GS Instech GSTR-815DC-SPR Inbuilding RF Repeater User Manual Manual

GS Instruments Co., Ltd. Inbuilding RF Repeater Manual

Manual

Download: GS Instech GSTR-815DC-SPR Inbuilding RF Repeater User Manual Manual
Mirror Download [FCC.gov]GS Instech GSTR-815DC-SPR Inbuilding RF Repeater User Manual Manual
Document ID801682
Application IDEupJDXvecLkH5lJBZqmSgA==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize137.11kB (1713847 bits)
Date Submitted2007-06-08 00:00:00
Date Available2007-07-23 00:00:00
Creation Date2007-05-29 19:09:53
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2007-05-29 19:09:53
Document TitleMicrosoft Word - Manual.doc
Document CreatorPScript5.dll Version 5.2
Document Author: Siegfreid

FCC ID : U88GSTR-815DC-SPR
ATTACHMENT E.
- USER MANUAL -
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
1/23
FCC ID : U88GSTR-815DC-SPR
- INDEX 1. SUMMARY................................................................................................................ 3
2. SYSTEM STRUCTURE .............................................................................................. 4
2.1 Network structure for iDEN 15dBm RF Repeater............................................................................................. 4
2.2 System Design and Operation.............................................................................................................................. 5
3. SPECIFICATIONS ................................................................................................. 10
3.1 System specifications .......................................................................................................................................... 10
3.2 Electrical and Environment Specifications........................................................................................................11
3.3 Functions ..............................................................................................................................................................11
4. SET UP ................................................................................................................... 13
4.1 System Set up ...................................................................................................................................................... 13
4.2 Troubleshooting................................................................................................................................................... 16
c. When in trouble shooting, technician should use attenuator to check output side.......................................... 16
5. WEB USER INTERFACE ...................................................................................... 17
5.2 Web UI ................................................................................................................................................................. 18
5.3 Web UI control .................................................................................................................................................... 19
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
2/23
FCC ID : U88GSTR-815DC-SPR
1. SUMMARY
iDEN repeater is located in blanket / shadow area of insider of building to transmit iDEN800MHz,
iDEN900MHz BTS signal simultaneously.
There are two types of RF Repeater for iDEN band as each 15dBm, and 25dBm output power in system
65dB Gain, and 15dBm output power in system 80dB Gain.
This User Manual is the Repeater having 65dBGain / +15dBm output power.
Bandwidth
Downlink 851MHz~869MHz, Uplink 806MHz~824MHz (18MHz Band)
Downlink 862MHz~869MHz, Uplink 817MHz~824MHz (7MHz Band)
To avoid paging signal interference at 940MHz side, IF Converter shift SAW filter edge by 200KHz, 400KHz.
(TX Edge only, not whole bandwidth).
Also, This Repeater is equipped for Output power control by AGC/ALC, Gain Control by Attenuator
adjustment, Remote Control by using Web UI and Remote Firmware Up-grade.
Abbreviation
PAM: POWER AMPLIFIER MODULE
LNA: LOW NOISE AMPLIFIER
AGC: AUTO GAIN CONTROL
ALC: AUTO LIMIT CONTROL
Ethernet Instruction “ This equipment is indoor use and all the communication wirings
are limited to inside of the building” or similar texts.
For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the
equipment and shall be easily accessible.
Replaceable batteries instruction
CAUTION
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECTIVE TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS
2.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
3/23
FCC ID : U88GSTR-815DC-SPR
2. SYSTEM STRUCTURE
2.1 Network structure for iDEN 15dBm RF Repeater
Below picture shows a Network structure for iDEN In-building RF Repeater in a real site. Donor ANT takes a
position on the direction to BTS which be linked, and Server ANT is available to be located in designated
area for service by using RF cable deployments and dividers as blow.
One thing that we consider is Path losses between Repeater port and ANT in case of dividing by dividers and
RF cables. They should be equally managed.
 iDEN In-building Repeater Service Organization
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
4/23
FCC ID : U88GSTR-815DC-SPR
2.2 System Design and Operation
2.2.1 System design
NO.
①
②
③
④
⑤
PART
NO.
PART
MODEM
⑥
WAVE MONITORING
⑦
⑧
⑨
RVS PATH PART
FWD PATH PART
PSU MODULE
SERVICE CAVITY FILTER
DONOR CAVITY FILTER
NMS BOARD
I’O BOARD
 iDEN 15dBm internal design
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
5/23
FCC ID : U88GSTR-815DC-SPR
NO.
①
PORT
SERVICE ANT PORT
NO.
④
PART
DC POWER PORT
②
③
DONOR ANT PORT
AC POWER PORT
⑤
⑥
MONITOR PORT
ETHERNET PORT
 iDEN 15dBm PORT design
2.2.2 Downlink Path
There are four (4) parts of downlink Block in iDEN In-building RF Repeater.
Filter part for Multiplex four (4) bands as each 800MHz and 900MHz TX/RX
in Front End of
Donor/Server
LNA part of Donor/Service path to process signals of 800MHz and 900MHz bands.
If Converter part having several bands of SAW Filter paths to adjust Band Edge of high frequency as
200KHz and 400KHz each. In case of 800MHz band, extra Switching Filters equipped to individually
select 18MHz and 7MHz
Power Amplifier part for power amplifier and Level Monitoring/VSWR monitoring to adjust desirable
output power of Repeater
Downlink frequency contains lots of signals such as Paging signal, DCS etc through Donor ANT. So Out band
signals should be minimized by SAW filters having excellent Roll off characteristics for the best optimized
operation.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
6/23
FCC ID : U88GSTR-815DC-SPR
 iDEN In-building RF Repeater Downlink Block Diagram
2.2.3 Uplink Path
Uplink Block of iDEN In-building RF Repeater is separated as four (4) parts.
Filter part for Multiplex four (4) bands as each 800MHz and 900MHz TX/RX
in Front End of
Donor/Server
LNA Part of two(2) paths for processing 800MHz and 900MHz signals
800MHz IF Converter part and 900MHz IF Converter part of 5MHz band having Switching filter parts
for selecting each 18MHz and 7MHz.
Power Amplifier part for power amplifier and Level Monitoring/VSWR monitoring to adjust desirable
output power of Repeater
800MHz IF Converter part is designed to select single path, and it can be minimizing signal interference
between paths, and power consumption according to controls of electric power in each SAW Filter part.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
7/23
FCC ID : U88GSTR-815DC-SPR
 iDEN In-building RF Repeater Uplink Block Diagram
2.2.4 Adjustable Band Edge functional circuit configuration
In case of IDEN using the bandwidth of 800MHz and 900MHz, many of Out of Band Signals is input via
Donor ANT Outdoor. The most worried signal among them is Paging Signal. Commercial Paging Signal of
929MHz~932MHz, 940MHz~941MHz, having the strength of Max. -15dBm, is to be inputted into Donor ANT.
Among this two kind of Paging Signal Band, 929MHz~932MHz bandwidth is possible for sufficient Rejection
via SAW Filter, But 940MHz~941MHz is difficult to gain big decreasing volume even if use SAW Filter
because Band Edge is as close as to be folded to 935MHz~940MHz of being the frequency of iDEN900MHz
Downlink.
To prepare for this environment, Down Link of iDEN Repeater is designed to have additional Roll Off
characteristic by decreasing band of SAW Filter in the station adjacent to paging signal, for it having the
function of Adjust Band Edge that can decrease c of high frequency by 200 kHz, 400 kHz each.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
8/23
FCC ID : U88GSTR-815DC-SPR
 Additional Roll off through Adjust Band Edge
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
9/23
FCC ID : U88GSTR-815DC-SPR
3. SPECIFICATIONS
3.1 System specifications
Specification
Characteristic
800MHz
Forward
Frequency Range
900MHz
800MHz
Reverse
900MHz
18 MHz BAND
851~869 MHz
17.8 MHz BAND
851~868.8 MHz
17.6 MHz BAND
851~868.6MHz
7 MHz BAND
862~869 MHz
6.8 MHz BAND
862~868.8 MHz
6.6 MHz BAND
862~868.6MHz
5 MHz BAND
935~940MHz
4.8 MHz BAND
935~939.8MHz
4.6 MHz BAND
935~939.6MHz
18 MHz BAND
806~824 MHz
7 MHz BAND
817~824 MHz
5 MHz BAND
896~901 MHz
System Group Delay
<8㎲
Characteristic Impedance
50 ohm
VSWR
Max.1.5 : 1
Input Power Range
-53 ~ -28dBm (FWD, RVS common)
Gain Range
40dB ~ 65dB
< 5 dB @ Max Gain
Noise Figure
<12 dB @Min Gain
Gain Adjustment Step(Accuracy)
1dB(±0.5dB)
Pass Band Ripple
2.5dB(±1.25dB)
Maximum Output Power
31.6mW / 15dBm @ Composite Power
800MHz:12dBm, 900 MHz:12dBm
Spurious Emissions
<-13dBm
IF Frequency
FWD: 70 MHz, RVS: 70 MHz
Adjacent
Channel
Power
@CH
offset
25 KHz
@CH
offset
50 KHz
@CH
offset
500 KHz
> 50 dBm
@ Degradation of 3dB for eight iDEN carriers
> 55 dBm
@ Degradation of 3dB for eight iDEN carriers
> 55 dBm
@ Degradation of 3dB for eight iDEN carriers
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
10/23
FCC ID : U88GSTR-815DC-SPR
@CH
offset
1MHz
@CH
offset
2 MHz
> 55 dBm
@ Degradation of 3dB for eight iDEN carriers
> 55 dBm
@ Degradation of 3dB for eight iDEN carriers
Adjust
@ 869 MHz
868.8MHz/868.6MHz
Band Edge
@ 940 MHz
939.8MHz/939.6MHz
Band Select
Local Shift & RF Switching
Roll Offs
> 50dBc
3.2 Electrical and Environment Specifications
Items
specification
Size(mm) / Type
13(W)*18(L)*4.3(H) / Inch
Power
AC 120V 60Hz 1.4A
Temperature / Weight
0℃ ~ +50℃/16.7kg
Connector TYPE
N Type Female
3.3 Functions
Parameter
Gain Control
AGC
Auto Gain Control
ALC
Auto Limit Control
Band Select
Band Edge Adjust
Power Monitoring
Function
Specification
• Adjustable DL and UL Gain range 40~65dB
• Display default Gain and current Gain function
• It always operates in Downlink AGC ON status
• To maintain same Downlink output power despite flexible input signal
strength.
• To add or subtract Attenuation level referring to AGC Power Limit level.
• To limit output power as far as default range
• Set up via GUI
• Automatic Gain decrement when output power of repeater is higher than
default level
• Automatic Gain recovery when output power of repeater is reduced.
• Shutdown when output power is higher than default level in Minimum Gain
• Automatic Recovery Algorithm conversion after Shutdown status
• In case of 800MHz FWD Band, it enables User to select one of 18MHz,
17.8MHz, 17.6MHz/ 7MHz, 6.8MHz, and 6.6MHz according to GUI setting.
• In case of 900MHz FWD Band, it enables User to select one of 5MHz,
4.8MHz, 4.6MHz according to GUI setting.
• In case of 800MHz RVS Band, it enables User to select one of 18MHz/
7MHz according to GUI setting.
• In case of 900MHz RVS Band, it enables User to select 5MHz according to
GUI setting.
• To shift Band edge of DL high frequency side by 200kHz, 400kHz step
• Monitoring repeater’s output level
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
11/23
FCC ID : U88GSTR-815DC-SPR
Oscillation Check
DL Input control
Automatic Recovery
Security
Temperature
control
VSWR Monitoring
IP address report
via E-mail
DHCP Client
DHCP Server
Web GUI
SNMP Agent
LED Display
• Isolation Check in initial set up or Reset
• Monitoring Oscillation comparing to minimum/maximum Noise Floor level
• When Oscillation occurred, repeater attempts to stabilize Isolation through
Gain control function.
• Shutdown repeater when Oscillation still goes in Minimum Gain
• Automatic Recovery Algorithm conversion after Shutdown status
• Monitoring Donor ANT input power of DL
• When in repeater shutdown, it periodically recovers output power of
repeater then monitors alarming
• Support HTTPS for Web Browser security
• User authentication through User ID and Password
• Monitoring temperature of repeater
• Maximum and minimum set up is possible. Shutdown in over temperature
• Automatic recovery after temperature becomes normal. (Hysteresis
10degree)
• Monitoring VSWR of Donor ANT Port (Every one and half minute)
• Reporting VSWR Alarm and Shutdown when the rate is 3:1
• Automatic Recovery Algorithm conversion after Shutdown status
• When in PPP reconnection, E-mail which includes HTML to connect to
newly assigned IP Address, reports to operator.
• Automatic IP assignment
• Server function for automatic IP assignment
• Remote and local user browser support through Web Browser
• NMS report via SNMPv2 Trap
• LED displays power and operation status on front side of repeater system.
• DL input and output signal level is verified by LED bar.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
12/23
FCC ID : U88GSTR-815DC-SPR
4. SET UP
4.1 System Set up
4.1.1 Constitution (based on 1 SET)
Parameter
Item
Major accessory
iDEN 15dBm repeater
Additional components
Main power input Cable
Mountable Bracket
Fixable Screw
Manual
User Manual
Quantity
1 EA
EA
EA
SET
EA
4.1.2 Notice
1 ) System Power check : Major electricity is A C 1 2 0 V, therefore please input electricity after power
verification.
 MS 3100 A 10SL-3 (Wall Mount Receptacle) & MS3010 A 10SL-3(Plug)
2) Input condition optimization: DL input condition of iDEN is -53 ~ -28dBm.
3) Isolation check between DONOR/SERVICE ANT: Isolation condition of this equipment is 95dBc (Gain+
15dB). User should check its condition before installation.
4) This equipment is basically wall mountable installation.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
13/23
FCC ID : U88GSTR-815DC-SPR
 Wall mounted iDEN In-building RF Repeater
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
14/23
FCC ID : U88GSTR-815DC-SPR
 Hole sizes of iDEN In-building RF Repeater
4.1.3 System set up
1) Once aforementioned process is done, open for service get ready.
2) For grounding, there is a grounding terminal in main power supply side and the grounding
terminal on a site and unit should be connected same.
3 ) System installation work is basically performed more than two people and should be careful for
unexpected accident.
4.1.4
Open for service
1) Check points before open
a. Verification of system installation status
Electricity, In/out antenna, coaxial cable connection, equipment mounts status.
b. Verification of system accessories
User should check whole necessary accessories.
c. Check receipt signal level
User should check whether receipt environmental condition is in accordance with system specification, so
that system operation will be optimized.
2) Check points after open
a. Check by external LED
① RUN: Green light ON (Off: Green light off)
② ALARM: Green light in normal status, Red light in alarming
③ SHUT DOWN: Green light in normal status, Red light in Shutdown
④ iDEN
Number of LED bar on front side of repeater will show input signal level.
-58 dBm~ -48dBm: LED 1bar
-47dBm~-43dBm: LED 2 bars
-42dBm~-38dBm: LED 3 bars
-37dBm~-33dBm: LED 4 bars
Up than -32dBm: LED 5 bars
Number of LED bar in output power side will show output power signal level.
-10dBm~-6dBm: LED 1bar
-5dBm~-1dBm: LED 2bars
+0dBm~+4dBm: LED 3bars
+5dBm~+9dBm: LED 4bars
Up than +10dBm: LED 5bars
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
15/23
FCC ID : U88GSTR-815DC-SPR
 iDEN In-building RF Repeater front LED
b. Verification via Debug Program
User should check operation status of repeater system via Debug Program.
c. Verification of operation status
Use should verify following status with Output monitoring terminal, which is provided by
Spectrum Analyzer.
- Output power generation status, system spurious emission characteristics.
d. Verification of signal quality and strength in service area
User should verify signal strength and quality of in-service coverage area by using cell phone or other
terminal.
e. Verification of upper-level NMS operation status
4.2 Troubleshooting
In case, abnormal operation is detected, user should check abnormal parts via remote accessible
function or field debug, then conduct repair after turn it off.
4.2.1 Necessary Testing and Measuring equipment
a. RF Power Meter: 10Watt Max, 50ohm
b. Signal Generator: 3GHz
c. Spectrum Analyzer: 3GHz
d. Multi Meter
4.2.2 Notice
a. Trouble shooting should be performed with drastic knowledge basis.
b. Unsure parts should not be disassembled.
c. When in trouble shooting, technician should use attenuator to check output side.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
16/23
FCC ID : U88GSTR-815DC-SPR
5. WEB USER INTERFACE
5.1 IP Address verification and Explorer setting
5.1.1 IP Address verification
(1)
(2)
(3)
(4)
Start->Control Panel->Network Connections
Double-click Local Area Connections at LAN or High Speed internet
Click Internet Protocol (TCP/IP) at General tap and click Properties.
Apply automatic IP address assignment at local connection
(5) Verify assigned IP address at local connection.
(Unless IP address is not assigned, please click
repair.)
5.1.2 Explorer option setting
- Proceed step by step as indicated in below. All files and
records should be removed.
- Set up mode will be displayed after (2) click.
- Please proceed along following set up mode screen
shot.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
17/23
FCC ID : U88GSTR-815DC-SPR
5.2 Web UI
5.2.1 Web UI connection
- Input desirable IP address.
- Default Use Name and Password for Web UI is ‘admin’.
5.2.2 Link menu
- Following screen shot is located left-top side of main menu and those are linked to relative window.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
18/23
FCC ID : U88GSTR-815DC-SPR
5.3 Web UI control
5.3.1 Status
- Currently setting level check at this menu tap.
5.3.2 RF Configuration
- Setting level can be changed at this menu tap.
- (1) Level change
- (2) Click Apply button
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
19/23
FCC ID : U88GSTR-815DC-SPR
5.3.3 Alarm Configuration
- (1) On/Off function for entire alarm report
- (2) Alarm status
- (3) On/Off function for individual alarm category
- (4) Alarm SNMP Mapping
- User may set and change its level per it field condition and click apply button.
5.3.4 Communication Configuration
- This provides all necessary information related to network
- To provide relative information about DHCP and modem
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
20/23
FCC ID : U88GSTR-815DC-SPR
5.3.5 User Management
- Add and Remove user, Assigning accessibility
- (1) User Registration: Click Register after input required information
- (2) User Removal: Click Delete upon click of user name you wish to remove.
- (3) Super User: Accessible to all kinds of information path
Read/Write: Accessible to all kinds of information path except for User management path.
Read: Checking status only. No control
5.3.6 Logs
- All users’ access record will be saved as a log.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
21/23
FCC ID : U88GSTR-815DC-SPR
5.3.7 Sub System/Mailing List
- Set up e-mail address the place you wish to receive alarm.
5.3.8. Troubleshooting
Following is a trouble shooting table, which is frequently occurred to repeater and treatment method.
5.3.9 Remote Software Upgrade
- Upload repeater operation program.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
22/23
FCC ID : U88GSTR-815DC-SPR
5.3.10 System Reset
- Reset repeater.
HYUNDAI CALIBRATION & CERTIFICATION TECHNOLOGIES CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517
FAX:+82 31 639 8525
www.hct.co.kr
Report No. :
HCT-R07-008
23/23

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2007:05:29 19:09:53+09:00
Create Date                     : 2007:05:29 19:09:53+09:00
Format                          : application/pdf
Title                           : Microsoft Word - Manual.doc
Creator                         : Siegfreid
Document ID                     : uuid:1ef5fa4d-ac18-4a04-958d-bcec5dae605c
Instance ID                     : uuid:88c3172b-f34e-40bc-9940-e8da03b65498
Page Count                      : 23
Author                          : Siegfreid
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U88GSTR-815DC-SPR

Navigation menu