GIGA TMS MP90A RFID Multi-ISO Protocol Modules User Manual MP90AH EN A

GIGA-TMS INC. RFID Multi-ISO Protocol Modules MP90AH EN A

Users Manual

Download: GIGA TMS MP90A RFID Multi-ISO Protocol Modules User Manual MP90AH EN A
Mirror Download [FCC.gov]GIGA TMS MP90A RFID Multi-ISO Protocol Modules User Manual MP90AH EN A
Document ID3076267
Application IDAgwc5Fr9vFFiH7G6pVk+Vg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize19.27kB (240814 bits)
Date Submitted2016-07-26 00:00:00
Date Available2016-07-26 00:00:00
Creation Date2016-07-06 14:17:14
Producing SoftwarePDFCreator 2.3.0.103
Document Lastmod2016-07-06 15:15:38
Document TitleMP90AH-EN-A
Document CreatorPDFCreator 2.3.0.103
Document Author: Arthur Huang

TM
MP90A
13.56MHz RFID Multi-ISO Protocol Modules
FEATURES
Supported Protocols
ISO14443A, all bit rates : 106 kbps
ISO15693, all modes
Downlink 1 of 4 and 1 of 256
Uplink 6.6/13/26/53 kbps with 1 & 2 subcarrier
ISO14443B all bit rates : 106 kbps
Supported Standard Format
INTRODUCTION
NFC 1~4 TAGs
Introducing MP90A, GIGA-TMS’s latest released
RFID Module. It not only equips build-in SAM socket,
but also supports multiple ISO standards.
Other than contactless RFID cards, MP90A also
supports SAM card. Users do not need to understand
the complicated ISO/IEC14443 and ISO7816 standard
to operate MP90A. With simple command through
RS232/USB, users may master multiple RFID standards
easily.
MP90A supports wild ranges of
transmission protocols and transponder ICs available on
the market. Designed to meet the requirements of both
secure personal identity verification and supply chain
management applications,
MP90A is ideal for access control, as well as
Automatic Fare Collection (AFC), ticketing, vending and
mobile solutions
ISO14443A
ISO14443B
ISO15693
ISO18092 Felica UID ONLY
Ultra small outline L90 x W30 x H8 mm
Information Support
Support DLL and library
Plug-in fitting for 13.56Mhz
Serial TTL Interface.
Baud Rate 19200,N,8,1
Power supply Active 130mA @5VDC
Firmware Update
Standard Configurations:
Features
MP90AH----USB HID Interface
Enhanced anti-collision algorithm for multi-card
handling
Full 3DES/AES crypto methods
USB and RS232 Interface, 19200 N,8,1
※ Specification is subject to change without notice.
T=CL ISO7816 interface supported
Built in SAM Socket
Full access to data of contactless memory, high
security and microcontroller-based cards
We welcome OEM inquiries
Custom device programming
is available
新北市汐止區康寧街 169 巷 31 號 8 樓
TEL: +886-2-26954214
FAX: +886-2-26954213
e-mail: sales@gigatms.com.tw
http://www.gigatms.com.tw
TM
MP90A
13.56MHz RFID Multi-ISO Protocol Modules
SPECIFICATIONS:
POWER REQUIREMENT
CURRENT REQUIREMENTS
INTERFACE
Supported Protocols
Card Type
FERQUENCY
TRANSPONDER
Baud Rate
DIMENSIONS
WEIGHT
ENVIRONMENT
5V regulated for Operate Voltage . A linear regulator is recommended.
Active 130mA @5VDC W/O Antenna
USB HID Interface
ISO14443A, all bit rates : 106 kbps
ISO15693, all modes
Downlink 1 of 4 and 1 of 256
Uplink 6.6/13/26/53 kbps with 1 & 2 sub-carrier
ISO14443B all bit rates: 106Kbps
ISO 7816 for chip
ISO 14443A
MIFARE™Standard, MIFARE 4k, MIFARE Ultralight, MIFARE Ultralight
C,MIFARE DESFire®,MIFARE DESFire EV1,
ISO 14443B
Smartcard ISO14443B, SRI4K, SRI512
ISO 15693
SIC5600, ICODE-SLI, ICODE-SLI-L, ICODE-SLIS
Read payware and paypass and E-password
NFC TAG 1~4 supportive
ISO18092 Felica READ UID
13.56MHz standard.
Read / Write
19200,N,8,1
DIP: 90(L) x 30(W) x 8(H) mm
1.1g
Operating Temp : -0℃ ~ +50℃
Humidity : 10 ~ 90 % relative
PACKAGE DESCRIPTION
We welcome OEM inquiries
Custom device programming
is available
新北市汐止區康寧街 169 巷 31 號 8 樓
TEL: +886-2-26954214
FAX: +886-2-26954213
e-mail: sales@gigatms.com.tw
http://www.gigatms.com.tw
TM
MP90A
13.56MHz Multiple Read/Write Module with Antenna
PIN DEFINE & PIN DIAGRAMS:
MP90AH- 00
USB
(USB HID )
Description
Pin Numbers
Connector
JST SH 1.0mm
PIN#
+5 VDD
D-
D+
GND
SHIELD
We welcome OEM inquiries
Custom device programming
available
--
TXD (Serial TTL)
RXD (Serial TTL)
is
新北市汐止區康寧街 169 巷 31 號 8 樓
TEL: +886-2-26954214
FAX: +886-2-26954213
e-mail: sales@gigatms.com.tw
http://www.gigatms.com.tw
TM
MP90A
13.56MHz Multiple Read/Write Module with Antenna
Appendix A
We welcome OEM inquiries
Custom device programming
available
is
新北市汐止區康寧街 169 巷 31 號 8 樓
TEL: +886-2-26954214
FAX: +886-2-26954213
e-mail: sales@gigatms.com.tw
http://www.gigatms.com.tw
TM
MP90A
13.56MHz Multiple Read/Write Module with Antenna
Appendix B
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired
operation.
The module must be installed in Windows PC and tablet PC or Andorid tablet PC
IMPORTANT NOTE:
In the event that these conditions can not be met (for example certain laptop configurations or co-location
with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can
not be used on the final product. In these circumstances, the OEM integrator will be responsible for reevaluating the end product (including the transmitter) and obtaining a separate FCC authorization.
End Product Labeling
The final end product must be labeled in a visible area with the following:
“Contains FCC ID: WXAMP90A”.
Manual Information to the End User
The OEM integrator has to be aware not to provide information to the end user regarding how to install
or remove this RF module in the user’s manual of the end product which integrates this module.
We welcome OEM inquiries
Custom device programming
available
is
新北市汐止區康寧街 169 巷 31 號 8 樓
TEL: +886-2-26954214
FAX: +886-2-26954213
e-mail: sales@gigatms.com.tw
http://www.gigatms.com.tw
TM
MP90AH
13.56MHz Multiple Read/Write Module with Antenna
Appendix C
Canada Statement
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following
two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de
brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
The final end product must be labelled in a visible area with the following:
The Industry Canada certification label of a module shall be clearly visible at all times when installed in
the host device, otherwise the host device must be labelled to display the Industry Canada certification
number of the module, preceded by the words “Contains transmitter module”, or the word “Contains”, or
similar wording expressing the same meaning, as follows:
Contains transmitter module IC: 21494-REMEDIRFID1
The module must be installed in Windows PC and tablet PC or Andorid tablet PC
The end user manual shall include all required regulatory information/warning as show in this manual.
We welcome OEM inquiries
Custom device programming
available
is
新北市汐止區康寧街 169 巷 31 號 8 樓
TEL: +886-2-26954214
FAX: +886-2-26954213
e-mail: sales@gigatms.com.tw
http://www.gigatms.com.tw

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Page Mode                       : UseNone
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : PDFCreator 2.3.0.103
Keywords                        : 
Modify Date                     : 2016:07:06 15:15:38+08:00
Create Date                     : 2016:07:06 14:17:14+08:00
Creator Tool                    : PDFCreator 2.3.0.103
Metadata Date                   : 2016:07:06 15:15:38+08:00
Document ID                     : uuid:c7d9a2e2-459c-11e6-0000-9d698bd36793
Instance ID                     : uuid:67f01e85-bbeb-4c25-b437-73c131ce4cfe
Format                          : application/pdf
Title                           : MP90AH-EN-A
Creator                         : Arthur Huang
Description                     : 
Page Count                      : 6
Page Layout                     : SinglePage
Subject                         : 
Author                          : Arthur Huang
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WXAMP90A

Navigation menu