PROPANE CONVERSION INSTRUCTIONS
31-10778-2 02-17 GEA
CGS990
CONVERTING THE PRESSURE REGULATOR
CONVERTING THE COOKTOP BURNERS
CONVERTING THE OVEN BURNERS
(on gas oven models only)
PROPANE CONVERSION INSTRUCTIONS
PROPANE
NAT
Rotate cap counter-
clockwise to loosen
Cap assembly
WARNING This conversion must be performed
E\DTXDOL¿HGLQVWDOOHURUJDVVXSSOLHULQDFFRUGDQFH
with the manufacturer’s instructions and all codes and
UHTXLUHPHQWVRIWKHDXWKRULW\KDYLQJMXULVGLFWLRQ)DLOXUH
WRIROORZ$//LQVWUXFWLRQVFRXOGUHVXOWLQVHULRXVLQMXU\RU
SURSHUW\GDPDJH7KHTXDOL¿HGDJHQF\SHUIRUPLQJWKLV
ZRUNDVVXPHVUHVSRQVLELOLW\IRUWKHFRQYHUVLRQ
WARNING
7KHIROORZLQJDGMXVWPHQWVPXVWEHPDGH
EHIRUHWXUQLQJRQWKHJDVWRWKHEXUQHU)DLOXUHWRGRVRFRXOG
UHVXOWLQVHULRXVLQMXU\GXHWRKLJKÀDPHVDQGWR[LFIXPHV
WARNING
Do not operate the cooktop or oven
EXUQHUVRIWKLVUDQJHZKHQXVLQJSURSDQHERWWOHGJDV
EHIRUHFRQYHUWLQJWKHSUHVVXUHUHJXODWRUDQGEXUQHURUL¿FHV
IRUSURSDQHJDVXVH)DLOXUHWRGRVRFRXOGFDXVHKLJK
ÀDPHVDQGWR[LFIXPHVZKLFKFDQUHVXOWLQVHULRXVLQMXU\
7KHSUHVVXUHUHJXODWRUDQGWKHEXUQHURUL¿FHVDUHVHWIRU
QDWXUDOJDV7RXVHSURSDQHJDVWKHUHJXODWRUDQGEXUQHU
RUL¿FHVPXVWEHFRQYHUWHG
7KHSURSDQHRUL¿FHVIRUWKHFRRNWRSEXUQHUVDUHVKLSSHGRQ
WKHEDFNRIWKHUDQJHLQWKHORFDWLRQVKRZQ
7RDGMXVW\RXUUDQJHIRUXVHZLWKSURSDQHJDVIROORZWKHVH
instructions:
'LVFRQQHFWDOOHOHFWULFDOSRZHUDWWKHPDLQFLUFXLWEUHDNHU
RUIXVHER[
6KXWRIIWKHJDVVXSSO\WRWKHUDQJHE\FORVLQJWKHPDQXDO
VKXWRIIYDOYH
$ 7KHSUHVVXUHUHJXODWRULVORFDWHGRQWKHUHDURIWKH
UDQJH6RPHPRGHOVZLOOKDYHDPHWDOVKLHOGSURWHFWLQJ
WKHUHJXODWRUWKDWPXVWEHUHPRYHGIRUFRQYHUVLRQDQG
UHLQVWDOOHGZKHQFRQYHUVLRQLVFRPSOHWH7KHSUHVVXUH
UHJXODWRULVORFDWHGLQWKHORZHUULJKWKDQGVLGHRIWKHUDQJH
DVYLHZHGIURPWKHUHDU
$ 5HPRYHWKHWRSJUDWHVEXUQHUFDSVDQGEXUQHUKHDGV
% 8VLQJDPPRU´QXWGULYHUUHPRYHWKHWRSEXUQHU
RUL¿FHV7KHVHPD\EHDFFHVVHGWKURXJKWKHEXUQHU
RSHQLQJLQWKHEDVH
BURNER OUTPUT RATINGS: BTU/HR
Propane Gas 10” W.C.P.
BURNER
BTU
RATE ORIFICE
SIZE (mm) COLOR MARKING
5)
5) ´ Black /
5) ´ Black /
5) ´ Black /
5)& ´ White /
/) ´ *UHHQ5HG /
RR ´ 5HG<HOORZ /
LR ´ %OXH%URZQ /
C ´ 2UDQJH*UHHQ /
LOWER
BAKE
´ Green /
833(5
BAKE
´ Red /
BROIL ´ Red /
5HJXODWRU
Location
Rear of Range
2UL¿FH%R[
Location
NOTICE:
,I\RXDUHXVLQJSURSDQHERWWOHGJDVDOODGMXVWPHQWV
GHVFULEHGLQWKHIROORZLQJVWHSVPXVWEHPDGHEHIRUH\RX
PDNHDQ\EXUQHUDGMXVWPHQWV
NOTICE:
7KLVSURGXFWFDQQRWEHFRQYHUWHGWRSURSDQHE\DGMXVWLQJ
WKHRUL¿FHKRRG7KHKRRGPXVWEHUHSODFHGIRUSURSDQH
NOTICE:
6DYHWKHVHRUL¿FHVIRUIXWXUHFRQYHUVLRQEDFNWRQDWXUDOJDV
NOTICE:
6DYHWKHVHRUL¿FHVIRUIXWXUHFRQYHUVLRQEDFNWRQDWXUDOJDV
/HYHUVKRZQFORVHG2YHQ6KXW2IIRQO\
386+/(9(572:$5'5(*8/$7257223(1
% 8QVFUHZWKHSODVWLFSURWHFWHGKH[QXWFDS
&&RPSOHWHO\UHPRYHWKHSURWHFWLYHSODVWLFFDSRIIWKH
WKUHDGHGPHWDOFDS
'7XUQWKHPHWDOFDSVRWKHW\SHRIJDVEHLQJFRQYHUWHGWRLV
GLVSOD\HGDQGUHSODFHWKHSURWHFWLYHSODVWLFFRYHU
( 6FUHZWKHKH[QXWFDSEDFNLQWRWKHUHJXODWRU
(Do not over tighten)
Burner cap
Burner construction
Burner head
Base
2UL¿FHVSXGORFDWHG
WKURXJKWKLVRSHQLQJ
Front right burner (on some models)
2UL¿FHVSXGV
ORFDWHGWKURXJK
WKHVHRSHQLQJV
95
III
Denotes 0.95mm Orifice size openin
g
Denotes LP (Propane) Gas
LR RR
LF
C
RF
LP
Blue/Brown Orange/Green
LP
Green/Red
LP
Red/Yellow
LP
Black
LP
Black
Black
LP
White
LP
LP
RF3
RF1
RFC
RF2
&5HPRYHWKHSURSDQHRUL¿FHVSXGVIURPWKHER[SURYLGHG
7KHSURSDQHRUL¿FHVSXGVKDYHWKHOHWWHU³/´RQWKHWRS
7RDLGLQLGHQWLI\LQJWKHSURSHUORFDWLRQIRUWKHSURSDQH
RUL¿FHVGXULQJDFRQYHUVLRQIURP1DWXUDO*DVWRSURSDQH
*DVSDLQWFRORUFRGHVKDYHEHHQDGGHGWRWKHVLGHRUWRSRI
WKHRUL¿FH6HHWKHFKDUWEHORZ(DFKRUL¿FHPD\DOVRVKRZ
DVHULHVRIHQJUDYHGPDUNV,,,,,,ORFDWHGRQWKHWRS
) )RUWKHH[WUDODUJHEXUQHUOHIWIURQWRQVRPHPRGHOVWKH
FKRNHDQGVHWVFUHZZLOOEHQHHGHG,QVHUWWKHFKRNHLQWR
WKHEXUQHUKHDGWKHQLQVHWWKHVHWVFUHZLQWRWKHEXUQHU
KHDGDQGWLJKWHQVHFXUHO\0DNHVXUHWKHVFUHZKHDGLV
DJDLQVWWKHVKRXOGHUZLWKLQWKHFKRNHQRWFKVRLWGRHVQRW
KDYHDQ\URWDWLRQDOPRYHPHQW
*,QVWDOOWKHROGRUL¿FHVSXGVLQWRWKHPHWDOER[DORQJZLWK
WKHVHLQVWUXFWLRQVDQGUHSODFHRQWRWKHEDFNRIWKHUDQJH
IRUSRVVLEOHIXWXUHFRQYHUVLRQ
',QVWDOOWKHSURSDQHRUL¿FHVLQWKHLUSUHFLVHORFDWLRQV
BAKE BURNER ORIFICE ON DOUBLE OVEN
5HPRYHRYHQGRRURYHQERWWRPDQGEXUQHU2QVRPH
PRGHOVDPHWDOVKLHOGPXVWEHUHPRYHG6RPHPRGHOVZLOO
KDYHDFRYHURYHUWKHEXUQHUWKDWZLOOQHHGWREHUHPRYHG
7RFRQYHUWWRSURSDQHUHSODFHRUL¿FHKRRGZLWKSURSDQH
KRRGVXSSOLHGLQNLWZLWKUDQJH
7RSUHYHQWOHDNDJHPDNHVXUHWKHRUL¿FHVSXGVDUHVHFXUHO\
VFUHZHGLQWRWKHJDVVXSSO\WXEHV
( )RUWKHH[WUDODUJHEXUQHUOHIWIURQWRQVRPHPRGHOVWKH
FKRNHDQGVHWVFUHZZLOOEHQHHGHG,QVHUWWKHFKRNHLQWR
WKHEXUQHUKHDGWKHQLQVHWWKHVHWVFUHZLQWRWKHEXUQHU
KHDGDQGWLJKWHQVHFXUHO\0DNHVXUHWKHVFUHZKHDGLV
DJDLQVWWKHVKRXOGHUZLWKLQWKHFKRNHQRWFKVRLWGRHVQRW
KDYHDQ\URWDWLRQDOPRYHPHQW
Choke
%DVHRQVRPHPRGHOV
6HW6FUHZ
%XUQHU+HDG
2UL¿FHVSXG
ORFDWHGWKURXJK
WKLVRSHQLQJ
([WHQGHG6SXG
Bake
RUL¿FH
hood

/RZVHWWLQJDGMXVWPHQWVPXVWEHPDGHZLWKRWKHUEXUQHUVLQ
RSHUDWLRQRQDPHGLXPVHWWLQJ7KLVSURFHGXUHSUHYHQWVWKH
ORZÀDPHIURPEHLQJVHWWRRORZUHVXOWLQJLQWKHÀDPHEHLQJ
H[WLQJXLVKHGZKHQRWKHUEXUQHUVDUHWXUQHGRQ
$ 7XUQRQDOOVXUIDFHEXUQHUV
% 7XUQWKHNQRERQWKHEXUQHUEHLQJDGMXVWHGWR³/2´/2:
RU³6,0´6,00(5
& 5HPRYHWKHNQREDQGLQVHUWDVPDOOÀDWEODGHVFUHZGULYHU
into the valve shaft as shown and turn clockwise to fully
WLJKWHQGRZQWKHE\SDVVVFUHZ5HSHDWIRUHDFKVFUHZ
)RUWKHWULULQJEXUQHUUHPRYHWKHNQREDQGLQVHUWDVPDOO
ÀDWEODGHVFUHZGULYHULQWRWKHVPDOOKROHWRWKHULJKWRIWKH
YDOYHVKDIWDQGWXUQGRZQWKHE\SDVVVFUHZ
' ,IÀDPHDSSHDUVWRRORZRUXQVWDEOHDGMXVWYDOYHE\SDVV
VFUHZVORZO\WXUQFRXQWHUFORFNZLVH²&&:XQWLODVWDEOH
ÀDPHH[LVWVIRUHDFKEXUQHU5HPHPEHUWZRRWKHUEXUQHUV
PXVWEHWXUQHGRQWRPHGLXP
( $GGLWLRQDOO\IRUHDFKEXUQHUEHLQJDGMXVWHGTXLFNO\RSHQ
DQGFORVHWKHRYHQGRRUIROORZHGE\WKHVWRUDJHGUDZHU
ZKLOHREVHUYLQJÀDPH,IÀDPHLVH[WLQJXLVKHGFRQWLQXH
DGMXVWLQJE\SDVVVFUHZ&&:IRUODUJHUÀDPH5HSHDWGRRU
DQGGUDZHURSHQLQJVXQWLOÀDPHLVVWDEOH
) 5HSODFHWKHNQRE
ADDITIONAL INFORMATIONADJUSTING LOW FLAME SETTING
ON COOKTOP BURNERS
198
III
Denotes 1.98 mm Orifice size opening
Denotes Natural Gas
N
PROPANE CONVERSION INSTRUCTIONS
31-10778-2 02-17 GEA
CGS990
NOTICE:
2QFHWKHFRQYHUVLRQLVFRPSOHWHDQGFRQ¿UPHG¿OORXW
WKHSURSDQHVWLFNHUDQGLQFOXGH\RXUQDPHRUJDQL]DWLRQ
DQGGDWHFRQYHUVLRQZDVPDGH$SSO\WKHVWLFNHUWR
WKHUDQJHQHDUWKHUHJXODWRUWRDOHUWRWKHUVLQWKHIXWXUH
WKDWWKLVDSSOLDQFHKDVEHHQFRQYHUWHGWRSURSDQH,I
FRQYHUWLQJEDFNWRQDWXUDOJDVIURPSURSDQHSOHDVH
remove the sticker so others know the appliance is set to
XVHQDWXUDOJDV
WARNING If you attempt to measure the inner cone
RIWKHÀDPHSOHDVHXVHFDXWLRQEXUQVFRXOGUHVXOW
AIR SHUTTER SETTINGS FOR BAKE AND BROIL BURNERS
8VHDVFUHZGULYHUWRORRVHQWKHDLUVKXWWHUVFUHZ
$GMXVWWKHDLUVKXWWHUVIRUSURSDQHJDVE\URWDWLQJWKHVKXWWHU
WRWKHIXOO\RSHQSRVLWLRQ<RXU¿QDOVHWWLQJVPD\YDU\
5HWLJKWHQWKHDLUVKXWWHUVFUHZ
%DNHDQGEURLOÀDPHPXVWEHFKHFNHGZLWKWKHGRRU
FORVHGWRSURSHUO\FKHFNÀDPHFKDUDFWHULVWLFV
7XUQRQWKHJDV
7XUQRQWKHHOHFWULFLW\
5HLQVWDOOWKHRYHQGRRU
7XUQRQWKHEDNHRUEURLOEXUQHU
$V\RXZDWFKWKHÀDPHZLWKWKHRYHQGRRUFORVHGFKHFN
WKHIROORZLQJWKURXJKWKHRYHQGRRUZLQGRZ
D ,IWKHÀDPHVDUH\HOORZRSHQWKHDLUVKXWWHUPRUH
E ,IWKHÀDPHVEORZDZD\RUÀXWWHUIURPWKHEXUQHUFORVH
WKHDLUVKXWWHUPRUH
%URLO2UL¿FH
+RRG
BROIL BURNER ORIFICE (on some models)
7RFRQYHUWWRSURSDQHUHPRYHEXUQHUDQGUHSODFHRUL¿FHKRRG
ZLWKSURSDQHKRRGVXSSOLHGLQNLWZLWKUDQJH
NOMINAL BURNER SHUTTER POSITION (inches)
BURNER NG PROPANE
833(5%$.(
LOWER BAKE
BROIL
Air shutter
6FUHZ Gap for
6KXWWHU
3RVLWLRQ
&KHFNLQJWKHÀDPHVL]H
,WVKRXOGEHDSSUR[LPDWHO\
´WR´ORQJIRUWKH
EDNHDQGEURLOEXUQHUV
The combustion quality of
WKHEXUQHUÀDPHVQHHGVWR
EHGHWHUPLQHGYLVXDOO\
127(,IEXUQHUÀDPHVORRNOLNH$IXUWKHUDLUVKXWWHU
DGMXVWPHQWLVUHTXLUHG1RUPDOEXUQHUÀDPHVVKRXOG
ORRNOLNH%RU&GHSHQGLQJRQWKHW\SHRIJDV\RX
XVH:LWKSURSDQHJDVVRPH\HOORZWLSSLQJRQWKH
outer cones is normal.
:KHQDOODGMXVWPHQWVDUHPDGHDQGWKHUHVXOWVDUH
satisfactory:
D 5HSODFHWKHRUL¿FH¿WWLQJFRYHU
E 5HSODFHWKHRYHQEDIÀHÀDPHVSUHDGHU
F 5HSODFHWKHRYHQERWWRP
IN SOME CASES:
$ :LWKSURSDQHJDVVRPH\HOORZWLSSLQJRQWKHRXWHUFRQH
LVQRUPDO
% )RUHLJQSDUWLFOHVLQWKHJDVOLQHPD\FDXVHDQRUDQJH
ÀDPHDW¿UVWEXWWKLVZLOOVRRQGLVDSSHDU
SPECIAL NOTE:
7RFRQYHUWWKHRYHQEDFNWRQDWXUDOJDVUHYHUVHWKH
instructions given in making propane adjustments.
(A) Yellow flames:
Further Adjustment
Required
(B) Yellow tips on
outer cones:
Normal for Propane Gas
(C) Soft blue flames:
Normal for Natural Gas
&HQWHUDGMXVWPHQWVFUHZIRUDOOURXQGEXUQHUVH[FHSWWULULQJ
5LJKWDGMXVWPHQWVFUHZIRUWULULQJDQG
UHFWDQJOHEULGJHEXUQHURQVRPHPRGHOV
TOOLS REQUIRED:
$GMXVWDEOHZUHQFK
´2SHQHQGZUHQFK
3KLOOLSVKHDGVFUHZGULYHU
)ODWEODGHGVFUHZGULYHU
EODGHZLWKDSSUR[LPDWHO\´DFURVV
1XWGULYHUV´RUPP
BURNER OUTPUT RATINGS: BTU/HR
NG (Natural) Gas 5” W.C.P.
BURNER
BTU
RATE ORIFICE
SIZE (mm) COLOR MARKING
5)
5) ´ Red 1
5) ´ Red 1
5) ´ Green 1
5)& ´ 1RQH 1
/) ´ Red 1
RR ´ Blue 1
LR ´ Green 1
C ´ Blue 1
LOWER
BAKE
´ Red 1
833(5
BAKE
´ Blue 1
BROIL ´ 2UDQJH 1