GE MDS DS-LN200 Industrial Radio Module User Manual
GE MDS LLC Industrial Radio Module Users Manual
GE MDS >
Contents
- 1. User Manual
- 2. Users Manual
Users Manual
MDS LN200 Integrator’s Guide 1.0 INTRODUCTION The LN200 (Figure 1), is a fixed location (not intended for mobile use), multi-modem system operating in licensed bands between 216-222MHz, using channel bandwidths of 6.25kHz, 12.5kHz, 25.0kHz and 50kHz. Modulation choices for each bandwidth include CPFSK, QPSK, 16QAM, and 64QAM. Maximum power and modem speed is based on frequency, modem choice, and applicable emission mask. The unit is designed for use inside data equipment to provide reliable connectivity in wireless networks. The LN200 power control circuit ensures that the RF output is linear and never exceeds +41.3 dBm at the antenna connector. The module is designed for OEM use only. Host systems must be professionally installed. Host systems must be factory configured by the OEM to operate at the correct frequency and output power setting. Refer to the table at the end of this guide to determine applicable antenna types and the RF output power allowed. 1.1 Transceiver Features The LN200 maximizes performance and flexibility in wireless networks, offering the following key features: Selectable frequency (216-222MHz) Selectable bandwidth (6.25kHz, 12.5kHz, 25.0kHz, 50kHz) Selectable modem choices (CPFSK, QPSK, 16QAM, 64QAM) RSSI and EVM readback indicators Store-and-Forward repeater operation Same hardware for Master, Remote, or Store-and-Forward configurations Supports RS/EIA-232(TTL), Ethernet, and USB user interfaces Operates at 5.25 VDC at the MiniPCIe card edge power connections and 10-60Vdc at the 3-pin power connector. Figure 1. LN200 Transceiver Module (Mini PCI-Express Card Edge for Data/Power/& I/O and J700 Antenna) NOTE: Some features may not be available on all units, based on the options purchased, or regulatory constraints in the country of operation. MDS LN200 Integrator’s Guide [1] 05‐6949A01, revision 3 2.0 INSTALLATION The transceiver is designed for installation in existing electronic equipment. The I/O and 5.25v power connections are made through the Mini PCI-Express card edge. The 10-60v power is provided through a separate 3-pin connector on the bottom of the module. The transceiver mounts to the host heatsink assembly using two #4 screws inside the RF can area. The required heatsink contact area on the bottom surface of the PCB has the solder mask removed for proper heat transfer. Only one cable connection is required to the radio for the J700 Antenna connector. The module has three optionally populated status LEDs (CR100, CR101, and CR1000) that indicate operating mode details. These LEDs provide important information that is useful during startup and optimization of the radio link. Antennas used with the radio can be either a Yagi directional type (often used at remote sites) or an omni-directional type used for short range applications or at Master stations. Contact your sales representative for information on available antennas. Follow these steps to install the transceiver module: 1. Power down the Host assembly the module is being installed in to. 2. Mate the MiniPCIe card edge of the module into the socket on the Host assembly. 3. Secure the module to the heatsink surface using two #4 screws through the mounting holes in the corners of the RF can area on the radio’s PC board. 4. Install the RF shield over the transceiver section. 5. Select and install an appropriate antenna and feedline for your system coverage requirements. 6. Connect the antenna coaxial lead to J700 on the module. It accepts a Type-TNC male coaxial connector. 7. Host Power Supply Requirements: a. Input power applied on the 52-pin connector (J1100) must be a regulated 5.25 Vdc (-/+0.05 V). b. Input power applied on 3-pin connector (J900) must not exceed the range 10.0-60.0Vdc i. Nominal Input power on J900 is in the range 12-52Vdc - FCC CFR 47 2.1055(d)(1) See Table 1 for power supply interface connections. 52-Pin GE MDS NIC Card Edge Pin Description 1, 6, 7, 10, 11, 13, 12, 14, 16, 19, 20, 23, 25, 28, 30, 31, 32, 33, 36, 38, 42, 44, 45, 46, 47, 48, 49, 51 2, 24, 39, 41, 52 3, 5, 8, 17, 22 4, 9, 15, 18, 21, 26, 27, 29, 34, 35, 37, 40, 43, 50 GPIO (Includes Ethernet & Serial) 3-Pin GE MDS (J900) connector Pin Description GND 2, 3 +10.0-60.0V *Consult Factory Documentation for specific details +5.25V NC GND Table 1. LN200 Power Supply Connections MDS LN200 Integrator’s Guide [2] 05‐6949A01, revision 3 8. Set the radio’s basic configuration with a PC terminal through the Host system. The four essential settings for all transceivers are (See Section 3 for commands): Frequency Bandwidth Modem Power 9. In a normally operating system, you will see the CR101 POWER LED turn on at start-up. 10. Optimize the installation by checking: Antenna aiming and RSSI check Optimal modem rate setting 3.0 RADIO PROGRAMMING There are no manual adjustments on the radio. All programming and control is performed through a PC connected to the Host platform that interfaces with the radio’s J1100 MiniPCIe card edge connector. 3.1 User Commands The following tables provide descriptions of the various user commands for the transceiver. Command Description ABOUT Displays NIC version build time and date. Displays all available commands. Software reset. Display the NIC serial number. Display/set NIC modem selection. Display/set NIC symbol baud rate selection. Read/write test address. Starts a Packet Error Rate Test. HELP RESET SER MODEM BAUD TEST ADDR TEST PER UPTIME MDM KEY MDM KEYR MDM KEYLO MDM DKEY MDM PRBURST MDM RSSI! TX [val] RX [val] TCXO [arg1] TCXO CAL [arg1] Display the amount of time since last power cycle. Transmits un‐modulated CW Transmits modulated random data Transmits pass through of LO through TX chain Disables active transmission Transmits a modulated random data burst of 511 bytes, useful for training the receiver equalizer Instantaneous RSSI reading Read/write TX frequency Read/write RX frequency Change TCXO tuning voltage Calibrate TCXO tuning voltage Notes [4QAM, 16QAM, 64QAM] [4800,9600,10000,16000,20000,40000] [0‐7] Address used for tests (e.g. PER) [‐a] Destination test address [‐n] Number of packets to send [‐l ] Length of each packet dB [val] ‐ frequency in MHz [val] ‐ frequency in MHz [arg1] ‐ Tuning voltage in V [arg1] ‐ Tuning voltage in V Table 2. LN200 User Commands MDS LN200 Integrator’s Guide [3] 05‐6949A01, revision 3 4.0 DC INPUT REQUIREMENTS 4.1 Power Consumption Ratings The module has the following nominal power consumption ratings when operated at the required (V_NIC) input voltage of 5.25 Vdc (-0.05/+0.05 V tolerance) and the required secondary input voltage of 10.0-60.0 Vdc on J900: Active Receive Mode: 130mA Transmit Mode (Worst Case Load): 1.3 Amperes Power Regulation must be met by OEM to satisfy LMA conditions: OEM Integrator should consult with Product Support for individual circuit implementations. The input voltage on the 3pin J900 connector accepts a wide range and routes to onboard regulator on the LN200 module, but the V_NIC input on the 52-pin connector must be carefully regulated. At minimum, OEM Integrators must regulate the DC voltage applied to +5.25 Vdc (V_NIC), with a tolerance of -0.05/+0.05 Vdc. This can be achieved using a voltage regulator similar to the Texas Instruments LMR12020, which is a precision DC regulator. The external +5.25 Vdc input is connected via pins 2, 24, 39, 41, and 52 of the 52 pin MiniPCIe card edge connector. The transmitter uses a closed-loop power detection circuit that ensures the peak RF power will never exceed +41.3dBm. The input voltage range of the LMR12020 device in this configuration is 10V to 15V. Using switched-mode power conversion technology, the LMR12020 can step down to voltages as low as 1.13V from a 10V input bus, with typically less than 1 W of power dissipation. The output voltage must be set to a voltage of 5.25V, using an external trim resistor. Operating features of the TI device include cycle-by-cycle current limiting, under-voltage lockout (UVLO), on/off inhibit, output overcurrent protection, and over-temperature protection. For example purposes, a circuit employing this method of regulation is shown below in schematic form. 5.0 REGULATORY AND RF OUTPUT POWER REQUIREMENTS 5.1 Technical Assistance Factory technical assistance is available by contacting GE MDS during business hours (8:30 AM to 6:00 PM Eastern Time). Use one of the following means to contact the factory: Telephone: (585) 241-5510 FAX: (585) 242-8369 E-mail: gemds.techsupport@ge.com Web: www.gemds.com MDS LN200 Integrator’s Guide [4] 05‐6949A01, revision 3 5.2 Regulatory Information, LN200 Module FCC Part 15 Notice This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received; including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment Servicing Precautions When servicing energized equipment, be sure to wear appropriate Personal Protective Equipment (PPE). During internal service, situations could arise where objects accidentally contact or short circuit components and the appropriate PPE would alleviate or decrease the severity of potential injury. When servicing radios, all workplace regulations and other applicable standards for live electrical work should be followed to ensure personal safety. Manual Revision and Accuracy This manual was prepared to cover a specific version of firmware code. Accordingly, some screens and features may differ from the actual unit you are working with. While every reasonable effort has been made to ensure the accuracy of this publication, product improvements may also result in minor differences between the manual and the product shipped to you. If you have additional questions or need an exact specification for a product, please contact GE MDS, using the information provided in section 5.1 Technical Assistance above. Environmental Information The manufacture of this equipment has required the extraction and use of natural resources. Improper disposal may contaminate the environment and present a health risk due to hazardous substances contained within. To avoid dissemination of these substances into our environment and to limit the demand on natural resources, we encourage you to use the appropriate recycling systems for disposal. These systems will reuse or recycle most of the materials found in this equipment in a sound way. Please contact GE MDS or your supplier for more information on the proper disposal of this equipment. Product Test Data Sheets Test Data Sheets showing the original factory test results for this unit are available upon request from the GE MDS Quality Leader. Contact the factory using the information at the back of this manual. Serial numbers must be provided for each product where a Test Data Sheet is required. Grounding Requirements To minimize the chance of damage to the unit and connected equipment, a safety ground (NEC Class 2 compliant) is recommended which bonds the antenna system, chassis, power supply and connected data equipment to a singlepoint ground, keeping all ground leads as short as possible. Normally, the unit is adequately grounded if the supplied mounting brackets are used to mount it to a well-grounded metal surface. If the unit is not mounted to a grounded surface, it is recommended that a safety ground wire be attached to one of the mounting brackets or a screw on the enclosure. The use of a lightning protector is recommended where the antenna cable enters the building. Bond the protector to the tower/support ground, if possible. All grounds and cabling must comply with applicable codes and regulations. MDS LN200 Integrator’s Guide [5] 05‐6949A01, revision 3 FCC Limited Modular Approval Notice This device is offered as an FCC Licensed Limited Modular Transmitter (LMA). Applicable rule parts include Part 90, 95 and Part 80. The transmitter module is approved for use only with specific antenna, cable and output power configurations that have been tested and approved for use when installed in devices approved by third-party OEMs, or produced by the Grantee (GE MDS). Modifications to the radio, the antenna system, or power output, that have not been explicitly specified by the manufacturer are not permitted, and may render the radio non-compliant with applicable regulatory authorities. When this module is placed inside an enclosure, a durable label must be affixed to the outside of the final host device and shall be labeled with “Contains FCC ID: E5MDS-LN200, Contains IC: 101DLN200” indicating the module’s FCC ID & IC Numbers. Note: A host product is required to comply with all applicable FCC & Industry Canada equipment authorizations regulations and/or requirements and equipment functions not associated with the transmitter module portion. For example requirements for any co-location of additional transmitter with the module and/or at the minimum compliance with FCC part 15B & IC ICES-003; Digital device are the sole responsibility of the OEM integrators for the final host device. RF Exposure Warnings The antenna(s) to be used with this module must be installed with consideration to the guidelines for RF exposure risk to all nearby personnel, and must not be co-located or operating in conjunction with any other antenna or transmitter. Concentrated energy from a directional antenna may pose a health hazard to humans. Do not allow people to come closer to the antenna than the distances listed in the table below when the transmitter is operating. More information on RF exposure can be found online at the following website: http://www.fcc.gov/encyclopedia/radio-frequency-safety and http://www.hc-sc.gc.ca/ewh-semt/consult/_2014/safety_code_6-code_securite_6/final_finale-eng.php Concentré d'énergie à partir d'une antenne directionnelle peut poser un risque pour la santé humaine. Ne pas permettre aux gens de se rapprocher de l'antenne que les distances indiquées dans le tableau ci-dessous lorsque l'émetteur est en marche. Plus d'informations sur l'exposition aux RF peut être trouvé en ligne à l'adresse suivante: http://www.fcc.gov/encyclopedia/radio-frequency-safety et http://www.hc-sc.gc.ca/ewhsemt/consult/_2014/safety_code_6-code_securite_6/final_finale-eng.php Safety Distance LN200 0-5 dBi Antenna Gain * 5-10 dBi 10-11.1 dBi 1.622 meters 2.884 meters 3.273 meters * Values are based on 41.3 dBm at 216.0MHz, using 100% duty cycle. Note that these values include margin for acceptable tolerance and are extremely conservative. QAM modulation peak-to-average ratio and duty cycle due to media access control ensure that this limit is never reached in a real customer-accessible operating mode. Calculations are based on the more restrictive limits associated with Canada Safety Code 6 regulations. Antennas with gain greater than 11.1 dBi are not offered for this device. Installation of the device into portable applications is not authorized. For fixed point-to-point applications all requirements in IC SRSP-501 section 6.3.2 must be followed. Note that the maximum ERP shall be limited to that which is required to achieve system reliability requirements and shall not exceed 125 watts (less where required). Antennas with gain that violate this requirement are not permitted. MDS LN200 Integrator’s Guide [6] 05‐6949A01, revision 3 5.3 RF Output Settings Consult Table 3 for the applicable power settings. The LN200 is a multi-modem system operating between 216222MHz, in channel bandwidths of 6.25kHz, 12.5kHz, 25.0kHz and 50kHz. Modulation choices in each bandwidth include QPSK, 16QAM, and 64QAM. OTA Rate and maximum power is based on the modem choice and the applicable emission mask for the operating frequency. Bandwidth Modem CPFSK QPSK kHz symbols (x1) (x2) per second OTA OTA bps bps 6.25 4800 -9600 12.5 9600 -19200 12.5 10000 -20000 12.5 25.0 25.0 25.0 50 9600 16000 20000 19200 40000 16QAM 64QAM Maximum Comments / Restrictions (x4) (x6) Output Power OTA OTA bps bps 19200 28800 41.3 dBm Max. Rate depends on operating frequency 38400 57600 41.3 dBm Max. Rate depends on operating frequency 40000 60000 41.3 dBm Max. Rate depends on operating frequency 9600 ----32000 64000 96000 -40000 80000 120000 19200 ----80000 160000 240000 41.3 dBm 41.3 dBm 41.3 dBm 41.3 dBm 41.3 dBm Max. Rate depends on operating frequency Max. Rate depends on operating frequency Max. Rate depends on operating frequency Max. Rate depends on operating frequency Max. Rate depends on operating frequency Table 3. LN200 Power Output 5.3 Offered Antennas Consult Table 4 for offered antennas. Part# 97-2027A19 97-4278A24 97-4278A54 97-4278A55 97-4278A56 97-4278A57 Description ANTENNA, YAGI, 216-240MHz, 5 dBd, 3 ELEMENT, NF, TELEWAVE ANT220Y7-WR Yagi 220-250MHz 9.2dBi 215-225 MHz, 6 dBd Yagi 215-225 MHz, 9 dBd Yagi 215-225 MHz, 7 dBi omni ANTENNA, 216-225 MHz, 2 ELEMENT DIPOLE, 5.0 dBd OFFSET GAIN, N MALE TERM Table 4. LN200 offered antennas MDS LN200 Integrator’s Guide [7] 05‐6949A01, revision 3
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : dbare Create Date : 2017:07:07 11:14:55-07:00 Modify Date : 2017:07:07 11:14:55-07:00 XMP Toolkit : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08 Format : application/pdf Title : Microsoft Word - MDS LN200 Integrators Guide rev 3 C2PC.DOCX Creator : dbare Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 11.0 (Windows) Document ID : uuid:2e91712a-6146-4aeb-914e-39c5a5f9477e Instance ID : uuid:cf2e5b08-37eb-479e-9ee8-6a492881dcc6 Page Count : 7EXIF Metadata provided by EXIF.tools