GS Instech GSR-2630D-SPR RF Repeater User Manual ATT E

GS Instruments Co., Ltd. RF Repeater ATT E

Manual

Download: GS Instech GSR-2630D-SPR RF Repeater User Manual ATT E
Mirror Download [FCC.gov]GS Instech GSR-2630D-SPR RF Repeater User Manual ATT E
Document ID1008451
Application IDP8yS54ODY3dj1XkwIHzLWQ==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize29.22kB (365274 bits)
Date Submitted2008-09-29 00:00:00
Date Available2008-11-10 00:00:00
Creation Date2008-09-12 17:15:04
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2008-09-12 17:15:04
Document TitleMicrosoft Word - ATT.E User Manual.doc
Document CreatorPScript5.dll Version 5.2
Document Author: Siegfreid

FCC ID : U88-GSR-2630D-SPR
ATTACHMENT E.
- USER MANUAL -
HCT CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCT-R08-163
1/1
SPRINT User Manual
WIMAX_30dBm
July, 2008
Version 1.0
SPRINT User Manual
WIMAX 30dBm
- INDEX 1. SUMMARY................................................................................... 3
2. SYSTEM STRUCTURE .................................................................. 4
2.1 Network structure for WIMAX RF Repeater............................. 4
2.2 System Design and Operation.................................................. 5
2.2.1 System design………………………………………………………………….………5
2.2.2 Downlink Path………………………………………………………………………….7
2.2.3 Uplink Path…………………………………………………………………………….8
3. SPECIFICATIONS ....................................................................... 9
3.1 System Specifications .............................................................. 9
3.2 Electrical and Environment Specifications ............................. 10
3.3 Functions........................... 오류! 책갈피가 정의되어 있지 않습니다.
4. SET UP ...................................................................................... 11
4.1. Equipment needed for iDEN Repeater Setup ........................ 11
4.1.1 Notice…………………………………………………………………………………..11
4.1.2 System set up……………………………………………………………………….12
4.1.3 Open for service…………………………………………………………………….12
4.2 Troubleshooting ..................................................................... 12
4.2.1 Necessary Testing and measuring equipment……………………………12
4.2.2 Notice…………………………………………………………………………………..12
4.2.3 Troubleshooting Guide……………………………………………………………13
4.2.4 Troubleshooting Guide Related to RF………………………………………..오류!
책갈피가 정의되어 있지 않습니다.
4.2.5 Troubleshooting Guide Related to NMS…………………………………….오류!
책갈피가 정의되어 있지 않습니다.
SPRINT User Manual
WIMAX 30dBm
1. SUMMARY
GSTR-2630D-SPR is an in-building solution for extending and improving WiMAX coverage area in
Sprint network, providing better signal quality in small stores, manufacturing facilities, warehouses,
etc. GSTR-2630D-SPR eliminates PN pollution to decreasing noise in Sprint’s BTS.
# GRS-2630D-SPR Main Features #
- Conversion type
- DNC/IF/UPC integration module is implemented.
- D/L & U/L S/W LNA
- Sync Detection Module achieved sync. Signal then process the sync signal.
- D/L ALC, U/L ALC function
- Gain Balance function to be interfaced with D/L and U/L Gain
Abbreviation
LNA: Low Noise Amplifier
PSU: Power Supply Unit
HPA: High Power Amplifier
SDM: Sync Detection Module
Caution: Replaceable batteries instruction
Risk of explosion if battery is replaced by an incorrective type.
Dispose of used batteries according to the instructions.
SPRINT User Manual
WIMAX 30dBm
2. SYSTEM STRUCTURE
2.1 Network structure for WIMAX Indoor RF Repeater
Below picture shows a Network structure for WIMAX Indoor RF Repeater in a real site. Donor ANT
takes a position on the direction to BTS which be linked, and Server ANT is available to be located
in designated area for service by using RF cable deployments and dividers as blow.
One thing that we consider is Path losses between Repeater port and ANT in case of dividing by
dividers and RF cables. They should be equally managed.
 WIMAX Indoor RF Repeater Service Organization
SPRINT User Manual
WIMAX 30dBm
2.2 System Design and Operation
2.2.1 System design
SERVER
DONOR
RF IN
▼
①
①
②
②
1. +7Vdc
2. LNA_ALM
OUT2
3. -12Vdc
4.5.9 NC
ANT2
6. TTL1
7. DET 1
8. GND
COUP2
INTERFACE
▼
⑤
④
8. GND
7. TTL2
6. TTL1
HPA
4.5.9 NC
3. -12Vdc
2. ALM
1. +7Vdc
COUP1
8. GND
ANT1
7. DET1
6. TTL1
4.5.9 NC
3. -12Vdc
OUT1
2. LNA_ALM
1. +7Vdc
RF OUT
▼
⑦
POWER
⑥
⑧
DC_F AC_F
GND -12V
GND +12V
GND GND SUB
+7V +7V
GND GND
+27V +27V
⑨
③
F.G
AC_INPUT AC_N
AC_L
ALM DC AC
⑩
NO.
PART
NO.
PART
①
ARRESTOR
⑦
CONVERTER MODULE
②
CAVITY FILTER MODULE
⑧
NMS BOARD
③
PSU MODULE
⑨
I/O, RFC BOARD
④
LNA MODULE
⑩
ETHERNET PORT
⑤
HPA MODULE
⑥
SDM MODULE
 WIMAX Repeater 30dBm Internal Design
SPRINT User Manual
WIMAX 30dBm
NO.
PORT
NO.
PORT
①
DONOR ANT PORT
④
AC POWER PORT
②
SERVER ANT PORT
⑤
CLI PORT
③
DC POWER PORT
⑥
ETHERNET PORT
 WIMAX Repeater 30dBm PORT Design
SPRINT User Manual
WIMAX 30dBm
2.2.2 Downlink Path
GRS-2630D-SPR is basically designed to select 33MHz operational bandwidth from entire BRS
bandwidth (188MHz). Repeater would smartly select actual Sprint operational bandwidth such as
2502~2568MHz (ABCD), 2624~2690MHz (EFHG) using local frequency without interfering into
in-band.
To discriminate Tx / Rx circuit, GRS-2630D-SPR is implemented Bias, including LNA and HPA to
functionate switching operation. In the LNA, SPDT switch is implemented not only to improve
Tx/Rx separation, but to protect Rx circuits, when antenna is open.
 WIMAX 30dBm RF Repeater Downlink Block Diagram
SPRINT User Manual
WIMAX 30dBm
2.2.3 Uplink Path
GRS-2630D-SPR is basically designed to select 33MHz operational bandwidth from entire BRS
bandwidth (188MHz). Repeater would smartly select actual Sprint operational bandwidth such as
2502~2568MHz (ABCD), 2624~2690MHz (EFHG) using local frequency without interfering into
in-band.
To discriminate Tx / Rx circuit, GRS-2624D-SPR is implemented Bias, including LNA and HPA to
functionate Switching operation. In the LNA, SPDT switch is implemented not only to improve
Tx/Rx separation, but to protect Rx circuits, when antenna is open.
GRS-2624D-SPR Downlink, Uplink Converter Module’s Gain is 20dB for both paths
 WIMAX 30dBm RF Repeater Uplink Block Diagram
SPRINT User Manual
WIMAX 30dBm
3. SPECIFICATIONS
3.1 System Specifications
Parameter
Specifications
Frequency Range
2502MHz ~ 2690MHz
Band Select
(33MHz)
A+B
2502MHz ~ 2535MHz
B+C
2518.5MHz ~ 2551.5MHz
C+D
2535MHz ~ 2568MHz
E+F
2624MHz ~ 2657MHz
F+H
2640.5MHz ~ 2673.5MHz
H+G
2657MHz ~ 2690MHz
Max Gain
80dB ± 1.5dB
Flatness
≤ 3dB (P-P) / Channel
VSWR
Max 1.5 : 1
System Delay
Max 5us
Input
D/L
- 50dBm ~ -20dBm
U/L
- 50dBm ~ -20dBm
D/L
0 ~ 30dB
Accuracy ± 2.0dB
U/L
0 ~ 30dB
Accuracy ± 2.0dB
Power
Range
ALC
Range
ALC
Range
Comment
Roll offs
EVM
30dBc @±1MHz
80dBc @±3.5MHz
≤ 5% (against the source)
±1.55MHz
-13dBm@100kHz
Out of Band
±3.5MHz
-13dBm@1MHz
Emission
±5MHz
-37dBm@1MHz
±8MHz
-37dBm@1MHz
Noise Figure
Frequency Stability
5dB @ Max Gain
12dB @ Min Gain
≤ 0.02ppm
SPRINT User Manual
WIMAX 30dBm
TTG : 0 ~ -105.7us
Switching Adjustment
RTG : 0 ~ -60us
Range
Guard Offset : 0 ~ 30us
Switching Timing
≤ ±1us / 1us
Adjustment Accuracy
Specifications
Parameter
Input Power
D/L
Accuracy
U/L
Output Power
D/L
Accuracy
U/L
Over Power
D/L
33dBm/ Total
Alarm
U/L
33dBm/ Total
U/L
TTG , RTG , Guard Offset
Comment
± 2dB
≤ --55dBm
D/L
RTG: 60us
± 2dB
RSSI Alarm
VSWR Alarm
TTG: 105.71us
Only DL
When Output Port is
open
3.2 Electrical and Environment Specifications
Parameter
Specifications
Comment
Connector Type
N-type Female 2 port
N-Type : DL 1 port, UL 1 port
Size
350mm X 400mm X 215mm
Weight
Max 50 lbs
Power Consumption
90W
Power Source
Remote Operating
Temperature
Remote Operating Humidity
110-125VAC, 60Hz
208-240VAC single phase
-10℃ ~ 50℃
5%~100%
10
4 hour Back up Battery (option)
SPRINT User Manual
WIMAX 30dBm
4. SET UP
4.1. Equipment needed for WIMAX RF Repeater Setup
Parameter
Item
Quantity
Remark
Major Component
Repeater GRS-2630D-SPR
1 EA
Provided by GST
Mounting Bracket
1 EA
Installation Guide Book V. 1.0
1 EA
CD which contains User Manual
and Installation Guide V.1.0
1 EA
Ethernet Cable 2M
1 EA
Power Cord 3M
1 EA
Ground Cable 3M
1 EA
Ground Sems Screw
4 EA
Bracket Sems Screw
4 EA
Lag Screw
4 EA
Anchor Bolt Set
4 EA
Donor ANT
1 EA
Server ANT
1 EA
RF Cable
Antenna connection Cable
TBD
Not Included
Testing and
Measuring Equipment
Spectrum Analyzer
1 EA
Not Included
Additional
components
Antenna
Provided by GST
Not Included
4.1.1 Notice
1) System Power check: Major electricity is AC110V, therefore please input electricity after power verification.
2) Input condition optimization: DL, UL input condition of WiMAX 30dBm is -50 ~ -20dBm
3) This equipment is basically wall mountable installation.
11
SPRINT User Manual
WIMAX 30dBm
4.1.2 System set up
1) This equipment is basically wall mountable.
2) Installer will have to connect the power supply (after input power verification) and RF cable to the
Repeater and then it will be ready to use.
3) For grounding, there is a grounding terminal in main power supply which will be plugged into power outlet.
There is also a separate grounding terminal on the repeater which should be connected to the on-site
grounding terminal to ensure proper grounding.
4) Mounting of repeater should be done by at least two technicians to ensure a safe and proper install.
4.1.3 Open for service
1) Check points before open
a. Verification of system installation status
Electricity, In/out antenna, coaxial cable connection, equipment mounts status.
b. Verification of system accessories
User should check whole necessary accessories.
c. Check receipt signal level
User should check whether receipt environmental condition is in accordance with system specification, so t
hat system operation will be optimized.
4.2 Troubleshooting
4.2.1 Necessary Testing and measuring equipment
a. Signal Generator: 3GHz
b. Spectrum Analyzer: 3GHz
c. Multi-Meter
4.2.2 Notice
a. Troubleshooting should be performed by a trained technician.
b. Parts that seem to be not used should not be disassembled.
c. While troubleshooting, technician should use attenuator to check RF Signal output.
12
SPRINT User Manual
WIMAX 30dBm
4.2.3 Troubleshooting Guide
Item
Check Point
Trouble shooting
Input Level
Note before
* System Input
Down Link
-50dBm/Total ~ -20dBm/Total
system operation
power range
Up Link
-50dBm/Total ~ -20dBm/Total
Gain
Same as above
* System Gain
Down Link
50 ~ 80dB
Up Link
50 ~ 80dB
Output power
Same as above
* Output power at
Down Link
30dBm/Total
edge port side
Up Link
30dBm/Total
* Check points
Check in Advance
before open for
service
* Please check quantity of all accessories with specification
before you set up.
* Fit cable length in accordance with field condition.
* Set up Donor antenna to secure Isolation (More than 87dBc)
13
SPRINT User Manual
WIMAX 30dBm
* Check following status
- Fixable level of antenna support pole
- Connection status between antenna and RF cable
- RF Cable construction and fixed status
- Verify that the Repeater is securely mounted
- Electricity construction and proper AC power status
Check after open
* Check points after
- Plug status and electricity voltage status
open for service
- Wall socket and voltage status
- Grounding status of electrical circuit
- Direction of Donor antenna
(PN Offset and neighborhood BTS to be considered.)
- Coaxial cable construction status
- Connector combiner connection status
- Cable connection status against leakage of water
14

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-702
Modify Date                     : 2008:09:12 17:15:04+09:00
Create Date                     : 2008:09:12 17:15:04+09:00
Metadata Date                   : 2008:09:12 17:15:04+09:00
Creator Tool                    : PScript5.dll Version 5.2
Format                          : application/pdf
Title                           : Microsoft Word - ATT.E User Manual.doc
Creator                         : Siegfreid
Document ID                     : uuid:75911b2e-2d03-4b5f-8610-9534f17a1046
Instance ID                     : uuid:9ce807ec-6985-4008-a80d-2abb1849000e
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Page Count                      : 15
Author                          : Siegfreid
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U88-GSR-2630D-SPR

Navigation menu