GN Hearing A S BRIE Wireless Hearing Instrument User Manual
GN Hearing A/S Wireless Hearing Instrument
User manual
USER GUIDE RECEIVER-IN-EAR HEARING INSTRUMENT 400344000-GB-14.11-Rev.A.indd 1 10-12-2014 11:22:24 Hearing instrument type designations for models included in this user guide are: BRIE, FCC ID: X26BRIE, IC: 6941C-BRIE; VE312, FCC ID: X26VE312, IC: 6941C-VE312. Please see page 7 for list of models referring to all types. Statement: This device complies with part 15 of the FCC rules and ICES-003 of the IC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-003(B)/NMB-003(B) of the IC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from the one in which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Changes or modifications can void the user´s authority to operate the equipment. 400344000-GB-14.11-Rev.A.indd 2 10-12-2014 11:22:24 Intended use Generic air-conduction hearing instruments are wearable sound-amplifying devices intended to compensate for impaired hearing. The fundamental operating principle of hearing instruments is to receive, amplify, and transfer sound to the ear drum of a hearing impaired person. The products are in compliance with the following regulatory requirements: • In EU: the device conforms to the Essential Requirements according to Annex I of Council Directive 93/42/EEC for medical devices (MDD) and essential requirements and other relevant provisions of Directive 1999/5/EC (R&TTE). • The declaration of conformity may be consulted at www.resound.com • In US: FCC CFR 47 Part 15, subpart C. • Other identified applicable international regulatory requirements in countries outside EU and US. Please refer to local country requirements for these areas. • In Canada: these hearing instruments are certified under the rules of IC. • Japanese Radio Law and Japanese Telecommunications Business Law Compliance. This device is granted pursuant to the Japanese Radio Law (電波法) and the Japanese telecommunications Business Law (電気通信事業法) This device should not be modified (otherwise the granted designation number will become invalid) • Patents US 7,593,537 US 8,00,849 400344000-GB-14.11-Rev.A.indd 3 10-12-2014 11:22:24 Prescription use of this TSG hearing instrument The TSG module should be used as prescribed by your doctor, audiologist or hearing healthcare professional. In order to avoid permanent hearing damages, the maximum daily usage depends on the level of the generated sound. Should you develop any side effects from using the sound generator, such as dizziness, nausea, headaches, perceived decrease in auditory function or increase in tinnitus perception, you should discontinue use of sound generator and seek medical evaluation. The target population is primarily the adult population over 18 years of age. This product may also be used with children 5 years of age or older. However, children and physically or mentally challenged users will require training by a doctor, audiologist, hearing healthcare professional or the guardian for the insertion and removal of the hearing instrument containing the TSG module. Important notice for prospective sound generator users A tinnitus masker is an electronic device intended to generate noise of sufficient intensity and bandwidth to mask internal noises. It is also used as an aid in hearing external noises and speech. Good health practice requires that a person with a tinnitus condition have a medical evaluation by a licensed physician (preferably a physician who specializes in diseases of the ear) before using a sound generator. Licensed physicians who specialize in diseases of the ear are often referred to as otolaryngologists, otologists or otorhinolaryngologists. The purpose of medical evaluation is to assure that all medically treatable conditions that may affect tinnitus are identified and treated before the sound generator instrument is used. The sound generator instrument is 400344000-GB-14.11-Rev.A.indd 4 10-12-2014 11:22:24 a tool to generate sounds to be used with appropriate counselling and/or in a tinnitus management program to relieve patients suffering from tinnitus. Introduction Congratulations on the purchase of your new hearing instruments. ReSound’s innovative sound technology and design, combined with the customised device programming selected by your hearing care professional, will make hearing a more enjoyable experience. Hearing instruments will enable you to hear sounds that you may not have heard in years because of your hearing loss. Practice and a positive attitude are important in learning to use hearing instruments. Your ReSound instruments have been adjusted according to your individual hearing loss and needs. Some people adjust quickly to wearing hearing instruments in their ears and hearing new sounds; other people may need more time. Please read this manual carefully in order to wholly benefit from the use of your hearing instruments. With proper care, maintenance, and usage, your hearing instruments will aid you in better communication for many years. Ask your hearing care professional if you have any questions. ReSound is a registred trade mark of ReSound A/S 400344000-GB-14.11-Rev.A.indd 5 10-12-2014 11:22:24 Hearing instrument model: Model 61: Battery size 312 Model 62: Battery size 13 Receiver tube length: Dome size: Left serial number: Right serial number: 400344000-GB-14.11-Rev.A.indd 6 10-12-2014 11:22:24 Mini Receiver In-the-Ear (RIE) hearing instruments of type VE312 with FCC ID: X26VE312, IC number 6941C-VE312 and size 312 battery are available in the following variants: LS961-DRW, LS761-DRW, LS561-DRW Receiver-in-the-ear (RIE) hearing instruments of type BRIE with FCC ID X26BRIE, IC number 6941-BRIE and size 13 battery are available in the following variants: LS962-DRW, LS762-DRW, LS562-DRW The identification number for the BRIE and VE312 device models can be found at location “15” as indicated in the illustrations on page 7. 400344000-GB-14.11-Rev.A.indd 7 10-12-2014 11:22:25 Contents Statement: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Prescription use of this TSG hearing instrument . . . 4 Important notice for prospective sound generator users . . . . . . . . . . . . . . . . . . . . . 4 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Getting started . . . . . . . . . . . . . . . . . . . . . . . . . . 12 SmartStart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Inserting/Replacing the battery . . . . . . . . . . . . . 12 Low battery indicator . . . . . . . . . . . . . . . . . . . . . 13 Low battery indicator when paired with wireless accessories only . . . . . . . . . . . . . . . . . 13 Sports lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Inserting/Removing hearing instruments . . . . . . 14 Program and Multi-Function buttons . . . . . . . . . 16 Flight mode* (Wireless models only) . . . . . . . . . 19 Telephone use . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Listen to radio or TV . . . . . . . . . . . . . . . . . . . . . . 21 Using ReSound Hearing Instruments with iPhone®, iPad®, and iPod touch® (ReSound LiNX 2) . . . . . . . . . . . . . . . . . . . . . . . . 21 Cellular phones . . . . . . . . . . . . . . . . . . . . . . . . . 21 PhoneNow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Telecoil (optional) . . . . . . . . . . . . . . . . . . . . . . . . 24 Tele-loop systems . . . . . . . . . . . . . . . . . . . . . . . 24 Direct audio input (optional) . . . . . . . . . . . . . . . . 24 Connecting/Disconnecting audio boots . . . . . . . 25 Care and maintenance . . . . . . . . . . . . . . . . . . . . 26 Daily maintenance . . . . . . . . . . . . . . . . . . . . . . . 27 The receiver tube . . . . . . . . . . . . . . . . . . . . . . . . 28 Cleaning the receiver tubes and domes . . . . . . . 28 Cleaning RIE or moulds . . . . . . . . . . . . . . . . . . . 28 Changing wax guard for receiver tube . . . . . . . . 29 How to apply domes . . . . . . . . . . . . . . . . . . . . . 30 Using ReSound hearing instruments with smart phone apps . . . . . . . . . . . . . . . . . . . . . . . 31 General precautions . . . . . . . . . . . . . . . . . . . . . . 32 400344000-GB-14.11-Rev.A.indd 8 10-12-2014 11:22:25 General warnings . . . . . . . . . . . . . . . . . . . . . . . . 32 Tinnitus Sound Generator (TSG) module . . . . . . 34 User instructions for the TSG module . . . . . . . . 34 The scientific concepts that form the basis for the device . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Technical Specifications . . . . . . . . . . . . . . . . . . . 36 TSG warnings . . . . . . . . . . . . . . . . . . . . . . . . . . 37 TSG precautions . . . . . . . . . . . . . . . . . . . . . . . . 37 TSG warning to hearing healthcare professionals . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Battery warning information . . . . . . . . . . . . . . . . 39 Hearing instrument expectations . . . . . . . . . . . . 39 Warning to hearing aid dispensers (US Only) . . 40 Important notice for prospective hearing aid users (US Only) . . . . . . . . . . . . . . . . 40 Children with hearing loss (US Only) . . . . . . . . . 41 Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . 42 Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . 44 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Warranty and repairs . . . . . . . . . . . . . . . . . . . . . 54 Temperature test, transport and storage information . . . . . . . . . . . . . . . . . . . . . . 54 400344000-GB-14.11-Rev.A.indd 9 10-12-2014 11:22:25 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Receiver tube Receiver Open Dome Receiver Tulip Dome Receiver Power Dome RIE mould Sports lock Battery compartment Receiver Push button Volume Control (optional) LP receiver tube MP receiver tube HP receiver tube Model, and serial number (in battery chamber) UP Receiver/Mould 62 models (type BRIE) 9, 10 14 61 model (type VE312) 15 10 400344000-GB-14.11-Rev.A.indd 10 10-12-2014 11:22:25 3 2) 11 12 13 15 11 400344000-GB-14.11-Rev.A.indd 11 10-12-2014 11:22:26 On Getting started On/Off function 1. When the battery door is closed, the hearing instrument turns on, and the default program will be activated. 2. To turn off the hearing instrument, open the battery door. Use your fingernail to pull it open. Off SmartStart Hearing instruments can be turned on once you have placed them on your ears. If you prefer to turn them on just prior to placing them on your ear, your hearing care professional can activate a function called SmartStart. This function will delay the time in which the hearing instruments turn on after the battery compartment is closed. With SmartStart, a beep will be heard for each second of the delay period. Inserting/Replacing the battery 1. Open the battery door completely by using your fingernail. Remove the used battery if present. 2. Prepare the new battery (please refer to page 7 for information on appropriate battery type/size for your hearing instrument). Remove the protective foil and wait 2 minutes before inserting the battery into the hearing instrument to allow activation of the battery. 3. Insert the new battery with the positive side in the correct position. 4. Gently close the battery door. 12 400344000-GB-14.11-Rev.A.indd 12 10-12-2014 11:22:28 i Tip: 1. Always use new Zinc-Air batteries that have a minimum remaining shelf life of one year. 2. Whenever the hearing instruments are not in use, remember to turn them off to avoid unnecessary battery consumption. Low battery indicator Your hearing care professional can set your hearing instrument to give an acoustical indication when the battery is reaching its end of life. The hearing instrument will reduce amplification and emit a melody if battery power gets too low. This signal will recur every five minutes (every 15 minutes for the LiNX models) until the hearing instrument automatically switches off. It is recommended that you keep spare batteries on hand. Low battery indicator when paired with wireless accessories only Active usage of the ReSound Unite accessories (Remote Control 2, Phone Clip+, TV Streamer 2 and Mini Microphone) requires more battery power from the hearing instruments than when these are working on their own meaning that battery life is highly dependent on the amount of wireless accessory usage. When the battery in the hearing instrument has depleted to a level at which use of the ReSound Unite TV Streamer 2, Phone Clip+ and Mini Microphone cannot be supported, the hearing instrument will play two sets of descending tones. After this, your hearing instrument and ReSound Unite Remote Contro 2l will continue to work as usual, but you will not be able to use your ReSound Unite TV Streamer 2, Phone Clip+ and Mini Microphone. At some point the battery level will not support the remote control either and you will once again hear the descending tones. The hearing instruments will continue to work as usual. Once a new battery is inserted, full operation of the accessories will resume. 13 400344000-GB-14.11-Rev.A.indd 13 10-12-2014 11:22:28 Sports lock The sports lock will be applied or adjusted by your hearing care professional. Inserting/Removing hearing instruments Insertion (custom RIE and UP moulds) 1. Hold the RIE mould between your thumb and index finger and position its sound outlet in your ear canal. 2. Slide the RIE mould all the way into your ear with a gentle, twisting movement. 3. Move the RIE mould up and down and gently press to ensure it is positioned correctly in the ear. Opening and closing your mouth can ease insertion. 4. Make sure the hearing instrument is seated behind the ear. By experimenting, an easier method may be discovered. With proper insertion, hearing instruments should fit snugly but comfortably. If hearing instruments cause irritation of the ears, contact your hearing care professional. Never attempt to modify the shape of the hearing instrument, RIE moulds, or tubing yourself. Tip: It may be helpful to pull the top of your ear back with your opposite hand during insertion to open the ear canal. 14 400344000-GB-14.11-Rev.A.indd 14 10-12-2014 11:22:29 Insertion (domes) 1. Hold the receiver tube where it bends, and gently place the dome into the ear canal. Push the dome far enough into the ear canal so that the receiver tube lies flush with the side of the head. 2. It is important that the tube and the dome fit correctly into your ear. 3. When the dome is placed correctly, you should not be able to see the receiver tube sticking out when facing a mirror. Note: You should never attempt to bend or modify the shape of the receiver tube. Removal (RIE moulds) 1. Grasp the removal string and pull the RIE or UP mould outward. 2. Consult your hearing care professional if you have difficulties removing the hearing instrument. Removal (domes) 1. Hold the receiver tube with your thumb and forefinger and remove the tube. 2. Consult your hearing care professional if you have difficulties removing the hearing instrument. 15 400344000-GB-14.11-Rev.A.indd 15 10-12-2014 11:22:29 Program and Multi-Function buttons If you have a hearing aid with a program button or multi-function button, this will allow you to use up to four different listening programs, each of them suitable for certain situations. Program button (61 models only) Multi-function button (62 models only) Your hearing care professional can fill out the following table for you. Programme Description of when to use 16 400344000-GB-14.11-Rev.A.indd 16 10-12-2014 11:22:30 When using the program or multi-function buttons to switch programs, each press will move the instrument to the next program. For example, if it was in program 1 it will switch to program 2, if it was in program 2 it will switch to program 3 etc. When you close the battery door and switch the instrument on, it will start in program 1. Press the program or multi-function buttons if you want to move to a different listening program. If you have two hearing instruments with the synchronization function enabled, program changes to one instrument will automatically repeat in the second instrument. When a program change is made in one instrument, you will hear the same amount of confirmation beeps in the second instrument. Your instrument has a fully automatic volume control. Therefore, it should not be necessary to control the volume manually. However, in addition to controlling listening programs, the multi-function button (62 models only) provides you with the ability to adjust the amplification to your liking. 17 400344000-GB-14.11-Rev.A.indd 17 10-12-2014 11:22:30 If you have two hearing instruments with the synchronization function enabled and you have the Multifunction Button set for volume control functionality, volume adjustments to one instrument will automatically repeat in the second instrument. When a volume control adjustment is made in one instrument, you will hear a confirmation beep. A beep in the second instrument will follow. The multi-function button is designed to change the volume or listening programs of the hearing instrument, based on different ways it is pressed. If necessary, your hearing care practitioner can change these settings and fill in the following table to indicate the new settings: Multi-function button action Default setting Short press up Increases volume Short press down Decreases volume Long press up (3 seconds) Changes programs Long press down (3 seconds Activates streaming New setting 18 400344000-GB-14.11-Rev.A.indd 18 10-12-2014 11:22:30 i Flight mode* (Wireless models only) When boarding a flight or entering an area where RF transmitters are prohibited, wireless functionality must be deactivated, as it is not allowed to radiate radio signals during flights or in otherwise restricted areas. It is possible to disable wireless operation by opening and closing the battery compartment three times within a ten second period (open-close, open-close, open-close). Your instruments will now be in flight mode. If the hearing instrument is in flight mode, the hearing instrument must have been operating in flight mode for at least 10 seconds before attempting to enable wireless again. it is possible to re-enable wireless operation by opening and closing the battery door once. 10 seconds after this operation is completed, wireless operation will begin again. Note: It is important to wait an additional 15 seconds after wireless function resumes before opening and closing the battery compartment again for any reason. If the battery compartment is opened and closed during this 15 second window, flight mode will resume. *For wireless models only 400344000-GB-14.11-Rev.A.indd 19 19 10-12-2014 11:22:30 Telephone use If your hearing instruments are fit with a receiver open dome or receiver tulip dome, you can probably use the telephone as you normally would by holding it up to your ear canal opening. If your hearing instruments are fit with a receiver power dome or RIE or UP mould, finding the optimal position for holding a telephone while using a hearing instrument may require practice for some individuals, and one or more of the following suggestions may be helpful. 1. Hold the telephone as you would normally. 2. Hold the telephone towards the top of the ear (closer to where the microphones are located). 3. If whistling occurs, it may take a brief moment of holding the telephone in the same position before the hearing instrument adapts and reduces the feedback. 4. Any whistling may also be decreased by holding the telephone slightly away from the ear. 5. Depending on your individual needs, your hearing care professional may activate a programme specifically for telephone use. 20 400344000-GB-14.11-Rev.A.indd 20 10-12-2014 11:22:30 Listen to radio or TV When listening to the TV or the radio, start out by listening to news commentators since they usually speak clearly, then try other programmes. If you find it difficult to listen to TV or radio, your hearing care professional will be able to give you advice on available wireless accessories to enhance your listening capabilities for TV and radio. Using ReSound Hearing Instruments with iPhone®, iPad®, and iPod touch® (ReSound LiNX 2) ReSound LiNX 2 is a Made for iPhone instrument and allows for direct communication and control with an iPhone, iPad, or iPod touch. For assistance in pairing and using these products with your ReSound LiNX 2 device, please contact your hearing care professional or visit our support site at www.resound.com/linx. Cellular phones Your hearing instrument is designed to comply with the most stringent Standards of International Electromagnetic Compatibility. However, not all cell phones are hearing instrument compatible. The varying degree of disturbance can be due to the nature of your particular cellular phone or of your wireless telephony service provider. If you find it difficult to obtain a good result while using your cellular phone, your hearing care professional will be able to give you advice on available wireless accessories to enhance listening capabilities. 21 400344000-GB-14.11-Rev.A.indd 21 10-12-2014 11:22:30 PhoneNow The PhoneNow function, allows your hearing instrument to automatically switch to your telephone programme when a telephone receiver is raised to the ear. When the telephone receiver is removed from the ear, the hearing instrument automatically returns to the previous listening programme. Placement of PhoneNow magnets Place PhoneNow magnet on your telephone receiver to allow operation of the PhoneNow function. In order to place PhoneNow magnet properly: 1. Clean the telephone receiver thoroughly. 2. Hold the telephone vertically, in a position similar to when making a telephone call. 3. Place the magnets just below the telephone receiver. Make sure not to cover the microphone openings. If necessary, move the magnet to another position to improve ease of use and comfort while speaking. 4. If you are not satisfied with the strength of PhoneNow, you can reposition the PhoneNow magnet or add additional PhoneNow magnets.PhoneNow usage Telephones can be used in a normal manner. A short melody will indicate that the PhoneNow feature has automatically switched the hearing instrument to your telephone programme. Initially, you may need to move the telephone receiver slightly to find the best position for reliable PhoneNow activation and good hearing on the telephone. If you have two hearing instruments with the synchronization function enabled, the volume of hearing instrument on the non-phone ear will be turned down. Only use recommended cleaning agent to clean the telephone prior to placing the magnet on the phone in order to obtain best possible adherence. 22 400344000-GB-14.11-Rev.A.indd 22 10-12-2014 11:22:30 i PhoneNow warnings Keep magnets out of reach of pets, children and mentally challenged persons. If a magnet is swallowed, please seek advice from a medical practitioner. 2. The magnet may affect some medical devices or electronic systems. The manufacturer of any magnetically sensitive devices (e.g. pacemakers) should advise you regarding appropriate safety precautions when using your hearing instrument and magnet in close proximity to the medical device or electronic system in question.If the manufacturer cannot issue a statement, we recommend keeping the magnet or a telephone equipped with the magnet 30 cm (12”) away from magnetically sensitive devices (e.g. pacemakers). 1. PhoneNow precautions High distortion during dialing or phoning may mean that the magnet is not in the optimal position relative to the telephone receiver. To avoid the issue, please move the magnet to another place on the telephone receiver. 2. Only use magnets supplied by ReSound. 1. 23 400344000-GB-14.11-Rev.A.indd 23 10-12-2014 11:22:30 Telecoil (optional) If equipped, a telecoil can be activated by your hearing care professional and accessed through one of the additional programmes. A telecoil picks up a telephone’s magnetic signal and converts it to sound. An optional telephone programme may help to improve speech understanding on the telephone. When using a telecoil programme, the receiver of the telephone may need to be held closer to the hearing instrument. The handset of the telephone may need to be moved to slightly different positions in order to find the best reception. Tele-loop systems Many places, such as theatres, houses of worship, and schools are equipped with tele-loop systems. When using a telecoil programme with tele-loop systems, sound is picked up directly and may improve speech understanding. If there is no sound from the hearing instruments in a tele-loop system and with a telecoil programme activated, the tele-loop system may not be turned on or is not operating correctly. If a facility is not equipped with a tele-loop system, sitting as close as possible to the front may be helpful. Direct audio input (optional) Use of direct audio input (DAI), which enables a direct connection of the hearing instruments to items such as television, radio, and remote microphones, may increase speech understanding for some individuals. The sound source is connected to the hearing instruments by a cable or a wireless FM system to the audio boot. This accessory connects to the bottom of the hearing instruments, and once properly clicked into place, the hearing instruments switch to DAI automatically. 24 400344000-GB-14.11-Rev.A.indd 24 10-12-2014 11:22:30 Connecting/Disconnecting audio boots Connecting audio boots 1. Align the tip of the audio boot with the groove just above the battery compartment and below the model number. 2. Once in place, move the boot in the direction of the battery compartment.Gently click the audio boot onto the hearing instrument. Disconnecting audio boots 3. Press and hold the button on the front side of the audio boot. 4. Gently remove the audio boot from the hearing instrument. 25 400344000-GB-14.11-Rev.A.indd 25 10-12-2014 11:22:32 i Care and maintenance Please follow the following instructions to prolong the durability of your hearing instruments: 1. Keep your hearing instrument clean and dry. Wipe the case with a soft cloth or tissue after use to remove grease or moisture. Do not use water or solvents, as these can damage the hearing instrument(s). 2. Never immerse hearing instruments in water or other liquids, as liquids may cause permanent damage to the hearing instruments. 3. Avoid rough handling of hearing instruments or dropping them on hard surfaces or floors. 4. Do not leave hearing instruments in or near direct heat or sunlight, such as in a hot, parked car, as excessive heat can cause damage or deform the casing. 5. Do not wear your instrument while showering, swimming, in heavy rain or in a moist atmosphere such as a steam bath or sauna.If your instrument does get wet, or if it has been exposed to high humidity or perspiration, it should be left to dry out overnight with the battery out and the battery compartment open. It is also a good idea to put the instrument and battery in a sealed container together with a drying agent (desiccator) overnight. Do not use the instrument until it is completely dry. Consult your hearing care professional as to which drying agent to use. 6. Remove your hearing instrument when applying such things as cosmetics, perfume, aftershave, hair spray, and suntan lotion. These might get into the instrument and cause damage. 26 400344000-GB-14.11-Rev.A.indd 26 10-12-2014 11:22:32 i Daily maintenance It is important to keep your hearing instrument clean and dry. On a daily basis, clean the hearing instruments using a soft cloth or tissue. 27 400344000-GB-14.11-Rev.A.indd 27 10-12-2014 11:22:32 The receiver tube The receiver tube contains the wiring to the receiver which delivers the sound to the ear canal. It is important that the receiver tube and the receiver dome/RIE mold fits correctly in your ear. If the receiver tube or the receiver dome/RIE mould irritates your ear in any way and prevents you from wearing your hearing instrument, please contact your hearing care professional. You should never attempt to modify the shape of the receiver tube yourself. The receiver tube and the receiver dome/RIE mould should be cleaned regularly. Please see instructions in the next section. i Cleaning the receiver tubes and domes The receiver tube and the receiver dome should be cleaned regularly. Use a damp cloth to clean the receiver tube and receiver dome on the outside. Do not use water when you are cleaning the receiver tubes or the receiver domes. This process is also used to clean the UP receiver mould. Please see instruction on page 30 or 31 for how to change the wax guard filter. i Cleaning RIE or moulds 1. Separate the mould from the receiver tube. 2. Clean the RIE mould using a mild soap, and rinse with lukewarm water. 3. After cleaning, dry RIE moulds thoroughly and remove any residual water and debris from the tubing utilising an air bulb and wire loop. 28 400344000-GB-14.11-Rev.A.indd 28 10-12-2014 11:22:32 Changing wax guard for receiver tube For changing Cerustop (white) wax filters, the following steps are needed: 1. To remove the old wax guard, insert the removal side of the wax guard tool into the used wax guard so that the shaft of the tool is touching the rim of the wax guard. Slowly pull the wax guard straight out. 2. To insert the new wax guard, gently press the replacement side of the wax guard tool straight into the hole of the sound outlet until the outer ring lies flush with the outside of the receiver. Pull the tool straight out -the new wax guard will remain in place. 29 400344000-GB-14.11-Rev.A.indd 29 10-12-2014 11:22:32 How to apply domes It is recommended that your hearing care professional change domes, as incorrect dome replacement could result in injury. ReSound standard domes 1. Push the new dome over the receiver. 2. Make sure that the new dome is properly and securely mounted. ReSound tulip domes Tulip domes are mounted in a similar manner to standard domes, but a few extra steps are required. Tulip domes consist of two “petals”. It is important to note that the largest petal is the outermost petal. To ensure this: 1. Push the largest petal away from the receiver tube using a finger. This bends the petal forward. 2. Then push the largest “petal” back, and it will be placed on top of the smaller petal. 30 400344000-GB-14.11-Rev.A.indd 30 10-12-2014 11:22:33 Using ReSound hearing instruments with smart phone apps Intended use of smart phone apps: GN ReSound smart phone apps are intended to be used with GN ReSound wireless hearing aids. GN ReSound smart phone apps send and receive signals from the GN ReSound wireless hearing aids via smart phones for which the apps have been developed. Use with smart phone apps: • Notifications of app updates should not be disabled, and it is recommended that the user installs all updates to ensure that the app will function correctly and will be kept up to date. • The app must only be used with GN ReSound devices for which it is intended, and GN ReSound take no responsibility if the app is used with other devices. • If you would like a printed version of the user guide for a smart phone app please consult customer support or our website to obtain a printed user guide. 31 400344000-GB-14.11-Rev.A.indd 31 10-12-2014 11:22:33 i General precautions 1. 2. 3. 4. 5. When wireless function is activated, the device uses low-powered digitally coded transmissions in order to communicate with other wireless devices. Although unlikely, nearby electronic devices may be affected. In that case, move the hearing instrument away from the affected electronic device. When using wireless functionality and the devices are affected by electromagnetic interference, move away from the source. Use only original GN ReSound consumables e.g. tubes and domes. Never attempt to modify the shape of the hearing instrument, ear-moulds, or tubing yourself. Do only connect ReSound hearing instruments to ReSound accessories intended and qualified to be used with ReSound hearing instruments. i General warnings 1. Special care should be exercised in selecting and fitting a hearing instrument(s) who’s maximum sound pressure level exceeds 132 dB SPL (with an IEC 60711:1981 occluded ear simulator), because there may be a risk of impairing the remaining hearing of the hearing instrument user 2. Consult a hearing care professional if you discover a foreign object in your ear canal, if you experience skin irritation, or if excessive ear wax accumulates with the use of the hearing instrument. 3. Different types of radiation, from e.g. NMR, MRI, or CT scanners, may damage hearing instruments. It is recommended not to wear hearing instruments during these or other similar procedures. Other types of radiation, such as burglar alarms, room surveillance systems, radio equipment, mobile telephones, contain less energy and will not damage hearing instruments. However, they have the potential to momentarily affect the sound quality or temporarily create strange sounds from hearing instruments. 4. Do not wear hearing instruments in mines, oil fields, or other explosive areas unless those areas are certified for hearing instrument use. 32 400344000-GB-14.11-Rev.A.indd 32 10-12-2014 11:22:33 5. Do not allow others to use your hearing instruments. This may cause damage to the hearing instruments or to the hearing of the other individual. 6. Instrument usage by children or mentally challenged persons should be supervised at all times to ensure their safety.The hearing instrument contains small parts that could be swallowed by children. Please be mindful not to leave children unsupervised with this hearing instrument. 7. Hearing instruments should be used only as prescribed by your hearing care professional. Incorrect use may result in hearing loss. 7. External devices connected to the electrical input must be safe according to the requirements of IEC 60601-1-1, IEC 60065, or IEC 60950-1, as appropriate (wired connection, f.ex. HI-PRO), SpeedLink). 8. If device is broken, do not use. 9. Be careful when boarding flights, to remember to deactivate the wireless functionality. Turn off your wireless functionality by using the flight mode in areas where radio frequency emission is prohibited. Note: * ReSound wireless devices operate in the frequency range of 2.4 GHz - 2.48 GHz. * ReSound wireless devices include a RF transmitter that operates in the range of 2.4 GHz - 2.48 GHz. * For use of wireless functionality only use ReSound Unite accessories. For further guidance regarding e.g. pairing, please refer to the user guide of the relevant ReSound Unite accessory. 33 400344000-GB-14.11-Rev.A.indd 33 10-12-2014 11:22:34 Tinnitus Sound Generator (TSG) module Intended use for the TSG module Your ReSound hearing instruments may also include the Tinnitus Sound Generator function, a tool for generating sounds to be used in tinnitus management programmes to relieve suffering from tinnitus. The Tinnitus Sound Generator can generate sounds adjusted to the specific therapeutic needs and your personal preference as determined by your doctor, audiologist, or hearing care professional. Depending on the selected hearing instrument program and the environment you are in, you will sometimes hear the therapeutic sound resembling a continuous or fluctuating whistling. User instructions for the TSG module Description of the device The Tinnitus Sound Generator (TSG) Module is a software tool that generates sounds to be used in tinnitus management programmes to relieve suffering from tinnitus. Explanation of how the device functions The TSG module is a frequency and amplitude shaped white-noise generator. Noise signal level and frequency characteristics can be adjusted to the specific therapeutic needs as determined by your doctor, audiologist or hearing healthcare professional. Your doctor, audiologist or hearing healthcare professional can modulate the generated noise with the purpose of making it more pleasant. The noise can then resemble, for example, crushing waves on a shore. Modulation level and speed can also be configured to your likes and needs. If your tinnitus troubles you only in quiet environments, your doctor, audiologist or hearing healthcare pro34 400344000-GB-14.11-Rev.A.indd 34 10-12-2014 11:22:34 fessional can set the TSG Module so that it becomes audible exclusively in such surroundings. The overall sound level can be adjusted via an optional volume control. Your doctor, audiologist or hearing healthcare professional will review with you the need for having such a control. TSG volume control The sound generator is set to a specific loudness level by the hearing healthcare professional. When switching the sound generator on, the volume will have this optimal setting. Therefore, it might not be necessary to control the volume (loudness) manually. However, the volume control provides the ability to adjust the volume, or amount of stimulus, to the liking of the user. 35 400344000-GB-14.11-Rev.A.indd 35 10-12-2014 11:22:34 The scientific concepts that form the basis for the device The TSG Module provides sound enrichment with the aim of surrounding the tinnitus sound with a neutral sound which is easily ignored. Sound enrichment is an important component of most approaches to tinnitus management, such as Tinnitus Retraining Therapy (TRT). To assist habituation to tinnitus, this needs to be audible. The ideal level of the TSG module, therefore, should be set so that it starts to blend with the tinnitus, and so that you can hear both your tinnitus as well as the sound used. In a majority of instances, the TSG module can also be set to mask the tinnitus sound, so to provide temporary relief by introducing a more pleasant and controllable sound source. Technical Specifications Audio signal technology Digital Available sounds White noise signal which can be shaped with the following configurations: The white noise signal can be modulated in amplitude with an attenuation depth of up to 14dB. High-pass filter Low-pass filter 500 Hz 750 Hz 2000 Hz 3000 Hz 1000 Hz 4000 Hz 1500 Hz 5000 Hz 2000 Hz 6000 Hz 36 400344000-GB-14.11-Rev.A.indd 36 10-12-2014 11:22:34 i TSG warnings • Sound generators can be dangerous if improperly used. • Sound generators should be used only as advised by your doctor, audiologist, or hearing healthcare professional. • Sound generators are not toys and should be kept out of reach of anyone who might cause themselves injury (especially children and pets). i TSG precautions • Should the user develop any side effects from using the sound generator, such as dizziness, nausea, headaches, perceived decrease in auditory function or increase in tinnitus perception, the user should discontinue use of the sound generator and seek medical evaluation. • Children and physically or mentally challenged users will require guardian supervision while wearing the TSG hearing instrument. • The volume control is an optional feature in the TSG module used for adjusting the sound generator output level. To prevent unintended usage by pediatric or physically or mentally challenged users, the volume control must, if enabled, be configured to only provide a decrease of the sound generator output level. 37 400344000-GB-14.11-Rev.A.indd 37 10-12-2014 11:22:34 i TSG warning to hearing healthcare professionals A hearing healthcare professional should advise a prospective sound generator user to consult promptly with a licensed physician (preferably an ear specialist) before getting a sound generator if the hearing healthcare professional determines through inquiry, actual observation, or review of any other available information concerning the prospective user that the prospective user has any of the following conditions: (i) Visible congenital or traumatic deformity of the ear. (ii) History of active drainage from the ear within the previous 90 days. (IIi) History of sudden or rapidly progressive hearing loss within the previous 90 days. (iv) Acute or chronic dizziness. (v) Unilateral hearing loss of sudden or recent onset within the previous 90 days. (vi) Audiometric air-bone gap equal to or greater than 15dB at 500 hertz (Hz), 1000 Hz, and 2000 Hz. (vii) Visible evidence of significant cerumen accumulation or a foreign body in the ear canal. (viii) Pain or discomfort in the ear. CAUTION: The maximum output of the sound generator falls into the range that can cause hearing loss according to OSHA regulations. The user should not use the sound generator for more than eight (8) hours a day when this is set below 90dB SPL. Above that level, the device should not be used for more than two (2) hours per day. In no case should the sound generator be worn at uncomfortable levels. 38 400344000-GB-14.11-Rev.A.indd 38 10-12-2014 11:22:34 i Battery warning information Batteries, although very small, contain dangerous substances, and should be disposed of carefully. This is for the safety of you and the environment. Please note: 1. Do not attempt to recharge batteries (Zinc Air) which are not specifically designated as rechargeable because they may leak or explode. 2. DO NOT attempt to dispose of batteries by burning them. Used batteries are harmful to the environment. Please dispose of them according to local regulations or return them to your hearing care practitioner. 3. DO NOT place batteries in your mouth. Consult a physician immediately if a battery has been swallowed, as they can be harmful to your health. 4. Keep batteries away from pets, children and mentallly challenged persons. 5. Remove the batteries to prevent leakage when the hearing instruments are not in use for an extended period of time. i Hearing instrument expectations A hearing instrument will not restore normal hearing and will not prevent or improve a hearing impairment resulting from organic conditions. Consistent use of the hearing instrument is recommended. In most cases, infrequent use does not permit you to attain full benefit from it. The use of a hearing instrument is only part of hearing rehabilitation and may need to be supplemented by auditory training and instructions in lip-reading. 39 400344000-GB-14.11-Rev.A.indd 39 10-12-2014 11:22:34 i Warning to hearing aid dispensers (US Only) A hearing aid dispenser should advise a prospective hearing aid user to consult promptly with a licensed physician (preferably an ear specialist) before dispensing a hearing aid if the hearing aid dispenser determines through inquiry, actual observation, or review of any other available information concerning the prospective user, that the prospective user has any of the following conditions: (i) Visible congenital or traumatic deformity of the ear. (ii) History of active drainage from the ear within the previous 90 days. (iii) History of sudden or rapidly progressive hearing loss within the previous 90 days. (iv) Acute or chronic dizziness. (v) Unilateral hearing loss of sudden or recent onset within the previous 90 days. (vi) Audiometric air-bone gap equal to or greater than 15 decibels at 500 hertz (Hz), 1,000 Hz, and 2,000 Hz. (vii) Visible evidence of significant cerumen accumulation or a foreign body in the ear canal. (viii) Pain or discomfort in the ear. Important notice for prospective hearing aid users (US Only) Good health practice requires that a person with a hearing loss have a medical evaluation by a licensed physician (preferably a physician who specializes in diseases of the ear) before purchasing a hearing aid. Licensed physicians who specialize in diseases of the ear are often referred to as otolaryngologists, otologists or otorhinolaryngologists. The purpose of medical evaluation is to assure that all medically treatable conditions that may affect hearing are identified and treated before the hearing aid is purchased. Following the medical evaluation, the physician will give you a written statement that states that your hearing loss has been medically evaluated and that you may be considered a candidate for a hearing aid. The physician will refer you to an audiologist or a hearing aid dispenser, as appropriate, for a hearing aid evalu40 400344000-GB-14.11-Rev.A.indd 40 10-12-2014 11:22:34 ation. The audiologist or hearing aid dispenser will conduct a hearing aid evaluation to assess your ability to hear with and without a hearing aid. The hearing aid evaluation will enable the audiologist or dispenser to select and fit a hearing aid to your individual needs. If you have reservations about your ability to adapt to amplification, you should inquire about the availability of a trial-rental or purchase-option program. Many hearing aid dispensers now offer programs that permit you to wear a hearing aid for a period of time for a nominal fee after which you may decide if you want to purchase the hearing aid. Federal law restricts the sale of hearing aids to those individuals who have obtained a medical evaluation from a licensed physician. Federal law permits a fully informed adult to sign a waiver statement declining the medical evaluation for religious or personal beliefs that preclude consultation with a physician. The exercise of such a waiver is not in your best health interest and its use is strongly discouraged. Children with hearing loss (US Only) In addition to seeing a physician for a medical evaluation, a child with a hearing loss should be directed to an audiologist for evaluation and rehabilitation since hearing loss may cause problems in language development and the educational and social growth of a child. An audiologist is qualified by training and experience to assist in the evaluation and rehabilitation of a child with a hearing loss. 41 400344000-GB-14.11-Rev.A.indd 41 10-12-2014 11:22:34 Troubleshooting Guide SYMPTOM CAUSE No sound Not turned on Dead battery Battery door will not close Blocked RIE mould or tube Blocked wax filter Incorrect RIE mould placement Blocked RIE mould or dome Change in hearing sensitivity Excessive ear wax Volume set too low Not loud enough 42 400344000-GB-14.11-Rev.A.indd 42 10-12-2014 11:22:34 POSSIBLE REMEDY Turn on by closing the battery door Replace battery Insert battery properly Clean RIE mould or tube Replace wax filter or consult your hearing care professional Reinsert RIE mould Clean RIE mould, replace dome, replace filter Consult your hearing care professional Consult your hearing care professional Consult your hearing care professional 43 400344000-GB-14.11-Rev.A.indd 43 10-12-2014 11:22:34 Troubleshooting Guide SYMPTOM CAUSE Excessive whistling / feedback Incorrect RIE mould placement Incorrect dome placement Excessive ear wax Feedback control may need adjustment RIE mould tubing worn or damaged Hearing instrument settings not optimal Weak battery Improper RIE mould or dome fit Hearing instrument damaged Hearing instrument settings not optimal Possible Root Cause - Device is in flight mode Sound distorted / not clear Wireless does not work 44 400344000-GB-14.11-Rev.A.indd 44 10-12-2014 11:22:34 POSSIBLE REMEDY Re-insert RIE mould carefully Re-insert dome Consult your hearing care professional Consult your hearing care professional Consult your hearing care professional Consult your hearing care professional Replace battery Consult your hearing care professional Consult your hearing care professional Consult your hearing care professional Open and close the battery compartment once. Wireless will reactivate 10 seconds later. (If Root Cause is device in flight mode) If there are any other problems not mentioned in this guide, please contact your hearing care professional. 400344000-GB-14.11-Rev.A.indd 45 45 10-12-2014 11:22:34 Technical data MAXIMUM OUTPUT (OSPL 90) RIE - LP receiver HFA 31 dB Full-on gain (50 dB SPL Input) Max HFA Maximum output (90 dB SPL input) Max HFA 52 43 113 108 dB dB dB SPL dB SPL 500 Hz 800 Hz 1600 Hz 0.3 0.5 0.7 Telecoil sensitivity (SPLIV @ 31,6 mA/m) 90 dB SPL Equivalent input noise (w/o noise reduction) 23 dB SPL Total harmonic distortion Frequency range (DIN 45605) Current drain (in test mode) 100– Hz 7060 1.3 mA Frequency (Hz) FULL-ON AND REFERENCE TEST GAIN 2cc Coupler Full-on gain 50 dB SPL input Gain (dB) Reference test gain (60 dB SPL input) Output (dB SPL) 2cc Coupler Models: LS962-DRW, LS762-DRW, LS562-DRW LS961-DRW, LS761-DRW, LS561-DRW Reference test gain 60 dB SPL input Note: Telecoil sensitivity only applicable for 62 RIE models Frequency (Hz) Data in accordance with ANSI S3.22–2009 and IEC 60118-7; Supply Voltage 1.3 V, 2cc coupler 46 400344000-GB-14.11-Rev.A.indd 46 10-12-2014 11:22:34 MAXIMUM OUTPUT (OSPL 90) RIE—MP receiver HFA 37 dB Full-on gain (50 dB SPL Input) Max HFA Maximum output (90 dB SPL input) Max HFA 58 51 116 114 dB dB dB SPL dB SPL 500 Hz 800 Hz 1600 Hz 0.5 0.6 1.2 Telecoil sensitivity (SPLIV @ 31.6 mA/m) 96 dB SPL Equivalent input noise (w/o noise reduction) 23 dB SPL Total harmonic distortion Frequency range (DIN 45605) Current drain (in test mode) 100– Hz 7000 1.3 Note: Telecoil sensitivity only applicable for 62 RIE models mA Frequency (Hz) FULL-ON AND REFERENCE TEST GAIN 2cc Coupler Full-on gain 50 dB SPL input Gain (dB) Reference test gain (60 dB SPL input) Output (dB SPL) 2cc Coupler Models: LS762-DRW, LS762-DRW, LS562-DRW LS961-DRW, LS761-DRW, LS561-DRW Reference test gain 60 dB SPL input Frequency (Hz) Data in accordance with ANSI S3.22–2009 and IEC 60118-7; Supply Voltage 1.3 V, 2cc coupler 47 400344000-GB-14.11-Rev.A.indd 47 10-12-2014 11:22:35 MAXIMUM OUTPUT (OSPL 90) RIE—HP receiver HFA 42 dB Full-on gain (50 dB SPL Input) Max HFA Maximum output (90 dB SPL input) Max HFA 65 56 122 118 dB dB dB SPL dB SPL 500 Hz 800 Hz 1600 Hz 0.6 1.2 0.7 Telecoil sensitivity (SPLIV @ 31.6 mA/m) 101 dB SPL Equivalent input noise (w/o noise reduction) 23 dB SPL Total harmonic distortion Frequency range (DIN 45605) Current drain (in test mode) 100– Hz 6030 1.3 mA Frequency (Hz) FULL-ON AND REFERENCE TEST GAIN 2cc Coupler Full-on gain 50 dB SPL input Gain (dB) Reference test gain (60 dB SPL input) Output (dB SPL) 2cc Coupler Models: LS962-DRW, LS762-DRW, LS562-DRW LS961-DRW, LS761-DRW, LS561-DRW Reference test gain 60 dB SPL input Note: Telecoil sensitivity only applicable for 62 RIE models Frequency (Hz) Data in accordance with ANSI S3.22–2009 and IEC 60118-7; Supply Voltage 1.3 V, 2cc coupler 48 400344000-GB-14.11-Rev.A.indd 48 10-12-2014 11:22:35 MAXIMUM OUTPUT (OSPL 90) RIE—UP receiver HFA 47 dB Full-on gain (50 dB SPL Input) Max HFA Maximum output (90 dB SPL input) Max HFA 75 64 129 124 dB dB dB SPL dB SPL 500 Hz 800 Hz 1600 Hz 1.3 2.1 0.1 Telecoil sensitivity (SPLIV @ 31.6 mA/m) 107 dB SPL Equivalent input noise (w/o noise reduction) 23 dB SPL Total harmonic distortion Frequency range (DIN 45605) Current drain (in test mode) 100– Hz 4910 1.2 Note: Telecoil sensitivity only applicable for 62 RIE models mA Frequency (Hz) FULL-ON AND REFERENCE TEST GAIN 2cc Coupler Full-on gain 50 dB SPL input Gain (dB) Reference test gain (60 dB SPL input) Output (dB SPL) 2cc Coupler Models: LS962-DRW, LS762-DRW, LS562-DRW LS961-DRW, LS761-DRW, LS561-DRW Reference test gain 60 dB SPL input Frequency (Hz) Data in accordance with ANSI S3.22–2009 and IEC 60118-7; Supply Voltage 1.3 V, 2cc coupler 49 400344000-GB-14.11-Rev.A.indd 49 10-12-2014 11:22:36 Warranty and repairs ReSound provides a warranty on hearing instruments in the event of defects in workmanship or materials, as described in applicable warranty documentation. In its service policy, ReSound pledges to secure functionality at least equivalent to the original hearing instrument. As a signatory to the United Nations Global Compact initiative, ReSound is committed to doing this in line with environment-friendly best practices. Hearing instruments therefore, at ReSound’s discretion, may be replaced by new products or products manufactured from new or serviceable used parts, or repaired using new or refurbished replacement parts. The warranty period of hearing instruments is designated on your warranty card, which is provided by your hearing care professional. For hearing instruments that require service, please contact your hearing care professional for assistance. ReSound hearing instruments that malfunction must be repaired by a qualified technician. Do not attempt to open the case of hearing instruments, as this will invalidate the warranty. Temperature test, transport and storage information GN ReSound Hearing Instruments are subjected to various tests in temperature and damp heating cycling between -25 °C and +70 °C according to internal and industry standards. During transport or storage, the temperature should not exceed the limit values of -20 °C to 60 °C and relative humidity of 90% RH, non condensing (for limited time). The air pressure between 500 and 1100 hPa is appropriate. 50 400344000-GB-14.11-Rev.A.indd 50 10-12-2014 11:22:36 Be aware of information marked with the warning symbol WARNING points out a situation that could lead to serious injuries, CAUTION indicates a situation that could lead to minor and moderate injuries Advice and tips on how to handle your hearing instrument better. Equipment includes RF transmitter ReSound LiNX2 is compatible with iPhone 6, iPhone 6 Plus, iPhone 5s, iPhone 5c, iPhone 5, iPad Air 2, iPad Air, iPad (4th generation), iPad mini 3, iPad mini 2, iPad mini with Retina display, iPad mini and iPod touch (5th generation) using iOS 7.X or later. Apple, the Apple logo, iPhone, iPad and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. “Made for iPhone” means that an electronic accessory has been designed to connect specifically to iPhone and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that the use of this accessory with iPhone may affect wireless performance. Please ask your local hearing care professional concerning disposal of your hearing instrument 51 400344000-GB-14.11-Rev.A.indd 51 10-12-2014 11:22:37 400344000-GB-14.11-Rev.A Worldwide Headquarters ReSound A/S Lautrupbjerg 7 DK-2750 Ballerup, Denmark Tel.: +45 45 75 11 11 Fax: +45 45 75 11 19 www.resound.com CVR no. 55082715 United Kingdom GN ReSound Ltd. Kirtlington Business Centre Portway Kirtlington Oxon OX5 3JA Tel.: +44 1869 352 800 Fax: +44 1869 343 466 www.gnresound.co.uk Australia GN ReSound Pty. Ltd. Unit R1 Regents Park Estate 391 Park Road Regents Park NSW 2143 Tel.: (free) 1800 658 955 Fax: +61 2 9743 7472 www.gnresound.com.au New Zealand GN ReSound (NZ) Ltd. 12 Parkway Drive Mairangi Bay Auckland Tel.: (free) 0800 900 126 Fax: (free) 0800 007 695 www.gnresound.co.nz Any issues relating to the EU Medical Device Directive 93/42/EEC, or Council Directive 1999/5/EC on Radio Equipment and Telec ommunications terminal equipment should be directed to ReSound A/S 400344000-GB-14.11-Rev.A.indd 52 10-12-2014 11:22:37
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Instance ID : uuid:60f6dc4e-ef90-4ba9-8a54-443f701d69b0 Original Document ID : adobe:docid:indd:88e0b211-62ab-11e0-8b29-d7f6184693f4 Document ID : xmp.id:8b583849-cfb7-db44-94d8-f44983b96ca5 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:9621e5c7-6999-3642-aeaf-f08cb7fd488a Derived From Document ID : xmp.did:f9aa6591-a5d1-034c-889b-a37e04ffec03 Derived From Original Document ID: adobe:docid:indd:88e0b211-62ab-11e0-8b29-d7f6184693f4 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2014 (Windows) History Changed : / History When : 2014:12:10 11:22:23+01:00 Create Date : 2014:12:10 11:22:23+01:00 Modify Date : 2014:12:16 11:26:19+01:00 Metadata Date : 2014:12:16 11:26:19+01:00 Creator Tool : Adobe InDesign CC 2014 (Windows) Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 52 Creator : Adobe InDesign CC 2014 (Windows)EXIF Metadata provided by EXIF.tools