Range Hoods

GE Appliances
Safety Information . . . . . . . . . 3

Owner’s Manual
and Installation
Instructions

Operating/Care and
Cleaning Instructions
Charcoal Filters . . . . . . . . . . . . .5
Grease Filters . . . . . . . . . . . . . . .4
Hood Lights . . . . . . . . . . . . . . . .5
Hood Surfaces . . . . . . . . . . . . . .5
Stainless Steel Surfaces . . . . . . .5
Vent Controls . . . . . . . . . . . . . . .4

JV535
JV536
JV565
JV566
JV635
JV636
JV665
JV666

Installation
Instructions . . . . . . . . . . . .6–14
Customer Service

Vented

Product Registration . . . . . . . . .2
Service Telephone
Numbers . . . . . . . . . Back Cover
Warranty . . . . . . . . . . . . . . . . . 15

www.geappliances.com

164D3333P240

49-80025

07-00 JR

626851A

Safety Instructions

GE & You, A Service Partnership.
IMPORTANT!
Fill out the Consumer Product Registration Card.

Two easy ways to register your appliance!
■ Through the internet at www.geappliances.com
■ Complete and mail the enclosed Product Registration Card

Operating Instructions

FOR YOUR RECORDS
Write the model and serial numbers here:
#
#
You can find them on a label on the back wall of the hood.

Staple sales slip or cancelled check here.
Proof of the original purchase date is needed to obtain service under the warranty.

Inside you will find many helpful hints on how to use and maintain your range hood properly.
Just a little preventive care on your part can save you a great deal of time and money over the life
of your range hood.

IF YOU NEED SERVICE
If you do need service, you can relax knowing help is only a phone call away. A list of toll-free
customer service numbers is included in the back section of this manual.

OR
Visit our Website at: www.geappliances.com

Customer Service

Installation Instructions

READ THIS MANUAL

2

SAFETY PRECAUTIONS
WARNING – TO REDUCE THE RISK OF

CAUTION – For general ventilating use only.
Do not use to exhaust hazardous or explosive
materials and vapors.

WARNING – TO REDUCE THE RISK OF

RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on
low or medium settings.
B. Always turn hood ON when cooking at high
heat or when cooking flaming foods.
C. Clean ventilating fans frequently. Grease
should not be allowed to accumulate on fan
or filter.
D. Use proper pan size. Always use cookware
appropriate for the size of the surface
element.

WARNING – TO REDUCE THE RISK OF

FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be
done by qualified person(s) in accordance
with all applicable codes and standards,
including fire-rated construction.
B. Sufficient air is needed for proper
combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating
equipment manufacturer’s guideline and
safety standards such as those published by
the National Fire Protection Association
(NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code
authorities.
C. When cutting or drilling into wall or ceiling,
do not damage electrical wiring and other
hidden utilities.
D. Ducted fans must always be vented to the
outdoors.
FIRE, USE ONLY METAL DUCTWORK.
■ Do not attempt to repair or replace any
part of your hood unless it is specifically
recommended in this guide. All other servicing
should be referred to a qualified technician.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
READ AND SAVE THESE INSTRUCTIONS
3

Customer Service

WARNING – TO REDUCE THE RISK OF

Installation Instructions

INJURY TO PERSONS IN THE EVENT OF A RANGE
TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
A. SMOTHER FLAMES with a close-fitting
lid, cookie sheet, or metal tray, then turn off
the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out
immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
B. NEVER PICK UP A FLAMING PAN—
You may be burned.
C. DO NOT USE WATER, including wet
dishcloths or towels—a violent steam
explosion will result.
D. Use an extinguisher ONLY if:
1. You know you have a Class ABC
extinguisher, and you already know how
to operate it.
2. The fire is small and contained in the
area where it started.
3. The fire department is being called.
4. You can fight the fire with your back to
an exit.
* Based on “Kitchen Firesafety Tips” published
by NFPA.

WARNING – TO REDUCE THE RISK OF A

Operating Instructions

FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended
by the manufacturer. If you have questions,
contact the manufacturer.
B. Before servicing or cleaning unit, switch
power off at service panel and lock the service
disconnecting means to prevent power from
being switched on accidentally. When the
service disconnecting means cannot be
locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
C. Do not use this unit with any solid-state speed
control device.
D. This unit must be grounded.

Safety Instructions

IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.

Safety Instructions

Using the hood controls.
Throughout this manual, features and appearance may vary from your model.

Customer Service

Installation Instructions

Operating Instructions

Your model will have one of the above type of controls.

FAN Control

LIGHT Control

Turn or press (according to your model) the FAN
speed control to LO, MED, HI or BOOST, as needed.

Turn or press (according to your model) the LIGHT
control to BRIGHT for bright light while cooking.
Turn or press to NITE for use as a night light.

Continuous use of the fan system while cooking
helps keep the kitchen comfortable and less
humid. It also reduces cooking odors and soiling
moisture that create a frequent need for cleaning.

FAN ON Light
The FAN ON indicator light will glow when the fan
is turned on.

Care and cleaning of the vent hood.
Be sure electrical power is off and all surfaces are cool before cleaning or servicing any part of the
vent hood.
Reusable Metal Grease Filters
The hood has 2 metal reusable
grease filters.
The metal filters trap grease
released by foods on the cooktop.
They also help prevent flaming
foods on the cooktop from
damaging the inside of the hood.

If it ever becomes necessary to replace
the metal grease filters, they may be
ordered from your GE supplier.

For this reason, the filters must
ALWAYS be in place when the
hood is used. The grease filters
should be cleaned once a month,
or as needed.
To remove, slide the filters to the
rear using the tab. Pull them down
and out.
To replace, slide the filters in the
frame slot on the back of the
opening. Push up and back and
then to the front to lock into place.

4

To clean the grease filters, soak
them and then swish them around
in hot water and detergent.
Don’t use ammonia or ammonia
products because they will darken
the metal. Do not use abrasives or
oven cleaners. Light brushing can
be used to remove embedded dirt.
Rinse, shake and let them dry
before replacing. They may
also be cleaned in an automatic
dishwasher.

NOTE: Before cleaning, make sure the
charcoal filters, if present, are unclipped
and removed. See the Charcoal Filters
section.

The charcoal filters are clipped inside
of each reusable metal grease filter.

The charcoal filters
cannot be cleaned. They
must be replaced.
For 30″ hood models, order
Kit no. WB02X10707.
For 36″ hood models, order
Kit no. WB02X10708.
These kits can be ordered
from your GE supplier.

If the model is not vented
to the outside, the air will
be recirculated through
disposable charcoal
filters that help remove
smoke and odors.

The charcoal filters
should be replaced when
they are noticeably dirty
or discolored (usually
after 6 to 12 months,
depending on hood
usage).
NOTE: DO NOT rinse, or put
charcoal filters in an
automatic dishwasher.

To clean the hood surface, use a hot,
damp cloth with a mild detergent
suitable for painted surfaces. Use a
clean, hot, damp cloth to remove
soap. Dry with a dry, clean cloth.

Do not use steel-wool pads or other
abrasive cleaners. They will scratch
the surface. Wipe with a clean, hot,
damp cloth after using cleansers.

Stainless Steel Surfaces (on some models)
Do not use a steel-wool pad; it will
scratch the surface.

If food soil remains, try a general
kitchen cleaner, such as Fantastik®,
Simple Green®, or Formula 409®.

After cleaning, use a stainless steel
polish, such as Stainless Steel Magic®,
Revere Copper and Stainless Steel
Cleaner®, or Wenol All Purpose
Metal Polish®. Follow the product
instructions for cleaning the stainless
steel surface.

For hard-to-clean soil, use a
standard stainless steel cleaner, such
as Bon-Ami® or Cameo®.

Installation Instructions

To clean the stainless steel surface,
use a hot, damp cloth with a mild
detergent suitable for stainless steel
surfaces. Use a clean, hot, damp
cloth to remove soap. Dry with a dry,
clean cloth.

Apply cleaner with a damp sponge.
Use a clean, hot, damp cloth to
remove cleaner. Dry with a dry, clean
cloth. Always scrub lightly in the
direction of the grain.

Operating Instructions

Painted Surfaces (on some models)

Safety Instructions

Charcoal Filters (on some models)

Hood Lights

Purchase and install PAR20, 50 W
Maximum halogen bulbs.
When replacing a bulb, let it cool
first. Make sure that power to the light
has been turned off. Never allow a hot
bulb to come into contact with water.

To change the light bulbs:
Grasp the bulb on the edges and
unscrew it.
Replace with the same size bulb.

CAUTION:
■ Do not touch the hood light bulbs when they
are on. They may be hot enough to cause
injury.

■ The light bulbs operate at extremely high
temperatures. If they shatter, the hot glass
could cause personal injury.

5

Customer Service

This hood requires two bulbs (not
included), maximum 50 watts.

Range Hood

Installation
Instructions

Models JV535 JV635
JV536 JV636
JV565 JV665
JV566 JV666

Questions? Visit our Website at: www.geappliances.com or Call GE Answer Center at 800.626.2000

BEFORE YOU BEGIN

DUCTWORK REQUIREMENTS

Read these instructions completely and carefully.

NOTE: Read the ductwork sections only if you do not
have existing ductwork. If you have existing ductwork,
skip to the “Damage” section and proceed.

•

IMPORTANT – Save these
instructions for local inspector’s use.

•
•
•
•
•
•
•

The venting system must exhaust to the outside.

IMPORTANT – Observe all

This hood can be vented vertically through upper
cabinets or horizontally through an outside wall.
Ductwork is not included.

governing codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these instructions
for future reference.
Skill level – Installation of this appliance requires
basic mechanical and electrical skills.
Completion time – 1-3 hours
Proper installation is the responsibility of the
installer.
Product failure due to improper installation is not
covered under the Warranty.

Exhaust connection:
The hood exhaust has been designed to mate with
standard 31⁄4″ x 10″ rectangular ducting or 7″ diameter
round ducting.
If a 6″ round duct is required, a rectangular-to-round
transition adaptor must be used*. Do not use less than
a 6″ diameter duct.

Maximum duct length:
For satisfactory air movement, the total duct length
of a 31⁄4″ x 10″ rectangular, 6″ or 7″ diameter round
duct should not exceed 65 equivalent feet.
NOTE: It’s important that ducting be installed using
the most direct route and with as few elbows as possible.
This ensures clear venting of exhaust and helps prevent
blockages. Also, make sure dampers swing freely and
nothing is blocking the ducts.

FOR YOUR SAFETY:
WARNING – Before beginning the

installation, switch power off at service panel and lock
the service disconnecting means to prevent power
from being switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag,
to the service panel.

Elbows, transitions, wall and roofcaps, etc.,
present additional resistance to airflow and are
equivalent to a section of straight duct longer than their
actual physical size. When calculating the total duct
length, add the equivalent lengths of all transitions and
adaptors plus the length of all straight duct sections. The
charts on the following pages show you how to calculate
total equivalent ductwork length using the approximate
feet of equivalent length of some typical ducts.
* IMPORTANT: If a rectangular-toround transition adaptor is used, the
bottom corners of the damper will
have to be cut to fit, using the tin
snips, in order to allow free movement
of the damper.
Equivalent lengths of duct pieces
are based on actual tests and reflect
requirements for good venting
performance with any hood.

6

Installation Instructions
Follow the guidelines for proper duct sizing in the ducting charts.

DUCTING CHART–JV5 Series Models
Equivalent Length in Feet

Air Volume in CFM

250

0

25

•
•

200

50

75

•
•

100

•
•

150

31⁄4″ x 10″
Rectangular

125

150

7″ Round

•
•

•

100

125

•

100
31⁄4″ x 10″ Rectangular Transition to 6″ Round = 4.5 ft.
7″ Round 90° Elbow = 8 ft.
7″ Roof Cap = 30 ft.

DUCTING CHART–JV6 Series Models
Equivalent Length in Feet
400

0

25

50

75

Air Volume in CFM

•

•

350

•

•

•

300

•

150

7″ Round

•

•
•

250
200

31⁄4″ x 10″
Rectangular

31⁄4″ x 10″ Rectangular Transition to 6″ Round = 4.5 ft.
7″ Round 90° Elbow = 8 ft.
7″ Roof Cap = 30 ft.

MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of a 31⁄4″ x 10″ rectangular,
6″ or 7″ diameter round duct should not exceed 65 equivalent feet.

7

•

Installation Instructions
WORKSHEET – CALCULATE TOTAL EQUIVALENT DUCTWORK LENGTH
DUCT
PIECES

EQUIVALENT NUMBER
LENGTH
x USED
= TOTAL

31⁄4″ x 10″
Rect.,
straight

1 Ft.

7″ Round,
straight

1 Ft.

6″ Round,
straight

1 Ft.

31⁄4″ x 10″
Rect. 90°
elbow

8.5 Ft.

x (

)

=

Ft.

31⁄4″ x 10″
Rect. 45°
elbow

7 Ft.

x (

)

=

Ft.

31⁄4″ x 10″
Rect. 90°
flat elbow

24 Ft.

x (

)

=

Ft.

31⁄4″ x 10″
Rect.
wall cap
with
damper

45 Ft.
(7 ft. w/o
damper)

x (

)

=

Ft.

x (

)

=

Ft.

31⁄4″ x 10″
Rect. to
6″ round
transition

4.5 Ft.

x (

)

=

Ft.

31⁄4″ x 10″
Rect. to
6″ round
transition
90° elbow

11.5 Ft.

6″ Round,
90° elbow

8 Ft.

6″ Round,
45° elbow

6.5 Ft.

x (

x (
x (

x (

x (

x (

Subtotal column 1

)

)
)

)

)

)

=

=
=

=

=

DUCT
PIECES

Ft.

EQUIVALENT NUMBER
LENGTH
x USED
= TOTAL

6″ Round
wall cap
with
damper

34 Ft.
(6 ft. w/o
damper)

x (

)

=

Ft.

x (

)

=

Ft.

6″ Round
roof cap

30 Ft.

x (

)

=

Ft.

6″ Round
to
31⁄4″ x 10″
rect.
transition

5.5 Ft.

x (

)

=

Ft.

6″ Round
to
31⁄4″ x 10″
rect.
transition
90° elbow

14.5 Ft.

x (

)

=

Ft.

7″ Round,
90° elbow

8 Ft.

x (

)

=

Ft.

7″ Round,
45° elbow

6.5 Ft.

x (

)

=

Ft.

7″ Round
wall cap
with
damper

34 Ft.
(6 ft. w/o
damper)

x (

)

=

Ft.

x (

)

=

Ft.

Ft.

7″ Round
roof cap

30 Ft.

x (

)

=

Ft.

5.5 Ft.

x (

)

=

Ft.

Ft.

7″ Round
to
31⁄4″ x 10″
rect.
transition
7″ Round
to
31⁄4″ x 10″
rect.
transition,
90° elbow

14.5 Ft.

x (

)

=

Ft.

Subtotal column 2

=

Ft.

Subtotal column 1

=

Ft.

Total ductwork

=

Ft.

Ft.
Ft.

=

Ft.

=

Ft.

MAXIMUM DUCT LENGTH: For satisfactory air
movement, the total duct length of a 31⁄4″ x 10″
rectangular, 6″ or 7″ diameter round duct should
not exceed 65 equivalent feet.

8

Installation Instructions
DAMAGE – SHIPMENT/INSTALLATION

TOOLS YOU WILL NEED

• If the unit is damaged in shipment, return the unit to the
store in which it was bought for repair or replacement.
• If the unit is damaged by the customer, repair or
replacement is the responsibility of the customer.
• If the unit is damaged by the installer (if other than the
customer), repair or replacement must be made by
arrangement between customer and installer.

Flat blade and Phillips
screwdrivers

Saw (saber or keyhole)

MOUNTING SPACE

30″ or 36″

Bottom edge of
cabinet needs
to be 30″ or
more from
the cooking
surface

Pencil
Duct tape

Electric drill

Metal snips
(in some
applications)

1/4″ pivoting
hex socket

Pliers

Tape measure

Wire stripper

Flashlight

Caulking

Level

1/4″ Nutdriver

30″
min.

PARTS INCLUDED
66″ or more
from the floor
to the top of
the hood

PART

QUANTITY

Metal Grease Filters

2

Mounting Screws

4

Exhaust Adaptor
(for 31⁄4″ x 10″ rect. venting)

1

Exhaust Adaptor Screws

2

Exhaust Adaptor
(for 7” round venting)

1

Some parts are shipped in the hood behind the filters.
On some models, the bottom cover of the hood also
needs to be removed to gain access to the parts.

NOTES:
• This range hood is for installation over ranges up to
36″ wide.
• If you are going to vent your range hood to the outside,
see the “Ducting Requirements” section for exhaust
duct preparation.

9

Installation Instructions
1 CHOOSE VENT OPTION
The outside vent exhaust option that your installation
requires will determine the hood knockouts that you
will use.
If the hood is to be installed in a recirculating, nonvented ductless manner, do not knock out any vent
openings in the hood. Only an electrical access hole
will be knocked out of the hood.
NOTE: Only JV5 Series models may be recirculated.
We do not recommend the recirculated configuration
for JV6 Series models.
Determine the vent option that your installation will
require from the following choices:

A

Outside top exhaust
(Vertical duct–31⁄4″ x 10″ Rectangular)

B

Outside top exhaust
(Vertical duct–7″ Round)

10

C

Outside rear exhaust
(Horizontal duct–31⁄4″ x 10″
Rectangular)

D

Recirculating
(Non-vented ductless–Optional for
JV5 Series models only)

Installation Instructions
2 REMOVE EXHAUST ADAPTOR

5 REMOVE OTHER EXHAUST ADAPTOR

Remove the 7″ round exhaust adaptor from the top of
the hood. Set it aside along with its mounting screws.

Remove the 31⁄4″ x 10″ rectangular exhaust adaptor
from inside the hood. Set it aside along with its
mounting screws and parts bag. Depending on the
model, the exhaust adaptor will be located on the
left or right side.

7″ round
exhaust
adaptor

31⁄4″ x 10″
rectangular
exhaust adaptor

3 REMOVE FILTERS

Remove the shipping tape holding the metal grease
filters in place. Pull down on the filter tabs and lift the
filters out. Set them aside.

31⁄4″ x 10″
rectangular
exhaust adaptor

6 REMOVE WIRING COVER

On models so equipped, remove the wiring cover from
inside the hood. Set the cover and its mounting screw
aside.

Filters
Wiring
cover

4 REMOVE BOTTOM COVER

On models so equipped, remove the bottom cover
from the hood. Set the cover and its mounting screws
aside.

7 REMOVE WIRING KNOCKOUT

Remove either the top or the back wiring knockout as
needed and install an approved strain relief clamp.

Bottom cover
(held in place
with 2
screws)

Strain relief
clamp

11

Installation Instructions
10 FOR 31⁄4″ X 10″ RECTANGULAR

8 REMOVE DUCT KNOCKOUT(S)

If recirculating, non-vented ductless (optional for
JV5 Series models only), see note below and skip to
Step 12 D and proceed. We do not recommend the
recirculated configuration for JV6 Series models.
Using a flat blade screwdriver, remove the appropriate
duct knockout(s) from the top or back of the hood.

31⁄4″ x 10″ Rectangular
vertical discharge.
Remove top rectangular
duct knockout only.

DUCTED DISCHARGE
INSTALLATIONS ONLY:
Attach exhaust adaptor/damper over knockout
opening with two exhaust adaptor screws. Make sure
damper pivot is nearest to top/back edge of hood.
Remove tape from damper flap.

7 ″ Round vertical
discharge. Remove semicircular duct knockout and top
rectangular duct knockout.

Tape

Up to 1″ side-toside adjustment

Top/back edge

Pivot

Exhaust adaptor/damper
(vertical discharge position
shown)

NOTE: The exhaust adaptor/damper can be installed
up to 1 inch on either side of the hood center to
accommodate off-center ductwork. In extreme offcenter installations, one end of the duct connector may
need to be trimmed to clear the electrical cable clamp.

31⁄4″ x 10″ Rectangular
horizontal discharge. Remove
rear rectangular duct knockout only.

NOTE: If the hood is to be installed in a recirculating,
non-vented ductless manner, order kit number
WB02X10707 for 30″ hood models, or kit number
WB02X10708 for 36″ hood models. These kits can
be ordered from your GE supplier. Skip to Step 12 D
and proceed.

11 FOR 7″ ROUND VERTICAL

DUCTED DISCHARGE
INSTALLATIONS ONLY:
Re-install the 7″ round exhaust adaptor with its
screws, removed in Step 2 under the “Prepare the
Hood” section.

9 FOR HORIZONTAL DISCHARGE

INSTALLATIONS ONLY:
Remove the plate (on models so equipped) in front of
the horizontal discharge knockout. Cut the ties, lift
plate out, and discard plate. DO NOT REMOVE the
metal strip held in place with two screws.

Metal strip

7″ round
exhaust
adaptor

Ties

Screw

NOTE: The 7″ round exhaust adaptor can be installed
up to 1 inch on either side of the hood center to
accommodate off-center ductwork. In extreme off-center
installations, one end of the duct connector may need
to be trimmed to clear the electrical cable clamp.

Plate

12

Installation Instructions
D.Recirculating (non-vented ductless–
Available on JV5 Series models only)

12 MARK HOLES

Select the vent option that your installation will
require and proceed to that section:

• Use the hood as a template and mark the locations
on the cabinet for the electrical wiring and keyhole
screw slots.
• Since the hood is to be recirculated (not to be vented
outside), do not cut out any vent openings in the wall
or cabinet bottom.

A.Outside top exhaust
(Vertical duct–31⁄4″ x 10″ Rectangular)
• Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
Hood mounting screws (4)
1315⁄16″ (30″ hood)
1615⁄16″ (36″ hood)
Cabinet front

71⁄2″
Cabinet Bottom
51⁄4″
51⁄4″
5″

11⁄4″

Vertical duct
access hole

Wood shims (recessed-

Center
line

bottom cabinets only)

13 FOR RECESSED-BOTTOM

1315⁄16″ (30″ hood)
1615⁄16″ (36″ hood)

CABINETS ONLY

101⁄2″

2″

11⁄2″
Electrical access hole
(in cabinet bottom)

Wood shims

• If the cabinets have front, side or back trim, make 2
wood shims the width of the trim and attach them to
the cabinet bottom recess on both sides. See Step 12
for marking locations.

B.Outside top exhaust (Vertical duct–7″ Round)
• Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.

14 CUT HOLES

Hood mounting screws (4)
1315⁄16″ (30″ hood)
1615⁄16″ (36″ hood)

1315⁄16″ (30″ hood)
1615⁄16″ (36″ hood)

Cabinet front

71⁄2″

Cabinet
bottom

8″ DIA.
HOLE

Access
hole for 7″
round duct

Wood shims (recessedbottom cabinets only)

Cut holes at marked locations for duct and electrical
wiring. For the vertical duct, cut out 3/4″ extra
toward the front of the cabinet so you can move the
duct freely when installing the hood. It may also ease
installation by cutting the hole 101⁄2″ instead of 10″.

5″

Center
line

101⁄2″

2″

11⁄2″

Electrical access
hole (in cabinet bottom)

15 RUN WIRES

C.Outside rear exhaust
(Horizontal duct–31⁄4″ x 10″ Rectangular)

Run the electrical wires through the wall or
cabinet according to National Electrical Code
and applicable local codes.
NOTE: DO NOT turn the power on until
installation is complete.

• Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
Wood shims (recessed-bottom cabinets only)
1⁄8″
3⁄4″
Cabinet front

16 SCREW IN PARTWAY
33⁄4″

Cabinet
bottom

Drive a mounting screw (from the hardware packet)
partway into each center of the narrow neck of the
keyhole slots marked on the cabinet bottom.

Horizontal duct
access hole

51⁄4″

1315⁄16″ (30″ hood)
1615⁄16″ (36″ hood)

51⁄4″
71⁄2″
1315⁄16″ (30″ hood)
1615⁄16″ (36″ hood)

Hood mounting screws (4) Center line

17 FEED IN WIRES

Lift the hood into position and feed the house
wiring through the wiring knockout.

Electrical access hole
(in wall)

13

Installation Instructions
22 CONNECT WIRING

18 SECURE HOOD

Connect house black to hood black wire, house
white to hood white wire, and house ground under
green ground screw. Securely tighten the strain
relief clamp onto the house wiring.

Slide the hood back against the wall. Tighten
the mounting screws. Be sure the screw heads
are in the narrow neck of the keyhole slot.

Green ground screw

Mounting
screw (4)
Keyhole (4)

NOTE: DO NOT PUSH ON FAN BLADE. Pushing
on the blade may cause it to interfere with other
hood parts.

23 REPLACE WIRING COVER

On models so equipped, replace the wiring cover or
the bottom cover.

19 CONNECT DUCTWORK TO

HOOD
Use duct tape to make joints secure and air tight.

24 REPLACE FILTERS

Make sure fan blade turns freely. The installation is
complete. Turn on power at service panel, and test
for proper operation.

Duct tape

20 INSTALL LIGHT BULBS

Purchase and install two PAR20, 50 W maximum
halogen bulbs.

TROUBLESHOOTING CHECKLIST
If the hood seems to be operating at high speed when
the control is not set on high, or if ventilation seems
inadequate, check the following:
❏ Knockouts not removed from hood.
❏ Damper blade not opening.
❏ Reduced airflow because the duct is too small or the
duct length is too long.
❏ The duct is blocked.
❏ Undersized or restrictive wall or roof cap.

21 FOLLOW ELECTRICAL CODE

Complete the electrical wiring according to
National Electrical Code and local codes.
NOTE: This hood must be permanently grounded.
Connect house wiring (120 VAC) to hood wiring.

14

All warranty service provided by our Factory Service Centers
or an authorized Customer Care® technician. For service,
call 800-GE-CARES.

For The Period Of:

GE Will Replace:

One Year
From the date of the
original purchase

Any part of the range hood which fails due to a defect in materials or workmanship.
During this full one-year warranty, GE will also provide, free of charge, all labor and
in-home service to replace the defective part.

Safety Instructions

GE Range Hood Warranty

What GE Will Not Cover:
■ Replacement of house fuses or resetting of circuit
breakers.

■ Improper installation.

■ Damage to the product caused by accident, fire, floods
or acts of God.

■ Failure of the product if it is abused, misused, or
used for other than the intended purpose or used
commercially.

■ Incidental or consequential damage caused by possible
defects with this appliance.

This warranty is extended to the original purchaser and any succeeding owner for products purchased for home
use within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home.
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives
you specific legal rights, and you may also have other rights which vary from state to state. To know what your
legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Installation Instructions

Warrantor: General Electric Company. Louisville, KY 40225

Operating Instructions

■ Service trips to your home to teach you how to use
the product.

Customer Service

15

Safety Instructions

Service Telephone Numbers.
GE Answer Center ® 800.626.2000
The GE Answer Center® is open 24 hours a day, 7 days a week.

OR
Visit our Website at: www.geappliances.com

In-Home Repair Service 800-GE-CARES (800-432-2737)
Operating Instructions

Expert GE repair service is only a phone call away.

Special Needs Service 800.626.2000
800-TDD-GEAC (800-833-4322)
GE offers, free of charge, a brochure to assist in planning a barrier-free kitchen for persons
with limited mobility.

Installation Instructions

Service Contracts 800-626-2224
Purchase a GE service contract while your warranty is still in effect and you’ll receive a
substantial discount. GE Consumer Service will still be there after your warranty expires.

Parts and Accessories 800-626-2002
Individuals qualified to service their own appliances can have parts or accessories sent directly
to their homes (VISA, MasterCard and Discover cards are accepted).

Instructions contained in this manual cover procedures to be performed by any user. Other servicing
generally should be referred to qualified service personnel. Caution must be exercised, since
improper servicing may cause unsafe operation.

Customer Service

Service Satisfaction
If you are not satisfied with the service you receive from GE:

First, contact the people who serviced your appliance.
Next, if you are still not pleased, write all the details—including your phone number—to:
Manager, Customer Relations
GE Appliances
Appliance Park
Louisville, KY 40225

Printed in the United States

16



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Create Date                     : 2000:08:07 14:47:52
Producer                        : Acrobat Distiller 3.01 for Power Macintosh
Author                          : Johnson-Rauhoff
Creator                         : QuarkXPressª: LaserWriter 8 8.6.5
Title                           : 49-80025
Subject                         : GE-Broan Vented Range Hoods OM/II, JV535+7
Keywords                        : 164D3333P240, 49-80025, 626851A, 7-00 JR
Modify Date                     : 2000:08:07 14:55:38
Page Count                      : 16
Page Mode                       : UseOutlines
EXIF Metadata provided by EXIF.tools

Navigation menu