is conve-
nient: Browser or Telnet via the LAN, or Terminal emulator via the
COM1 port.
3. Go to the MS Reprogramming Menu.
(Main Menu>>Maintenance Menu>>Reprogramming Menu)
4. Fill in the information for the:
•TFTP Host Address—IP Address of server (host computer) run-
ning TFTP server.
•Retrieve File—Name of file (filename.ipk) to be pulled from the
TFTP server holding the firmware file.
TFTP
SERVER ETHERNET
PORT
COM1
PORT
(DCE)
INITIATE UPLOAD
FROM HERE
REMOTE PC
W/FIRMWARE FILES
HUB/LAN/WAN/MAN
TCP/IP
LAN
PORT
COM1, 2, ETC.
(DTE)
IP ADDRESS: w.x.y.z
LOCAL WINDOWS PC
AP or REMOTE
LAN COM1 COM2 PWR LINK
IP ADDRESS: 172.0.0.A
IP ADDRESS: 172.0.0.B
TERMINAL
PROGRAM
9
-
PINS
E
R
I
A
L
C
A
B
L
E
96 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
5. Pull the firmware file through the TFTP server into the transceiver.
(Main Menu>>Maintenance Menu>>Reprogramming Menu>>Retrieve File)
Status messages on the transfer are posted on the Management Sys-
tem screen.
NOTE: The new firmware image file that replaces the “Inactive
Image” file will be automatically verified.
6. Reboot the transceiver.
Main Menu>>Maintenance Menu>>Reprogramming Menu>>Reboot Device
7. Test the transceiver for normal operation.
End of Procedure
Error Messages During File Transfers
It is possible to encounter errors during a file transfer. In most cases
errors can be quickly corrected by referring to Table 3-6.
Table 3-6. Common Errors During TFTP Transfer
Error Message Likely Cause/Corrective Action
Invalid File Type Indicates that the file is not a valid firmware
file. Locate proper file and re-load.
File not found Invalid or non-existent filename on TFTP
server
Invalid file path Invalid or non-existent file path to TFTP server
Timeout TFTP transfer time expired. Increase the
timeout value.
Flash Error Flash memory error. Contact factory for
assistance.
Bad CRC Cyclic Redundancy Check reporting a
corrupted file. Attempt to re-load, or use a
different file.
Version String Mismatch Invalid file detected. Attempt to re-load, or use
a different file.
Sending LCP Requests The PPP server is querying for any clients that
may need to connect.
Port not Enabled The serial port is disabled.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 97
3.9.2 Configuration Scripts Menu
Figure 3-55. Configuration Files Menu
•TFTP Host Address—IP address of the computer on which the
TFTP server resides. [Any valid IP address]
•Filename—Name of file containing this unit’s configuration pro-
file that will be transferred to the TFTP server. The configura-
tion information will be in a plain-text ASCII format.
[Any 40-character alphanumeric string] May require sub-directory,
for example: config\inet-config.txt. (See “Using Configuration
Scripts” on Page 98)
NOTE: The filename field is used in identifying the desired
incoming file and as the name of file being exported to the TFTP
server. Before exporting the unit’s configuration, you may want
to name it something that reflect the unit’s services or identifi-
cation.
•TFTP Timeout—Time in seconds the TFTP server will wait for a
packet ACK (acknowledgment) from the transceiver before
suspending the file transfer. [10 to 120 seconds; 10]
•Retrieve File—Initiate the file transfer of the configuration file
from TFTP server into the transceiver.
•Send File—Initiate the file transfer from the transceiver’s current
configuration file to TFTP server.
NOTE: See Upgrading the Firmware on Page 93 for details on
setting up the TFTP server.
A Brief Description of Configuration Files
If you plan to have more than a few radios in your network, use the con-
figuration file feature to configure similar units from a common set of
parameters. There are over 50 user-controllable settings that can be used
to optimize the network and saved into a Configuration File. However,
98 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
only four essential parameters need to be reviewed and altered to use the
file with another transceiver.
A Configuration File (data file) will make it easy to apply your unique
settings to any radio(s) you wish. Configuration files will also provide
you with a tool to restore parameters to a “known good” set, in the event
that a parameter is improperly set and performance is affected.
(See “Using Configuration Scripts” on Page 98 for detailed instructions
and a sample configuration file.)
Using Configuration Scripts
Configuration Scripts can be created and downloaded from the trans-
ceiver that contain a wealth of information on the unit. This file can
serve many purposes, not the least of which is to keep a permanent
“snapshot” of the unit’s configuration at a point in time. These files can
also be used to view the setup of a unit without needing to connect to it.
Examining archival files can be a useful source of information during
troubleshooting.
In the next few sections you will learn about the contents of the file and,
how to use it as a template for configuring multiple transceivers with the
same profile. Ultimately, standardized files can be uploaded into the
transceiver to speed up the installation process.
Configuration Files can also be uploaded into a transceiver to restore the
settings of a unit using a previously-saved configuration of the unit. This
is particularly convenient after finishing a test using some experimental
settings.
Sample of an Exported Configuration File
The following is a sample of a typical configuration file as produced by
a transceiver containing over 150 parameters; many of which are user
editable. The presentation has been slightly altered to allow notes to
appear below associated parameter lines. Some of the values used in the
calibration of the unit’s built-in test equipment have been deleted to
reduce space. This presentation is offered as a guide to the type of infor-
mation contained in the file. See “Editing Configuration Files” on
Page 104 for further information.
NOTE: The parameter names and the data values from the Exported
Configuration File are shown in bolded text. Any description
will be found below in an indented paragraph. Descriptions for
parameters that are functionally identical to both COM1 &
COM2 are not repeated.
Beginning of Configuration File
; MDS iNET
; Created 00-03-2002 6:59:41
IP Address: 192.168.1.1
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 99
The IPv4 address of this unit. This field is unnecessary if DHCP is
enabled.
NOTE: Changing the IP value via the network will cause a loss of
communication with other devices unaware of the new
address.
IP Netmask: 255.255.255.0
The IPv4 local subnet mask. This field is unnecessary if DHCP is
enabled.
IP Gateway: 0.0.0.0
The IPv4 address of the network gateway device, typically a router.
This field is unnecessary if DHCP is enabled.
Ethernet Address: 00:06:3D:00:00:5D
The physical Ethernet MAC (Media Access Controller) address of
the device. This value is set by the factory and cannot be changed.
Wireless Address: 00:06:3D:00:00:5C
The physical wireless MAC (Media Access Controller) address of
the device. This value is set by the factory and cannot be changed.
Model Number: 900
The model number of this unit. This value is set by the factory and
cannot be changed.
Serial Number: 1026295
The serial number of this unit. This value is set by the factory and
cannot be changed.
Unit Name: Library Admin Office
A name for this unit. It appears at the top of every menu screen.
Owner: Hilltop College IT
The name of the owner of this unit.
Contact: IT Dept. X232
The contact person regarding this unit.
Description: Link to Campus Server
A brief general description of this unit.
Location: Hollister Bldg. RM450
The location of this unit.
Com1 Port Config: 8N1
Configuration of character size, type of parity, and number of stop
bits to be used.
Com2 Port Config: 8N1
Configuration of character size, type of parity, and number of stop
bits to be used
100 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Max Remotes Allowed: 50
The maximum number of remotes allowed to connect to this Access
Point.
Device Mode: Access Point
Configures the unit to act as a Remote or an Access Point. The
Access Point option is not allowed unless the unit is specifically
ordered as such, or an Authorization Key has been purchased to
allow it.
Dwell Time: 32.8
The amount of time the unit spends at any given frequency in its
hopping pattern. This field is only changeable by an Access Point.
Remotes read the Masters value upon association.
Hop Pattern: 1
RSSH Calibration: 235
RSSL Calibration: 190
Freq Calibration: 8402
Network Name: West Campus Net
The name of the network this unit belongs to. The unit will only
communicate with devices having identical Network Names.
Date Format: Generic
Specifies the format of the date.
• Generic = dd Mmm yyyy
• European = dd-mm-yyyy
• US = mm-dd-yyyy
Console Baud: 19200
The baud rate of the serial menu console. Default value is
19200 bps.
Company Name: MDS
Version Name: 06-1234567
Product Name: iNET
Beacon Period: Normal
The amount of time in milliseconds between beacon transmissions
by the AP.
Data Rate: 512 kbps
The selected over-the-air data rate. A lower data rate generally
allows more distance between the unit and its Access Point.
RF Output Power Setpoint: 30
The desired amount of RF output power, measured in dBm.
Power Cal Table DAC1: 98
21 additional values follow; do not alter
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 101
Active Boot Image: 0
Tx Coefficient1: 0
31 additional values follow; do not alter
Rx Coefficient1: 0
14 additional values follow; do not alter
Skipped Hop Zone1: Active
Skipped Hop Zone2: Skip
Skipped Hop Zone3: Active
Skipped Hop Zone4: Active
Skipped Hop Zone5: Active
Skipped Hop Zone6: Active
Skipped Hop Zone7: Active
Skipped Hop Zone8: Active
Skipped Hop Zone9: Active
Skipped Hop Zone10: Active
Firmware TFTP Host IP: 63.249.227.105
Address of the TFTP Host from which firmware images are down-
loaded
Firmware TFTP Filename: inet-4_4_0.ipk
Eventlog TFTP Host IP: 192.168.1.3
Address of TFTP Host to which to send the event log
Eventlog TFTP Filename:
Config Script TFTP Host IP: 192.168.1.33
Address of TFTP Host to which to send the event log
Config Script TFTP Filename: inet_config.txt
Fragmentation Threshold: 1600
Maximum packet size allowed before fragmentation occurs
RTS Threshold: 500
Number of bytes for the RTS/CTS handshake boundary
RSSI Threshold: 0
RSSI value at that the connection is deemed “degraded”
SNR Threshold: 0
SNR value at that the connection is deemed “degraded”
SNMP Read Community: public
Community string for read access using SNMPv1
SNMP Write Community: private
Community string for write access using SNMPv1
SNMP Trap Community: public
102 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Community string sent with traps using SNMPv1
SNMP Trap Manager #1: 0.0.0.0
IP Address of a SNMP manager to which traps will be sent
SNMP Trap Manager #2: 0.0.0.0
SNMP Trap Manager #3: 0.0.0.0
SNMP Trap Manager #4: 0.0.0.0
SNMP Trap Manager #5: 0.0.0.0
Auth trap enable: disabled
Setting to enable SNMP authentication traps
Trap Version: v1 Traps
Selects which SNMP trap format
Package 1 Version: 1.1.0
Indicates the version of firmware in Image 1
Package 2 Version: 1.1.0
TFTP Timeout: 20
Com1 Serial Data Enable: disabled
Setting to enable COM1 data mode
Com1 Serial Data Mode: UDP
IP Protocol for COM1 data mode
Com1 Serial Data Baud Rate: 9600
Baud rate for COM1 data mode
Com1 Serial Data Tx IP Address: 0.0.0.0
COM1 data will be sent to this IP address
Com1 Serial Data Tx IP Port: 0
COM1 data will be sent to this IP port
Com1 Serial Data Rx IP Port: 0
COM1 data will be received on this IP port
Com2 Serial Data Enable: enabled
Com2 Serial Data Mode: UDP
Com2 Serial Data Baud Rate: 9600
Com2 Serial Data Tx IP Address: 169.254.10.2
Com2 Serial Data Tx IP Port: 0
Com2 Serial Data Rx IP Port: 0
Com1 Serial Data Rx IP Address: 0.0.0.0
COM1 data will be received on this IP address
Com2 Serial Data Rx IP Address: 169.254.0.2
Com2 Serial Data Flow Control: disabled
Enables hardware flow control (RTS/CTS) in COM2 data mode
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 103
SNTP Server IP: 0.0.0.0
The IPv4 address of NTP/SNTP Time Server
Com1 Serial Data Seamless Mode: enabled
Setting to enable seamless mode for COM1 data mode
Com2 Serial Data Seamless Mode: enabled
Com1 Serial Data Delimiter Chars: 4
Minimum number of characters which will be considered a gap in
seamless mode for COM1
Com2 Serial Data Delimiter Chars: 4
Com1 Serial Data Buffer Size: 20
Number of output characters which will be buffered in seamless
mode for COM1
Com2 Serial Data Buffer Size: 20
RF Frequency Hopping Format: USA/CANADA
(Read Only) The frequency-hopping rules the radio is configured to
operate under
SNMP Enable: disabled
Enable/Disable SNMP Agent
Hop Protocol: 1
Frequency hopping protocol version
DHCP Server Enable: disabled
Enable/Disable DHCP Server Daemon
DHCP Netmask: 255.255.255.0
The IP Address to be used as the DHCP Netmask
DHCP Start Address: 192.168.0.11
The IP Address to be used as the starting address
DHCP End Address: 192.168.0.22
The IP Address to be used as the ending address
Approved Remotes List Enable: disabled
Setting to enable the Approved Remotes List
Encryption Enable: disabled
Setting to enable over-the-air data encryption
HTTP Enable: enabled
Setting to enable the HTTP interface
Telnet Enable: enabled
Setting to enable the Telnet interface
HTTP MD5 Authentication: disabled
104 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Setting to enable MD5 Digest Authentication
Automatic Key Rotation: disabled
Setting to enable Automatic Key Rotation
Approved APs List Enable: disabled
Setting to enable the Approved Access Points List
Watch-Link-Status Flag @ AP: disabled
A flag that controls whether the Remotes care about the AP's Ether-
net Link Status
Network Name Hash Enable: disabled
A flag that controls whether MD5 hashing is applied to the network
name
End of Configuration File
Editing Configuration Files
Once a Remote unit’s operation is fine-tuned, use the Configuration
Scripts Menu on Page 97 to save a copy of the configuration in a PC.
Once the file is saved in the PC it can be used as a source to generate
modified copies adjusted to match other devices. The configuration files
can be modified using a text editor or an automated process. (Not pro-
vided by MDS).
We recommend that you review and update the following parameters for
each individual unit. Other parameters may also be changed.
Table 3-7. Common User-Alterable Parameters
Field Comment Range
IP Address Unique for each individual radio Any legal IP address
IP Gateway May change for different groups or
locations
Any legal IP address
Unit Name Should reflect a specific device.
This information will appear in
Management System headings
Any 20-character
alphanumeric string
Location Used only as reference for network
administration
Any 40-character
alphanumeric string
System Mode The application of the parameter in
this field is dependent on the
authorized options stored in the
unit’s permanent memory.
The mode must be compatible with
any previously installed
Authorization Keys.
“Access Point”
“Dual Remote”
“Serial Remote”
“Ethernet Remote”
NOTE: These are
case-sensitive.
Network Name Used to identify different groups or
locations
Any 15-character
alphanumeric string
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 105
Each resulting file should be saved with a different name. We recom-
mend using directories and file names that reflect the location of the unit
to facilitate its identification.
Editing Rules • You may include only parameters you want to change.
• Change only the parameter values.
• Capitalization counts in some field parameters.
(Example: System Mode)
• Comment Fields
a. Edit, or delete anything on each line to the right of the
comment delineator, the semicolon (;).
b. Comments can be of any length, but must be on the same
line as the parameter, or on a new line that begins with a
semicolon character.
c. Comments after parameters in files exported from a trans-
ceiver do not need to be present in your customized files.
3.9.3 Authorization Keys Menu
Figure 3-56. Authorization Key Menu
•Authorization Key—Initiate the entering of an Authorization Key
into the transceiver’s non-volatile memory.
•Authorized Features—List of authorized features.
In addition to the four configurations fields, is the MDS NETview
MS access control. NETview MS is designed to help users mon-
itor system performance, configure network elements, detect
faults and correct problems in the convenience of an office set-
ting or at any other point in the network.
106 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
3.9.4 Auto-Upgrade/Remote-Reboot Menu
NOTE: This menu is only available when MDS NETview MS key is
enabled.
Invisible place holder
Figure 3-57. Auto-Upgrade / Remote Reboot Menu
•Auto Upgrade—Causes all of the Remotes associated to this AP
to read the AP’s newest firmware version (active or inactive)
and upload it via TFTP to the inactive image, but only if it is
newer than the Remote’s current firmware.
•Reboot on Upgrade—Determines how a Remote will behave once
it has uploaded new firmware from the AP as part of an
auto-upgrade. When enabled, the Remote will reboot to the new
firmware.
•Force Reboot—Causes all of the Remotes associated to this AP
to reboot immediately. They will reboot to their current active
image—the same as if the power were re-cycled.
NOTE: To use the Auto Upgrade/Reboot feature, both the AP and
Remotes must already be running version 4.4.0 or newer firm-
ware.
Exception: If the AP has already been upgraded to version
4.4.0 and the Remote is still at 3.5.0 or older, you can upgrade
the Remote by using the AP as a file server. This method
allows for only one remote to be upgraded at a time. Instruc-
tions for this method are given below.
Firmware Upgrade (with AP Acting as a File Server)
An AP running firmware version 4.4.0 (or newer) may be used as a file
server to upgrade Remotes running older firmware (3.5.0 or earlier).
Follow the steps below to perform the upgrade:
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 107
1. At the Reprogramming Menu (Page 92), Enter the AP’s IP Address
in the TFTP Server field.
2. Enter upgrade_from_ap.ipk in the Filename field.
NOTE: The filename is case sensitive.
3. Perform the firmware download.
3.9.5 Radio Test Menu
This area provides several useful tools for installers and maintainers.
You can manually key the radio transmitter to make measurements of
antenna performance. (See “Antenna Aiming” on Page 125 for details.)
Figure 3-58. Radio Test Menu
Shown with Test Mode set to ON
NOTE : Use of the Test Mode will disrupt traffic through the radio. If
the unit is an Access Point, it will disrupt traffic through the
entire network.
Test Mode function is automatically limited to 10 minutes and
should only be used for brief measurement of transmit power.
It may also be manually reset to continue with the testing or
turned off.
•Test Mode—Controls access to the transceiver’s suite of tools.
[ON, OFF; OFF]
•Frequency—Set radio operating frequency during the testing
period to a single frequency. [915.0000 MHz]
•TX Output Power—Temporarily overrides the power level set-
ting in the Radio Configuration Menu. [20]
108 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
•TxKey—Manually key the radio transmitter for power mea-
surements. [Enable, Disable; Disable]
•RSSI—Incoming received signal strength on frequency
entered in the frequency parameter on this screen (–dBm).
This RSSI measurement is updated more frequently than the
RSSI by Zone display of the Performance Information menu.
3.9.6 Ping Utility Menu
Figure 3-59. Ping Utility Menu
•IP Addr—Address to send a PING. [Any valid IP address]
•Count—Number of PING packets to be sent.
•Packet Size—Size of each PING data packet (bytes).
•Go—Send PING packets to address shown on screen.
Screen will be replaced with detailed report of PING activity.
Press any key after viewing the results to return to this menu.
3.9.7 Reset to Factory Defaults
To reset all transceiver parameters back to the factory defaults, you must
enter a special code (authorization key) provided by the factory in place
of the user name.
This procedure is useful when several parameters have been modified,
and there is no track of changes. The transceiver returns to a known
state, where it may be easier to determine the correct settings.
3.9.8 Resetting the Password
The user has the ability to return the iNET password to the default value
of admin by entering a specific MDS-supplied authorization key at the
login prompt. This event causes all radio parameters to return to the fac-
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 109
tory default settings. Because of this, if the person requesting the pass-
word-reset authorization key is not the true owner, any custom
configuration settings from the true owner are erased. This prevents the
new person from recovering the network settings of the true owner.
110 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 111
4 TROUBLESHOOTING &
RADIO MEASUREMENTS
4 Chapter Counter Reset Paragraph
Contents
4.1 TROUBLESHOOTING .............................................................
113
4.1.1 Interpreting the Front Panel LEDs ............................................ 113
4.1.2 Troubleshooting Using the Embedded Management System .. 114
4.1.3 Using Logged Operation Events .............................................. 118
4.1.4 Alarm Conditions ...................................................................... 118
4.1.5 Correcting Alarm Conditions .................................................... 120
4.1.6 Logged Events ......................................................................... 121
4.2 RADIO (RF) MEASUREMENTS............................................. 123
4.2.1 Antenna System SWR and Transmitter Power Output ............. 124
4.2.2 Antenna Aiming ........................................................................ 125
112 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 113
4.1 TROUBLESHOOTING
Successful troubleshooting of a wireless system is not difficult, but
requires a logical approach. It is best to begin troubleshooting at the
Access Point unit, as the rest of the system depends on the Access Point
for synchronization data. If the Access Point has problems, the operation
of the entire wireless network will be affected.
When communication problems are found, it is good practice to begin
by checking the simple things. Applying basic troubleshooting tech-
niques in a logical progression can identify many problems.
Multiple
Communication
Layers
It is important to remember the operation of the network is built upon a
radio communications link. On top of that are two data levels— wireless
MAC, and the data layer. It is essential that the wireless aspect of the
Access Point and the Remotes units to be associated are operating prop-
erly before data-layer traffic will function.
Unit Configuration There are over 50 user-configurable parameters in the Management
System. Do not overlook the possibility that human error may be the
cause of the problem. With so many possible parameters to look at and
change, a parameter may be incorrectly set, and then what was changed
is forgotten.
To help avoid these problems, we recommend creating an archive of the
transceiver’s profile when your installation is complete in a Configura-
tion File. This file can be reloaded into the transceiver to restore the unit
to the factory defaults or your unique profile. For details on creating and
archiving Configuration Files, see “Using Configuration Scripts” on
Page 98.
Factory Assistance If problems cannot be resolved using the guidance provided here,
review the MDS web site’s technical support area for recent soft-
ware/firmware updates, general troubleshooting help, and service infor-
mation. Additional help is available through our Technical Support
Department. (See “TECHNICAL ASSISTANCE” on the inside of the
rear cover.)
4.1.1 Interpreting the Front Panel LEDs
An important set of troubleshooting tools are the LED status indicators
on the front panel of case. You should check them first whenever a
problem is suspected. Table 2-2 on Page 23 describes the function of
each status LED. Table 4-1 below provides suggestions for resolving
114 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
common system difficulties using the LEDs, and Table 4-2 provides
other simple techniques.
4.1.2 Troubleshooting Using the Embedded
Management System
If you have reviewed and tried the things mentioned in Table 4-1 and
still have not resolved the problem, there are some additional tools and
techniques that can be used. The embedded Management System is a
good source of information that may be used remotely to provide pre-
liminary diagnostic information, or may even provide a path to cor-
recting the problem.
Table 4-1. Troubleshooting Using LEDs—Symptom-Based
Symptom Problem/Recommended System Checks
PWR LED does not
turn on
a. Voltage too low—Check for the proper supply voltage at
the power connector. (10–30 Vdc)
b. Indefinite Problem—Cycle the power and wait
(≈ 30 seconds) for the unit to reboot. Then, recheck for
normal operation.
LINK LED does not
turn on
a. Network Name of Remote not identical to desired Access
Point—Verify that the system has a unique Network Name.
b. Not yet associated with an Access Point with the same
Network Name.
Check the “Status” of the unit’s process of associating with
the Access Point. Use the Management System.
c. Poor Antenna System—Check the antenna, feedline and
connectors. Reflected power should be less than 10% of
the forward power reading (SWR 2:1 or lower).
PWR LED is
blinking
a. Blinking indicates an alarm condition exists.
b. View Current Alarms and Event Log and correct the
problem if possible.
(See “Using Logged Operation Events” on Page 118)
c. Blinking will continue until the source of the alarm is
corrected, for example, a valid IP address is entered, etc.
LAN LED does not
turn on
a. Verify the Ethernet cable is connect at both ends.
b. Verify that the appropriate type of Ethernet cable is used:
straight-through, or crossover.
LAN LED lights, but
turns off after some
time
Verify traffic in LAN. Typically, the radio should not be placed
in high traffic enterprise LANs, as the it will not be able to pass
this level of traffic. If needed, use routers to filter traffic.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 115
Table 4-2. Basic Troubleshooting Using the Management System
Symptom Problem/Recommended System Checks
Remote does not
associate; stays in
HOPSYNC
a. Verify the AP has sufficiently large number in the “Max
Remotes” parameter of the Network Configuration Menu.
b. Verify the correct MAC address is listed in the “Approved
Remotes List” or “Approved Access Points List” of the
Security Configuration menu.
Serial data is slow
with UDP multicast
traffic
Change Beacon Period to FAST.
(Radio Configuration Menu)
Cannot access the
MS through COM1
a. Connect to unit via Telnet or Web browser
b. Disable the serial mode for COM1
(Serial Gateway Configuration>>Com1 Serial Data
Port>>Status>>Disabled)
or, if you know the unit’s data configuration:
a. Connect to COM 1 via a terminal set to VT100 and the
port’s data baud rate.
b. Type +++
c. Change the terminal’s baud rate to match the transceiver’s
Console Baud Rate.
d. Type +++
Display on
terminal/Telnet
screen garbled
Verify the terminal/terminal emulator or Telnet application is
set to VT100
Cannot pass IP
data to WAN.
a. Verify your IP settings.
b. Use the PING command to test communication with the
transceivers in the local radio system.
c. If successful with local PING, attempt to PING an IP unit
attached to a transceiver.
d. If successful with the LAN PINGs, try connecting to a
known unit in the WAN.
Wireless Retries
too high.
Possible Radio Frequency Interference—
a. If omnidirectional antennas are used, consider changing to
directional antennas. This will often limit interference to
and from other stations.
b. Try skipping some zones where persistent interference is
known or suspected.
c. The installation of a filter in the antenna feedline may be
necessary. Consult the factory for further assistance.
Password
forgotten.
a. Connect to the transceiver using a terminal through the
COM1 Port.
b. Obtain a password-resetting Authorization Key from your
factory representative.
c. Enter the Authorization Key at the login prompt as a
password.
Packet Repeat
Mode troubles
(extra characters in
data, data not
delivered)
Verify that all radios in the network have their Packet
Redundancy Mode set to the same selection (Single Packet
vs. Packet Repeat Mode).
116 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
The following is a summary of how several screens in the Management
System can be used as diagnostic tools. For information on how to con-
nect to the Management System See “STEP 3—CONNECT PC TO THE
TRANSCEIVER” on Page 20.
Starting Information Screen
(See Starting Information Screen on Page 36)
The Management System’s “homepage” provides some valuable bits of
data. One of the most important is the “Device Status” field. This item
will tell you if the unit is showing signs of life.
If the Device Status field says “associated,” then look in the network
areas beginning with network data statistics. If it displays some other
message, such as Scanning, Hop Sync or Alarmed, you will need to
determine why it is in this state.
The Scanning state indicates a Remote unit is looking for an Access
Point beacon signal to lock onto. It should move to the Hop Sync and
finally to the Associated state within less than a minute. If this Remote
unit is not providing reliable service, look at the Event Logs for signs of
lost association with the Access Point or low signal alarms. Table 4-3
provides a description of the Device Status messages.
If the Remote is in an “Alarmed” state, the unit may still be operational
and associated. Look for the association state in the Wireless Network
Status screen to determine if the unit is associated. If it is, then look at
the Error Log for possible clues.
If the unit is in an “Alarmed” state and not able to associate with an
Access Point unit, then there may be problem with the wireless network
layer. Call in a radio technician to deal with wireless issues. Refer the
technician to the RADIO (RF) MEASUREMENTS on Page 123 for infor-
mation on antenna system checks.
Table 4-3. Device Status1
1. Available in the Startup Information Screen or the Wireless Status Screen at
the Remotes.
Scanning The unit is looking for an Access Point beacon signal. If
this is a Remote radio, Associated means that this unit is
associated with an Access Point
Hop Sync The unit has found a valid beacon signal for its network
and has changed its frequency hopping pattern to match
that of the AP.
Associated This unit has successfully synchronized and is
“associated” with an Access Point. This is the normal
operating state.
Alarmed The unit is has detected one or more alarms that have not
been cleared.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 117
Packet Statistics Menu
(See Packet Statistics Menu on Page 81)
This screen provides detailed information on data exchanges between
the unit being viewed and the network through the wireless and the
Ethernet (data) layers. These include:
The most significant fields are the Packets Dropped, Retries, Retry
Errors, Receive Errors and Lost Carrier Detected. If the data values are
more than 10% of their sent and received counterparts, or the Lost Car-
rier Detected value is greater than a few dozen, there may be trouble
with radio-frequency interference or a radio link of marginal strength.
Review the RSSI by Zone Screen’s values (Page 77) for zones that are
more than 2 dB (decibels) below the average level, and for signal level
values that are likely to provide marginal service. For example, an
average level is less than –85 dBm during normal conditions with a data
rate of 256 kbps.
If the RSSI levels in each zone are within a few dB of each other, but
less than –85 dBm, then a check should be made of the aiming of the
antenna system and for a satisfactory SWR. Refer to RADIO (RF) MEA-
SUREMENTS on Page 123 for information on antenna system checks.
NOTE: For a data rate of 512 kbps, the average signal level should be
–77 dBm or stronger with no interference.
Serial Port Statistics Menu
(See Serial Data Statistics Menu on Page 87)
This screen provides top-level information on data exchanges between
the unit’s serial ports and the network through the wireless and the
Ethernet (data) layers. These include:
Wireless Packet Statistics
• Packets received • Packets dropped
• Packets sent • Receive errors
• Bytes received • Retries
• Bytes sent • Retry errors
Ethernet Packet Statistics
• Packets received • Packets dropped
• Packets sent • Receive errors
• Bytes received • Retries
• Bytes sent • Retry errors
• Lost carrier detected
• Bytes In On Port xxx • Bytes In On Socket xxx
• Bytes Out On Port xxx • Bytes Out On Socket xxx
118 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
You can use this screen as a indicator of port activity at the data and IP
levels.
Diagnostic Tools
(See MAINTENANCE on Page 91)
The radio’s Maintenance menu contains two tools that are especially
useful to network technicians—the Radio Test Menu and the Ping
Utility. The Radio Test selection allows for testing RF operation, while
the Ping Utility can be used to verify reachability to pieces of equipment
connected to the radio network. This includes transceivers and user-sup-
plied Ethernet devices.
4.1.3 Using Logged Operation Events
(See Event Log Menu on Page 78)
The transceiver’s microprocessor monitors many operational parame-
ters and logs them as various classes of “events”. If the event is one that
affects performance, it is an “alarmed”. There are also normal or routine
events such as those marking the rebooting of the system, implementa-
tion of parameter changes and external access to the Management
System. Informational events are stored in temporary (RAM) memory
that will be lost in the absence of primary power, and Alarms will be
stored in permanent memory (Flash memory) until cleared by user
request. Table 3-5 summarizes these classifications.
These various events are stored in the transceiver’s “Event Log” and can
be a valuable aid in troubleshooting unit problems or detecting attempts
at breaching network security.
4.1.4 Alarm Conditions
(See View Current Alarms on Page 80)
Most events, classified as “critical” will make the PWR LED blink, and
will inhibit normal operation of the transceiver. The LED blinks until
the corrective action is completed.
Table 4-4. Event Classifications
Level Description/Impact Storage
Informational Normal operating activities Flash
Memory
Minor Does not affect unit operation RAM
Major Degraded unit performance but
still capable of operation
RAM
Critical Prevents the unit from operating RAM
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 119
Table 4-5. Alarm Conditions (Alphabetical Order)
Alarm Condition Reported Event Log Entry SNMP Trap
EVENT_50_LIMIT Crossed 50% of Eth
Port Rate Limit
rateLimit50(20)
EVENT_75_LIMIT Crossed 75% of Eth
Port Rate Limit
rateLimit75(21)
EVENT_100_LIMIT Crossed 100% of Eth
Port Rate Limit
rateLimit100(22)
EVENT_ADC ADC output Railed adcInput(3)
EVENT_AP_NN_CHANGED Network Name changed
at the AP
apNetNameChanged(74)
EVENT_BRIDGE Network Interface /Error networkInterface(17)
EVENT_CHILE_CHAN_CNT Mismatch in Chilean
Channel count at
AP/REM
chileChanCnt(71)
EVENT_CHILE_NO_CHAN Using Chilean hopping
but no channels
selected
chileNoChan(23)
EVENT_COMPRESS Compression setting
changed
compressionChanged(76)
EVENT_ENDPOINT Endpoint
Added/Removed (AP
only)
eventEndpoint(67)
EVENT_ETH_LINK_AP* AP Ethernet Link
Disconnected
apEthLinkLost(19)
EVENT_FLASH_TEST Flash Test Failed -
EVENT_FPGA FPGA communication
Failed
fpgaCommunication(2)
EVENT_FREQ_CAL Frequency Not
Calibrated
frequencyCal(7)
EVENT_INIT_ERR Initialization Error initializationError(18)
EVENT_IPADDR*IP Address Invalid ipAddressNotSet(4)
EVENT_IP_CONN(OK) ipConnectivityOK(75)
EVENT_IPMASK*IP Mask Invalid ipNetmaskNotSet(5)
EVENT_LAN_PORT lanPortStatus(78)
EVENT_MAC MAC communication
Failed
macCommunication(1)
EVENT_MACADDR MAC Address Invalid noMacAddress(6)
EVENT_NETNAME*Netname Invalid invalidNetname(12)
EVENT_PLL_LOCK PLL Not locked pllLock(10)
EVENT_POWER_CAL Power Calibrated/Not
Calibrated
powerCal(8)
EVENT_POWER_HIGH RF Power Control
Saturated High
rfPowerHigh(13)
EVENT_POWER_LOW RF Power Control
Saturated Low
rfPowerLow(14)
120 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
* Condition may be corrected by user and alarm cleared.
4.1.5 Correcting Alarm Conditions
(See View Event Log on Page 81)
Table 4-6 provides insight on the causes of events that inhibit the unit
from operating, and possible corrective actions. The Event Description
column appears on the Event Log screen.
EVENT_REMOTE Remote Added/
Removed (AP only)
eventRemote(66)
EVENT_REPETITIVE The previous event is
occurring repetitively
EVENT_ROUTE_ADD Manual entry added to
Routing table
routeAdded(68)
EVENT_ROUTE_DEL Manual entry deleted
from Routing table
routeDeleted(69)
EVENT_RSSI*RSSI Exceeds
threshold
rssi(11)
EVENT_RSSI_CAL RSSI Not Calibrated rssiCal(9)
EVENT_SDB_ERR Internal
Remote/Endpoint
database error (AP
only)
sdbError(80)
EVENT_SINREM_SWITCH Eth/Serial mode switch
in a Single Remote
sinRemSwitch(70)
EVENT_SYSTEM_ERROR* System Error Cleared;
Please Reboot
systemError(16)
EVENT_TFTP_CONN TFTP connectivity
achieved
tftpConnection(73)
EVENT_TFTP_ERR Attempted TFTP
connection failed
tftpConnFailed(79)
Table 4-5. Alarm Conditions (Alphabetical Order) (Continued)
Alarm Condition Reported Event Log Entry SNMP Trap
Table 4-6. Correcting Alarm Conditions—Alphabetical Order
Event Log Entry Generating Condition Clearing Condition
or Action
ADC Failure The ADC always reads the
same value (either high or
low limit)
Contact factory Technical
Services for assistance
AP Ethernet Link Monitor will check state of
Ethernet link and set alarm if
it finds the link down
Ethernet link is re-established
Bridge Down When the Bridge fails to be
initialized
Contact factory Technical
Services for assistance
Flash Test Failed Internal check indicates
corruption of Flash memory
Contact factory Technical
Services for assistance
FPGA Failure Communication lost to the
FPGA
Contact factory Technical
Services for assistance
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 121
4.1.6 Logged Events
(See View Event Log on Page 81)
The following events allow the transceiver to continue operation and do
not make the PWR LED blink. Each is reported through an SNMP trap.
General System
Error
Internal checks suggest unit
is not functioning properly
Reboot the transceiver
Initialization Error Unit fails to complete boot
cycle
Contact factory Technical
Services for assistance
Invalid IP Address The IP address is either
0.0.0.0 or 127.0.0.1
Program IP address to
something other than 0.0.0.0
or 127.0.0.1
MAC Failure The monitor task reads the
LinkStatus from the MAC
every second. If the MAC
does not reply 10
consecutive times
(regardless of what the result
is) the CPU assumes the
transceiver has lost
communication to the MAC.
Contact factory Technical
Services for assistance
Network Interface
Error
Unit does not recognize the
LAN interface
Contact factory Technical
Services for assistance
Network Name Not
Programmed
Network name is “Not
Programmed”
Change Network Name to
something other than “Not
Programmed”
PLL Out-of-Lock The FPGA reports a
synthesizer out-of-lock
condition when monitored by
the CPU.
Contact factory Technical
Services for assistance.
Power Control
Railed High
Power control can no longer
compensate and reaches the
high rail
Contact factory Technical
Services for assistance
Power Control
Railed Low
Power control can no longer
compensate and reaches the
low rail
Contact factory Technical
Services for assistance
RSSI Exceeds
Threshold
The running-average RSSI
level is weaker (more
negative) than the
user-defined value.
Check aiming of the
directional antenna used at
the Remote; or raise the
threshold level to a stronger
(less-negative) value.
Table 4-6. Correcting Alarm Conditions—Alphabetical Order
Event Log Entry Generating Condition Clearing Condition
or Action
122 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
The left hand column, “Event Log Entry” is what will be shown in the
Event Log.
Table 4-7. Non-Critical Events—Alphabetical Order
Event Log Entry Severity Description
Association Attempt
Success/Failed
MAJOR Self explanatory
Association Lost - AP Hop
Parameter Changed
MINOR Self explanatory
Association Lost - AP's
Ethernet Link Down
MAJOR Self explanatory
Association Lost - Local IP
Address Changed
MAJOR Self explanatory
Association Lost - Local
Network Name Changed
MAJOR Self explanatory
Association Lost/Established MAJOR Self explanatory
Auth Demo Mode Expired --
Rebooted Radio/Enabled
MAJOR Self explanatory
Auth Key Entered - Key
Valid/Key Invalid
MAJOR Self explanatory
Bit Error Rate Below
threshold/Above threshold
INFORM Self explanatory
Console Access Locked for
5 Min
MAJOR Self explanatory
Console User Logged
Out/Logged In
MAJOR Self explanatory
Country/SkipZone Mismatch INFORM Self explanatory
Current AP No Longer
Approved
MAJOR May occur during the Scanning
process at a remote. Indicates that
the received beacon came from an
AP which is not in the “Approved
AP” list. This may be caused by
some remotes hearing multiple
AP's. This event is expected
behavior.
Decryption Error/Decryption
OK
A decryption error is logged when
an encryption phrase mismatch
has occurred. A mismatch is
declared after five consecutive
errors over a 40-second window.
When the error has cleared,
DECRYPT OK will appear.
Desired AP IP Addr Mismatch INFORM Self explanatory
ETH Rate Indicates heavy bursts of traffic on
the unit's Ethernet port (LAN). This
is expected behavior, resulting
from the network configuration.
Ethernet Port
Enabled/Disabled
INFORM Self explanatory
Expected Sync
Lost/Established
INFORM Self explanatory
Hop Sync Lost/Established INFORM Self explanatory
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 123
4.2 RADIO (RF) MEASUREMENTS
There are several measurements that are a good practice to perform
during the initial installation. The will confirm proper operation of the
unit and if they are recorded, serve as a benchmark in troubleshooting
should difficulties appear in the future. These measurements are:
• Transmitter Power Output
• Antenna System SWR (Standing-Wave Ratio)
Hop Table
Generated/Generation Failed
INFORM Self explanatory
HTTP Access Locked for 5 Min MAJOR Self explanatory
HTTP User Logged
Out/Logged In
MAJOR httpLogin(49)
Log Cleared INFORM Self explanatory
MAC Param Changed Caused by remotes running in auto
data rate mode. Every time the link
conditions cause a data rate
change, the remote’s MAC
changes to the new rate and
forwards a signal to the AP. This
indicates link quality is changing
and causing the data rate to adjust
accordingly.
Max Beacon Wait Time
Exceeded
MAJOR Self explanatory
Received Beacon - AP is
Blacklisted
INFORM Self explanatory
Received Beacon - Netname
Does Not Match
INFORM Self explanatory
Received Beacon -
Valid/Errored
INFORM Self explanatory
Rem Ethernet Link
Connected/Disconnected
MAJOR Self explanatory
Reprogramming Complete INFORM Self explanatory
Reprogramming Failed MAJOR Self explanatory
Reprogramming Started INFORM Self explanatory
Scanning Started INFORM Self explanatory
SNR Within threshold/Below
threshold
INFORM Self explanatory
System Bootup (power on) INFORM Self explanatory
Telnet Access Locked for
5 Min
MAJOR Self explanatory
Telnet User Logged
Out/Logged In
MAJOR Self explanatory
User Selected Reboot MAJOR Self explanatory
Table 4-7. Non-Critical Events—Alphabetical Order (Continued)
Event Log Entry Severity Description
124 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
• Antenna Direction Optimization
These procedures may interrupt traffic through an established network
and should only be performed by a skilled radio-technician in coopera-
tion with the network manager.
4.2.1 Antenna System SWR and Transmitter Power
Output
Introduction
A proper impedance match between the transceiver and the antenna
system is important. It ensures the maximum signal transfer between the
radio and antenna. The impedance match can be checked indirectly by
measuring the SWR (standing-wave ratio) of the antenna system. If the
results are normal, record them for comparison for use during future
routine preventative maintenance. Abnormal readings indicate a pos-
sible trouble with the antenna or the transmission line that will need to
be corrected.
The SWR of the antenna system should be checked before the radio is
put into regular service. For accurate readings, a wattmeter suited to
1000 MHz measurements is required. One unit meeting this criteria is
the Bird Model 43™ directional wattmeter with a 5J element installed.
The reflected power should be less than 10% of the forward power
(≈2:1 SWR). Higher readings usually indicate problems with the
antenna, feedline or coaxial connectors.
If the reflected power is more than 10%, check the feedline, antenna and
its connectors for damage.
Record the current transmitter power output level, and then set it to
30 dBm for the duration of the test to provide an adequate signal level
for the directional wattmeter.
Procedure
1. Place a directional wattmeter between the ANTENNA connector and
the antennas system.
2. Place the transceiver into the Radio Test Mode using the menu
sequence below:
(Main Menu>>Maintenance Menu>>Radio Test>>Test Mode>>Y>>ON)
NOTE: The Test Mode has a 10-minute timer, after which it will return
the radio to normal operation. The Radio Test Mode can be
terminated manually by selecting OFF on the menu or tempo-
rarily disconnecting the radio’s DC power.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 125
3. Set the transmit power to 30 dBm. (This setting does not affect the
output level during normal operation—only during Test Mode.)
(Main Menu>>Maintenance Menu>>Radio Test>>Test Mode>>Tx Power Out-
put)
4. Key the transmitter.
(Main Menu>>Maintenance Menu>>Radio Test>>Test Mode>>TxKey>>
Enable)
Use the PC’s spacebar to key and unkey the transmitter ON and
OFF. (Enable/Disable)
5. Measure the forward and reflected power into the antenna system
and calculate the SWR and power output level. The output should
agree with the programmed value.
(Main Menu>>Radio Configuration>>RF Power Output)
6. Turn off Radio Test Mode at the Access Point and Remote.
(Main Menu>>Maintenance Menu>>Radio Test>>Test Mode>>Disable)
End of procedure
4.2.2 Antenna Aiming
Introduction
The radio network integrity depends, in a large part, on stable radio
signal levels being received at each end of a data link. In general, signal
levels stronger than –77 dBm (–80 dBm for iNET II) provides
the basis for reliable communication that includes a 15 dB fade margin.
As the distance between the Access Point and Remotes increases, the
influence of terrain, foliage and man-made obstructions become more
influential and the use of directional antennas at Remote locations
becomes necessary. Directional antennas usually require some
fine-tuning of their bearing to optimize the received signal strength. The
transceiver has a built-in received signal strength indicator (RSSI) that
can be used to tell you when the antenna is in a position that provides
the optimum received signal.
RSSI measurements and Wireless Packet Statistics are based on mul-
tiple samples over a period of several seconds. The average of these
measurements will be displayed by the Management System.
The measurement and antenna alignment process will usually take 10 or
more minutes at each radio unit.
The path to the Management System menu item is shown in bold text
below each step of the procedure.
126 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Procedure
1. Verify the Remote transceiver is associated with an Access Point
unit by observing the condition of the LINK LED (LINK LED = On or
Blinking). This indicates that you have an adequate signal level for
the measurements and it is safe to proceed.
2. View and record the Wireless Packets Dropped and Received Error
rates.
(Main Menu>>Performance Information>>Packet Statistics>>Wireless Packet
Statistics)
This information will be used later.
3. Clear the Wireless Packets Statistics history.
(Main Menu>>Performance Information>>Packet Statistics>>Wireless Packet
Statistics>>Clear Wireless Stats)\
4. Read the RSSI level at the Remote.
(Main Menu>>Performance Information>>RSSI by Zone)
5. Optimize RSSI (less negative is better) by slowly adjusting the
direction of the antenna.
Watch the RSSI indication for several seconds after making each
adjustment so that the RSSI accurately reflects any change in the
link signal strength.
6. View the Wireless Packets Dropped and Received Error rates at the
point of maximum RSSI level. They should be the same or lower
than the previous reading.
(Main Menu>>Performance Information>>Packet Statistics>>Wireless Packet
Statistics)
If the RSSI peak results in an increase in the Wireless Packets
Dropped and Received Error, the antenna may be aimed at an undes-
ired signal source. Try a different antenna orientation.
End of procedure
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 127
5PLANNING A RADIO
NETWORK
5 Chapter Counter Reset Paragraph
Contents
5.1 INSTALLATION PLANNING.....................................................129
5.1.1 General Requirements ............................................................. 129
5.1.2 Site Selection ...........................................................................131
5.1.3 Terrain and Signal Strength ...................................................... 131
5.1.4 Antenna & Feedline Selection .................................................. 132
5.1.5 How Much Output Power Can be Used? .................................135
5.1.6 Conducting a Site Survey .........................................................135
5.1.7 A Word About Radio Interference ............................................ 136
5.2 dBm-WATTS-VOLTS CONVERSION CHART .........................139
128 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 129
5.1 INSTALLATION PLANNING
This section provides tips for selecting an appropriate site, choosing an
antenna system, and reducing the chance of harmful interference.
5.1.1 General Requirements
There are three main requirements for installing a transceiver—ade-
quate and stable primary power, a good antenna system, and the correct
interface between the transceiver and the data device. Figure 5-1 shows
a typical Remote Gateway installation.
NOTE: The iNET 900 network port supports 10BaseT connections,
but does not support 100BaseT connections. This should not
present a problem because most hubs/switches auto-switch
between 10BaseT and 100BaseT connections. Confirm that
your hub/switch is capable of auto-switching data rates.
To prevent Ethernet traffic from degrading iNET 900 perfor-
mance, place the iNET in a segment, or behind routers.
Invisible place holder
Figure 5-1. Typical Installation with a Tower-Mounted Antenna
(Connect user data equipment to any compatible LAN or COM Port)
Unit Dimensions
Figure 5-2 shows the dimensions of the transceiver case and its
mounting holes, and Figure 5-3 on Page 131, the dimensions for
mounting with factory-supplied brackets. If possible, choose a mounting
POWER SUPPLY
13.8 VDC @ 580 mA (Max.)
(10.5–30 Vdc)
Negative Ground Only
COMPUTER
W/TERMINAL
EMULATOR
TRANSCEIVER
LOW-LOSS FEEDLINE
ANTENNA
SYSTEM
DATA TERMINAL
EQUIPMENT OR
LAN/WAN
Network
130 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
location that provides easy access to the connectors on the end of the
radio and an unobstructed view of the LED status indicators.
Figure 5-2. Transceiver Dimensions
4.25˝ (10.8 cm)
4.75˝ (12.0 cm)
1.4˝ (3.56 cm)
6.75˝ (17.15 cm)
4.5˝ (11.43 cm)
TOP
SIDE
BOTTOM
2.5˝ (6.35 cm)
4.85˝ (12.32 cm)
THREADED
HOLES FOR
MOUNTING
SCREWS (4)
#6-32 X 1/4˝ LONG
Not to scale
FRONT
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 131
Invisible place holder
Invisible place holder.
Figure 5-3. Mounting Bracket Dimensions
5.1.2 Site Selection
Suitable sites should provide:
• Protection from direct weather exposure
•A source of adequate and stable primary power
• Suitable entrances for antenna, interface or other required
cabling
• Antenna location that provides as unobstructed a transmission
path as possible in the direction of the associated station(s)
These requirements can be quickly determined in most cases. A possible
exception is the last item—verifying that an unobstructed transmission
path exists. Radio signals travel primarily by line-of-sight, and obstruc-
tions between the sending and receiving stations will affect system per-
formance. If you are not familiar with the effects of terrain and other
obstructions on radio transmission, the discussion below will provide
helpful background.
5.1.3 Terrain and Signal Strength
While the license-free 900 MHz band offers many advantages for data
transmission services, signal propagation is affected by attenuation from
obstructions such as terrain, foliage or buildings in the transmission
path.
A line-of-sight transmission path between the central transceiver and its
associated remote site(s) is highly desirable and provides the most reli-
able communications link.
Much depends on the minimum signal strength that can be tolerated in
a given system. Although the exact figure will differ from one system to
another, a Received Signal Strength Indication (RSSI) of –77 dBm (–80
dBm for iNET II) or stronger will provide acceptable performance in
many systems. While the equipment will work at lower-strength signals,
signals stronger than – 77 dBm provide a “fade margin” of 15 dB to
2.75˝ (7 cm)
7.25˝ (18.4 cm)
132 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
account for variations in signal strength that may occur from
time-to-time. RSSI can be measured with a terminal connected to the
COM1 Port or with a HTTP browser to the LAN (Ethernet) connector.
(See “Antenna Aiming” on Page 125 for details.)
5.1.4 Antenna & Feedline Selection
NOTE: The transceiver is a Professional Installation radio system and
must be installed by trained professional installers, or factory
trained technicians.
This text that follows is designed to aid the professional
installer in the proper methods of maintaining compliance with
FCC Part 15 limits and the +36 dBm or 4 watts peak E.I.R.P
limit.
Antennas
The equipment can be used with a number of antennas. The exact style
used depends on the physical size and layout of a system. Contact your
factory representative for specific recommendations on antenna types
and hardware sources.
In general, an omnidirectional antenna (Figure 5-4) is used at the Access
Point station site. This provides equal coverage to all of the Remote
Gateway sites.
NOTE: Antenna polarization is important. If the wrong polarization is
used, a signal reduction of 20 dB or more will result. Most
systems using a gain-type omnidirectional antenna at the
Access Point station employ vertical polarization of the signal;
therefore, the remote antenna(s) must also be vertically polar-
ized (elements oriented perpendicular to the horizon).
When required, horizontally polarized omnidirectional
antennas are also available. Contact your factory representa-
tive for details.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 133
Invisible place holder
Figure 5-4. Typical Omnidirectional Antennas
At Remote Gateway sites and units in point-to-point LANs, a directional
Yagi (Figure 5-5) antenna is generally recommended to minimize inter-
ference to and from other users. Antennas are available from a number
of manufacturers.
Invisible place holder
Figure 5-5. Typical Yagi Antenna (mounted to mast)
Feedlines
The choice of feedline used with the antenna should be carefully consid-
ered. Poor-quality coaxial cables should be avoided, as they will
degrade system performance for both transmission and reception. The
cable should be kept as short as possible to minimize signal loss.
For cable runs of less than 20 feet (6 meters), or for short range trans-
mission, an inexpensive type such as Type RG-8A/U may be acceptable.
Otherwise, we recommend using a low-loss cable type suited for
900 MHz, such as Heliax®.
Table 5-1 lists several types of popular feedlines and indicates the signal
losses (in dB) that result when using various lengths of cable at
High-gain Type
Unity-gain Type
134 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
900 MHz. The choice of cable will depend on the required length, cost
considerations, and the amount of signal loss that can be tolerated.
The tables below outline the minimum lengths of RG-214 coaxial cable
that must be used with common MDS omnidirectional antennas in order
to maintain compliance with FCC maximum limit of +36 dBi. If other
coaxial cable is used, the appropriate changes in loss figures must be
made.
NOTE: The authority to operate the transceiver in the USA may be
void if antennas other than those approved by the FCC are
used. Contact your MDS representative for additional antenna
information.
*Refer to Table 5-3 for allowable power settings of the transceiver for
each antenna type.
Table 5-1. Length vs. Loss in Coaxial Cables at 900 MHz
Cable Type 10 Feet
(3.05 m) 50 Feet
(15.24 m) 100 Feet
(30.48 m) 500 Feet
(152.4 m)
RG-214 .76 dB 3.8 dB 7.6 dB Unacceptable
Loss
LMR-400 0.39 dB 1.95 dB 3.90 dB Unacceptable
Loss
1/2 inch HELIAX 0.23 dB 1.15 dB 2.29 dB 11.45 dB
7/8 inch HELIAX 0.13 dB 0.64 dB 1.28 dB 6.40 dB
1-1/4 inch HELIAX 0.10 dB 0.48 dB 0.95 dB 4.75 dB
1-5/8 inch HELIAX 0.08 dB 0.40 dB 0.80 dB 4.00 dB
Table 5-2. Feedline Length vs. Antenna Gain*
(Required for Regulatory compliance)
Antenna
Gain (dBd) Antenna
Gain (dBi) Minimum Feedline
Length (Loss in dB) EIRP Level @
Min. Length Maxrad Antenna
Part No.
Unity (0 dB) 2.15 dBi No minimum length +32.15 dBm Omni #MFB900
3 dBd 5.15 dBi No minimum length +35.15 dBm Omni # MFB900
5 dBd 7.15 dBi 3.1 meters (1.2 dB) +35.95 dBm Omni # MFB900
6 dBd 8.15 dBi 9.1 meters (2.2 dB) +35.95 dBm Yagi # BMOY8903
10 dBd 12.15 dBi 24.7 meters (6.15 dB) +35.25 dBm Yagi # Z941
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 135
NOTE: There is no minimum feedline length required when a 6 dBi
gain or less antenna is used, as the EIRP will never exceed 36
dBm which is the maximum allowed, per FCC rules. The
transceiver’s RF output power may only be adjusted by the
manufacturer or its sub-contracted Professional Installer.
The MDS iNET II Transceiver is factory set to +29 dBm
power output to maintain compliance with the FCC’s Digital
Transmission System (DTS) Part 15 rules. These rules limit
power to a maximum of 8 dBm/3 kHz, thus the iNET II Trans-
ceiver is factory set to +29 dBm. When calculating maximum
transceiver power output for iNET II installations, use +29
dBm if antenna gain is 6 dBi or less. See How Much Output
Power Can be Used? on Page 135 for power control of higher
gain antennas.
5.1.5 How Much Output Power Can be Used?
The transceiver is normally supplied from the factory set for a nominal
+30 dBm (+29 dBm for iNET II) RF power output setting; this is the
maximum transmitter output power allowed under FCC rules. The
power must be decreased from this level if the antenna system gain
exceeds 6 dBi. The allowable level is dependent on the antenna gain,
feedline loss, and the transmitter output power setting.
NOTE: In some countries, the maximum allowable RF output may be
limited to less than the figures referenced here. Be sure to
check for and comply with the requirements for your area.
5.1.6 Conducting a Site Survey
If you are in doubt about the suitability of the radio sites in your system,
it is best to evaluate them before a permanent installation is underway.
This can be done with an on-the-air test (preferred method); or indi-
rectly, using path-study software.
An on-the-air test is preferred because it allows you to see firsthand the
factors involved at an installation site and to directly observe the quality
of system operation. Even if a computer path study was conducted ear-
lier, this test should be done to verify the predicted results.
The test can be performed by first installing a radio and antenna at the
proposed Access Point (AP) station site (one-per-system). Then visit the
Remote site(s) with another transceiver (programmed as a remote) and
a hand-held antenna. (A PC with a network adapter can be connected to
each radio in the network to simulate data during this test using the
PING command.)
With the hand-held antenna positioned near the proposed mounting
spot, a technician can check for synchronization with the Access Point
136 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
station (shown by a lit LINK LED on the front panel) and measure the
reported RSSI value. (See “Antenna Aiming” on Page 125 for details.)
If adequate signal strength cannot be obtained, it may be necessary to
mount the station antennas higher, use higher gain antennas, select a dif-
ferent site or consider installing a repeater station. To prepare the equip-
ment for an on-the-air test, follow the general installation procedures
given in this guide and become familiar with the operating instructions
found in the CHAPTER-3 EMBEDDED MANAGEMENT SYSTEM sec-
tion Page 25.
5.1.7 A Word About Radio Interference
The transceiver shares the radio-frequency spectrum with other 900
MHz services and other Part 15 (unlicensed) devices in the USA. As
such, near 100% error-free communications may not be achieved in a
given location, and some level of interference should be expected. How-
ever, the radio’s flexible design and hopping techniques should allow
adequate performance as long as care is taken in choosing station loca-
tion, configuration of radio parameters and software/protocol tech-
niques.
In general, keep the following points in mind when setting up your com-
munications network.
• Systems installed in rural areas are least likely to encounter interfer-
ence; those in suburban and urban environments are more likely to
be affected by other devices operating in the license-free frequency
band and by adjacent licensed services.
• Use a directional antenna at remote sites whenever possible.
Although these antennas may be more costly than omnidirectional
types, they confine the transmission and reception pattern to a com-
paratively narrow lobe, that minimizes interference to (and from)
stations located outside the pattern.
•If interference is suspected from a nearby licensed system (such as a
paging transmitter), it may be helpful to use horizontal polarization
of all antennas in the network. Because most other services use ver-
tical polarization in this band, an additional 20 dB of attenuation to
interference can be achieved by using horizontal polarization.
Another approach is to use a bandpass filter to attenuate all signals
outside the 900 MHz band.
• Multiple Access Point units can co-exist in proximity to each other
with only very minor interference. Each network name has a differ-
ent hop pattern. (See “Protected Network Operation using Multiple
Access Points” on Page 12.) Additional isolation can be achieved by
using separate directional antennas with as much vertical or horizon-
tal separation as is practical.
• If constant interference is present in a particular frequency zone
(collection of 8 RF channels), it may be necessary to “skip” that
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 137
zone from the radio’s hopping pattern. The radio includes built-in
software to help users identify and remove blocked frequency zones
from its hopping pattern. See Page 56 for more information on Skip
Zones.
• If interference problems persist even after skipping some zones, try
reducing the length of data streams. Groups of short data streams
have a better chance of getting through in the presence of interfer-
ence than do long streams.
• The power output of all radios in a system should be set for the low-
est level necessary for reliable communications. This lessens the
chance of causing unnecessary interference to nearby systems.
If you are not familiar with these interference-control techniques, con-
tact your factory representative for more information.
Calculating System Gain
To determine the maximum allowable power setting of the radio, per-
form the following steps:
1. Determine the antenna system gain by subtracting the feedline loss
(in dB) from the antenna gain (in dBi). For example, if the antenna
gain is 9.5 dBi, and the feedline loss is 1.5 dB, the antenna system
gain would be 8 dB. (If the antenna system gain is 6 dB or less, no
power adjustment is required.)
2. Subtract the antenna system gain from 36 dBm (the maximum
allowable EIRP). The result indicates the maximum transmitter
power (in dBm) allowed under the rules. In the example above, this
is 28 dBm.
3. If the maximum transmitter power allowed is less than 30 dBm, set
the power to the desired level using the Management System.
(Main Menu>>Radio Configuration>>RF Output Power Setpoint)
For convenience, Table 5-3 lists several antenna system gains and
shows the maximum allowable power setting of the radio. Note that a
gain of 6 dB or less entitles you to operate the radio at full power output
–30 dBm (28.7 dBm for iNET II).
138 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
* Most antenna manufacturers rate antenna gain in dBd in their litera-
ture. To convert to dBi, add 2.15 dB.
† Feedline loss varies by cable type and length. To determine the loss
for common lengths of feedline, see Ta ble 5-1 on Page 134.
For assistance in the conversion of dBm to Watts, please see
dBm-WATTS-VOLTS CONVERSION CHART on Page 139.
Table 5-3. Antenna System Gain vs. Power Output Setting
Antenna System Gain
(Antenna Gain in dBi*
minus Feedline Loss in dB†)
Maximum Power Setting
(PWR command)
iNET Radio
Maximum Power Setting
(PWR command)
iNET II Radio EIRP
(in dBm)
Omni 6 (or less) 30 28 36
Omni 9 27 26 36
Yagi 12 24 23 36
Yagi 14 22 Not allowable 36
Yagi 16 20 Not allowable 36
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 139
5.2 dBm-WATTS-VOLTS CONVERSION
CHART
Table 5-4 is provided as a convenience for determining the equivalent
voltage or wattage of an RF power expressed in dBm.
Table 5-4. dBm-Watts-Volts conversion—for 50 ohm systems
dBm V Po
+53 100.0 200W
+50 70.7 100W
+49 64.0 80W
+48 58.0 64W
+47 50.0 50W
+46 44.5 40W
+45 40.0 32W
+44 32.5 25W
+43 32.0 20W
+42 28.0 16W
+41 26.2 12.5W
+40 22.5 10W
+39 20.0 8W
+38 18.0 6.4W
+37 16.0 5W
+36 14.1 4W
+35 12.5 3.2W
+34 11.5 2.5W
+33 10.0 2W
+32 9.0 1.6W
+31 8.0 1.25W
+30 7.10 1.0W
+29 6.40 800mW
+28 5.80 640mW
+27 5.00 500mW
+26 4.45 400mW
+25 4.00 320mW
+24 3.55 250mW
+23 3.20 200mW
+22 2.80 160mW
+21 2.52 125mW
+20 2.25 100mW
+19 2.00 80mW
+18 1.80 64mW
+17 1.60 50mW
+16 1.41 40mW
+15 1.25 32mW
+14 1.15 25mW
+13 1.00 20mW
+12 .90 16mW
+11 .80 12.5mW
+10 .71 10mW
+9 .64 8mW
+8 .58 6.4mW
+7 .500 5mW
+6 .445 4mW
+5 .400 3.2mW
+4 .355 2.5mW
+3 .320 2.0mW
+2 .280 1.6mW
+1 .252 1.25mW
dBm V Po
0 .225 1.0mW
-1 .200 .80mW
-2 .180 .64mW
-3 .160 .50mW
-4 .141 .40mW
-5 .125 .32mW
-6 .115 .25mW
-7 .100 .20mW
-8 .090 .16mW
-9 .080 .125mW
-10 .071 .10mW
-11 .064
-12 .058
-13 .050
-14 .045
-15 .040
-16 .0355
dBm mV Po
-17 31.5
-18 28.5
-19 25.1
-20 22.5 .01mW
-21 20.0
-22 17.9
-23 15.9
-24 14.1
-25 12.8
-26 11.5
-27 10.0
-28 8.9
-29 8.0
-30 7.1 .001mW
-31 6.25
-32 5.8
-33 5.0
-34 4.5
-35 4.0
-36 3.5
-37 3.2
-38 2.85
-39 2.5
-40 2.25 .1µW
-41 2.0
-42 1.8
-43 1.6
-44 1.4
-45 1.25
-46 1.18
-47 1.00
-48 0.90
dBm mV Po
-49 0.80
-50 0.71 .01µW
-51 0.64
-52 0.57
-53 0.50
-54 0.45
-55 0.40
-56 0.351
-57 0.32
-58 0.286
-59 0.251
-60 0.225 .001µW
-61 0.200
-62 0.180
-63 0.160
-64 0.141
dBm µV Po
-65 128
-66 115
-67 100
-68 90
-69 80
-70 71 .1nW
-71 65
-72 58
-73 50
-74 45
-75 40
-76 35
-77 32
-78 29
-79 25
-80 22.5 .01nW
-81 20.0
-82 18.0
-83 16.0
-84 11.1
-85 12.9
-86 11.5
-87 10.0
-88 9.0
-89 8.0
-90 7.1 .001nW
-91 6.1
-92 5.75
-93 5.0
-94 4.5
-95 4.0
-96 3.51
-97 3.2
dBm µV Po
-98 2.9
-99 2.51
-100 2.25 .1pW
-101 2.0
-102 1.8
-103 1.6
-104 1.41
-105 1.27
-106 1.18
dBm nV Po
-107 1000
-108 900
-109 800
-110 710 .01pW
-111 640
-112 580
-113 500
-114 450
-115 400
-116 355
-117 325
-118 285
-119 251
-120 225 .001pW
-121 200
-122 180
-123 160
-124 141
-125 128
-126 117
-127 100
-128 90
-129 80 .1ƒW
-130 71
-131 61
-132 58
-133 50
-134 45
-135 40
-136 35
-137 33
-138 29
-139 25
-140 23 .01ƒW
140 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 141
6TECHNICAL REFERENCE
6 Chapter Counter Reset Paragraph
Contents
6.1 DATA INTERFACE CONNECTORS......................................... 143
6.1.1 LAN Port ...................................................................................143
6.1.2 COM1 Port ............................................................................... 144
6.1.3 COM2 Port ............................................................................... 144
6.2 FUSE REPLACEMENT PROCEDURE ...................................145
6.3 TECHNICAL SPECIFICATIONS .............................................. 146
6.4 CHANNEL HOP TABLE........................................................... 149
6.5 SNMP USAGE NOTES............................................................151
6.5.1 Overview ..................................................................................151
142 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 143
6.1 DATA INTERFACE CONNECTORS
Three data interface connectors are provided on the face of the trans-
ceiver. The first, the LAN Port, is an RJ-45 connector. The other two use
two DB-9 interface connectors that use the RS-232 (EIA-232) signaling
standard. Note that the connector for COM1 Port is DCE (Female DB-9)
and the COM2 Port is DTE (male DB-9).
The transceiver meets U.S.A.’s FCC Part 15, Class A limits when used
with shielded data cables.
6.1.1 LAN Port
The transceiver’s LAN Port is used to connect the radio to an Ethernet
network. The transceiver provides a data link to an Internet Pro-
tocol-based (IP) network via the Access Point station. Each radio in the
network must have a unique IP address for the network to function prop-
erly.
• To connect a PC directly to the radio’s LAN port, an RJ-45 to
RJ-45 cross-over cable is required.
• To connect the radio to a Ethernet hub or bridge, use a
straight-through cable.
The connector uses the standard Ethernet RJ-45 cables and wiring. For
custom-made cables, use the pinout information below.
Figure 6-1. LAN Port (RJ-45) Pinout
(Viewed from the outside of the unit)
Table 6-1. LAN Port (IP/Ethernet)
Pin Functions Ref.
1 Transmit Data (TX) High
2 Transmit Data (TX) Low
3 Receive Data (RX) High
4 Unused
5 Unused
6 Receive Data (RX) Low
7 Unused
8 Unused
CAUTION
RADIO FREQUENCY
INTERFERENCE
POTENTIAL
1 2 3 4 5 6 7 8
144 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
6.1.2 COM1 Port
To connect a PC to the transceiver’s COM1 port use a DB-9M to DB-9F
“straight-through” cable. These cables are available commercially, or
may be constructed using the pinout information in Figure 6-2 and
Table 6-2.
Figure 6-2. COM1 Port (DCE)
(Viewed from the outside of the unit.)
6.1.3 COM2 Port
To connect a PC to the transceiver’s COM2 port use a DB-9F to DB-9M
“straight-through” cable. These cables are available commercially, or
may be constructed using the pinout information in Figure 6-2 and
Table 6-2.
Figure 6-3. COM2 Port (DTE)
Viewed from the outside of the radio
Table 6-2. COM1 Port Pinout, DB-9F/RS-232 Interface
Pin Functions DCE
1 Unused
2 Receive Data (RXD) <—[ Out
3 Transmit Data (TXD) —>[ In
4 Unused
5 Signal Ground (GND)
6–9 Unused
Table 6-3. COM2 Port, DB-9M/EIA-232 Interface
Pin Functions DTE
1 Data Carrier Detect (DCD) In ]<—
2 Receive Data (RXD) In ]<—
3 Transmit Data (TXD) Out ]—>
4 Data Terminal Ready (DTR) Out ]—>
5 Signal Ground (GND)
1
5
96
5
1
69
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 145
6.2 FUSE REPLACEMENT
PROCEDURE
An internal fuse protects the transceiver from over-current conditions or
an internal component failure. It should not be replaced until you are
certain you are in a safe (non-flammable) environment.
1. Disconnect the primary power source and all other connections to
the unit.
2. Place the radio on its back and remove the four Phillips screws on
the bottom cover.
3. Carefully separate the top and bottom covers. There is a flat ribbon
cable between the top cover’s LEDs and the unit motherboard. You
do not need to disconnect the ribbon cable.
4. Locate the fuse and fuse holder between the COM1 port and the
power connector. See Figure 6-4 for details.
5. Loosen the fuse from the holder using a very small screwdriver. Use
a small pair of needle-nose pliers to pull the fuse straight up and
remove it.
6. Using an Ohmmeter, or other continuity tester, verify the fuse is
blown.
7. Install a new fuse by reversing the process.
Littelfuse P/N: 0454002; 452 Series, 2 Amp SMF Slo-Blo
MDS P/N: 29-1784A03
6 Data Set Ready (DSR) In ]<—
7 Request-to-Send (RTS) Out ]—>
8 Clear-to-Send (CTS) In ]<—
9 Unused
Table 6-3. COM2 Port, DB-9M/EIA-232 Interface
Pin Functions DTE
146 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
8. Install the covers and check the transceiver for proper operation.
Invisible place holder
6.3 TECHNICAL SPECIFICATIONS
GENERAL
Temperature Range: –30° C to +60° C (–22° F to 140° F)
Humidity: 95% at +40° C (104° F); non-condensing
Primary Power: 10–30 Vdc (13.8 Vdc Nominal)
External Power Supply Options: 110–120/210–220 Vac
Supply Current (typical): (9 Watts Maximum @ 1 Watt RF Output)
Transmit: 8 watts (10.5-24 Vdc)
9 watts (24.5-30 Vdc)
Receive: 2.8 watts (10.5-24 Vdc)
3.5 watts (24.5-30 Vdc)
MTBF: 35 Years (Telcordia Method 1, Case 3)
Size (Excluding mtg. hardware): 1.4" x 6.75" x 4.5" (H x W x D)
3.56 x 17.15 x 11.43 cm
Mounting w/Optional Hardware: • Flat surface mounting brackets
• 19” rack (1U high)
Weight: 908 g / 2 lb
Case: Cast Aluminum
Boot Time: ≈ 30 sec
Time Required to Associate
with Access Point: ≈ 20 sec
APPROVALS/HOMOLOGATION
• FCC Part 15.247
E5MDS-NH900
• Industry Canada RSS-210 and RSS-139
CAN 3738A 12098
• UL/CSA Class 1, Div. 2; Groups A, B, C and D
hazardous locations
• Contact factory for information on availability and
governmental approvals in other countries
Figure 6-4.
Internal Fuse and Holder
Assembly Location
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 147
MANAGEMENT TOOLS
• HTTP (Embedded Web server)
• Text-based menu on COM1 serial port
• Telnet
• SNMP v1/v2/v3
• MDS NETview MS™
DATA CHARACTERISTICS
PORTS:
Ethernet:
Interface Connectors: RJ-45 Standard
Data Rate: 10BaseT
Serial (2 Ports):
Signaling Standard: EIA-232/V.24
Interface Connectors: DB-9
Interface: COM1: DCE / COM2: DTE
Data Rate: 1200–115,200 bps
asynchronous
Data Latency: < 10 ms typical
Byte Formats: 7 or 8-bit; even, odd, or no-parity; 1 or 2 stop bits
OPERATING MODES: • Configurable as Access Point or Station LAN
Adapter
•CSMA/CA Wireless Protocol with Collision Avoid-
ance (802.11)
PROTOCOLS: • IEEE 802.11 CSMA/CD (Wireless)
• IEEE 802.3 (Ethernet)
• IP/Ethernet (ICMP, UDP, TCP, ARP)
• Clear-channel mode for serial async multidrop
protocols including: Modbus, DNP.3, Bisync,
BSAP, DF1, TotalFlow, Poll Select
SECURITY
•Approved AP/Remotes list
•Failed login lockdown
•900 MHz FHSS for iNET (DTS for iNET II)—
provides inherent security from 802.11b devices
•Proprietary data framing
•128-bit encryption
•Automatic rotating key algorithm
RADIO CHARACTERISTICS
GENERAL:
Frequency Range: 902–928 MHz ISM Band
148 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Frequency Hopping Range: Ten user-configurable 2.5 MHz-wide zones,
each containing 8 frequencies
Hop Patterns: 8192, based on network name
Frequency Stability: 20 ppm
TRANSMITTER:
Power Output
(at antenna connector): MDS iNET: 0.1 to 1.0 watt (+20 dBm to +30 dBm)
±1.0 dB, set by user
MDS iNET II: 0.1 to 741 mW (+20 to +29 dBm ±1.0
dB, set by user
Duty Cycle: Continuous
Modulation Type: Binary CPFSK
Output Impedance: 50 Ohms
Spurious: –67 dBc
Occupied Bandwidth: MDS iNET: 316.5 kHz
MDS iNET II: 600 kHz
RECEIVER:
Type: Double conversion superheterodyne
Sensitivity: MDS iNET: –92 dBm @ 512 kbps < 1x10-6 BER
MDS iNET: –99 dBm @ 256 kbps < 1x10-6 BER
MDS iNET II: –95 dBm @ 1024 kbps < 1x10-6 BER
MDS iNET II: –96 dBm @ 512 kbps < 1x10-6 BER
Intermodulation: 59 dB Minimum (EIA)
Desensitization: 70 dB
Spurious: 60 dB
RADIO CHARACTERISTICS
GENERAL:
Frequency Range: 902–928 MHz ISM Band
Frequency Hopping Range: Ten user-configurable 2.5 MHz-wide zones,
each containing 8 frequencies
Hop Pattern: Based on network name
Frequency Stability: 20 ppm
TRANSMIT/RECEIVE RANGE
MDS iNET–256 kbps MDS iNET II–512 kbps
Fixed Range (typical): 10–15 miles 10-15 miles
Fixed Range (maximum): 15–25 miles 15-25 miles
Mobile Range (parked): 5–10 miles
Mobile Range (moving): 2–3 miles
MDS iNET–512 kbps MDS iNET II–1024 kbps
Fixed Range (typical): 5–10 miles 5-10 miles
Fixed Range (maximum): 10–15 miles 10-15 miles
Note: Specifications subject to change without notice or obligation.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 149
NOTE: Range calculations for fixed locations assume a 6 dBd gain
Omnidirectional antenna on a 100 ft tower at the AP, a 10 dBd
gain Yagi on a 25 ft mast at the remote with output power
decreased to yield maximum allowable EIRP (36 dBm), a 10
dB fade margin, and a mix of agricultural and commercial
terrain with line of sight.
Range calculations for mobile units assume a 6 dBd gain Omni
on a 100 ft tower at the AP, a 5 dBd gain Omni with 1 watt
output power at 6 ft height, a 10 dB fade margin, and 90%
confidence with near line-of-sight in a mix of agricultural and
commercial terrain.
Actual performance is dependent on many factors including
antenna height, blocked paths, and terrain.
6.4 CHANNEL HOP TABLE
The MDS iNET transceiver’s hop table consists of 80 channels, num-
bered 0 to 79 as listed in Table 6-4. Center frequencies are calculated as
follows (where Fn is the center frequency of channel n):
Fn = 902.5 MHz + n*316.5 kHz
The MDS iNET II transceiver operates on the same channel assign-
ments, but because the modulation bandwidth is 600 kHz instead of
316.5 kHz it is recommended that the installer restrict channel usage to
every other channel for units operating in the same area.
NOTE: Channels 24, 26, and 55 are not used.
Table 6-4. Channel Hop Table
Zone Channel Frequency
10 902.5000
(iNET FHSS lowest channel)
11 902.8165
(iNET II DTS lowest channel)
12 903.1330
13 903.4495
14 903.7660
15 904.0825
16 904.3990
17 904.7155
28 905.0320
29 905.3485
210 905.6650
211 905.9815
212 906.2980
150 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
213 906.6145
214 906.9310
215 907.2475
316 907.5640
317 907.8805
318 908.1970
319 908.5135
320 908.8300
321 909.1465
322 909.4630
323 909.7795
424 910.0960
425 910.4125
426 910.7290
427 911.0455
428 911.3620
429 911.6785
430 911.9950
431 912.3115
532 912.6280
533 912.9445
534 913.2610
535 913.5775
536 913.8940
537 914.2105
538 914.5270
539 914.8435
640 915.1600
641 915.4765
642 915.7930
643 916.1095
644 916.4260
645 916.7425
646 917.0590
647 917.3755
748 917.6920
749 918.0085
750 918.3250
751 918.6415
752 918.9580
753 919.2745
754 919.5910
Table 6-4. Channel Hop Table (Continued)
Zone Channel Frequency
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 151
6.5 SNMP USAGE NOTES
6.5.1 Overview
The firmware release described in this manual contains major changes
to the transceiver’s SNMP Agent, several new MIB variables, and new
Agent configuration options. This guide reviews the changes and shows
how to properly configure the Agent to take advantage of these new fea-
tures.
SNMPv3 Support
The updated SNMP Agent now supports SNMP version 3 (SNMPv3).
The SNMPv3 protocol introduces Authentication (MD5/SHA-1),
Encryption (DES), the USM User Table, and View-Based Access
755 919.9075
856 920.2240
857 920.5405
858 920.8570
859 921.1735
860 921.4900
861 921.8065
862 922.1230
863 922.4395
964 922.7560
965 923.0725
966 923.3890
967 923.7055
968 924.0220
969 924.3385
970 924.6550
971 924.9715
10 72 925.2880
10 73 925.6045
10 74 925.9210
10 75 926.2375
10 76 926.5540
10 77 926.8705
10 78 927.1870
(iNET FHSS highest channel)
10 79 927.5035
(iNET II DTS highest channel)
Table 6-4. Channel Hop Table (Continued)
Zone Channel Frequency
152 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
(Refer to RFC2574 for full details). The SNMP Agent has limited
SNMPv3 support in the following areas:
• Only MD5 Authentication is supported (no SHA-1). SNMPv3
provides support for MD5 and SHA-1. Currently, only MD5
Authentication is supported in the SNMP Agent.
• Limited USM User Table Manipulation. The SNMP Agent
starts with 5 default accounts. New accounts can be added
(SNMPv3 adds new accounts by cloning existing ones), but
they will be volatile (will not survive a power-cycle).
New views cannot be configured on the SNMP Agent. Views
will be inherited for new accounts from the account that was
cloned.
The SNMP Agent uses one password pair (Authentication / Pri-
vacy) for all accounts. This means that when the passwords
change for one user, they change for all users.
SNMPv3 Accounts
The following default accounts are available for the SNMP Agent:
enc_mdsadmin—Read/write account using Authentication and Encryp-
tion
auth_mdsadmin—Read/write account using Authentication
enc_mdsviewer—Read only account using Authentication and Encryp-
tion
auth_mdsviewer—Read only account using Authentication
def_mdsviewer—Read only account with no Authentication or Encryp-
tion
Context Names
The following Context Names are used (please refer to RFC2574 for full
details):
Admin accounts: context_a / Viewer accounts: context_v
All accounts share the same default passwords:
Authentication default password: MDSAuthPwd / Privacy default pass-
word: MDSPrivPwd
Passwords can be changed either locally (via the console) or from an
SNMP Manager, depending on how the Agent is configured. If pass-
words are configured and managed locally, they are non-volatile and
will survive a power-cycle. If passwords are configured from an SNMP
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 153
manager, they will be reset to whatever has been stored for local man-
agement on power-cycle.
This behavior was chosen based on RFC specifications. The SNMP
Manager and Agent don’t exchange passwords, but actually exchange
keys based on passwords. If the Manager changes the Agent’s password
the Agent doesn’t know the new password; just the new key. In this case,
only the Manager knows the new password. This could cause problems
if the Manager loses the password. If that happens, the Agent becomes
unmanageable. Resetting the Agent’s passwords (and therefore keys) to
what is stored in flash memory upon power-cycle prevents the serious
problem of losing the Agent’s passwords.
If passwords are managed locally, they can be changed on the Agent (via
the console). Any attempts to change the passwords for the Agent via an
SNMP Manager will fail when the Agent is in this mode. Locally
defined passwords will survive a power-cycle.
In either case, the SNMP Manager needs to know the initial passwords
that are being used in order to talk to the Agent. If the Agent’s passwords
are configured via the Manager, then they can be changed from the Man-
ager. If the passwords are managed locally, then the Manager must be
re-configured with any password changes in order to continue to talk to
the Agent.
Password-Mode Management Changes
When the password management mode is changed, the active passwords
used by the Agent may also change. Some common scenarios are dis-
cussed below:
Common Scenarios • Passwords are currently being handled by the Manager. The
assigned passwords are Microwave (Auth), and Rochester (Priv).
Configuration is changed to manage the passwords locally. The
passwords stored on the radio were Fairport (Auth), and
Churchville (Priv) (If local passwords have never been used,
then MDSAuthPwd and MDSPrivPwd will be used). These
passwords will now be used by the Agent to re-generate keys.
The Manager will need to know these passwords in order to talk
to the Agent.
•Passwords are currently being managed locally. The local pass-
words are Fairport (Auth) and Churchville (Priv). Configuration is
changed to handle the passwords from the Manager. The same
passwords will continue to be used, but now the Manager can
change them.
•Passwords are currently being managed locally. The local pass-
words are Fairport (Auth) and Churchville (Priv). Passwords are
changed to Brighton (Auth) and Perinton (Priv). The Agent will
immediately generate new keys based on these passwords and
start using them. The Manager will have to be re-configured to
use these new passwords.
154 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
•Passwords are currently being managed locally. The local pass-
words are Fairport (Auth) and Churchville (Priv). Configuration is
changed to handle the passwords from the Manager. The Man-
ager changes the passwords to Brighton (Auth) and Perinton
(Priv). The radio is then rebooted. After a power-cycle, the radio
will use the passwords stored in flash, which are Fairport (Auth)
and Churchville (Priv). The Manager will have to be re-config-
ured to use these new passwords.
Table 6-5. SNMP Traps (Sorted by Code)
SNMP Trap Severity Description
systemBoot(32) INFORM SNR Within threshold/Below threshold
systemReboot(33) MAJOR Telnet User Logged Out/Logged In
startScan(34) INFORM Reprogramming Started
rxBeaconErrored(35) INFORM Received Beacon - Netname Does Not Match
rxBeaconWrongNetworkName (36) INFORM Received Beacon - AP is Blacklisted
rxBeaconFromBlacklistAP(37) MAJOR Max Beacon Wait Time Exceeded
expectedSync(38) INFORM Expected Sync Lost/Established
hopSync(39) INFORM Hop Sync Lost/Established
snr(41) INFORM Scanning Started
ber(42) INFORM Bit Error Rate Below threshold/Above threshold
associated(43) MAJOR Association Lost/Established
apParmChange(44) MINOR Association Lost - AP Hop Parameter Changed
reprogStarted(45) MAJOR Reprogramming Failed
reprogComplete(46) MAJOR Rem Ethernet Link Connected/Disconnected
reprogFailed(47) INFORM Reprogramming Complete
telnetLogin(48) MAJOR Telnet Access Locked for 5 Min
httpLogin(49) MAJOR HTTP User Logged Out/Logged In
countrySkipZoneMismatch(50) INFORM Country/SkipZone Mismatch
desiredAPIPMismatch(51) INFORM Desired AP IP Addr Mismatch
eventLogCleared(52) INFORM Log Cleared
authDemoMode(53) MAJOR Auth Demo Mode Expired -- Rebooted
Radio/Enabled
keyEntered(54) MAJOR Auth Key Entered - Key Valid/Key Invalid
apEthLinkDown(55) MAJOR Association Lost - AP's Ethernet Link Down
noBeacons(56) MAJOR MAC Param Changed
apNotApproved(57) MAJOR Current AP No Longer Approved
netnameChanged(58) MAJOR Association Lost - Local Network Name Changed
ipAddrChanged(59) MAJOR Association Lost - Local IP Address Changed
assocTryFail(60) MAJOR Association Attempt Success/Failed
remEthLinkLost(61) INFORM Received Beacon - Valid/Errored
consoleLogin(62) MAJOR Console User Logged Out/Logged In
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 155
consoleLockdown(63) MAJOR Console Access Locked for 5 Min
telnetLockdown(64) INFORM System Bootup (power on)
httpLockdown(65) MAJOR HTTP Access Locked for 5 Min
eventRemote(66) INFORM Remote added/removed from internal database
eventEndpoint(67) INFORM Endpoint added/removed from internal database
routeAdded(68) INFORM Radio attempted but failed to add a route to its
internal routing table
routeDeleted(69) INFORM Radio attempted but failed to delete a route from its
internal routing table
sinRemSwitch(70) INFORM Remote mode was switched (serial to ethernet,
ethernet to serial)
chileChanCnt(71) INFORM Number of channels defined does not match (Chile
only)
tftpConnection(73) INFORM TFTP Server on AP started or finished a transfer
apNetNameChanged(74) MAJOR Remote lost association due to a change in the
AP’s netname
ipConnectivityOK(75) INFORM Radio is associated AND 1) has an IP address
statically defined, OR 2) received an IP address via
DHCP
compressionChanged(76) INFORM Compression state has changed (enabled,
disabled)
macDecryptError(77) INFORM MAC has received a packet that it could not decrypt
lanPortStatus(78) INFORM Ethernet port has changed (enabled, disabled)
tftpConnFailed(79) INFORM TFTP server on AP failed to transfer
sdbError(80) INFORM AP encountered an internal database error
Table 6-5. SNMP Traps (Sorted by Code) (Continued)
SNMP Trap Severity Description
156 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 157
7GLOSSARY OF TERMS
AND ABBREVIATIONS
7 Chapter Counter Reset Paragraph
If you are new to wireless IP/Ethernet systems, some of the terms used
in this guide may be unfamiliar. The following glossary explains many
of these terms and will prove helpful in understanding the operation of
your radio network.
Access Point (AP)—The transceiver in the network that provides syn-
chronization information to one or more associated Remote units. AP
units may be configured for either the Access Point (master) or Remote
services. (See “Network Configuration Menu” on Page 40.)
Active Scanning—See Passive Scanning
Antenna System Gain—A figure, normally expressed in dB, repre-
senting the power increase resulting from the use of a gain-type antenna.
System losses (from the feedline and coaxial connectors, for example)
are subtracted from this figure to calculate the total antenna system gain.
AP—See Access Point
Association—Condition in which the frequency hopping pattern of the
Remote is synchronized with the Access Point station and is ready to
pass traffic.
Authorization Key—Alphanumeric string (code) that is used to enable
additional capabilities in the transceiver.
Bit—The smallest unit of digital data, often represented by a one or a
zero. Eight bits (plus start, stop, and parity bits) usually comprise a byte.
Bits-per-second—See BPS.
BPDU—Bridge Protocol Data Units
BPS—Bits-per-second (bps). A measure of the information transfer rate
of digital data across a communication channel.
Byte—A string of digital data usually made up of eight data bits and
start, stop and parity bits.
CSMA/CA—Carrier Sense Multiple Access/Collision Avoidance
CSMA/CD—Carrier Sense Multiple Access/Collision Detection
Cyclic Redundancy Check (CRC)—A technique used to verify data
integrity. It is based on an algorithm which generates a value derived
158 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
from the number and order of bits in a data string. This value is com-
pared with a locally-generated value and a match indicates that the mes-
sage is unchanged, and therefore valid.
Data Circuit-terminating Equipment—See DCE.
Data Communications Equipment—See DCE.
Datagram—A data string consisting of an IP header and the IP message
within.
Data Terminal Equipment—See DTE.
dBi—Decibels referenced to an “ideal” isotropic radiator in free space.
Frequently used to express antenna gain.
dBm—Decibels referenced to one milliwatt. An absolute unit used to
measure signal power, as in transmitter power output, or received signal
strength.
DCE—Data Circuit-terminating Equipment (or Data Communications
Equipment). In data communications terminology, this is the “modem”
side of a computer-to-modem connection. COM1 Port of the transceiver
is set as DCE.
Decibel (dB)—A measure of the ratio between two signal levels. Fre-
quently used to express the gain (or loss) of a system.
Delimiter—A flag that marks the beginning and end of a data packet.
Device Mode—The operating mode/role of a transceiver (Access Point
or Remote) in a wireless network.
DHCP (Dynamic Host Configuration Protocol)—An Internet stan-
dard that allows a client (i.e. any computer or network device) to obtain
an IP address from a server on the network. This allows network admin-
istrators to avoid the tedious process of manually configuring and man-
aging IP addresses for a large number of users and devices. When a
network device powers on, if it is configured to use DHCP, it will con-
tact a DHCP server on the network and request an IP address.
The DHCP server will provide an address from a pool of addresses allo-
cated by the network administrator. The network device may use this
address on a “time lease” basis or indefinitely depending on the policy
set by the network administrator. The DHCP server can restrict alloca-
tion of IP addresses based on security policies. An Access Point may be
configured by the system administrator to act as a DHCP server if one
is not available on the wired network.
Digital Signal Processing—See DSP.
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 159
DSP—Digital Signal Processing. DSP circuitry is responsible for the
most critical real-time tasks; primarily modulation, demodulation, and
servicing of the data port.
DTE—Data Terminal Equipment. A device that provides data in the
form of digital signals at its output. Connects to the DCE device.
Encapsulation—Process in by which, a complete data packet, such as
Modbus frame or any other polled asynchronous protocol frame, is
placed in the data portion of another protocol frame (in this case IP) to
be transported over a network. Typically this action is done at the receiv-
ing end, before being sent as an IP packet to a network. A similar re-
versed process is applied at the other end of the network extracting the
data from the IP envelope, resulting in the original packet in the original
protocol.
Endpoint—IP address of data equipment connected to the ports of the
radio.
Equalization—The process of reducing the effects of amplitude, fre-
quency or phase distortion with compensating networks.
Fade Margin—The greatest tolerable reduction in average received
signal strength that will be anticipated under most conditions. Provides
an allowance for reduced signal strength due to multipath, slight antenna
movement or changing atmospheric losses. A fade margin of 15 to 20
dB is usually sufficient in most systems.
Fragmentation—A technique used for breaking a large message down
into smaller parts so it can be accommodated by a less capable media.
Frame—A segment of data that adheres to a specific data protocol and
contains definite start and end points. It provides a method of synchro-
nizing transmissions.
Frequency Hopping—The spread spectrum technique used by the
transceiver, where two or more associated radios change their operating
frequencies several times per second using a set pattern. Since the pat-
tern appears to jump around, it is said to “hop” from one frequency to
another.
Frequency Zone—The radio uses up to 80 discrete channels in the 902
to 928 MHz spectrum. A group of 8 channels is referred to as a zone; in
total there are 10 zones.
Hardware Flow Control—A transceiver feature used to prevent data
buffer overruns when handling high-speed data from the connected data
communications device. When the buffer approaches overflow, the
radio drops the clear-to-send (CTS) line, that instructs the connected
device to delay further transmission until CTS again returns to the high
state.
160 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
Hop Pattern Seed—A user-selectable value to be added to the hop pat-
tern formula in an unlikely event of nearly identical hop patterns of two
collocated or nearby radio networks to eliminate adjacent-network inter-
ference.
Host Computer—The computer installed at the master station site, that
controls the collection of data from one or more remote sites.
HTTP—Hypertext Transfer Protocol
IAPP (inter-Access Point Protocol)—A protocol by which access
points share information about the stations that are connected to them.
When a station connects to an access point, the access point updates its
database. When a station leaves one access point and roams to another
access point, the new access point tells the old access point, using IAPP,
that the station has left and is now located on the new access point.
ICMP—Internet Control Message Protocol
IGMP (Internet Gateway Management Protocol)—Ethernet level
protocol used by routers and similar devices to manage the distribution
of multicast addresses in a network.
IEEE—Institute of Electrical and Electronic Engineers
Image (File)—Data file that contains the operating system and other
essential resources for the basic operation of the radio’s CPU.
LAN—Local Area Network
Latency—The delay (usually expressed in milliseconds) between when
data is applied at the transmit port at one radio, until it appears at the
receive port at the other radio.
MAS—Multiple Address System. A radio system where a central
master station communicates with several remote stations for the pur-
pose of gathering telemetry data. Figure 1-2 on Page 6 shows an
example of an MAS system.
MAC—Media Access Controller
MCU—Microcontroller Unit. This is the processor responsible for con-
trolling system start-up, synthesizer loading, hop timing, and key-up
control.
MD5—A highly secure data encoding scheme. MD5 is a one-way hash
algorithm that takes any length of data and produces a 128 bit “finger-
print.” This fingerprint is “non-reversible,” it is computationally infea-
sible to determine the file based on the fingerprint. For more details
review “RFC 1321” available on the Internet.
MIB—Management Information Base
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 161
Microcontroller Unit—See MCU.
Mobile IP—An emerging standard by which access points and stations
maintain network connectivity as the stations move between various IP
networks. Through the use of Mobile IP a station can move from its
home IP network to a foreign network while still sending and receiving
data using it's original IP address. Other hosts on the network will not
need to know that the station is no longer in its home network and can
continue to send data to the IP address that was assigned to the station.
Mobile IP also uses DHCP when the station moves into a foreign net-
work.
Mobility—Refers to a station that moves about while maintaining
active connections with the network. Mobility generally implies phys-
ical motion. The movement of the station is not limited to a specific net-
work and IP subnet. In order for a station to be mobile it must establish
and tear down connections with various access points as it moves
through the access points' territory. To do this, the station employs
roaming and Mobile IP.
Mode—See Device Mode.
MTBF—Mean-Time Between Failures
Multiple Address System (MAS)—See Point-Multipoint System.
Network Name—User-selectable alphanumeric string that is used to
identify a group of radio units that form a communications network. The
Access Point and all Remotes within a given system should have the
same network address.
Network-Wide Diagnostics—An advanced method of controlling and
interrogating MDS radios in a radio network.
NTP—Network Time Protocol
Packet—The basic unit of data carried on a link layer. On an IP net-
work, this refers to an entire IP datagram or a fragment thereof.
Passive Scanning—Scanning is a process used by stations to detect
other access points on network to which it may connect if it needs to
roam. Passive scanning is a slower process in which it listens for infor-
mation offered by the access points on a regular basis. Active scanning
is a faster process in which the station sends out probe message to which
the access points respond. Passive scanning can be done while main-
taining the current network connectivity. Active scanning affects the RF
configuration of the radio and therefore, at least temporarily, discon-
nects the station from the access point.
162 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
PING—Packet INternet Groper. Diagnostic message generally used to
test reachability of a network device, either over a wired or wireless net-
work.
Point-Multipoint System—A radio communications network or
system designed with a central control station that exchanges data with
a number of remote locations equipped with terminal equipment.
Poll—A request for data issued from the host computer (or master PLC)
to a remote radio.
Portability—A station is considered connected when it has successfully
authenticated and associated with an access point. A station is consid-
ered authenticated when it has agreed with the access point on the type
of encryption that will be used for data packets traveling between them.
The process of association causes a station to be bound to an access
point and allows it to receive and transmit packets to and from the access
point. In order for a station to be associated it must first authenticate
with the access point. The authentication and association processes
occur automatically without user intervention.
Portability refers to the ability of a station to connect to an access point
from multiple locations without the need to reconfigure the network set-
tings. For example, a remote transceiver that is connected to an access
point may be turned off, moved to new site, turned back on, and,
assuming the right information is entered, can immediately reconnect to
the access point without user intervention.
PLC—Programmable Logic Controller. A dedicated microprocessor
configured for a specific application with discrete inputs and outputs. It
can serve as a host or as an RTU.
Remote—A transceiver in a network that communicates with an asso-
ciated Access Point.
Remote Terminal Unit—See RTU.
RFI—Radio Frequency Interference
Roaming—A station's ability to automatically switch its wireless con-
nection between various access points as the need arises. A station may
roam from one access point to another because the signal strength or
quality of the current access point has degraded below what another
access point can provide. When two access points are co-located for
redundancy, roaming allows the stations to switch between the access
points to provide a robust network. Roaming may also be employed in
conjunction with Portability where the station has been moved beyond
the range of the original access point to which it was connected. As the
station comes in range of a new access point, it will switch its connec-
tion to the stronger signal. Roaming refers to a station's logical, not nec-
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User’s Guide 163
essarily physical, move between access points within a specific network
and IP subnet.
RSSI—Received Signal Strength Indicator
RTU—Remote Terminal Unit. A data collection device installed at a
remote radio site.
SCADA—Supervisory Control And Data Acquisition. An overall term
for the functions commonly provided through an MAS radio system.
Skip Zone(s)—Groups of operating channels (frequencies) deleted
from the radio transmitter and receiver operating range.
SNMP—Simple Network Management Protocol
SNR—Signal-to-Noise Ratio. A measurement of the desired signal to
ambient noise levels.This measurement provides a relative indication of
signal quality. Because this is a relative number, higher signal-to-noise
ratios indicate improved performance.
SNTP—Simple Network Time Protocol
SSL—Secure Socket Layer
STP—Spanning Tree Protocol
Standing-Wave Ratio—See SWR.
SWR—Standing-Wave Ratio. A parameter related to the ratio between
forward transmitter power and the reflected power from the antenna
system. As a general guideline, reflected power should not exceed 10%
of the forward power (≈ 2:1 SWR).
TCP—Transmission Control Protocol
TFTP—Trivial File Transfer Protocol
Trap Manager—Software that collects SNMP traps for display or log-
ging of events.
UDP—User Datagram Protocol
UTP—Unshielded Twisted Pair
WINS—Windows Internet Naming Service. Part of Microsoft Win-
dows NT and 2000 servers that manages the association of workstation
names and locations with Internet Protocol addresses. It works without
the user or an administrator having to be involved in each configuration
change. Similar to DNS.
Zone—See Frequency Zone.
164 MDS iNET 900 Series User’s Guide MDS 05-2806A01, Rev. E.1
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User s Guide I-1
INDEX
Numerics
100BaseT 129
10BaseT 129
802.11b 8
A
Access Point (AP) 157
accessories 15
Active Scanning 161
Actual Data Rate 76
Add Associated Remotes 75
AgeTime 84, 85
alarm conditions 118
correcting 120
Alarmed 116
Antenna
aiming 125
directional 136
Minimum Feedline Length versus Antenna Gain 134
omnidirectional 133
polarization 132
selection 132
SWR check 124
system gain 157
system gain vs. power output setting 138
Yagi 133
AP
Auto Upgrade 84
Reboot when Upgraded 84
application
IP-to-Serial 67
Mixed-Modes 72
Point-to-Multipoint Serial-to-Serial 69
Point-to-Point Serial-to-Serial 68
Serial Port 72
Approved
Access Points/Remotes List 74
Remotes/Access Points List 75
Associated 116
Association 157
Date 84
Process 83
Time 84
attenuation 20
Auth Traps Status 48
Authorization Key 105, 108, 157
Authorized Features 105
Auto Data Rate Menu
RSSI Threshold/Delta 53
SNR Threshold/Delta 53
Auto Key Rotation 74
Auto-Upgrade/Remote-Reboot 106
B
Backhaul
for Serial Radio Networks 6
Network 7
bandpass filter 136
Beacon
Period 50, 90, 91
signal 83
Begin Wizard 60
Bit 157
bits-per-second (bps) 157
BPDU 88, 157
BPS 157
Bridge Protocol Data Units 88, 157
byte 157
Bytes
in on port 87
in on socket 87
out on port 87
out on socket 87
received 81, 82
sent 81, 82
C
cable
Ethernet crossover 20
feedlines 133
serial 20
Clear
Com# statistics 87
Ethernet stats 82
Log 79
Wireless stats 82
Collocating Multiple Radio Networks 13
Commit Changes and Exit Wizard 62, 63, 65, 66, 67
compression 49, 91
Computer
host 160
configuration 21, 61, 63, 64, 66, 67
basic device parameters 38
defaults 21
DHCP server 44
editing files 104
Ethernet Port 43
file 97, 113
I-2 MDS iNET 900 Series User s Guide MDS 05-2806A01, Rev. E.1
IP address 42
network 40
PPP Mode 66
radio parameters 48
scripts 97, 98
security 73
serial interfaces 56
SNMP Agent 46
TCP Mode 64
UDP mode 60
Connection Status 83
connectors 143
Contact 39
cost of deployment 8
Count 108
CRC (Cyclic Redundancy Check) 157
CSMA
CA 157
CD 157
Current
Alarms 79
AP IP Address 84
AP Mac Address 84
Custom Data Buffer Size 62, 63, 65, 66, 67
Cyclic Redundancy Check (CRC) 157
D
data
baud 67
baud rate 61, 63, 64, 66
buffering 59, 65
compression 91
rate 49
Data Terminal Equipment 159
Database
Logging 42
Timeout 42
Datagram 158
DataRate 85
Date 39
Format 39
dB 158
dBi 158
dBm 158
watts-volts conversion 139
DCE 158
decibel (dB) 158
default gateway 42
defaults
reset to factory 108
Delete
All Remotes 75
Remote 75
Delimiter 158
deployment costs 8
Description 39
Device
IP Address 67
Mode 36, 40, 41, 158
Name 36, 39
Status 36, 116
DHCP 42, 43, 158
Netmask 45
Server Configuration 41
Diagnostic Tools 118
Digital Signal Processing (DSP) 159
dimensions 129
DKEY command 124
DNS Address 45
DSP (Digital Signal Processing) 159
DTE 9, 57, 159
Dwell Time 50, 90
Dynamic Host Configuration Protocol 158
Dynamic Mode 43
E
EIA-232 9
Embedded Management System 21
Encapsulation 159
Encryption 74
Phrase 74
Ending Address 45
Endpoint 159
Listing 77
Listing Menu 85
ENI, MDS iNET 900 3
Equalization 159
Ethernet
Address 42
Link (H/W) Watch 44
Link Poll Address 44
Packet Statistics 82
port enabled/disabled 44
Rate Limit 44
Event Log 77, 78, 116, 118, 120, 121
F
Fade Margin 159
Feedline
selection 132, 133
Filename 80, 93, 97
firmware
installing 94
upgrade 93, 106
version 37, 38
Flow Control 59, 61, 63, 64, 66, 67
hardware 159
Force Key Rotation 74
Force Reboot 106
Fragmentation 159
Threshold 50, 88, 90
Frame 159
Frequency 107
hopping 159
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User s Guide I-3
zone 159
fuse replacement 145
G
gain
antenna 157
system 137
Glossary 157—163
Go 108
H
Hardware
flow control 159
Version 37, 38
Hop
Format 51
pattern 136
Pattern Seed 50, 160
Sync 116
Hopping
channels 149
frequency 159
pattern seed 160
Host computer 160
HTTP 160
Access 74
Security Mode 74
Hypertext Transfer Protocol 160
I
IANA 58
IAPP 160
ICMP 160
IEEE 160
IETF standard RFC1213 46
IGMP 160
Image
Copy 93
file 160
Verify 93
iNET II 50
iNET II, differences of 3, 4, 5, 14, 48, 49, 50, 51, 53, 54, 86,
125, 131, 135
Installation
antenna & feedline 132
feedline selection 133
general information 3
planning 129
requirements 129
site selection 131
site survey 135
Institute of Electrical and Electronic Engineers 160
Inter-Access Point Protocol 160
Interference 136
Internet
Assigned Numbers Authority 58
Control Message Protocol 160
IP 44
Addr 108
Address 36, 40, 84, 85, 104
address 43
Address Configuration 41
Address Mode 43
Gateway 104
Mobile 161
Protocol 61, 62, 64, 65, 67
tunneling 57
K
Key
authorization 157
transmitter, for antenna SWR check 124
KEY command 124
L
LAN 43, 160
Latency 90, 160
Latest AP Firmware Version 84
LED
COM1 23
COM2 23
LAN 23, 114
LINK 23, 24, 114, 126, 136
PWR 23, 78, 80, 114, 118, 121
use during troubleshooting 113
Link Established 67
Local
Area Network 160
IP Port 61, 62
Listening IP Port 65
Location 39, 104
Logged Events 121
Lost Carrier Detected 82, 117
M
MAC Address 84, 85, 88
Management Information Base 160
Management System 21
user interfaces 27
MAS 160
Master Station 160
Maximum Remotes 41
MCU (Microcontroller Unit) 160
MD5 160
MDS iNET 900 ENI 3
MDS Security Suite 14
SNMP traps 15
Mean-Time Between Failures 161
measurements
I-4 MDS iNET 900 Series User s Guide MDS 05-2806A01, Rev. E.1
radio 123
MIB 160
files 46
Microcontroller Unit 160
Mobile 54
Mobile Data
Beacon Period 56
Compression 55
configuration 54
Dwell Time 56
Fragmentation Threshold 56
RTS Threshold 56
Mobile IP 161
Mobility 161
Mobility Capability 10
MODBUS 65
Mode
Device 158
mixed 71
serial gateway interface 10
TCP 10
UDP 10
Model Number 38
MTBF 161
Multicast
IP Address 61
IP Port 61
multiple
protocols 7
services 7
Multiple Address System (MAS) 160
N
NEMA 8
net mask 42
NETview MS 105
Network
Name 13, 19, 36, 40, 41, 104, 161
Time Protocol (NTP) 161
-wide diagnostics 161
network
bridge 87
maintenance 91
operation principles 87
performance optimization 90
performance verification 76
network design 10
antennas 11
collocating multiple radio networks 13
network name 11
repeaters 10
using multiple Access Points 12
Using the AP as a Store-and-Forward Packet Repeater 12
using two transceivers to form a repeater station 10
NTP (Network Time Protocol) 161
O
Outgoing Connection s Inactivity Timeout 64
Owner 39
P
Packet 161
Redundancy Mode 61, 63
Size 108
Statistics 77, 81, 117
Packets
Dropped 81, 82, 117
Received 81, 82
Received by Zone 82
Sent 81, 82
Passive Scanning 161
password
resetting 108
PC
connection to transceiver 20
Performance Information Menu 90
PING 19, 24, 135, 162
Ping Utility 108
PLC 8, 162
Point-Multipoint System 162
Point-to-Point
LAN Extension 6
Link 6
Poll 162
port
antenna 124
COM1 9, 20, 21, 22, 57, 68, 132, 144
COM2 9, 22, 57, 68, 144
Ethernet 19
IP 68
LAN 21, 22, 143
not Enabled 67
Portability 162
ports
serial 7
power
how much can be used 135
primary 20
transmitter power output 124
PPP 59
Primary Host Address 64
Primary IP Port 64
Programmable Logic Controller 8
protocol
BPDU 88
HTTP 160
IAPP 160
ICMP 160
IP 22, 44, 56
MODBUS 65
PPP 59
SNMP 27, 46, 151, 163
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User s Guide I-5
SNTP 41, 163
STP 88, 163
TCP 57, 58, 64, 67, 71, 90, 163
TFTP 94, 163
UDP 57, 58, 67, 68, 71, 90, 163
R
Radio
Frequency Interference 13, 136
Remote 162
Test 107
range, transmission 8
Read Community String 47
Reboot
Device 93
on Upgrade 106
Receive errors 81, 82, 117
Received Signal Strength Indicator 20, 131, 163
Redundancy
Using multiple Access Points 12
Remote
IP Address 62
IP Port 62
Listing 77
Listing Menu 84
Performance Listing 77, 86
radio 162
Terminal Unit 8, 163
Repeater 10
antennas 11
Network Name 11
Using the AP as a Store-and-Forward Packet Repeater 12
Using two transceivers to form a repeater station 10
reprogramming 92
Restart DHCP Server 45
Retries 82, 117
Retrieve File 93, 97
Retry errors 82, 117
RetryEr 86
RF Output Power 49, 76
RFI 13, 162
Roaming 162
RSSI 20, 76, 108, 117, 125, 131, 163
by Zone 76, 77
Threshold 51
RTS Threshold 50, 88, 90
RTS/CTS handshaking 61
RTU 8, 57, 68, 72, 163
RxBCMC 86
RxPkts 85, 86
RxRate 86
RxViaEP 86
S
Save Changes 75
SCADA 7, 8, 58, 163
Scanning 116
Active 161
Passive 161
Seamless Inter-Frame Delay 61, 63, 65, 66, 67
Secondary
Host Address 64
IP Port 64
Secure Socket Layer 163
security
Approved Access Points/Remotes List 74
Auto Key Rotation 74
encryption 74
Encryption Phrase 74
Force Key Rotation 74
general information 3
HTTP Access 74
HTTP Security Mode 74
risks 14
SNMP Access 74
suite 14
Telnet Access 74
Two-Way Authentication 73
User Password 74
security suite
SNMP traps 15
Send
File 97
Log 79
Sending LCP Requests 67
Serial
Configuration Wizard 59
Data Statistics 87
encapsulation 57
Mode 61, 63, 65, 66, 67
Number 37, 38
Port Statistics 117
radio networks, backhaul 6
Server Status 45
Signal strength 131
Signal-to-Noise Ratio 76, 163
Simple Network
Management Protocol 163
Time Protocol 163
Site selection 131
Skip Zone 163
SNMP 27, 163
Access 74
Config Menu 41
Mode 47
traps 15, 154
usage 151
V3 Passwords 48
SNR 51, 163
Threshold 51
SNTP 41, 163
Spanning Tree Protocol 88, 163
Specifications 146—149
SSL 163
Standing Wave Ratio 163
MDS 05-2806A01, Rev. E.1 MDS iNET 900 Series User s Guide I-6
Starting
Address 45
Information Screen 37
State 84
Static IP
Address 43
Gateway 43
Netmask 43
Status 36, 60, 62, 64, 65, 67
STP 163
subnet 43
Supervisory Control and Data Acquisition (SCADA) 163
SWR 124, 163
performance optimization 124
Syslog Server 80
system gain, antenna 157
System Mode 104
T
TCP 10, 58, 71, 90, 163
Client 58
Server 58
Telnet 68
Access 74
Test Mode 107
TFTP 163
Host Address 79, 93, 97
Time-out 80
Timeout 93, 97
Time 39
Time to Live (TTL) 61
Transmission
Control Protocol 163
range 8
transparent encapsulation 57
Trap
Community String 47
Manager 48, 163
Version 48
Trivial File Transfer Protocol 163
Troubleshooting 113—123
Using the Embedded Management System 114
Two-Way Authentication 73
TX Output Power 107
TxKey 108
TxPkt 86
TxPkts 86
TxViaEP 86
U
UDP 10, 58, 68, 71, 90, 163
mode 60
Unit Name 104
Unshielded Twisted Pair 163
Uptime 37, 39
User Datagram Protocol 163
User Password 74
Using multiple Access Points 12
UTP 163
V
V3
Authentication Password 47
Privacy Password 47
via Remote 85
View
Approved Remotes 75
Current Alarms 80
Current Settings 60
Event Log 81
Log 79
volts-dBm-watts conversion 139
W
watts-dBm-volts conversion 139
WINS 163
Address 45
Wireless
Address 42
Network Status 77, 83
Packet Statistics 81
wizard
serial configuration 59
Write community String 47
Y
Yagi antenna 133
IN CASE OF DIFFICULTY...
MDS products are designed for long life and trouble-free operation. However, this equipment, as
with all electronic equipment, may have an occasional component failure. The following informa-
tion will assist you in the event that servicing becomes necessary.
TECHNICAL ASSISTANCE
Technical assistance for MDS products is available from our Technical Support Department during
business hours (8:00 A.M.—5:30 P.M. Eastern Time). When calling, please give the complete
model number of the radio, along with a description of the trouble/symptom(s) that you are expe-
riencing. In many cases, problems can be resolved over the telephone, without the need for
returning the unit to the factory. Please use one of the following means for product assistance:
Phone: 585 241-5510 E-Mail: TechSupport@microwavedata.com
FAX: 585 242-8369 Web: www.microwavedata.com
FACTORY SERVICE
Component level repair of radio equipment is not recommended in the field. Many components are
installed using surface mount technology, which requires specialized training and equipment for
proper servicing. For this reason, the equipment should be returned to the factory for any PC board
repairs. The factory is best equipped to diagnose, repair and align your radio to its proper operating
specifications.
If return of the equipment is necessary, you will be issued a Service Request Order (SRO) number.
The SRO number will help expedite the repair so that the equipment can be repaired and returned
to you as quickly as possible. Please be sure to include the SRO number on the outside of the ship-
ping box, and on any correspondence relating to the repair. No equipment will be accepted for
repair without an SRO number.
A statement should accompany the radio describing, in detail, the trouble symptom(s), and a
description of any associated equipment normally connected to the radio. It is also important to
include the name and telephone number of a person in your organization who can be contacted if
additional information is required.
The radio must be properly packed for return to the factory. The original shipping container and
packaging materials should be used whenever possible. All factory returns should be addressed to:
Microwave Data Systems
Product Services Department
(SRO No. XXXX)
175 Science Parkway
Rochester, NY 14620 USA
When repairs have been completed, the equipment will be returned to you by the same shipping
method used to send it to the factory. Please specify if you wish to make different shipping arrange-
ments. To inquire about an in-process repair, you may contact our Product Services Group at 585-
241-5540 (FAX: 585-242-8400), or via e-mail at ProductServices@microwavedata.com.
Microwave Data Systems Inc.
Rochester, NY 14620
General Business: +1 585 242-9600
FAX: +1 585 242-9620
Web: www.microwavedata.com
175 Science Parkway
A product of Microwave Data Systems Inc.