1.0 INTRODUCTION05-4953A01, Rev. 01 GE MDS WiYZ Remote Quick Start Guide 1MDS WiYZ RemotePublication No. 05-4953A01, Rev. 01The GE MDS WiYZ platform allows the connection of process sen-sors to a wireless network. Wirelessly networked sensors allow monitoring and control of equipment and processes without the infrastructure requirements of a hard-wired system. The WiYZ plat-form’s IP65 Outdoor Rating allows installation of the gateway and remotes outdoors, if required.In addition to these instructions, the MDS WiYZ System Reference Manual (05-4954A01) provides helpful guidance on WiYZ systems and menus. Also refer to the MDS WiYZ Gateway Quick Start Guide (05-4888A01). Electronic copies of all user documents and data sheets are available free of charge at www.GEmds.com.1.1 WiYZ RemoteThe WiYZ Remote is an industrial wireless solution for monitoring signals from directly connected sensors and other signaling devices. It provides robust, versatile communications even in harsh environments and at sites with limited power and communi-cation facilities.The unit’s self-contained design allows for quick installation and deployment without the need for additional accessories. The WiYZ Remote automatically determines communication routes with the WiYZ Gateway.Figure 1. WiYZ Remote1.2 Typical ApplicationThe WiYZ system allows the user to connect a network of sensors wirelessly, and to access collected sensor data through a variety of backhaul WAN interfaces.The WiYZ Remotes monitor analog signals from directly con-nected sensors and other signaling devices, such as warehouse video cameras, tank level sensors, and OEM instruments.1.3 Hardware Input/Output ConfigurationsYou can order the WiYZ Remote with four different hardware I/O configurations:1.3.1 TRNR_PRD-72This device supports a low voltage I/O set:• Two digital inputs (0 -5 VDC to 24 VDC)• Two digital outputs (2 A at 24 VDC)• Two analog voltage inputs (0-100 mV)• One 6 V (40 mA) sensor power supply output1.3.2 TRNR_PRD-74This device supports a high voltage I/O set:• Two digital inputs (0 -5 VDC to 24 VDC)• Two digital outputs (2 A at 24 VDC)• Two analog voltage inputs (0-5 V)• One 6 V (40 mA) sensor power supply output1.3.3 TRNR_PRD-77This device supports a current input I/O set:• Two digital inputs (0 -5 VDC to 24 VDC)• Two digital outputs (2 A at 24 VDC)• Two analog current inputs (0-22 mA)• One 24 V (40 mA) sensor power supply output1.3.4 TRNR_PRD-78This device supports a current output I/O set:• Two digital inputs (0 -5 VDC to 24 VDC)• Two digital outputs (2 A at 24 VDC)• Two analog current outputs (4-20 mA)• One 24 V (40 mA) sensor power supply output2.0 HARDWARE INSTALLATIONRefer to Figure 2 on Page 3 for component locations.2.1 COM1 (J602) RS232 Diagnostic PinoutsRJ11 Pin Signal Direction4 Transmit Data (TXD) Output5 Receive Data (RXD) Input6 Ground (GND) InputPRELIMINARY

Navigation menu