GN Hearing A S VE312 Wireless hearing instrument User Manual UserMan Lima

GN Hearing A/S Wireless hearing instrument UserMan Lima

Contents

UserMan Lima

Instructions for useDigital Receiver In-the-Ear (RIE) hearing
2 3This device operates in the frequency range of 2.4 GHz - 2.48 GHz. This device includes an RF transmitter that operates in the range of 2.4 GHz - 2.48 GHz.Statement: This device complies with Part 15 of the FCC Rules and IC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules  and ICES-003  of the  IC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy  and,  if  not  installed  and  used  in  accordance  with  the instructions, may cause harmful interference to  radio  communications.  However,  there  is  no  guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from the one in which the receiver is con-nected. • Consult the dealer or an experienced radio/TV technician for help. Changes or modifications can void the user´s authority to operate the equipment Intended use: Generic air-conduction hearing instruments are wearable sound-amplifying devices intended to compen-sate for impaired hearing. The fundamental operating principle of hearing instruments is to receive, amplify, and transfer sound to the ear drum of a hearing impaired person. List of countries: Products without wireless functionality are intended for worldwide sales. Products with wireless functionality are intended for sale in countries within European Economic Area as well as Switzerland. The products are in compliance with the following regulatory requirements: • In EU: the device conforms to the Essential Requirements according to Annex  I of Council Directive 93/42/EEC for medical devices (MDD) and essential requirements and other relevant provisions of Direc-Type Designation: SY312, FCC ID: X26SY312; IC: 6941C-SY312Type Designation: SY312e, FCC ID: X26SY312e; IC: 6941C-SY312eType Designation: MRIE, FCC ID: X26MRIE; IC: 6941C-MRIEType Designation: VE312, FCC ID: X26VE312; IC: 6941C-VE312, LimaPlease see page 4 for list of models referring to all types.
4 5Digital  Receiver  In-the-Ear  (RIE)  wireless  hearing  Instruments  models  (type  MRIE)  are  available  in  the   following  variants:  TRU1764DW,  TRU1764DPW,  TRU964DW, TRU964DPW,  TRU664DW,  TRU664DPW, PSE1764-DRPW,  PSE1764-DRW,  PSE1764-DRSW,  PSE964-DRPW,  PSE964-DRW,  PSE964-DRSW, PSE664-DRPW, PSE664-DRW, and PSE664-DRSWDigital  Receiver  In-the-Ear  (RIE)  wireless  hearing  instrument  models  (type  VE312)  are  available  in  the   following variants: FI1763-DRW, FI1763-DRSW, FI1763-DRPW, FI1763-DRUW, FI963-DRW, FI963-DRSW, FI963-DRPW, FI963-DRUWA new Beltone hearing instrumentCongratulations on your choice of a Beltone hearing instrument!This is an important step towards clearer hearing and better understanding. We have used all of our experience with hearing instruments to help you communicate, lead an enjoyable social life and listen to the world around you.Your hearing instrument is a very advanced device. Your hearing care practitioner has tuned it to your individual needs. With a little devotion and patience you will become familiar with it.This booklet is a short guide to assist you in getting acquainted with your hearing instrument. Read it carefully and use it as a guideline. We wish you happiness and pleasant listening with your new instrument.BeltoneThis booklet & your instrumentIn this booklet you will find instructions for inserting and controlling your new hearing instrument. You will find explanations on controlling your instrument, on daily handling and on its use. Furthermore, you can read what to do if things do not live up to your expectations. We will give a few practical steps towards better hearing.Digital  Receiver  In-the-Ear  (RIE)  wireless  hearing  Instruments  models  (type  SY312)  are  available  in   following  variants:  TRU1763DW,  TRU1763DPW, TRU963DW,  TRU963DPW, TRU663DW,  TRU663DPW, TRU363DW, TRU363DPW Digital  Receiver  In-the-Ear  (RIE)  wireless  hearing  Instruments  models  (type  SY312e)  are  available  in   following  variants:  PSE1763-DRPW,  PSE1763-DRW,  PSE1763-DRSW,  PSE963-DRPW,  PSE963-DRW, PSE963-DRSW, PSE663-DRPW, PSE663-DRW, and PSE663-DRSW• In US: FCC CFR 47 Part 15, subpart C• In Canada these hearing instruments are certified under the rules of IC.• Other identified applicable international regulatory requirements in countries outside EU and US. Please     refer to local country requirements for these areas.•   Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.•   L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage,      et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, meme si le brouillage est     susceptible d’en compromettre le fonctionnement.•   Japanese Radio Law and Japanese Telecommunications Business Law Compliance.     This device is granted pursuant to the Japanese Radio Law (            ) and the Japanese     Telecommunications Business Law (                        ) This device should not be modified (otherwise the     granted designation number will become invalid)
6 7ContentsWarning to hearing care professional  7Your Hearing Instrument  8On/Off function  10Delayed Activation  10Changing batteries  11Inserting and removing the device  13Program and Multi-function buttons  16Telephone use  20Auto-phone  20T-program  22Audio Input  24Listen to radio or TV  25Flight mode  25Daily maintenance  27The receiver tube  28Cleaning the receiver tube and the receiver domes  28Cleaning the RIE mold  29The receiver domes  30Wax guard filter  30Tinnitus Breaker Pro   31Prescription Use for Sound Generator Users   32CAUTION - Tinnitus Sound Generator   32General precautions  34General warnings  35Eight steps towards better hearing  36Troubleshooting guide  40Technical specifications  44International warranty, service and repairs  47Your selected model  48Warning to hearing care professional iA hearing care professional should advise a prospective user to consult promptly with a licensed physi-cian (preferably an ear specialist) before setting the instrument if the hearing care professional determines through inquiry, actual observation, or review of any other avail able information concerning the prospective user that the prospective user has any of the following conditions:(i)  visible congenital or traumatic deformity of the ear;(ii)  history of active drainage from the ear within the previous 90 days;(iii)   history of sudden or rapidly progressive hearing loss within the previous 90 days;(iv)   acute or chronic dizziness;(v)   unilateral hearing loss of sudden or recent onset within the previous 90 days;(vi)   audiometric air-bone gap equal to or greater than 15dB at 500 Hz (hertz), 1000 Hz, and 2000 Hz;(vii)   visible evidence of significant cerumen accumulation or a foreign body in the ear canal;(viii)
8 9Your Hearing Instrument(Please see page 48-52 for your selected model) 1.  Receiver tube 2a.  Receiver Mini Dome 2b.  Receiver “Tulip” Dome2c.  Receiver Power Dome 2d.  RIE mold3.  Sports lock4.  Battery compartment5.  Receiver6.  Push button64DW7.  Multi-function button8.  Model, and serial number9.  Left/right indicator 63DW62DAvailable Receiver Tube Models2d2c2b464152a352a14715982aS Receiver NP Receiver HP Receiver
Your Hearing Instrument(Please see page 48-52 for your selected model) 1.  Receiver tube 2a.  Receiver Mini Dome 2b.  Receiver “Tulip” Dome2c.  Receiver Power Dome 2d.  RIE mold3.  Sports lock4.  Battery compartment5.  Receiver6.  Push buttonFirst device2d2c2b32a156410 11
12 13On/Off functionYour hearing aid is equipped with an on/off switch inte-grated into the battery compartment. When the battery compartment is fully closed, the in-strument is turn-ed on. To turn the instrument off, grasp the battery compartment door with your fingernail and gently pull downwards. The power will switch off at the point where you can feel a small click. Whenever you are not wearing the instrument,  remember to turn it off to reduce battery consumption.Delayed ActivationYour hearing care professional may have activated the Delayed Activation function in your hearing instru-ment. The Delayed Activation delays the switch-on time 10 seconds after closing the battery compartment. This is indicated by beeps at one second intervals after closing the battery compartment, which means that you could hear 10 beeps before the hearing aid is activated. If you wish, it can be deactivated by your hearing care professional.OnOffChanging batteries(Please see “Your selected model” for the battery size of your hearing instrument)Low battery indicationYour hearing care professional can set your hearing instrument to give an acous-tical indication when the  battery is  reaching its end of life.  The  hearing instru-ment will reduce amplification and emit a melody if battery power gets too low. This signal will recur every five minutes until the hearing instrument automatically switches off. It is recommended that you keep spare batteries on hand. Low battery indicator (when paired with Direct Line accessories)Active usage of Beltone Direct Line accessories (for example: Remote Control, TV Link, and Phone Link) requires more battery power from the hearing instrument than when these are working on their own. When the battery in the hearing instrument has depleted to a level at which use of the TV Link, and Phone Link or Personal Audio Link cannot be supported, the hearing instrument will play two sets of descending tones. At some point the battery level will not support the remote control either and you will once again hear the descending tones. The hearing instrument will continue to work as usual. Once a new battery is inserted, full operation of the wireless accessories will resume.Replacing the batteryOpen the battery compartment completely by using your fingernail.  After removing the old battery (if pre-sent), insert the new one with the positive (+) side in the correct position. Please make sure that you have the correct size battery for your hearing instrument. Gently close the battery door. Do not force it closed. If door does not close easily, remove battery and try again.
14 15Inserting and removing the deviceInserting custom RIE and UP molds:1.  Hold  the  RIE  mold  between  your  thumb  and  index  finger  and  position  its sound outlet in your ear canal.2.  Slide the RIE mold all the way into your ear with a gentle, twisting movement.3.  Move the RIE mold up and down and gently press to ensure it is positioned correctly in the ear. Opening and closing your mouth can ease insertion.4.  Make sure the hearing instrument is seated behind the ear.Battery warning information iBatteries contain dangerous substances and should be disposed of carefully in the interest of your safety and for the environment.• Keep batteries away from pets, children and mentally challenged persons.• Do not place batteries in your mouth. Consult a physician immediately if a battery has been swallowed, as they can be harmful to your health..• DO NOT burn the batteries, as they could explode.• DO NOT attempt to recharge batteries (Zinc Air) which are not specifically designated rechargeable as they may leak or explode.• Replace spent batteries and do not leave them in the instrument for a prolonged period to prevent leak-age.• Used batteries are harmful to the environment. Please dispose of them according to local regulations or return them to your hearing care practitioner.• Remove the batteries to prevent leakage when the hearing instruments are not in use for an extended period of time. i For best performance, always use new Zinc-Air batteries that have a minimum remaining shelf life of 1 year.i Whenever the hearing instruments are not in use, remember to turn them off to avoid unnecessary battery consumption.
16 17Inserting receiver domes:1.  Hang the instrument over the top of the ear.2.  Grasp the receiver tube where it bends and place the receiver dome in your ear canal. The receiver dome should be placed far enough into the ear so that the receiver tube lies flush with your head.3.  If the hearing care professional has provided you with a sport lock on the receiver tube, make sure to position it into the indentation above the earlobe.4.  When the receiver dome is placed appropriately, you should not see the receiver tube sticking out when you look directly into a mirror.5.  If the device whistles, the most likely reason is that the receiver dome is not placed correctly in the ear canal. Other reasons can be build-up of earwax in the ear canal. It is also possible that the instrument settings are not optimal. To help you solve these issues it is recommended to contact your hearing care professional.Removing:1.  Grasp the receiver tube where it bends, or pull-out cord when using an RIE or UP mold, and pull the receiver dome out of your ear canal.i  Note: You should never attempt to bend or modify the shape of the hearing instrument, RIE molds, or receiver tubing yourself.2.  Lift the hearing instrument of your ear.
18 19Your instrument has a fully automatic volume control. Therefore, it should not be necessary to control the volume manually. However, in addition to controlling listening programs, the multi-function button (64DW only) provides you with the ability to adjust the amplification to your liking.The multi-function button is designed to change the volume or listening programs of the hearing instrument, based on different ways it is pressed. If necessary, your hearing care practitioner can change these settings and fill in the following table to indicate the new settings:Program button (63DW) Multi-function button (64DW)Multi-function button action Default setting New settingShort press up Increases volumeShort press down Decreases volumeLong press up (3 seconds)  Changes programsLong press down (3 seconds) Activates streaming*Program and Multi-Function buttonsIf you have a hearing aid with a program button or multi-function button, this will allow you to use up to four different listening programs, each of them suitable for certain situations.*Wireless streaming only applicable when using Beltone Direct Line accessories.Note: If you have two hearing instruments with the Ear to Ear Synchronization function enabled and you have the Multifunction Button set for volume control functionality, volume adjustments to one instrument will automatically repeat in the second instrument. When a volume control adjustment is made in one instrument, you will hear a confirmation beep. A beep in the second instrument will follow.
20 21Program number Type of program Intended for1234When using the program or multi-function buttons to switch programs, each press will move the instrument to the next program.  For example, if it was in program 1 it will switch to program 2, if it was in program 2 it will switch to program 3 etc. If programs 2, 3 or 4 are not activated, nothing will happen. Your instrument will give an audible signal after pressing the program or multi-function buttons. A little later, the instrument will give:• one single beep if set in program 1• two beeps if set in program 2• three beeps if set in program 3• four beeps if set in program 4When you close the battery door and switch the instrument on, it will start in program 1. Press the program or multi-function buttons if you want to move to a different listening program.Let your hearing care practitioner fill out the following table:Note:  If you have two hearing instruments with the Ear to Ear Synchronization function enabled, program changes to one instrument will automatically repeat in the second instrument. When a program change is made in one instrument, you will hear the same amount of confirmation beeps in the second instrument.
22 23Telephone useYour hearing instrument allows you to use the telephone as you ordinarily do. Hold the phone up to your ear as you normally would. It is possible you will hear clearer if you hold the phone towards the top of your ear (closer to where the microphones are located).If you experience discomfort from the dome pressing in your ear canal, you may need a different size sound tube. In this case contact your hearing care professional. Your  hearing  care  professional  can  design  a  telephone  program  that  you  can switch to when using the phone. This program is designed to ease listening on a phone. If you have a hearing instrument with a program button, you can switch to this program manually. Your hearing care professional can also enable the Auto-phone function to switch to the telephone program automatically.Auto-PhoneThe Auto-Phone function, allows your hearing instrument to automatically switch to your telephone program when a telephone receiver is raised to the ear. When the telephone receiver is removed from the ear, the hearing instrument automatically returns to the previous listening program.Placement of Auto-Phone magnetsPlace Auto Phone magnet on your telephone receiver to allow operation of the Auto Phone function. In order to place magnets properly:1.  Clean the telephone receiver thoroughly.2.  Hold the telephone vertically, in a position similar to when making a telephone call.3.  Place the magnets just below the telephone receiver. Make sure not to cover the microphone openings. If necessary, move the magnet to another position to improve ease of use and comfort while speaking.4.  If you are not satisfied with the strength of Auto Phone, you can reposition the Auto Phone magnet or add additional Auto Phone magnets.i Only use recommended cleaning agent to clean the telephone prior to placing the magnet on the phone in order to obtain best possible adherence.Auto-Phone usageTelephones can be used in a normal manner. A short melody will indicate that the Auto-Phone feature has automatically switched to the program designed specifically for listening on the phone. Initially, you may need to move the telephone receiver slightly to find the best position for reliable Auto-Phone activation and good hearing on the telephone. If the switching mechanism is not reliable or consistent, additional magnets can be placed on the telephone.i  Auto-Phone precautions1.  Keep magnets out of reach of pets, children and mentally challenged persons. If a magnet is swallowed, please seek advice from a medical practitioner.2.  The magnet may affect some medical devices or electronic systems. The manufacturer of any magne-tically sensitive devices (e.g. pacemakers) should advise you regarding appropriate safety precautions when using your hearing instrument and magnet in close proximity to the medical device or electronic system in question.
24 25T-program (64DW Only)Your hearing instrument has a built-in function, enabling in many cases an improved use of the telephone and better hearing in churches or halls where an induction loop system is installed. In order to activate this function, the telecoil program has to be selected (often available in program 2). In this program you will hear no sounds from the microphone, therefore most environmental sounds will be lost. If you wish, your hear-ing care professional can change the setting in such a way that you hear the microphone and the telecoil simultaneously. Note: For Hearing Instruments in the True family (Models TRUXXXX-YYY), when the telecoil program has been selected, the wireless system will be disabled and it will not be possible to use the wireless remote control or receive a phone call using the Phone Link.Using the telephone• Switch your instrument to the telecoil program.• Hold your telephone handset behind your ear, close to the hear ing  instru-ment (2-3 cm.) and slightly tilt the receiver outwards.Hearing through an induction loopMore and more public places, churches, theatres and cinemas, have induction loops systems. In these par-ticular rooms, they transmit, inductively, the sound of the presenter or show. At home, radio or television can be connected to an induction loop system. Sound quality through induction loop is often better because noises from the environment are not transmitted. • Switch your instrument to the telecoil program. • Choose a good spot. Reception is not clear in all locations; it depends on the position of the induction loop. Watch for signs or try a different seat yourself.• After the service or show, switch your instrument back to the microphone program. You will now hear through the microphone again.• If the sound of your hearing instrument in the telecoil program is very soft all the time, ask your hearing care practitioner to make an adjustment.• Your hearing care practitioner will gladly provide you with advice regarding an induction loop system at home. Please ask for it.3.  If the manufacturer cannot issue a statement, we recommend keeping the magnet or a telephone equip-ped with the magnet 30 cm (12”) away from magnetically sensitive devices (e.g. pacemakers).4.  High distortion during dialing or phoning may mean that the magnet is not in the optimal position relative to the telephone receiver. To avoid the issue, please move the magnet to another place on the telephone receiver. 5.  Only use magnets supplied by Beltone• Listen to the dail tone and move the handset a little to find the position that gives the best reception.• After completing the phone call, switch your instrument back to the microphone program.If the phone has a poor telecoil signal, use the microphone program. Do not hold the handset too tightly against your ear since this might cause ’whistling’.
26 27Listen to radio or tv When listening to the TV or the radio, start out by listening to news commentators since they usually speak clearly, then try other programmes. If you find it difficult to listen to TV or radio, your hearing care professional will be able to give you advice on available accessories to enhance your listening capabilities for TV and radio. Using Beltone hearing instruments with smart phone appsi Intended use of smart phone apps:Beltone smart phone apps are intended to be used with Beltone wireless hearing aids. Beltone smart phone apps send and receive signals from the Beltone wireless hearing aids via smart phones for which the apps have been developed.Use with smart phone apps:• Notifications of app updates should not be disabled, and it is recommended that the user installs all updates to ensure that the app will function correctly and will be kept up to date.• The app must only be used with Beltone devices for which it is intended, and Beltone take no responsi-bility if the app is used with other devices.Cellular phones Your hearing instrument is designed to comply with the most stringent Standards of International Electro-magnetic Compatibility. However, not all cell phones are hearing instrument compatible. The varying de-gree of disturbance can be due to the nature of your particular cellular phone or of your wireless telephony service provider. If you find it difficult to obtain a good result while using your cellular phone, your hearing care professional will be able to give you advice on available accessories to enhance listening capabilities. Audio input (64DW Only) Your hearing instrument is equipped with a direct audio input fa cility. Direct audio input allows direct con-nection of sound sources, a radio, television or even school equipment, to your hearing instrument. Often, this will improve sound quality.• The sound source is connected to your instrument  with a cable and an audio shoe.• The instrument automatically detects the direct  audio input source. The direct audio input supports the systems for the wireless use as well.• In this program you will hear no sounds from the microphone, therefore most environmental sounds will be lost. If you wish, your hearing care practitioner can change the setting in such a way that you hear the microphone and the direct audio input simultaneously.Note: For Hearing Instruments in the True family (Models TRUXXXX-YYY), when the Direct Audio Input has been activated, by correctly placing the Audio shoe, the wireless system will be disabled and it will not be possible to use the wireless remote control or receive a phone call using the Phone Link.i  External devices connected to the electrical input must be safe according to the requirements of IEC 60601-1-1, IEC 60065, or IEC 60950-1, as appropriate.
28 29Flight mode iWhen boarding a flight or entering an area where RF transmitters are prohibited, wireless functionality must be deactivated as it is not allowed to radiate radio signals during flights or in otherwise restricted areas. Follow these steps to enter and leave flight mode:For Beltone True Hearing Instruments It is possible to disable wireless operation by opening and closing the battery compartment of the hearing instrument while at the same time pressing the program button.When disabled manually, wireless operation may be re-enabled by opening and closing the battery com-partment normally (i.e. without pressing the program button). 10 seconds after this operation is completed, wireless operation will begin again. For all other wireless hearing instruments:It is possible to disable wireless operation by performing the following sequence of operations. Note that this operation is the same for both hearing instruments with and without a program button.Close the battery door (Hearing instrument is turned on)Open the battery door within 10 seconds of doing operation #1 (Hearing instrument is turned off)Close the battery door (Hearing instrument is turned on 2nd time)Open the battery door within 10 seconds after doing operation #3 (Wireless is turned off 2nd time)Close the battery door (Hearing instrument is turned on 3rd time)When disabled manually, it is possible to re-enable wireless operation by opening and closing the battery door. 10 seconds after this operation is completed, wireless operation will begin again. Daily maintenanceKeep your hearing instrument clean and dry. Wipe the case with a soft cloth or tissue after use to remove grease or moisture. You should avoid exposing your instrument directly to moisture such as rain or water from the shower. If your instrument does get wet or if it has been exposed to high humidity or perspiration, it should be left to dry out overnight with the battery out and the battery compartment open. It is also a good idea to put them in a sealed container together with a drying agent (dessicator) overnight. Consult your hearing care professional as to which drying agent to use.Your hearing instrument is protected by a protective, hydrophobic nanocoat material: HPF80 NanoBlock. It will improve the durability of you hearing instrument by repelling moisture and debris. However, to avoid the need for unwarranted repairs: • Never immerse the instrument in water or other liquids since this may cause permanent damage to the circuitry.• Protect your hearing instrument from rough handling, and avoid dropping it on hard surfaces or floors. • Do not leave the instrument in or near direct heat or sunlight since excessive heat can damage the in-strument or deform the casing or the receiver tube.• Remove your hearing instrument when applying such things as cosmetics, perfume, aftershave, hair spray, and suntan lotion. These might get into the instrument and cause damage.
”NP””S””HP” ”UP”30 31The receiver tubeThe receiver tube comes in three different types;“S” (Small Size), “NP” (Normal Power) and “P” (Power)Please see illustrations.Depending on your hearing loss you have either been fitted with the “S”, the “NP” or the “P” receiver type. Please see page 48-52 to see your selected type. The receiver tube contains the wiring to the re-ceiver which delivers the sound direct in the ear canal. It is important that the receiver tube and the receiver dome/RIE mold fit correctly into your ear. If the receiver tube or the receiver dome/RIE mold irritate your ear in any way and prevent you from wearing your hearing instrument, please contact your hearing care professional. You should never at-tempt to modify theshape of the receiver tube yourself. The receiver tube and the receiver dome/RIE mold should be cleaned regularly. Cleaning the receiver tube and the receiver domesThe receiver tube and the receiver dome should be cleaned regularly. Use a damp cloth to clean the receiver tube and receiver dome on the outside. Do not use water when you are cleaning the receiver tubes or the receiver domes.Cleaning the RIE or UP moldWe recommend that you use a damp cloth to clean the RIE mold after every time you use it. It’s important to keep it clean from wax so that you will not have wax or bacteria building up on the mold.If you no longer can clean the RIE mold using a damp cloth we recommend you to contact your hearing care professional for them to clean it, using water and soap. If desired, you can have your hearing care profes-sional instruct you how to clean the RIE mold yourself.
32 33The receiver domesThe receiver Mini Dome / Tulip Dome / Power Dome should be changed every third month or sooner if needed. We recommend that you have your hearing care professional change the receiver Mini Dome / Standard Dome / Power Dome for you. If your hearing care professional instructs you to change the receiver domes yourself, make sure that they are securely fastened to the receiver tube before inserting them in your ear. A failure to change the domes in accord ance with the instructions could result in injury.Wax guard filtersYour hearing instruments have been fitted with wax guard filters to in crease the protection against wax and moisture from damaging the hearing instrument.We recommend that your hearing care professional change them for you. If desired, you can have your hearing care professional instruct you how to change the wax guard filters yourself.Tinnitus Breaker ProYour Beltone hearing instrument models may also include a tinnitus sound generator function, a tool for generating sounds to be used in tinnitus management programs to relieve suffering from tinnitus. Tinnitus Breaker Pro can generate sounds adjusted to the specific therapeutic needs and your personal preference as determined by your doctor, audiologist, or hearing care professional.Depending on the selected hearing instrument program and the environment you are in, you will sometimes hear the therapeutic sound resembling a continuous or fluctuating whistling.If you have two hearing instruments with the Ear to Ear Synchronization function enabled, Tinnitus Breaker Pro will generate the same sound in both instruments simultaneously.Important Notice to Prospective UsersGood health practice requires that a person with a hearing loss and/or a tinnitus condition has a medical evaluation by a licensed phy sician (preferably a physician who specializes in diseases of the ear)before us-ing a hearing instrument and/or a sound generator. The purpose of a medical evaluation is to ensure that all medically treatable conditions that may affect hearing and/or tinnitus are identified and treated before the hearing instrument and/or sound generator is used.The sound generator instrument is a tool to generate sounds to be used with appropriate counseling and/or in a tinnitus management program to relieve patients suffering from tinnitus.
34 35Prescription Use for Sound Generator Users Please use the device as prescribed by your doctor, audiologist, or hearing care professional. Should you develop any side effects from using the instrument, such as dizziness, nausea, headaches, perceived de-crease in auditory function or increase in tinnitus perception, you should discontinue use of the device and seek medical evaluation.The target population is primarily the adult population over 18 years of age. This product may also be used with children 5 years of age or older. However, children and physically or mentally challenged users will require training by a doctor, audiologist, hearing care professional or the guardian for the insertion and removal of the device.CAUTION – Tinnitus Sound Generator iThe maximum output of the Tinnitus Breaker Pro feature falls into the range that can cause hearing loss according to OSHA regulations.The user should not use the sound generator for more than eight (8) hours a day when this is set below  90dB SPL. Above that level, the device should not be used for more than two hours per day. In no case should the sound generator be worn at uncomfortable levels.Children and physically or mentally challenged users will require guardian supervision while wearing the device.General warnings/or precautionsHearing instruments and sound generators can be dangerous if improperly used.Sound generators should be used only as advised by your doctor, audiologist, or hearing care professional.Sound generators are not toys and should be kept out of reach of anyone (especially children and pets) who might cause themselves injury.
36 37General precautions i• Special care should be exercised in selecting and fitting a hearing instrument(s) who’s maximum sound pressure level exceeds 132 dB SPL (with an IEC 60711:1981 occluded ear simulator), because there may be a risk of impairing the remaining hearing of the hearing instrument user. • Do not leave your instrument in the sun, near an open fire or in a hot, parked car.• Do not wear your instrument while showering, swimming, in heavy rain or in a moist atmosphere such as steam bath or sauna.• Should your instrument become moist, put it in a dessicator. Your hearing care professional will be happy to counsel on this.• Remove your instrument when applying cosmetics, e.g. perfume, aftershave, hair spray, suntan lotion.• Wearing an instrument might cause an increased production of earwax. In rare cases, the anti-allergenic materials may cause skin irritation. If so, or if in doubt, consult your physician or ENT.• For use of wireless functionality, only use Beltone Direct Line accessories. For further guidance, please refer to the relevant Beltone Direct Line user guide.• Only connect Beltone hearing instruments to Beltone accessories intended and qualified to be used with Beltone hearing instruments.• When wireless function is activated, the device uses low-powered digitally coded transmissions in order to communicate with other wireless devices. Although unlikely, nearby electronic devices may be af-fected. In that case, move the hearing instrument away from the affected electronic device.• When using wireless functionality and the devices are affected by electromagnetic interference, move away from the source of interference.General warnings iHearing instruments can be dangerous if improperly used.• Consult a physician if you find a foreign object in your ear canal, if you experience skin irritation or if excessive ear wax accumulates with the use of the instrument.• Different types of radiation, (e.g. from X-ray, MRI, NMR, CT scans), may damage the instrument. There-fore, do not wear the instrument during these or other corresponding scanning procedures. Other types of radiation (burglary alarms, room surveillance systems, radio equipment, mobile telephones, etc) will not damage the instrument. They could, however, momentarily affect the sound quality or create strange sounds from the instruments. • Do not wear the instrument in mines or other explosive areas, unless those areas are certified for hearing instrument use.• Do not allow others to use your hearing instrument. This may cause damage to the hearing instruments or to the hearing to the other individual.• Instrument usage by children or mentally challenged persons should be supervised at all times to ensure their safety.• Instruments should be used only as prescribed by your hearing care professional. Incorrect use may result in sudden and permanent hearing loss.i This device operates in the frequency range of 2.4 GHz - 2.48 GHz. (63DW and 64DW models)This device includes a RF transmitter that operates in the range of 2.4 GHz - 2.48 GHz. (63DW and 64DW models)
38 39• The instrument contains small parts that could be swallowed by children. Please be mindful not to leave children unsupervised with this hearing instrument.• Turn off your wireless functionality by using flight mode in areas where radio frequency emmissions are prohibited.• Be careful when boarding flights to deactivate the wireless functionality• If device is broken, do not use.Eight steps towards better hearingYou need to get used to your new hearing instrument. Sounds seem new and different. That is because you grew accustomed to your diminished hearing. Therefore, familiar sounds seem strange or unnatural at first. Every first-time user of a hearing instrument responds differently to this. Some can wear the new instrument a whole day right from the start, while others find it hard to get used to.After a while, you will notice you appreciate hearing with a hearing instrument and that you will find it quite normal. Below, eight steps are described that will guide you through the initial period. If you are not satisfied or keep experiencing problems, please consult yourhearing care practitioner.1. Get used to familiar sounds at homeTry to get used to the new sounds from a familiar environment. Listen to the different (background) sounds and try to recognise them. When you are tired from listening, remove your instrument and pause for a while. Talk or read aloud for a while. In that way you will familiarise yourself with the sound of your own voice. Gradually, you will learn to use the instrument for longer and become more comfortable with it.2. Listen outside; quiet & trafficGo outside to a quiet place, e.g., the park or woods. Listen to the environmental sounds. Do you recognise them? Please be careful with sounds from heavy traffic at this stage of getting used to your instrument. Sometimes it sounds very loud. Try not to get frightened.3. Have a conversation with a single personUse your instrument in conversation with one person, a family member or a friend. Move to a quiet spot. Explain that you are now wear ing a hearing instrument. Ask the other person to talk normally. Look at your conversation partner. If your instrument is tuned to your requirements you will be able to communicate bet-ter than before.4. Listen to radio or televisionListen to the radio or television. Start with the news, then turn to another program. Ask a ‘normal hearing’ person to set the volume of your radio or television to a comfortable level. If necessary, adjust the volume on your hearing instrument.If you cannot understand the radio or television, ask your hearing care practitioner to adjust your hearing instrument.5. Get used to conversations in a groupFollowing conversations in a group is often difficult because of the background noise. Listen to the different voices. Try to recognise them by timbre or rhythm and link each voice to a person. Focus your attention on the person you want to understand. Practice this regularly.
40 41If you did not understand something that was said, please ask for itto be repeated.Ensure that you can see the face of your conversation partner(s) clearly and that there is sufficient light. This will help you to lipread. Avoid ‘looking into the light’. Position yourself with your back towards the window, so that you can see the other person(s) better. Ask others to talk slowly and clearly. Talking louder does not help.6. Visit public buildingsVisit public buildings. Try to sit near the speaker; try to be seated in the front rows in a show. Avoid a seat behind a pillar or in an alcove, you will be in a ‘sound shadow.’In a restaurant, sit with your back towards the wall. This avoids disturbing noises coming from behind you.7. Use your telephoneOften, you can hear the telephone clearly with your hearing instrument in a microphone program. Hold the telephone handset 1-inch (2-3cm) from your ear and tilt the receiver outwards a little.Your hearing instrument meets strict international regulations. Therefore, it should be possible to use a GSM telephone in most cases.However, in some circumstances, disturbance might be audible through your hearing instrument.8. Use your instrument all dayUsing your hearing instrument and practising with it is the best way to learn to hear again. Even if you can hear without an instrument in some cases. Try to wear your instrument all day. In that way, you will benefit the most.Of course, a hearing instrument cannot restore natural hearing, but it will help you make the most of your hearing as it is today.Go beyond these eight steps and discover the world of sound around you. Do the things you enjoy and listen to the sounds from your environment.
42 43SYMPTOM CAUSE POSSIBLE REMEDYDevice is dead Not turned on Turn onDead battery Replace batteryBattery improperly inserted Insert battery properlyBroken receiver or receiver tube Consult your hearing care professionalBlocked wax guard filter Consult your hearing professional or if you have been in structed change receiver dome or/and wax guard filterNot loud enough Receiver dome not inserted properly Reinsert carefullyBlocked wax guard filter Consult your hearing professional or if you have been in structed change receiver dome or/and wax guard filterChange in hearing Consult your hearing care professionalExcessive ear wax Consult your physicianHearing instrument settings not optimum Consult your hearing care professionalTROUBLESHOOTING GUIDE
44 45SYMPTOM CAUSE POSSIBLE REMEDYWhistles Receiver tube and receiver dome not inserted properly in the ear Reinsert carefullyHearing instrument settings not optimum  Consult your hearing care professionalNot clear, distorted Weak battery Replace batteryPoorly fitting receiver tube Consult your hearing care professionalHearing instrument damaged Consult your hearing care professionalHearing instrument settings not optimum Consult your hearing care professionalTROUBLESHOOTING GUIDE
46 47Technical specificationsAudio signal technologyDigitalAvailable sounds – Tinnitus Breaker Pro sound generatorWhite noise signal which can be shaped with the following configurations:- High-pass filter: 500Hz- High-pass filter: 750Hz- High-pass filter: 1000Hz- High-pass filter: 1500Hz- High-pass filter: 2000Hz- Low-pass filter: 2000Hz- Low-pass filter: 3000Hz- Low-pass filter: 4000Hz- Low-pass filter: 5000Hz- Low-pass filter: 6000HzThe white noise signal can be modulated in amplitude with an attenuation depth of up to 14dB. Hearing instrument maximum output and Tinnitus Breaker Pro sound generator maximum overall output (IEC 118-0 OES)Model Hearing instrument max output(IEC 118-0 OES)Tinnitus Breaker Pro soundgenerator max overall output (IEC 118-0 OES)TRU62D 125 dB SPL 90 dB SPLTRU62DO 124 dB SPL 90 dB SPLTRU62DP 128 dB SPL 90 dB SPLTRU62DPO 128 dB SPL 90 dB SPLTRU63DW 125 dB SPL 90 dB SPLTRU63DWO 124 dB SPL 90 dB SPLTRU63DPW 128 dB SPL 90 dB SPLTRU63DPWO 128 dB SPL 90 dB SPLTRU64DW 125 dB SPL 90 dB SPLTRU64DWO 124 dB SPL 90 dB SPLTRU64DPW 128 dB SPL 90 dB SPLTRU64DPWO 128 dB SPL 90 dB SPL
49Model Hearing instrument max output (IEC 118-0 OES)Tinnitus Breaker Pro soundgenerator max overall output (IEC 118-0 OES)PSE64-DRPW 128 dB SPL 90 dB SPLPSE64-DRPWO 128 dB SPL 90 dB SPLPSE64-DRW 125 dB SPL 90 dB SPLPSE64-DRWO 124 dB SPL 90 dB SPLPSE64-DRSW 123 dB SPL 90 dB SPLPSE64-DRSWO 123 dB SPL 90 dB SPLPSE63-DRPW 128 dB SPL 90 dB SPLPSE63-DRPWO 128 dB SPL 90 dB SPLPSE63-DRW 125 dB SPL 90 dB SPLPSE63-DRWO 124 dB SPL 90 dB SPLPSE63-DRSW 123 dB SPL 90 dB SPLPSE63-DRSWO 123 dB SPL 90 dB SPLPSE62-DRP 128 dB SPL 90 dB SPLPSE62-DRPO 128 dB SPL 90 dB SPLPSE62-DR 125 dB SPL 90 dB SPLPSE62-DRO 124 dB SPL 90 dB SPLPSE62-DRS 123 dB SPL 90 dB SPLPSE62-DRSO 123 dB SPL  90 dB SPLModel Hearing instrument max output (IEC 118-0 OES)Tinnitus Breaker Pro soundgenerator max overall output (IEC 118-0 OES)FI1763-DRW 126 dB SPL 90 dB SPLFI1763-DRSW 124 dB SPL 90 dB SPLFI1763-DRPW 129 dB SPL 90 dB SPLFI1763-DRUW 136 dB SPL 90 dB SPLFI963-DRW 126 dB SPL 90 dB SPLFI963-DRSW 124 dB SPL 90 dB SPLFI963-DRPW 129 dB SPL 90 dB SPLFI963-DRUW 136 dB SPL 90 dB SPL
50 51Temperature test, transport and storage informationBeltone Hearing Instruments are subjected to various tests in temperature and damp heating cycling between -25 C and +70C according to internal and industry standards.During transport or storage, the temperature should not exceed the limit values of -20C (68F) to 60C (140F) and relative humidity of 90% RH, non condensing (for limited time). The air pressure between 500 and 1100 hPa (mbar) is appropriate.International warranty, service and repairsBeltone provides a warranty on hearing instruments in the event of defects in workmanship or materials, as described in applicable warranty documentationIn its service policy, Beltone pledges to secure functionality at least equivalent to the original hearing instru-ment.As a signatory to the United Nations Global Compact initiative, Beltone is committed to doing this in line with environment-friendly best practices. Hearing instruments therefore, at Beltone’s discretion, may be replaced by new products or products manufactured from new or serviceable used parts, or repaired using new or refurbished replacement parts.The warranty period of hearing instruments is designated on your warranty card, which is provided by your hearing care professional.If your Beltone hearing instrument malfunctions, it must be repaired by a qualified technician. Do not at-tempt to open the case of the hearing instrument since this would invalidate the warranty. If your Beltone hearing instrument requires service, please contact your hearing care professional for assistance.
52 53Beltone True Type BatterysizeReceiver tube type and length/sizeTRU1764DW RIE 312TRU1764DWO RIE 312TRU1764DPW RIE 312TRU1764DPWO RIE 312TRU964DW RIE 312TRU964DWO RIE 312TRU964DPW RIE 312TRU964DPWO RIE 312TRU664DW RIE 312TRU664DWO RIE 312TRU664DPW RIE 312TRU664DPWO RIE 312TRU1763DW RIE 312TRU1763DWO RIE 312TRU1763DPW RIE 312TRU1763DPWO RIE 312Beltone True Type BatterysizeReceiver tube type and length/sizeTRU963DW RIE 312TRU963DWO RIE 312TRU963DPW RIE 312TRU963DPWO RIE 312TRU663DW RIE 312TRU663DWO RIE 312TRU663DPW RIE 312TRU663DPWO RIE 312TRU363DW RIE 312TRU363DWO RIE 312TRU363DPW RIE 312TRU363DPWO  RIE 312PSE1764-DRPW RIE 312PSE1764-DRPWO RIE 312PSE1764-DRW RIE 312PSE1764-DRWO RIE 312PSE1764-DRSW RIE 312PSE1764-DRSWO RIE 312PSE1763-DRPW RIE 312Your selected modelYour hearing care professional place a check mark in the below table to identify the model you have received.
54 55Beltone True Type BatterysizeReceiver tube type and length/sizePSE1763-DRPWO RIE 312PSE1763-DRW RIE 312PSE1763-DRWO RIE 312PSE1763-DRSW RIE 312PSE1763-DRSWO RIE 312PSE964-DRPW RIE 312PSE964-DRPWO RIE 312PSE964-DRW RIE 312PSE964-DRWO RIE 312PSE964-DRSW RIE 312PSE964-DRSWO RIE 312PSE963-DRPW RIE 312PSE963-DRPWO RIE 312PSE963-DRW RIE 312PSE963-DRWO RIE 312PSE963-DRSW RIE 312PSE963-DRSWO RIE 312PSE664-DRPW RIE 312Beltone True Type BatterysizeReceiver tube type and length/sizePSE664-DRPWO RIE 312PSE664-DRW  RIE 312PSE664-DRWO  RIE 312PSE664-DRSW RIE 312PSE664-DRSWO RIE 312PSE663-DRPW RIE 312PSE663-DRPWO  RIE 312PSE663-DRW  RIE 312PSE663-DRWO  RIE 312PSE663-DRSW  RIE 312PSE663-DRSWO RIE 312TRU1762D RIE 10ATRU1762DO RIE 10ATRU1762DP RIE 10ATRU1762DPO RIE 10ATRU962D RIE 10ATRU962DO RIE 10ATRU962DP RIE 10ATRU962DPO RIE 10A
Beltone True Type BatterysizeReceiver tube type and length/sizeTRU662D RIE 10ATRU662DO RIE 10ATRU662DP RIE 10ATRU662DPO RIE 10APSE1762-DRP RIE 10APSE1762-DRPO RIE 10APSE1762-DR RIE 10APSE1762-DRO RIE 10APSE1762-DRS RIE 10APSE1762-DRSO RIE 10APSE962-DRP RIE 10APSE962-DRPO RIE 10APSE962-DR RIE 10APSE962-DRO RIE 10APSE962-DRS RIE 10APSE962-DRSO RIE 10ABeltone True Type BatterysizeReceiver tube type and length/sizePSE662-DRP  RIE 10APSE662-DRPO  RIE 10APSE662-DR  RIE 10APSE662-DRO  RIE 10APSE662-DRS  RIE 10APSE662-DRS  RIE 10AFI1763-DRW RIE 312FI1763-DRSW RIE 312FI1763-DRPW RIE 312FI1763-DRUW RIE 312FI963-DRW RIE 312FI963-DRSW RIE 312FI963-DRPW RIE 312FI963-DRUW RIE 312
58 59Be aware of information marked with the warning symbol i   WARNING points out a situation that could lead to serious injuries,  CAUTION indicates a situation that could lead to minor and moderate injuries. Equipment includes RF transmitter.   Product is a Type B applied part.i   Advice and tips on how to handle   your hearing instrument better.Please ask your local hearing care professionalconcerning disposal of your hearing instrumenti “Made for iPhone” means that an electronic accessory has been designed to connect specifically to iPhone and has been certified by the developer to meet Apple performance standards.Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that the use of this accessory with iPhone may affect wirelessperformance.
© Beltone 2012400151000-GB-13.07-Rev.DWorldwide headquarters Beltone A/SLautrupbjerg 7DK-2750 BallerupDenmarkTel.: +45 45 75 11 11Fax: +45 45 75 11 19www.beltone-hearing.comCVR no. 55082715Any issues relating to the EU Medical Device Directive 93/42/EEC, or Council Directive 1999/5/EEC on Radio Equipment and Telecommunications Terminal Equipment should be directed to Beltone A/S.