Page  1   3E4290 Gallagher T12 Reader | Edion 1 | August 2016 Copyright © Gallagher Group LimitedGallagher T12 ReaderInstallaon NoteT12 Mifare Reader Black: C300420T12 Mifare Reader White: C300421T12 Mul Tech Reader Black: C300440T12 Mul Tech Reader White: C300441
Page  2   3E4290 Gallagher T12 Reader | Edion 1 | August 2016 Copyright © Gallagher Group LimitedDisclaimerThis document gives certain informaon about products and/or services provided by Gallagher Group Limited or its related companies (referred to as "Gallagher Group").The informaon is indicave only and is subject to change without noce meaning it may be out of date at any given me.  Although every commercially reasonable eort has been taken to ensure the quality and accuracy of the informaon, Gallagher Group makes no representaon as to its accuracy or completeness and it should not be relied on as such.  To the extent permied by law, all express or implied, or other representaons or warranes in relaon to the informaon are expressly excluded. Neither Gallagher Group nor any of its directors, employees or other representaves shall be responsible for any loss that you may incur, either directly or indirectly, arising from any use or decisions based on the informaon provided.Except where stated otherwise, the informaon is subject to copyright owned by Gallagher Group and you may not sell it without permission.  Gallagher Group is the owner of all trademarks reproduced in this informaon.  All trademarks which are not the property of Gallagher Group, are acknowledged.Copyright © Gallagher Group Ltd 2016.  All rights reserved.
Page  3   3E4290 Gallagher T12 Reader | Edion 1 | August 2016 Copyright © Gallagher Group LimitedContents1  Introducon ..................................................................................................................................... 42  Before you begin .............................................................................................................................. 43  Distance between readers ............................................................................................................... 74  Installaon ....................................................................................................................................... 75  LED indicaons ............................................................................................................................... 106  Accessories .................................................................................................................................... 107  Technical specicaons .................................................................................................................. 118  Approvals and standards ................................................................................................................ 129  Mounng dimensions .................................................................................................................... 13
Page  4   3E4290 Gallagher T12 Reader | Edion 1 | August 2016 Copyright © Gallagher Group Limited1 IntroduconThe Gallagher T12 Reader is a mobile credenal and smart card proximity reader.  It can be installed as either an entry reader or exit reader.  It can be mounted on a BS 4662 Brish Standard square ush box.The reader sends informaon to the Gallagher Controller and acts upon informaon sent from the Gallagher Controller.  The reader itself does not make any access decisions.The reader is available in four variants.  The card technologies for each variant are shown below.Reader Product codes Supported card technologiesT12 Mifare Reader Black T12 Mifare Reader WhiteC300420 C300421Mifare DESFire EV1, Mifare Plus and Mifare ClassicT12 Mul Tech Reader Black T12 Mul Tech Reader WhiteC300440 C300441Mifare DESFire EV1, Mifare Plus, Mifare Classic and 125 KHz cardsThe reader can be connected as an HBUS Reader or Cardax IV Reader.  An HBUS Reader uses the HBUS communicaons protocol to communicate with the Gallagher Controller.  A Cardax IV Reader uses the Cardax IV Reader communicaons protocol to communicate with the Gallagher Controller.  IMPORTANT: HBUScompability HBUS communicaons are supported with sites running Gallagher Command Centre vEL7.00 soware (or later).IMPORTANT: MulTechreaders Using dual technology 125/Mifare cards with Gallagher Mul Tech readers may cause both card technologies to be read, resulng in double card badges and unusual reader feedback.  Gallagher strongly recommends against using dual technology 125/Mifare cards with Mul Tech readers for sites running pre-Command Centre v7.00 soware.  From Command Centre v7.00, a site may specify which technology a Mul Tech reader should read o a dual technology card.IMPORTANT: Mobilecredenalreaders Gallagher Mul Tech readers support Gallagher mobile credenals using Bluetooth® wireless technology.  Mobile credentials are supported with sites running Gallagher Command Centre vEL7.60 soware (or later).  To use mobile credenals, the Mul Tech reader must be connected as an HBUS Reader.2 Beforeyoubegin2.1  Shipment contentsCheck the shipment contains the following items:•  1 x Gallagher T12 Reader facia assembly•  1 x Gallagher T12 Reader bezel•  1 x M3 Torx Post Security screw•  2 x M3.5 Phillips drive xing screws•  4 x 25 mm No.6 self tapping, pan head, Phillips drive xing screws•  4 x 40 mm No.6 self tapping, pan head, Phillips drive xing screws
Page  5   3E4290 Gallagher T12 Reader | Edion 1 | August 2016 Copyright © Gallagher Group Limited2.2 PowersupplyThe Gallagher T12 Reader is designed to operate over a supply voltage range of 9 - 16 Vdc measured at the reader terminals.  The operang current draw is dependant on the supply voltage at the reader.  For the Mifare reader, at 13.6 Vdc the current draw is 84 mA (idle).  During card read, beeper and LED acvity, the current will momentarily reach 113 mA (maximum).  For the Mul Tech reader, at 13.6 Vdc the current draw is 100 mA (idle) and will momentarily reach 124 mA (maximum).  The power source should be linear or a good quality switched-mode power supply.  The performance of the reader may be aected by a low quality, noisy power supply.2.3 CablingThe Gallagher T12 Reader requires a minimum cable size of 4 core 24 AWG (0.2 mm2) stranded security cable.  This cable allows the transmission of data (2 wires) and power (2 wires).  When using a single cable to carry both power supply and data, both the power supply voltage drop and data requirements must be considered.  Although the reader is specied to operate at 9 Vdc, for good engineering design it is recommended that the voltage at the reader should be approximately 12 Vdc. HBUScablingtopologyThe HBUS communicaons protocol is based on the RS485 standard and allows the reader to communicate over a distance of up to 500 m (1640 ).  The cabling between HBUS devices should be done in a "daisy chain" topology, (i.e. A "T" or "Star" topology should not be used between devices).  Should "Star" or "Home-Run" wiring be required, the HBUS 4H/8H Modules and the HBUS Door Module allow mulple HBUS devices to be individually wired to the one physical locaon.The end devices on the HBUS cable should be terminated using 120 ohms resistance.  To terminate the Gallagher Controller 6000, connect the supplied on-board terminaon jumpers to the Controller.  To terminate a reader, connect the orange (terminaon) wire to the green (HBUS A) wire.  Terminaon is already included at the HBUS Module, (i.e. each HBUS port is permanently terminated at the module).Connect the on-board terminaon jumperController 6000RS485 1HBUS Device"T" or "Star" circuits are not permied between HBUS devicesHBUS DeviceTerminateHBUS DeviceHBUS DeviceHBUS Device
Page 6   3E4290 Gallagher T12 Reader | Edion 1 | August 2016 Copyright © Gallagher Group LimitedHBUS DeviceHBUS DeviceHBUS DeviceTerminateRemove the on-board terminaon jumperRS485 1"T" or "Star" circuits are not permied between HBUS devicesHBUS DeviceTerminateHBUS Device Controller 6000HBUS Device"T" or "Star" circuits are not permied between HBUS devicesController 6000H1 H4H8H5HBUS DeviceTerminateHBUS DeviceTerminateHBUS ModuleHBUS DeviceHBUS DeviceTerminateHBUS DeviceTerminateHBUS Device CabledistanceCabletype Cableformat* HBUS  single reader connected using dataonlyinasinglecableCardax IV single reader connected using dataonlyinasinglecable***HBUS/Cardax IV single reader connected  using  power and data inasinglecableCAT 5e or beer**4 twisted pair Each 2 x 0.2 mm2 (24 AWG)500 m (1640 ) 200 m (650 ) 100 m (330 )BELDEN 9842** (shielded)2 twisted pair Each 2 x 0.2 mm2 (24 AWG)500 m (1640 ) 200 m (650 ) 100 m (330 )SEC472 4 x 0.2 mm2 Not twisted pairs (24 AWG)400 m (1310 ) 200 m (650 ) 100 m (330 )SEC4142 4 x 0.4 mm2 Not twisted pairs (21 AWG)400 m (1310 ) 200 m (650 ) 150 m (500 )* The matching of wire sizes to equivalent wire gauges are only approximate.
Page  7   3E4290 Gallagher T12 Reader | Edion 1 | August 2016 Copyright © Gallagher Group Limited** Recommended cable types for opmal HBUS RS485 performance. *** Not applicable for Gallagher mobile credenal reader installaons.Notes:•  Shielded cable may reduce the obtainable cable length.  Shielded cable should be grounded at the Controller end only.  •  If other cable types are used, operang distances and performance may be reduced depending on the cable quality.•  HBUS allows up to 20 readers to be connected to a single cable.  Each reader requires at least 9 Vdc to funcon correctly.  The cable length and the number of readers connected will have an impact on the voltage at each reader.3 DistancebetweenreadersThe distance separang any two proximity readers must not be less than 200 mm (8 in) in all direcons.  When mounng a proximity reader on an internal wall, check that any reader xed to the other side of the wall is not less than 200 mm (8 in) away.200 mm    200 mm4 InstallaonATTENTION:  This equipment contains components that can be damaged by electrostac discharge.  Ensure both you and the equipment are earthed before beginning any servicing.The Gallagher T12 Reader is designed to be mounted on a standard Brish electrical ush box, or any solid at surface.  However installaon on metal surfaces, parcularly those with a large surface area will reduce read range.  The extent to which the range is reduced will depend upon the type of metal surface.Note:  Consideraon should be given to the installaon environment when using Gallagher mobile credenals, as the Bluetooth® wireless technology read range may be reduced.The recommended mounng height for the reader is 1.1 m (3.6 ) from the oor level to the centre of the reader device.  However this may vary in some countries and you should check local regulaons for variaons to this height.1.  Ensure the building cable has been run out through the ush box.If you are not mounng to a ush box, use the reader bezel as a guide to drill all ve holes.  Drill the 13 mm (1/2 inch) diameter centre hole (this is the centre hole for which the building cable will exit the mounng surface) and the four xing holes.
Page  8   3E4290 Gallagher T12 Reader | Edion 1 | August 2016 Copyright © Gallagher Group Limited2.  Run the building cabling out through the centre hole and through the reader bezel.3.  Secure the bezel to the ush box using the two M3.5 screws provided.  It is important the bezel of the reader is ush with and ght against the mounng surface.If you are not mounng to a ush box, secure the bezel to the mounng surface using the four xing screws provided.Note:  It is strongly recommended that you use the screws provided.  If an alternave screw is used, the head must be no larger nor deeper than that of the screw provided.Note:  Ensure the centre hole allows the cable to run freely out through the mounng surface, so that the reader facia can clip into the bezel.BezelBuilding cableM3.5 screwM3.5 screw4.  Connect the reader tail extending from the facia assembly to the building cable.  Connect the wires for the appropriate reader you wish to interface, either an HBUS Reader or a Cardax IV Reader, as shown in the following diagrams.Note:  Mobile credenal readers must be connected as HBUS Readers.  An HBUS Reader connects to a Gallagher Controller 6000, Gallagher 4H/8H Module (aached to a Controller 6000) or a Gallagher HBUS Door Module (connected to a Controller 6000).A Cardax IV Reader connects to a Gallagher Controller 6000, Gallagher 4R/8R Module (aached to a Controller 6000), Gallagher GBUS Universal Reader Interface (Gallagher GBUS URI), Gallagher Controller 3000-8R or 3000-4R, Gallagher Local Bus Universal Reader Interface (Gallagher URI) or a Gallagher Local Bus Reader I/O Interface.HBUS Reader connecon:      HBUS Reader terminated:Posive RedNegave BlackHBUS Terminaon OrangeHBUS A GreenHBUS B BrownCDXIV TX WhiteCDXIV RX BlueHBUS Reader Posive RedNegave BlackHBUS Terminaon OrangeHBUS A GreenHBUS B BrownCDXIV TX WhiteCDXIV RX BlueHBUS ReaderNote:  To terminate an HBUS Reader, connect the Orange (HBUS Terminaon) wire to the Green (HBUS A) wire.
Page  9   3E4290 Gallagher T12 Reader | Edion 1 | August 2016 Copyright © Gallagher Group LimitedCardax IV Reader connecon:Posive RedNegave BlackHBUS Terminaon OrangeHBUS A GreenHBUS B BrownCDXIV TX WhiteCDXIV RX BlueCardax IV Reader5.  Fit the facia assembly into the bezel by clipping the small lip, into the top of the bezel and holding the top, press the boom of the facia assembly down into the bezel.6.  Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver) through the hole at the boom of the bezel to secure the facia assembly.  Note:  The Torx Post Security screw needs only to be lightly ghtened.BezelFit screw to secure facia to bezelConneconReader tailBuilding cableFacia7.  Removal of the facia assembly is a simple reversal of these steps.8.  Congure the reader in Command Centre.  If the reader is connected as an HBUS Reader, refer to the topic "Conguring HBUS Devices" in the Command Centre Conguraon Client Online Help.  If the reader is connected as a Cardax IV Reader, refer to the topic "Creang Readers" in the Command Centre Conguraon Client Online Help.
Page 10   3E4290 Gallagher T12 Reader | Edion 1 | August 2016 Copyright © Gallagher Group Limited5 LEDindicaonsLED (squiggle) HBUSindicaon3 Flash (Amber) No communicaons with the Controller.2 Flash (Amber) Communicaons with the Controller, but reader is not congured.1 Flash (Amber)  Congured to a Controller, but reader is not assigned to a door or elevator car.On (Green or Red) Fully congured and funconing normally. Green  =  Access mode is Free Red      =  Access mode is SecureFlashes Green Access has been granted.Flashes Red Access has been denied.Flashes (Blue) Reading a Gallagher mobile credenal.LED (squiggle) CardaxIVindicaon3 Flash (Amber) No communicaons with the Controller.On (Green or Red) Fully congured and funconing normally. Green  =  Access mode is Free Red      =  Access mode is SecureFlashes Green Access has been granted.Flashes Red Access has been denied.6 AccessoriesAccessory Product CodeT12 Dress Plate, Black, Pk 10 C300322T12 Bezel, Black, Pk 10 C300288T12 Bezel, White, Pk 10 C300289T12 Bezel, Silver, Pk 10 C300290T12 Bezel, Gold, Pk 10 C300291T12 Spacer, Black, Pk 10 C300304T12 Spacer, White, Pk 10 C300305T11/T12 Protecve Cover Spacer C300311T11/T12 Protecve Cover C300271
Page  11   3E4290 Gallagher T12 Reader | Edion 1 | August 2016 Copyright © Gallagher Group Limited7 TechnicalspecicaonsRoune maintenance: Not applicable for this readerCleaning: This reader should only be cleaned with a clean, lint free, damp clothVoltage: 9 Vdc - 16 VdcCurrent: Mifare Reader Mul Tech ReaderIdle 1 Maximum 2 Idle 1 Maximum 2at 9 Vdc 124 mA 175 mA 115 mA 164 mAat 13.6 Vdc 84 mA 113 mA 100 mA 124 mATemperature range: -35 °C to +70 °C   Note:  Direct sunlight may increase the internal reader temperature above the ambient temperature levelHumidity:   0 - 95% non-condensing 3Environmental protecon: IP68Impact rang: IK07Unit dimensions: Height 86 mm (3.4") Width 86 mm (3.4") Depth 12 mm (0.5")Maximum number of readers on one HBUS cable:201  The reader is idle.2  Peak current during card read.3  Gallagher T Series readers are UL humidity tested and cered to 85% and have been independently veried to 95%.Note:  The current values stated above have been reported using the default conguraon for a reader in Command Centre.  Changing the conguraon may vary the current value.
Page  12   3E4290 Gallagher T12 Reader | Edion 1 | August 2016 Copyright © Gallagher Group Limited8  Approvals and standardsThis symbol on the product or its packaging indicates that this product must not be disposed of with other waste.  Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collecon point for the recycling of waste electrical and electronic equipment.  The separate collecon and recycling of your waste equipment at the me of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment.  For more informaon about where you can drop o your waste equipment for recycling, please contact your local city recycling oce or the dealer from whom you purchased the product.FCC This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operaon.Note:  Changes or modicaons not expressly approved by Gallagher Limited could void the user's authority to operate this equipment.Note:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protecon against harmful interference in a residenal installaon.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instrucons, may cause harmful interference to radio communicaons.  However, there is no guarantee that interference will not occur in a parcular installaon.  If this equipment does cause harmful interference to radio or television recepon, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:•  Reorient or relocate the receiving antenna. •  Increase the separaon between the equipment and receiver.•  Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.•  Consult the dealer or an experienced radio/TV technician for help.IndustryCanadaThis device complies with Industry Canada licence-exempt RSS standard(s).  Operaon is subject to the following two condions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operaon of the device.Industrie CanadaLe présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.  L'exploitaon est autorisée aux deux condions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'ulisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est suscepble d'en compromere le fonconnement.ETSI EN 300 330-2 V1.5.1:2011 EN50130-4:2011                    Please refer to the document “3E2793 Gallagher Command Centre UL Conguraon Requirements” for a guide to conguring the Gallagher system to the appropriate UL Standard.US - Equipment: com, burg and acc reader CA - Equipment: com, burg reader
Page  13   3E4290 Gallagher T12 Reader | Edion 1 | August 2016 Copyright © Gallagher Group Limited9 MounngdimensionsIMPORTANT This picture is not to scale, therefore use the measurements provided.35 mm (1.38")26 mm (1") 29 mm (1.14")86 mm (3.39")13 mm (1/2") diameter hole for cable86 mm (3.39")25 mm (1")30 mm (1.18")22.3 mm (0.88")40 mm (1.57")10 mm (0.39")