GE
Measurement & Control

High Resolution Weld Inspection and All-Purpose
Computed Radiography Scanner

Inspection Technologies:

CRxVision
Packed with innovative features to increase throughput, extend plate life
and provide excellent image quality, the CRxVision is designed specifically
for the inspection of welds. The scanner is developed to cover the stringent
ISO 17636-2 Class A and B requirements, as well as ASTM, ASME and EN
weld standards. Because of its versatility, it can also be used for many
other applications across the NDT industry.

CRxVision: the versatile, new tabletop scanner from GE.

6

Flexible

1

accepting a wide range of sizes, shapes and classes of imaging plates

Intuitive

2

no gain setting or photomultiplier adjustments required when
exposing various thicknesses

Fast

multiple plate scanning option: side-by-side and back-to-back
with a flat transport path

High Resolution

4

Extended Plate Life

5

new laser optics for profound reading and
higher data extraction

no mechanical handling of the imaging
plate during scanning and erasing

ASTM DICONDE Compliant

fully compatible with GE´s existing
Rhythm Software Platform

7
Ambient Operation

cover protects the imaging plate
from light exposure

3

8

Direct Laser Contact

the laser beam is in direct contact
with the imaging plate (no glass to
obscure data collection)

Your Benefits:
— Compliant to ISO 17636-2 Class A
and B, ASME, ASTM and EN weld
inspection standards.
— The CRxVision has an extremely wide
latitude eliminating the need for multiple
gain settings when exposing over a wide
range of thicknesses. This is the result of a
16 bit image processing at selectable
35 or 70 microns resolution.
— Exposure times for welds are equal or
better than existing film exposure times
(to comply with Code Standards like EN
and ASME) and can be reduced by up to
ten times for non-code type applications
like erosion/corrosion or valve placement.

— Designed for extremely high throughput:
90 plates/hr at 70 microns or 28 plates/hr
at 35 microns for a 10 x 40 cm (4.5 x 17”)
plate. The scanner allows multiple imaging
plates to be scanned simultaneously …
side-by-side and back-to-back as well as
various lengths to be scanned together.
This is a result of the straight and flat,
in-line scan and erase transport path.
— Ability to scan any shape or size of
imaging plate from from 20 to 1500 mm
(0.75 to 60”) in length. Imaging plates can
be exposed in any type of cassette, then
simply removed and inserted directly
into the scanner without the need of
any type of adapter, template or leader.

— A new innovative imaging plate design
now provides the GE CRxVision imaging
plates with more flexibility. This new
design allows each imaging plate the
ability to return to a flat state after being
constantly bent around pipes for the
inspection of welds. This feature also helps
improve productivity by allowing the
imaging plates to be easily extracted and
reinserted into cassettes.
— Plate transport through the scanners
is achieved by a magnetic transportation
system. This new combination of scanner
and imaging plate design allows the
imaging plate to be transported through
the scanner without any mechanical

handling of the phosphor ultimately
extending the overall life of the plate.
— The updated Rhythm RT software
simplifies inspection workflow. It now has
the ability to automatically crop the images
by detecting the physical edges of each
individual plate when they are processed.
Consequently, each individual plate can be
separately identified and saved or grouped
together and saved as one file.
— The new scanner enjoys all the
functionality offered by GE´s Rhythm
Software giving the inspector the ability
to view, enhance, measure, annotate and
comment on the images. The CRxVision

system is completely DICONDE compliant
and compatible with all existing modules in
GE´s Rhythm Software platform.
— The CRxVision can be used in ambient
light conditions with suitable handling as
the light cover protects the plates from light
exposure during the scan cycle. The cover
can be removed for work in darkrooms if
required.
— The scanner weighs less than 45 kg
(99 lbs) and has a footprint of 560 x 560 mm
(22 x 22 inches). It extends to 560 x 1280 mm
(22 x 50 inches) when the feed and exit
tables are attached.

— The light guide can be easily cleaned
with an internal brush which is operated
by simply turning a set screw. The eraser
section of the scanner is completely sealed
from the optics section to prevent migration
of any dust particles into the machine.

Applications
Even though the CRxVision was designed for the inspection of welds, it also has the
ability to cover a wide range of industrial radiography applications, from Oil & Gas
to Aerospace, and from Power Generation to General NDT.
•	 Weld inspection
•	 Erosion/Corrosion inspection (CUI, FAC, etc.)
•	 Castings (In-process and final)
•	 Valve positioning
•	 Concrete and Structure inspection
•	 Government (Arsenals, National Laboratories, Proving Grounds)
•	 Military (in-service aircraft, ships, etc.)

In all applications the CRxVision offers the following significant benefits of digital
radiography:
•	 No darkroom facilities/trucks needed
•	 Eliminate processing chemicals and chemical disposal/silver recovery
•	 Improved image interpretation and inspection quality level with Flash!FiltersTM
•	 Consistent & operator–independent results with the Automated WT Measurement tool
•	 High reduction in retakes due to the wide dynamic range of the imaging plates

Rhythm RT for Workflow Optimization

•	 No development time, as images are immediately available after scanning
•	 High reduction in storage space when archiving digital images
•	 Data management (trending) and data sharing advantages
•	 Fully DICONDE compliant

Both GE´s Rhythm RT and Rhythm RT Lite provide a powerful, ASTM DICONDE Compliant operational software platform, which
simplifies the overall inspection workflow.
After entering the component and technique data, select the
required scan resolution and then the scanner will prompt you to
insert the imaging plate. Once the imaging plate is scanned, the
image will appear and any Region of Interest (ROI) may then be

identified on the computer screen and enhancements,
annotations and measurements applied. The image can then be
saved for further review and/or storage. The files can be saved in
TIFF, BMP, JPEG, and/or DICONDE formats.

Rhythm RT workflow
the required
1 Select
resolution

2

5

Enter the component
and technique
information

Select a specific ROI
(if desired)

3

Insert the imaging
plate(s) to start the cycle

4

Press scan

6

Send image to review

Imaging Plates
Four different types of imaging plates with a ferromagnetic
back layer have been developed specifically for the CRxVision.
This allows the imaging plates to be magnetically transported
through the scanner with no phosphor touch points. In addition,
this new design helps reduce backscatter which improves the
overall quality of the image as well as allows the imaging plate
the ability to return to a flat position after being constantly bent
around curved objects.
GE´s four imaging plate types are as follows:
•	 IPC2: Standard Resolution & High Speed - for general purpose

Technical Specifications of CRxVision
Functional Data

Electrical Data

Principle

Operating voltage

Eraser

High performance table-top flatbed scanner with
contactless plate transport
Inline

Mains frequency

Auto-ranging external power supply from
100 V to 240 V, DC Output 24V
50/60 Hz

Resolution

Standard resolution (SR) 70 µm

Mains fuse protection

Europe

min. 10 A, max. 16 A

USA & Japan

min. 10 A, max. 15 A

High resolution (HR)

35 µm

Maximum basic

Standard resolution (SR) 80 µm (6,25 LP / mm)

Spatial resolution

High resolution (HR)

40 µm (12,5 LP / mm)

•	 IPS: High Resolution & Medium Speed - for inspection of welds

Scan width

35 cm (14 inch)

•	 IPS2: High Resolution & Medium Speed – for inspection of welds
Excellent for very low contrast, homogeneity type applications
and premium weld quality inspections.

Throughput
(10 x 40 cm
4.5 x 17”)

Standard resolution (SR) 90 plates/hour

•	 IPU: Extreme High Resolution & Slow Speed - for extremely high
resolution applications when very low micron range sensitivity
is required.

Time to image
(in Rhythm RT)

Standard resolution (SR) 40 sec

Plates are available in various size formats ranging from 70 mm
(2.76”) wide to 1500 mm (60”) in length.

LUT
(look up table)
Bit depth

Linear
(native Square root)

Dimensions

Scanner

Weight

Scanner including I/O
table and light cover
Scanner

Interfaces

Scanner including I/O
table and light cover
Ethernet, RJ45

Protective Cassettes
A range of flexible and hard cassettes are also available. Both
versions may be supplied with or without lead, depending on
the application.

High resolution (HR)

High resolution (HR)

28 plates/hour

147 sec

16 Bit
56 x 56 x 47 cm
(22” x 22” x 19”)
128 x 56 x 47 cm
(52” x 22” x 19”)
45 kg (99 lbs)

ASME

ASME Code Section V Article 2

ISO 17636-2

Class A / Class B
(in defined exposure
conditions)
IPS, IPS-2: 1/80,
IPU: 1/40
IPS, IPS-2: S/80,
IPU: S/40

EN2446-06

I/O Table with light cover

Long I/O table
Flight Case

High speed plate

Operation

IPS

High resolution

IPS2

High resolution

IPU

Extremely high
resolution (X-ray)

Transport

Mechanical
conditions for
transport
Shock
specifications

In packaging

IEC TR 60721-4-5 (1997):
class 5M2

Certified by BAM

Imaging Plates
IPC2

15 °C to 35 °C
(59 °F to 95 °F)
Relative humidity
15% to 80%
(non condensed)
Magnetic field
Compliant with
EN 61000-4-8, Level 2
IEC721-3-2 (1997): class 2K2 and 2M3, with
following restrictions
Temperature
-25 °C to +55 °C
(-13 °F to 131 °F)
Vibration
5 to 200 Hz
(vertical, longitudinal,
transversal axis)
In packaging
IEC 721-3-2 (1997):
class 2M2

Certified by BAM

Quick mountable, stainless steel, input/output
table set with 43 cm (17”) tray length and light
cover for input side
Input/output extension for long plates scanning
150 cm (59”)
Robust Flight Case with shock-absorbers, wheel,
ruggedized handles and compartments for I/O
tables, laptop, accessories

Environmental Conditions
Temp. allowed

Verified with X-ray,
Ir-192, Se-75, Co-60

Accessories

50 kg (110 lbs)

CE, UL (NRTLus), cUL (cNRTLus), C-Tick, Customs
Union Mark

Standby
max. 22 W
110 V - 240 V / 50-60 Hz
During operation
max. 140 W
110 V - 240 V / 50-60 Hz (absolute peak)

Application Compliance

EN14784-1

DC voltage, coded 8-pin, female
Certifications

Power
consumption

Use: CRxVision can scan
any shape or size
imaging plate from 20
to 1500 mm (0.75 to 60”)
in length.

Cassettes
Flexible cassettes

PVC or vinyl envelopes

different sizes

Hard cassettes
(for defined exposure conditions)

35 x 43 cm, 20 x 24 cm, 24 x 30 cm, 15 x 30 cm
14” x 17”, 8” x 10”, 10” x 12”, 6” x 12”

Regional Offices
Europe

Americas

Asia

Germany
Niels-Bohr-Str. 7
31515 Wunstorf
P.O. Box 6241
31510 Wunstorf
+49 5031 172 0

United States
50 Industrial Park Road
Lewistown, PA 17044
+1 866 243 2638 (toll free)
+1 717 242 0327

China
5F, Building 1, No.1 Huatuo Road,
Zhangjiang High-Tech Park,
Shanghai 201203
+86 800 915 9966 (toll-free)
+86 (0) 21-3877 7888

Bogenstr. 41
22926 Ahrensburg
+49 4102 807 117

201 Beltway Green
Pasadena, Texas 77503
+1 855 232 7470

Belgium
Roderveldlaan 5
2600 Berchem
+32 3 456 2820
United Kingdom
Fir Tree Lane
Groby LE6 0FH
+44 845 601 5771
France
68, Chemin des Ormeaux
Limonest 69760
+33 47 217 9216
Spain
San Maximo, 31, Planta 4A, Nave 6
Madrid 28041
+34 915 500 59 90

Brazil
Av. Maria Coelho Aguiar, 215
Building C, 6th floor
Jd. Sao Luiz - Sao Paulo - SP
CEP 05804-900 – Brazil
+55 11 3614-1840

Unit 1602, 16/F Sing Pao Building
101 King’s Road
North Point
Hong Kong
+852 2877 0801
Japan
Harumi Island Triton Square Office Tower X
1-8-10, Harumi, Chuo-ku, Tokyo 104-6023
Tel: +81 3 6890 4567
Fax: +81 3 6864 1738

GE has sales and service offices all over the world.
Below are some of our locations. Visit www.ge-mcs.com for a complete listing.
•	
•	
•	
•	
•	
•	
•	

Alzenau, Germany
Burford, United Kingdom
Moscow, Russia
Bucharest, Romania
Prague, Czech Republic
Stockholm, Sweden
Milan, Italy

•	
•	
•	
•	
•	
•	
•	
•	

East Perth, Australia
Singapore
Dubai, UAE
Buenos Aires, Argentina
Mexico City, Mexico
Airdrie, Alberta, Canada
Toronto, Ontario, Canada
Montreal, Quebec, Canada

www.ge-mcs.com/x-ray
GEIT-40058EN (06/14)

© 2014 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names
mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2014:06:13 10:26:48+02:00
Creator                         : Adobe InDesign CS6 (Macintosh)
Modify Date                     : 2014:06:17 10:37:20+02:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2014:06:17 10:37:20+02:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Instance ID                     : uuid:d8253ec7-85ca-4af3-befa-0a29de2182b0
Original Document ID            : xmp.did:9AD8F01F9C21681188C6EC8277B92467
Document ID                     : xmp.id:CDD5CE4D642168118083A84262E1F8D9
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:FA637E996A256811822ADB8D6D0ADE77
Derived From Document ID        : xmp.did:FA637E996A256811822ADB8D6D0ADE77
Derived From Original Document ID: xmp.did:9AD8F01F9C21681188C6EC8277B92467
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2014:06:13 10:26:48+02:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 5
EXIF Metadata provided by EXIF.tools

Navigation menu