DSXH43EFWW

F

Door Open

GE® Extra-Large 5.7 Cu. Ft. Capacity 90°
Frontload
Electric Dryer
Optional
Vent Knockout

Dimensions and Installation Information (in inches)

C
SIDE VIEW

Exhaust Options: Electric—4-way via rear, right, left
and bottom.
Circuit Requirements: Electric—An individual,
properly-grounded branch circuit, protected by a 30amp circuit breaker or a time-delay fuse, is required.

B

Electric Dryer Rating:
120/240V, 3-wire, 5600W, 24A
120/208V, 3-wire, 4400W, 22A

E

Electric
Connection

Note: Dryer wall outlet must be located within 36”
of service cord entry and accessible when dryer is
mounted in position.
Installation Information: For complete information,
see installation instructions packed with your dryer.

G

H
I

Under
Counter
D

A

J

F
Door Open
90°
Optional
Vent Knockout
C

3/16"
Gas Pipe Connection

SIDE VIEW

G

REAR VIEW
B

27" Min.
Electric
Connection
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
geappliances.com or call GE Answer Center®
service, 800.626.2000.

27"
Min.

34-5/8"
Min.

27" Min.

Note:
Under
H
ClosetCounter
Installation
Requ
A
I
MinimumD Clearances:
Listed by
Underwriters
Laboratories to Ceil
Top of Dryer
J
Back of Dryer to Wa
3/16"
360426
Specification Revised 12/09
Gas Pipe Connection
Front of Dryer/Wash
REAR VIEW to Closet Door

DSXH43EFWW
GE® Extra-Large 5.7 Cu. Ft. Capacity Frontload Electric Dryer
Dimensions and Installation Information (in inches)

Free-Standing Installation

Raised/ Built-in Installation

Special Installation Requirements
Undercounter Installation
Accessory mounting kits are required for undercounter installation. To order,
call 1-800-848-7722.
Stacked Installation: Brackets for stacking dryer over washer are included with
the dryer.
Alcove or Closet Installation:If your dryer is approved for installation in an
alcove or closet, it will be stated on a label on the dryer back. The dryer MUST
be exhausted to the outdoors. Minimum clearances between dryer cabinet and
­adjacent walls or other surfaces are: 0" either side, 3" front and rear Minimum
vertical space from floor to overhead ­cabinets, ceilings, etc. is 52". Closet doors
must be louvered or otherwise ventilated and must contain a minimum of 60
sq. in. of open area equally distributed. If this closet contains both a washer
and a dryer, doors must contain a minimum of 120 sq. in. of open area equally
distributed. The closet should be vented to the outdoors to prevent gas pocketing
in case of a gas leak in the supply line. No other fuel-burning appliance shall be
installed in the same closet with the dryer.
Bathroom or Bedroom Installation: The dryer must be exhausted to the
outdoors. The installation must conform with the local codes, or in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.

36"

25-3/4"

53-1/2"

Stacked Installation

511LF1

14''

29''

56''-60''
Max.

Undercounter Installation
70-5/8"

Countertop

Washer
Top Sheet

Minimum Clearances other than Alcove or Closet Installations:
Minimum clearances to combustible surfaces: 0" both sides, 3" rear

For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
geappliances.com or call GE Answer Center®
service, 800.626.2000.

3/4" Wide
3/4" High xon All Sides
Lip

Dryer
Top Sheet

511LF3
25-3/4"
26-3/4"

Listed by
Underwriters
Laboratories

511LF4

Specification Revised 12/09

511LF2

360426

DSXH43EFWW
GE® Extra-Large 5.7 Cu. Ft. Capacity Frontload Electric Dryer
Dryer Exhausting Information – Metal Duct Only
For complete information, see installation instructions packed with your dryer.
Ducting Materials: For best performance, this dryer should be vented with 4” diameter all rigid
metal exhaust duct. If “all rigid metal” duct cannot be used, then “flexible all metal” venting can
be used, but it will reduce the maximum recommended duct length.
Exhaust Length Calculation:
1.	 Determine the number of 90° turns needed for your installation. If you exhaust to the
	 side or bottom of dryer, add one turn.
2.	 The maximum length of 4’ rigid (aluminum or galvanized) duct which can be tolerated is
	 shown in the table. The maximum length for flexible ducts are less than for rigid duct.
	 A turn of 45° or less may be ignored. Two 45° turns within the duct length should be
	 treated as a 90° elbow.
	 A turn over 45° should be treated as a 90° elbow.
Exhausting the dryer to the outside is strongly recommended to prevent large amounts of
moisture and lint from being blown into the room. Gas dryers or any dryer located in a closet
must be exhausted to the outside.

Best performance
A
4

B
2-1/2

Frontload dryers:
DSXH43EF/GF
DSXH47EG/GG

Maximum length of
4” dia. rigid metal duct
Exhaust hood type

Number
of
90°
turns

A
4" opening

0
1
2
3
4

60 ft.
52 ft.
44 ft.
32 ft.
28 ft.

B
2-1/2"
opening
48 ft.
40 ft.
32 ft.
24 ft.
16 ft.

Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed
house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard
or moisture could cause damage. Never terminate the exhaust into a common duct or plenum
with a kitchen exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird
nesting, etc. The wall cap must also be located at least 12" above the ground or any other
obstruction with the opening pointed Down.
Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent
to a 4" opening dampered wall cap.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
geappliances.com or call GE Answer Center®
service, 800.626.2000.
Listed by
Underwriters
Laboratories

Specification Revised 12/09

360426

DSXH43EFWW
GE® Extra-Large 5.7 Cu. Ft. Capacity Frontload Electric Dryer
Features and Benefits
•	 Extra-Large (5.7 cu. ft.) Capacity
•	 Tumble Drying
•	 4 Temperature Options: Regular/Cottons, Medium/Permanent Press,
	 Low/Delicates and Air Fluff/No Heat (Cool Down)
•	 1 Time Dry Cycle
•	 2 Auto Dry Cycles: Cottons and Easy Care
•	 Adjustable End-of-Cycle Signal
•	 Quick Clean Lint Screen
•	 Drying Rack
•	 Spill-Saver Top
•	 Interior Dryer Light
•	 Dura Finish Top and Drum
•	 Leveling Legs
•	 Heavy Duty Suspension System
•	 4 Exhaust Option
•	 Reverse-A-Door
•	 100% Front Serviceable
•	 Model DSXH43EFWW - White on white (Electric)
•	 Model DSXH43GFWW - White on white (Gas)

Specification Revised 12/09

360426



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c006 1.236519, Wed Jun 14 2006 08:31:24
Create Date                     : 2009:12:11 14:32:23-05:00
Metadata Date                   : 2009:12:11 14:32:39-05:00
Modify Date                     : 2009:12:11 14:32:39-05:00
Creator Tool                    : Adobe InDesign CS3 (5.0.2)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 8852 bytes, use -b option to extract)
Document ID                     : adobe:docid:indd:a3200553-2854-11da-81ad-fd75f72bfb52
Instance ID                     : uuid:61de0292-f6c5-4acc-bfea-51bc52ba8638
Rendition Class                 : proof:pdf
Derived From Instance ID        : c45b9190-26d6-11da-804c-8eae9549b427
Derived From Document ID        : adobe:docid:indd:9242f59e-26bf-11da-804c-8eae9549b427
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00, 72.00, 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:7904EB9D0A1C11DCBE5BC047A0678657, uuid:7904EB9D0A1C11DCBE5BC047A0678657, uuid:45A8BE78503111DEBB038B4C9E9CE6B7, uuid:45A8BE76503111DEBB038B4C9E9CE6B7, uuid:17091F1EDA7B11DEAFD0F47A6A56A45C
Manifest Reference Document ID  : uuid:FCD5F2F8D6E311DAA62EAFDD695641AF, uuid:FCD5F2F8D6E311DAA62EAFDD695641AF, uuid:45A8BE77503111DEBB038B4C9E9CE6B7, uuid:45A8BE75503111DEBB038B4C9E9CE6B7, uuid:17091F1DDA7B11DEAFD0F47A6A56A45C
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 4
Creator                         : Adobe InDesign CS3 (5.0.2)
EXIF Metadata provided by EXIF.tools

Navigation menu