,QVWDOODWLRQ
,QVWUXFWLRQV
*DV'U\HU
4XHVWLRQVRQ,QVWDOODWLRQ"&DOO*(&$5(686RU&DQDGD
RUYLVLWRXUZHEVLWHDWZZZ*($SSOLDQFHVFRP86
%()25(<28%(*,1
:$51,1*5,6.2)),5(
5HDGWKHVHLQVWUXFWLRQV
FRPSOHWHO\DQGFDUHIXOO\
,03257$176DYH
WKHVHLQVWUXFWLRQVIRUORFDO
LQVSHFWRU·VXVH
,03257$172EVHUYH
DOOJRYHUQLQJFRGHVDQG
RUGLQDQFHV
1RWHWR,QVWDOOHU%HVXUHWR
OHDYHWKHVHLQVWUXFWLRQVZLWK
WKHFXVWRPHU
1RWHWR&XVWRPHU.HHSWKHVH
LQVWUXFWLRQVZLWK\RXU2ZQHU·V
0DQXDOIRUIXWXUHUHIHUHQFH
%HIRUHWKHROGGU\HULVUHPRYHG
IURPVHUYLFHRUGLVFDUGHG
UHPRYHWKHGU\HUGRRU
6HUYLFHLQIRUPDWLRQDQGWKH
ZLULQJGLDJUDPDUHORFDWHGLQ
WKHFRQWUROFRQVROH
'RQRWDOORZFKLOGUHQRQ
RULQWKHDSSOLDQFH&ORVH
VXSHUYLVLRQRIFKLOGUHQLV
QHFHVVDU\ZKHQWKHDSSOLDQFH
LVXVHGQHDUFKLOGUHQ
,QVWDOOWKHGU\HUZKHUHWKH
WHPSHUDWXUHLVDERYH)IRU
VDWLVIDFWRU\RSHUDWLRQRIWKH
GU\HUFRQWUROV\VWHP
3URGXFWIDLOXUHGXHWR
LPSURSHULQVWDOODWLRQLVQRW
FRYHUHGXQGHUWKH:DUUDQW\
7RUHGXFHWKHULVNRIVHYHUHLQMXU\RUGHDWKIROORZDOOLQVWDOODWLRQLQVWUXFWLRQV
&ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHU
,QVWDOOWKHFORWKHVGU\HUDFFRUGLQJWRWKHVHLQVWUXFWLRQVDQGLQDFFRUGDQFHZLWKORFDO
FRGHV
&DOLIRUQLD6DIH'ULQNLQJ:DWHUDQG7R[LF(QIRUFHPHQW$FW
7KLVDFWUHTXLUHVWKHJRYHUQRURI&DOLIRUQLDWRSXEOLVKDOLVWRIVXEVWDQFHVNQRZQWRWKH
VWDWHWRFDXVHFDQFHUELUWKGHIHFWVRURWKHUUHSURGXFWLYHKDUPDQGUHTXLUHVEXVLQHVVHV
WR ZDUQ FXVWRPHUV RI SRWHQWLDO H[SRVXUH WR VXFK VXEVWDQFHV *DV DSSOLDQFHV FDQ
FDXVHPLQRUH[SRVXUHWRIRXURIWKHVHVXEVWDQFHVQDPHO\EHQ]HQHFDUERQPRQR[LGH
IRUPDOGHK\GHDQGVRRWFDXVHGSULPDULO\E\WKHLQFRPSOHWHFRPEXVWLRQRIQDWXUDOJDV
RU/3IXHOV3URSHUO\DGMXVWHGGU\HUVZLOOPLQLPL]HLQFRPSOHWHFRPEXVWLRQ([SRVXUHWR
WKHVHVXEVWDQFHVFDQEHPLQLPL]HGIXUWKHUE\SURSHUO\YHQWLQJWKHGU\HUWRWKHRXWGRRUV
7KLVGU\HUPXVWEHH[KDXVWHGWRWKHRXWGRRUV
8VHRQO\ULJLGPHWDOµGLDPHWHUGXFWZRUNLQVLGHWKHGU\HUFDELQHWDQGXVHRQO\8/
DSSURYHGWUDQVLWLRQGXFWLQJEHWZHHQWKHGU\HUDQGWKHKRPHGXFW
'2127LQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJPDWHULDOV,IÀH[LEOHPHWDO
VHPLULJLGRUIRLOW\SHGXFWLVLQVWDOOHGLWPXVWEH8/OLVWHGDQGLQVWDOOHGLQDFFRUGDQFH
ZLWKWKHLQVWUXFWLRQVIRXQGLQ´&RQQHFWLQJ7KH'U\HU7R+RXVH9HQWµRQSDJHRIWKLV
PDQXDO)OH[LEOHYHQWLQJPDWHULDOVDUHNQRZQWRFROODSVHEHHDVLO\FUXVKHGDQGWUDS
OLQW7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZDQGLQFUHDVHWKHULVNRI¿UH
'RQRWLQVWDOORUVWRUHWKLVDSSOLDQFHLQDQ\ORFDWLRQZKHUHLWFRXOGEHH[SRVHGWR
ZDWHUDQGRUZHDWKHU
6DYHWKHVHLQVWUXFWLRQV,QVWDOOHUV%HVXUHWROHDYHWKHVHLQVWUXFWLRQVZLWKWKH
FXVWRPHU
,17+(&20021:($/7+2)0$66$&+86(776
7KLVSURGXFWPXVWEHLQVWDOOHGE\DOLFHQVHGSOXPEHURUJDV¿WWHU
:KHQXVLQJEDOOW\SHJDVVKXWRIIYDOYHVWKH\VKDOOEHWKH7KDQGOHW\SH
$IOH[LEOHJDVFRQQHFWRUZKHQXVHGPRVWQRWH[FHHGIHHW
MATERIALS YOU WILL NEED
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. METAL
ELBOW
TOOLS YOU WILL NEED
(x2)
SLIP JOINT PLIERS
10" ADJUSTABLE WRENCHES
8" PIPE WRENCH
LEVEL
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DUCT
CLAMPS (2)
OR
4" SPRING
CLAMPS (2)
EXHAUST
HOOD
PIPE
COMPOUND SOAP SOLUTION
FOR LEAK DETECTION
DUCT TAPE
SAFETY
GLASSES
FLAT BLADE SCREWDRIVER
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
6WHS 9HULI\\RXUJDVLQVWDOODWLRQVHHVHFWLRQ
6WHS 3UHSDUHWKHDUHDDQGH[KDXVWIRULQVWDOODWLRQRIQHZGU\HU
VHHVHFWLRQ
6WHS &KHFNDQGHQVXUHWKHH[LVWLQJH[WHUQDOH[KDXVWLVFOHDQVHH
VHFWLRQDQGPHHWVDWWDFKHGLQVWDOODWLRQVSHFL¿FDWLRQVVHH
VHFWLRQ
6WHS 5HPRYHWKHIRDPVKLSSLQJSDGVVHHVHFWLRQ
6WHS 0RYHWKHGU\HUWRWKHGHVLUHGORFDWLRQ
6WHS /HYHO\RXUGU\HUVHHVHFWLRQ
6WHS &RQQHFWWKHJDVVXSSO\VHHVHFWLRQDQGFKHFNIRUOHDNV
VHHVHFWLRQ
6WHS &RQQHFWWKHH[WHUQDOH[KDXVWVHHVHFWLRQ
FLEXIBLE GAS LINE CONNECTOR
GLOVES
6WHS &RQQHFWWKHSRZHUVXSSO\VHHVHFWLRQ
6WHS&KHFNWKHRSHUDWLRQRIWKHSRZHUVXSSO\JDVFRQQHFWLRQV
DQGYHQWLQJ
6WHS3ODFHWKH2ZQHU·V0DQXDODQGWKH,QVWDOODWLRQ,QVWUXFWLRQVLQ
DORFDWLRQZKHUHWKH\ZLOOEHQRWLFHGE\WKHRZQHU
)RUDOFRYHRUFORVHWLQVWDOODWLRQVHHVHFWLRQ
)RUEDWKURRPRUEHGURRPLQVWDOODWLRQVHHVHFWLRQ
)RUPRELOHRUPDQXIDFWXUHGKRPHVHHVHFWLRQ
)RUJDUDJHLQVWDOODWLRQLIDOORZHGE\ORFDOFRGHVVHHVHFWLRQ
)RUVLGHRUERWWRPH[KDXVWVHHVHFWLRQ
'3*(
,QVWDOODWLRQ,QVWUXFWLRQV
0LQLPXP&OHDUDQFH2WKHU7KDQ$OFRYHRU&ORVHW,QVWDOODWLRQ
0LQLPXPFOHDUDQFHWRFRPEXVWLEOHVXUIDFHVDQGIRUDLURSHQLQJDUHLQFOHDUDQFHERWKVLGHVLQIURQWLQUHDU
&RQVLGHUDWLRQPXVWEHJLYHQWRSURYLGHDGHTXDWHFOHDUDQFHIRULQVWDOODWLRQDQGVHUYLFH
35(3$5,1*)25,167$//$7,21
*$65(48,5(0(176
2)1(:'5<(5
:$51,1*
7,3,QVWDOO\RXUGU\HUEHIRUHLQVWDOOLQJ\RXUZDVKHU
7KLVZLOODOORZEHWWHUDFFHVVZKHQLQVWDOOLQJGU\HU
H[KDXVW
,QVWDOODWLRQPXVWFRQIRUPWRORFDOFRGHVDQG
RUGLQDQFHVRULQWKHLUDEVHQFHWKH1$7,21$/)8(/*$6
&2'($16,=
7KLVJDVGU\HULVHTXLSSHGZLWKD9DOYH %XUQHU
$VVHPEO\IRUXVHRQO\ZLWKQDWXUDOJDV8VLQJFRQYHUVLRQ
NLW:(;\RXUORFDOVHUYLFHRUJDQL]DWLRQFDQ
FRQYHUWWKLVGU\HUIRUXVHZLWKSURSDQH/3JDV$//
&219(56,2160867%(0$'(%<3523(5/<75$,1('
$1'48$/,),('3(56211(/$1',1$&&25'$1&(:,7+
/2&$/&2'(6$1'25',1$1&(5(48,5(0(176
7KHGU\HUPXVWEHGLVFRQQHFWHGIURPWKHJDVVXSSO\
SLSLQJV\VWHPGXULQJDQ\SUHVVXUHWHVWLQJRIWKDWV\V
WHPDWDWHVWSUHVVXUHLQH[FHVVRI36,.3D
7KHGU\HUPXVWEHLVRODWHGIURPWKHJDVVXSSO\SLSLQJ
V\VWHPE\FORVLQJWKHHTXLSPHQWVKXWRȺYDOYHGXULQJ
DQ\SUHVVXUHWHVWLQJRIWKHJDVVXSSO\SLSLQJRIWHVW
SUHVVXUHHTXDOWRRUOHVVWKDQ36,.3D
',6&211(&7,1**$6
TURN GAS
SHUT-OFF
VALVE TO THE
OFF POSITION.
DISCONNECT AND DISCARD OLD
FLEXIBLE GAS CONNECTOR AND
OLD DUCTING MATERIAL.
REPLACE WITH NEW CSA(AGA)
APPROVED FLEXIBLE GAS LINE
CONNECTOR AND UL APPROVED
TRANSITION DUCT.
:$51,1*1(9(55(86(
2/')/(;,%/(&211(&7256
7KHXVHRIROGÀH[LEOHFRQQHFWRUVFDQFDXVHOHDNV
DQGSHUVRQDOLQMXU\$OZD\VXVHQHZÀH[LEOH
FRQQHFWRUVZKHQLQVWDOOLQJJDVDSSOLDQFHV
'5<(5*$66833/<&211(&7,21
5(029,1*/,17)520:$//(;+$867
23(1,1*
2"
5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLO
WUDQVLWLRQGXFWDQGUHSODFHZLWK8/OLVWHGWUDQVLWLRQGXFW
WALL
INTERNAL DUCT
OPENING
2-5/8"
3/8" NPT MALE THREAD GAS SUPPLY
NOTE: Add to vertical dimension
the distance between cabinet
bottom to floor.
CHECK THAT EXHAUSE
HOOD DAMPER OPENS
AND CLOSES FREELY.
$LQ1DWLRQDO3LSH7DSHUWKUHDGSOXJJHGWDSSLQJ
DFFHVVLEOHIRUWHVWJDXJHFRQQHFWLRQPXVWEHLQVWDOOHG
LPPHGLDWHO\XSVWUHDPRIWKHJDVVXSSO\FRQQHFWLRQWR
WKHGU\HU&RQWDFW\RXUORFDOJDVXWLOLW\VKRXOG\RXKDYH
TXHVWLRQVRQWKHLQVWDOODWLRQRIWKHSOXJJHGWDSSLQJ
6XSSO\OLQHLVWREHLQULJLGSLSHDQGHTXLSSHGZLWK
DQDFFHVVLEOHVKXWRȺZLWKLQIWRIDQGLQWKHVDPH
URRPZLWKWKHGU\HU
8VHSLSHWKUHDGVHDOHUFRPSRXQGDSSURSULDWHIRUQDWX
UDORU/3JDVRUXVH7HÀRQWDSH
&RQQHFWÀH[LEOHPHWDOFRQQHFWRUWRGU\HUDQGJDVVXSSO\
2SHQVKXWRȺYDOYH
Source Exif Data:
File Type : PDF
File Type Extension : pdf
MIME Type : application/pdf
PDF Version : 1.6
Linearized : Yes
Author : 220038803
Create Date : 2011:08:24 11:08:47-04:00
Modify Date : 2011:08:24 11:08:47-04:00
Trapped : False
XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date : 2011:08:24 11:08:47-04:00
Creator Tool : Adobe InDesign CS4 (6.0.6)
Format : application/pdf
Title : 31-16630-2_EN_HiRes.pdf
Creator : 220038803
Document ID : uuid:b314833a-116e-4e62-9b26-838048ca606d
Instance ID : uuid:0dada916-3c02-4451-87e7-cc6f48804591
Producer : Acrobat Distiller 9.4.5 (Windows)
Page Count : 16
EXIF Metadata provided by EXIF.tools