Gallagher Group C1977X0 Cardax Prox Plus Reader (Mifare) User Manual
Gallagher Group Ltd Cardax Prox Plus Reader (Mifare) Users Manual
Users Manual
Installation Note Cardax Prox Plus Mifare Reader CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any servicing. Before you begin Unpack the Prox Plus Mifare reader and check that you received the following items: 1 x Base plate 1 x Reader assembly 1 x Interconnect board 1 x Four-pin Molex 6471 crimp-terminal socket equipped with grommet and 400 mm flexible cord Part number 3C4480 R10 May 2005 4 x Self-tapping pan-head screws 4 x 10 mm plastics screw caps 1 x M4 x 12 tamper-resistant Torx-head machine screw Power supply requirements Each Prox Plus Mifare reader consumes 200 mA from a 13.6 V ± 15% DC supply. Use a linear-regulator power source. Note: Switch mode power supplies are not recommended as they may reduce the read range of the Prox Plus Mifare reader. Firmware The reader firmware has two variants. These are set out in the table. Firmware identification Capability vR1.06 and earlier Reads Philips Mifare 1K cards. vR2.05 and later Reads Philips Mifare 1K cards Reads all sectors of Philips Mifare 4K cards Depending on the type of firmware, there is a difference in the sequence displayed on the reader's screen after power has been applied. Part number 3C4480 R10 May 2005 vR1.nn vR2.nn After power has been applied, the reader: After power has been applied, the reader: Beeps Displays each of its icons in sequence Displays each of its icons in sequence Displays the secure icon . Displays each of its icons in sequence a second time Displays all icons simultaneously Displays a blank screen for about two seconds Displays the secure icon . Beeps The version of firmware used by the reader is shown on a label attached to the central processor integrated circuit. The diagrams below show the location of the label for both variants of the reader. (MFCM 200) (MFRC500) Part number 3C4480 R10 May 2005 Cabling The Prox Plus Mifare reader uses the Cardax IV communications system. It can be connected to the following equipment: Cardax FT Controller 3000 Cardax FT Reader I/O Interface Cardax FT URI Use 4 core, 0.2 mm² (AWG 24) cabling with a maximum nominal capacitance of 120 pF/m. With this type of cable, the maximum distance between the Prox Plus Mifare reader and the device to which it connects is 200 m (650 ft). Distance between proximity readers The distance separating any two proximity readers must not be less than 200 mm in all directions. 200 mm Part number 3C4480 R10 May 2005 When mounting a proximity reader on an internal wall, check that any reader fixed to the other side of the wall is not less than 200 mm away. Attaching the base plate Note: The Prox Plus Mifare reader has been designed to metric specifications. Any imperial measurements shown in this document are approximate. The Prox Plus Mifare reader is designed to be mounted on any solid flat surface including metal surfaces. The recommended mounting height for the Prox Plus Mifare reader is 1100 mm from floor level to the centre of the reader device. However this may vary in some countries and you should check local regulations for variations to this height. Drill a 20 mm (3/4 inch) diameter hole for the base extrusion through or into the mounting surface to a minimum depth of 40 mm (1½ inches). Run the building cabling through the base. Part number 3C4480 R10 May 2005 Press the base extrusion into the 20 mm (3/4 inch) hole and secure the base to the mounting surface using the four fixing screws. Fit the screw caps over each fixing screw. The screw caps prevent water from entering the reader via the fixing holes. The caps must be installed for the Prox Plus Mifare reader to comply with the environmental specification. Note: It is very important that the base of the reader is flush with and tight against the mounting surface. If you are mounting the Prox Plus Mifare reader on a rough surface you should make the surface as smooth as possible under the reader and up to 25 mm (1 inch) around the reader. Note: The grommet through which the cables feed into the base of the Prox Plus Mifare reader helps to keep the device waterproof. Part number 3C4480 R10 May 2005 Connections INTERCONNECT BOARD MOLEX 6471 CRIMP TERMINAL SOCKET 4 3 2 1 4 3 2 1 (VIEWED FROM CABLE SIDE OF SOCKET) (VIEWED FROM CABLE SIDE OF CONNECTOR) RED WHITE BLUE BLACK READER +12V DATA OUT DATA IN FT CONTROLLER 3000; FT READER I/O INTERFACE; OR FT URI -12V INTERCONNECT BOARD (VIEWED FROM READER SIDE OF CONNECTOR) You can connect the building cable to the reader in either of two ways: use the four-pin socket and cord supplied with the reader and join the cord to the building cabling; or provide your own Molex 6471 crimp terminal socket and terminate the building cable directly to it. In either case, ensure that you use the socket grommet supplied with the reader. If you supply your own socket, use the cable terminating tool. The tool has a head (Part No. C861145) and handle (Part No. C861115). Pin number 4 of the socket feeds into the cable terminating tool first. The other end of the building cable connects to one of the following: Cardax FT Controller 3000 Cardax FT Reader I/O Interface Cardax FT URI Part number 3C4480 R10 May 2005 Connecting to the Cardax FT Controller 3000 The Cardax FT Controller 3000 interfaces the following types of reader into the Cardax FT Command Centre system: Cardax IV readers, including Prox Plus Mifare readers Wiegand readers Each Cardax FT Controller 3000 can interface up to eight Prox Plus Mifare readers into the Cardax FT Command Centre system. The ports to which the Prox Plus Mifare reader can connect are set up as four distinct groups (numbered 1 to 4). Each group provides connection for two Prox Plus Mifare readers or other Cardax IV readers. Refer to the following diagram for the location of the ports on the Cardax FT Controller 3000. P3 P4 P1 P4 RS485 P2 J1 to J4 RS485 terminating resistors DETECTOR LED PF4 PF3 PF2 PF1 PE4 PE3 PE2 PE1 PD4 PC4 PD 4 PC4 PD3 PC3 PD3 PC3 PD2 PC2 PD2 PC2 PD1 PC1 PD1 PC1 PC1 to PC4 Inputs pin 1 = Input 1 pin 2 = Ground pin 3 = Input 2 PB4 PA4 Group 4 PA4 POWER OUT PB3 Group 3 PA3 PA3 POWER OUT PB2 Group 2 PA2 PA2 POWER OUT PB1 Group 1 PA1 PA1 POWER OUT PB1 to PB4 2 x Cardax IV Readers per connector PA1 to PA4 Power Out pin 1 = power out pin 2 = 0 V Reader 1 = pins 1 & 3 Reader 2 = pins 2 & 4 Pin Pin Pin Pin 1 = Reader 2 = Reader 3 = Reader 4 = Reader transmit transmit receive receive Make the connections from the Prox Plus Mifare reader to the Cardax FT Controller 3000 as shown: Part number 3C4480 R10 May 2005 Controller 3000 Group (x4) PB1 and PA1... to... PB4 and PA4 PB Prox Plus Mifare Reader 2 PA Prox Plus Mifare Reader 1 Note: Within each group, you cannot mix Cardax IV readers with Wiegand Readers. This is because connecting one Wiegand reader requires all four pins on plug PB. For example, if you connect a Prox Plus Mifare reader to Port 1 of Group 1, Port 2 of Group 1 can only connect to another Cardax IV reader. The terminating resistors (J1 for Group 1, J2 for Group 2, etc.) must NOT be fitted for those groups to which Prox Plus Mifare readers are connected. Connecting to the Cardax FT Reader I/O Interface The Cardax FT Reader I/O Interface has connections for up to sixteen Prox Plus Mifare readers or other Cardax IV readers. The Prox Plus Mifare reader connects to either plug PA or PB in Groups 1 to 8. Make the connections from the Prox Plus Mifare reader to the Reader I/O interface as shown: Part number 3C4480 R10 May 2005 Reader I/O Interface Group (x8) Prox Plus Mifare Readers Red White Blue IN Reader A (PA) OUT Black Red White Blue IN Reader B (PB) OUT Black +V Power (PD) For the location of the plugs on the Reader I/O Interface, refer to the component layout diagram: 10 Part number 3C4480 R10 May 2005 Connecting to the Cardax FT URI Connect the cables to the socket as shown. Cardax FT Universal Reader Interface Prox Plus Mifare Connector Plug P1 or P2 Black GND Blue OUTPUTS White OUTPUTS Red DET COMMS COMMS 5/12V Connect the Prox Plus Mifare reader connector to either the P1 or P2 plug on the Cardax FT URI. Refer to the Cardax FT URI component layout diagram, next, for the location of the plugs. F1 P3 Keypad pin 1 = Row1 pin 2 = Row 2 pin 3 = Row 3 pin 4 = Row 4 pin 5 = Column1 pin 6 = Column2 pin 7 = Column3 pin 8 = Ground P2 Non-CardaxFT Reader 2 pin 1 = 5/12 V power pin 2 = DataA pin 3 = DataB pin 4 = Card detect pin 5 = LED output pin 6 = Beeper output pin 7 = Ground D10 Comms 500mA 13.6 V ± 15%in P6 LED flashing = communicating with FT Controller P5 Power & Comms pins 1 & 2 = RS485 pin 3 = 13.6 V ± 15% pin 4 = 0V 13.6 V ± 15% out pin 1 = 13.6 V ± 15% pin 2 = Ground 3A fused F2 D10 T1 JP1 Reader Voltage select 3A 13.6 V ± 15%out = 12V (1A total) P2 5V JP1 12V D17 NC NO COIL D17 and D21 Relay state indicators LED on = Energised LED off = De-energised COMM NC NO COIL D21 RLY2 COMM D18 (c)1999 PEC(New Zealand) Ltd 10 Reader 1 Part number 3C4480 R10 May 2005 P8 Diagnostic port R1 p1 = Normally closed R1 p2 = Normally open R1 p3 = Common R2 p4 = Normally closed R2 p5 = Normally open R2 p6 = Common p7 = Ground Run LED SW1 REV[A][B][C] 22825V2 Assy 22826 P1 Non-CardaxFT pin 1 = 5/12 V power pin 2 = DataA pin 3 = DataB pin 4 = Card detect pin 5 = LED output pin 6 = Beeper output pin 7 = Ground Relay Outputs D18 P8 P1 P7 SW1 Device address Set device number P4 Balanced Inputs pin 1 = Input1 pin 2 = Input 2 pin 3 = Input 3 pin 4 = Input 4 pin 5 = Input 5 pin 6 = Input 6 pin 7 = Ground 11 Fitting the facia 1. Press the Molex 6471 socket onto the four pin plug on the interconnect board. 2. Push the interconnect board into the base plate so that the Molex 6471 socket beds into the grommet. 3. Push the interconnect board further until it is captured by the clips on the base plate. 4. Slide the facia attachment lugs into the guides at the rear of the base plate. 5. On the front of the facia, press down on the Cardax label until the security screw hole lines up with the M4 threaded hole underneath the base plate. 6. Pass the M4 security screw through the hole in the facia and use a tamper-resistant Torx-head tool to drive it into the threaded hole in the base plate. Removing the facia 1. Using a tamper-resistant Torx-head tool, remove the M4 security screw from the underside of the facia. 2. Pull the base of the facia away from the base plate. 3. Slide the facia's attachment lugs out of the guides at the rear of the base plate. 12 Part number 3C4480 R10 May 2005 Initialisation Initialising with the Cardax FT Controller 3000 Refer to the Cardax FT Controller 3000 Installation Note (Part number 3E1089) for initialisation instructions. Initialisation of the Cardax FT Controller 3000 does not require prior connection to the Prox Plus Mifare reader. The Prox Plus Mifare reader will be operational as soon as it is: connected to a Cardax FT Controller 3000, and configured as a Cardax IV reader within the Cardax FT Command Centre system. Initialising with the Cardax FT Reader I/O Interface Refer to the Cardax FT Reader I/O Interface Installation Note (Gallagher Part number 3E1016) for initialisation instructions. Initialisation of the Cardax FT Reader I/O Interface does not require prior connection to the Prox Plus Mifare reader. The Prox Plus Mifare reader will be operational as soon as it is: connected to a Cardax FT Reader I/O Interface, and configured as a Cardax IV reader within the Cardax FT Command Centre system. Initialising with the Cardax FT URI Refer to the Cardax FT Universal Reader Interface Installation Note (Gallagher Part number 3C4518) for initialisation instructions. Initialisation of the Cardax FT URI does not require prior connection to the Prox Plus Mifare reader. The Prox Plus Mifare reader will be operational as soon as it is: connected to a Cardax FT URI, and configured as a Cardax IV reader within the Cardax FT Command Centre system. Part number 3C4480 R10 May 2005 13 Icons The Prox Plus Mifare reader displays the following icons on the liquid crystal display (LCD) to indicate the access status of the zone controlled by the reader. 14 Part number 3C4480 R10 May 2005 Approvals and Standards This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Note: Changes or modifications not expressly approved by Gallagher Security Management Systems could void the user's authority to operate the equipment. ACN: 002132943 Part number 3C4480 R10 May 2005 15 PUBLISHED BY Gallagher Group Limited Kahikatea Drive, Private Bag 3026 Hamilton, New Zealand Copyright© Gallagher Group Limited 2004. All rights reserved. Patents Pending. 3C4480 R10 May 2005 DISCLAIMER Whilst every effort has been made to ensure accuracy, neither Gallagher Group Limited nor any employee of the company, shall be liable on any ground whatsoever to any party in respect of decisions or actions they may make as a result of using this information. In accordance with the Gallagher policy of continuing development, design and specifications are subject to change without notice. Developed and manufactured by Gallagher Group Limited, an ISO 9001:2000 Certified Supplier.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2005:05:17 22:16:30Z Modify Date : 2005:05:18 10:24:46+12:00 Page Count : 16 Creation Date : 2005:05:17 22:16:30Z Mod Date : 2005:05:18 10:24:46+12:00 Producer : Acrobat Distiller 5.0.5 (Windows) Author : traceyr Metadata Date : 2005:05:18 10:24:46+12:00 Creator : traceyr Title : Microsoft Word - 3C4480 Prox Plus Mifare reader Installation Note.docEXIF Metadata provided by EXIF.tools