GE Sales Guide 20 T0066
2018-06-07-02-16-33 2018-06-07-02-16-33 2018-06-07-02-16-33 70547 As uploads productuploader-uploads 3:
2018-06-06-21-09-55 2018-06-06-21-09-55 2018-06-06-21-09-55 70551 As uploads productuploader-uploads 3:
2018-06-06-23-08-42 2018-06-06-23-08-42 2018-06-06-23-08-42 70549 As uploads productuploader-uploads 3:
2018-05-31-19-08-21 2018-05-31-19-08-21 2018-05-31-19-08-21 70548 As uploads productuploader-uploads 3:
2018-06-06-20-25-57 2018-06-06-20-25-57 2018-06-06-20-25-57 70550 As uploads productuploader-uploads 3:
User Manual: GE Sales Guide GE Appliances Literature Search Results
Open the PDF directly: View PDF .
Page Count: 20
Download | |
Open PDF In Browser | View PDF |
GE Zoneline® Packaged Terminal Air Conditioners Product Guide GE Zoneline ® A Story of American Invention In 1961, the GE Zoneline® PTAC began making its way into hotels and motels across the country, changing the face of comfort on the road. Now, over 50 years later, GE Zoneline has been reinvented in Louisville, Kentucky, to meet the changing needs of America’s hotel industry. The newest GE Zoneline PTACs are engineered to be more reliable, efficient, quieter and incredibly easy to install and maintain. 2 Key benefits GE Zoneline is an industry leader in four categories: reliable Quiet efficient Appearance 3 4 REliable With over one million units installed across the U.S., and with remarkably low service issues, GE Zoneline® PTACs offer unrivaled reliability, consistent performance and constant guest comfort. Unmatched Service & support Our technicians service your Zoneline—and any other GE appliances you have—in no time, so guest comfort is not compromised. feature highlights: Simplified structure | Easy to maintain and service. premium guard corrosion Protection | Special coatings keep each part performing at peak condition, longer. Easy to Service | Zonelines have integrated structural components for easy maintenance and support. Durable design | Rustproof base pan comes standard on all models. Service diagnostics port | Technicians can quickly diagnose problems. Quick connect | The thermostat, central desk control and external fan can be connected in seconds for faster installation and servicing. 5 6 Quiet Quiet operation is a strong suit of GE Zoneline®. It's the industry's quietest PTAC*, so you know your guests will always get a good night’s rest. where it counts Typical outdoor noises such as those from traffic or airports present challenges to hotel owners every day. When tested against leading competitors, GE Zonelines block the most outdoor noise with a sound transmission class of 29*—that’s the highest PTAC STC on the market. That means Zonelines help guests sleep better and can support high guest ratings for hotel and motel properties. BEST STC Guests who are dissatisfied with the room noise or temperature: against leading competitors* 29 (Sound Transmission Class) Standard on all units. Higher is better. 33% Are NOT likely to recommend THE HOTEL** GE Zoneline Amana q series LG Amana friedrich 66% Are NOT likely to return TO THE HOTEL** GE Appliances Zonelines provide quiet comfort for hotel rooms. feature highlights: Baked-on mastic Sound Barrier | A heavy-duty barrier covers the back of the unit for superior sound insulation. Weather barrier system seal | A seal around the perimeter of the unit keeps noise and dirt outside. Two DC fan motors | A motor for each fan reduces noise by dialing in the exact airflow needed for each heating and cooling function. Large Cross-flow blower | Airflow is optimized for a low, balanced sound that is hardly noticeable. Smart fan cooling/heating | Allows the fan to run in either continuous mode during hot weather or cycle mode during the winter months, saving energy and improving guest comfort. * W hen compared to leading competitors. 12,000 BTUh heat pump models tested by independent third-party testing at a national acoustical lab, conducted March 2015 and October 2015, in accordance with ASTM and AHRI standards. The higher the STC rating, the better the unit blocks outside noise. **Clarabridge Ratings and Reviews, for hospitality data collected July 2013 – June 2014. “Americans' biggest complaints about hotels” Forbes Magazine, July 27, 2012 issue. 7 8 Efficient GE Zoneline® PTACs are highly efficient. Zoneline heat pumps can save a property hundreds of dollars per month in utility expenses.* On average Zoneline is 7% more efficient than the leading competitor.** Why it matters Decreasing the energy usage of your properties can save you a lot of money. Since Zoneline PTACs are one of the industry leaders in efficient operation, you’ll be able to cut utility bills without compromising comfort. feature highlights: Reverse cycle defrost | Prolongs heat pump operation, saving energy and money. Electronic temperature limiting | Limits are preset to save energy and avoid excessive temperature swings. Heat & freeze sentinels | Specially designed sentinels protect your property by preventing overheating or freezing. Extensive heat source logic | Smart technology lets each unit automatically select the right heat source to efficiently meet guest needs. Smart programming | Every unit is programmed to balance guest comfort with efficient operation. *Savings depend on region, equipment, structure and other factors. **Zoneline AZ45 and AZ65 series base models, average for EER & COP ratings per AHRI listing May 2016. Efficiency benefits may vary by model and region. 9 10 Appearance GE Zoneline® boasts a slim room front, sleek appearance and light color that blends in seamlessly with any hotel décor and room design. With an industry-standard 42" x 16" cutout and the industry’s slimmest room front, Zoneline provides more open, usable space in the room itself. Streamlined, Inside and out Zoneline is sleek on the outside, and is also more efficiently engineered inside. feature highlights: Backlit, coverless control panel | Attractive display with large, white LED lights and no control panel cover keep this unit looking like new. Sleek appearance | 42" x 16" cutout with a shallow depth provides more usable room space. Light color | Perfectly blends in with modern interior designs. Dimming display | Automatic dimming feature makes sure LED lights are never too bright at night. 11 Feature Highlights GE Zoneline® has a legacy of energy efficiency and guest comfort, thanks to innovative features that property managers love. premium guard Corrosion Protection* Special coatings, paintings and stainless steel ensure lasting performance in challenging environments such as oceanfront properties. BAKED-ON MASTIC SOUND BARRIER A heavy-duty barrier covers the back of the unit for superior sound insulation. MAKEUP AIR* An included secondary system provides continuous outdoor air. The supplemental dehumidification system operates when relative humidity levels rise above 55%. Available on select models. Internal Condensate Removal (ICR)* A system of drainpipes and pump minimizes the amount of condensate draining from the unit when in heat pump mode. Dry air 25* System compatibility Zoneline Dry Air models remove 20%-35% more moisture from the air than standard Zoneline air conditioners**, making them perfect for high humidity climates. ompatible with a wide variety of thermostats C and energy management systems, including central desk control. *Available on select models. **Varies when comparing dehumidification rates of the 7,000/9,000/12,000BTU base models to their Dry Air model counterparts. AZ45 Series electric resistance models only. 12 Blower & DC Motors Heat Pump features Large cross-flow blower, two DC fan motors and smart fan cooling and heating keep the unit quiet while providing efficient heating and cooling performance. Reverse cycle defrost increases efficiency and allows unit to run in heat pump mode longer. Heat & freeze sentinel Electronic touch controls Keeps room from overheating or freezing to increase efficiency and comfort while decreasing operating and maintenance costs. asy-to-use controls with clear LED readout E provide a user-friendly experience. weather barrier system seal Electronic temperature limiting Keeps noise, dirt and grime outside. Prevents expensive overcooling and overheating of rooms. Creates a quieter room and more efficient operation. Limits are automatically set, so seasonal adjustments aren’t necessary. Backup resistance heat delivers quick heating comfort. 13 Zoneline® PACKAGED Terminal air conditioners AZ45 Series | Cooling and electric heat • Digital LED display • Variable vent control • Quiet fans, blowers and motors: – Cross-flow blower – Two DC fan motors – Smart fan cooling • Heat and Freeze Sentinel • Remote thermostat capability • Electronic temperature limiting • Works with central desk control and remote thermostats BASE PREMIUM GUARD CORROSION PROTECTION DRY AIR 25 AZ45E07DAB AZ45E07DAC AZ45E07EAC AZ45E07DAP AZ45E09EAP 7,200/7,000 BTU 13.4/13.4 EER 230/208 Volts 7,200/7,000 BTU 13.4/13.4 EER 230/208 Volts 7,300 BTU 13.4 EER 265 Volts 6,900/6,800 BTU 12.8/12.8 EER 230/208 Volts 9,500 BTU 12.1 EER 265 Volts AZ45E09DAB AZ45E09DAC AZ45E09EAC AZ45E09DAP AZ45E12EAP 9,700/9,600 BTU 12.1/12.1 EER 230/208 Volts 9,400/9,300 BTU 11.8/11.8 EER 230/208 Volts 9,500 BTU 11.6 EER 265 Volts 9,400/9,300 BTU 12.1/12.1 EER 230/208 Volts 11,000 BTU 11.0 EER 265 Volts AZ45E12DAB AZ45E12DAC AZ45E12EAC AZ45E12DAP 11,900/11,800 BTU 11.8/11.8 EER 230/208 Volts AZ45E15DAB 14,900/14,800 BTU 10.5/10.5 EER 230/208 Volts 11,800/11,600 BTU 11.5/11.5 EER 230/208 Volts 11,800 BTU 11.7 EER 265 Volts AZ45E15DAC AZ45E15EAC 14,600/14,500 BTU 10.5/10.5 EER 230/208 Volts 11,200/11,100 BTU 11.5/11.5 EER 230/208 Volts 14,900 BTU 10.7 EER 265 Volts AZ65 Series | Heat pump Includes all resistant heat features, plus: • Staged heating • Heat pump with supplemental resistance heat • Reverse cycle defrost *Coefficient of Performance 14 BASE PREMIUM GUARD CORROSION PROTECTION internal condensate removal AZ65H07DAB AZ65H07DAC AZ65H07EAC AZ65H07DAD AZ65H07EAD 7 ,100/6,900 cooling BTU, 6,200/6,100 heating BTU, 13.0/ 13.0 EER, 4.0/4.0 COP*, 230/208 Volts 7 ,100/7,000 cooling BTU, 6,200/6,100 heating BTU, 13.0/ 13.0 EER, 4.0/4.0 COP*, 230/208 Volts 7,000 cooling BTU, 6,200 heating BTU, 12.8 EER, 3.9 COP*, 265 Volts 7,000/6,900 cooling BTU 6,200/6,000 heating BTU 13.0/13.0 EER 4.0/4.0 COP* 230/208 Volts 7,000 cooling BTU 6,200 heating BTU 12.8 EER 3.9 COP* 265 Volts AZ65H09DAB AZ65H09DAC AZ65H09EAC AZ65H09DAD AZ65H09EAD 9,700/9,600 cooling BTU, 8,100/8,000 heating BTU, 12.2/ 12.2 EER, 3.7/3.7 COP*, 230/208 Volts 9,700/9,600 cooling BTU, 8,100/8,000 heating BTU, 12.2/ 12.2 EER, 3.7/3.7 COP*, 230/208 Volts ,500 cooling BTU, 9 8,100 heating BTU, 11.7 EER, 3.6 COP*, 265 Volts 9,600/9,500 cooling BTU 8,200/8,000 heating BTU 12.0/12.0 EER 3.6/3.6 COP* 230/208 Volts ,500 cooling BTU 9 8,100 heating BTU 11.7 EER 3.5 COP* 265 Volts AZ65H12DAB AZ65H12DAC AZ65H12EAC AZ65H12EAD 1 1,900/11,800 cooling BTU, 10,400/10,300 heating BTU, 11.7/ 11.7 EER, 3.6/3.6 COP*, 230/208 Volts 11,900 cooling BTU, 10,500 heating BTU, 11.6 EER, 3.6 COP*, 265 Volts AZ65H12DAD 12,100/11,900 cooling BTU, 10,500/10,400 heating BTU, 11.9/ 11.9 EER, 3.6/3.6 COP*, 230/208 Volts 11,800/11,600 cooling BTU 10,400/10,200 heating BTU 11.5/11.5 EER 3.5/3.5 COP* 230/208 Volts 11,900 cooling BTU 10,300 heating BTU 11.7 EER 3.4 COP* 265 Volts AZ65H15DAB AZ65H15DAC AZ65H15EAC AZ65H15DAD AZ65H15EAD 1 4,400/14,200 cooling BTU, 13,400/13,300 heating BTU, 10.6/ 10.6 EER, 3.3/3.3 COP*, 230/208 Volts 14,500/14,200 cooling BTU, 13,500/13,300 heating BTU, 10.4/ 10.4 EER, 3.3/3.3 COP*, 230/208 Volts 14,500 cooling BTU, 13,500 heating BTU, 10.6 EER, 3.3 COP*, 265 Volts 14,300/14,100 cooling BTU 13,500/13,400 heating BTU 10.3/10.3 EER 3.2/3.2 COP* 230/208 Volts 14,300 cooling BTU 13,500 heating BTU 10.4 EER 3.2 COP* 265 Volts AZ65 Series | Heat Pump Makeup Air AZ45 Series | Resistant Heat Makeup Air • Delivers 35 CFM of continuous, makeup air makeup air • Conditions incoming air when relative humidity outdoors is above 55% AZ45E09DAM • Quiet operation – Baked-on mastic – Cross-flow blower – Two DC fan motors AZ45E12DAM • Heat & Freeze Sentinels • Electronic temperature limiting • Electronic touch controls with LED display Includes all resistant heat makeup air features, plus: • Reverse heat cycle 9,200/9,100 BTU 11.5/11.5 EER 230/208 Volts 11,600/11,500 BTU 11.4/11.4 EER 230/208 Volts • May reduce the need for rooftop units • Product is built to order NOTE: Because makeup air increases room BTU load requirements and requires additional PTAC cooling or heating, the building’s electrical needs may be impacted. • Boost heat option makeup air AZ65H07DAM AZ65H09DAM† AZ65H12DAM 6,700/6,600 cooling BTU, 6,100/6,000 heating BTU, 12.0/ 12.0 EER, 3.6/3.6 COP*, 230/208 Volts 9,200/9,100 cooling BTU, 8,100/8,000 heating BTU, 11.5/ 11.5 EER, 3.5/3.5 COP*, 230/208 Volts 11,500/11,400 cooling BTU, 10,400/10,300 heating BTU, 11.2/ 11.2 EER, 3.5/3.5 COP*, 230/208 Volts NOTE: Makeup air models listed above are not recommended for installation within two miles of coastal areas. NOTE: It is strongly recommended to install makeup air with wall thermostats. Zoneline® Accessories Wall Case Options Grille Options Retrofit Kits RAB71B, RAB77B Architectural rear grille Extruded aluminum – RAG67 Stamped aluminum – RAG60 RAK40 Deflector kit Extended sleeves also available in 16" and 24" depths High-impact polymer grille Beige – RAG61 Maple – RAG62 Dark Brown – RAG63 Thermostats AZ45 SERIES AZ65 SERIES Cooling with electric heat digital remote thermostat Heat pump digital remote thermostat RAK164D2 RAK164F2 Standard sub-base with power cord included RAK204D15C-15 Amp RAK204D20C-20 Amp RAK204D30C-30 Amp Digital two fan speed thermostat for electric resistance RAK164P2 Cooling with electric heat programmable remote thermostat RAK148D2 RAK148F2 Digital two fan speed thermostat for heat pump RAK148P2 Heat pump programmable remote thermostat Additional accessories available For example, drain kits, adapter, exterior air deflector kits and filters. Visit Zoneline.com for full listing. 15 Power connection kits are required on all ge Zoneline chassis. (See chart below) The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of connecting the unit to the building wiring. If the unit is to be plugged into a receptacle, a line cord kit would be used; if the unit is to be permanently connected, a permanent connection kit would be used. Cord set units of 265 volts must be installed in compliance with National Electrical Code.® power connection Kits Required on all models. See specification information below for heater kWh and branch circuit ampacity. RAK315P/320P/330P RAK315D/320D/330D RAK515D/520D/530D 230/208 volt line cord connection kit 230/208 volt universal power supply kit 265 volt universal power supply kit Also available with short power cords Receptacles/Sub-bases Tandem 230/208V 15 Amp NEMA6-15R Perpendicular 230/208V 20 Amp NEMA6-20R Large tandem 230/208V 30 Amp NEMA6-30R 265V 15 amp NEMA7-15R; receptacle used on 265V sub-base 265V 20 amp NEMA7-20R; receptacle used on 265V sub-base ge Zoneline specifications— heater wattage BTUh size Power connection kit Total watts Heater watts Heater BTUh Total amps Min. circuit Recommended protective device BTUh size Power connection kit Total watts Heater watts Heater BTUh Total amps Min. circuit Recommended protective device 230/208-Volt Line-Cord Connected (P) and Direct Connected Units (D) 7,000/9,000 12,000/15,000 RAK315P & RAK315D 2,410/1,990 2,400/1,960 8,100/6,600 10.5/9.6 15 RAK320P & RAK320D 3,420/2,830 3,400/2,780 11,600/9,400 14.9/13.6 20 RAK330P & RAK330D 4,830/3,990* 4,800/3,930* 16,300/13,400* 21.0/19.2 30 RAK315P & RAK315D 2,430/2,020 2,400/1,960 8,100/6,600 10.6/9.7 15 RAK320P & RAK320D 3,450/2,860 3,400/2,780 11,600/9,400 15.1/13.8 20 RAK330P & RAK330D 4,860/4,020* 4,800/3,930* 16,300/13,400* 21.2/19.3 30 15 amp time-delay fuse or breaker 20 amp time-delay fuse or breaker 30 amp time-delay fuse or breaker 15 amp time-delay fuse or breaker 20 amp time-delay fuse or breaker 30 amp time-delay fuse or breaker 265-Volt Permanent (P, Cord Set) and Direct-Connected Units (D) 7,000/9,000 12,000/15,000 RAK515P & RAK515D 2,440 2,400 8,100 9.1 15 15 amp time-delay fuse or breaker RAK520P & RAK520D 3,450 3,400 11,600 12.9 20 20 amp time-delay fuse or breaker RAK530P & RAK530D 4,850* 4,800* 16,300* 18.1 30 30 amp time-delay fuse or breaker RAK515P & RAK515D 2,460 2,400 8,100 9.3 15 15 amp time-delay fuse or breaker RAK520P & RAK520D 3,470 3,400 11,600 13.1 20 20 amp time-delay fuse or breaker RAK530P & RAK530D 4,870* 4,800* 16,300* 18.4 30 30 amp time-delay fuse or breaker Each line cord kit has an integral Leakage Current Detection and Interruption (LCDI) device as required by National Electrical Code (NEC) and Underwriters Laboratories (UL) for units manufactured after August 1, 2004. Specifications subject to change. Wall case and exterior grille are also required for new construction. *30 AMP heater wattage will be reduced in low fan operation 16 265V 30 amp NEMA7-30R; receptacle used on 265V sub-base Zoneline packaged terminal Air Conditioner specifications 230/208V Models Cooling BTUH EER (BTU/Watt) Dehumidification Pts/Hr Refrigerant type CFM, indoor fan high CFM, indoor fan low Vent CFM (full open) Power factor Sensible heat ratio @ 230 volts Cooling Watts Cooling Amperes, F.L. Amperes, L.R. Weight (Net/Ship) 230/208V Models Cooling BTUH EER (BTU/Watt) Dehumidification Pts/Hr Refrigerant type CFM, indoor fan high CFM, indoor fan low Vent CFM (full open) Power factor Sensible heat ratio @ 230 volts Cooling Watts Cooling Amperes, F.L. Amperes, L.R. Weight (Net/Ship) 230/208V Models Cooling BTUH EER (BTU/Watt) Dehumidification Pts/Hr Refrigerant Type CFM, indoor fan high CFM, indoor fan low Vent CFM (full open) Power factor Sensible heat ratio @ 230 volts Cooling Watts Cooling Amperes, F.L. Amperes, L.R. Weight (Net/Ship) 230/208V Models Cooling BTUH EER (BTU/Watt) Dehumidification Pts/Hr Refrigerant type CFM, indoor fan high CFM, indoor fan low Vent CFM (full open/) Power factor Sensible heat ratio @ 230 volts Cooling Watts Cooling Amperes, F.L. Amperes, L.R. Weight (Net/Ship) AZ45 series (typical) cooling with electric heat AZ45E07DAB AZ45E09DAB AZ45E12DAB AZ45E15DAB 7,200/7,000 13.4/13.4 1.7 R-410A 409 250 33 96% 9,700/9,600 12.1/12.1 2.7 R-410A 409 280 38 98% 11,900/11,800 11.8/11.8 3.5 R-410A 449 270 42 98% 14,900/14,800 10.5/10.5 4.6 R-410A 449 300 47 97% 70% 535/520 2.5/2.6 13.5 90/100 64% 800/790 3.6/3.9 21.0 103/113 60% 1,010/1,000 4.7/5.0 29.5 106/116 63% 1,415/1,405 6.4/6.8 31.5 106/116 AZ45 series cooling with electric heat (Premium Guard Corrosion Protection) AZ45E07DAC AZ45E09DAC AZ45E12DAC AZ45E15DAC 265V Models 7,200/7,000 13.4/13.4 1.6 R-410A 409 250 33 96% 9,400/9,300 11.8/11.8 2.7 R-410A 409 280 38 98% 11,800/11,600 11.5/11.5 3.5 R-410A 449 270 42 98% 14,600/14,500 10.5/10.5 4.6 R-410A 449 300 47 97% 74% 535/520 2.5/2.6 13.5 90/100 64% 795/790 3.5/3.9 21 103/113 60% 1,020/1,005 4.5/4.9 29.5 106/116 63% 1,390/1,380 6.3/6.7 31.5 106/116 AZ45 series cooling with electric heat (Dry Air 25) AZ45E07DAP AZ45E09DAP AZ45E12DAP 6,900/6,800 12.8/12.8 2.3 R-410A 320 230 40.0 96% 9,400/9,300 12.1/12.1 3.4 R-410A 370 280 44.0 97% 11,200/11,100 11.5/11.5 4.2 R-410A 360 270 44 98% 61% 535/530 2.5/2.7 13.5 96/106 58% 775/765 3.5/3.8 21.0 109/119 54% 970/960 4.4/4.7 29.5 112/122 Cooling BTUH EER (BTU/Watt) Dehumidification Pts/Hr Refrigerant type CFM, indoor fan high CFM, indoor fan low Vent CFM (full open) Power factor Sensible heat ratio @ 265 volts Cooling Watts Cooling Amperes, F.L. Amperes, L.R. Weight (Net/Ship) 265V Models Cooling BTUH EER (BTU/Watt) Dehumidification Pts/Hr Refrigerant type CFM, indoor fan high CFM, indoor fan low Vent CFM (full open) Power factor Sensible heat ratio @ 265 volts Cooling Watts Cooling Amperes, F.L. Heating Amperes Weight (Net/Ship) AZ45E07EAC AZ45E09EAC AZ45E12EAC AZ45E15EAC 7,300 13.4 1.7 R-410A 409 250 33 95% 9,500 11.6 2.7 R-410A 409 280 38 94% 11,800 11.7 3.5 R-410A 449 270 42 97% 14,900 10.7 4.6 R-410A 449 300 47 98% 72% 540 2.2 11.7 95/105 67% 815 3.3 16.5 103/113 61% 1,005 4.0 23.5 106/116 59% 1,390 5.4 26.0 107/117 AZ45E09EAP AZ45E12EAP 9,500 12.1 3.5 R-410A 370 280 44 93% 11,000 11.0 4.2 R-410A 360 270 44 97% 58% 780 3.2 16.5 109/119 54% 995 3.9 23.5 112/122 AZ45 series cooling with electric heat (makeup air) AZ45E09DAM AZ45E12DAM 9,200/9,100 11.5/11.5 1.8 R-410A 409 280 35 98% 11,600/11,500 11.4/11.4 3.2 R-410A 449 270 35 98% 78% 800/790 4.8/5.1 21.0 122/132 69% 1,010/1,005 5.8/6.1 29.5 125/135 *Coefficient of Performance Listed by Underwriters Laboratories 17 Zoneline® packaged terminal Air Conditioner specifications 230/208V Models Cooling BTUH EER (BTU/Watt) Dehumidification Pts/Hr Refrigerant type CFM, indoor fan high CFM, indoor fan low Vent CFM (full open) Power factor Sensible heat ratio @ 230 volts Cooling Watts Cooling Amperes, F.L. Amperes, L.R. Reverse cycle heat BTUH Coefficient of Performance Heating Watts Heating Amperes Weight (Net/Ship) 230/208V Models AZ65 (typical) series heat pump with backup electric heat (Premium Guard Corrosion Protection) AZ65H07DAC AZ65H09DAC AZ65H12DAC AZ65H15DAC 265V Models AZ65H07EAC AZ65H09EAC AZ65H12EAC AZ65H15EAC 7,100/7,000 13.0/13.0 1.6 R-410A 409 250 38 96% 9,700/9,600 12.2/12.2 2.6 R-410A 409 300 40 98% 11,900/11,800 11.7/11.7 3.7 R-410A 449 300 45 98% 14,500/14,200 10.4/10.4 4.8 R-410A 449 290 44 97% 73% 545/535 2.5/2.7 13.5 6,200/6,100 4.0/4.0 450/445 2.1/2.2 98/108 68% 795/785 3.6/3.9 21.0 8,100/8,000 3.7/3.7 645/630 2.9/3.1 106/116 62% 1,015/1,005 4.5/4.9 29.5 10,400/10,300 3.6/3.6 845/815 3.8/4.0 104/114 60% 1,390/1,360 6.2/6.7 31.5 13,500/13,300 3.3/3.3 1,195/1,180 5.4/5.7 108/118 Cooling BTUH EER (BTU/Watt) Dehumidification Pts/Hr Refrigerant type CFM, indoor fan high CFM, indoor fan low Vent CFM (full open) Power factor Sensible heat ratio @ 265 volts Cooling Watts Cooling Amperes, F.L. Amperes, L.R. Reverse cycle heat BTUH Coefficient of Performance Heating Watts Heating Amperes Weight (Net/Ship) AZ65 series heat pump with backup electric heat (Internal Condensate Removal) AZ65H07DAD AZ65H09DAD AZ65H12DAD AZ65H15DAD 265V Models Cooling BTUH EER (BTU/Watt) Dehumidification Pts/Hr Refrigerant type CFM, indoor fan high CFM, indoor fan low Vent CFM (full open) Power factor Sensible heat ratio @ 230 volts Cooling Watts Cooling Amperes, F.L. Amperes, L.R. Reverse cycle heat BTUH Coefficient of Performance Heating Watts Heating Amperes Weight (Net/Ship) 7,000/6,900 13.0/13.0 1.6 R-410A 409 250 38.0 96% 9,600/9,500 12.0/12.0 2.6 R-410A 409 300 40.0 98% 11,800/11,600 11.5/11.5 3.7 R-410A 449 300 45.0 98% 14,300/14,100 10.3/10.3 4.8 R-410A 449 290 44.0 97% 73% 535/530 2.5/2.7 13.5 6,200/6,000 4.0/4.0 450/435 2.1/2.2 100/110 68% 800/790 3.6/3.9 21.0 8,200/8,000 3.6/3.6 665/650 3.0/3.2 108/118 62% 1,020/1,005 4.6/4.9 29.5 10,400/10,200 3.5/3.5 870/850 3.8/4.1 106/116 60% 1,385/1,360 6.1/6.6 31.5 13,500/13,400 3.2/3.2 1,235/1,225 5.3/5.6 110/120 230/208V Models AZ65 series heat pump with backup electric heat AZ65H07DAB AZ65H09DAB AZ65H12DAB AZ65H15DAB Cooling BTUH EER (BTU/Watt) Dehumidification Pts/Hr Refrigerant type CFM, indoor fan high CFM, indoor fan low Vent CFM (full open) Power factor Sensible heat ratio @ 230 volts Cooling Watts Cooling Amperes, F.L. Amperes, L.R. Reverse cycle heat BTUH Coefficient of Performance Heating Watts Heating Amperes Weight (Net/Ship) 230/208V Models Cooling BTUH EER (BTU/Watt) Dehumidification Pts/Hr Refrigerant type CFM, indoor fan high CFM, indoor fan low Vent CFM (full open) Power factor Sensible heat ratio @ 230 volts Cooling Watts Cooling Amperes, F.L. Amperes, L.R. Reverse cycle heat BTUH Coefficient of Performance Heating Watts Heating Amperes Weight (Net/Ship) Cooling BTUH EER (BTU/Watt) Dehumidification Pts/Hr Refrigerant type CFM, indoor fan high CFM, indoor fan low Vent CFM (full open) Power factor Sensible heat ratio @ 265 volts Cooling Watts Cooling Amperes, F.L. Amperes, L.R. Reverse cycle heat BTUH Coefficient of Performance Heating Watts Heating Amperes Weight (Net/Ship) 7,100/6,900 13.0/13.0 1.7 R-410A 409 250 38 96% 9,700/9,600 12.2/12.2 2.6 R-410A 409 300 40 98% 12,100/11,900 11.9/11.9 3.7 R-410A 449 300 45 98% 14,400/14,200 10.6/10.6 4.8 R-410A 449 290 44 97% 79% 545/530 2.5/2.7 13.5 6,200/6,100 4.0/4.0 450/440 2.1/2.2 98/108 68% 795/785 3.6/3.8 21.0 8,100/8,000 3.7/3.7 645/630 3.0/3.2 104/114 62% 1,015/1,000 4.5/4.9 29.5 10,500/10,400 3.6/3.6 850/840 3.8/4.0 104/114 60% 1,355/1,335 6.1/6.5 31.5 13,400/13,300 3.3/3.3 1,190/1,180 5.2/5.6 107/117 7,000 12.8 1.5 R-410A 409 250 38 95% 9,500 11.7 2.5 R-410A 409 300 40 94% 11,900 11.6 3.7 R-410A 449 300 45 97% 14,500 10.6 4.8 R-410A 449 290 44 98% 77% 545 2.2 11.7 6,200 3.9 460 1.9 98/108 68% 810 3.3 16.5 8,100 3.6 655 2.8 104/114 62% 1,025 4.0 23.5 10,500 3.6 875 3.5 104/114 60% 1,365 5.3 26.0 13,500 3.3 1,195 4.6 109/119 AZ65H07EAD AZ65H09EAD AZ65H12EAD AZ65H15EAD 7,000 12.8 1.5 R-410A 409 250 38 95% 9,500 11.7 2.5 R-410A 409 300 40 94% 11,900 11.7 3.7 R-410A 449 300 45 97% 14,300 10.4 4.8 R-410A 449 290 44 98% 77% 545 2.2 11.7 6,200 3.9 460 1.9 98/108 68% 810 3.3 16.5 8,100 3.5 670 2.8 104/114 62% 1,015 4.0 23.5 10,500 3.4 885 3.5 104/114 60% 1,375 5.3 26.0 13,500 3.2 1,235 4.6 111/121 AZ65 series heat pump with backup electric heat (makeup air) AZ65H07DAM AZ65H09DAM AZ65H12DAM 6,700/6,600 12.0/12.0 0.5 R-410A 409 250 35 98% 9,200/9,100 11.5/11.5 1.6 R-410A 409 300 35 98% 11,500/11,400 11.2/11.2 2.8 R-410A 449 300 35 98% 90% 555/550 3.8/3.9 13.5 6,100/6,000 3.6/3.5 485/480 3.4/3.6 117/127 80% 800/790 4.8/5.1 21.0 8,100/8,000 3.5/3.5 670/655 4.3/4.5 123/133 72% 1,020/1,010 5.9/6.3 29.5 10,400/10,300 3.5/3.5 860/840 5.2/5.4 123/133 Specifications subject to change. Listed by Underwriters Laboratories 18 Zoneline warranty for the period of GE Appliances will replace one year Any part of the air conditioner which fails due to a defect in materials or workmanship. During this limited one-year warranty, GE will provide, free of charge, all labor and related service costs to replace the defective part. five years Sealed Refrigerating System, if any part of the Sealed Refrigerating System (the compressor, condenser, evaporator, and all connecting tubing) should fail due to a defect in materials or workmanship. During this limited five-year warranty, GE will provide, free of charge, all labor and related service costs to replace the defective part. second through fifth year Fan Motors, Switches, Thermostat, Heater, Heater Protectors, Compressor Overload, Solenoids, Circuit Boards, Auxiliary Controls, Thermistors, Freeze Sentinel, Frost Controls, ICR Pump, Capacitors, Varistors and Indoor Blower Bearing, if any of these parts should fail due to a defect in materials or workmanship. During this additional four-year limited warranty, the customer will be responsible for any labor and related service costs. From the date of the original purchase From the date of the original purchase From the date of the original purchase Zoneline chassis nomenclature A Z 6 5 Zoneline Chassis series 45=cool/electric heat 65=heat pump Unit type E=cooling with electric resistance heat H=heat pump with electric resistance heat H 1 2 Nominal cooling capacity 07=7,000 BTUh cooling 09=9,000 BTUh cooling 12=12,000 BTUh cooling 15=15,000 BTUh cooling Voltage/Phase/Frequency D=230/208 Volt, single phase, 60 Hz E=265 Volt, single phase, 60 Hz DAD Universal power connection Special features B=base unit C=Premium Guard Corrosion Protection D=internal condensate removal (ICR) system (heat pump models only— not for coastal applications) M=Makeup Air P=Dry Air 25 Visit Zoneline.com for more information. Listed by Underwriters Laboratories 19 Listed by Underwriters Laboratories Appliance Park Louisville, KY 40225 Appliance Park of the General Electric Company. GE is a trademark Louisville, KY 40225 Manufactured under trademark license. geappliances.com geappliances.com zoneline.com 888.231.2548 Pub. No. 20-T0066 PC85111
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2016:09:26 14:40:31-04:00 Creator : Adobe InDesign CS6 (Macintosh) Modify Date : 2016:09:27 18:19:04-04:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Instance ID : uuid:87ea90cc-8a76-2d49-a4a1-2c651682c2a7 Original Document ID : adobe:docid:indd:f94fdcbc-1bbb-11df-9d19-de52c0f1ee92 Document ID : xmp.id:DE3787F82E206811822AA09C3BD94A7A Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:DD3787F82E206811822AA09C3BD94A7A Derived From Document ID : xmp.did:FA60CE9843226811822A8E8AE373C7C7 Derived From Original Document ID: adobe:docid:indd:f94fdcbc-1bbb-11df-9d19-de52c0f1ee92 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2016:09:26 14:40:31-04:00 Metadata Date : 2016:09:27 18:19:04-04:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Slug Checksum : 2324825594 Slug Post Script Name : Escrow-Italic Slug Foundry : The Font Bureau Slug Version : 1.000 Slug Outline File Size : 0 Slug Family : Escrow Slug Font Sense 12 Checksum : 2324825594 Slug Font Kind : OpenType - PS Slug Kerning Checksum : 0 Page Count : 20EXIF Metadata provided by EXIF.tools