GE EER3000H02KC User Manual ELECTRIC RANGE Manuals And Guides L0307221
GE Free Standing, Electric Manual L0307221 GE Free Standing, Electric Owner's Manual, GE Free Standing, Electric installation guides
User Manual: GE EER3000H02KC EER3000H02KC GE ELECTRIC RANGE - Manuals and Guides View the owners manual for your GE ELECTRIC RANGE #EER3000H02KC. Home:Kitchen Appliance Parts:GE Parts:GE ELECTRIC RANGE Manual
Open the PDF directly: View PDF .
Page Count: 12
Download | |
Open PDF In Browser | View PDF |
Instructions Installation [] Questions? Call 800.GE.CARES Electric Ranges I Free-Standing (800.432.2737) or Visit our Website at: www.GEAppliances.com I JBP82, JBP84, JB600,JBP35, JB710,JBP48, JB905,JBP64, JB968,JBP66, JB988 JBP67, JBP68, JBP69, JBP71, I JBP78, EER3000,JBP80, EER3001, JBP24, JBP26, BEFORE YOU BEGIN Read these instructions and carefully. ANTI-TIPDEVICE _WARNING completely for local inspector's • IMPORTANT governing codes -To reduce therisk of tipping, the appliance must be secured properly installed Anti-Tip bracket packed with this appliance. • IMPORTANT - Save these instructions I use. by If the Anti-Tip device supplied with the range does not fit this application, use the universal Anti-Tip device WB2X7909. - Observe all and ordinances. • Note to Installer - Be sure to leave these instructions with the Consumer. -&WARNING - • Note to Consumer - Keep these instructions for future reference. • All ranges can tip • Injury to persons could result • Skill level - Installation of this appliance requires basic mechanical skills. • Completion time • Proper installation the installer. • Product failure is not covered is the responsibility If you pull the range out and away from the wall for any reason, make sure the Anti-Tip bracket is engaged when the range is pushed back against the wall. - Thisapp,ance must grounded. FOR YOUR SAFETY: AWARNING - Before beginning the installation, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 229c4053P545-1 31-10556-1 range • See Installation Instructions • Install Anti-Tip bracket packed of due to improper installation under the Warranty. _WARNING be properly with - 1 to 3 hours 04-03 JR 1 Installation Instructions PREPARE TO INSTALL THE RANGE FOR YOUR SAFETY: MATERIALS All rough-in and spacing dimensions must be met for safe use of your range. Electricity to the range can be disconnected at the outlet without moving the range if the outlet is in the preferred location (remove lower drawer). To reduce the risk of burns Tin Snips YOU MAY NEED Lag Bolts Anchor Sleeves (For Anti-'rip Bracket Mounted on Concrete Floors Only) or fire when reaching over hot surface elements, cabinet storage space above the cooktop should be avoided. If cabinet storage space is to be provided above the cooktop, the risk can be reduced by installing a range hood that sticks out at least 5" beyond the front of the cabinets. Cabinets installed above a cooktop must be no deeper than 13'.' (UL Approved 40 AMP) 4-Wire Cord 4" Long Be sure your appliance is properly installed and grounded by a qualified technician. Squeeze Connector (For Conduit Installations Only) OR 3-Wire Cord 4' Long PARTS INCLUDED Make sure the cabinets and wall coverings around the range can withstand the temperatures (up to 200°F.) generated by the range. Anti-Tip Bracket Kit TOOLS YOU WILL NEED [] Drill with 1/8" Bit Adjustable Wrench Tape Measure Pencil 1/4" Nut Driver Level Phillips Screwdriver MATERIALS Remove packaging materials. Failure to remove packaging materials could result in damage to the appliance. Safety Glasses Pliers REMOVE SHIPPING Flat-blade Screwdriver 2 Installation [] Instructions PREPARE THE OPENING See illustrations dimensions. for all rough-in IlL and spacing The range may be placed with 0" clearance (flush) at the back wall and side walls of the cabinet. f *'15" Acceptable electrical outlet area. **30" Min. _ ***6" Min. Mn. Orient the electrical receptacle so the length is parallel to the floor. *0"-_ . ! MINIMUM DIMENSIONS BETWEEN COOKTOP, WALLS AND ABOVE THE COOKTOP: * Make sure the wall covering, countertop and cabinets around the range can withstand the heat (up to 200°F) generated by the range. ** Allow 30" minimum clearance between surface units and bottom of unprotected wood or metal cabinet, and 15" minimum between countertop and adjacent cabinet bottom. NOTE: Use a 4' power cord to prevent interference with the storage drawer. Power cords 41/2to 6' long may have to be dressed to allow for proper drawer closing. *** 3 Recommended surfaces. spacing to heat-sensitive Installation Instructions ELECTRICAL CONNECTIONS ELECTRICAL REQUIREMENTS Use only a 3-conductor or a 4-conductor UL-listed range cord. These cords may be provided with ring terminals on wire and a strain relief device. CAUTION: For personal safety, do not use an extension cord with this appliance. Remove house fuse or open circuit breaker before beginning installation. A range cord rated at 40 amps with 125/250 minimum volt range is required. A 50 amp range cord is not recommended but if used, it should be marked for use with nominal This appliance must be supplied with the proper voltage and frequency, and connected to an individual properly grounded branch circuit, protected by a circuit breaker or fuse having amperage as specified on the rating plate. The rating plate is located above the storage drawer on the oven frame. We recommend you and hookup of your qualified electrician. the electrician show range disconnect is 13/8" diameter connection openings. Care should be taken to center the cable and strain relief within the knockout hole to keep the edge from damaging the cable. • Because range terminals are not accessible after range is in position, flexible service conduit or cord must be used. have the electrical wiring range connected by a After installation, have you where your main located. NOTE: If conduit is being and then to Step 6 or 7. • On some models, a filter capacitor may be connected between the black and white leads on the junction block. Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven according to governing codes could result in a hazardous condition. If there are no local codes, and fused to meet National Electrical Latest Edition. You National used, go to Step 3D ALL NEW CONSTRUCTIONS, MOBILE HOMES AND INSTALLATIONS WHERE LOCAL CODES DO NOT ALLOW GROUNDING THROUGH NEUTRAL, REQUIRE A 4-CONDUCTOR UL-LISTED RANGE CORD. your range must be wired the requirements of the Code, ANSI/NFPA No. 70can get a copy by writing: Fire Protection Association Batterymarch Park Quincy, MA 02269 Effective January 1, 1996, the National Electrical Code requires that new construction (not existing) utilize a 4-conductor connection to an electric range. When installing an electric range in new construction, follow Steps 3 and 5 for 4-wire connection. You must use a 3-wire, single-phase A.C. 208Y/120 Volt or 240/120 Volt, 60 hertz electrical system. If you connect to aluminum wiring, properly installed connectors approved for use with aluminum wiring must be used. If the electrical service provided does not meet the above specifications, have a licensed electrician install an approved outlet. 4 Installation [] POWER CORD AND STRAIN RELIEF INSTALLATION [] Remove the wire cover the range) by removing using a 1/4" nut driver. Do not discard these Instructions [] For power cord installations only (see the next step if using conduit), assemble the strain relief in the hole. Insert the power cord through the strain relief and tighten. Allow enough slack to easily attach the cord terminals to the terminal (on the back of five (5) screws block. If tabs are present at the end of the winged strain relief, they can be removed for better fit. screws. NOTE: Do not install the power cord without a strain relief. The strain relief bracket should be installed before 5 screws to remove wire cover reinstalling the rear range wiring cover. Terminal Back of range Wire cover Power [] Remove the knockout ring (1%") located on bracket directly below the terminal block. To remove the knockout, use a pair of pliers to bend the knockout ring away from the bracket and twist until ring is removed. /_ _.._k F_-'_e_/,_:_)_-'-_/" ring Bracket Skip to Step 4 or 5. [] Terminal block (appearance For conduit installations only, purchase a squeeze connector matching the diameter of your conduit and assemble it in the hole. Insert the conduit through the squeeze connector and tighten. Allow enough slack to easily attach the wires to the terminal block. NOTE: Do not install the conduit without a squeeze connector. The squeeze connector should be installed before reinstalling the rear range wiring cover. may vary) Knockout in bracket cord ring removed 5 Skip to Step 6 or 7. Installation Instructions ELECTRICAL CONNECTIONS [] (CONT.) 3-WIRE POWER CORD INSTALLATION [] _i WARNING: A WARN IN G: The neutral wire of The neutral or ground wire of the power cord must be connected to the neutral terminal located in the the supply circuit must be connected to the neutral terminal located in the lower center center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block. [] of the terminal block. The power leads must be connected to the lower left and the lower right terminals of "_e terminal block. The 4th grounding lead must be connected to the frame of the range with the ground plate and the ground screw. Remove the 3 lower terminal screws from the terminal block. Insert the 3 terminal screws through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block. Tighten screws securely into the terminal block. DO NOT remove connection. the ground [] Remove the 3 lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them. [] [] strap [] block (appearance may vary) Terminal Neutral terminal Groun_ 4-WIRE POWER CORD INSTALLATION Cut and discard the ground strap. DO NOT DISCARD ANY SCREWS. Insert the one ground screw into the power cord ground wire terminal ring, through the ground plate and into the frame of the range. Insert the 3 terminal screws (removed earlier) through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block. -Rghten screws securely into the terminal block. ,,.,or. Ground Terminal block strap Ground strap strap or Neutral terminal plate_ After Neutral terminal O Terminal block Power cord [] Skip to Step 8 and proceed installation. with Ground plate (grounding to range) the Ground screw [] 6 Skip to Step 8 and proceed with the installation. Installation [] 3-WIRE CONDUIT [] Loosen the 3 lower terminal screws from the terminal block. Insert the center bare Instructions INSTALLATION [] [] wire (white/neutral) tip through the bottom center terminal block opening. On certain models, the wire will need to be inserted through the ground strap opening and then into the bottom center block opening. Insert the two side bare wire tips into the lower left and the lower right terminal block openings. -lighten the screws until the wire is firmly secure (approximately 20 inch-lbs.). NOTE: ALUMINUM 4-WIRE CONDUIT [] WIRING: Aluminum building wire may be used but it must be rated for the correct amperage and voltage to make connection. Connect wires according to this Step 6 or Step 7 depending on number of wires. Loosen the three lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them. Cut and discard the ground strap. DO NOT DISCARD ANY SCREWS. Insert the ground bare wire tip between the range frame and the ground plate (removed earlier) and secure it in place with the ground screw (removed earlier). Insert the bare wire (white/neutral) tip through the bottom center of the terminal block opening. Insert the two side bare wire tips into the lower left and the lower right terminal block openings. -Rghten the screws until the wire is firmly secure (approximately 20 inch-lbs.). Before // merminalJ@ieu block Terminal block Ground Wire tips INSTALLATION II _\ Ground strap t str __or _ ral terminal After Terminal block Wire tips Bracket Ground plate (grounding to range) Conduit Ground screw Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes. Bracket [] Skip to Step 8 and proceed installation. with the Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes. [] 7 Proceed to Step 8. Installation Instructions INSTALL THE RANGE I-_REPLACE THE WIRE COVER Replace the wire cover on the range back by sliding its left edge under the retaining tabs and replacing the five screws removed earlier. Make sure that no wires are pinched between the cover and the range back. t_°re [] REMOVE STORAGE [] Pull the drawer [] Lift the front of the drawer stops clear the guide. [] Remove out until cover t"e co;er [] ANTI-TIP DEVICE INSTALLATION An Anti-13p bracket is supplied with instructions for installation in a variety of locations. The instructions include all necessary information to complete the installation. Read the Safety Instructions and the instructions that fit your situation before beginning installation. Bracket enter wood _ Wail plate _ : ,,\_\\\\\\\\\\EJL J, _\\\\\\\\\\\\_\\\\\\\\\\\\\\\\\_\_)_ _ Typical installation of anti-tip bracket attachment to wall A WARNING: • Range must supplied. be secured by Anti-'lip bracket • If the Anti-Tip device supplied with the range does not fit this application, use the universal Anti-Tip device WB2X7909. • See instructions to install (supplied with bracket). * Unless properly installed, the range could be tipped by stepping or sitting on the door. Injury may result from spilled hot liquids or from the range itself. 8 the drawer. DRAWER it stops. until the Installation [] LEVEL THE RANGE [] Install the oven shelves in the oven and position the range where it will be installed. [] [] Instructions [] FINAL INSTALLATION CHECKLIST Check to make sure the circuit breaker is closed (RESET) or the circuit fuses are replaced. Check for levelness by placing a spirit level or a cup, partially filled with Spirit level water, on one of the oven shelves. If using a spirit level, take two readings--with the level placed diagonally first in one direction and then the other. Be sure power is in service to the building. Check to be sure that all packing materials and tape have been removed. This will include tape on metal panel under control knobs (if applicable), adhesive tape, wire ties, cardboard and protective plastic. Failure to remove these materials could result in damage to the appliance once the appliance has been turned on and surfaces have heated. The front leveling legs can be adjusted from the bottom and the rear legs can be adjusted from the top or the bottom. Check to make sure that the door I'1 I _ Lower and drawer are parallel to each other and that both operate smoothly. If they do not, see the Owner's Manual for proper replacement. range Check to make sure that the rear leveling leg is fully inserted into the Anti-Tip bracket and that the bracket is securely installed. [] Use an open-end or adjustable wrench to adjust the leveling legs until the range is level. [] OPERATION CHECKLIST Turn on one of the surface [] REPLACE THE STORAGE DRAWER [] Place the drawer rail on the guides. [] Push the drawer in until it stops. [] Lift the front of the drawer and push until the stops clear the guides. [] Lower the front of the drawer in until it closes. units to observe that the element glows within 60 seconds. Turn the unit off when glow is detected. If the glow is not detected within the time limit, recheck the range wiring connections. If change is required, retest again. If no change is required, have building wiring checked for proper connections and voltage. Check to make sure the Clock (on models so equipped) display is energized. If a series of horizontal red lines appear in the display, disconnect power immediately. Recheck the range wiring connections. If change is made to connections, retest again. If no change is required, have building wiring checked for proper connections and voltage. It is recommended that the clock be changed if the red lines appear. in Be sure all range controls are in the OFF position before leaving the range. and push 9 Notes 10 Notes 11 12 Printed in the United States
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 12 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Fri Apr 20 13:48:25 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools