Ge Appliances Gp5 Data Sheet Indoor Lighting Fixtures High Bay GPE GHB Prismatic Luminaire |

Ge-Gp5-Data-Sheet-649363 ge-gp5-data-sheet-649363

2015-08-07

: Ge-Appliances Ge-Gp5-Data-Sheet-649363 ge-gp5-data-sheet-649363 ge-appliances pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

I-28/2008
Most commonly ordered
GE Lighting Solutions 1-888-MY-GE-LED www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
GPE GHB® PRISMATIC LUMINAIRE (Acrylic)
NuVation™ Electronic Ballast — High Bay, Open —
Bracket Mount Optical Series, General Die-Cast Housing
APPLICATIONS
Assembly lines, inspection areas, production bays, storage areas, warehouses and commercial areas
1598 Listed
Suitable For Damp Locations
Nuvation electronic ballast:
Dimming Option — dims lamp to 50% of rated
lamp wattage.
Two piece heavy-duty die cast aluminum
housing
Flexible Spacing Criterion (SC)–ve position
mounting bracket allows eld-adjustable light
distribution
Attractive round ballast housing design with
white polyester paint nish
Integral air gap between optical
mounting and ballast for optimum
temperature control and thermal
management
Slide-on mounting box adaptor with
3/4-in pendant and thru feed capability
for ease of installation and mounting.
External wattage selection port for
selection of 250, 320, 350 & 400 watt
choices.
Safety chain provisions
Mogul base socket – E39 standard
Shipped as components: Ballast, Optical.
Magnapack available for ballast.
SPECIFICATION FEATURES
ORDERING NUMBER LOGIC
GPE
PRODUCT
IDENT
XXX
W
COLOR
X
40
WATTAGE
XX
M
LIGHT
SOURCE
X
0
VOLTAGE
X
E
BALLAST
TYPE
X
V6
OPTICAL
CODE
XX
NA
PHOTOMETRY
CODE
XX
11
MOUNTING
CODE
XX
GPE =
GHBP
Luminaire
with
NuVation
Electronic
Ballast
W = White
Polyester
Powder
25 = 250
32 = 320
35 = 350
40 = 400
N = Ballast
will operate
Pulse Start
or Ceramic
Metal Halide
Lamps
Note: Lamp
is vertical
base up.
Lamp not
included.
G =
208-277
Discrete
voltages
must be
specied
when
ordering
cord
& plug
assemblies:
2 = 208
3 = 240
4 = 277
E = Elec-
tronic
C=
Dimming
V4 = Open
ventilated
14-inch glass
D4 = 14-inch
glass with door
glass kit
V6 = Open
ventilated
16-inch acrylic
NA = Not
Applicable
(Reector
position is
set at
installation)
See opposing
page.
XX = Select Code Below
11 = Pendant mounting
13 = Provision for Slide-on Primary Electrical
Disconnect. Order TWOBP Box (Thru Feed
Capability Only) Separately.
14 = Provision for Slide-on Primary Electrical
Disconnect. (Pendant and Thru Feed
Capability) Order PED Box Separately
15 = Prewire with Loop, Cord and Plug Part
of “Power Hook”. Order Receptacle/Hook
Box Separately. (Not CSA/CUL)
31 = Prewire with Hook, 3-ft (0.9 Meters) #16/3
Cord, and Nema Plug
33 = Prewire with Loop, 3-ft (0.9 Meters) #16/3
Cord, and Nema Plug (Order locking
receptacle hook box separately.)
MODULAR PREWIRE
41 = ACS with 3-ft (0.9 meter) cord & Hook
69 = ACS with 6-ft (1.8 meter) cord & Hook
43 = ACS with 3-ft (0.9 meter) cord & Loop
70 = ACS with 6-ft (1.8 meter) cord & Loop
PLUG-N-GO
51 = Plug-N-Go with 3 ft. (0.9 meter) Cord & Hook
71 = Plug-N-Go with 6 ft. (1.8meter) Cord & Hook
53 = Plug-N-Go with 3 ft. (0.9 meter) Cord & Loop
72 = Plug-N-Go with 6 ft. (1.8 meter) Cord & Loop
Note: ACS = Flex 3+
Plug-N-Go = FSC Series
Q = Auto-
matic Switch
Quartz
S = Exclusionary
mogul base
socket
for MH open
xtures
NOTE: Do not use open opticals
with lamps specied for use in
enclosed xtures only.
Note: Lens assemblies’
available.
V2 = Open ventilated
22-inch acrylic
Exclusionary base socket is available for use with Metal Halide lamps in open xtures to comply with
NEC 2005 regulations (GELS “S” Option).
Customer should consult or review local electrical codes for compliance.
BALLAST DATA
* 13% Improvement in Pulse Start Metal Halide lamp lumen maintenance vs. magnetic.
* 6% improvement in Ceramic Metal Halide lamp lumen maintenance vs. magnetic.
* 50% lower ballast losses than typical CWA magnetic HID ballast.
* Lamp wattage regulation of +/-2% change for +/-10% change in line voltage.
* Ballast is rated for use with voltage range between 208 and 277 with +/-10% line voltage tolerance,
50/60 Hz, and will automatically sense voltage within specied range.
* Ballast input current total harmonic distortion (THD) of less than 15% when operated at nominal line
voltage.
* Ballast is thermally protected to shut o when operating temperatures are
above unacceptable levels for the ballast safe and reliable operation.
* Ballast has an end-of-lamp-life detection and shutdown circuit.
* The ballast shall have a minimum starting temperature of –20 degrees F
and maximum operating ambient of 55 degrees C..
* Ballast is capable of operating pulse start metal halide or ceramic metal halide lamp types.
* Five-Year Fixture Failure Warranty.
* Meets requirements of FCC rules and regulations, Title 47 CFR part 18 for nonconsumer equipment.
Dimming Ballast
* The ballast is supplied with a violet (+) and gray (-) wire for dimming control connections.
* Ballast dims to fty percent of rated lamp wattage.
* Dimming voltage is 0-10V where 10V is high wattage and 0 is fty percent of rated lamp wattage.
* Ballast operates the lamp at high wattage for 15 minutes at start up.
*
Ballast operates lamp at high wattage for fteen minutes after operating in dim mode for twenty-four hours.
Lamp Line Input
Wattage Voltage Watts
400 277 428
400 240 432
400 208 435
350 277 377
350 240 380
350 208 383
320 277 346
320 240 347
320 208 349
250 277 276
250 240 272
250 208 271
INPUT WATTAGE TABLE
All Electronic devices are susceptible to transient voltage spikes. For facilities where the lighting circuits
are not protected from transient voltage spikes a (TVSS) Transient Voltage Surge Suppression system
is recommended. To protect the NuVation ballast a TVS protection system must be able to suppress a
3000V ring wave as described in ANSI/IEEE C62.41 B1.
X
OPTIONS
X
2008/I-29
GE Lighting Solutions 1-888-MY-GE-LED www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
E*L2-
E*L6-
GPE GHB ® PRISMATIC LUMINAIRE (Acrylic)
NuVation Electronic Ballast
High Bay, Open — Bracket Mount Optical Series
General Die-Cast Housing
NOTES
See explanation on “Optical Flexibility” Page I-5. See
References.
REFERENCES
See Page I-104 for start of Accessories.
See Page I-117 for Component Ordering Logic.
See Page I-129 for Explanation of Options and Other
Terms Used.
FIXTURE DIMENSIONS
EAL2-GHBP
Clear acrylic lens for 22-in. (559mm) optical
(40°C max. ambient on 400 watt xtures)
EAL6-GHBP
Clear acrylic lens for 16-in (406mm) optical
(40°C max. ambient on 250 watt xtures)
EAPL2-GHBP
Clear acrylic prismatic conical lens for 22-in (559mm) optical
(40°C max. ambient on 400 watt xtures)
EAPL6-GHBP
Clear acrylic prismatic conical lens for 16-inch optical
(40°C maximum ambient on 250W xtures)
EARL6-GHBP
Clear prismatic drop lens for 16-inch optical
(40°C maximum ambient on 250W xtures)
E*RL6-
E*PL2-
E*PL6-
Lens Assemblies
For Acrylic/Polycarbonate opticals only (Order separately)
Note 1: For Advanced “ST” HID Acrylic, use corresponding Acrylic Photometry
Code listed in Photometric Section and associated photometric data.
Note 2: See page T-34 for Alternative Material explanation.
V22A - 26.25 - 28.25 in. Dia.
(667- 718mm)
V22A - 22.500 in. (572mm) Dia.
3/4 in. NPSC
Thread
15.00 in. Dia.
(381mm)
1/2 in. (TYPICAL)
DATA
Approximate Net Weight lbs kgs
Ballast and Optical 22-32 10-15
PHOTOMETRIC SELECTION TABLE
D4 OPTICAL - Enclosed & Ventilated 14in. Prismatic Glass Reector with Flat Glass Lens
Light Max Spacing Reect. Photometric Optical Photometry
Wattage Source Temp Criteria Position Curve Code Code
350,400 MH,P 55 1.5 9 450161 V4 NA
350,400 MH,P 55 1.8 7 450159 V4 NA
350,400 MH,P 55 2.0 5 450157 V4 NA
350,400, Coated
MH,P 55 1.3 8 450169 V4 NA
350,400, Coated
MH,P 55 1.5 6 450167 V4 NA
350,400, Coated
MH,P 55 2.0 2 450163 V4 NA
250 HPS 55 1.5 3 450175 V4 NA
250 HPS 55 1.8 2 450177 V4 NA
400 HPS 55 1.7 2 450153 V4 NA
250, 320 (ED28)
MH, P 55 1.4 2 450196 D4 NA
250, 320 (ED28)
Coated MH, P 55 1.3 2 450207 D4 NA
350,400, Coated
MH, P 55 1.3 9 450190 D4 NA
350,400, Coated
MH, P 55 1.7 5 450187 D4 NA
350,400, Coated
MH, P 55 1.9 3 450185 D4 NA
350, 400 MH,P 40 2.0 3 179381 V6 NA
350, 400, Coated
MH,P 40 1.9 3 179382 V6 NA
250 HPS 55 1.7 4 178415 V6 NA
250 HPS 55 1.9 5 178413 V6 NA
250 MH, P 40 1.5 4 179274 V6 NA
250 MH, P 40 1.7 5 179271 V6 NA
250, Coated MH, P 40 1.5 4 179273 V6 NA
250, Coated MH, P 40 1.7 5 179272 V6 NA
175 MH, P 40 1.5 3 450246 V6 NA
175 MH, P 40 1.7 4 450247 V6 NA
175 MH, P 40 2.0 5 450248 V6 NA
175, Coated MH, P 40 1.5 3 450226 V6 NA
175, Coated MH, P 40 1.7 4 450229 V6 NA
175, Coated MH, P 40 1.9 5 450232 V6 NA
250 MH, P 40 1.5 3 450237 V6 NA
250 MH, P 40 1.7 4 450238 V6 NA
250 MH, P 40 2.0 5 450239 V6 NA
250, Coated MH, P 40 1.4 3 450217 V6 NA
250, Coated MH, P 40 1.6 4 450220 V6 NA
250, Coated MH, P 40 1.8 5 450223 V6 NA
** Ordered separately
* Select Lens material (Example EAL2-GHBP = Standard Acrylic)
V4 OPTICAL - Open & Ventilated 14in. Prismatic Glass Reector
MH requires “S” option EX39 base socket
V6 OPTICAL - Open & Ventilated 16in. Acrylic Prismatic Reector
MH requires “S” option EX39 base socket
V6 OPTICAL - Ventilated 16in. Acrylic Prismatic Reector with E*L6-GHBP Flat Polymeric Lens**
MH requires “S” option EX39 base socket
V6 OPTICAL -
Ventilated 16in. Acrylic with E*PL6-GHBP Prismatic Conical Polymeric Lens**
MH requires “S” option EX39 base socket
PHOTOMETRIC SELECTION TABLE
Light Max Spacing Reect. Photometric Optical
Photometry
Wattage Source Temp Criteria Position Curve Code Code
250 MH, P 40 1.3 3 450240 V6 NA
250 MH, P 40 1.5 4 450241 V6 NA
250 MH, P 40 1.7 5 450242 V6 NA
250, Coated MH, P 40 1.2 3 450218 V6 NA
250, Coated MH, P 40 1.4 4 450221 V6 NA
250, Coated MH, P 40 1.6 5 450224 V6 NA
V6 OPTICAL - Ventilated 16in. Acrylic with E*RL6-GHBP Drop Polymeric Lens**
MH requires “S” option EX39 base socket
250, 320 (ED28)
MH, P 55 0.8 5 451942 V2 NA
250, 320 (ED28)
Coated MH 55 1.0 5 451943 V2 NA
350,400 MH, P 55 1.5 5 451948 V2 NA
350,400, Coated MH 55 1.4 5 451949 V2 NA
400 HPS 55 0.9 4 451954 V2 NA
400 HPS 55 1.2 5 451955 V2 NA
V2 OPTICAL - Open & Ventilated 22in. Prismatic Acrylic Reector
MH requires “S” option EX39 base socket
V2 OPTICAL - Ventilated 22in. Prismatic Acrylic Reector with E*PL2-
GHBP Prismatic Conical Polymeric Lens**
MH requires “S” option EX39 base socket
** Ordered separately
* Select Lens material (Example EAL2-GHBP = Standard Acrylic)
250, 320 (ED28)
MH, P 40 1.0 3 451946 V2 NA
250, 320 (ED28)
Coated MH 40 1.0 3 451947 V2 NA
350,400 MH, P 40 1.5 4 451952 V2 NA
350,400 Coated MH 40 1.5 5 451953 V2 NA
250, 320 (ED28)
MH, P 40 0.8 5 451944 V2 NA
350,400 MH, P 40 1.5 4 451950 V2 NA
350,400, Coated
MH 40 1.4 5 451951 V2 NA
V2 OPTICAL - Ventilated 22in. Prismatic Acrylic Reector with E*L2-GHBP
Flat Clear Polymeric Lens**
MH requires “S” option EX39 base socket

Navigation menu