GE GTW330ASK0WW WH00X25414 User Manual WASHER Manuals And Guides 1701245L
User Manual: GE GTW330ASK0WW GTW330ASK0WW GE WASHER - Manuals and Guides View the owners manual for your GE WASHER #GTW330ASK0WW. Home:Laundry & Garment Care Parts:GE Parts:GE WASHER Manual
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
GE Appliances Part Install Instructions WH18X25880 And WH18X25896 Controls ! IMPORTANT SAFETY NOTICE The information in this part instruction is intended for use by individuals possessing adequate backgrounds of electrical, electronic and mechanical experience. Any attempt to repair a major appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use. ! WARNING To avoid personal injury, disconnect power before servicing this appliance. If electrical power is required for diagnosis or test purposes, disconnect the power immediately after performing the necessary checks. RECONNECT ALL GROUNDING DEVICES If grounding wires, screws, straps, clips, nuts, or washers used to complete a path to ground are removed for service, they must be returned to their original position and properly fastened. Parts Included: • • Control Board Instruction Sheet Overview – Procedure for programming new control boards WH18X25880 and WH18X25896 with all LED’s flashing 1. Press Start button. LED’s will stop flashing and the personality ID can be selected. Models with seven segment display will show the personality ID number in the display. Models without seven segment display will show the personality ID number on the status LED’s using binary coding. (See binary chart on reverse side) 2. Press and release the Start button to increment to the next personality ID number. When the end of the ID list is reached the control will wrap around to the beginning of the personality ID number list. 3. When the correct personality ID number is in the display or if the correct status LED’s are lit for the personality ID number needed, press and hold the Start button for three seconds. This will save the personality ID number and the control; will go to an idol state. If an error is made in programming the control, enter Field Service Mode as shown on the back of these instructions and use service mode test 17 to correct. Model Number ID Model Number ID Model Number ID HTW200ASK0 MTW200AMK0 07 GTW460ASJ0 / 02 06 GTW490**J2 and higher 05 GTW220ACK0 HTW240ASK0 00 GTW460ASJ1 / 03 and higher 11 GTW491ASK0 12 GTW330ASK0 08 GTW485ASJ0 10 GTW680BSJ0 /J1 /J2 02 GTW410ASK0 09 GTW485**J2 and higher 14 GTW680**J3 and higher 03 GTW490ACJ0 01 GE Appliances Louisville, KY 40225 WH00X25414 FIELD SERVICE MODE ENTRY From an idle state only (all LEDs off), press and hold Start button while rotating the cycle selection knob 180 degrees (7 clicks) and then release the Start button. – Turning the knob to go to a different test will terminate any current active state. • Once service mode is entered all LEDs will be flashing. – On 7-segment display models: (0) will be displayed for Test (0). – On models without a 7-segment display: All of the status LEDs above the cycle knob will be lit. Exit Field Service Mode • Field service mode will time out after 30 minutes if there is no user activity. • The cycle selection Knob is now used to control the test selection menu. – Rotating the knob clockwise will increment the test numbers in the display. – Rotating the knob counter clockwise will decrement the test number in the display. – Models without 7-segment display: Will display tests using the status lights above the cycle knob in a binary format. (See Binary Chart) Personality Number in Binary Code • Once the test number is selected, pressing Start will begin the selected test. • Models without 7-segment display: Press and hold the Start button for 3 seconds • Models with a 7-segment display: Press Power button SERVICE MODE TEST 17- Change Personality Pressing Start will start the test. Press Start button again and the next valid personality should be displayed. Press and hold the Start button to select the correct personality. Note: Upon entering test 17 for models GTW220 and HTW240 the cycle status LED’s will not be lit for personality 0. 0 1 2 3 5 6 7 8 9 10 11 12 14 GTW220**** HTW240**** GTW490**J0 GTW490**J1 GTW680**J0 GTW680**J1 GTW680**J2 GTW680**J3 and higher GTW490**J2 and higher GTW460**J0 GTW460**J2 MTW200**** HTW200**** GTW330**** GTW410**** GTW485**J0 GTW485**J1 GTW460**J3 and higher GTW491**** GTW485**J2 and higher
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2016:08:29 17:40:37-04:00 Modify Date : 2017:01:17 09:15:19-06:00 Subject : GE | Washer | Procedure for programming new control boards WH18X25880 and WH18X25896 with all LED’s flashing~ Language : en-US Tagged PDF : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : Title : WH00X25414 Description : GE | Washer | Procedure for programming new control boards WH18X25880 and WH18X25896 with all LED’s flashing~ Creator Tool : Microsoft® PowerPoint® 2010 Metadata Date : 2017:01:17 09:15:19-06:00 Producer : Microsoft® PowerPoint® 2010 Document ID : uuid:d68d7a51-d77f-42dc-8d75-e554ea257bc9 Instance ID : uuid:7d4c960a-f7db-491f-a203-086a56cd2479 Page Layout : SinglePage Page Count : 2EXIF Metadata provided by EXIF.tools