GIGA TMS MP90A RFID Multi-ISO Protocol Modules User Manual MP90AH EN A
GIGA-TMS INC. RFID Multi-ISO Protocol Modules MP90AH EN A
GIGA TMS >
Users Manual
TM MP90A 13.56MHz RFID Multi-ISO Protocol Modules FEATURES Supported Protocols ISO14443A, all bit rates : 106 kbps ISO15693, all modes Downlink 1 of 4 and 1 of 256 Uplink 6.6/13/26/53 kbps with 1 & 2 subcarrier ISO14443B all bit rates : 106 kbps Supported Standard Format INTRODUCTION NFC 1~4 TAGs Introducing MP90A, GIGA-TMS’s latest released RFID Module. It not only equips build-in SAM socket, but also supports multiple ISO standards. Other than contactless RFID cards, MP90A also supports SAM card. Users do not need to understand the complicated ISO/IEC14443 and ISO7816 standard to operate MP90A. With simple command through RS232/USB, users may master multiple RFID standards easily. MP90A supports wild ranges of transmission protocols and transponder ICs available on the market. Designed to meet the requirements of both secure personal identity verification and supply chain management applications, MP90A is ideal for access control, as well as Automatic Fare Collection (AFC), ticketing, vending and mobile solutions ISO14443A ISO14443B ISO15693 ISO18092 Felica UID ONLY Ultra small outline L90 x W30 x H8 mm Information Support Support DLL and library Plug-in fitting for 13.56Mhz Serial TTL Interface. Baud Rate 19200,N,8,1 Power supply Active 130mA @5VDC Firmware Update Standard Configurations: Features MP90AH----USB HID Interface Enhanced anti-collision algorithm for multi-card handling Full 3DES/AES crypto methods USB and RS232 Interface, 19200 N,8,1 ※ Specification is subject to change without notice. T=CL ISO7816 interface supported Built in SAM Socket Full access to data of contactless memory, high security and microcontroller-based cards We welcome OEM inquiries Custom device programming is available 新北市汐止區康寧街 169 巷 31 號 8 樓 TEL: +886-2-26954214 FAX: +886-2-26954213 e-mail: sales@gigatms.com.tw http://www.gigatms.com.tw TM MP90A 13.56MHz RFID Multi-ISO Protocol Modules SPECIFICATIONS: POWER REQUIREMENT CURRENT REQUIREMENTS INTERFACE Supported Protocols Card Type FERQUENCY TRANSPONDER Baud Rate DIMENSIONS WEIGHT ENVIRONMENT 5V regulated for Operate Voltage . A linear regulator is recommended. Active 130mA @5VDC W/O Antenna USB HID Interface ISO14443A, all bit rates : 106 kbps ISO15693, all modes Downlink 1 of 4 and 1 of 256 Uplink 6.6/13/26/53 kbps with 1 & 2 sub-carrier ISO14443B all bit rates: 106Kbps ISO 7816 for chip ISO 14443A MIFARE™Standard, MIFARE 4k, MIFARE Ultralight, MIFARE Ultralight C,MIFARE DESFire®,MIFARE DESFire EV1, ISO 14443B Smartcard ISO14443B, SRI4K, SRI512 ISO 15693 SIC5600, ICODE-SLI, ICODE-SLI-L, ICODE-SLIS Read payware and paypass and E-password NFC TAG 1~4 supportive ISO18092 Felica READ UID 13.56MHz standard. Read / Write 19200,N,8,1 DIP: 90(L) x 30(W) x 8(H) mm 1.1g Operating Temp : -0℃ ~ +50℃ Humidity : 10 ~ 90 % relative PACKAGE DESCRIPTION We welcome OEM inquiries Custom device programming is available 新北市汐止區康寧街 169 巷 31 號 8 樓 TEL: +886-2-26954214 FAX: +886-2-26954213 e-mail: sales@gigatms.com.tw http://www.gigatms.com.tw TM MP90A 13.56MHz Multiple Read/Write Module with Antenna PIN DEFINE & PIN DIAGRAMS: MP90AH- 00 USB (USB HID ) Description Pin Numbers Connector JST SH 1.0mm PIN# +5 VDD D- D+ GND SHIELD We welcome OEM inquiries Custom device programming available -- TXD (Serial TTL) RXD (Serial TTL) is 新北市汐止區康寧街 169 巷 31 號 8 樓 TEL: +886-2-26954214 FAX: +886-2-26954213 e-mail: sales@gigatms.com.tw http://www.gigatms.com.tw TM MP90A 13.56MHz Multiple Read/Write Module with Antenna Appendix A We welcome OEM inquiries Custom device programming available is 新北市汐止區康寧街 169 巷 31 號 8 樓 TEL: +886-2-26954214 FAX: +886-2-26954213 e-mail: sales@gigatms.com.tw http://www.gigatms.com.tw TM MP90A 13.56MHz Multiple Read/Write Module with Antenna Appendix B Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. The module must be installed in Windows PC and tablet PC or Andorid tablet PC IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for reevaluating the end product (including the transmitter) and obtaining a separate FCC authorization. End Product Labeling The final end product must be labeled in a visible area with the following: “Contains FCC ID: WXAMP90A”. Manual Information to the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. We welcome OEM inquiries Custom device programming available is 新北市汐止區康寧街 169 巷 31 號 8 樓 TEL: +886-2-26954214 FAX: +886-2-26954213 e-mail: sales@gigatms.com.tw http://www.gigatms.com.tw TM MP90AH 13.56MHz Multiple Read/Write Module with Antenna Appendix C Canada Statement This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. The final end product must be labelled in a visible area with the following: The Industry Canada certification label of a module shall be clearly visible at all times when installed in the host device, otherwise the host device must be labelled to display the Industry Canada certification number of the module, preceded by the words “Contains transmitter module”, or the word “Contains”, or similar wording expressing the same meaning, as follows: Contains transmitter module IC: 21494-REMEDIRFID1 The module must be installed in Windows PC and tablet PC or Andorid tablet PC The end user manual shall include all required regulatory information/warning as show in this manual. We welcome OEM inquiries Custom device programming available is 新北市汐止區康寧街 169 巷 31 號 8 樓 TEL: +886-2-26954214 FAX: +886-2-26954213 e-mail: sales@gigatms.com.tw http://www.gigatms.com.tw
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Page Mode : UseNone XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : PDFCreator 2.3.0.103 Keywords : Modify Date : 2016:07:06 15:15:38+08:00 Create Date : 2016:07:06 14:17:14+08:00 Creator Tool : PDFCreator 2.3.0.103 Metadata Date : 2016:07:06 15:15:38+08:00 Document ID : uuid:c7d9a2e2-459c-11e6-0000-9d698bd36793 Instance ID : uuid:67f01e85-bbeb-4c25-b437-73c131ce4cfe Format : application/pdf Title : MP90AH-EN-A Creator : Arthur Huang Description : Page Count : 6 Page Layout : SinglePage Subject : Author : Arthur HuangEXIF Metadata provided by EXIF.tools