GS Instech GSTR-825DC-SPR iDEN In-Buidling RF Repeater User Manual ATT E
GS Instruments Co., Ltd. iDEN In-Buidling RF Repeater ATT E
User Manual
FCC ID : U88GSTR-825DC-SPR ATTACHMENT E. - USER MANUAL - 1/26 FCC ID : U88GSTR-825DC-SPR INFORMATION TO USER : NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. CAUTION Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user's authority to operate the equipment 2/26 FCC ID : U88GSTR-825DC-SPR - INDEX 1. SUMMARY .................................................................................................................4 2. SYSTEM STRUCTURE...............................................................................................5 2.1 Network structure for iDEN 25dBm RF Repeater ............................................................................................. 5 2.2 System Design and Operation .............................................................................................................................. 6 3. SPECIFICATIONS................................................................................................... 11 3.1 System specifications........................................................................................................................................... 11 3.2 Electrical and Environment Specifications ....................................................................................................... 12 3.3 Functions.............................................................................................................................................................. 12 4. SET UP .....................................................................................................................15 4.1 System Set up....................................................................................................................................................... 15 4.2 Troubleshooting................................................................................................................................................... 19 c. When in trouble shooting, technician should use attenuator to check output side. ......................................... 19 5. WEB USER INTERFACE .........................................................................................19 5.1 IP Address verification and Explorer setting .................................................................................................... 19 5.2 Web UI ................................................................................................................................................................. 21 5.3 Web UI control .................................................................................................................................................... 22 3/26 FCC ID : U88GSTR-825DC-SPR 1. SUMMARY iDEN repeater is located in blanket / shadow area of insider of building to transmit iDEN800MHz, iDEN900MHz BTS signal simultaneously. There are two types of RF Repeater for iDEN band as each 15dBm, and 25dBm output power in system 65dB Gain, and 30dBm output power in system 80dB Gain. This User Manual is the Repeater having 65dBGain / +25dBm output power. Bandwidth Downlink 851MHz~869MHz, Uplink 806MHz~824MHz (18MHz Band) Downlink 862MHz~869MHz, Uplink 817MHz~824MHz (7MHz Band) To avoid paging signal interference at 940MHz side, IF Converter shift SAW filter edge by 200KHz, 400KHz. (TX Edge only, not whole bandwidth). Also, This Repeater is equipped for Output power control by AGC/ALC, Gain Control by Attenuator adjustment, Remote Control by using Web UI and Remote Firmware Up-grade. Abbreviation PAM: POWER AMPLIFIER MODULE LNA: LOW NOISE AMPLIFIER AGC: AUTO GAIN CONTROL ALC: AUTO LIMIT CONTROL 4/26 FCC ID : U88GSTR-825DC-SPR 2. SYSTEM STRUCTURE 2.1 Network structure for iDEN 25dBm RF Repeater Below picture shows a Network structure for iDEN In-building RF Repeater in a real site. Donor ANT takes a position on the direction to BTS which be linked, and Server ANT is available to be located in designated area for service by using RF cable deployments and dividers as blow. One thing that we consider is Path losses between Repeater port and ANT in case of dividing by dividers and RF cables. They should be equally managed.iDEN In-building Repeater Service Organization 5/26 FCC ID : U88GSTR-825DC-SPR 2.2 System Design and Operation 2.2.1 System design NO. PART NO. PART ① MODEM MODULE ⑦ RVS LAN MODULE ② CAVITY FILTER MODULE ⑧ FWD LAN MODULE ③ PSU MODULE ⑨ I’O BOARD MODULE ④ 7M IF CONVERTER MODULE ⑩ POWER AMPLIFIER MODULE ⑤ 18M IF CONVERTER MODULE ⑪ WAVE MONITORING MODULE ⑥ 5M IF CONVERTER MODULE ⑫ NMS MODULE 6/26 FCC ID : U88GSTR-825DC-SPR iDEN 25dBm internal design NO. PORT NO. PORT ① SERVICE ANT PORT ⑤ AC POWER PORT ② SERVICE ANT TERM ⑥ DC POWER PORT ③ DONOR ANT PORT ⑦ MONITOR PORT ④ DONOR ANT TERM ⑧ ETHERNET PORT iDEN 25dBm PORT design 2.2.2 Downlink Path There are four (4) parts of downlink Block in iDEN In-building RF Repeater. Filter part for Multiplex four (4) bands as each 800MHz and 900MHz TX/RX in Front End of Donor/Server LNA part of Donor/Service path to process signals of 800MHz and 900MHz bands. 7/26 FCC ID : U88GSTR-825DC-SPR If Converter part having several bands of SAW Filter paths to adjust Band Edge of high frequency as 200KHz and 400KHz each. In case of 800MHz band, extra Switching Filters equipped to individually select 18MHz and 7MHz Power Amplifier part for power amplifier and Level Monitoring/VSWR monitoring to adjust desirable output power of Repeater Downlink frequency contains lots of signals such as Paging signal, DCS etc through Donor ANT. So Out band signals should be minimized by SAW filters having excellent Roll off characteristics for the best optimized operation. iDEN In-building RF Repeater Downlink Block Diagram 2.2.3 Uplink Path Uplink Block of iDEN In-building RF Repeater is separated as four (4) parts. Filter part for Multiplex four (4) bands as each 800MHz and 900MHz TX/RX in Front End 8/26 FCC ID : U88GSTR-825DC-SPR of Donor/Server LNA Part of two(2) paths for processing 800MHz and 900MHz signals 800MHz IF Converter part and 900MHz IF Converter part of 5MHz band having Switching filter parts for selecting each 18MHz and 7MHz. Power Amplifier part for power amplifier and Level Monitoring/VSWR monitoring to adjust desirable output power of Repeater 800MHz IF Converter part is designed to select single path, and it can be minimizing signal interference between paths, and power consumption according to controls of electric power in each SAW Filter part. iDEN In-building RF Repeater Uplink Block Diagram 2.2.4 Adjustable Band Edge functional circuit configuration In case of IDEN using the bandwidth of 800MHz and 900MHz, many of Out of Band Signals is input via Donor ANT Outdoor. The most worried signal among them is Paging Signal. 9/26 FCC ID : U88GSTR-825DC-SPR Commercial Paging Signal of 929MHz~932MHz, 940MHz~941MHz, having the strength of Max. -15dBm, is to be inputted into Donor ANT. Among this two kind of Paging Signal Band, 929MHz~932MHz bandwidth is possible for sufficient Rejection via SAW Filter, But 940MHz~941MHz is difficult to gain big decreasing volume even if use SAW Filter because Band Edge is as close as to be folded to 935MHz~940MHz of being the frequency of iDEN900MHz Downlink. To prepare for this environment, Down Link of iDEN Repeater is designed to have additional Roll Off characteristic by decreasing band of SAW Filter in the station adjacent to paging signal, for it having the function of Adjust Band Edge that can decrease c of high frequency by 200 kHz, 400 kHz each. Additional Roll off through Adjust Band Edge 10/26 FCC ID : U88GSTR-825DC-SPR 3. SPECIFICATIONS 3.1 System specifications Characteristic Specification 800MHz Forward Frequency Range 900MHz Reverse 800MHz 900MHz 18 MHz BAND 851~869 MHz 17.8 MHz BAND 851~868.8 MHz 17.6 MHz BAND 851~868.6MHz 7 MHz BAND 862~869 MHz 6.8 MHz BAND 862~868.8 MHz 6.6 MHz BAND 862~868.6MHz 5 MHz BAND 935~940MHz 4.8 MHz BAND 935~939.8MHz 4.6 MHz BAND 935~939.6MHz 18 MHz BAND 806~824 MHz 7 MHz BAND 817~824 MHz 5 MHz BAND 896~901 MHz System Group Delay < 8㎲ Characteristic Impedance 50 ohm VSWR Max.1.5 : 1 Input Power Range -43 ~ -18dBm (FWD, RVS common) Gain Range 40dB ~ 65 dB < 5 dB @ Max Gain Noise Figure <12 dB @Min Gain Gain Adjustment Step(Accuracy) 1dB(±0.5dB) 11/26 FCC ID : U88GSTR-825DC-SPR Pass Band Ripple 2.5dB(±1.25dB) Maximum Output Power 316.2mW / 25dBm @ Composite Power 800MHz:22dBm, 900 MHz:22dBm Spurious Emissions <-13dBm IF Frequency FWD: 70 MHz, RVS: 70 MHz @CH offset 25 KHz @CH offset 50 KHz Adjacent @CH Channel offset 500 KHz Power @CH offset 1MHz @CH offset 2 MHz > 50 dBm @ Degradation of 3dB for eight iDEN carriers > 55 dBm @ Degradation of 3dB for eight iDEN carriers > 55 dBm @ Degradation of 3dB for eight iDEN carriers > 55 dBm @ Degradation of 3dB for eight iDEN carriers > 55 dBm @ Degradation of 3dB for eight iDEN carriers Adjust @ 869 MHz 868.8MHz/868.6MHz Band Edge @ 940 MHz 939.8MHz/939.6MHz Band Select Local Shift & RF Switching Roll Offs > 50dBc 3.2 Electrical and Environment Specifications Items specification Size(mm) / Type 16(W)*18(L)*7(H) / Inch Power AC 120V 60Hz 3.0A Temperature / Weight Connector TYPE 0℃ ~ +50℃/20.6kg N Type Female 3.3 Functions Parameter Gain Control AGC Auto Gain Control Specification • Adjustable DL and UL Gain range 40~65dB • Display default Gain and current Gain function • It always operates in Downlink AGC ON status • To maintain same Downlink output power despite flexible input signal strength. 12/26 FCC ID : U88GSTR-825DC-SPR • To add or subtract Attenuation level referring to AGC Power Limit level. • To limit output power as far as default range • Set up via GUI ALC Auto Limit Control • Automatic Gain decrement when output power of repeater is higher than default level • Automatic Gain recovery when output power of repeater is reduced. • Shutdown when output power is higher than default level in Minimum Gain • Automatic Recovery Algorithm conversion after Shutdown status • In case of 800MHz FWD Band, it enables User to select one of 18MHz, 17.8MHz, 17.6MHz/ 7MHz, 6.8MHz, and 6.6MHz according to GUI setting. • In case of 900MHz FWD Band, it enables User to select one of 5MHz, Band Select 4.8MHz, 4.6MHz according to GUI setting. • In case of 800MHz RVS Band, it enables User to select one of 18MHz/ 7MHz according to GUI setting. • In case of 900MHz RVS Band, it enables User to select 5MHz according to GUI setting. Band Edge Adjust Power Monitoring Function • To shift Band edge of DL high frequency side by 200kHz, 400kHz step • Monitoring repeater’s output level • Isolation Check in initial set up or Reset • Monitoring Oscillation comparing to minimum/maximum Noise Floor level Oscillation Check • When Oscillation occurred, repeater attempts to stabilize Isolation through Gain control function. • Shutdown repeater when Oscillation still goes in Minimum Gain • Automatic Recovery Algorithm conversion after Shutdown status DL Input control Automatic Recovery Security • Monitoring Donor ANT input power of DL • When in repeater shutdown, it periodically recovers output power of repeater then monitors alarming • Support HTTPS for Web Browser security • User authentication through User ID and Password • Monitoring temperature of repeater Temperature • Maximum and minimum set up is possible. Shutdown in over temperature control • Automatic recovery after temperature becomes normal. (Hysteresis 10degree) VSWR Monitoring • Monitoring VSWR of Donor ANT Port (Every one and half minute) 13/26 FCC ID : U88GSTR-825DC-SPR • Reporting VSWR Alarm and Shutdown when the rate is 3:1 • Automatic Recovery Algorithm conversion after Shutdown status IP address report via E-mail • When in PPP reconnection, E-mail which includes HTML to connect to newly assigned IP Address, reports to operator. DHCP Client • Automatic IP assignment DHCP Server • Server function for automatic IP assignment Web GUI SNMP Agent LED Display • Remote and local user browser support through Web Browser • NMS report via SNMPv2 Trap • LED displays power and operation status on front side of repeater system. • DL input and output signal level is verified by LED bar. 14/26 FCC ID : U88GSTR-825DC-SPR 4. SET UP 4.1 System Set up 4.1.1 Constitution (based on 1 SET) Parameter Item Quantity Major accessory iDEN 25dBm repeater 1 EA Additional components Main power input Cable 1 EA Mountable Bracket 1 EA Fixable Screw 1 SET Manual 1 EA User Manual 4.1.2 Notice 1 ) System Power check : Major electricity is A C 1 1 0 V, therefore please input electricity after power verification. MS 3100 A 10SL-3 (Wall Mount Receptacle) & MS3010 A 10SL-3(Plug) 2) Input condition optimization: DL input condition of iDEN is -43 ~ -18dBm. 3) Isolation check between DONOR/SERVICE ANT: Isolation condition of this equipment is 80dBc (Gain+ 15dB) in iDEN. User should check its condition before installation. 4) This equipment is basically wall mountable installation. 15/26 FCC ID : U88GSTR-825DC-SPR Wall mounted iDEN In-building RF Repeater 16/26 FCC ID : U88GSTR-825DC-SPR Hole sizes of iDEN In-building RF Repeater 4.1.3 System set up 1) Once aforementioned process is done, open for service get ready. 2) For grounding, there is a grounding terminal in main power supply side and the grounding terminal on a site and unit should be connected same. 3) System installation work is basically performed more than two people and should be careful for unexpected accident. 4.1.4 Open for service 1) Check points before open a. Verification of system installation status Electricity, In/out antenna, coaxial cable connection, equipment mounts status. b. Verification of system accessories User should check whole necessary accessories. c. Check receipt signal level User should check whether receipt environmental condition is in accordance with system specification, so that system operation will be optimized. 2) Check points after open 17/26 FCC ID : U88GSTR-825DC-SPR a. Check by external LED ① RUN: Green light ON (Off: Green light off) ② ALARM: Green light in normal status, Red light in alarming ③ SHUT DOWN: Green light in normal status, Red light in Shutdown ④ iDEN Number of LED bar on front side of repeater will show input signal level. -43 dBm~38dBm: LED 1bar -37dBm~-33dBm: LED 2 bars -32dBm~-28dBm: LED 3 bars -27dBm~-23dBm: LED 4 bars Up than -22dBm: LED 5 bars Number of LED bar in output power side will show output power signal level. +0dBm~+4dBm: LED 1bar +5dBm~+9dBm: LED 2bars +10dBm~+14dBm: LED 3bars +15dBm~+19dBm: LED 4bars Up than +20dBm: LED 5bars iDEN In-building RF Repeater front LED b. Verification via Debug Program User should check operation status of repeater system via Debug Program. c. Verification of operation status Use should verify following status with Output monitoring terminal, which is provided by 18/26 FCC ID : U88GSTR-825DC-SPR Spectrum Analyzer. - Output power generation status, system spurious emission characteristics. d. Verification of signal quality and strength in service area User should verify signal strength and quality of in-service coverage area by using cell phone or other terminal. e. Verification of upper-level NMS operation status 4.2 Troubleshooting In case, abnormal operation is detected, user should check abnormal parts via remote accessible function or field debug, then conduct repair after turn it off. 4.2.1 Necessary Testing and Measuring equipment a. RF Power Meter: 10Watt Max, 50ohm b. Signal Generator: 3GHz c. Spectrum Analyzer: 3GHz d. Multi Meter 4.2.2 Notice a. Trouble shooting should be performed with drastic knowledge basis. b. Unsure parts should not be disassembled. c. When in trouble shooting, technician should use attenuator to check output side 5. WEB USER INTERFACE 5.1 IP Address verification and Explorer setting 5.1.1 IP Address verification (1) Start->Control Panel->Network Connections (2) Double-click Local Area Connections at LAN or High Speed internet (3) Click Internet Protocol (TCP/IP) at General tap and click Properties. (4) Apply automatic IP address assignment at local connection 19/26 FCC ID : U88GSTR-825DC-SPR (5) Verify assigned IP address at local connection. (Unless IP address is not assigned, please click repair.) 5.1.2 Explorer option setting - Proceed step by step as indicated in below. All files and records should be removed. - Set up mode will be displayed after (2) click. - Please proceed along following set up mode screen shot. 20/26 FCC ID : U88GSTR-825DC-SPR 5.2 Web UI 5.2.1 Web UI connection - Input desirable IP address. - Default Use Name and Password for Web UI is ‘admin’. 5.2.2 Link menu - Following screen shot is located left-top side of main menu and those are linked to relative 21/26 FCC ID : U88GSTR-825DC-SPR window. 5.3 Web UI control 5.3.1 Status - Currently setting level check at this menu tap. 5.3.2 RF Configuration - Setting level can be changed at this menu tap. - (1) Level change - (2) Click Apply button 22/26 FCC ID : U88GSTR-825DC-SPR 5.3.3 Alarm Configuration - (1) On/Off function for entire alarm report - (2) Alarm status - (3) On/Off function for individual alarm category - (4) Alarm SNMP Mapping - User may set and change its level per it field condition and click apply button. 5.3.4 Communication Configuration 23/26 FCC ID : U88GSTR-825DC-SPR - This provides all necessary information related to network - To provide relative information about DHCP and modem 5.3.5 User Management - Add and Remove user, Assigning accessibility - (1) User Registration: Click Register after input required information - (2) User Removal: Click Delete upon click of user name you wish to remove. - (3) Super User: Accessible to all kinds of information path Read/Write: Accessible to all kinds of information path except for User management path. Read: Checking status only. No control 24/26 FCC ID : U88GSTR-825DC-SPR 5.3.6 Logs - All users’ access record will be saved as a log. 5.3.7 Sub System/Mailing List - Set up e-mail address the place you wish to receive alarm. 5.3.8. Troubleshooting Following is a trouble shooting table, which is frequently occurred to repeater and treatment me thod. 25/26 FCC ID : U88GSTR-825DC-SPR 5.3.9 Remote Software Upgrade Upload repeater operation program. 5.3.10 System Reset - Reset repeater. 26/26
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2007:06:18 17:39:57+09:00 Create Date : 2007:06:18 17:39:57+09:00 Format : application/pdf Title : Microsoft Word - ATT.E User Manual.doc Creator :EXIF Metadata provided by EXIF.toolsDocument ID : uuid:799202ed-9da2-422a-ae3d-27d2d7414c39 Instance ID : uuid:2df61263-4b95-428b-b4bb-53dae8bdf9f5 Page Count : 26 Author :