GE EER3000H02KC User Manual ELECTRIC RANGE Manuals And Guides L0307221

GE Free Standing, Electric Manual L0307221 GE Free Standing, Electric Owner's Manual, GE Free Standing, Electric installation guides

User Manual: GE EER3000H02KC EER3000H02KC GE ELECTRIC RANGE - Manuals and Guides View the owners manual for your GE ELECTRIC RANGE #EER3000H02KC. Home:Kitchen Appliance Parts:GE Parts:GE ELECTRIC RANGE Manual

Open the PDF directly: View PDF PDF.
Page Count: 12

DownloadGE EER3000H02KC User Manual  ELECTRIC RANGE - Manuals And Guides L0307221
Open PDF In BrowserView PDF
Instructions
Installation
[]

Questions?

Call 800.GE.CARES

Electric Ranges

I Free-Standing
(800.432.2737)

or Visit our Website

at: www.GEAppliances.com

I

JBP82,
JBP84,
JB600,JBP35,
JB710,JBP48,
JB905,JBP64,
JB968,JBP66,
JB988 JBP67, JBP68, JBP69, JBP71,
I JBP78,
EER3000,JBP80,
EER3001,
JBP24,
JBP26,

BEFORE YOU BEGIN
Read these instructions
and carefully.

ANTI-TIPDEVICE

_WARNING

completely

for local

inspector's

• IMPORTANT
governing

codes

-To reduce
therisk

of tipping,
the appliance
must be secured
properly
installed
Anti-Tip
bracket packed
with this appliance.

• IMPORTANT - Save
these
instructions

I

use.

by

If the Anti-Tip
device supplied
with the range
does not fit this application,
use the universal
Anti-Tip device WB2X7909.

- Observe
all

and ordinances.

• Note to Installer - Be sure to leave these
instructions
with the Consumer.

-&WARNING -

• Note to Consumer - Keep these
instructions for future reference.

• All ranges

can tip

• Injury to persons

could result

• Skill level - Installation of this appliance
requires basic mechanical
skills.
• Completion

time

• Proper installation
the installer.
• Product failure
is not covered

is the responsibility

If you pull the range out and away from the
wall for any reason, make sure the Anti-Tip
bracket is engaged when the range is pushed
back against the wall.

- Thisapp,ance
must

grounded.

FOR YOUR SAFETY:

AWARNING

-

Before

beginning

the

installation,
switch power off at service panel
and lock the service disconnecting
means to
prevent power from being switched
on
accidentally.
When the service disconnecting
means cannot be locked, securely fasten a
prominent
warning
device, such as a tag, to
the service panel.

229c4053P545-1
31-10556-1

range

• See Installation
Instructions
• Install Anti-Tip bracket packed

of

due to improper installation
under the Warranty.

_WARNING
be properly

with

- 1 to 3 hours

04-03 JR

1

Installation

Instructions

PREPARE TO INSTALL THE RANGE
FOR YOUR SAFETY:

MATERIALS

All rough-in
and spacing dimensions
must be
met for safe use of your range. Electricity
to
the range can be disconnected
at the outlet
without
moving the range if the outlet is in
the preferred
location
(remove
lower drawer).
To reduce

the risk of burns

Tin Snips

YOU MAY NEED

Lag Bolts

Anchor

Sleeves

(For Anti-'rip Bracket Mounted
on Concrete Floors Only)

or fire when

reaching over hot surface elements,
cabinet
storage space above the cooktop should be
avoided.
If cabinet storage space is to be
provided
above the cooktop,
the risk can
be reduced by installing
a range hood that
sticks out at least 5" beyond the front of the
cabinets.
Cabinets installed
above a cooktop
must be no deeper than 13'.'

(UL Approved 40 AMP)
4-Wire Cord
4" Long

Be sure your appliance
is properly
installed
and grounded
by a qualified
technician.

Squeeze Connector
(For Conduit
Installations Only)

OR 3-Wire Cord
4' Long

PARTS INCLUDED

Make sure the cabinets and wall coverings
around the range can withstand the temperatures
(up to 200°F.) generated by the range.
Anti-Tip

Bracket Kit

TOOLS YOU WILL NEED
[]
Drill with 1/8" Bit

Adjustable

Wrench
Tape Measure

Pencil

1/4" Nut Driver

Level

Phillips

Screwdriver

MATERIALS

Remove packaging
materials.
Failure to
remove packaging
materials
could result
in damage to the appliance.

Safety Glasses

Pliers

REMOVE SHIPPING

Flat-blade
Screwdriver

2

Installation

[]

Instructions

PREPARE THE OPENING

See illustrations
dimensions.

for all rough-in

IlL

and spacing

The range may be placed with 0" clearance
(flush) at the back wall and side walls of
the cabinet.

f
*'15"

Acceptable electrical
outlet area.

**30"

Min. _

***6"

Min.
Mn.

Orient the electrical
receptacle so the length
is parallel to the floor.
*0"-_

. !

MINIMUM
DIMENSIONS
BETWEEN COOKTOP,
WALLS AND ABOVE THE COOKTOP:
* Make sure the wall covering,
countertop
and cabinets around the range can
withstand
the heat (up to 200°F)
generated
by the range.
** Allow 30" minimum
clearance
between
surface units and bottom of unprotected
wood or metal cabinet, and 15" minimum
between countertop
and adjacent cabinet
bottom.

NOTE: Use a 4' power cord to prevent
interference
with the storage drawer.
Power cords 41/2to 6' long may have to be
dressed to allow for proper drawer closing.

***

3

Recommended
surfaces.

spacing

to heat-sensitive

Installation

Instructions

ELECTRICAL CONNECTIONS
ELECTRICAL REQUIREMENTS

Use only a 3-conductor
or a 4-conductor
UL-listed range cord. These cords may be
provided
with ring terminals
on wire and
a strain relief device.

CAUTION:

For personal safety,
do not use an extension cord with this
appliance. Remove house fuse or open circuit
breaker before beginning
installation.

A range cord rated at 40 amps with 125/250
minimum
volt range is required.
A 50 amp
range cord is not recommended
but if used,
it should be marked for use with nominal

This appliance
must be supplied
with the
proper voltage and frequency,
and connected
to an individual
properly
grounded
branch
circuit, protected
by a circuit breaker or fuse
having amperage
as specified
on the rating
plate. The rating plate is located above the
storage drawer on the oven frame.
We recommend
you
and hookup of your
qualified
electrician.
the electrician
show
range disconnect
is

13/8" diameter
connection
openings.
Care
should be taken to center the cable and
strain relief within the knockout
hole to keep
the edge from damaging
the cable.
• Because range terminals
are not accessible
after range is in position,
flexible service
conduit or cord must be used.

have the electrical wiring
range connected
by a
After installation,
have
you where your main
located.

NOTE: If conduit
is being
and then to Step 6 or 7.

• On some models, a filter capacitor
may be
connected
between
the black and white
leads on the junction
block.

Check with your local utilities for electrical
codes which apply in your area. Failure to
wire your oven according
to governing
codes
could result in a hazardous
condition.
If there
are no local codes,
and fused to meet
National
Electrical
Latest Edition. You
National

used, go to Step 3D

ALL NEW CONSTRUCTIONS,
MOBILE HOMES AND
INSTALLATIONS
WHERE
LOCAL CODES DO NOT
ALLOW GROUNDING
THROUGH
NEUTRAL,
REQUIRE A 4-CONDUCTOR
UL-LISTED RANGE CORD.

your range must be wired
the requirements
of the
Code, ANSI/NFPA
No. 70can get a copy by writing:

Fire Protection
Association
Batterymarch
Park
Quincy, MA 02269

Effective January 1, 1996, the National
Electrical Code requires that new construction
(not existing) utilize a 4-conductor connection
to an electric range.
When installing an electric range in new
construction,
follow Steps 3 and 5 for 4-wire
connection.
You must use a 3-wire, single-phase
A.C.
208Y/120 Volt or 240/120 Volt, 60 hertz
electrical
system. If you connect to aluminum
wiring,
properly
installed connectors
approved
for use with aluminum
wiring
must be used.
If the electrical
service provided
does not
meet the above specifications,
have a
licensed electrician
install an approved
outlet.

4

Installation

[]

POWER CORD AND
STRAIN RELIEF INSTALLATION

[]

Remove the wire cover
the range) by removing
using a 1/4" nut driver.
Do not discard these

Instructions

[]

For power cord installations
only (see
the next step if using conduit),
assemble
the strain relief in the hole. Insert the
power cord through the strain relief and
tighten. Allow enough slack to easily
attach the cord terminals to the terminal

(on the back of
five (5) screws

block. If tabs are present at the end of
the winged strain relief, they can be
removed for better fit.

screws.

NOTE: Do not install the power cord
without a strain relief. The strain relief
bracket should be installed before

5 screws
to remove
wire cover

reinstalling

the rear range wiring

cover.
Terminal

Back of range
Wire cover
Power

[]

Remove the knockout
ring (1%") located
on bracket directly below the terminal
block. To remove the knockout,
use a
pair of pliers to bend the knockout
ring
away from the bracket and twist until
ring is removed.
/_
_.._k
F_-'_e_/,_:_)_-'-_/"

ring

Bracket

Skip to Step 4 or 5.

[]

Terminal block
(appearance

For conduit installations only, purchase a
squeeze connector matching the diameter
of your conduit and assemble it in the hole.
Insert the conduit through the squeeze
connector and tighten. Allow enough slack to
easily attach the wires to the terminal block.
NOTE: Do not install the conduit without a
squeeze connector. The squeeze connector
should be installed before reinstalling the
rear range wiring cover.

may vary)

Knockout
in bracket

cord

ring removed

5

Skip to Step 6 or 7.

Installation

Instructions

ELECTRICAL CONNECTIONS
[]

(CONT.)

3-WIRE POWER CORD
INSTALLATION

[]

_i WARNING:

A WARN IN G: The
neutral
wire
of

The neutral or ground
wire of the power cord must be connected
to the neutral terminal located in the

the supply circuit must be connected to the
neutral terminal located in the lower center

center of the terminal block. The power
leads must be connected to the lower left
and the lower right terminals of the
terminal block.
[]

of the terminal block. The power leads must
be connected to the lower left and the lower
right terminals of "_e terminal block. The 4th
grounding lead must be connected to the
frame of the range with the ground plate
and the ground screw.

Remove the 3 lower terminal screws
from the terminal
block. Insert the 3
terminal screws through
each power cord
terminal
ring and into the lower terminals
of the terminal
block. Be certain that the
center wire (white/neutral)
is connected
to the center lower position
of the
terminal
block. Tighten screws securely
into the terminal
block.
DO NOT remove
connection.

the ground

[]

Remove

the 3 lower

terminal

screws

from

the terminal
block. Remove the ground
screw and ground plate and retain them.

[]
[]

strap

[]
block
(appearance
may vary)
Terminal
Neutral
terminal

Groun_

4-WIRE POWER CORD
INSTALLATION

Cut and discard the ground strap. DO NOT
DISCARD ANY SCREWS.
Insert the one ground screw into the power
cord ground wire terminal ring, through the
ground plate and into the frame of the range.
Insert the 3 terminal screws (removed earlier)
through each power cord terminal ring and
into the lower terminals of the terminal block.
Be certain that the center wire (white/neutral)
is connected to the center lower position of
the terminal block. -Rghten screws securely
into the terminal block.

,,.,or.

Ground

Terminal
block

strap

Ground

strap

strap

or

Neutral
terminal

plate_

After
Neutral terminal

O

Terminal
block

Power cord

[]

Skip to Step 8 and proceed
installation.

with

Ground
plate
(grounding
to range)

the
Ground
screw

[]

6

Skip to Step 8 and proceed with the installation.

Installation

[]

3-WIRE CONDUIT

[]

Loosen the 3 lower terminal screws from
the terminal block. Insert the center bare

Instructions

INSTALLATION

[]

[]

wire (white/neutral)
tip through the bottom
center terminal block opening. On certain
models, the wire will need to be inserted
through the ground strap opening and then
into the bottom center block opening. Insert
the two side bare wire tips into the lower
left and the lower right terminal block
openings. -lighten the screws until the wire
is firmly secure (approximately
20 inch-lbs.).
NOTE: ALUMINUM

4-WIRE CONDUIT

[]

WIRING:

Aluminum
building
wire may be used
but it must be rated for the correct
amperage
and voltage to make
connection.
Connect wires according
to this Step 6 or Step 7 depending
on
number of wires.

Loosen the three lower terminal screws
from the terminal block. Remove the ground
screw and ground plate and retain them.
Cut and discard the ground strap. DO NOT
DISCARD ANY SCREWS.
Insert the ground bare wire tip between the
range frame and the ground plate (removed
earlier) and secure it in place with the ground
screw (removed earlier). Insert the bare wire
(white/neutral) tip through the bottom center
of the terminal block opening. Insert the two
side bare wire tips into the lower left and the
lower right terminal block openings. -Rghten
the screws until the wire is firmly secure
(approximately
20 inch-lbs.).

Before

//

merminalJ@ieu
block

Terminal
block

Ground

Wire tips

INSTALLATION

II

_\

Ground strap

t

str

__or

_

ral
terminal

After
Terminal
block
Wire tips

Bracket

Ground
plate
(grounding
to range)

Conduit
Ground
screw

Wire used, location
and enclosure
of splices, etc., must conform to good
wiring practices and local codes.

Bracket
[]

Skip to Step 8 and proceed
installation.

with

the
Wire used, location
and enclosure
of splices, etc., must conform to good
wiring practices and local codes.
[]

7

Proceed to Step 8.

Installation

Instructions

INSTALL THE RANGE
I-_REPLACE

THE WIRE COVER

Replace the wire cover on the range back
by sliding its left edge under the retaining
tabs and replacing the five screws removed
earlier. Make sure that no wires are pinched
between the cover and the range back.

t_°re

[]

REMOVE STORAGE

[]

Pull the drawer

[]

Lift the front of the drawer
stops clear the guide.

[]

Remove

out until

cover

t"e

co;er
[]

ANTI-TIP DEVICE INSTALLATION
An Anti-13p bracket is supplied with
instructions
for installation
in a variety of
locations. The instructions
include all
necessary information
to complete the
installation.
Read the Safety Instructions
and the instructions
that fit your situation
before beginning
installation.

Bracket
enter wood

_

Wail plate
_

:

,,\_\\\\\\\\\\EJL
J, _\\\\\\\\\\\\_\\\\\\\\\\\\\\\\\_\_)_
_
Typical installation

of anti-tip bracket attachment

to wall

A WARNING:
• Range must
supplied.

be secured

by Anti-'lip

bracket

• If the Anti-Tip device supplied
with the
range does not fit this application,
use the
universal
Anti-Tip device WB2X7909.
• See instructions

to install (supplied

with bracket).

* Unless properly
installed, the range could
be tipped by stepping
or sitting on the door.
Injury may result from spilled hot liquids
or from the range itself.

8

the drawer.

DRAWER
it stops.
until

the

Installation

[]

LEVEL THE RANGE

[]

Install the oven shelves in the oven and
position the range where it will be installed.

[]

[]

Instructions

[]

FINAL INSTALLATION
CHECKLIST
Check to make sure the circuit breaker is
closed (RESET) or the circuit fuses are
replaced.

Check for levelness by
placing a spirit level or a
cup, partially filled with
Spirit level
water, on one of the
oven shelves. If using a
spirit level, take two
readings--with
the level
placed diagonally
first in one direction
and then the other.

Be sure power

is in service

to the building.

Check to be sure that all packing materials
and tape have been removed.
This will
include tape on metal panel under control
knobs (if applicable),
adhesive
tape, wire
ties, cardboard
and protective
plastic.
Failure to remove these materials could
result in damage to the appliance
once the
appliance
has been turned on and surfaces
have heated.

The front leveling legs can be adjusted
from the bottom and the rear legs can be
adjusted from the top or the bottom.

Check to make sure that the door
I'1

I

_

Lower

and

drawer are parallel to each other and that
both operate smoothly.
If they do not, see
the Owner's Manual for proper replacement.

range

Check to make sure that the rear leveling
leg is fully inserted into the Anti-Tip bracket
and that the bracket is securely installed.
[]

Use an open-end
or adjustable
wrench
to adjust the leveling legs until the range
is level.

[]

OPERATION

CHECKLIST

Turn on one of the surface

[]

REPLACE THE
STORAGE DRAWER

[]

Place the drawer

rail on the guides.

[]

Push the drawer

in until

it stops.

[]

Lift the front of the drawer and push
until the stops clear the guides.

[]

Lower the front of the drawer
in until it closes.

units to observe

that the element glows within 60 seconds.
Turn the unit off when glow is detected. If
the glow is not detected within the time
limit, recheck the range wiring connections.
If change is required, retest again. If no
change is required,
have building wiring
checked for proper connections
and voltage.
Check to make sure the Clock (on models
so equipped)
display is energized.
If a series
of horizontal
red lines appear in the display,
disconnect
power immediately.
Recheck the
range wiring connections.
If change is
made to connections,
retest again. If no
change is required,
have building
wiring
checked for proper connections
and
voltage. It is recommended
that the clock
be changed
if the red lines appear.

in

Be sure all range controls are in the OFF
position
before leaving the range.

and push

9

Notes

10

Notes

11

12

Printed in the United States



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 12
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 3, 2, 1, 4
Create Date                     : Fri Apr 20 13:48:25 2007
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools

Navigation menu